SCO-24-27518-01A Addendum #4.pdf
PDF 5 MB Posted
- Attached to
- North Carolina Department of Natural and Cultural Resources, Division of Parks and Recreation
- Solicitation number
- SCO-24-27518-01A
- Issued by
- Haywood County, North Carolina
About this file
Addendum #4 Summary
This is Addendum #4 to the construction documents for Kerr Lake State Recreation Area Campground and Maintenance Area Improvements, issued by Katherine Hogan Architects on behalf of the North Carolina Department of Natural and Cultural Resources, Division of Parks and Recreation. The addendum, dated August 13, 2026, modifies the original project manual and construction documents dated July 1, 2026, for SCO #24-27518-01A. The changes address revisions to civil and architectural drawings to ensure consistency across multiple sheets. Civil drawing revisions include Sheet CE132-1 (Erosion Control Plan – Nutbush North) and Sheet CU132-1 (Utility Plan – Nutbush North), both revised for consistency with storm items and grading shown on Sheets L132A and L132B. Additionally, Sheet CE134A (Erosion Control Plan – Satterwhite Point) and Sheet CU134A (Utility Plan – Satterwhite Point) were revised for consistency with background materials shown on Sheet L134A. Architectural revisions include clarification of roof and wall panel intent for the pre-engineered metal building (PEMB) on Sheet A-00.01 (Subsystems & Partition Types) and clarification of overhead coiling door dimensions on Sheet A-05.00 (Door Schedule, Elevations, and Details). All bidders of record must acknowledge receipt of this addendum in their bid forms, with failure to do so potentially resulting in bid disqualification.
The addendum does not introduce new pricing terms, set-asides, or funding requirements but rather serves as a technical clarification document to ensure bidders are working from consistent and accurate design information. The revised drawings maintain the project's scope involving campground and maintenance area improvements at two locations within Kerr Lake State Recreation Area—Nutbush North and Satterwhite Point—with particular attention to erosion control measures, utility installations, and building construction standards compliant with North Carolina Department of Environmental Quality standards and applicable building codes.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SCO ID#24-27518-01A-Addendum #3.pdf | ||
| SCO-24-27518-01A-Addendum #1.pdf | ||
| SCO # 24-27518-01A-Addendum #2.pdf | ||
| SCO-24-27518-01A-NTB.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
raleigh 553-c pylon drive raleigh, north carolina 27606, usa p 919.793.5063
ADDENDUM 04
Date: 13 August 2026
Project: Kerr Lake State Rec Area: Campground & Maintenance Area Improvements
NC State Parks Kerr Lake State Recreation Area
SCO #: 24-27518-01A
To: ALL PRIME BIDDERS OF RECORD
This Addendum forms a part of the Contract Documents and modifies the original Project Manual and Construction Documents dated July 1st, 2026. Please acknowledge receipt of this Addendum in the space provided in the Bid Form.
Failure to do so may subject the Bidder to disqualification.
Items: CHANGES TO THE PROJECT DRAWINGS:
Civil:
• Sheet CE132-1 - EROSION CONTROL PLAN – NUTBUSH NORTH o This Sheet has been revised for consistency with background
(storm items) shown on Sheet L132A and grading shown on Sheet L132B.
• Sheet CU132-1 - UTILITY PLAN – NUTBUSH NORTH o This Sheet has been revised for consistency with background
(storm items) shown on Sheet L132A and grading shown on Sheet L132B.
• Sheet CE134A – EROSION CONTROL PLAN – SATTERWHITE POINT
(materials) shown on Sheet L134A.
• Sheet CU134A – UTILITY PLAN – SATTERWHITE POINT
(materials) shown on Sheet L134A.
Architecture:
• Sheet A-00.01 – SUBSYSTEMS & PARTITION TYPES o Clarified intent for roof and wall panel of PEMB.
• Sheet A-05.00 – DOOR SCHEDULE, ELEVATIONS, AND DETAILS o Clarified dimension of overhead coiling door.
