SCPS_Sprinkler_System_.pdf
PDF 183 KB Posted
- Attached to
- Fire Sprinkler Inspections and Repairs
- Solicitation number
- 25260015B-TL
- Issued by
- Florida
About this file
This is a Sprinkler System Inventory document for Seminole County Public Schools (SCPS) in Florida, detailing fire sprinkler systems across multiple school facilities organized into three zones (A, B, and C). The document provides comprehensive specifications for fire sprinkler infrastructure at 65+ facilities, including elementary schools, middle schools, and high schools. For each facility, the inventory identifies building and room numbers containing risers, fire alarm control panels (FACP), inspector test locations, sprinkler head counts, and site-specific details such as key numbers for pressure isolation valves (PIV), backflow preventers (BFP), fire department connections (FDC), and fire hydrant quantities. The document indicates that most facilities have wet sprinkler systems, with some featuring dry systems or pre-action systems. Notable facilities include Seminole High School with 17 buildings and multiple systems, Lake Brantley High School, Oviedo High School, and various elementary and middle schools with system counts ranging from single buildings to multiple structures per campus.
The inventory serves as a reference document for the Fire Sprinkler Inspections and Repairs contract opportunity with Seminole County Public Schools, which seeks qualified contractors under Florida Statute 633 to provide inspection, testing, maintenance, and repair services. The document includes detailed equipment specifications such as PIV key numbers (ranging from 356 to 3217), backflow preventer locations with specific key identifications, and auxiliary drain locations. Additionally, the inventory notes special systems including nitrogen dry systems at Indian Trails Middle School, pre-action systems at ESC and Woodlands Elementary, and Inergen suppression systems at Sanford Middle School. Contact information for vendors is provided, with email addresses listed for service providers. The systematic organization by zone and facility allows for efficient contractor assignment and maintenance scheduling across the district's fire protection infrastructure.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sprinkler System Zone A
Facility Bldg#/Rm# Riser(s) Bldg#/Rm#
(FACP)
Bldg#/Rm# (Inspector test)
Additional Notes (PIV key #'s, bldg. or stairwell locations, etc.)
Site Map
Bldg. #'s Sprinkled
Sprinkler Head count
Carillon Elem.
01-119, 02-110, 03-111, 04-116, 05-106, 06-116, 07-113, 09-108 (8 Wet system Risers)
01-100 and 07-104A
01-127C(wall), 02-101I, 03-117, 04-100(ceiling), 05-113, 06-114C, 07-104A, 09-108
Bldgs. 1-7 and 9 only (all single story blds.), PIV key# 3217 for all locks; all control valves key# 863; 6 FDC's, 6
PIV's, 1 BFP, 4 hydrants
Yes 1-7, 9
Bldg. 1: 61, Bldg. 2: 91, Bldg. 3: 111, Bldg. 4: 137, Bldg. 5: 106, Bldg. 6: 146, Bldg. 7: 55, Bldg. 9: 276
Casselberry Elementary 1075 Crystal Bowl Circle Casselbery, 32707
01-037A
FACP 01-
038, FAAP
01-001 01-037A
01/12/22, the site is under construction. Bldg. 1 (2 story), PIV's 1, FDC's 1, backflows 3, 2 hydrants.
YES Bldg 1 ?
Chiles M.S.
01-035, 02-014, 02-218, 03-003, 03-203, 04-003, 04-203, 05-020 (5 Wet system Risers)
01-018J
01-034, 02-014, 02-218, 03-003, 03-203, 04-003, 04-203, 05-018
Bldgs. 1-5 only, Bldgs. 2-4 are 2-stories, key #3217 PIV's bldgs. 1, 2, 3, and 4, key #356 for 2 BFP's and bldg. 5 PIV, 3 hydrants
Yes 1-5
Bldg. 1: 277, Bldg. 2: 359, Bldg. 3: 341, Bldg. 4: 361, Bldg. 5: 349
Eastbrook Elem.
01-047, 01-022B, 02-013, 03-013
(4 Wet system Risers)
01-001, and 03-015
(CER room) within Media Center 03-006
01-007, 02-002A(ceiling), 03-013, 03-213, 04-003E(ceiling)
Bldgs. 1-5 only, bldgs. 1, 2, 4, and 5 are one story, and building 3 is 2-story, 4 PIV's (key#'s 356 and 3217), 2 BFP's (key# 412), 3 hydrants, and 4 FDC's
Yes 1-5
Bldg. 1: 419, Bldg. 2: 82, Bldg. 3: 209, Bldg. 4: 419, Bldg. 5: 71
Evans Elem.
