This is a Request for Quote (RFQ) for the procurement of vehicle access control gate systems by the U.S. Bureau of Reclamation's Pacific Northwest Region. The solicitation number is 140R1726Q0027, with a quote due date of August 14, 2026 at 5:00 PM Eastern Time. The solicitation is issued as a Women-Owned Small Business (WOSB) set-aside at 100% for commercial products and services. The Contracting Officer is Donald Richer (donald_richer@ios.doi.gov, 509-633-9515), and the procurement is for delivery by December 31, 2026 to multiple destinations.

The requirement consists of four line items totaling six automated vehicle access control gate systems for critical infrastructure security at two National sites: Hungry Horse Dam (Montana) with two systems, one gate per system, and Grand Coulee Dam (Washington) with two systems, two gates per system. Item 1 specifies one Hungry Horse Hydraulic Vertical Pivot Gate (right hand open, 21 feet length, 8 feet height with amplimesh and barbed wire), and Item 2 specifies one Hungry Horse Drop Arm Beam Barrier Gate System (Delta Scientific DSC7000(H) or equivalent, K12/M50 crash rating). Items 3 and 4 cover Grand Coulee requirements: two hydraulic vertical pivot gates (one right hand, one left hand open, 14 feet length, 8 feet height) and two drop arm beam barrier gate systems. All systems must be new, prefabricated, pre-wired, pre-balanced, and capable of integration with Software House CCure 9000 access control systems. Systems require 3-year warranties, weatherproof construction, extensive accessories (cold weather packages, loop detectors, reversing edges, magnetic locks, photo eyes, siren-operated sensors, electrical box heaters), and detailed documentation including shop drawings, certificates of craftsmanship, installation instructions, wiring diagrams, and maintenance guides. Shipping is FOB destination and must not be quoted separately. Contractors must submit a Pricing Gate Checklist, shop drawings, warranty documentation, and specifications demonstrating compliance with government requirements.

View the file

Other files

File Type Posted
Sol_140R1726Q0027_Amd_0002.pdf PDF
Sol_140R1726Q0027_Amd_0001.pdf PDF
Pricing_Gate_Checklist.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WOMEN-OWNED SMALL

BUSINESS (WOSB)

SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL PRODUCTS AND COMMERCIAL SERVICES

1. REQUISITION NUMBER PAGE 1 OF

2. CONTRACT NUMBER 3.AWARD/EFFECTIVE

DATE

4. ORDER NUMBER 5. SOLICITATION NUMBER 6. SOLICITATION ISSUE

DATE

7. FOR SOLICITATION

INFORMATION CALL:

a. NAME b. TELEPHONE NUMBER (No collect calls)

8. OFFER DUE DATE/

LOCAL TIME

9. ISSUED BY

13b. RATING

14. METHOD OF SOLICITATION

CODE

15. DELIVER TO 16. ADMINISTERED BY CODE

18a. PAYMENT WILL BE MADE BY CODE17a. CONTRACTOR/

OFFEROR

CODE

FACILITY

CODE

CODE

TELEPHONE NUMBER

17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT SUCH ADDRESS IN

OFFER

18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a UNLESS BLOCK

BELOW IS CHECKED

REQUEST

FOR QUOTE

(RFQ)

INVITATION

FOR BID

(IFB)

REQUEST

FOR

PROPOSAL

(RFP)

SEE ADDENDUM

19.

ITEM NO.

20.

SCHEDULE OF SUPPLIES/SERVICES

21.

QUANTITY

22.

UNIT

23.

UNIT PRICE

24.

AMOUNT

(Use Reverse and/or Attach Additional Sheets as Necessary)

25. ACCOUNTING AND APPROPRIATION DATA 26. TOTAL AWARD AMOUNT (For Government Use Only)

28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN 29. AWARD OF CONTRACT: REFERENCE

. YOUR OFFER ON SOLICITATION

(BLOCK 5), INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE

SET FORTH HEREIN, IS ACCEPTED AS TO ITEMS:

30a. SIGNATURE OF OFFEROR/CONTRACTOR

30b. NAME AND TITLE OF SIGNER (Type or print) 30c. DATE SIGNED

31a. UNITED STATES OF AMERICA (SIGNATURE OF CONTRACTING OFFICER)

31b. NAME OF CONTRACTING OFFICER (Type or print) 31c. DATE SIGNED

AUTHORIZED FOR LOCAL REPRODUCTION

PREVIOUS EDITION IS NOT USABLE

STANDARD FORM 1449 (REV. 11/2021)

Prescribed by GSA - FAR (48 CFR) 53.212

10. THIS ACQUISITION IS UNRESTRICTED OR

NORTH AMERICAN

INDUSTRY CLASSIFICATION

STANDARD (NAICS):

SIZE STANDARD:

13a. THIS CONTRACT IS A

RATED ORDER UNDER

THE DEFENSE PRIORITIES

AND ALLOCATIONS

SYSTEM - DPAS (15 CFR 700)

SET ASIDE: % FOR:

11. DELIVERY FOR FREE ON

BOARD (FOB) DESTINATION

UNLESS BLOCK IS MARKED

SEE SCHEDULE

12. DISCOUNT TERMS

ARE ARE NOT ATTACHED

ARE ARE NOT ATTACHED

27a. SOLICITATION INCORPORATES BY REFERENCE (FEDERAL ACQUISITION REGULATION) FAR 52.212-1, 52.212-4.

FAR 52.212-3 AND 52.212-5 ARE ATTACHED.

27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED.

8(A)

ECONOMICALLY

DISADVANTAGED

WOMEN-OWNED SMALL

BUSINESS (EDWOSB)

SERVICE-DISABLED

VETERAN-OWNED

SMALL BUSINESS

(SDVOSB)

HUBZONE SMALL

BUSINESS

SMALL BUSINESS

NOTE: OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, AND 30.

COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH

AND DELIVER ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND

ON ANY ADDITIONAL SHEETS SUBJECT TO THE TERMS AND CONDITIONS

SPECIFIED

DATED.

OFFER

ADDENDA

ADDENDA

140R1726Q0027

Multiple Destinations See Schedule

Bureau of Reclamation Pacific Northwest Region Grand Coulee Acquisition Group Hwy 155, PO Box 620 Grand Coulee WA 99133

08/14/2026 1700 ED

0044041759

Donald Richer 5096339515

R17 100.00

Jeri L. Wahl

331222

1,000

07/31/2026

CONTRACTORS SHALL SUBMIT ALL ITEMS LISTED IN

PROVISION 52.212-1, INSTRUCTIONS TO OFFERORS.

