This document is a standard details reference guide for corrosion control specifications issued by the Washington Suburban Sanitary Commission (WSSC) in Maryland. The file serves as a technical standard manual for water infrastructure projects and contains comprehensive tables of contents and detailed drawings for corrosion prevention and protection measures related to water main construction and connections. The document covers approximately 59 standard detail specifications organized into seven major sections addressing ductile iron pipe bonding, thermite welding, sacrificial anode installation, insulated flange joints, test stations, field-applied coatings, and PVC pipe anode protection systems. These standards apply to the construction of water house connections ranging from 1 inch to 2 inches in diameter and sewer house connections from 4 inches to 6 inches in diameter, as referenced in the related Area Water and Sewer House Connection contract solicitation for approximately 11,000 linear feet of water connections and 2,600 linear feet of sewer connections across Prince George's and Montgomery Counties, Maryland.
The document establishes mandatory technical specifications and installation procedures for contractors performing water and sewer infrastructure work under WSSC projects. These corrosion control details are essential reference materials for bidders and contractors responding to the May 26, 2026 deadline for the Area Water and Sewer House Connection solicitation. The specifications address critical protective measures including bonding of metallic components, cathodic protection through sacrificial anodes, insulating flange installations to prevent galvanic corrosion, and proper test station placement and configuration. Contractors must comply with these WSSC standard details when submitting sealed responses through the agency's eProcurement Portal, ensuring that all work related to the approximately 150 new service installations meets established corrosion control standards and specifications.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION VI
CORROSION
DETAILS
SEPTEMBER 2021
Page C-1
Table of Contents WSSC STANDARD DETAILS
SECTION VI- CORROSION DETAILS
TABLE OF CONTENTS
TITLE NUMBER
Ductile Iron Pipe Joint Bond C/1.0
Ductile Iron Pipe Bonding of Fitting Joints C/1.1
Ductile Iron Pipe Bonding of Fitting Joints C/1.1a
Ductile Iron Mechanical Joint Valve Bonding C/1.2
Bonding of Existing Pipe with Cathodic Protection when Connecting to new Metallic Water Mains C/1.2a
Ductile Iron Pipe Bonding Around Valve Vault C/1.3
Ductile Iron Pipe Bonding Around Manhole C/1.3a
Mechanical Coupling Joint Bond C/1.4
Fire Hydrant Bonding C/1.6
Attachment of Bonding Wires for Crossing Water Pipelines C/1.7
Attachment of Bonding Wires for Parallel Water Pipelines C/1.7a
Pipeline Junction box Detail (Typical) C/1.7b
Separator to Avoid Metallic Contact on Crossing Pipes C/1.9
Thermite Weld Wire Connection C/2.0
Thermite Weld Detail C/2.1
Sacrificial Anode Installation C/2.2
Plan View of Sacrificial Anode Installation and Test Station Placement C/2.2a
Typical Test Station Installation C/2.2b