01-136A(sw) and
01-259A(sw) (1 Wet system Riser)
01-102M and 01-141
01-136A(sw) and 01-259A(sw)
Bldg. 1 only (2-story), key# 3217 for CV's on Riser; 2 hydrants,1 FDC, 2 BFP's, no PIV's on campus
Yes 1 Bldg. 1: 1012
Facilities Maintenance 820 East S.R.
434 Winter Springs, FL
32708
N/A 02-002 N/A Hydrants & Backflow YES N/A N/A
Hagerty H.S.
01-127, 02-107, 03-109, 04-108, 05-118B, 06-123, 07-110, 08-100G, 09-111, 09- 123 (10 Risers)
01-123, 02-121, 03-107, 04-117, 06-124, 07-109, 08-202A, 09-120L
01-105(wall), 02-115A, 03-125A, 04-109, 05-115, 06-123, 07-110, 08-100G, 08-101F (Aux. drain), 09- 111, 09-123
Bldgs. 1-9 only; bldgs. 1, 4, 5, 8, and 9 are one story, bldgs.
2, 3, 6, and 7 are 2-stories; all PIV's key# 863; 10 FDC's, 10
PIV's, 1 BFP, 9 hydrants
Yes 1-9
Bldg. 1: 81, Bldg. 2: 396, Bldg. 3: 442, Bldg. 4: 235, Bldg. 5: 176, Bldg. 6: 439, Bldg. 7: 406, Bldg. 8: 258, Bldg. 9: 437
Bldg#/Rm# (Inspector test)
Additional Notes (PIV key #'s, bldg. or stairwell locations, etc.)
Site Map
Bldg. #'s Sprinkled
Sprinkler Head count
Indian Trails M.S.
03-112, 04-107, 05-103, 06-122(sw), 06-222(sw), 07-124(sw), 07-224(sw)
(5 Wet system Risers)
01-123
03-102A, 03-112, 04-101A (wet), 04-104, 04-107 (dry), 05-101B, 05-103, 06- 122(sw), 06-222(sw), 07-124(sw), 07-224(sw)
Bldgs. 1, 2, 3, 4, 5, 6, and 7;
bldgs. 1, 2, 3, 4, and 5 are one story; bldgs. 6 and 7 are 2-stories; 5 PIV's key# 412, 4 hydrants, 3 FDC's, and 2
BFP's key# 412; key SKD-5 for 04-101A IT room; 2 wall OSY's key# 412; Nitrogen dry system 04-107, Aux. drain 01-128B, 04-105, and 05-105; test nitrogen system from Riser 04- 107 with test and flow switch;
IT's for nitrogen dry system outside of 05-100 in fenced area and outside 02-100
Yes 1-7
Bldg. 1: 145, Bldg. 3: 91, Bldg. 4: 140, Bldg. 5: 143, Bldg. 6: 431, Bldg. 7: 439
JHMS
02-004, 08-122E, 09- 004 (3 Wet system
Risers)
05-001N, 05-007G, and 08-104
02-012A, 02-203, 08-113, 09-004, 09-204
Bldgs. 2 (2-story), 8 (one story), and 9 (2-story)only;
1 PIV (key# 412), 2 hydrants (hydrant by bldg. 8 sets off fire alarm), 2 BFP's(key# 412), and 2 FDC's, 02-207A
Aux.drain and CV
Yes 2, 8, and 9 Bldg. 2: 219, Bldg. 8: 154, Bldg. 9: 191
Keeth Elem.
01-039 (2 Wet systems for building 1 and 1 Dry system for kitchen of building 1)
01-016 01-039 Bldg. 1 (one story); No PIV's on campus, 1 FDC, 1 BFP
(key# 412), 2 hydrants Yes 1 Bldg. 1: 661
Lake Howell H.S.
01-100, 02-102, 03-119, 05-004
(4 Wet system Risers)
01-123 and 03-107
01-100, 02-102, 03-119, 05-009A(wall)
Bldgs. 1 (one story), 2 and 3 (both 2-stories), and 5 (stage and stage area, one story) only, 10 hydrants, 4 PIV's and 1 WPIV (key# 412), 5 FDC's, and 3 BFP's (key# 412)
Yes 1, 2, 3, 5
Bldg. 1: 331, Bldg. 2: 290, Bldg. 3: 278, Bldg. 5: 90
Lawton Elem. 02-001F 01-010 02-102(wall)
Bldg. 2 only (one story), BFP key# 464, 1 FDC on BFP, no
PIV's on campus, 2 BFP's and 1 hydrant
Yes 2 Bldg. 2: 232
Layer Elem. 01-143 01-102M and 01-141
01-136(sw,ceiling), 01-106(sw,ceiling), 01-256B(sw,ceiling)
Bldg. 1 only (one story); no PIV's on campus, 3 hydrants, 1 FDC, and 1 BFP(on Riser), Aux. drain 01-120(ceiling)
Yes 1 Bldg. 1: 967
Lyman H.S.