FAILURE TO SUBMIT THESE ITEMS MAY RESULT IN

REJECTION OF QUOTE. SUBMIT PRICING ALONG WITH

OTHER REQUIRED DOCUMENTATION TO DON RICHER AT

DONALD_RICHER@IOS.DOI.GOV.

Continued...

STOCK RECORD (S/R)

STANDARD FORM 1449 (REV. 11/2021) BACK

19.

ITEM NO.

20.

SCHEDULE OF SUPPLIES/SERVICES

21.

QUANTITY

22.

UNIT

23.

UNIT PRICE

24.

AMOUNT

32a. QUANTITY IN COLUMN 21 HAS BEEN

RECEIVED INSPECTED AND CONFORMS TO THE CONTRACT, EXCEPT AS NOTED:

41a. I CERTIFY THIS ACCOUNT IS CORRECT AND PROPER FOR PAYMENT

32b. SIGNATURE OF AUTHORIZED GOVERNMENT

REPRESENTATIVE

32c. DATE

41b. SIGNATURE AND TITLE OF CERTIFYING OFFICER 41c. DATE

42a. RECEIVED BY (Print)

42b. RECEIVED AT (Location)

42c. DATE RECEIVED (MM/DD/YYYY) 42d. TOTAL CONTAINERS

40. PAID BY

32d. PRINTED NAME AND TITLE OF AUTHORIZED GOVERNMENT

REPRESENTATIVE

32e. MAILING ADDRESS OF AUTHORIZED GOVERNMENT REPRESENTATIVE 32f. TELEPHONE NUMBER OF AUTHORIZED GOVERNMENT REPRESENTATIVE

32g. EMAIL OF AUTHORIZED GOVERNMENT REPRESENTATIVE

33. SHIP NUMBER 34. VOUCHER NUMBER 35. AMOUNT VERIFIED

CORRECT FOR

PARTIAL FINAL

37. CHECK NUMBER

38. S/R ACCOUNT NUMBER 39. S/R VOUCHER NUMBER

36. PAYMENT

COMPLETE PARTIAL FINAL

ACCEPTED,

THE LAST DAY TO ASK QUESTIONS IS FRIDAY, AUGUST

7, 2026, 5 PM EASTERN.

NOTE: THESE GATES WILL BE SHIPPED TO TWO

DIFFERENT LOCATIONS, HUNGRY HORSE DAM, MONTANA

AND GRAND COULEE DAM, WASHINGTON.

SHIPPING SHALL BE FOB DESTINATION; SHIPPING

SHALL NOT BE QUOTED SEPARATELY.

Delivery: 12/31/2026

00010 1 EAHungry Horse Hydraulic Vertical Pivot Gate

(Right Hand Open), cold weather package and required additional accessories per attached specification

Product/Service Code: 5660

Product/Service Description: FENCING, FENCES, GATES AND COMPONENTS

Delivery Location Code: 0011285572

Bureau of Reclamation-PN-GCPO

Hungry Horse Field Office

2501 Colorado Blvd

Hungry Horse MT 59919-0131 US

00020 1 EAHungry Horse Drop Arm Beam Barrier Gate System and required additional accessories per

Continued...

CONTINUATION SHEET

REFERENCE NO. OF DOCUMENT BEING CONTINUED PAGES

NAME OF OFFEROR OR CONTRACTOR

SUPPLIES/SERVICES

(B)

UNIT

(D)

UNIT PRICE

(E)

AMOUNT

(F)

OPTIONAL FORM 336 (4-86)

Sponsored by GSA FAR (48 CFR) 53.110

ITEM NO.

(A)

QUANTITY

(C)

NSN 7540-01-152-8067

140R1726Q0027 attached specification

Product/Service Code: 5660

Product/Service Description: FENCING, FENCES, GATES AND COMPONENTS

Delivery Location Code: 0011285572

Bureau of Reclamation-PN-GCPO

Hungry Horse Field Office

2501 Colorado Blvd

Hungry Horse MT 59919-0131 US

00030 2 EAGrand Coulee Dam (Right Hand Open/Left Hand

Open) Hydraulic Vertical Pivot Gate, cold weather package and required additional accessories per attached specification

Product/Service Code: 5660

Product/Service Description: FENCING, FENCES, GATES AND COMPONENTS

Delivery Location Code: 0011285556

Bureau of Reclamation-PN-GCPO

Grand Coulee - Receiving

Hwy 155 - Warehouse B - Door 6

Industrial Area

Grand Coulee WA 99133 US

00040 2 EAGrand Coulee Power Office Drop Arm Beam Barrier

Gate System and additional accessories per attached specification

Product/Service Code: 5660

Product/Service Description: FENCING, FENCES, GATES AND COMPONENTS

Delivery Location Code: 0011285556

Bureau of Reclamation-PN-GCPO

Grand Coulee - Receiving

Hwy 155 - Warehouse B - Door 6

Industrial Area

Grand Coulee WA 99133 US

SPECIFICATION

VEHICLE ACCESS CONTROL GATES

1. INTRODUCTION:

The U.S. Bureau of Reclamation requires a total of six (6) automated vehicle access control gate systems to support the security mission at National Critical Infrastructure sites.

Site 1: Hungry Horse Dam, Flathead County, Montana two (2) systems, one gate per system Site 2: Grand Coulee Dam, Grant County, Washington two (2) systems, two gates per system

Note: Installation will be completed by Reclamation personnel.

2. PURPOSE:

Contractors shall deliver new access control gate systems according to requirements and specifications; used or refurbished structures will not be accepted.

3. REQUIREMENTS (Applicable to All Sites):

a. Products shall be prefabricated, pre-wired, shipped pre-balanced and assembled for ease of installation by Reclamation personnel. Note: Must be capable of integration with Agency’s access card system, Software House CCure 9000.

b. Weatherproof construction for exterior exposure and designed to resist twist and sway.

c. All system components of the gate systems shall meet a warranty period of no less than 3 years.

4. GATE SYSTEMS FOR HUNGRY HORSE AND GRAND COULEE DAM:

ITEM 1 – HYDRAULIC VERTICAL PIVOT GATE.

SITE 1, HUNGRY HORSE REQUIREMENTS:

Provide one hydraulic vertical pivot gate system including One (1) gate panel, with One (1) hydraulic operator, and accessories as required for complete operational installation by Reclamation personnel.

Gate shall be Right Hand Open only: 21'(feet) in length and 7'(feet)+1'(feet) Height, (7' feet) Amplimesh, 1' (feet) barbed wire.

