View the file

Other files

File Type Posted
AMENDMENT 1 FA863022R4000 0001 DATED 2 DEC 2021.pdf PDF
INDUSTRY QUESTIONS REGARDING FA863022R4000 PROS VI 2 Dec 2021 REV 6.pdf PDF
AMENDMENT TO RFP REGARDING FA863022R4000 PROS VI 2 DEC 2021 Rev 3.pdf PDF
Section J Attachment 10 Instructions to Offerors 29 Nov 21 REV 4.pdf PDF
INDUSTRY QUESTIONS REGARDING FA863022R4000 PROS VI 29 NOV 2021 REV 5.pdf PDF
INDUSTRY QUESTIONS REGARDING FA863022R4000 PROS VI 24 NOV 2021 REV 4.pdf PDF
Section J Attachment 1 Performance Work Statement (PWS) 23 Nov 2021 REV 1.pdf PDF
Section J Attachment 5 Pricing Matrix dated 23 Nov 2021 REV 1 (Locked Formulas).xlsx XLSX spreadsheet
Section J Attachment 10 Instructions to Offerors 23 Nov 21 REV 3.pdf PDF
INDUSTRY QUESTIONS REGARDING FA863022R4000 PROS VI 23 NOV 2021 REV 3.pdf PDF
Section J Attachment 9 SECTION H PROS VI OBJECTIVE PERFORMANCE INCENTIVE OPI 23 NOV 2021 REV 1.pdf PDF
AMENDMENT TO RFP REGARDING FA8630-22-R-4000 PROS VI 23 NOV 2021 Rev 2.pdf PDF
INDUSTRY QUESTIONS REGARDING FA863022R4000 PROS VI 2 NOV 2021 REV 2.pdf PDF
INDUSTRY QUESTIONS REGARDING FA863022R4000 PROS VI 29 OCT 2021 REV 1.pdf PDF
Section J Attachment 10 Instructions to Offerors 29 Oct 21 REV 2.pdf PDF
AMENDMENT TO RFP REGARDING FA8630-22-R-4000 PROS VI 29 OCT 2021 Rev 1.pdf PDF
AMENDMENT TO RFP REGARDING FA8630-22-R-4000 PROS VI 27 Oct 21.pdf PDF
Section J Attachment 10 Instructions to Offerors 27 Oct 21 REV 1.pdf PDF
INDUSTRY QUESTIONS REGARDING FA863022R4000 PROS VI 26 OCT 2021.pdf PDF
Section J Attachment 8 FAR 52.204-24 Representation Regarding Certain Telecommunications and Video Surveillance Services or Equipment (Aug 202.pdf PDF
Solicitation FA863022R4000 25 October 2021.pdf PDF
Sect L Attachment 4 Past Performance Information Tool Instructions and Character Limit.pdf PDF
Section J Attachment 1 Performance Work Statement PWS 25 Oct 21.pdf PDF
Section J Attachment 11 Evaluation Criteria 21 Oct 21.pdf PDF
Section J Attachment 10 Instructions to Offerors 21 Oct 21.pdf PDF
Section J Attachment 7 - General and Wage Rate Schedules 13 Oct 21.pdf PDF
Section J Attachment 9 SECTION H PROS VI OBJECTIVE PERFORMANCE INCENTIVE OPI 21 OCT 2021.pdf PDF
ppi_tool.zip ZIP file
Section J Attachment 6 Specifications and Standards 25 Oct 21.pdf PDF
Section L Attachment 5 Past Performance Questionnaire.pdf PDF
Section J EXHIBIT A DD FORM 1423 CONTRACT DATA REQUIREMENTS LIST CDRL.pdf PDF
Section J Attachment 5 Pricing Matrix dated 21 OCT 2021 Locked Formulas.xlsx XLSX spreadsheet
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FA8630-22-R-4000

Section J, Attachment 4, PROS SDR Processes

15 March 2021

PROS Supply Discrepancy Report (SDR) Processes

In accordance with PWS Paragraph 4.3 and Appendix A, the processes outlined in this document shall be used for all PROS Supply Discrepancy Reports (SDR). ILCO timeframes are provided for illustrative purposes only. All timeframes are calendar days.