03-032A, 04-024, 04-209, 06-002, 07-102M, 08-023, 09-
01-001, 01-045, 02-017, 03-, 04-, 06-037, 07-115, 08- 019, 09-015
02-036, 03-013A, 04-024, 04-209, 06-002, 07-102F, 08-002D, 09-018
Bldgs. 2, 3, 6, 8, and 9 (one story) and bldgs. 4 and 7 (two story) only; 5 BFP's key# 412;
2 BFP's on road no key #, Bldg. 9 PIV on campus, Bldg 9 wet & dry system, 4 hydrants, 5 FDC's, Aux. drain 02-036, quarterly inspections
Yes 2, 3, 4, 6, 7, 8, and
Bldg. 2: 290, Bldg. 3: 350, Bldg. 4: 367, Bldg. 6: 241, Bldg. 7: 57, Bldg. 8: 341, Bldg. 9 ?
Bldg#/Rm# (Inspector test)
Additional Notes (PIV key #'s, bldg. or stairwell locations, etc.)
Site Map
Bldg. #'s Sprinkled
Sprinkler Head count
Oviedo H.S.
01-050, 02-023, 04-013A, 05-027(sw), 06-006A, 07-014, 08-015B, 09-006, 10-008, 11-004, 12-025, and 13-018
01-042, 02-009, 04-007, 05-002A, 07-007A, 08-040, 09-003K, 11-009, 13-003
01-050, 02-018, 04-006F, 05-005E, 06-006A, 07-002A, 08-015B, 09-006, 10-008, 11-007(wall), 12-025, 13-008A
Bldgs. 1, 2, 4, 5(key#464), 6, 7, 8, 9, 10, 11, 12, and 13;
bldgs. 5 and 8 are 2-story, rest of bldgs. are one story; 8 hydrants; Aux. drains 02-019, 02-003A, 04-008
Yes
1, 2, 4, 5, 6, 7, 8, 9, 10, 11, 12, and
Bldg. 1: 285, Bldg. 2: 250, Bldg. 4: 200, Bldg. 5: 439, Bldg. 6: 39, Bldg. 7: 211, Bldg. 8: 744, Bldg. 9: 190, Bldg. 10: 76, Bldg. 11: 116, Bldg. 12: 176, Bldg. 13: 306
Partin Elem. 05-007D 01-014 05-007C
Bldg. 5 (one story) stage area only, key# 863 for Riser CV, PIV, and BFP; 3 BFP, 1 FDC, 1 PIV, and 4 hydrants
Yes 5 Bldg. 5: 15
Pine Crest Elementary 01-028F, 02-001 01-001 01-028F, 02-001
Building 1 (2 story), Bldg. 2 Chiller. 3 hydrants, 3 backflows, 2 PIV's, 2 FDC's Yes 1 & 2 ?
Rainbow Elem. 04-001F 01-001 04-001F
Stage area only of building 4 (one story); Riser CV key# 863, 4 FDC's, 4 hydrants, 1 BFP, 15 FDV's, no PIV's on campus; all hose connections on outside of buildings are dry, must test using fire hydrants
Yes 4 Bldg. 4: 11
South Sem.
M.S.
01-018, 02-007, 03-041B, 03-241, 03-337, 04-002, 05-001, 07-010, 08-007
02-008
01-018, 02-007, 03-041B, 03-241, 03-337, 04-002, 05-001, 07-007, 08-007
Bldgs. 1, 2, 3, 4, 5, 7 and 8 only; bldg. 3 is 3-stories, rest of campus is one story; 7 PIV's key# 412, 8 hydrants, 7 FDC's, 2 BFP's, 05-003 (AD), 05-
006(AD), 07-015 (AD), 04-
002(AD),
Yes 1-5, 7, and 8
Bldg. 1: 39, Bldg. 2: 73, Bldg. 3: 950, Bldg. 4: 72, Bldg. 5: 102, Bldg. 7: 126, Bldg. 8: 165
Stenstrom Elem. 02-004B, 07-015 01-002, 07-
001A 02-004A, 07-015
Bldg. 2 stage area only (one story), Bldg. 7 two story, key#
412 for 2 BFP and 2 PIV, 4 hydrants
Yes 2 and 7 Bldg. 2: 24, Bldg.7: 207
Tech. Park 01-139 01-139 01-139
Bldg. 1 only (one story), no PIV's on property, 1 FDC, 2 hydrants, quarterly inspections
Yes 1 Bldg. 1: 213
Tuskawilla M.S.
