SCPS_Sprinkler_System_.pdf

PDF 183 KB Posted

Attached to
Fire Sprinkler Inspections and Repairs
Solicitation number
25260015B-TL
Issued by
Florida

About this file

This is a Sprinkler System Inventory document for Seminole County Public Schools (SCPS) in Florida, detailing fire sprinkler systems across multiple school facilities organized into three zones (A, B, and C). The document provides comprehensive specifications for fire sprinkler infrastructure at 65+ facilities, including elementary schools, middle schools, and high schools. For each facility, the inventory identifies building and room numbers containing risers, fire alarm control panels (FACP), inspector test locations, sprinkler head counts, and site-specific details such as key numbers for pressure isolation valves (PIV), backflow preventers (BFP), fire department connections (FDC), and fire hydrant quantities. The document indicates that most facilities have wet sprinkler systems, with some featuring dry systems or pre-action systems. Notable facilities include Seminole High School with 17 buildings and multiple systems, Lake Brantley High School, Oviedo High School, and various elementary and middle schools with system counts ranging from single buildings to multiple structures per campus.

The inventory serves as a reference document for the Fire Sprinkler Inspections and Repairs contract opportunity with Seminole County Public Schools, which seeks qualified contractors under Florida Statute 633 to provide inspection, testing, maintenance, and repair services. The document includes detailed equipment specifications such as PIV key numbers (ranging from 356 to 3217), backflow preventer locations with specific key identifications, and auxiliary drain locations. Additionally, the inventory notes special systems including nitrogen dry systems at Indian Trails Middle School, pre-action systems at ESC and Woodlands Elementary, and Inergen suppression systems at Sanford Middle School. Contact information for vendors is provided, with email addresses listed for service providers. The systematic organization by zone and facility allows for efficient contractor assignment and maintenance scheduling across the district's fire protection infrastructure.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sprinkler System Zone A

Facility Bldg#/Rm# Riser(s) Bldg#/Rm#

(FACP)

Bldg#/Rm# (Inspector test)

Additional Notes (PIV key #'s, bldg. or stairwell locations, etc.)

Site Map

Bldg. #'s Sprinkled

Sprinkler Head count

Carillon Elem.

01-119, 02-110, 03-111, 04-116, 05-106, 06-116, 07-113, 09-108 (8 Wet system Risers)

01-100 and 07-104A

01-127C(wall), 02-101I, 03-117, 04-100(ceiling), 05-113, 06-114C, 07-104A, 09-108

Bldgs. 1-7 and 9 only (all single story blds.), PIV key# 3217 for all locks; all control valves key# 863; 6 FDC's, 6

PIV's, 1 BFP, 4 hydrants

Yes 1-7, 9

Bldg. 1: 61, Bldg. 2: 91, Bldg. 3: 111, Bldg. 4: 137, Bldg. 5: 106, Bldg. 6: 146, Bldg. 7: 55, Bldg. 9: 276

Casselberry Elementary 1075 Crystal Bowl Circle Casselbery, 32707

01-037A

FACP 01-

038, FAAP

01-001 01-037A

01/12/22, the site is under construction. Bldg. 1 (2 story), PIV's 1, FDC's 1, backflows 3, 2 hydrants.

YES Bldg 1 ?

Chiles M.S.

01-035, 02-014, 02-218, 03-003, 03-203, 04-003, 04-203, 05-020 (5 Wet system Risers)

01-018J

01-034, 02-014, 02-218, 03-003, 03-203, 04-003, 04-203, 05-018

Bldgs. 1-5 only, Bldgs. 2-4 are 2-stories, key #3217 PIV's bldgs. 1, 2, 3, and 4, key #356 for 2 BFP's and bldg. 5 PIV, 3 hydrants

Yes 1-5

Bldg. 1: 277, Bldg. 2: 359, Bldg. 3: 341, Bldg. 4: 361, Bldg. 5: 349

Eastbrook Elem.

01-047, 01-022B, 02-013, 03-013

(4 Wet system Risers)

01-001, and 03-015

(CER room) within Media Center 03-006

01-007, 02-002A(ceiling), 03-013, 03-213, 04-003E(ceiling)

Bldgs. 1-5 only, bldgs. 1, 2, 4, and 5 are one story, and building 3 is 2-story, 4 PIV's (key#'s 356 and 3217), 2 BFP's (key# 412), 3 hydrants, and 4 FDC's

Yes 1-5

Bldg. 1: 419, Bldg. 2: 82, Bldg. 3: 209, Bldg. 4: 419, Bldg. 5: 71

Evans Elem.

