SOW Attachment (2) Existing Conditions and Pictures.pdf
PDF 5 MB Posted
- Solicitation number
- N64498-25-R-4014
About this file
This attachment contains module configuration data, system diagrams, floor plans, and photographs documenting the existing fire alarm control panel (FACP) and related systems in Building 29. The first section details the configuration of 58 addressable modules including duct detectors, monitors, pull stations, smoke detectors, and control relays for equipment shutdown and elevator recall, using a Notifier NFS2-640 panel.
The document includes detailed floor plans showing the layout of fire alarm components across first floor, mezzanine, and second floor levels, along with riser diagrams and control system schematics. A series of 15 photographs document the existing conditions, including the fire pump room, main risers, flow switches, existing FACP panel location, and proposed new FACP panel locations in the northeast stairway. Key components shown include duct detectors for various air handling units, sprinkler monitoring devices, pull stations on different floors, smoke detectors in critical areas like labs and elevator lobbies, and control relays for equipment shutdown.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Device
ADDR
INSTL
Module Type
Type Code Label
FlashScan Type
Custom Label
Extended Label
Walk Test Part.
SW
INH
Silenceable
CBE
CBE
CBE
CBE
CBE
Waterflow Delay
1 False False False
2 True Monitor Latch Superv MINI/DUAL MONITOR DUCT DETECTOR AHU-3 False False No Z20 0
3 True Monitor Latch Superv MINI/DUAL MONITOR DUCT DETECTOR AHU-2,4,5 False False No Z20 0
4 True Monitor Latch Superv MINI/DUAL MONITOR DUCT DETECTOR HAC-1,2,3 False False No Z20 0
5 True Monitor Latch Superv MINI/DUAL MONITOR DUCT DETECTOR HAC-4 False False No Z20 0
6 True Monitor Tamper MINI/DUAL MONITOR SPRINKLER VALVE SWITCHES False False No Z31 0
7 True Monitor Non Fire MINI/DUAL MONITOR SPARE False False No Z80 0
8 True Monitor Non Fire MINI/DUAL MONITOR SPARE False False No Z80 0
9 True Monitor Non Fire MINI/DUAL MONITOR SPARE False False No Z80 0
10 True Monitor Non Fire MINI/DUAL MONITOR SPARE False False No Z80 0
11 True Monitor Pull Station ZONE MONITOR 1ST FLOOR EAST False False No Z10 0
12 True Monitor Pull Station ZONE MONITOR MEZZ LEVEL EAST False False No Z11 0
13 True Monitor Pull Station ZONE MONITOR MEZZ LEVEL WEST False False No Z11 0
14 True Monitor Pull Station ZONE MONITOR 2ND FLOOR EAST False False No Z12 0
15 True Monitor Pull Station ZONE MONITOR 2ND FLOOR WEST False False No Z12 0
16 True Monitor Smoke Conven ZONE MONITOR ELEVATOR LOBBY SMOKES False False No Z25 0
17 True Monitor Pull Station ZONE MONITOR WAREHOUSE False False No Z10 0
18 True Monitor Smoke Conven ZONE MONITOR FACP ROOM & HOLDING ROOM False False No Z10 0
19 True Monitor Smoke Conven ZONE MONITOR LAB AREA B False False No Z10 0
20 True Monitor Smoke Conven ZONE MONITOR LAB AREA A False False No Z10 0
21 True Monitor Non Fire ZONE MONITOR SPARE False False No Z80 0
22 True Monitor Non Fire ZONE MONITOR SPARE False False No Z80 0
23 True Control Relay RELAY AHU-1 SHUTDOWN False False No Z89 Z0 0
24 True Control Relay RELAY AHU-2 SHUTDOWN False False No Z89 Z0 0
25 True Control Relay RELAY AHU-3 SHUTDOWN False False No Z89 Z0 0