01-022, 02-008, 03-008, 04-007, 05-031, 06-009 01-007
01-022, 02-008, 03-008, 04-007, 05-031, 05-206, 05-306, 06-009
Buildings 1-6; bldg. 5 is 3-stories and bldgs. 1-4, and 6 are one story; PIV and BFP key# 412; 6 PIV's, 1 FDC at BFP, Aux. drains in 06-003 and 05-031, and 5 hydrants
Yes 1-6
Bldg. 1: 79, Bldg. 2: 78, Bldg. 3: 123, Bldg. 4: 98, Bldg. 5: 1st fl- 327, 2nd fl-335, 3rd fl-338, Bldg.
6: 177
Bldg#/Rm# (Inspector test)
Additional Notes (PIV key #'s, bldg. or stairwell locations, etc.)
Site Map
Bldg. #'s Sprinkled
Sprinkler Head count
25th. PL.
Warehouse
601 east 25th Place
Sanford, FL.
32771
N/A YES N/A Hydrants only YES N/A N/A
Walker Elem. 01-143 01-102M and 01-141
01-136(sw), 01-106(sw), 01-206(sw)
Building 1 only (one story), key# 3217 for BFP; no PIV's on campus, 1 FDC, 2 hydrants Yes 1 Bldg. 1: 933
Winter Springs H.S.
02-105, 02-128, 03-106, 04 back NE(sw), 05 back NE(sw), 07 back NE(sw), 08-110, 09-138
01-110 and 18-
02-100, 02-130, 03-115, 04-113, 05-117, 07-113, 08-121, 09-146
Bldgs. 1-9 only; bldgs. 1, 2, 3, 8, and 9 are one story, bldg. 4-
7 are 2-stories; key# 464 for some WPIV's and breakaway for some WPIV's, access panels, and BFP; 8 WPIV's, 8
FDC's, 7 hydrants, 1 BFP
Yes 1-9
Bldg. 1: 76, bldg. 2: 328, bldg. 3: 92, Bldg. 4: 218, Bldg. 5: 205, bldg. 6: 235, Bldg. 7: 230, bldg. 8: 140, Bldg. 9: 265
Total: Total Hydrants:
sw=stairwell
Flow tamper = shows on fire alarm control panel only as Supervisory Flow IT = sets off the fire alarm and shows as trouble on fire alarm control panel Flow main drain = shows on fire alarm control panel only as Supervisory Flow PIV (if tampered) = shows on fire alarm control panel only as Supervisory Fire pump comes in as Supervisory mailto:Cffp@aol.com
Sprinkler System Zone B
Facility Bldg#/Rm# Riser(s) Bldg#/Rm#
(FACP)
Bldg#/Rm#
(Inspector test)
Additional Notes (PIV key #'s, bldg. or stairwell locations, etc.)
Site Map
Bldg. #'s Sprinkled
Total Fire Sprinkler
Heads
Altamonte Elem., 525 Pineview
Street, Altamonte, FL 32701, (407)-
746-2950
01-002, 05-020(sw), 05-217(sw) 01-008
01-002, 05- 020(sw), 05-
217(sw)
Bldgs. 1-4 are one story and 5 is 2-stories; 2 PIV's, PIV key lock# 412, 2 hydrants
Yes 1, 2, 3, 5 909
Bear Lake Elem., 3399 Gleaves
Court, Apopka, FL 32703, (407)-746-
13-108 01-105 13-125 Bldg. 13 (one story) only;
PIV key#464, 4 hydrants Yes 13 272
ESC (Seminole Administrative Offices), 400 E.
Lake Mary Blvd., Sanford, FL
32773, (407)-320-
01-103, 01-203, 01- 303, 01-403, 02-001, 01-318 (dry Pre-Act) serves IS room
01-309
01-120 01-103, 01-203, 01-303, 01-403
Bldg. 1 (4-stories) only; bldg.