01-136A(sw) and

01-259A(sw) (1 Wet system Riser)

01-102M and 01-141

01-136A(sw) and 01-259A(sw)

Bldg. 1 only (2-story), key# 3217 for CV's on Riser; 2 hydrants,1 FDC, 2 BFP's, no PIV's on campus

Yes 1 Bldg. 1: 1012

Facilities Maintenance 820 East S.R.

434 Winter Springs, FL

32708

N/A 02-002 N/A Hydrants & Backflow YES N/A N/A

Hagerty H.S.

01-127, 02-107, 03-109, 04-108, 05-118B, 06-123, 07-110, 08-100G, 09-111, 09- 123 (10 Risers)

01-123, 02-121, 03-107, 04-117, 06-124, 07-109, 08-202A, 09-120L

01-105(wall), 02-115A, 03-125A, 04-109, 05-115, 06-123, 07-110, 08-100G, 08-101F (Aux. drain), 09- 111, 09-123

Bldgs. 1-9 only; bldgs. 1, 4, 5, 8, and 9 are one story, bldgs.

2, 3, 6, and 7 are 2-stories; all PIV's key# 863; 10 FDC's, 10

PIV's, 1 BFP, 9 hydrants

Yes 1-9

Bldg. 1: 81, Bldg. 2: 396, Bldg. 3: 442, Bldg. 4: 235, Bldg. 5: 176, Bldg. 6: 439, Bldg. 7: 406, Bldg. 8: 258, Bldg. 9: 437

Bldg#/Rm# (Inspector test)

Additional Notes (PIV key #'s, bldg. or stairwell locations, etc.)

Site Map

Bldg. #'s Sprinkled

Sprinkler Head count

Indian Trails M.S.

03-112, 04-107, 05-103, 06-122(sw), 06-222(sw), 07-124(sw), 07-224(sw)

(5 Wet system Risers)

01-123

03-102A, 03-112, 04-101A (wet), 04-104, 04-107 (dry), 05-101B, 05-103, 06- 122(sw), 06-222(sw), 07-124(sw), 07-224(sw)

Bldgs. 1, 2, 3, 4, 5, 6, and 7;

bldgs. 1, 2, 3, 4, and 5 are one story; bldgs. 6 and 7 are 2-stories; 5 PIV's key# 412, 4 hydrants, 3 FDC's, and 2

BFP's key# 412; key SKD-5 for 04-101A IT room; 2 wall OSY's key# 412; Nitrogen dry system 04-107, Aux. drain 01-128B, 04-105, and 05-105; test nitrogen system from Riser 04- 107 with test and flow switch;

IT's for nitrogen dry system outside of 05-100 in fenced area and outside 02-100

Yes 1-7

Bldg. 1: 145, Bldg. 3: 91, Bldg. 4: 140, Bldg. 5: 143, Bldg. 6: 431, Bldg. 7: 439

JHMS

02-004, 08-122E, 09- 004 (3 Wet system

Risers)

05-001N, 05-007G, and 08-104

02-012A, 02-203, 08-113, 09-004, 09-204

Bldgs. 2 (2-story), 8 (one story), and 9 (2-story)only;

1 PIV (key# 412), 2 hydrants (hydrant by bldg. 8 sets off fire alarm), 2 BFP's(key# 412), and 2 FDC's, 02-207A

Aux.drain and CV

Yes 2, 8, and 9 Bldg. 2: 219, Bldg. 8: 154, Bldg. 9: 191

Keeth Elem.

01-039 (2 Wet systems for building 1 and 1 Dry system for kitchen of building 1)

01-016 01-039 Bldg. 1 (one story); No PIV's on campus, 1 FDC, 1 BFP

(key# 412), 2 hydrants Yes 1 Bldg. 1: 661

Lake Howell H.S.

01-100, 02-102, 03-119, 05-004

(4 Wet system Risers)

01-123 and 03-107

01-100, 02-102, 03-119, 05-009A(wall)

Bldgs. 1 (one story), 2 and 3 (both 2-stories), and 5 (stage and stage area, one story) only, 10 hydrants, 4 PIV's and 1 WPIV (key# 412), 5 FDC's, and 3 BFP's (key# 412)

Yes 1, 2, 3, 5

Bldg. 1: 331, Bldg. 2: 290, Bldg. 3: 278, Bldg. 5: 90

Lawton Elem. 02-001F 01-010 02-102(wall)

Bldg. 2 only (one story), BFP key# 464, 1 FDC on BFP, no

PIV's on campus, 2 BFP's and 1 hydrant

Yes 2 Bldg. 2: 232

Layer Elem. 01-143 01-102M and 01-141

01-136(sw,ceiling), 01-106(sw,ceiling), 01-256B(sw,ceiling)

Bldg. 1 only (one story); no PIV's on campus, 3 hydrants, 1 FDC, and 1 BFP(on Riser), Aux. drain 01-120(ceiling)

Yes 1 Bldg. 1: 967

Lyman H.S.

