Section_V_-_Blocking_Details.pdf

PDF 1 MB Posted

Attached to
Area Water and Sewer House Connection
Solicitation number
104581
Issued by
Prince George's County, Barclay Town, Maryland

About this file

This is a standard technical details document from the Washington Suburban Sanitary Commission (WSSC) in Maryland, providing specifications for blocking and thrust support systems used in water and sewer infrastructure construction. The document, dated September 2021, serves as a reference guide for engineers and contractors working on WSSC projects and contains a table of contents listing thirteen standard detail specifications. These specifications cover thrust blocks for various pipe configurations including horizontal bends, tees, tapping sleeves, plugs, and caps; anchorage methods for vertical bends; strapping procedures for valves, fire hydrants, and mechanical couplings; and quick harnessed connection methods for different pipe materials including ductile iron, cast iron, prestressed concrete cylinder pipe, and pipe with weld-on thrust rings. The document is organized sequentially with detail numbers ranging from B/1.0 through B/3.3 to facilitate easy reference during construction and design phases.

This technical standards document does not address pricing, set-asides, contract terms, funding sources, or other commercial provisions. Instead, it functions as a technical reference manual establishing uniform construction methodologies and specifications that contractors must follow when performing work under WSSC contracts, such as the Area Water and Sewer House Connection solicitation. The specifications ensure consistency, structural integrity, and compliance with WSSC engineering standards across multiple construction projects throughout Prince George's and Montgomery Counties, Maryland.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION V

BLOCKING

DETAILS

SEPTEMBER 2021

Page B-1

Table of Contents WSSC STANDARD DETAILS

SECTION V-BLOCKING DETAILS

TABLE OF CONTENTS

TITLE NUMBER

Thrust Blocks for Horizontal Bends B/1.0

Thrust Blocks for Tees and Tapping Sleeves B/1.3

Thrust Blocks for Plugs and Caps B/1.4

Anchorage for 1/32, 1/16 and 1/8 Upper Vertical Bends B/1.7

Thrust Blocks for 11-1/40, 22-1/20 and 450 Lower Vertical Bends B/1.8

Method of Strapping Valve to Main B/2.0

Method of Restraining Fire Hydrant to Main for 12-inch smaller B/2.1

Method of Strapping Hydrant to Main for 14-ind larger B/2.2

Method of Strapping Mechanical Coupling in Vaults and Facilities B/3.0

Quick Harnessed Connection to Thrust Blocking for Ductile Iron and Cast Iron Pipe B/3.1

Quick Harnessed Connection to Thrust Blocking for Existing Prestressed B/3.1b Concrete Cylinder Pipe

Quick Block Direct Thrust B/3.2

Concrete Thrust Block with Weld-On Thrust Ring on Ductile Iron Pipe B/3.3

1 - B 1.0
2 - B 1.3
3 - B 1.4
4 - B 1.7
5 - B 1.8
6 - B 2.0
7 - B 2.1
8 - B 2.2
9 - B 3.0
10 - B 3.1
11 - B 3.1b
12 - B 3.2
13 - B 3.3

File details come from the government source that posted it. Updated .