2, 02-001, has fire pump, PIV key# 464; bldg. 1 also has Pre-Act system in 01-
318 serves IS room 01-309, 2 hydrants, quarterly inspections
Yes 1 909
English Estates Elem., 299 Oxford Road, Fern Park, FL 32730, (407)-
746-2850
01-025B, 06-100FI 01-049 01-057, 06-
108A bldgs. 1 and 6 only (both are one story), 1 PIV key lock#
412, 2 hydrants Yes 1 and 6 565
Heathrow Elem., 5715 Markham
Woods Road, Lake Mary, FL 32746, (407)-320-6850
05-007D 01-014 05-007C Bldg. 5 (one story) stage and side rooms only, key lock#
412 on PIV, 3 hydrants Yes 5 20
Hamilton Elem.
1501 East 8th St., Sanford FL. 32771
01-093 01-031F 01-093 3 hydrants, 1 FDC, 1 PIV YES 1 800
Highlands Elem., 1600 Shepard Road, Winter Springs, FL
32708, (407)-746-
01-117 and 01-144 01-127A 01-122 and 01-
Bldg. 1 (2-stories) only, PIV key# 464, 3 hydrants Yes 1 1002
Lake Brantley H.S., 991 Sand
Lake Road, Altamonte
Springs, FL 32714, (407)-746-
03-005, 05-005A, 06-108, 07-109, 08-
109, 09-118 03-010C
03-005, 05- 005A, 06-108, 07-109, 08-
109, 09-105
Bldgs. 3, 5, 6, 7, 8, and 9 only; 5 PIV's key# 412, 4 hydrants (2 along road are City's, 1 by fence City's?)
Yes 3, 5, 6, 7, 8, and 9 400
Lake Brantley South 1100 Sand lake Altamonte
Springs, FL. 32714
N/A Yes N/A Hydrants and backflow only YES N/A N/A
Longwood Elementary 840
Orange Ave.
Longwood, FL.
32750
N/A YES N/A Hydrants only YES N/A N/A
Millennium Middle 2330 East S.R. 46
Sanford, FL. 32771
01-017, 02-013, 03- 013, Satirwell 1st.
floor 04-035, 2nd.
Floor 04-035, 3rd.
Floor 05-025
01-002
FAAP, 01-
203 FACP,
02-010A
FACP, 02-
020 FACP,
03-112A
FACP, 04-
004A
FACP, 05-
008 FACP
01-017, 02-013, 03-013, 04-035 stairwell 1st.
Floor, 04-035 second floor, 04- 035 third floor, 05-025
PIV's Bldg. 1, 2, 3, 4, 5. Fire hose connection stairwells 04-010, 04-035, 04-001.
Hose connection flow/tamper 04-022E. 8 hydrants.
YES 1 thru 5 ?
Milwee M.S., 1341 S. Ronald Reagan Blvd., Longwood, FL 32750, (407)-
746-3850
02-009A, 04-020 03-002 02-010 (Mech.
rm.), 04-020 (mech. rm.)
Bldg. 2 (one story) stage area only, Bldg 4 Gym, 2 PIV's, 2 FCD's key lock#
412, 4 hydrants
Yes 2 & 4 2:22, 4:?
Red Bug Elem., 4000 Red Bug
Road, Casselberry, FL 32707, (407)-746-
01-024, 02-130, 03- 118, 04-017(sw landing)
01-001, 01-031, 01-039, 02-102, 03-106, 04-015(CER),
04-204(wall)
Bldgs. 1-3 are one story and bldg. 4 is 2-stories; PIV key# 0464, 3 hydrants, 3 FDC's
Yes 1-4
Rinehart Annex, 239 Rinehart
Road, Lake Mary, FL 32746, (407)-
01-026 01-001A 01-010 Bldg. 1 (one story) only, no PIV's on property, 1 hydrant Yes 1 94
Rock Lake M.S., 250 Slade Drive, Longwood, FL
32750, (407)-746-
01-912 (4 risers) 01-917 01-201, 01-202, 01-404, 01-421, 01-912
Bldg. 1 (one story) only, no PIV's on campus; 1 FDC, 3 hydrants Yes 1
1st floor:
1176, 2nd floor:
Teague M.S., 1350 McNeil Road, Altamonte Springs, FL
32714, (407)-320-
04-107, 06-122, 07- 122 01-100
04-101A, 06-122(sw), 06-222(sw), 07-122(sw), 07-224(sw)
Bldg. 4 (one story) stage area and bldgs. 6 and 7 (2-stories); 3 PIV's key# 412, 6 hydrants
Yes 4, 6, and 7 804
Transportation building 2 at "Tire Storage" garage area 01-006 Bldg. 2
(garage door 2)
Bldg. 2 only (one story), 1 FDC at "Tire Storage" garage area, 4 hydrants, 1 PIV combo 9401; all BFP's key #464
Yes 2 Bldg. 2:
Winter Springs Elem.