03-032A, 04-024, 04-209, 06-002, 07-102M, 08-023, 09-

01-001, 01-045, 02-017, 03-, 04-, 06-037, 07-115, 08- 019, 09-015

02-036, 03-013A, 04-024, 04-209, 06-002, 07-102F, 08-002D, 09-018

Bldgs. 2, 3, 6, 8, and 9 (one story) and bldgs. 4 and 7 (two story) only; 5 BFP's key# 412;

2 BFP's on road no key #, Bldg. 9 PIV on campus, Bldg 9 wet & dry system, 4 hydrants, 5 FDC's, Aux. drain 02-036, quarterly inspections

Yes 2, 3, 4, 6, 7, 8, and

Bldg. 2: 290, Bldg. 3: 350, Bldg. 4: 367, Bldg. 6: 241, Bldg. 7: 57, Bldg. 8: 341, Bldg. 9 ?

Bldg#/Rm# (Inspector test)

Additional Notes (PIV key #'s, bldg. or stairwell locations, etc.)

Site Map

Bldg. #'s Sprinkled

Sprinkler Head count

Oviedo H.S.

01-050, 02-023, 04-013A, 05-027(sw), 06-006A, 07-014, 08-015B, 09-006, 10-008, 11-004, 12-025, and 13-018

01-042, 02-009, 04-007, 05-002A, 07-007A, 08-040, 09-003K, 11-009, 13-003

01-050, 02-018, 04-006F, 05-005E, 06-006A, 07-002A, 08-015B, 09-006, 10-008, 11-007(wall), 12-025, 13-008A

Bldgs. 1, 2, 4, 5(key#464), 6, 7, 8, 9, 10, 11, 12, and 13;

bldgs. 5 and 8 are 2-story, rest of bldgs. are one story; 8 hydrants; Aux. drains 02-019, 02-003A, 04-008

Yes

1, 2, 4, 5, 6, 7, 8, 9, 10, 11, 12, and

Bldg. 1: 285, Bldg. 2: 250, Bldg. 4: 200, Bldg. 5: 439, Bldg. 6: 39, Bldg. 7: 211, Bldg. 8: 744, Bldg. 9: 190, Bldg. 10: 76, Bldg. 11: 116, Bldg. 12: 176, Bldg. 13: 306

Partin Elem. 05-007D 01-014 05-007C

Bldg. 5 (one story) stage area only, key# 863 for Riser CV, PIV, and BFP; 3 BFP, 1 FDC, 1 PIV, and 4 hydrants

Yes 5 Bldg. 5: 15

Pine Crest Elementary 01-028F, 02-001 01-001 01-028F, 02-001

Building 1 (2 story), Bldg. 2 Chiller. 3 hydrants, 3 backflows, 2 PIV's, 2 FDC's Yes 1 & 2 ?

Rainbow Elem. 04-001F 01-001 04-001F

Stage area only of building 4 (one story); Riser CV key# 863, 4 FDC's, 4 hydrants, 1 BFP, 15 FDV's, no PIV's on campus; all hose connections on outside of buildings are dry, must test using fire hydrants

Yes 4 Bldg. 4: 11

South Sem.

M.S.

01-018, 02-007, 03-041B, 03-241, 03-337, 04-002, 05-001, 07-010, 08-007

02-008

01-018, 02-007, 03-041B, 03-241, 03-337, 04-002, 05-001, 07-007, 08-007

Bldgs. 1, 2, 3, 4, 5, 7 and 8 only; bldg. 3 is 3-stories, rest of campus is one story; 7 PIV's key# 412, 8 hydrants, 7 FDC's, 2 BFP's, 05-003 (AD), 05-

006(AD), 07-015 (AD), 04-

002(AD),

Yes 1-5, 7, and 8

Bldg. 1: 39, Bldg. 2: 73, Bldg. 3: 950, Bldg. 4: 72, Bldg. 5: 102, Bldg. 7: 126, Bldg. 8: 165

Stenstrom Elem. 02-004B, 07-015 01-002, 07-

001A 02-004A, 07-015

Bldg. 2 stage area only (one story), Bldg. 7 two story, key#

412 for 2 BFP and 2 PIV, 4 hydrants

Yes 2 and 7 Bldg. 2: 24, Bldg.7: 207

Tech. Park 01-139 01-139 01-139

Bldg. 1 only (one story), no PIV's on property, 1 FDC, 2 hydrants, quarterly inspections

Yes 1 Bldg. 1: 213

Tuskawilla M.S.