26 True Control Relay RELAY AHU-4 SHUTDOWN False False No Z89 Z0 0
27 True Control Relay RELAY AHU-5 SHUTDOWN False False No Z89 Z0 0
28 True Control Relay RELAY AHU-6 SHUTDOWN False False No Z89 Z0 0
29 True Control Relay RELAY AH-2 SHUTDOWN False False No Z89 Z0 0
30 True Control Relay RELAY AH-3 SHUTDOWN False False No Z89 Z0 0
31 True Control Relay RELAY AH-4 SHUTDOWN False False No Z89 Z0 0
32 True Control Relay RELAY AH-5 SHUTDOWN False False No Z89 Z0 0
33 True Control Relay RELAY SPARE False False No Z89 Z0 0
34 True Control Relay RELAY ELEVATOR RECALL False False No Z89 Z25 0
35 True Control Relay RELAY LAB AREA FAN SHUTDOWN False False No Z89 Z0 0
36 False False False
37 False False False
38 False False False
39 False False False
40 True Monitor Waterflow MONITOR UTIITY ROOM 1M040 False False No Z90 Z6 0
41 True Monitor Waterflow MONITOR 1 SERVER RM 1M041 False False No Z90 Z6 0
42 True Monitor Waterflow MONITOR 2 SERVER RM 1M042 False False No Z90 Z6 0
43 True Monitor Monitor MONITOR FIRE PUMP RUN False False No Z80 0
44 True Monitor Latch Superv MONITOR FIRE PUMP A/C FAIL False False No Z6 0
45 True Monitor Latch Superv MONITOR FIRE PUMP REVERSAL False False No Z6 0
46 True Monitor Tamper MONITOR FIRE PUMP RISER TAMP False False No Z6 0
47 True Monitor Waterflow MONITOR FIRE PUMP RISER FLOW False False No Z6 Z90 0
48 True Monitor Tamper MONITOR FIRE PUMP INLET OUTPUT False False No Z6 0
49 True Monitor Tamper MONITOR FIRE PUMP BYPASS False False No Z6 0
50 True Monitor Tamper MONITOR MAIN BLDG False False No Z6 0
51 False False False
52 False False False
53 False False False
54 False False False
55 False False False
56 False False False
57 False False False
58 False False False
Notifier VeriFire Tools 11.50 build 42 / Software Version Numbers for Node 0 / Date: 10/25/2021,Time: 11:03 AM
Project Details: (Name: Bldg 29, Ver: 1.0)
NodeDetails: (Address: 0, Type: NFS2-640, DBVer: 21.0, TimeStamp: 5/19/2021 6:34:00 PM, Label: PNBC BUILDING 29) neal.j.moran Text Box SOW Attachment 2 Fire Alarm Control Panel (FACP) Module Pts.
BLDG 29 Fire Alarm & Mass Notification System (FA&MNS) Repair Sheet 1 of 12 neal.j.moran Text Box SOW Attachment 2 Fire Alarm Control Panel (FACP) Existing Controls Diagram
Sheet 2 of 12
SOW Attachment 2 Fire Alarm Control Panel (FACP) Floor Plan Layout
Sheet 1 of 12
SOW Attachment 2 Fire Alarm Control Panel (FACP) Floor Plan Layout
Sheet 4 of 12
SOW Attachment 2 Fire Alarm Control Panel (FACP) Floor Plan Layout
Sheet 5 of 12
Line neal.j.moran Typewritten Text N neal.j.moran Callout Main line from Pump room. Tamper switch.
neal.j.moran Rectangle neal.j.moran Callout Building 29 Pump Room, Located Outside.
neal.j.moran Callout Existing FACP neal.j.moran Callout New Proposed FACP Location neal.j.moran Callout Flow Riser Locations -- Tamper switches / Flow switches neal.j.moran Callout Flow switch to machine shop/elevator rooms neal.j.moran Callout Elevator neal.j.moran Text Box SOW Attachment 2 Fire Alarm Control Panel (FACP) 1st Floor Plan Layout BLDG 29 Fire Alarm & Mass Notification System (FA&MNS) Repair Sheet 6 of 12 neal.j.moran Callout Existing Chemical Dry Suppression System to be Monitored by FACP
PROJECT NORTH
D
RA
W N
B Y:
N
AV
AL
S
U
RF
AC
E
W
AR
FA
RE
C
EN
TE
R
PH
IL
AD
EL
PH
IA
, P A
D
ES
IG
N
ED
B
Y:
DW
G N
AM
E:
SH
EE
T
SI
ZE
4.