1 EA Tilt-A-Way HYJG-1 Amplimesh (Anti-climb material (wire mesh screen) consisting of welded wire panel mesh fencing with an aperture no larger than 3.5” by 3”) or equivalent

Hydraulic Power Unit: 1 HP TEFC motor, 1800 RPM, 24VDC Hydraulic power unit capable of delivering 4 GPM at 385 PSI, with external adjustment relief valve and 4-way solenoid operated 3-position manual override.

• Hydraulic pump, motor, and reservoir will all be as one unit with fluid thermometer and fluid level sight gauge.

• The hydraulic system will be designed to keep the gate locked in the closed position, keeping any person from lifting the gate open when it is in the closed position.

• Pedestal Frame: Welded construction with removable outer skin of cross break corrosion resistant painted gray .063 aluminum plate panels.

• Inspection Door Hardware: Stainless steel continuous hinges and heavy-duty lockable pull-down catches to hold inspection door shut.

• 115 Volt AC 24 Volt DC battery backup [24 Volt DC motor and control board] [110 Volt AC for battery charger and optional accessories]. The total gate system requires 20-amp service, with no more than 3% drop in voltage, while gate is in operation.

Hydraulic System: 3000-psi hydraulic cylinder.

• Cylinder: 2-1/2" by 38" stroke hydraulic cylinder with 1-3/8" diameter rod, limit switches and cushioned slow down on each end of travel, and adjustable stops with lock down in any position.

• Hydraulic Fluid: Manufacturer's standard, factory checked, filled, and tested.

• Balance System: System designed to allow barrier to be hand raised and to be hand lowered with 12 to 15 pounds of pressure.

• Safety Control Switch: Provide built-in safety control switch capable of stopping barrier in any position should balance system fail.

• Testing: Factory test and adjust balance system to ensure gate may be manually raised and lowered with specified pressure.

Electrical System: Oversized rain tight enclosure housing electrical components except limit switches, safety switches, and motor.

• Wire: Oil and gasoline resistant.

• Overload Protection: Overload protection relay to protect motor.

• Reversing Controller: Provide as required to operate motor and solenoid valves.

• Overrun Delay Timers: Capable of shutting down system in case motor runs longer than expected.

• Limit Switches: Adjustable snap action style limit switches capable of stopping barrier at each end of travel.

Logic Board: Programmable logic board with manufacturer's full range of available functions to include but not limited to:

• Programmable auto-close timer.

o Adjustable duration.

o Auto-reset on active command

• Entrapment and safety sensor.

o Non-contact inputs for photo eye.

o Contact edge input to halt or revers operation on physical contact.

o Closing reversal to reverse the operation when a safety circuit trips.

o Timer hold to stop auto close timer while a safety loop or photo eye detects an obstacle.

• Cycle and access controls.

o Access control system terminals to interface with security systems card readers, and loop detectors.

o Emergency override sensor input for acoustic siren operated sensor.

• Auxiliary and hardware failsafe.

o Overrun delay failsafe input to prevent the motor from overrunning after operation.

o Magnetic lock power to secure the gate in the closed position.

o Status indicator output to power operation indicator lights.

NOTE: Must be compatible with Software House CCure 9000.

Foundation and Footing:

• Concrete Footing: Will be provided and constructed by Reclamation.

• Bolts: NOTE: Vendor shall provide drawings or templates for installation of anchor bolts in support slab.

Additional Accessories Required:

• Cold Weather Package For temperature drops to lower than 35° F.) (1 each gate: total 1)

• Loop Detectors: Provide detector system (exit loop) To allow free exit/safety, or close gate operation;

system to be factory wired inside electrical box and tested. (1 each gate: total 1)

• Reversing Edge: Provide manufactures standard reversing edge system. (1 each gate: total 1)

• Locks: magnetic lock secures gate in closed position. (1 each gate: total 1)

• Photo Eye: Used as a form of safety. (1 each gate: total 1)

• S.O.S.: Siren Operated acoustic Sensor for Emergency Vehicle Override. (Emergency access system). (1 each gate:

total 1)

• Heater-Electrical Box: Provide heater, including full box insulation to protect system for conditions to minus 70° F. (1 each gate: total 1)

Barrier System (Gates): Design to resist twist and to resist sway.

• Type: Aluminum barrier (up to 25-foot-wide opening per gate leaf), nominal 3.125" by 2.875" diamond

6063-T5 alloy aluminum screen fabric welded both sides completely, with sway bracing. Leading member of an aluminum barrier 4" schedule 40 round tube, sway braces- 1 ¼ x 1 ¼ x 1/8 square tube uprights- 2 x 2 x .188 square tube. Sway braces bolted to barrier. Barriers with sway braces are designed to withstand 100 MPH wind load, or optional 150 MHP sway bracing.

• Type: Custom barrier with sway bracing.

• Provide stanchion to contain free end for severe crash applications.

Required Accessories:

• Child Guards: Provide child and small animal guard on secured side of operator.

Finish: Factory prime with Direct to Medal (DTM) epoxy and paint with acrylic urethane to resist corrosion.

Manufactures Standard Gray Color #808080 or equivalent.

ITEM 2 – DROP ARM BEAM BARRIER SYSTEM.

SITE 1, HUNGRY HORSE REQUIREMENTS:

Provide Crash Certified Drop Arm Beam Barrier System with a minimum K12/M50 rating. The system consists of a crash beam, bearing assembly, hinge end support buttress and the hydraulic actuator, power unit, locking bolt with padlock provision, mounting hardware and other options as described below.

1 EA, Delta Scientific DSC7000(H) or equivalent

• Barrier Construction: Barrier shall be a structural assembly containing a crash beam hinged at one end -lockable at the other, which can be raised and lowered hydraulically. When in the down locked position, the beam shall present a formidable obstacle to vehicles moving in either direction.

• Barrier Height: Height of the Barrier shall nominally be 33 inches (0,93 M) as measured from the roadway surface to the centerline of the crash beam.

• Barrier Clear Opening: The standard clear opening shall be 264 inches (22ft) as measured inside-to- inside of the hinge and locking buttress.

• Actuation: The Drop Arm Barricade shall be raised and lowered by means of a hydraulic cylinder driven by a

Hydraulic Power Unit located within the cabinet at the hinge end Buttress.

• Control: The Barricade shall be controlled from a key lockable up/down push button control station mounted on the Barrier (local control) and remotely using the CCURE9000 access control system.