01-022, 02-008, 03-008, 04-007, 05-031, 06-009 01-007

01-022, 02-008, 03-008, 04-007, 05-031, 05-206, 05-306, 06-009

Buildings 1-6; bldg. 5 is 3-stories and bldgs. 1-4, and 6 are one story; PIV and BFP key# 412; 6 PIV's, 1 FDC at BFP, Aux. drains in 06-003 and 05-031, and 5 hydrants

Yes 1-6

Bldg. 1: 79, Bldg. 2: 78, Bldg. 3: 123, Bldg. 4: 98, Bldg. 5: 1st fl- 327, 2nd fl-335, 3rd fl-338, Bldg.

6: 177

Bldg#/Rm# (Inspector test)

Additional Notes (PIV key #'s, bldg. or stairwell locations, etc.)

Site Map

Bldg. #'s Sprinkled

Sprinkler Head count

25th. PL.

Warehouse

601 east 25th Place

Sanford, FL.

32771

N/A YES N/A Hydrants only YES N/A N/A

Walker Elem. 01-143 01-102M and 01-141

01-136(sw), 01-106(sw), 01-206(sw)

Building 1 only (one story), key# 3217 for BFP; no PIV's on campus, 1 FDC, 2 hydrants Yes 1 Bldg. 1: 933

Winter Springs H.S.

02-105, 02-128, 03-106, 04 back NE(sw), 05 back NE(sw), 07 back NE(sw), 08-110, 09-138

01-110 and 18-

02-100, 02-130, 03-115, 04-113, 05-117, 07-113, 08-121, 09-146

Bldgs. 1-9 only; bldgs. 1, 2, 3, 8, and 9 are one story, bldg. 4-

7 are 2-stories; key# 464 for some WPIV's and breakaway for some WPIV's, access panels, and BFP; 8 WPIV's, 8

FDC's, 7 hydrants, 1 BFP

Yes 1-9

Bldg. 1: 76, bldg. 2: 328, bldg. 3: 92, Bldg. 4: 218, Bldg. 5: 205, bldg. 6: 235, Bldg. 7: 230, bldg. 8: 140, Bldg. 9: 265

Total: Total Hydrants:

sw=stairwell

Flow tamper = shows on fire alarm control panel only as Supervisory Flow IT = sets off the fire alarm and shows as trouble on fire alarm control panel Flow main drain = shows on fire alarm control panel only as Supervisory Flow PIV (if tampered) = shows on fire alarm control panel only as Supervisory Fire pump comes in as Supervisory mailto:Cffp@aol.com

Sprinkler System Zone B

Facility Bldg#/Rm# Riser(s) Bldg#/Rm#

(FACP)

Bldg#/Rm#

(Inspector test)

Additional Notes (PIV key #'s, bldg. or stairwell locations, etc.)

Site Map

Bldg. #'s Sprinkled

Total Fire Sprinkler

Heads

Altamonte Elem., 525 Pineview

Street, Altamonte, FL 32701, (407)-

746-2950

01-002, 05-020(sw), 05-217(sw) 01-008

01-002, 05- 020(sw), 05-

217(sw)

Bldgs. 1-4 are one story and 5 is 2-stories; 2 PIV's, PIV key lock# 412, 2 hydrants

Yes 1, 2, 3, 5 909

Bear Lake Elem., 3399 Gleaves

Court, Apopka, FL 32703, (407)-746-

13-108 01-105 13-125 Bldg. 13 (one story) only;

PIV key#464, 4 hydrants Yes 13 272

ESC (Seminole Administrative Offices), 400 E.

Lake Mary Blvd., Sanford, FL

32773, (407)-320-

01-103, 01-203, 01- 303, 01-403, 02-001, 01-318 (dry Pre-Act) serves IS room

01-309

01-120 01-103, 01-203, 01-303, 01-403

Bldg. 1 (4-stories) only; bldg.