.2
4.
.2
CO
DE
SA
VE
D
AT
E:
SC
AL
E:
PL
O
T
DA
TE
N O
TE
S:
SHEET of
N
FA
_2 9_
2_
FP
.d w g
29-2
BU
IL
D
IN
G
FL
O O
R
D
RA
FT
L
AY
O
U T
XX
XX
XX
X
1 1
AN
SI
e xp an d
B (1
1.
x
7.
In ch es
1"
1.
neal.j.moran Text Box SOW Attachment 2 Fire Alarm Control Panel (FACP) 2nd Floor Plan Layout
Sheet 7 of 12
SOW Attachment 2 Fire Alarm Control Panel (FACP) Mezz Floor Plan Layout
Sheet 8 of 12
SOW ATTACHMENT 3
PHOTOGRAPHS – FA&MNS INFORMATION
BUILDING 29 – FA&MNS PROJECT
Sheet 1 of 4.
BUILDING 29 – FIRE ALARM AND MASS NOTIFICATION PROJECT - PHOTOGRAPHS
PHOTO 1 – BLDG 29 Fire Pump Room Building PHOTO 2 – BLDG 29 Fire Pump Room
PHOTO 3 – BLDG 29 Fire Pump Room PHOTO 4 – BLDG 29 Fire Pump Room
Text Box SOW Attachment 2 Fire Alarm Control Panel (FACP) Photographs
Sheet 9 of 12
BUILDING 29 – FA&MNS PROJECT
Sheet 2 of 4.
PHOTO 5 – BLDG 29 Fire Pump Room PHOTO 6 – BLDG 29 Fire Pump Room
PHOTO 7 – BLDG 29 Main Riser Into Building 29. PHOTO 8 – BLDG 29 Main Riser For Each Floor
Text Box SOW Attachment 2 Fire Alarm Control Panel (FACP) Photographs
Sheet 10 of 12
Sheet 3 of 4.
PHOTO 9 – BLDG 29 Main Riser For Each Floor PHOTO 10 – BLDG 29 Main Riser For Each Floor
Not Used
PHOTO 11 – BLDG 29 Flow switch for Machine Shop and Elevator Room neal.j.moran Text Box SOW Attachment 2 Fire Alarm Control Panel (FACP) Photographs
Sheet 11 of 12
Sheet 4 of 4.
PHOTO 12 – BLDG 29 Existing FACP Panel PHOTO 13 – BLDG 29 Existing FACP Panel
PHOTO 14 – BLDG 29 Proposed New FACP Panel Location – NE Stairway PHOTO 15 – BLDG 29 Proposed Alternate New FACP Panel Location – NE Stairway
SOW Attachment 2 Fire Alarm Control Panel (FACP) Photographs
Sheet 12 of 12
| SOW Attachment (2) Existing Conditions and Pictures |
| Bldg 29 Module Points list |
| PH0000029_E01FP_R01_10755 |
| PH0000029_E01FP_R01_10757 |
| PH0000029_E01FP_R01_10758 |
| PH0000029_EM1FP_R01_10759 |
| Bldg 29 -- 1st Floor -- Floorplan |
| Bldg 29 -- 2nd Floor -- Floorplan |
| Bldg 29 -- Mezz Floor -- Floorplan |
| SOW Attachment (3) Photographs |
File details come from the government source that posted it. Updated .