SolicitationAttachment3WaterValves_1232SA26Q0991.pdf
PDF 23 KB Posted
- Solicitation number
- 1232SA26Q0991
About this file
This is a technical specification document for a water distribution system infrastructure project at a compound facility. The document provides detailed inventory and planning information for a multi-vault water line system with specifications for piping materials, sizes, valve placements, and line lengths.
The system comprises five primary vaults (A through E) and seven secondary vaults distributed throughout the compound. Vault A (Northeast Corner of Woodshed) serves as the main distribution point, receiving a 1¼" PVC line and distributing water to an office building (ARS-25) and downstream vaults. The water distribution network includes multiple line sizes: 1" PVC, 1¼" PVC, 2" PVC, and 2" poly lines, with a total existing line length of 937 feet inside the compound. The document specifies current valve inventory within each vault and identifies additional valves needed for vaults 1 through 7, including gate valves in sizes 1", 1¼", and ¾". Two configuration options are presented: one maintaining current mixed-size piping and another standardizing to 1" water lines for vaults A-E. The 1" standardized option requires nine 1" gate valves total for the five primary vaults. Line segments include connections from Vault A to ARS-25 (167 feet), Vault B to Vault C and East Quonset Hydrant (45-123 feet), and Vault B to south compound (112 feet), with specific transitions between pipe materials noted at various points throughout the system.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Vault A (Northeast Corner of Woodshed) B (3 Hole in front of Quonset) 2" line coming in C (North of Quonset) 1" pvc line D (South compound) 1 1/4" pvc E (can next to ARS-10) 5 ball valves 1 1/4" hole 1 (North) 1" gate valve 2- 1" gate valves 3- 1 1/4" gate valves, 1- 1" gate valve 1" pvc line to 2" pvc line that enters building Line exiting vault is 1 1/4" pvc hole 2 (Center) 1" gate valve line coming in is 1 1/4" pvc line, exits vault with 2" poly line Goes to 2" poly pipe to the south hole 3 (South) 2" gate valve
Total line length (ft) from Vault A to ARS-25 Line length (ft) from Vault A to Vault B (3-hole)
Line length from East shop to West shop (ft)
Line length from Vault B (3-hole) to Vault C and Vault C to East Quonset Hydrant (ft)
Line length from Vault B (3-hole) to Vault E
(ARS-10)
167 75 65 40 34 175 48 77
45 123 117
Line length (ft) from Vault B (3-hole) to Vault D (south compound)
Line length from Vault D (south compound) to southwest quonset hydrant (ft) Total line length of various sizes (ft)
112 77 937 7 (leg that goes back East to the vault)
Vault 1-D (south compound) Vault 2(curve in road) Vault 3 (East of gatehouse) Vault 4 (North of transit line pump) Vault 5 (Next to Model C/ ARS-9) Vault 6 (ARS-6) Vault 7 (East of spillway channel) 1- 1" gate valve 2- 1 1/4" gate valves 3- 1 1/4" gate valves 1- 1 1/4" gate valve Nothing we are going to wait for Dam rehab 1-1 1/4" gate valve 2- 1 1/4" gate valves 1- 1 1/4" gate valve 1- 3/4" gate valve
10- 1 1/4" gate valves total from Vault 1 to vault 7 1- 3/4" gate valve total
A (Northeast Corner of Woodshed) B (3 Hole in front of Quonset) C (North of Quonset) D (South compound) E (can next to ARS-10) 3- 1" gate valves 3- 1" gate valves 2- 1" gate valves 1- 1" gate valve No valve needed shutoff inside building
9- 1" gate valves total
Line comes in Vault A at 1 1/4" pvc, turns back West to go to office building (ARS-25) all pvc, exits vault South at 1 1/4" pvc then transitions somewhere after to 2" poly line probably close to Vault A. Tees off in front of machine shop (underground- no vault associated) most likely pvc line to carpenter shop. Line continues South poly line into Hole 1
(North) of the three hole vault. From there line goes to 1 1/4" pvc into Vault D (south compound), then line going back to the Quonset hydrant is 1" pvc. Line exiting South of Vault D (south compound) transitions to 2" poly line through the rest of the lab.
Existing line length (ft) inside the compound
What is currently inside each Vault
Valves needed for vaults 1 through 7
Valves needed if we go with 1" water line for Vaults A-E (inside the compound)