Table of Contents Process 1 – Original SDR

Process 2 – Request for Reconsideration

Process 3 – Contested SDR

Process 4 – Request for Additional Information

Process 5 – Exhibit Return Request

15 March 2021

Process 1 – Original SDR

Step Activity Max Calendar

Days

Action

1 ILCO

(AFSAC

SDR Office)

5 Review SDR

Release record to PROS contractor, updating SDR-A to status 20 – Awaiting Action Agency Response, or close w/104 or denial w/o sending out

2 Contractor

(PROS

Prime Contractor)

60 Review SDR and coordinate with vendor as applicable

If SDR is for information only (H1), such as extended dollar value is $200.00 or less, contractor shall reply with action activity response code 144 “Recorded for information and trend analysis”

If contractor requires additional information from customer to process SDR, refer to Process 4

If contractor requires exhibit return for evaluation, refer to Process 5

If necessary, request extension of Estimated Completion Date (ECD); there shall be no more than two extensions of ECD and total of extension(s) shall not exceed 180 days and extension requests must have valid justification ; Valid justification consists of documentary evidence from vendor of action(s) in process to resolve SDR

Input interim response in WebSDR extending ECD; response shall provide progress and SDR will be changed to 21 status

Provide detailed validity recommendation with supporting documentation and Proof of Delivery (POD) to WebSDR input pending POD receipt

Upload all supporting documentation and POD (as applicable) in WebSDR

3 ILCO 5 Review contractor’s reply and

Release SDR to FMS customer or

Reject SDR response if missing attachments identified in response or

Coordinate, via email, with contractor if clarification of response is required

Or reject response (23) for clarification

If interim response, change status to reflect (21)

4 Contractor 5 If rejected due to missing attachments, input documentation in WebSDR

If email is received from ILCO for clarification, provide response

For rejected response (23) in step 4, coordinate and input revised response in WebSDR

5 ILCO

Review contractor’s reply and

Release SDR to FMS customer or reject if reply is lacking/insufficient

15 March 2021

Process 2 – Request for Reconsideration If original SDR claim is determined not valid, customer may request reconsideration. A request for reconsideration containing additional discrepancies NOT reported in original SDR may be determined not valid unless the initial failure prevented customer from discovering additional discrepancy, e.g. item failed on step 1 of test in original SDR and upon return to customer it failed on step 3.

Customer must request reconsideration within 45 days of original SDR response release date as indicated in SDR-A, unless exhibit was returned during original SDR. If exhibit was returned, customer is allowed 90 days to request reconsideration.

Step Activity Max Calendar

Days

Action

1 Customer 45 or 90 Request Reconsideration of SDR, including added info required required for 2 ILCO 5 Update SDR to status 20 “Awaiting Action Agency Response” and route to contractor or deny if no added info furnished

3 Contractor 60 Review SDR and coordinate with vendor as applicable

Recommend SDR not valid if customer claims additional discrepancies not reported in original SDR

If contractor requires additional information from customer to process SDR, refer to Process 4

If contractor requires exhibit return for evaluation, refer to Process 5

If necessary, request extension of Estimated Completion Date (ECD); there shall be no more than two extensions of ECD and total of extension(s) shall not exceed 180 days and all extension request must have valid justification ; valid justification consists of documentary evidence from vendor of action(s) in process to resolve

SDR

Input interim response in WebSDR extending ECD; response shall provide progress status

Upload all supporting documentation and POD (as applicable) in WebSDR

Input reply in WebSDR

4 ILCO 5 Review contractor’s reply and

Release SDR to FMS customer or

Place SDR in Interim status (21) if awaiting POD and update suspense or

Reject reply (23) if missing or incorrect attachments identified in response or

Coordinate, via email, if response clarification required

If interim response, status will be updated to reflect (21) o

Reject response (23), if PMO does not clarify within 5 days

5 Contractor 5 If rejected due to missing attachments, input documentation in SDR-A

If email is received from ILCO for clarification, provide response

For rejected response (23) in step 5, coordinate and input revised response in SDR-A

6 ILCO

Review contractor’s reply and

Release SDR to FMS customer or reject if reply is lacking/insufficient

15 March 2021

Process 3 – Contested SDR If Reconsideration SDR is determined invalid, customer may contest decision with additional supporting documentation. Additional discrepancies NOT reported in original or reconsideration SDRs will be determined invalid unless initial failure prevented customer from discovering additional discrepancy, e.g.

item failed on step 1 of test in original SDR and upon return to customer it failed on step 3.

Customer must request contest within 45 days of reconsideration SDR response release date as indicated in SDR-A, unless exhibit was returned during reconsideration SDR. If exhibit was returned, customer is allowed 90 days to request contest.

