Section_III_-_Sewer_Details.pdf

PDF 3 MB Posted

Attached to
Area Water and Sewer House Connection
Solicitation number
104581
Issued by
Prince George's County, Barclay Town, Maryland

About this file

This is a Standard Details technical specification document issued by the Washington Suburban Sanitary Commission (WSSC) in Maryland, detailing sewer infrastructure requirements and installation standards for a contract opportunity related to water and sewer house connections. The document provides comprehensive technical specifications for sewer system components, including precast concrete manholes ranging from 48 inches to 96 inches in diameter, manhole frames and covers, pipe-to-manhole connections, drop manholes, cleanout installations, sewer house connections in 4-inch and 6-inch sizes, backwater valve assemblies, and repair methods for damaged pipe. The contract opportunity involves constructing approximately 11,000 linear feet of 1-inch through 2-inch water house connections, approximately 2,600 linear feet of 4-inch through 6-inch sewer house connections, and approximately 335 linear feet of 1-inch pressure sewer house connections for approximately 150 new service installations across multiple locations in Prince George's and Montgomery Counties, Maryland on an annual basis. Sealed responses must be submitted via WSSC's eProcurement Portal at https://procurement.opengov.com/portal/wsscwater prior to 2:00 pm on Tuesday, May 26, 2026, with late responses not being accepted.

The Standard Details document serves as a reference guide containing 49 detailed specifications and load charts organized by section number, covering design, materials, installation methods, and technical requirements for all sewer-related components. These specifications establish uniform standards for WSSC projects and ensure compliance with applicable industry standards such as AWWA C900/905 for PVC pipe and other referenced material and installation protocols. No pricing terms, set-asides, incumbent information, or funding source details are specified within this technical specification document.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION III

SEWER

DETAILS

SEPTEMBER 2021

Page S-1

Table of Contents WSSC STANDARD DETAILS

SECTION III - SEWER DETAILS

TABLE OF CONTENTS

TITLE NUMBER

48-inch Diameter Precast Concrete Manhole S/1.0

60-inch Diameter Precast Concrete Manhole S/1.1

72-inch, 84-inch and 96-inch Diameter Precast Concrete Manhole S/1.2

Precast Top Slab for 48-inch and 60-inch Diameter Precast Concrete Manholes S/1.3

Precast Concrete manhole with Fall Prevention System S/1.4

Precast Concrete Manhole Built Over Existing Sewer - Type II S/2.1

Precast Manhole Built On Existing PVC or DI Pipe S/2.2

Pipe to Existing Brick Manhole Connection For Using DIP, RCP or S/3.0 AWWA C900/905 PVC Only

Bentonite Application for Grouted Pipe to Manhole Connection S/3.01

Pipe to Manhole Connection for Deep Manhole S/3.02

Pipe to Manhole Connection for 12-inch and Smaller Pipes on Steep Grades S/3.03

Drop Manhole Type "A" Drop for Pipes 12-inch and Smaller S/3.1

Drop Manhole Type "B" Drop for Pipes 12-inch and Smaller S/3.1a

Inside Drop Connection for Precast Concrete Manholes S/3/1b

Inside Drop Connection for Precast Concrete Manholes (Fiberglass Drop Bowl) S/3.1c

Shallow Manhole Precast Concrete S/3.2

Plan of Typical Channelization of Mainline Sewer Manholes S/3.3

Manhole steps in Channels for Sewer 36-Inch and Larger S/3.4

Abandonment of Pipe at Manhole S/3.5

Manhole and Sewer Abandonment S/3.6

Page S-2

15-inch and Larger Sewer Pipe to Manhole Connection S/3.7

Adjusting Rings for 22-inch Opening Watertight Manhole Frame and Cover S/4.0

Adjusting Rings for 22-inch Opening Old Type Standard Manhole Frame and Cover S/4.1

Final Setting Anchoring 24-inch Watertight Frame and Cover to Manhole Wall S/4.2

Interim Setting Anchoring 24-inch Watertight Frame and Cover to Manhole Cone S/4.2a

24-inch Precast Concrete Manhole Transition Ring S/4.21

24-inch Precast Concrete Manhole Sloped Transition Ring S/4.22

Anchoring 30-inch and 36-inch Manhole Frame and Cover to Manhole Wall S/4.3

Standard Cleanout Installation for 4-inch and 6-inch Sewer House Connections S/5.0

Trenchless Cleanout System for Installation on Existing 4-inch and 6-inch Sewer S/5.0a House Connections

Cleanout Cover Assembly for 4-inch Cleanouts S/5.1

Cleanout (Lamphole) Cover Assembly for 6-inch Cleanouts S/5.2

4-inch and 6-inch Drop House Connections to Sewer Main S/6.0

4-inch and 6-inch Drop House Connections to Manhole S/6.1

4-inch and 6-inch Sewer House Connections S/6.2

4-inch and 6-inch PVC House Connections and Fittings S/6.3

4-inch and 6-inch DIP or PVC AWWA C900 House Connections and Fittings S/6.3a

4-Inch Radial Multiple Sewer House Connections Installation and Channelization S/6.4

Parallel Multiple 4-Inch Sewer House Connection Installation S/6.5

Transition Manhole Force Main to Gravity Sewer S/6.6

4-inch and 6-inch Sewer House Connection Within WSSC Right of Way S/6.7

4-inch and 6-inch Sewer House Connections Terminating at the Property Line S/6.8

Backwater Valve Assembly for 4-Inch Existing Sewer House Connections S/6.9

Backwater Valve (Lamphole) Cover Assembly S/6.9a

Page S-3

Replacement of Existing Backwater Valve Assembly in Existing Brick Manhole S/6.9b

Method of Repairing Cracked Concrete or Vitrified Clay Sewer Pipe S/7.2

Method of Repairing Cracked Concrete or Vitrified Clay Sewer Pipe S/7.2a

Load Schedule for R.C. Pipes S/8.0

Polyvinyl Chloride (PVC) Gravity Sewer Pipe Load Chart S/8.1

1 - S 1.0
2 - S 1.1
3 - S 1.2
4 - S 1.3
5 - S 1.4
6 - S 2.1
7 - S 2.2
8 - S 3.0
9 - S 3.01
10 - S 3.02
11 - S 3.03
12 - S 3.1
13 - S 3.1a
14 - S 3.1b
15 - S 3.1c
16 - S 3.2
17 - S 3.3
18 - S 3.4
19 - S 3.5
20 - S 3.6
21 - S 3.7
22 - S 4.0
23 - S 4.1
24 - S 4.2
25 - S 4.2a
26 -S 4.21
27 - S 4.22
28 - S 4.3
29 - S 5.0
30 - S 5.0a
31 - S 5.1
32 - S 5.2
33 - S 6.0
34 - S 6.1
35 - S 6.2
36 - S 6.3
37 - S 6.3a
38 - S 6.4
39 - S 6.5
40 - S 6.6
41 - S 6.7
42 - S 6.8
43 - S 6.9
44 - S 6.9a
45 - S 6.9b
46 - S 7.2
47 - S 7.2a
48 - S 8.0
49 - S 8.1

File details come from the government source that posted it. Updated .