Operator Unit Specifications:

Hydraulic Power Motor: Unit shall consist of an electrically driven hydraulic pump, which shall pressurize a high-pressure manifold connected to a hydraulic accumulator. Electrically actuated valves shall be installed on the manifold to allow oil to be directed to the hydraulic cylinders to raise and lower the drop arm.

• Main Power. The electric motor driving the hydraulic pump shall be fed from (230/3/60). Motor shall be sufficiently sized for the expected number of Barricade operations.

• Manual Operation. A hand pump shall be furnished to allow the Barricades to be raised manually in the event of a power interruption.

• Construction. The hydraulic power unit and accessories shall be mounted and wired and mounted within the hinge end enclosure.

• Manual Locking Pin. The Barrier beam shall be provided with a locking pin with padlock locking point to secure the Barrier in the guard position. Locking pin must be able to accommodate a padlock with a shackle 7/16 inch (11MM).

Control and Logic Circuits:

• Weather Resistant HPU Enclosure. A lockable weather resistant enclosure shall be provided for the HPU. The design shall provide easy access to the HPU for maintenance and emergency operation of the hydraulic system.

• Concrete Footing: will be provided and constructed by Reclamation.

• Bolts: NOTE: Vendor shall provide drawings or templates for installation of anchor bolts in support slab.

Required Accessories:

• Barrier system heater. (Total 1)

• Power unit mounted electrical disconnect. (Total 1)

• Oil reservoir heater; Needs to be sized for the correct hydraulic pumping unit (HPU). (Total 1)

• Three (3) flashing lights mounted to barrier for safety and visibility. (1 Set)

• Two (2) loop detector kits. (Total 2)

Finish and quality assurance:

• Exposed barrier surfaces shall be painted with gloss white, two-part epoxy high weather resistant paint.

The drop arm beam shall be White and fitted with Red reflective tape across its front and back.

• Identification: A nameplate with manufacturer's name, model number, serial number and year built shall be located at the hinged end structure.

• Workmanship: The Barrier shall have a neat and workmanlike appearance.

• Finish: Coatings shall be checked against ordering information and shall be workmanlike in appearance.

Inspection:

Gate systems will be inspected upon delivery, including structural, interior, exterior and electrical components per specifications. Contractor will be responsible for any defects, discrepancies or damage discovered as a result of negligence in fulfilling contracted work, and any return shipping/transportation expense deemed necessary.

Assembly and Installation:

• Placement, set up, installation and final connection tasks to put gate systems in full operation will be completed by Reclamation staff and will not be required by the contractor.

• Manufacturer installation instructions and electrical diagrams shall be provided.

Other Requirements for Drop Arm Barrier:

• Key lockable up/down push button station. (1 each gate: total 1)

• Barrier system heater. (1 each gate: total 1)

• Emergency manual operating system, Hand pump. (1 each gate: total 1)

• Power unit mounted electrical disconnect. (1 each gate: total 1)

• Oil reservoir heater, Delta unit, 500W. (1 each gate: total 1)

• Loop Detector kit. (2 each gate: 2 total)

ITEM 3– HYDRAULIC VERTICAL PIVOT GATES, 2 gates (Right hand & Left hand).

SITE 2, GRAND COULEE REQUIREMENTS:

Provide two (2) hydraulic vertical pivot gates including One (1) gate panel, with One (1) hydraulic operator each gate, and accessories as required for complete operational installation by Reclamation personnel.

Note: Must be Capable of integration with Software House CCURE 9000 access control system.

Gates shall be: One Right Hand Open & One Left Hand Open; 14'(feet) in length and 7'(feet)+1'(feet) Height, (7' feet) Amplimesh, 1' (feet) barbed wire.

1 EA for right hand & left hand, Tilt-A-Way HYJG-1 Amplimesh (Anti-climb material (wire mesh screen) consisting of welded wire panel mesh fencing with an aperture no larger than 3.5” by 3”) or equivalent

Hydraulic Power Unit: 1 HP TEFC motor, 1725 RPM, 208-230 Volt Three-Phase Hydraulic power unit capable of delivering 4 GPM at 385 PSI, with external adjustment relief valve and 4-way solenoid operated 3-position manual override valve.

• Hydraulic pump, motor, and reservoir will all be as one unit with fluid thermometer and fluid level sight gauge.

• The hydraulic system will be designed to keep the gate locked in the closed position, keeping any person from lifting the gate open when it is in the closed position.

• Pedestal Frame: Welded construction with removable outer skin of cross break corrosion resistant painted gray .063 aluminum plate panels.

• Inspection Door Hardware: Stainless steel continuous hinges and heavy-duty lockable pull-down catches to hold inspection door shut.

• Power: 208-230 Volt Three-Phase, 4-Wire.

Hydraulic System: 3000-psi hydraulic cylinder.

• Cylinder: 2-1/2" by 38" stroke hydraulic cylinder with 1-3/8" diameter rod, limit switches and cushioned slow down on each end of travel, and adjustable stops with lock down in any position.

• Hydraulic Fluid: Manufacturer's standard, factory checked, filled, and tested.

Balance System: System designed to allow barrier to be hand raised and to be hand lowered with 12 to 15 pounds of pressure

• Safety Control Switch: Provide built-in safety control switch capable of stopping barrier in any position should balance system fail.

• Testing: Factory test and adjust balance system to ensure gate may be manually raised and lowered with specified pressure.

Electrical System: Oversized rain tight enclosure housing electrical components except limit switches, safety switches, and motor.

• Wire: Oil and gasoline resistant.

• Overload Protection: Overload protection relay to protect motor.

• Reversing Controller: Provide as required to operate motor and solenoid valves.

• Overrun Delay Timers: C apable of shutting down system in case motor runs longer than 30 seconds.

• Limit Switches: Adjustable snap action style limit switches capable of stopping barrier at each end of travel.

Logic Board: Programmable logic board with manufacturer's full range of available functions to include but not limited to:

• Programmable auto-close timer.

o Adjustable duration.

o Auto-reset on active command

• Entrapment and safety sensor.

o Non-contact inputs for photo eye.

o Contact edge input to halt or revers operation on physical contact.

o Closing reversal to reverse the operation when a safety circuit trips.

o Timer hold to stop auto close timer while a safety loop or photo eye detects an obstacle.

• Cycle and access controls.

o Access control system terminals to interface with security systems card readers, and loop detectors.

o Emergency override sensor input for acoustic siren operated sensor.

• Auxiliary and hardware failsafe.

o Overrun delay failsafe input to prevent the motor from overrunning after operation.

o Magnetic lock power to secure the gate in the closed position.

o Status indicator output to power operation indicator lights.