Step Activity Max Calendar

Days

Action

1 Customer 45 or 90 Submit Contested SDR with additional supporting information

2 ILCO 20 Upon receipt, ILCO will review the contested SDR submission and supporting documentation (status code 14 – “Rejected SDR Submission

– Requires ILCO Review”)

Change SDR to status 26 – “ILCO Intervention”

Validate and prepare the contested package to include cover letter for PMO and AFLCMC/WFK, to include statement of events and copies of any supporting documentation

If additional, substantive information provided by customer or an event has occurred requiring another PMO review, forward contested SDR package to PMO

Change SDR status code to 15 – “Awaiting PROS PMO Assessment (Contested)”

3 PROS

PMO (As Required)

50 Review and generate PMO assessment of SDR claim

As part of PMO assessment, contractor may be required to review any additional information provided in contested package to determine if additional information impacts previous decision

Attach PMO assessment to contested SDR package and return to ILCO

If, during PMO assessment, vendor reverses previous denial and proposes resolution to SDR, PMO will coordinate contractor’s response via email with ILCO; If additional information or exhibit return is required, the process reverts back to Process 2; Request info or exhibit return per Process 4 or 5 as applicable

15 March 2021

Step Activity Max Calendar

Days

Action

4 ILCO As required

Coordinate with AFSAC management (Legal, SAF/IA & DSCA as applicable); If no contractor/USG liability:

Determine location of assets and direct return to customer if required

Obtain evidence of material return and attach to final reply

Input reply closing SDR in SDR-A (status code CD – “Credit Denied”) and send final reply to customer

If USG liable:

Determine location of assets and direct return to customer if required

Obtain evidence of material return and attach to final reply

Input reply closing SDR (status code CA – “Credit Approved”) and send final reply to customer

Process reimbursement via admin funds

If Contractor liable:

Forward package to AFSAC/WFK for resolution

Change Status code to 54 – “Awaiting AFLCMC/WFK Action on Legal or MILDEP/DSCA Approval.”

5 AFSAC/

WFK

30 If AFLCMC/WFK accepts SAF/IA and DSCA final determination of contractor liability, take appropriate action by issuing demand letter to PROS contractor with copies to ILCO, Legal, and PMO

If AFLCMC/WFK disagrees with SAF/IA and DSCA final determination and justifies contractor non-validity recommendation:

Coordinate response with necessary parties

Generate official correspondence for SAF/IA and DSCA review that justify contractor’s recommendation

Forward official correspondence to ILCO

6 Contractor 30 Respond to demand letter

Provide credit by inputting reply with action activity response code 101 – “Credit Approved” and process credit invoice, if applicable, or

Provide alternate method of resolution

7 AFSAC/

WFK &

PMO

5 Notify ILCO of final contract resolution

15 March 2021

Process 4 – Request for Additional Information

Step Activity Max Calendar

Days

Action

1 Contractor 10 Input reply in WebSDR (Reply code 104 – “Additional Clarification Required from Customer. See Remarks”)

2 ILCO 5 Forward SDR reply requesting additional information to customer and update SDR status to 99 - “Awaiting Customer Response”

3 Customer 45 Provide additional information requested

4 ILCO 5 If received within 45 days, SDR-A will automatically forward updated SDR to contractor, updating SDR to status 20 – “Awaiting Action Agency Response”

Process reverts to Process 1 or 2 as applicable

If response from customer not received by day 46, SDR-A will automatically close SDR and provide email notification to customer, PMO and contractor

Process 5 – Exhibit Return Request Note 1: Customer is required to return exhibit to USG custody within 180 days of notification as indicated in SDR-A. If vendor requires exhibit receipt at its facility (versus USG in-country turn-in point) within specified warranty timeframe and that timeframe is less than the required 180 days, contractor shall notify customer of reduced exhibit return time, with explanation why return time is reduced.

Note 2: When requesting exhibit, contractor shall include POC name and phone number at the exhibit destination in the exhibit request per U.S. Customs requirement.

Step Activity Max Calendar

Days

Action

1 Contractor 10 Provide Not To Exceed (NTE) cost if evaluation fee will be charged for TTI should SDR be denied

Notify customer of reduced exhibit return time if applicable w/explanation

Input exhibit return request in WebSDR (Reply Code 108 – “Forward Material to Address Shown for Inspection/Exhibit Analysis)

2 ILCO 5 Generate DD 1348 for customer to return discrepant material

Update SDR status to 99 – “Pending Exhibit Return”

Monitor SDR until material physically returned to final destination provided by contractor

3 Customer 180 Properly package SDR exhibit for shipment

Return SDR exhibit as directed to final destination provided by contractor (USG allows an additional 30 days for customer to provide notification of shipment for total of 210 days, except as indicated in Note 1 above. Customer will receive follow-up reminder at 60 and 120 days and notice of closure at 210 days)

Notify ILCO of material return; Failure to notify may result in closure of

SDR

4 ILCO 5 If customer provides notification of exhibit turn-in to USG custody, ILCO will attach to record, await receipt confirmation by contractor

Upon confirmation of exhibit receipt at final destination, ILCO will update SDR status to 20

– “Awaiting Action Agency Response” w/contractor’s Estimated Completion Date (ECD) of TTI

15 March 2021

Step Activity Max Calendar

Days

Action

5 Contractor 60 If exhibit not received as required, contractor inputs denial in WebSDR;

SDR may revert back to Process 1 or 2

SDR reverts back to Process 1 or 2 as applicable