END OF ADDENDUM NUMBER FOUR
KHA
Snapshot
KHA
Text Box 08/13/2026
VAN
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TPTPTPTPTPTP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP TP TP TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
E
E
325324
FFE 329.50
329328
+ LP
+ LP
+ HP
5:
3:1
3:1
5:1
6:1
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM FM FM FM FM FM FM FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
ST
PT
SS
PT
YH
W W
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM FM FM FM FM FM FM FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
W
W
W
W
W
W
W
W
W
W
W
M
BF
CONCRETE
WASHOUT
SILT
FENCE
SILT FENCE
OUTLET (TYP)
RAIN GAUGE/
PERMIT BOX
CONSTRUCTION
ENTRANCE
SF
SF
SF
SF
SF
SFSF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SFSFSFSF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF SF SF
SF
SF
SF
SF
SF SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
LD
LD
LD
LD
LD
LD
LD
LD
LDLD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LDLDLDLD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD LD LD
LD
LD
LD
LD
LD LD
LD
LD
LD
LD
LD
LD
LD LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD LD LD
LD
LD
LD
LD
LD LD
LDLDLD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
FLOOD HAZARD AREA (PER GIS)
(ZONE AE; EL 320)
(MAP NUMBER 3720196600J,
EFFECTIVE DATE APRIL 16, 2007)
SF SF
SFSF
SF
SF
SF
SF
SF
SF
SF
SF
SF
REPAIR
DRAINFIELD
(NIC)
SF
SF
CE132-1
LD
EROSION CONTROL LEGEND
SILT FENCE
LIMITS OF DISTURBANCE
SF
SILT FENCE OUTLET
CONSTRUCTION ENTRANCE
SEE SHEET C600 FOR SELF-INSPECTION REQUIREMENTS.
THE FINANCIALLY RESPONSIBLE PERSON AND/OR HIS AGENT WILL BE PERFORMING
SELF INSPECTIONS OF THE EROSION AND SEDIMENTATION CONTROL MEASURES USING
NCDEMLR'S SELF INSPECTION REPORT (WORKSHEET) AND THIS WILL BE KEPT
ONSITE.
SEE SHEET C600 EROSION CONTROL
CONSTRUCTION SEQUENCE.
SELF-INSPECTION RULES
SEE SHEET C600 FOR ADDITIONAL EROSION
CONTROL NOTES.
SHEET TITLE
SHEET NUMBER
SHEET ISSUE
SCO ID NO.
KHA PROJECT NO.
KERR LAKE STATE
RECREATIONAL
AREA
IMPROVEMENTS
NO. DATEDESCRIPTION
24-27518-01A t2307
6254 SATTERWHITE
POINT ROAD
NV5 ENGINEERS AND CONSULTANTS, INC.
3300 REGENCY PARKWAY, SUITE 100
CARY, NC 27518
P: 919.851.1912 www.NV5.com NC License # F-1333
CD PRICING SET 01/23/26
08/22/25 06/14/24
DESIGN DEVELOPMENT
SCHEMATIC DESIGN
CONSTRUCTION DOCUMENTS 02/04/264
5 05/08/26CD - SCO FINAL REVIEW
6 07/01/26BID DOCUMENTS
SCALE: 1" = 20'-0"1 EROSION CONTROL PLAN - NUTBUSH NORTH
DISTURBED AREA = 2.33 AC. (TOTAL FOR NUTBUSH NORTH)
MA
TC
HL
IN
E
- S
EE
C
E1
-2
1. DURING ALL PHASES OF CONSTRUCTION, GROUNDCOVER ON EXPOSED SLOPES
SHALL BE PROVIDED ACCORDING TO GROUND STABILIZATION TABLE (SHEET
C600) FOLLOWING COMPLETION OF ANY PHASE OF GRADING.
2. FINAL PERMANENT GROUNDCOVER FOR ALL DISTURBED AREAS SHALL BE
PROVIDED ON ALL DISTURBED AREAS ACCORDING TO GROUND STABILIZATION
TABLE (SHEET C600) FOLLOWING COMPLETION OF CONSTRUCTION OR
DEVELOPMENT.