Splice Detail Anode Leader to the Header Cable C/2.3
Hydrant Test Station (Type C) C/2.5
SEPTEMBER 2021
Page C-2
Test Station at Mechanical / Push-on Cap / Plug C/2.6
Insulated Flange Joint Detail C/3.0
Coating of Insulating Flange Detail C/3.0a
Insulating Flange Test Station (IJ) C/3.0b
Insulating Flange Test Station with Anodes (IJ) C/3.0c
Valve to Main Insulated Flange Joint (Restrained) C/3.1
Valve to Main Insulated Flange Joint (Unrestrained) C/3.2
PVC Insulating Spool for Branch Lines for 12” and Smaller C/3.2a
Insulating Spool C/3.2b
PCCP x DIP Tie-In Detail with Insulating Joint C/3.3
PCCP x DIP Tie-In Detail with Insulating Joint and Test Lead Wires C/3.4
Insulated Joint for Copper Pipe Service Connections (2” or less) C/3.5
Insulated Tie Rods on Insulated Flange Joint C/3.6
Flush-Mounted Test Station C/4.0
Flush Mounted Test Station Terminal Block C/4.0a
Flush Mounted Test Station Terminal Block for Bonded Pipelines C/4.0b
Pipe Mounted Above Ground Test Station C/4.2
Test Station with Reference Cell C/4.5
IR Drop Test Station for Ductile Iron Pipe C/4.6
Test Station at Foreign Pipeline Crossing C/4.7
Field Applied Coatings When Connecting to Existing CIP and DIP Water Mains C/5.0
Field Applied Coatings When Connecting to Existing PCCP Water Mains C/5.1
3” Thru 12” Ductile Iron Water House Connection Insulating Joint C/5.2
Joint Coating Detail C/6.0
AUGUST 2020
Page C-3
PVC AWWA C-900 Pipe 12-inch Anode Protection Valve C/7.1
PVC AWWA C-900 Pipe 4-inch to 12-inch Tapping Sleeve and Valve C/7.2
PVC AWWA C-900 Pipe 4-inch to 12-inch Anode Protection for Bends C/7.3
PVC AWWA C-900 Pipe 4-inch to 12-inch Anode Protection for Tee C/7.4
PVC AWWA C-900 Pipe 4-inch to 12-inch Anode Protection for Cross C/7.5
PVC AWWA C-900 Pipe 4-inch to 12-inch Anode Protection for Cap C/7.6
PVC AWWA C-900 Pipe 4-inch to 12-inch Anode Protection for MJ Solid Sleeve C/7.7
PVC AWWA C-900 Pipe 4-inch to 12-inch Anode Protection for Water House Connections C/7.9
PVC AWWA C-900 Pipe 4-inch to 12-inch Anode Protection for Restrain Joint C/7.10
PVC AWWA C-900 Pipe 4-inch to 12-inch Anode Protection for Service Saddle C/7.11
PVC AWWA C-900 Pipe 4-inch to 12-inch Single Anode Placement C/7.12
PVC AWWA C-900 Pipe 4-inch to 12-inch Multiple Anode Placement C/7.13
| 1 - C 1.0 |
| 2 - C 1.1 |
| 3 - C 1.1a |
| 4 - C 1.2 |
| 5 - C 1.2a |
| 6 - C 1.3 |
| 7 - C 1.3a |
| 8 - C 1.4 |
| 9 - C 1.6 |
| 10 - C 1.7 |
| 11 - C 1.7a |
| 12 - C 1.7b |
| 13 - C 1.9 |
| 14 - C 2.0 |
| 15 - C 2.1 |
| 16 - C 2.2 |
| 17 - C 2.2a |
| 18 - C 2.2b |
| 19 - C 2.3 |
| 20 - C 2.5 |
| 21 - C 2.6 |
| 22 - C 3.0 |
| 23 - C 3.0a |
| 24 - C 3.0b |
| 25 - C 3.0c |
| 26 - C 3.1 |
| 27 - C 3.2 |
| 28 - C 3.2a |
| 29 - C 3.2b |
| 30 - C 3.3 |
| 31 - C 3.4 |
| 32 - C 3.5 |
| 33 - C 3.6 |
| 34 - C 4.0 |
| 35 - C 4.0a |
| 36 - C 4.0b |
| 37 - C 4.2 |
| 38 - C 4.5 |
| 39 - C 4.6 |
| 40 - C 4.7 |
| 41 - C 5.0 |
| 42 - C 5.1 |
| 43 - C 5.2 |
| 44 - C 6.0 |
| 45 - C 7.0 |
| 46 - C 7.1 |
| 47 - C 7.2 |
| 48 - C 7.3 |
| 49 - C 7.4 |
| 50 - C 7.5 |
| 51 - C 7.6 |
| 52 - C 7.7 |
| 53 - C 7.8 |
| 54 - C 7.9 |
| 55 - C 7.10 |
| 56 - C 7.11 |
| 57 - C 7.12 |
| 58 C 7.13 |
| 59 C 7.14 |