2, 02-001, has fire pump, PIV key# 464; bldg. 1 also has Pre-Act system in 01-

318 serves IS room 01-309, 2 hydrants, quarterly inspections

Yes 1 909

English Estates Elem., 299 Oxford Road, Fern Park, FL 32730, (407)-

746-2850

01-025B, 06-100FI 01-049 01-057, 06-

108A bldgs. 1 and 6 only (both are one story), 1 PIV key lock#

412, 2 hydrants Yes 1 and 6 565

Heathrow Elem., 5715 Markham

Woods Road, Lake Mary, FL 32746, (407)-320-6850

05-007D 01-014 05-007C Bldg. 5 (one story) stage and side rooms only, key lock#

412 on PIV, 3 hydrants Yes 5 20

Hamilton Elem.

1501 East 8th St., Sanford FL. 32771

01-093 01-031F 01-093 3 hydrants, 1 FDC, 1 PIV YES 1 800

Highlands Elem., 1600 Shepard Road, Winter Springs, FL

32708, (407)-746-

01-117 and 01-144 01-127A 01-122 and 01-

Bldg. 1 (2-stories) only, PIV key# 464, 3 hydrants Yes 1 1002

Lake Brantley H.S., 991 Sand

Lake Road, Altamonte

Springs, FL 32714, (407)-746-

03-005, 05-005A, 06-108, 07-109, 08-

109, 09-118 03-010C

03-005, 05- 005A, 06-108, 07-109, 08-

109, 09-105

Bldgs. 3, 5, 6, 7, 8, and 9 only; 5 PIV's key# 412, 4 hydrants (2 along road are City's, 1 by fence City's?)

Yes 3, 5, 6, 7, 8, and 9 400

Lake Brantley South 1100 Sand lake Altamonte

Springs, FL. 32714

N/A Yes N/A Hydrants and backflow only YES N/A N/A

Longwood Elementary 840

Orange Ave.

Longwood, FL.

32750

N/A YES N/A Hydrants only YES N/A N/A

Millennium Middle 2330 East S.R. 46

Sanford, FL. 32771

01-017, 02-013, 03- 013, Satirwell 1st.

floor 04-035, 2nd.

Floor 04-035, 3rd.

Floor 05-025

01-002

FAAP, 01-

203 FACP,

02-010A

FACP, 02-

020 FACP,

03-112A

FACP, 04-

004A

FACP, 05-

008 FACP

01-017, 02-013, 03-013, 04-035 stairwell 1st.

Floor, 04-035 second floor, 04- 035 third floor, 05-025

PIV's Bldg. 1, 2, 3, 4, 5. Fire hose connection stairwells 04-010, 04-035, 04-001.

Hose connection flow/tamper 04-022E. 8 hydrants.

YES 1 thru 5 ?

Milwee M.S., 1341 S. Ronald Reagan Blvd., Longwood, FL 32750, (407)-

746-3850

02-009A, 04-020 03-002 02-010 (Mech.

rm.), 04-020 (mech. rm.)

Bldg. 2 (one story) stage area only, Bldg 4 Gym, 2 PIV's, 2 FCD's key lock#

412, 4 hydrants

Yes 2 & 4 2:22, 4:?

Red Bug Elem., 4000 Red Bug

Road, Casselberry, FL 32707, (407)-746-

01-024, 02-130, 03- 118, 04-017(sw landing)

01-001, 01-031, 01-039, 02-102, 03-106, 04-015(CER),

04-204(wall)

Bldgs. 1-3 are one story and bldg. 4 is 2-stories; PIV key# 0464, 3 hydrants, 3 FDC's

Yes 1-4

Rinehart Annex, 239 Rinehart

Road, Lake Mary, FL 32746, (407)-

01-026 01-001A 01-010 Bldg. 1 (one story) only, no PIV's on property, 1 hydrant Yes 1 94

Rock Lake M.S., 250 Slade Drive, Longwood, FL

32750, (407)-746-

01-912 (4 risers) 01-917 01-201, 01-202, 01-404, 01-421, 01-912

Bldg. 1 (one story) only, no PIV's on campus; 1 FDC, 3 hydrants Yes 1

1st floor:

1176, 2nd floor:

Teague M.S., 1350 McNeil Road, Altamonte Springs, FL

32714, (407)-320-

04-107, 06-122, 07- 122 01-100

04-101A, 06-122(sw), 06-222(sw), 07-122(sw), 07-224(sw)

Bldg. 4 (one story) stage area and bldgs. 6 and 7 (2-stories); 3 PIV's key# 412, 6 hydrants

Yes 4, 6, and 7 804

Transportation building 2 at "Tire Storage" garage area 01-006 Bldg. 2

(garage door 2)

Bldg. 2 only (one story), 1 FDC at "Tire Storage" garage area, 4 hydrants, 1 PIV combo 9401; all BFP's key #464

Yes 2 Bldg. 2:

Winter Springs Elem.

