Amendment_4_Attachment_2_Equip_List_revised.xls
XLS spreadsheet 119 KB Posted
- Solicitation number
- SP3300-16-Q-0195
- Issued by
-
Defense Logistics Agency Distribution
About this file
Amendment 0004 Revised Attachment 2 - Equipment Inventory List
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment_4-Attachment_1_-_PWS-16Q0195.docx | DOCX document | |
| Amendment_4_SP330016Q0195.pdf | ||
| Amendment_3_SP330016Q0195.pdf | ||
| Amendment_2_SP330016Q0195.pdf | ||
| Amendment_1_SP330016Q0195.pdf | ||
| Attachment_8_Certification_of_Offeror_Accounting_System_16Q0195.doc | DOC document | |
| Attachment_5-TE_1.1__Contractor_Personnel_Security_.docx | DOCX document | |
| Attachment_7_Schedule_of_Supplies-16Q0195.xlsx | XLSX spreadsheet | |
| Attachment_2_-_Equipment_List.xls | XLS spreadsheet | |
| Attachment_9-Past_Performance_Questionnaire_16Q0195.docx | DOCX document | |
| RFQ_SP330016Q0195.docx | DOCX document | |
| Attachment_4_DoL_Wage_16Q0195.pdf | ||
| Attachment_1_-_PWS-16Q0195-FBO.docx | DOCX document | |
| Attachment_3_-Maint_Task_List.docx | DOCX document | |
| Attachment_6-_TE_1.2_CAC_Procedures.docx | DOCX document |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BLDG. 110 DDJF JACKSONVILLE, FL
| Bldg. # | Floor | Room/Zone | Category | Type of Device | Device Manufacturer or ID | Devices | Periodicity of PMS | |
| BLDG 110 | ||||||||
| 110 | 1 | FRONT ADMIN DOOR | ACS | Door Group | LENEL | CAC reader, BMS, A- phone /w camera, mag lock Rex release and motion release | Qtrly | |
| 110 | 1 | Security officer | ACS | Door Group | LENEL | CAC reader, BMS, motion release, elec. Striker and a-phone | Qtrly | |
| 110 | 1 | IT's door to warehouse | ACS | Door Group | LENEL | CAC reader, BMS, release motion and Elec. Striker | Qtrly | |
| 110 | 1 | Side Admin Door | ACS | Door Group | LENEL | CAC reader, A-phone, BMS, motion sensor and elec.striker | Qtrly | |
| 110 | 1 | Rear Admin Door | ACS | Door Group | LENEL | CAC reader, BMS, Striker, Motion release | Qtrly | |
| 110 | 1 | Post one guard office | ACS | Comm | LENEL/Pelco/A-phones | Base station for five a-phones, Pelco DVR, smart sight video severs, Pelco matrix, Nisca badging equipment, enterasys etherant switches (power supply for cameras), (2) CAC readers, elec door striker, BMS, release motion and Dell sever, lenel on guard system, several cctv monitors, 3 remote buttons to open/closed gates and the Lenel On-Guard sever. | Qtrly | |
| 110 | 1 | Duress system | ACS | Door Group | in overhead West wall inside of Admin area | Qtrly | ||
| 110 | 1 | Duress buttons | ACS | Door Group | Director, Deputy, and Guard office | Qtrly | ||
| 110 | 1 | A-PHONES | COMMS | COMMS | Director, Deputy, Security office, Guard office (master for gates entrance) , Transportation office, Safety and Receptionist Desk (master) | Qtrly | ||
| 110 | 1 | Key System | ACS | Global Facilities Management | ||||
| System App (GFMS) | Key System Inc | On east wall outside of the guard office | Qtrly | |||||
| 110 | 1 | Lobby | A-phone | Camera | A-Phone | 1st floor lobby | Qtrly | |
| 110 | 1 | vehicle gate 1 | A-phone | Camera | A-Phone | a-phone/w camera and (2) Cac readers. | Qtrly | |
| 110 | 1 | vehicle gate 4 | A-phone | Camera | A-Phone | a-phone/w camera and (2) Cac readers. | Qtrly | |
| 110 | 1 | vehicle gate13 | A-phone | Camera | A-Phone | a-phone/w camera and (2) Cac readers. | Qtrly | |
| 110 | 1 | pedestrian gate | A-phone | Camera | A-Phone | a-phone/w camera,Maglock and (2) Cac readers. | Qtrly | |
| 110 | 1 | Lan Room | ACS | RTV/SMP Panels | LENEL/AMAG Panels | Lenel and AMAG boards with batteries, motion sensor, (3) BMS, Lenel keypad, CAC reader, elec. Door strike, arm/disarm light and Altronix batteries back-up system | Qtrly | |