01-002, 02-016(sw), 02-216A(sw), 04-002
01-008 and 02-015
02-016(sw), 02-216A(sw), 06-007A, 07-
006E
Bldgs. 1, 2, 3, 5, 6, and 7 only; bldgs. 1, 3-7 are one story, and bldg. 2 is 2-stories; key# 412 for PIV's;
3 hydrants, 3 FDC's, 3 PIV's, 2 BFP's
Yes 1-3, 5-7
Total: 847, did not do by bldg.
number
Woodlands Elem., 1420 E.E.
Williamson Road, Longwood, FL
32750, (407)-746-
02-125, 02-218;
Pre-Act 02-105 02-107 02-125(ceiling), 02-219
Bldg. 1 and 3 (one story) and bldg. 2 (2 -story) only; 02-
125, 02-218; Pre-Act (dry) system covers 02-107, 02- 101, and 02-211; 1 BFP,1
FDC, 4 hydrants, no PIV's on campus
Yes 1-3 651
Total: Total fire hydrants:
sw=stairwell
Flow tamper = shows on fire alarm control panel only as Supervisory Flow IT = sets off the fire alarm and shows as trouble on fire alarm control panel
Flow main drain = shows on fire alarm control panel only as Supervisory
LBHS hydrants not marked, 2-3 are City's Lake Brantley South hydrants not marked mailto:farrellfireprotection@yahoo.com
Sprinkler System Zone C
Facility Bldg#/Rm# Riser(s) Bldg#/Rm#
(FACP)
Bldg#/Rm#
(Inspector test)
Additional Notes (PIV key #'s, bldg. or stairwell locations, etc.)
Site Map
Bldg. #'s Sprinkled
Total Fire Sprinkler Heads
Bentley Elem. 01-136(sw), 03-108 01-102M 01-114, 01-128, 03-108
Bldgs. 1 (2-story) and 3 (one story)only, key# 863, 3 hydrants Yes 1 and 3 Bldg. 1:953, Bldg.
3:252
Crooms AOIT 01-122, 02-103A, 03-
01-101B, 03-
01-122, 02-103A, 03-025
Bldgs. 1 (2-story) Blgd 2 & 3 (one story) only, 3 hydrants, 2 PIV, 2 FDC, 2 BF's Yes 1,2 & 3 1-2: 524, Bldg 3: ?
Crystal Lake Elem. 01-140 01-124D
01-101i, 01-100R(sw), 01-214
Bldgs. 1 (2-story) only, 3 hydrants. BFP key#? Yes 1 919
Early Learning Center, "Old"
Hopper Center 01-114 01-105 01-101(ceiling)
Bldg. 1 only (one story), FDC and OSY on road, PIV key#
464, no fire hydrants Yes 1 155
Endeavor School
02-010, 03-011, 04- 016, 06-011
01-001, 08-001
01-017, 02-010, 03-011, 04-016, 06-011
4 fire hydrants, 5 FDC's, and 5 PIV's and 3 BFP's (all key
#0464) Yes 2-4, 6
Bldg. 2:87, Bldg.
3:52, Bldg. 4:80, Bldg.
6:61
Environmental Studies center 2985 Osprey
Trl. Longwood, FL. 32714
N/A YES N/A Steel underground storage tank 12,000 Gal. YES N/A N/A
Educational Support
Center Annex 02-128A, 03-104 01-, 02-128
02-128A, 03-104, 01-vault of old Rays of Hope
Bldgs. 1-3 (one story), Building has 1 system
(shares with Rays of Hope), no PIV's, 2 hydrants
Yes 1-3 2 systems: Print shop
Forest City Elem. 01-002B, 03-017 01-014 and
03-007L 01-002B, 01-043, 03-007D Bldg. 1 (one story) and 3 (2-story) only, 4 hydrants Yes 1 and 3 Bldg. 1:402, Bldg.
3:415
Geneva Elementary 275 First St.
Geneva, FL.
32732
N/A YES N/A Well Only. Hydrants & backflow. YES N/A N/A
Goldsboro Elem.
06-111, 07-107, 09- 103 06-104F 06-104H, 07-107, 09-105
Bldgs. 6 and 9 (one story), and 7 (2-story) only, PIV key
# 464, BFP key # 464, 2 hydrants, 3 FDC's
Yes 6, 7 and 9 3 systems: Bldg.