NOTE: Must be compatible with Software House CCURE 9000.

Foundation and Footing:

Concrete Footing: Will be provided and constructed by Reclamation.

Bolts: NOTE: Vendor shall provide drawings or templates for installation of anchor bolts in support slab.

Additional Accessories Required:

• Cold Weather Package for temperature drops to below 35 degrees F (1 each gate: total 2)

• Loop Detectors: Provide detector system (exit loop) To allow free exit/safety, safety or close gate operation;

system to be factory wired inside electrical box and tested. (1 each gate: total 2)

• Reversing Edge: Provide manufactures standard reversing edge system. (1 each gate: total 2)

• Locks: magnetic lock secures gate in closed position. (1 each gate: total 2)

• Photo Eye: Used as a form of safety. (1 each gate: total 2)

• S.O.S.: Siren-Operated Acoustic Sensor for emergency vehicle override (Emergency access system) (1 each gate:

total 2)

• Heater-Electrical Box: Provide heater, including full box insulation to protect system for conditions to minus 70° F. (1 each gate: total 2)

Barrier System (Gates): Design to resist twist and to resist sway.

Type: Manufacturer's standard aluminum barrier (up to 25-foot-wide opening per gate leaf), nominal 3.125" by 2.875" diamond 6063-T5 alloy aluminum screen fabric welded both sides completely, with sway bracing. Leading member of an aluminum barrier 4" schedule 40 round tube, sway braces- 1 ¼ x 1 ¼ x 1/8 square tube uprights- 2 x 2 x .188 square tube. Sway braces bolted to barrier. Barriers with sway braces are designed to withstand 100 MPH wind load, or optional 150 MHP sway bracing.

Type: Custom barrier as indicated in statement of work above, with sway bracing.

Provide ONE stanchion (each gate) to contain free end for severe crash applications.

Required Accessories:

Child Guards: Provide child and small animal guard on secured side of operator.

Finish: Factory prime with Direct to Medal (DTM) epoxy and paint with acrylic urethane to resist corrosion.

The manufacturer's standard gray color #808080 or equivalent.

ITEM 4 – DROP ARM BEAM BARRIER SYSTEM (Consisting of 2 gates).

SITE 2 , GRAND COULEE REQUIREMENTS:

Provide Crash Certified Drop Arm Beam Barrier Systems with a minimum K12/M50 rating. The system consists of a crash beam, bearing assembly, hinge end support buttress and the hydraulic actuator, power unit, locking bolt with padlock provision, mounting hardware and other required options as described below for each gate.

2 EA, Delta Scientific Part DSC7000(H) or equivalent

• Barrier Construction: Barrier shall be a structural assembly containing a crash beam hinged at one end -lockable at the other, which can be raised and lowered hydraulically. When in the down locked position, the beam shall present a formidable obstacle to vehicles moving in either direction.

• Barrier Height: Height of the Barrier shall nominally be 33 inches (0,93 M) as measured from the roadway surface to the centerline of the crash beam.

• Barrier Clear Opening: The standard clear opening shall be 168 inches (14ft) as measured inside-to- inside of the hinge and locking buttress.

• Actuation: The Drop Arm Barricade shall be raised and lowered by means of a hydraulic cylinder driven by a Hydraulic Power Unit located within the cabinet at the hinge end Buttress.

Operator Unit Specifications:

• Hydraulic Power Motor: Unit shall consist of an electrically driven hydraulic pump, which shall pressurize a high-pressure manifold connected to a hydraulic accumulator. Electrically actuated valves shall be installed on the manifold to allow oil to be directed to the hydraulic cylinders to raise and lower the drop arm.

• Main Power. The electric motor driving the hydraulic pump shall be fed from ( 230/3/60). Motor shall be sufficiently sized for the expected number of Barricade operations.

• Manual Operation. A hand pump shall be furnished to allow the Barricades to be raised manually in the event of a power interruption.

• Construction. The hydraulic power unit and accessories shall be mounted and wired and mounted within the hinge end enclosure.

• Manual Locking Pin. The Barrier beam shall be provided with a locking pin with padlock locking point to secure the Barrier in the guard position. Locking pin should be able to accommodate a padlock with a shackle 7/16 inch (11MM).

Control and Logic Circuits:

• Weather Resistant HPU Enclosure. A lockable weather resistant enclosure shall be provided for the HPU. The design shall provide for easy access to the HPU for maintenance and emergency operation of the hydraulic system.

• Concrete Footing: will be provided and constructed by Reclamation.

• Bolts: Vendor shall provide drawings or templates for installation of anchor bolts in support slab.

Accessories Required Per Gate:

• Barrier system heater (1 each gate: total 2)

• Power unit mounted electrical disconnect. (1 each gate: total 2)

• Oil reservoir heater; Needs to be sized for the correct hydraulic pumping unit (HPU). (1 each gate: total 2)

• Three (3) flashing lights mounted to barrier for safety and visibility. (1 set each gate: total of 2 sets)

• Five (5) loop detector kits (5 Each gate: total of 10)

Additional Accessories Required for INBOUND Gate Only.

• Barricade fully down auxiliary limit switch.

• Barricade fully up auxiliary limit switch.

• Stop and go signal light LED 120v.

• 48" high post with 12" square mounting flange.

Finish and quality assurance:

• Exposed barrier surfaces shall be painted with gloss white, two-part epoxy high weather resistant paint. The drop arm beam shall be White and fitted with Red reflective tape across its front and back.

• Identification: A nameplate with manufacturer's name, model number, serial number and year built shall be located at the hinged end structure.

• Workmanship: The Barrier shall have a neat and workmanlike appearance.

• Finish: Coatings shall be checked against ordering information and shall be workmanlike in appearance.

Inspection:

Gate systems will be inspected upon delivery, including structural, interior, exterior and electrical components per specifications. Contractor will be responsible for any defects, discrepancies or damage discovered as a result of negligence in fulfilling contracted work, and any return shipping/transportation expense deemed necessary.

Assembly and Installation:

• Placement, set up, installation and final connection tasks to put gate systems in full operation will be completed by Reclamation staff and will not be required by contractor.

Contractor to provide Manufacturer installation instructions and electrical diagrams.