01-002, 02-016(sw), 02-216A(sw), 04-002

01-008 and 02-015

02-016(sw), 02-216A(sw), 06-007A, 07-

006E

Bldgs. 1, 2, 3, 5, 6, and 7 only; bldgs. 1, 3-7 are one story, and bldg. 2 is 2-stories; key# 412 for PIV's;

3 hydrants, 3 FDC's, 3 PIV's, 2 BFP's

Yes 1-3, 5-7

Total: 847, did not do by bldg.

number

Woodlands Elem., 1420 E.E.

Williamson Road, Longwood, FL

32750, (407)-746-

02-125, 02-218;

Pre-Act 02-105 02-107 02-125(ceiling), 02-219

Bldg. 1 and 3 (one story) and bldg. 2 (2 -story) only; 02-

125, 02-218; Pre-Act (dry) system covers 02-107, 02- 101, and 02-211; 1 BFP,1

FDC, 4 hydrants, no PIV's on campus

Yes 1-3 651

Total: Total fire hydrants:

sw=stairwell

Flow tamper = shows on fire alarm control panel only as Supervisory Flow IT = sets off the fire alarm and shows as trouble on fire alarm control panel

Flow main drain = shows on fire alarm control panel only as Supervisory

LBHS hydrants not marked, 2-3 are City's Lake Brantley South hydrants not marked mailto:farrellfireprotection@yahoo.com

Sprinkler System Zone C

Facility Bldg#/Rm# Riser(s) Bldg#/Rm#

(FACP)

Bldg#/Rm#

(Inspector test)

Additional Notes (PIV key #'s, bldg. or stairwell locations, etc.)

Site Map

Bldg. #'s Sprinkled

Total Fire Sprinkler Heads

Bentley Elem. 01-136(sw), 03-108 01-102M 01-114, 01-128, 03-108

Bldgs. 1 (2-story) and 3 (one story)only, key# 863, 3 hydrants Yes 1 and 3 Bldg. 1:953, Bldg.

3:252

Crooms AOIT 01-122, 02-103A, 03-

01-101B, 03-

01-122, 02-103A, 03-025

Bldgs. 1 (2-story) Blgd 2 & 3 (one story) only, 3 hydrants, 2 PIV, 2 FDC, 2 BF's Yes 1,2 & 3 1-2: 524, Bldg 3: ?

Crystal Lake Elem. 01-140 01-124D

01-101i, 01-100R(sw), 01-214

Bldgs. 1 (2-story) only, 3 hydrants. BFP key#? Yes 1 919

Early Learning Center, "Old"

Hopper Center 01-114 01-105 01-101(ceiling)

Bldg. 1 only (one story), FDC and OSY on road, PIV key#

464, no fire hydrants Yes 1 155

Endeavor School

02-010, 03-011, 04- 016, 06-011

01-001, 08-001

01-017, 02-010, 03-011, 04-016, 06-011

4 fire hydrants, 5 FDC's, and 5 PIV's and 3 BFP's (all key

#0464) Yes 2-4, 6

Bldg. 2:87, Bldg.

3:52, Bldg. 4:80, Bldg.

6:61

Environmental Studies center 2985 Osprey

Trl. Longwood, FL. 32714

N/A YES N/A Steel underground storage tank 12,000 Gal. YES N/A N/A

Educational Support

Center Annex 02-128A, 03-104 01-, 02-128

02-128A, 03-104, 01-vault of old Rays of Hope

Bldgs. 1-3 (one story), Building has 1 system

(shares with Rays of Hope), no PIV's, 2 hydrants

Yes 1-3 2 systems: Print shop

Forest City Elem. 01-002B, 03-017 01-014 and

03-007L 01-002B, 01-043, 03-007D Bldg. 1 (one story) and 3 (2-story) only, 4 hydrants Yes 1 and 3 Bldg. 1:402, Bldg.

3:415

Geneva Elementary 275 First St.

Geneva, FL.

32732

N/A YES N/A Well Only. Hydrants & backflow. YES N/A N/A

Goldsboro Elem.

06-111, 07-107, 09- 103 06-104F 06-104H, 07-107, 09-105

Bldgs. 6 and 9 (one story), and 7 (2-story) only, PIV key

# 464, BFP key # 464, 2 hydrants, 3 FDC's

Yes 6, 7 and 9 3 systems: Bldg.