| 110 | 1 | Over head door 8 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 110 | 1 | Over head door 9 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 110 | 1 | Personnel Door 9B | ACS | Door Group | Lenel | Elec. Striker, BMS, Card Reader and Motion | Qtrly | |
| RTV/ SMP Panels 9B | COMM | Control Panel | Lenel | RTV/SMP Panels for Lenel circuit boards and back-up batteries. Area two | ||||
| 110 | 1 | Overhead Door 10 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 110 | 1 | Overhead Door 10 | CCTV | PTZ Camera | Pelco | PTZ camera (inside the door),BMS | Qtrly | |
| 110 | 1 | Overhead Door 3 | CCTV | PTZ Camera | Pelco | PTZ camera (inside the door) BMS | Qtrly | |
| 110 | 1 | Outside door 3 | CCTV | fixed camera | Honeywell | Fixed camera with 2 monitors inside of warehouse with 2 remote button to open overhead door. | ||
| 110 | 1 | Overhead Door 3 | ACS | Door Group | Lenel | BMS"s | ||
| 110 | 1 | Personnel Door 10B | ACS | Door Group | Lenel | BMS inside PPP&M Admin office | Qtrly | |
| 110 | 1 | Overhead Door 3B | ACS | Door Group | Lenel | CAC reader, BMS, and Elec. Striker | Qtrly | |
| 110 | 1 | RTV / SMP panels 3B | comm | Control Panel | Lenel | RTV/ SMP Panels for Lenel circuit boards and batteries. Area 4. | ||
| 110 | 1 | FLC IT's door | ACS | Door Group | Lenel | BMS (Door is FLC IT"s that open into our space, right beside H-13 column) | Qtrly | |
| 110 | 1 | Emergency gate (east side) | ACS | Door Group | Lenel | Claw lock, BMS and emergency release | ||
| 110 | 1 | Roof cameras | CCTV | PTZ Camera | Pelco | Three roof cameras | Qtrly | |
| BLDG 109 | ||||||||
| 109 | 1 | Personnel door | ACS | Door Group | LENEL | Cac Reader, Elec. Striker, BMS | Qtrly | |
| 109 | 1 | Overhead Door 1 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 109 | 1 | Overhead Door 2 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 109 | 1 | Personnel door 3 | ACS | Door Group | LENEL | BMS | Qtrly | |
| 109 | 1 | RTV Panel | COMM | Control Panel | LENEL | Lenel circuit boards- back up batteries | Qtrly | |
| 109 | 1 | South End of 109 | ACS | Reader | LENEL | Cac Reader for time keeping | Qtrly | |
| BLDG 163 | ||||||||
| 163 | 1 | Overhead Door 1 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 163 | 1 | Personnel Door 2 | ACS | Door Group | LENEL | BMS and audio siren | Qtrly | |
| 163 | 1 | Overhead Door 3 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 163 | 1 | Overhead Door 4 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 163 | 1 | Personnel Door 5 | ACS | Door Group | LENEL | BMS and Sensor | Qtrly | |
| 163 | 1 | Overhead Door 6 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 163 | 1 | Overhead Door 7 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 163 | 1 | Personnel Door 8 | ACS | Door Group | LENEL | CAC reader,elec.striker,BMS | Qtrly | |
| 163 | 1 | RTV/SMP Panels | COMM | Control Panels | Lenel | Lenel circuit boards and batteries | Qtrly | |
| 163 | 1 | Overhead Door 9 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 163 | 1 | Overhead Door 10 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 163 | 1 | Personnel Door 11 | ACS | Door Group | LENEL | BMS and audio siren | Qtrly | |
| 163 | 1 | Overhead Door 12 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 163 | 1 | Overhead Door 13 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 163 | 1 | Overhead Door 14 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 163 | 1 | Personnel Door 15 | ACS | Door Group | LENEL | BMS and audio siren | Qtrly | |
| 163 | 1 | Overhead Door 16 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 163 | 1 | Overhead Door 17 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 163 | 1 | Overhead Door 18 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 163 | 1 | Overhead Door 19 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 163 | 1 | Personnel Door 20 | ACS | Door Group | LENEL | BMS and audio siren | Qtrly | |
