- Solicitation number
- 36C26123R0012
About this file
This document contains construction drawings and specifications for the repair and renovation of a VA parking structure located in Honolulu, Hawaii. Key details include renovation of the existing 200,000 square foot parking structure building to update the visual appearance, including architectural and plumbing work. Mechanical, electrical, and structural engineering services are also required. The work must comply with applicable VA standards and codes. Bids for the project are being solicited under Solicitation Number 36C26123R0012 by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 21. The response due date and award date are not provided.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G Y M
AB
D
F G
H
P O O L
C
MAIN
HOSPITAL
PATTERSON RD
K R U K O W S K I R D
WARD RD
E
ARCHITECTURAL
SPEES DESIGN BUILD
625 1ST AVE, STE 301
SEATTLE, WA 98104
PHONE: (206) 590-2118
DESIGN TEAM
STRUCTURAL
REID MIDDLETON
PLUMBING
MECHANICAL
INSYNERGY
728 134TH ST SW, STE 200
EVERETT, WA 98204
PHONE: (425) 741-3800
828 FORT STREET MALL STE 500,
HONOLULU, HI, 96813
PHONE: (808) 521-3773
INSYNERGY
828 FORT STREET MALL STE 500,
HONOLULU, HI, 96813
PHONE: (808) 521-3773
PROJECT INFORMATION
STATE:
JURISTICTION:
OWNER:
CODE ANALYSIS
PROJECT DESCRIPTION
THE PROPOSED DESIGN SHALL RENOVATE
EXISTING PARKING STRUCTURE BLDG 32. THIS
INCLUDES ARCHITECTURAL AND PLUMBING
RENOVATIONS REQ'D FOR A RENEWED VISUAL
LOOK TO THE STRUCTURE.
APPLICABLE BUILDING
BUILDING 32
APPROXIMATE SQUARE FOOTAGE
200,000 SF
HAWAII
HONOLULU
VA PACIFIC ISLANDS
HEALTH CARE SYSTEM
REFERENCE DOCUMENTS
APPLICABLE VA STANDARDS
DESIGN AND CONSTRUCTION PROCEDURES (PG 18-3), TOPIC 1 - CODES, STANDARDS & EXECUTIVE ORDERS
SEPTEMBER 2013
GENERAL NOTES
1. COORDINATE WORK WITH ALL CONTRACT DOCUMENTS, INCLUDING BUT NOT LIMITED TO DRAWINGS &
SPECIFICATIONS.
2. SPECIFICATIONS SHALL SUPERSEDE DRAWINGS IN THE CASE OF ANY CONFLICTING INFORMATION.
VERIFY WITH VA COR BEFORE PROCEEDING.
3. THE CONTRACTOR AND ANY SUB CONTRACTORS SHALL FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND PROJECT REQUIREMENTS PRIOR TO SUBMITTING A BID OR BEGINNING WORK. NO ALLOWANCES WILL BE MADE ON BEHALF OF THE CONTRACTOR OR SUB-CONTRACTORS FOR FAILURE
TO VISIT THE SITE.
4. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS BEFORE BEGINNING WORK. ANY CONFLICTS BETWEEN EXISTING CONDITIONS AND THE CONTRACT DOCUMENTS SHALL BE BROUGHT
IMMEDIATELY TO THE ATTENTION OF THE COR.
5. ALL WORK SHALL BE PERFORMED WITH A HIGH-LEVEL OF WORKMANSHIP.
6. THE CONTRACTOR SHALL VERIFY ALL PRODUCT TYPES AND QUANTITIES DURING SITE WALK
THROUGH, PRIOR TO PURCHASING ANY MATERIALS, EQUIPMENT, PRODUCTS OR LABOR.
7. THE CONTRACTOR SHALL VERIFY AND COORDINATE WITH ALL INSTALLERS TO ENSURE COMPLIANCE
WITH THE CONTRACT DOCUMENTS.
APPLICABLE PUBLICATIONS
AS AN AGENCY OF THE FEDERAL GOVERNMENT, THE VA IS NOT SUBJECT TO LOCAL IMPOSITIONS OF CODE ENFOREMENT PROCEDURES ( DRAWING REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC). THE VA
SHALL FUNCTION AS THE AUTHORITY HAVING JURISTICTION (AHJ).
VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD APPLICATION
GUIDE AND OTHER GUIDEANCE ON THE TECHNICAL INFORMATION LIBRARY (TIL). SEE ABOVE.