Other Requirements Required for Drop Arm Beam Barrier:

• Key lockable up/down push button station. (1 each gate: total 2)

• Barricade fully down auxiliary limit switch. (1 for inbound gate only: 1 total)

• Barricade fully up auxiliary limit switch. (1 for inbound gate only: 1 total)

• Barrier system heater. (1 each gate: total 2)

• Emergency manual operating system, Hand pump. (1 each gate: total 2)

• Power unit mounted electrical disconnect. (1 each gate: total 2)

• Oil reservoir heater, Beta units, 200W. (1 each gate: total 2)

• Flashing lights, Three. (1 each gate: total 2)

• Stop go signal light(s) LED 120V. (1 for inbound gate only: 1 total)

• 48" high post W/ 12" square mounting flange, white. (1 for inbound gate only: 1 total)

• Loop Detector kit. (5 each gate: 10 total)

Shipping:

Both the Barrier and Vertical Gate systems shall be completely pre-fabricated and pre-assembled and be crated or mounted on skids as necessary to prevent damage during shipping. The shipping container(s) shall be of sufficient structural integrity to enable the assembly to be lifted and transported by overhead crane or forklift without failure.

Deliverables (Provided after award)

-Installation Instructions: Provide manufacturer's installation instructions including any test procedures. Provide drawings or templates for installation of anchor bolts in support slab.

-Wiring Diagrams: Provide manufacturer's wiring diagrams for gate operator.

-Maintenance Data: Provide manufacturer's operators/owners and troubleshooting guide.

Clauses

52.212-4 CONTRACT TERMS AND CONDITIONS –COMMERCIAL PRODUCTS AND

COMMERCIAL SERVICES (RFO DEVATION MAR 2026)

---Addendum to 52.212-4---

52.252-6 AUTHORIZED DEVIATIONS IN CLAUSES (NOV 2020)

(a) The use in this solicitation or contract of any Federal Acquisition Regulation (48 CFR Chapter 1) clause with an authorized deviation is indicated by the addition of "(DEVIATION)" after the date of the clause.

(b) The use in this solicitation or contract of any Department of the Interior Acquisition Regulation (48 CFR Chapter 14) clause with an authorized deviation is indicated by the addition of "(DEVIATION)" after the name of the regulation.

(End of clause)

52.252-2 CLAUSES INCORPORATED BY REFERENCE (FEB 1998)

This contract incorporates one or more clauses by reference, with the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available. Also, the full text of a clause may be accessed electronically at this/these address(es):

Revolutionary FAR Overhaul (RFO): https://www.acquisition.gov/far-overhaul/far-part-deviation-guide Federal Acquisition Regulation: https://www.acquisition.gov/far Department of the Interior Acquisition Regulation: https://www.acquisition.gov/diar

The following clauses are hereby incorporated by reference:

52.203-17, Contractor Employee Whistleblower Rights (Nov 2023) ( 41 U.S.C. 4712); this clause does not apply to contracts of DoD, NASA, the Coast Guard, or applicable elements of the intelligence community—see FAR 3.900(a). (NOV 2023) 52.203-19, Prohibition on Requiring Certain Internal Confidentiality Agreements or Statements (Jan 2017) 52.204-13 – System for Award Management Maintenance (RFO Deviation MAR 2026)

52.209-6, Protecting the Government's Interest When Subcontracting with Contractors Debarred, Suspended, Proposed for Debarment, or Voluntarily Excluded. (RFO Deviation MAR 2026) ( 31 U.S.C. 6101 note).

52.209-10, Prohibition on Contracting with Inverted Domestic Corporations (RFO Deviation MAR 2016).

52.219-6, Notice of Total Small Business Set-Aside (RFO Deviation JAN 2026)

52.222-3, Convict Labor (RFO Deviation MAR 2026) (E.O.11755).

http://www.acquisition.gov/far http://www.acquisition.gov/diar https://www.acquisition.gov/far/part-52#FAR_52_203_17 https://uscode.house.gov/view.xhtml?req=granuleid:USC-prelim-title41-section4712&num=0&edition=prelim https://www.acquisition.gov/far/part-3#FAR_3_900 https://www.acquisition.gov/far/part-52#FAR_52_203_19 https://www.acquisition.gov/far/part-52#FAR_52_209_6 https://www.govinfo.gov/link/uscode/31/6101 https://www.acquisition.gov/far/part-52#FAR_52_209_10 https://www.acquisition.gov/far/part-52#FAR_52_222_3

52.222-19, Child Labor-Cooperation with Authorities and Remedies (RFO Deviation MAR 2026

52.222-35 Equal Opportunity for Veterans (RFO Deviation May 2026)

52.222-36, Equal Opportunity for Workers with Disabilities (RFO Deviation MAR 2026) ( 29 U.S.C. 793).

52.222-37 Employment Reports on Veterans (RFO Deviation May 2026).

52.222-50, Combating Trafficking in Persons (RFO Deviation MAR 2026) (22 U.S.C. chapter 78 and E.O. 13627).

52.222-90 Addressing DEI Discrimination by Federal Contractors (RFO Deviation APR 2026)

52.223-23 Sustainable Products (RFO Deviation MAR 2026)

52.225-1 Buy American Supplies (Oct 2022)

52.225-13, Restrictions on Certain Foreign Purchases. (Feb 2021)

52.226-8, Encouraging Contractor Policies to Ban Text Messaging While Driving (May 2024) ( E.O.

13513).

52.232-33, Payment by Electronic Funds Transfer-System for Award Management (Oct 2018) (31 U.S.C. 3332).

52.232-40, Providing Accelerated Payments to Small Business Subcontractors (Mar 2023) ( 31 U.S.C.

3903 and 10 U.S.C. 3801).

52.233-3, Protest After Award (RFO Deviation MAR 2026) (31 U.S.C. 3553).

52.233-4, Applicable Law for Breach of Contract Claim (RFO Deviation MAR 2026) (Public Laws 108-77 and 108-78 (19 U.S.C. 3805 note)).

52.244-6 Subcontracts for Commercial Products and Commercial Services. (RFO Deviation MAR 2026)

DOI-AAAP-0028 ELECTRONIC INVOICING AND PAYMENT REQUIREMENTS-INVOICE

PROCESSING PLATFORM (IPP) (MAR 2023)

Payment requests must be submitted electronically through the U. S. Department of the Treasury's Invoice Processing Platform System (IPP).

'Payment request' means any request for contract financing payment or invoice payment by the Contractor. To constitute a proper invoice, the payment request must comply with the requirements identified in the applicable Prompt Payment clause included in the contract, or the clause 52.212-4 Contract Terms and Conditions - Commercial Items included in commercial item contracts. The IPP website address is: https://www.ipp.gov.