| 163 | 1 | Overhead Door 21 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 163 | 1 | Overhead Door 22 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 163 | 1 | Overhead Door 23 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 163 | 1 | Personnel Door 24 | ACS | Door Group | LENEL | BMS and audio siren | Qtrly | |
| 163 | 1 | Overhead Door 25 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 163 | 1 | Overhead Door 26 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| Bldg. 164 | ||||||||
| 164 | 1 | Overhead Door 1 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 164 | 1 | Personnel Door 2 | ACS | Door Group | Lenel | BMS and audio siren | Qtrly | |
| 164 | 1 | Overhead Door 3 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 164 | 1 | Overhead Door 4 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 164 | 1 | Personnel Door 5 | ACS | Door Group | Lenel | BMS Sensor and elec striker | Qtrly | |
| 164 | 1 | Overhead Door 6 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 164 | 1 | Overhead Door 7 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 164 | 1 | Personnel Door 8 | ACS | Door Group | Lenel | Mag Lock, Siren and BMS | Qtrly | |
| 164 | 1 | RTV/SMP PANELS | Comm | Control Panels | Lenel | Lenel Panel circuit boards and batteries. | Qtrly | |
| 164 | 1 | Overhead Door 9 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 164 | 1 | Overhead Door 10 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 164 | 1 | Personnel Door 11 | ACS | Door Group | Lenel | CAC reader, Sensor, Elec. Striker and BMS | Qtrly | |
| 164 | 1 | Overhead Door 12 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 164 | 1 | Overhead Door 13 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 164 | 1 | Overhead Door 14 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 164 | 1 | Overhead Door 15 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 164 | 1 | Personnel Door 16 | ACS | Door Group | LENEL | BMS and audio siren | Qtrly | |
| 164 | 1 | Overhead Door 17 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 164 | 1 | Overhead Door 18 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 164 | 1 | Overhead Door 19 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 164 | 1 | Personnel Door 20 | ACS | Door Group | LENEL | BMS and audio siren | Qtrly | |
| 164 | 1 | Overhead Door 21 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 164 | 1 | Overhead Door 22 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 164 | 1 | Overhead Door 23 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 164 | 1 | Personnel Door 24 | ACS | Door Group | LENEL | BMS and audio siren | Qtrly | |
| 164 | 1 | Overhead Door 25 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 164 | 1 | Overhead Door 26 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 164 | 1 | Personnel Door 27 | ACS | Door Group | Lenel | CAC reader, Elec. Striker and BMS | Qtrly | |
| 164 | 1 | Personnel Door 27A | ACS | Door Group | Lenel | BMS | Qtrly | |
| BLDG 171 | ||||||||
| 171 | 1 | RTV Panels | COMM | Control Panel | LENEL | (2) Lenel panels for circuit boards with batteries | Qtrly | |
| 171 | 1 | Vehicles gate camera | CCTV | PTZ Camera | Pelco | Pelco PTZ by door 1 . | Qtrly | |
| 171 | 1 | Vehicles gate | ACS | Door Group | LENEL | 2 Cac readers | Qtrly | |
| 171 | 1 | Personnel Door 1 | ACS | Door Group | Lenel | BMS- Audio siren | Qtrly | |
| 171 | 1 | Overhead Door 2 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 171 | 1 | Personnel Door 3 | ACS | Door Group | Lenel | BMS- Audio Siren | Qtrly | |
| 171 | 1 | Overhead Door 4 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 171 | 1 | Storage manager office | ACS | Door Group | Lenel | CAC Reader, mag lock,BMS Emergency release button | Qtrly | |
| 171 | 1 | Personnel Door 4A | ACS | Door Group | Lenel | BMS- Audio Siren | Qtrly | |