6:101, Bldg. 7:303, Bldg. 9:102

Greenwood lakes Middle

601 Lake Park Dr. Lake Mary, FL. 32746

N/A YES N/A Hydrants only YES N/A N/A

Idyllwilde Elem. 02-001, 04-102(sw) 01-103 02-001, 04-

102(sw)

Bldgs. 1 and 2 (one story) and 4 (2-story) only, has fire jockey pump outside front of school, 2 hydrants; has 2 underground water storage tanks (2-30,000 gallon fiberglass tanks with suction pumps rated at 450 GPM flow each, connected by a 6 inch ductile iron pipe to well)

Yes 1, 2, and 4 ?

Journey's Academy 02-128A, 03-104 04-100 01-106, 02-128A, 04-100

Bldgs. 1, 2 and 4 only (all one story); 1 hydrant; shares with ESC Annex No 1, 2, and 4 230

Lake Mary Elem. 08-015 01-107, 08-007L

08-201A and 08-001E (sw) 1st floor

Bldg. 8 (2-story), 4 hydrants, 1PIV key # 10R41 Yes 8 Bldg. 8:278

Lake Mary H.S.

01-134, 01-217A, 01-244A, 01-251A, 03-115, 04-201C

01-226

01-101E, 01- 171C, 01-244A, 03-108A(AD),

03-119D, 04-

201C

Bldgs. 1 and 4 (2-story) and 3 (one story) only, OSY key# 356, 03-115 riser gate key# 3217; 7 hydrants, 2 FDC's, 2 BFP's, no PIV's on campus

Yes 1, 3, and 4 Bldg. 1:1729, Bldg.

3:350, Bldg. 4:186

Lake Orienta Elem.

01-051N, 02-019, 06-007A 02-006N

01-036B, 02-005(sw), 02-216, 04-002, Bldgs. 1-7; bldgs. 1, 3-7 are one story and building 2 is 2-stories; 2 PIV's, 3 FDC's, 2 hydrants

Yes 1-7 Bldg. 1:477, bldg.

2:334, Bldg. 4:157, Markham Woods M.S.

01-008A, 02-014, 02-218, 03-003, 03-203, 04-008, 04-207, 05-020, 06-014

01-018H

01-008A, 02-014, 02-218, 03-003, 03-203, 04-008, 04-207, 05-020, 06-014

Bldgs. 1-7 only; bldgs. 1, 3, 4, 5, 6, and 7 are one story, and bldg. 2 is 2-stories; 5 hydrants; BFP on each riser total of 6

Yes 1-6

9 systems: Bldg.

1:127, Bldg. 2:353, Bldg. 3:322, Bldg.

4:343, Bldg. 5:285, Bldg. 6:150

Midway Elem.

(New) 2638

Brisson Ave.

Sanford,Fl.

32771

01-140, 04-020 01-124D 01-101N, 01-126 (wall), 01-140

Bldg. 1 and Bldg. 4 (2-stories); 5 hydrants, 2 FDC, 2 BFP, 2 PIV

Yes 1 Bldg. 4: 207, Bldg.

1:935 3 systems

Midway Elementary (Old) 2251 Jitway Ave.

Sanford, 32771

N/A YES N/A N/A YES N/A N/A

Midway Safe Harbor 14-outside 14-101 14-101(back left corner) Bldg. 14 only (one story); 1 hydrant Yes 14 1 system, 101

Midway Transportation

01-013 Wet, 01-017 Antifreeze

01-001A, Annun. in 01-001

01-013 Wet, 01-017 Aux. drain, outside of 01-006

Dry

Bldg. 1; 4 fire hydrants, 1 FDC, 1 PIV, 2 BFP's 1 2 systems: 131

Seminole 9th Grade Center

40-127, 41-118, 42-101, 43-102, 44-025, 44-257, 44-160A, 44-254

44-102

40-104, 41-115, 42-112A, 43-102, 44-025, 44-257, 44-160A, 44-254

Bldgs. 40, 41, 42, 43, and 44 only; bldg. 41 stage standpipe only; bldg. 44 is 2-stories and bldgs. 40-43 are one story; no IT; 7 hydrants

Yes 40-44

Bldg. 40:59, Bldg.

41:260, Bldg. 42:108, bldg. 43:25, Bldg. 44:

4 systems, 844

ESC Annes 02-128A

01-, Electrical closet at front desk

Building 1 back vault

One story; included in ESC Annex inspection, fire alarm panel not tied into fire sprinkler system, 1 hydrant

Yes 1 208

Sabal Point Elem.

01-053, 02-019, 06- 005A 02-006N

01-014(AD),

02-016, 02-214, 04-004, 07-006E

Buildings 1-7; bldgs. 1, 3-7 are one story and bldg. 2 is 2-stories; 1 hydrant, 3 PIV's key# 10R41, 3 FDC's

Yes 1-7 Bldg. 1:430, Bldg.