Concurrent to submitting an invoice in IPP, the contractor may submit any supporting documentation to donald_richer@ios.doi.gov and bor-sha-Invoices@usbr.gov. Contractors are cautioned that supporting documentation e-mailed to the contracting officer and contract specialist must not conflict with the IPP submission. Conflicts between the IPP submission and supporting documentation may result in a delay in https://www.acquisition.gov/far/part-52#FAR_52_222_36 http://uscode.house.gov/view.xhtml?req=granuleid:USC-prelim-title29-section793&num=0&edition=prelim https://www.acquisition.gov/far/part-52#FAR_52_222_50 https://www.acquisition.gov/far/part-52#FAR_52_226_8 https://www.federalregister.gov/executive-order/13513 https://www.federalregister.gov/executive-order/13513 https://www.acquisition.gov/far/part-52#FAR_52_232_33 http://uscode.house.gov/view.xhtml?req=granuleid:USC-prelim-title31-section3332&num=0&edition=prelim https://www.acquisition.gov/far/part-52#FAR_52_232_40 https://uscode.house.gov/view.xhtml?req=granuleid:USC-prelim-title31-section3903&num=0&edition=prelim https://uscode.house.gov/view.xhtml?req=granuleid:USC-prelim-title31-section3903&num=0&edition=prelim https://uscode.house.gov/view.xhtml?req=granuleid:USC-prelim-title10-section3801&num=0&edition=prelim http://www.ipp.gov/ mailto:donald_richer@ios.doi.gov mailto:bor-sha-Invoices@usbr.gov approval and/or rejection of submitted invoices.

When e-mailing supporting documentation, the subject line of the email shall be formatted as follows:

Contract Number, Invoice Number, Contracting Officer's last name (e.g., 140R2018R00000_Invoice No.

1_Smith). The invoice shall be attached to the email and named using the following format: Contract Number, Contractor Name, Invoice Number, Invoice Amount (e.g., 140R2022R00000_World Test, Inc. - Inv. No. 1 - $5,678). Invoices shall not include information that would compromise Personally Identifiable Information, such as full social security numbers, dates of birth, etc. The final invoice shall be submitted and will be approved in accordance with payment terms and conditions contained in the contract, after all, if any, settlement actions are complete. The contractor must clearly identify the last payment as the ‘Final Invoice’.

The Contractor must use the IPP website to register access and use IPP for submitting requests for payment. The Contractor Government Business Point of Contact (as listed in SAM) will receive enrollment instructions via email from the Federal Reserve Bank of St. Louis (FRBSTL) within 3 - 5 business days of the contract award date. Contractor assistance with enrollment can be obtained by contacting the IPP Production Helpdesk via email IPPCustomerSupport@fiscal.treasury.gov or phone

(866) 973-3131.

If the Contractor is unable to comply with the requirement to use IPP for submitting invoices for payment, the Contractor must submit a waiver request in writing to the Contracting Officer with its proposal or quotation.

(End of Local Clause)

52.240-91 Security Prohibitions and Exclusions (RFO Deviation MAR 2026)

(a) Definitions. As used in this clause—

American Security Drone Act-covered foreign entity means an entity included on a list that the Federal Acquisition Security Council (FASC) develops and maintains and publishes in the System for Award Management (SAM) at https:// www.sam.gov (section 1822 of Pub. L. 118-31, 41 U.S.C. 3901 note prec.).

Backhaul means intermediate links between the core network, or backbone network, and the small subnetworks at the edge of the network (e.g., connecting cell phones/towers to the core telephone network). Backhaul can be wireless (e.g., microwave) or wired (e.g., fiber optic, coaxial cable, Ethernet).

Covered application means the social networking service TikTok or any successor application or service developed or provided by ByteDance Limited or an entity owned by ByteDance Limited.

Covered article, as defined in 41 U.S.C. 4713(k), means:

(1) Information technology, as defined in 40 U.S.C. 11101, including cloud computing services of all types;

(2) Telecommunications equipment or telecommunications service, as those terms are defined in section 3 of the Communications Act of 1934 (47 U.S.C. 153);

(3) The processing of information on a Federal or non-Federal information system, subject to the requirements of the Controlled Unclassified Information program (see 32 CFR part 2002); or

(4) Hardware, systems, devices, software, or services that include embedded or incidental information technology.

Covered foreign country means The People’s Republic of China.

Covered telecommunications equipment or services means—

(1) Telecommunications equipment produced by Huawei Technologies Company or ZTE Corporation (or any subsidiary or affiliate of such entities);

(2) For the purpose of public safety, security of Government facilities, physical security surveillance of critical infrastructure, and other national security purposes, video surveillance and telecommunications equipment produced by Hytera Communications Corporation, Hangzhou Hikvision Digital Technology Company, or Dahua Technology mailto:IPPCustomerSupport@fiscal.treasury.gov

Company (or any subsidiary or affiliate of such entities);

(3) Telecommunications or video surveillance services provided by such entities or using such equipment; or

(4) Telecommunications or video surveillance equipment or services produced or provided by an entity that the Secretary of Defense, in consultation with the Director of National Intelligence or the Director of the Federal Bureau of Investigation, reasonably believes to be an entity owned or controlled by, or otherwise connected to, the government of a covered foreign country.

Critical technology means—

(1) Defense articles or defense services included on the United States Munitions List set forth in the International Traffic in Arms Regulations under subchapter M of chapter I of title 22, Code of Federal Regulations;

(2) Items included on the Commerce Control List set forth in Supplement No. 1 to part 774 of the Export Administration Regulations under subchapter C of chapter VII of title 15, Code of Federal Regulations, and controlled—

(i) Pursuant to multilateral regimes, including for reasons relating to national security, chemical and biological weapons proliferation, nuclear nonproliferation, or missile technology; or

(ii) For reasons relating to regional stability or surreptitious listening;

(3) Specially designed and prepared nuclear equipment, parts and components, materials, software, and technology covered by part 810 of title 10, Code of Federal Regulations (relating to assistance to foreign atomic energy activities);

(4) Nuclear facilities, equipment, and material covered by part 110 of title 10, Code of Federal Regulations (relating to export and import of nuclear equipment and material);

(5) Select agents and toxins covered by part 331 of title 7, Code of Federal Regulations, part 121 of title 9 of such Code, or part 73 of title 42 of such Code; or

(6) Emerging and foundational technologies controlled pursuant to section 1758 of the Export Control Reform Act of 2018 (50 U.S.C. 4817).

FASC-prohibited unmanned aircraft system means an unmanned aircraft system manufactured or assembled by an American Security Drone Act—covered foreign entity.