| 171 | 1 | Personnel door 4B | ACS | Door Group | LENEL | CAC Reader, BMS and electrical striker | Qtrly | |
| 171 | 1 | Overhead Door 5 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 171 | 1 | RTV / SMP Panels | COMM | Control Panels | Lenel /AMAG | Lenel and AMAG circuit boards and batteries | Qtrly | |
| 171 | 1 | Large Pilferage cage | Comm/ACS | Door Group | Lenel | Lenel keypad, CAC reader, 4 motion sensors, emergency release button, audio horn, electrical claw lock and indicated light | Qtrly | |
| 171 | 1 | Small Pilferage Cage | Comm/ACS | Door Group | Lenel | CAC Reader, Electrical claw lock, BMS , Emergency release button | Qtrly | |
| 171 | 1 | CCTV | CCTV | PTZ Camera | Pelco | IP PTZ camera | Qtrly | |
| 171 | 1 | Personnel Door 6 | ACS | Door Group | Lenel | CAC reader, Sensor, BMS and electrical striker | Qtrly | |
| 171 | 1 | Personnel Door 6A | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 171 | 1 | Personnel Door 7 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 171 | 1 | Overhead Door 8 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 171 | 1 | Personnel Door 9 | ACS | Door Group | LENEL | BMS and audio siren | Qtrly | |
| 171 | 1 | Overhead Door 10 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 171 | 1 | Overhead Door 11 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 171 | 1 | Overhead Door 12 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 171 | 1 | Personnel Door 13 | ACS | Door Group | LENEL | BMS and audio siren | Qtrly | |
| 171 | 1 | Overhead Door 14 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 171 | 1 | Overhead Door 15 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 171 | 1 | Personnel Door 16 | ACS | Door Group | LENEL | BMS and audio siren | Qtrly | |
| 171 | 1 | Overhead Door 17 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 171 | 1 | Inner overhead Door North | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 171 | 1 | Inner overhead Door South | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 171 | 1 | Overhead Door 18 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 171 | 1 | Personnel Door 19 | ACS | Door Group | LENEL | BMS and audio siren | Qtrly | |
| 171 | 1 | Overhead Door 20 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 171 | 1 | Personnel Door 21 | ACS | Door Group | LENEL | electric striker, BMS and CAC reader | Qtrly | |
| 171 | 1 | Overhead Door 22 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| 171 | 1 | Overhead Door 23 | ACS | Door Group | LENEL | BMS's | Qtrly | |
| BLDG.175 | ||||||||
| 175 | 1 | PTZ Cameras | CCTV | PTZ Cameras | Pelco | Four Pelco ptz cameras on each corner of the building | Qtrly | |
| 175 | 1 | Front Admin Door | ACS | Door Group | Lenel | Mag Lock, CAC reader, BMS and emergency release | Qtrly | |
| 175 | 1 | RT/ SMP PANELS (East Receiving area) | COMM | CONTROL PANELS | Lenel /AMAG | Lenel circuit boards, batteries, and Altronix batteries back-up system | Qtrly | |
| 175 | 1 | Overhead Door 1 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 175 | 1 | Overhead Door 2 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 175 | 1 | Overhead Door 3 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 175 | 1 | Overhead Door 4 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 175 | 1 | Overhead Door 7 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 175 | 1 | Overhead Door 8 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 175 | 1 | Overhead Door 8A | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 175 | 1 | Personnel Door 9 | ACS | Door Group | Lenel | BMS, Mag Lock and audio siren | Qtrly | |
| 175 | 1 | Overhead Door 10 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 175 | 1 | Radiation Cage | ACS | Door Group | Lenel | Lenel keypad, CAC reader, 4 motion sensors, BMS's, emergency release button, electrical claw lock | Qtrly | |