2:255, Bldg. 6:114, Sanford M.S. 02-106, 10-034 02-127N 02-125, 10-030

Bldg. 2 (2-story bldg.) and bldg. 10 (stage area one story) only; Inergen system 02-127, 02-209 and 02-

227 (no longer exists, taken out), 3 hydrants

Yes 2 and 10 2 systems: Bldg.

2:566, Bldg. 10:20

Seminole H.S.

01-001B, 02-009, 03-028, 04-025, 04-218?, 05-016B, 05-218, 06-023, 07-117A, 08-006, 10-003B, 10-205, 11-016B, 12-021, 13-024C, 13-228, 14-017, 14-221, 16-001, 17-013

01-044, 02-002H, 03-035, 04-210C, 05-210C, 06-002F, 07-117A, 08-007, 10-210C, 11-007, 12-011, 13-019, 14-012, 16-001, 17-010

01-001B, 02-007, 03-028, 03-038, 04-025, 04-218

05-016B, 05-218, 06-002D, 07-112, 08-006, 10-016, 10-218, 11-001A, 12-025, 13-008C, 13-024C, 13-228, 14-016 (wall), 14-215, 16-001, 17-009

Bldgs. 1, 2, 3, 4, 5, 6, 7, 8, 10 (pressure gauge above ceiling 10-003B), 11, 12, 13, 14, 16, and 17 only; bldg.13 has 2 dry systems on outside balcony 1st and

2nd floors, bldgs. 1-3, 6-8, 11-12, 16-17 are all one story; bldg. 3 (several areas) has an Antifreeze system; bldgs. 4, 5, 10, 13, and 14 are 2-stories; 13 hydrants, 14 PIV's (bldgs. 3 and 10 key #10R41 and rest of bldgs. key #0356), 14 FDC's, BFP's on risers for bldgs. 12(2), 17(2), 11(2), 7(2), 6(2)

Yes

1, 2, 3, 4, 5, 6, 7, 8, 10, 11, 12, 13, 14, 16, and 17

Bldg. 1:157, Bldg.

2:170, Bldg. 3:113, Bldg. 4:172, Bldg.

5:345, Bldg. 6:187, Bldg. 7:92, Bldg.

8:181, Bldg. 10:391, Bldg. 11:96, Bldg.

12:270, Bldg. 13:369, Bldg. 16:29, Bldg.

17:204

Spring Lake Elem.

01-053, outside of 02-008, 03-012, 04-

01-013E 01-053, 02-012, 03-006, 04-002

Bldgs. 1-4 are all one story;

3 hydrants, 4 FDC's, 4 BFP's

(2 in front and 2 in back) Yes 1-4

Bldg. 1:344, Bldg.

2:80, Bldg. 3:68, Bldg.

4:73

Sterling Park Elem.

01-051M, 05-108C, 08-015

Ann. 01- 002, 01-

038, 05- 111A, 08-007L

01-051M, 04- 106A, 06- 102C, 08- 001E(sw)1st floor, 08-015 2nd floor

Bldg. 1-6 are one story and bldg. 8 is 2-stories; 4 BFP's key# 863, 6 PIV's silver keys, 4 hydrants, FDC's

Yes 1, 3, 4, 5, 6, and 8

Bldg. 1:474, Bldg.

5:120, Bldg.8:380, Wekiva Elementary 1450 East

Wekiva Trl.

Longwood, FL.

32779

01-005B, 07-008B, 08- 006B, 09-004

01-005B,07- 008B,08-

006, 09-004

FAAP 01-001,

FACP 01-030,

FACP 07-011,

FACP 08-005,

FACP 09-003

4 PIV's, 4 FDC's, 6 hydrants YES 1, 7, 8, 9 ?

Wicklow Elem. 01-136, 01-200 01-149K 01-136, 01-169

(flow test), 01-200 (drain only)

Building 1 (one story) only, 3 hydrants, BFP Key #0464 Yes 1 2 systems: 1005

Wilson Elem. 06-100F 02-105 06-102 (above ceiling)

Building 6 (one story) only, PIV key# 863, 5 hydrants Yes 6 218

Total: Total fire hydrants:

sw=stairwell

Flow tamper = shows on fire alarm control panel only as Supervisory Flow IT = sets off the fire alarm and shows as trouble on fire alarm control panel Flow main drain = shows on fire alarm control panel only as Supervisory

Vendor A
Vendor B
Vendor C