FASCSA order means any of the following orders issued under the Federal Acquisition Supply Chain Security Act (FASCSA) requiring removing covered articles from executive agency information systems or excluding one or more named sources or named covered articles from executive agency procurement actions, as described in 41 CFR 201- 1.303(d) and (e):

(1) The Secretary of Homeland Security may issue FASCSA orders that apply to civilian agencies, to the extent not covered by paragraph (2) or (3) of this definition. This type of FASCSA order may be referred to as a Department of Homeland Security (DHS) FASCSA order.

(2) The Secretary of Defense may issue FASCSA orders that apply to the Department of Defense (DoD) and national security systems other than sensitive compartmented information systems. This type of FASCSA order may be referred to as a DoD FASCSA order.

(3) The Director of National Intelligence (DNI) may issue FASCSA orders that apply to the intelligence community and sensitive compartmented information systems, to the extent not covered by paragraph (2) of this definition. This type of FASCSA order may be referred to as a DNI FASCSA order.

Information technology, as defined in 40 U.S.C. 11101(6)—

(1) Means any equipment or interconnected system or subsystem of equipment, used in the automatic acquisition, storage, analysis, evaluation, manipulation, management, movement, control, display, switching, interchange, transmission, or reception of data or information by the executive agency, if the equipment is used by the executive agency directly or is used by a contractor under a contract with the executive agency that requires the use—

(i) Of that equipment; or

(ii) Of that equipment to a significant extent in the performance of a service or the furnishing of a product;

(2) Includes computers, ancillary equipment (including imaging peripherals, input, output, and storage devices necessary for security and surveillance), peripheral equipment designed to be controlled by the central processing unit of a computer, software, firmware and similar procedures, services (including support services), and related resources; but

(3) Does not include any equipment acquired by a Federal contractor incidental to a Federal contract.

Intelligence community, as defined by 50 U.S.C. 3003(4), means the following—

(1) The Office of the Director of National Intelligence;

(2) The Central Intelligence Agency;

(3) The National Security Agency;

(4) The Defense Intelligence Agency;

(5) The National Geospatial-Intelligence Agency;

(6) The National Reconnaissance Office;

(7) Other offices within the Department of Defense for the collection of specialized national intelligence through reconnaissance programs;

(8) The intelligence elements of the Army, the Navy, the Air Force, the Marine Corps, the Coast Guard, the Federal Bureau of Investigation, the Drug Enforcement Administration, and the Department of Energy;

(9) The Bureau of Intelligence and Research of the Department of State;

(10) The Office of Intelligence and Analysis of the Department of the Treasury;

(11) The Office of Intelligence and Analysis of the Department of Homeland Security; or

(12) Such other elements of any department or agency as may be designated by the President, or designated jointly by the Director of National Intelligence and the head of the department or agency concerned, as an element of the intelligence community.

Interconnection arrangements means arrangements governing the physical connection of two or more networks to allow the use of another’s network to hand off traffic where it is ultimately delivered (e.g., connecting a customer of telephone provider A to a customer of telephone company B) or sharing data and other information resources.

Kaspersky Lab-covered article means any hardware, software, or service that—

(1) Is developed or provided by a Kaspersky Lab-covered entity;

(2) Includes any hardware, software, or service developed or provided in whole or in part by a Kaspersky Lab-covered entity; or

(3) Contains components using any hardware or software developed in whole or in part by a Kaspersky Lab-covered entity.

Kaspersky Lab-covered entity means—

(1) Kaspersky Lab;

(2) Any successor entity to Kaspersky Lab, including any change in name, e.g., “Kaspersky”;

(3) Any entity that controls, is controlled by, or is under common control with Kaspersky Lab; or

(4) Any entity of which Kaspersky Lab has a majority ownership.

National security system, as defined in 44 U.S.C. 3552, means any information system (including any telecommunications system) used or operated by an agency or by a contractor of an agency, or other organization on behalf of an agency—

(1) The function, operation, or use of which involves intelligence activities; involves cryptologic activities related to national security; involves command and control of military forces; involves equipment that is an integral part of a weapon or weapons system; or is critical to the direct fulfillment of military or intelligence missions, but does not include a system that is to be used for routine administrative and business applications (including payroll, finance, logistics, and personnel management applications); or

(2) Is protected at all times by procedures established for information that have been specifically authorized under criteria established by an Executive order or an Act of Congress to be kept classified in the interest of national defense or foreign policy.

Roaming means cellular communications services (e.g., voice, video, data) received from a visited network when unable to connect to the facilities of the home network either because signal coverage is too weak or because traffic is too high.

Sensitive compartmented information means classified information concerning or derived from intelligence sources, methods, or analytical processes, which is required to be handled within formal access control systems established by the Director of National Intelligence.

Sensitive compartmented information system means a national security system authorized to process or store sensitive compartmented information.

Source means a non-Federal supplier, or potential supplier, of products or services, at any tier.

Subsidiary means an entity in which more than 50 percent of the entity is owned directly by a parent corporation or through another subsidiary of a parent corporation.

Substantial or essential component means any component necessary for the proper function or performance of a piece of equipment, system, or service.

Unmanned aircraft means an aircraft that is operated without the possibility of direct human intervention from within or on the aircraft (49 U.S.C. 44801(11)).

Unmanned aircraft system means an unmanned aircraft and associated elements (including communication links and the components that control the unmanned aircraft) that are required for the operator to operate safely and efficiently in the national airspace system (49 U.S.C. 44801(12)).

(b) Prohibitions on providing or using specific products or services in performance of contract. Unless a waiver or exception applies, the Contractor is prohibited from providing any products or services to the Government or using in the performance of the contract any of the following:

(1) A covered application on any information technology owned or managed by the Government, or on any information technology used or provided by the Contractor under this contract, including equipment provided by the Contractor’s employees (section 102 of Division R of the Consolidated Appropriations Act, 2023 (Pub. L. 117-328));

(2) A Kaspersky Lab-covered article (Section 1634 of Division A of the National Defense Authorization Act for Fiscal Year 2018 (Pub. L. 115-91));

(3) Covered telecommunications equipment or services used as a substantial or essential component of any system, or as critical technology as part of any system (paragraphs (a)(1)(A) of section 889 of the John S. McCain National Defense Authorization Act for Fiscal Year 2019 (Pub. L. 115-232)). This does not prohibit contractors from providing—

(i) A service that connects to the facilities of a third-party, such as backhaul, roaming, or interconnection arrangements; or

(ii) Telecommunications equipment that cannot route or redirect user data traffic or cannot permit visibility into any user data or packets that such equipment transmits or otherwise handles.

(c) Prohibition on unmanned aircraft systems manufactured or assembled by American Security…