6:101, Bldg. 7:303, Bldg. 9:102
Greenwood lakes Middle
601 Lake Park Dr. Lake Mary, FL. 32746
N/A YES N/A Hydrants only YES N/A N/A
Idyllwilde Elem. 02-001, 04-102(sw) 01-103 02-001, 04-
102(sw)
Bldgs. 1 and 2 (one story) and 4 (2-story) only, has fire jockey pump outside front of school, 2 hydrants; has 2 underground water storage tanks (2-30,000 gallon fiberglass tanks with suction pumps rated at 450 GPM flow each, connected by a 6 inch ductile iron pipe to well)
Yes 1, 2, and 4 ?
Journey's Academy 02-128A, 03-104 04-100 01-106, 02-128A, 04-100
Bldgs. 1, 2 and 4 only (all one story); 1 hydrant; shares with ESC Annex No 1, 2, and 4 230
Lake Mary Elem. 08-015 01-107, 08-007L
08-201A and 08-001E (sw) 1st floor
Bldg. 8 (2-story), 4 hydrants, 1PIV key # 10R41 Yes 8 Bldg. 8:278
Lake Mary H.S.
01-134, 01-217A, 01-244A, 01-251A, 03-115, 04-201C
01-226
01-101E, 01- 171C, 01-244A, 03-108A(AD),
03-119D, 04-
201C
Bldgs. 1 and 4 (2-story) and 3 (one story) only, OSY key# 356, 03-115 riser gate key# 3217; 7 hydrants, 2 FDC's, 2 BFP's, no PIV's on campus
Yes 1, 3, and 4 Bldg. 1:1729, Bldg.
3:350, Bldg. 4:186
Lake Orienta Elem.
01-051N, 02-019, 06-007A 02-006N
01-036B, 02-005(sw), 02-216, 04-002, Bldgs. 1-7; bldgs. 1, 3-7 are one story and building 2 is 2-stories; 2 PIV's, 3 FDC's, 2 hydrants
Yes 1-7 Bldg. 1:477, bldg.
2:334, Bldg. 4:157, Markham Woods M.S.
01-008A, 02-014, 02-218, 03-003, 03-203, 04-008, 04-207, 05-020, 06-014
01-018H
01-008A, 02-014, 02-218, 03-003, 03-203, 04-008, 04-207, 05-020, 06-014
Bldgs. 1-7 only; bldgs. 1, 3, 4, 5, 6, and 7 are one story, and bldg. 2 is 2-stories; 5 hydrants; BFP on each riser total of 6
Yes 1-6
9 systems: Bldg.
1:127, Bldg. 2:353, Bldg. 3:322, Bldg.
4:343, Bldg. 5:285, Bldg. 6:150
Midway Elem.
(New) 2638
Brisson Ave.
Sanford,Fl.
32771
01-140, 04-020 01-124D 01-101N, 01-126 (wall), 01-140
Bldg. 1 and Bldg. 4 (2-stories); 5 hydrants, 2 FDC, 2 BFP, 2 PIV
Yes 1 Bldg. 4: 207, Bldg.
1:935 3 systems
Midway Elementary (Old) 2251 Jitway Ave.
Sanford, 32771
N/A YES N/A N/A YES N/A N/A
Midway Safe Harbor 14-outside 14-101 14-101(back left corner) Bldg. 14 only (one story); 1 hydrant Yes 14 1 system, 101
Midway Transportation
01-013 Wet, 01-017 Antifreeze
01-001A, Annun. in 01-001
01-013 Wet, 01-017 Aux. drain, outside of 01-006
Dry
Bldg. 1; 4 fire hydrants, 1 FDC, 1 PIV, 2 BFP's 1 2 systems: 131
Seminole 9th Grade Center
40-127, 41-118, 42-101, 43-102, 44-025, 44-257, 44-160A, 44-254
44-102
40-104, 41-115, 42-112A, 43-102, 44-025, 44-257, 44-160A, 44-254
Bldgs. 40, 41, 42, 43, and 44 only; bldg. 41 stage standpipe only; bldg. 44 is 2-stories and bldgs. 40-43 are one story; no IT; 7 hydrants
Yes 40-44
Bldg. 40:59, Bldg.
41:260, Bldg. 42:108, bldg. 43:25, Bldg. 44:
4 systems, 844
ESC Annes 02-128A
01-, Electrical closet at front desk
Building 1 back vault
One story; included in ESC Annex inspection, fire alarm panel not tied into fire sprinkler system, 1 hydrant
Yes 1 208
Sabal Point Elem.