| 175 | 1 | Hazardous Cage | ACS | Door Group | Lenel | Lenel keypad, CAC reader, 4 motion sensors, maglock, BMS's, emergency release button, electrical claw lock | Qtrly | |
| 175 | 1 | IP Camera (Hazardous area) | CCTV | PTZ Camera | Pelco | One IP camera with power supply injector | Qtrly | |
| 175 | 1 | RTV/ SMP PANELS (Hazardous area) | COMM | CONTROL PANELS | Lenel /AMAG | Lenel and AMAG circuit boards, batteries, audio horn and Altronix batteries back-up system | Qtrly | |
| 175 | 1 | Old Inventory Office Door 11 | ACS | Door Group | Lenel | CAC reader, elec. Striker, BMS and sensor. | Qtrly | |
| 175 | 1 | Personnel Door 12 | ACS | Door Group | Lenel | BMS and audio siren | Qtrly | |
| 175 | 1 | Overhead Door 13 | ACS | Door Group | Lenel | BMS"s | Qtrly | |
| 175 | 1 | Overhead Door by room 307 | ACS | Door Group | Lenel | BMS"s | Qtrly | |
| 175 | 1 | Personnel Door (307) | ACS | Door Group | Lenel | CAC reader, indicator light, BMS, Mag Lock, audio horn and emergency release | Qtrly | |
| 175 | 1 | RTV / SMP Panels (room 307) | Comm | Control Panels | Lenel/ AMAG | Lenel / AMAG circuit boards, audio horn batteries, indicator light and 5 motion sensors | Qtrly | |
| 175 | 1 | Overhead Doors | ACS | Door Group | Lenel | Three doors with BMS's | Qtrly | |
| 175 | 1 | Overhead Door (room 311) | ACS | Door Group | Lenel | BMS"s, Lenel Keypads, audio horn and motion sensors (4) | Qtrly | |
| 175 | 1 | Overhead Door (room 312) | ACS | Door Group | Lenel | BMS"s, Lenel Keypads and motion sensors (4) | Qtrly | |
| 175 | 1 | RTV / SMP Panels (room 312) | Comm | Control Panels | Lenel/ AMAG | Lenel and AMAG circuit boards, batteries, and Altronix batteries back-up system | Qtrly | |
| 175 | 1 | Overhead Door 14 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 175 | 1 | Overhead Door 15 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 175 | 1 | Personnel Door 16 | ACS | Door Group | Lenel | BMS and audio siren | Qtrly | |
| 175 | 1 | Overhead Door 17 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 175 | 1 | Personnel Door 18 | ACS | Door Group | Lenel | CAC reader, BMS, ELEC. STRIKER | Qtrly | |
| 175 | 1 | Overhead Door 19 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 175 | 1 | Key box 16 slots | ACS | Global Facilities Management | ||||
| System App (GFMS) | Key System, Inc | Outside of front door is the key box | Qtrly | |||||
| 175 | 1 | Ped. Gate | ACS | Door Group | Lenel | Two CAC readers and an mag lock | Qtrly | |
| BLDG.176 | ||||||||
| 176 | 1 | Front Door | ACS | Door GROUP | Lenel | CAC Reader, Two mag locks, BMS's, audio horn and Emergency release button | Qtrly | |
| 176 | 1 | RTV/ SMP PANELS (IT's switch room) | Comm | Control Panels | Lenel | Lenel circuit boards, batteries, and Altronix batteries back-up system | Qtrly | |
| 176 | 1 | IT's switch door | ACS | Door Group | Lenel | CAC Reader, Elec. Striker and BMS. | Qtrly | |
| 176 | 1 | IT's switch door ( 2nd Door) | ACS | Door Group | Lenel | BMS | Qtrly | |
| 176 | 1 | Personnel Door 2 | ACS | Door Group | Lenel | BMS and audio siren | Qtrly | |
| 176 | 1 | Overhead Door 3 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 176 | 1 | Overhead Door 4 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 176 | 1 | Overhead Door 5 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 176 | 1 | Overhead Door 6 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 176 | 1 | Overhead Door 7 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 176 | 1 | Overhead Door 8 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 176 | 1 | Overhead Door 9 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 176 | 1 | Personnel Door 10 | ACS | Door Group | Lenel | BMS and audio siren | Qtrly | |
| 176 | 1 | Overhead Door 11 | ACS | Door Group | Lenel | BMS's | Qtrly | |
| 176 | 1 | Personnel Door 12 | ACS | Door Group | Lenel | BMS and audio siren | Qtrly | |
