SOW Attachment 5_Bullet Resisting Panel Feet Examples.pdf

PDF 547 KB Posted

Attached to
Joint Recruiting Facilities Bullet-Resisting Panels for CONUS & OCONUS Locations
Solicitation number
W9128F25QA066
Issued by

About this file

Attachment 5 provides detailed specifications for bullet-resistant panel feet, focusing on a triangle-shaped foot design for freestanding panels. The document specifies that the feet must be flexible for various installation configurations, including placement against desks, walls, or in open areas. Each panel foot can be individually inserted, with a preferred triangle foot option that allows for stability and adaptability.

Key technical details include a 2.5-inch thick panel with a half-inch variance, panel lengths ranging from 28" to 36", and a standard height of 48". The feet are designed to have a mounting width that varies based on panel length, with potential placement on one or both sides of the panel. The feet must match the trim color specified, and additional feet may be required depending on the specific installation configuration. The document emphasizes that the example panel is for illustrative purposes, and actual production should follow the Statement of Work (SOW) requirements for measurements, colors, and other specifications.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Bullet-Resistant Panel Feet Example

Foot: Triangle Option – Aerial

View

Foot: Triangle Option – Side View

Attachment 5

The freestanding panels (CLIN 0001 thru 0008) MUST have the flexibility to be used up against or adjacent to desks, walls or in open areas. Each foot to be individually inserted / applied to the panel as necessary.

If a triangle option is necessary for stability, the easiest attachment methods shall be presented to the Government for review, selection and approval.

Other options may be presented for approval.

Left or Right Triangle Option –

Front View Other options may be presented for approval.

Color of feet to match trim color specified.

Color of feet to match trim color specified.12”

4”

1/4” Max 12”

Preferred Option:

48” H

Attachment 5

Other options may be presented for approval.

The portions of the feet shown overlapping the blue panels should be hidden as much as possible once assembled. Or if installed against a wall and the foot is removed from one side, that side shall have a finished look (without the foot installed).

Panel Unit End View: Option B (triangle feet)

Preferred option is also shown at the bottom of Slide #1 above.

Front View Including a Return (with individual panel sections)

28” L 36” L 36” L 48” H

100” L

Attachment 5

2.5” Thick Panels (1/2 inch variance)

R e t u r n

P a n e l

Preferred Foot Option (Triangle

Foot): Front View

100” L

Attachment 5

28” L 36” L 36” L

36” L

Preferred Foot Option: Aerial View 12” H

Additional feet may be required other than those shown and/or in a different configuration. Feet mounting width varies with the length of the panel sections.

Attachment 5

Feet may be required on both sides of the panel to be adequately supported on its own. Or only on one side if installed against a wall (one side would be removed at installation and left at the facility for future use). Or in a different configuration.

5100” L

Attachment 5

Additional feet may be required other than those shown and/or in a different configuration.

Panel shown was for example purposes only.

The SOW requirements for measurements, colors, etc. are to be followed for panel production.

Bullet-Resistant Panel Feet Example
Bullet-Resistant Panel Feet Example
Bullet-Resistant Panel Feet Example
Bullet-Resistant Panel Feet Example
Bullet-Resistant Panel Feet Example
Bullet-Resistant Panel Feet Example

File details come from the government source that posted it. Updated .