01-053, 02-019, 06- 005A 02-006N
01-014(AD),
02-016, 02-214, 04-004, 07-006E
Buildings 1-7; bldgs. 1, 3-7 are one story and bldg. 2 is 2-stories; 1 hydrant, 3 PIV's key# 10R41, 3 FDC's
Yes 1-7 Bldg. 1:430, Bldg.
2:255, Bldg. 6:114, Sanford M.S. 02-106, 10-034 02-127N 02-125, 10-030
Bldg. 2 (2-story bldg.) and bldg. 10 (stage area one story) only; Inergen system 02-127, 02-209 and 02-
227 (no longer exists, taken out), 3 hydrants
Yes 2 and 10 2 systems: Bldg.
2:566, Bldg. 10:20
Seminole H.S.
01-001B, 02-009, 03-028, 04-025, 04-218?, 05-016B, 05-218, 06-023, 07-117A, 08-006, 10-003B, 10-205, 11-016B, 12-021, 13-024C, 13-228, 14-017, 14-221, 16-001, 17-013
01-044, 02-002H, 03-035, 04-210C, 05-210C, 06-002F, 07-117A, 08-007, 10-210C, 11-007, 12-011, 13-019, 14-012, 16-001, 17-010
01-001B, 02-007, 03-028, 03-038, 04-025, 04-218
05-016B, 05-218, 06-002D, 07-112, 08-006, 10-016, 10-218, 11-001A, 12-025, 13-008C, 13-024C, 13-228, 14-016 (wall), 14-215, 16-001, 17-009
Bldgs. 1, 2, 3, 4, 5, 6, 7, 8, 10 (pressure gauge above ceiling 10-003B), 11, 12, 13, 14, 16, and 17 only; bldg.13 has 2 dry systems on outside balcony 1st and
2nd floors, bldgs. 1-3, 6-8, 11-12, 16-17 are all one story; bldg. 3 (several areas) has an Antifreeze system; bldgs. 4, 5, 10, 13, and 14 are 2-stories; 13 hydrants, 14 PIV's (bldgs. 3 and 10 key #10R41 and rest of bldgs. key #0356), 14 FDC's, BFP's on risers for bldgs. 12(2), 17(2), 11(2), 7(2), 6(2)
Yes
1, 2, 3, 4, 5, 6, 7, 8, 10, 11, 12, 13, 14, 16, and 17
Bldg. 1:157, Bldg.
2:170, Bldg. 3:113, Bldg. 4:172, Bldg.
5:345, Bldg. 6:187, Bldg. 7:92, Bldg.
8:181, Bldg. 10:391, Bldg. 11:96, Bldg.
12:270, Bldg. 13:369, Bldg. 16:29, Bldg.
17:204
Spring Lake Elem.
01-053, outside of 02-008, 03-012, 04-
01-013E 01-053, 02-012, 03-006, 04-002
Bldgs. 1-4 are all one story;
3 hydrants, 4 FDC's, 4 BFP's
(2 in front and 2 in back) Yes 1-4
Bldg. 1:344, Bldg.
2:80, Bldg. 3:68, Bldg.
4:73
Sterling Park Elem.
01-051M, 05-108C, 08-015
Ann. 01- 002, 01-
038, 05- 111A, 08-007L
01-051M, 04- 106A, 06- 102C, 08- 001E(sw)1st floor, 08-015 2nd floor
Bldg. 1-6 are one story and bldg. 8 is 2-stories; 4 BFP's key# 863, 6 PIV's silver keys, 4 hydrants, FDC's
Yes 1, 3, 4, 5, 6, and 8
Bldg. 1:474, Bldg.
5:120, Bldg.8:380, Wekiva Elementary 1450 East
Wekiva Trl.
Longwood, FL.
32779
01-005B, 07-008B, 08- 006B, 09-004
01-005B,07- 008B,08-
006, 09-004
FAAP 01-001,
FACP 01-030,
FACP 07-011,
FACP 08-005,
FACP 09-003
4 PIV's, 4 FDC's, 6 hydrants YES 1, 7, 8, 9 ?
Wicklow Elem. 01-136, 01-200 01-149K 01-136, 01-169
(flow test), 01-200 (drain only)
Building 1 (one story) only, 3 hydrants, BFP Key #0464 Yes 1 2 systems: 1005
Wilson Elem. 06-100F 02-105 06-102 (above ceiling)
Building 6 (one story) only, PIV key# 863, 5 hydrants Yes 6 218
Total: Total fire hydrants:
sw=stairwell
Flow tamper = shows on fire alarm control panel only as Supervisory Flow IT = sets off the fire alarm and shows as trouble on fire alarm control panel Flow main drain = shows on fire alarm control panel only as Supervisory