Site_Concept.pdf
PDF 344 KB Posted
- Attached to
- Hazardous Waste Storage Unit
- Solicitation number
- IFB-080-2821001-MG
- Issued by
- Orange County, San Francisco City, California
About this file
This document is a site concept design plan for a Hazardous Material Storage Unit prepared by Wood (formerly AMEC Foster Wheeler E&C Services) for a County of Orange, California public works project. The design depicts a detailed site layout for a four-compartment hazardous materials storage unit, featuring an 8-foot high chainlink security fence, 48-inch high steel bollards around the perimeter, and a 5-foot wide double chainlink lockable gate. The concept plan includes aerial site views, precise dimensional measurements, and technical specifications for the storage unit's placement, with underground electrical and alarm monitoring services integrated into the design.
The site concept addresses multiple regulatory requirements, including compliance with CALFire, OSHA, EPA, and NFPA standards for hazardous material storage. The design incorporates fire-rated construction boundaries, with 2-hour and 4-hour rated sections specified. The storage unit will be anchored to a cast-in-place concrete foundation, with careful consideration given to site utilities, structural requirements, and temperature control. The document is marked "Not for Construction" and "For Review", indicating it is a preliminary design concept that will undergo further refinement before implementation of the hazardous waste storage unit project.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Hazardous_Waste_Storage_Unit.pdf | ||
| MODEL_CONTRACT_IFB-080-2821001-MG_Hazardous_Waste_Storage_Unit.pdf | ||
| Building_Concept.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N O
P A
R K
IN
G
CR
EXIT EXIT
EXIST.
F.H.
EXIST. F.H.
C L
C.L.
FENCE
E X
IT APPROXIMATE BOUNDARY FOR 2-HOUR
FIRE RATED CONSTRUCTION
APPROXIMATE BOUNDARY FOR 4-HOUR
FIRE RATED CONSTRUCTION
A011
46'-0"
9'-0" 9'-0" 9'-0"
E Q
E Q
E Q
E Q
E Q
5'-0" 36'-0" 5'-0"
E Q
E Q
E Q
E Q
E Q
'-0
5' -6
9'
-6
'-0
48" HIGH GROUT FILLED STEEL BOLLARD,
TYPICAL AT FENCE PERIMETER EXPOSED
TO VEHICULAR TRAFFIC. 6 FT ON-
CENTER MAX SPACING.
8FT HIGH CHAINLINK SECURITY FENCE
5FT WIDE DOUBLE CHAINLINK
GATE, LOCKABLE, TYP
FOUR COMPARTMENT HAZARDOUS
MATERIAL STORAGE UNIT ANCHORED TO
CAST-IN-PLACE CONCRETE FOUNDATION
OUTLINE OF CAST-IN-PLACE CONCRETE
FOUNDATION
TENTHS 0 INCHES 1 3 4 5 6 7 8 9 102 EIGHTHS 0 MM 10 20 30 40 50 60 70 80 90 100
D
C
B
A
8 7 6 5 4 3 2 1
REV DDMMMYY REVISION / ISSUE DESCRIPTION DRN CHK APP APP APP APP
REF NUMBER TITLE
REFERENCES
PROJECT PHASE
UNLESS OTHERWISE AGREED IN A WRITTEN CONTRACT BETWEEN WOOD AND ITS CLIENT, THIS
DOCUMENT: (I) CONTAINS INFORMATION, DATA AND DESIGN THAT IS CONFIDENTIAL AND MAY NOT
BE COPIED OR DISCLOSED; AND (II) MAY BE USED BY THE CLIENT ONLY IN THE CONTEXT AND FOR
THE EXPRESS PURPOSE FOR WHICH IT WAS INTENDED. ANY USE OF, OR RELIANCE ON, THIS
DOCUMENT BY ANY THIRD PARTY IS AT THAT PARTY'S SOLE RISK.
STAMP/SEAL
CLIENT PROJECT MGR. DEPARTMENT MGR. PROJECT MGRS.
PROJECT NO. ACTIVITY NO.
SCALE PACKAGE CODE
BY MMDDDYY
DSN
DRN
CHK
APP
SUBJECT
CLIENT DWG. NO.
DRAWING NO.
AREA
30 PATEWOOD DRIVE, SUITE 200 - GREENVILLE, SC 29615 (864) 458-3600
NOT FOR
CONSTRUCTION
FOR REVIEW
WORK SAFELY
COPYRIGHT © 2021
WOOD, DOING BUSINESS AS AMEC FOSTER WHEELER E&C SERVICES
F
E
D
C
B
A
REV DDMMMYY REVISION / ISSUE DESCRIPTION DRN CHK APP APP APP APP
As indicated
B
HAZMAT UNIT CONCEPT
Project Number Designer
Author
Checker
Approver
SITE OPTIONS CONCEPT
D-ARC-SK-A011
SCALE = 1" = 30'-0"A011
SITE CONCEPT PLAN1
SCALE = 1" = 10'-0"A011
A-SP02 - Callout 12
A 31AUG22 PROGRESS REVIEW MPK --- --- --- --- ---
B 11NOV22 HAZMAT UNIT CONCEPT MPK --- --- --- --- ---
UNDERGROUND ELECTRICAL
AND ALARM MONITORING
SERVICES.
| Sheets |
| A011 - SITE OPTIONS CONCEPT |
File details come from the government source that posted it. Updated .