INTERNATIONAL BUILDING CODE (IBC) 2018.
INTERNATIONAL EXISTING BUILDING CODE (IEBC) 2018.
NATIONAL FIRE PROTECTION AGENCY (NFPA) 101 LIFE SAFETY CODE. NFPA 101 TAKES PRECEDENCE OVER
IBC.
NFPA NATIONAL FIRE CODES, WITH THE EXCEPTION OF NFPA 5000 AND NFPA 900.
OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS.
VA SEISMIC DESIGN REQUIREMENTS, H-18-8.
NATIONAL ELECTRICAL CODE (NEC).
INTERNATIONAL PLUMBING CODE (IPC).
EXECUTIVE ORDER 13423: STRENGTHEING FEDERAL ENVIRONMENTAL, ENERGY AND TRANSPORTATON
MANAGEMENT.
THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED IN THE GENERAL REQUIREMENTS
SECTION 01 01 0 OF THE VA MASTER CONSTRUCTION SPECIFICATION.
VAMC APPROVED HARDWARE LOCKING STANDARDS
AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI), AS REFERENCED.
AMERICAN SOCIETY FOR TESTING MATERIALS (ASTM), AS REFERENCED.
VA PACIFIC ISLANDS HEALTH CARE SYSTEM,
HONOLULU, HAWAII
BUILDING WITHIN SCOPE OF THIS PROJECT
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
G-001
COVER & DRAWING INDEX
SPEES DESIGN BUILD
625 1ST AVE, STE 301
SEATTLE, WA 98104
(206) 590-2118
RAY SPEES
REPAIR VA PARKING STRUCTURE
EXTERIOR BLDG 32
VA PACIFIC ISLANDS HEALTH CARE SYSTEM,
HONOLULU, HAWAII
459-19-002
01/27/2022 EM AJ
CONSTRUCTION
DOCUMENTS
REPAIR VA PARKING STRUCTURE EXTERIOR BLDG 32
VA PACIFIC ISLANDS HEALTH CARE SYSTEM, HONOLULU, HAWAII
PROJECT #: 459-19-002
NTS
LOCATION PLAN
NTS
VICINITY MAP
DRAWING INDEX
PAGE # SHEET # SHEET NAME
GENERAL
1 OF 23 G-001 COVER & DRAWING INDEX
2 OF 23 GS101 ARCHITECTURAL SITE PLAN
ARCHITECTURAL
3 OF 23 A-001 ARCHITECTURAL SYMBOLS & ABBREVIATIONS
4 OF 23 AD100 LEVEL 4 - DEMO FLOOR PLAN
5 OF 23 AD101 LEVEL 4 - DEMO ROOF PLAN
6 OF 23 AD102 LEVEL 4 - DEMO REFLECTED CEILING PLAN
7 OF 23 AE100 LEVEL PB - FLOOR PLAN
8 OF 23 AE101 LEVEL P1 - FLOOR PLAN
9 OF 23 AE102 LEVEL P2 - FLOOR PLAN
10 OF 23 AE103 LEVEL P3 - FLOOR PLAN
11 OF 23 AE104 LEVEL P4 - FLOOR PLAN
12 OF 23 AE105 ROOF PLAN
13 OF 23 AC102 REFLECTED CEILING PLAN
14 OF 23 AE201 BUILDING ELEVATIONS
15 OF 23 AE202 BUILDING ELEVATIONS
16 OF 23 AE401 ENLARGED ROOF PLANS
17 OF 23 AC411 ENLARGED REFLECTED CEILING PLANS
18 OF 23 A-501 ROOFING AND CONCRETE DETAILS
19 OF 23 A-602 DOOR SCHEDULE, TYPES & DETAILS
20 OF 23 AW001 SIGNAGE SCHEDULE & LOCATIONS
21 OF 23 AW002 IN 01.05, IN 01.10, IN 08.01
MECHANICAL
22 OF 23 MP101 OVERALL MECHANICAL ROOF PLAN, NOTES AND LEGEND
23 OF 23 MP201 ENLARGED ROOF MECHANICAL PLAN
Revisions: Date:
TRUE
NORTH
anaj Image
VHAHONTangR Callout E-Wing For Pre-Bid meeting
VHAHONTangR Callout Then Parking Structure Bldg 32 for Pre-Bid site visit. Meet on the 1st floor outside of the elevators.