| 176 | 1 | Personnel Door 13 | ACS | Door Group | Lenel | BMS and audio siren | Qtrly | |
| Qtrly | ||||||||
| Mayport BLDG.191, 2023 and 2028 | ||||||||
| 191 | 1 | Fixed cameras | CCTV | Cameras | Samsung | Four fixed cameras… installed at East and North vehicle gates, one inside the PPV room and one at receiving area. | Qtrly | |
| 191 | 1 | Main office door | ACS | Door Group | Lenel | CAC reader, BMS,and elec. Striker | Qtrly | |
| 191 | 1 | A phones | COMM | Door GROUP | A PHONE | Six A phone/w cameras…one at East gate, two in main office, one on rear door of main office, one at receiving and one in MPC area. | Qtrly | |
| 191 | 1 | Key box | ACS | Door GROUP | Key System, Inc- GFMS | 16 slots Key box on the outside West wall of Bldg.2028 | Qtrly | |
| 191 | 1 | Side Admin Door | ACS | Door GROUP | Lenel | BMS | Qtrly | |
| 191 | 1 | Rear Admin Door | ACS | Door GROUP | Lenel | Elec. Door striker and BMS | Qtrly | |
| 191 | 1 | Receiving Personnel Door | ACS | Door GROUP | Lenel | CAC reader, Elec. Striker, emergency release and BMS. | Qtrly | |
| 191 | 1 | Receiving Overhead door | ACS | Door GROUP | Lenel | BMS"s | ||
| 191 | 1 | CASREP ROOM | ACS | Door GROUP | Lenel/Radionics/Bosch | Lenel keypad, Bosch keypad, CAC reader, BMS, Motion Sensors, audio horn , elec. striker and emergency release | Qtrly | |
| 191 | 1 | Overhead Door | ACS | Door GROUP | Lenel/Radionics/Bosch | BMS | ||
| 191 | 1 | PPV CAGE Door | ACS | Door GROUP | Lenel/Radionics/Bosch | Lenel keypad, CAC reader, BMS, Motion Sensors, mag lock and emergency release | Qtrly | |
| 191 | 1 | RTV/SMP PANEL | COMM | CONTROL PANELS | Lenel/Radionics/Bosch | Lenel / Radionics and Bosch circuit boards, batteries, and Altronix batteries back-up system | Qtrly | |
| 191 | 1 | Personnel door 3 | ACS | Door GROUP | Lenel | BMS | Qtrly | |
| 191 | 1 | Overhead door 4 | ACS | Door GROUP | Lenel | BMS"s | Qtrly | |
| 191 | 1 | Overhead Door 5 | ACS | Door GROUP | Lenel | BMS"s | Qtrly | |
| 191 | 1 | Personnel door 6 | ACS | Door GROUP | Lenel | BMS | Qtrly | |
| 191 | 1 | Overhead door 7 | ACS | Door GROUP | Lenel | BMS"s | Qtrly | |
| 191 | 1 | Overhead door 8 | ACS | Door GROUP | Lenel | BMS"s | Qtrly | |
| 191 | 1 | Personnel door 9 | ACS | Door GROUP | Lenel | BMS"s | Qtrly | |
| 191 | 1 | Overhead door 10 | ACS | Door GROUP | Lenel | BMS"s | Qtrly | |
| 191 | 1 | Overhead Door 11 | ACS | Door GROUP | Lenel | BMS"s | ||
| 191 | 1 | Overhead Door 12 (hazmat) | ACS | Door GROUP | Lenel | BMS"s | Qtrly | |
| 191 | 1 | Overhead Door 13 | ACS | Door GROUP | Lenel | BMS"s | Qtrly | |
| 191 | 1 | Sliding gate (SERMART) | ACS | Door GROUP | Lenel | BMS"s | Qtrly | |
| 191 | 1 | Emergency exit door (MPC) | ACS | Door GROUP | Lenel | BMS | Qtrly | |
| 191 | 1 | 1/2 Overhead Door (MPC) | ACS | Door GROUP | Lenel | BMS"s | Qtrly | |
| 191 | 1 | Overhead Door 14 | ACS | Door GROUP | Lenel | BMS"s | Qtrly | |
| BLDG.2023 | ||||||||
| 2023 | 1 | Personnel Door 1 | ACS | Door GROUP | Lenel | BMS | Qtrly | |
| 2023 | 1 | Overhead Door 2 | ACS | Door GROUP | Lenel | BMS"s | Qtrly | |
| 2023 | 1 | Personnel Door 3 | ACS | Door GROUP | Lenel | BMS | Qtrly | |
| 2023 | 1 | Overhead Door 4 | ACS | Door GROUP | Lenel | BMS"s | Qtrly | |
| 2023 | 1 | RTV/SMP PANEL | COMM | CONTROL PANELS | Lenel | Lenel circuit boards and batteries. | Qtrly | |
| Qtrly | ||||||||
| BLDG.2028 | Qtrly | |||||||
| 2028 | 1 | RTV/SMP PANEL | COMM | CONTROL PANELS | Lenel | Lenel circuit boards and batteries. | Qtrly | |
| 2028 | 1 | PUSH BUTTON TO OPEN GATE | ACS | Door GROUP | Lenel | Inside bldg. 2028 and 191 are four stations to open East vehicle gate | Qtrly | |
| 2028 | 1 | pedestrian gate | A-phone | Camera | A-Phone | Two CAC readers, maglock and BMS | Qtrly | |
| 2028 | 1 | Office | ACS | Door GROUP | Lenel | BMS and motion Sensor. | Qtrly |