3. THE ABOVE REQUIREMENTS ARE THE MINIMUM NECESSARY TO MEET EROSION
AND SEDIMENT CONTROL REGULATIONS.
4. SLOPE EROSION CONTROL MATTING SHALL BE INSTALLED FOR TEMPORARY
STABILIZATION DURING THE ESTABLISHMENT OF VEGETATIVE COVER ON ALL
STEEP SLOPES (6:1 OR STEEPER). NO SYNTHETIC, PLASTIC OR NYLON MATERIALS
MAY BE USED. MATTING MUST BE 100% NATURAL FIBER, SUCH AS A COIR.REFER
TO MATERIAL SPECIFICATIONS. INSTALL MATTING PER MANUFACTURER'S
INSTRUCTIONS.
5. ALL OTHER SEEDED AREAS SHALL BE MULCHED WITH STRAW AND TACKED WITH
CELLULOSE HYDROMULCH, WOOD FIBER HDYDROMULCH OR ENHANCED WOOD
FIBER HUDROMULCH. ASPHALT IS NOT ALLOWED AS A TACKING AGENT ON DPR
PROJECTS.MALACHITE GREEN DYE OR OTHER DYE DERIVATIVES ARE ALSO NOT
ALLOWED DURING HYDROSEEDING/HYDROMULCHING OPERATIONS.
GROUND STABILIZATION SHALL BE PROVIDED ON ALL DISTURBED AREAS ACCORDING
TO GROUND STABILIZATION NOTES. SEE SHEET C600.
EXTENSIONS OF TIME MAY BE APPROVED BY THE PERMITTING AUTHORITY BASED ON
WEATHER OR OTHER SITE-SPECIFIC CONDITIONS THAT MAKE COMPLIANCE
IMPRACTICABLE (SECTION II.B(2) (b))
THE REQUIREMENTS ON SHEET C600 ARE THE MINIMUM NECESSARY TO MEET
EROSION AND SEDIMENT CONTROL REGULATIONS.
INSTALL TEMPORARY MATTING FOR STABILIZATION DURING THE ESTABLISHMENT OF
VEGETATIVE COVER ON ALL STEEP SLOPES (6:1 OR STEEPER) AND AREAS OF
CONCENTRATED FLOW (CHANNELS, DITCHES, SWALES, ETC.). NO SYNTHETIC,
PLASTIC OR NYLON MATERIALS MAY BE USED. MATTING MUST BE 100% NATURAL
FIBER, SUCH AS A COIR. REFER TO SPECIFICATION SECTION 312500 FOR MATERIAL
SPECIFICATIONS. INSTALL MATTING PER MANUFACTURER'S INSTRUCTIONS.
SLOPE & SURFACE STABILIZATION
MAINTENANCE PLAN
1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL NCDEQ STANDARDS,
SPECIFICATIONS AND DETAILS.
2. THE CONTRACTOR SHALL COMPLY WITH ALL STATE AND LOCAL CODES IN OBSERVING
EROSION CONTROL MEASURES BOTH ON AND OFF SITE.
3. THE CONTRACTOR SHALL MAINTAIN ALL EROSION CONTROL DEVICES AFTER EACH RAINFALL
EVENT OR AS DIRECTED BY LOCAL AUTHORITIES OR ARCHITECT.
4. ALL STORM DRAINAGE PIPES SHALL BE THOROUGHLY FLUSHED OF ALL SEDIMENT FOLLOWING
SITE STABILIZATION. INTERIOR FLUSHING OF SYSTEM SHALL BE PERFORMED AS NEEDED TO
MAINTAIN PROPER FUNCTIONING OF THE DRAINAGE SYSTEM. CLEANING SHALL BE
PERFORMED IN A MANNER WHICH PREVENTS SEDIMENT FROM BEING FLUSHED
THROUGH PIPES TO THE EXISTING DRAINAGE SYSTEM.
5. THE INDICATED STAGING AREA IS INTENDED FOR VEHICLES AND NON-ERODIBLE MATERIALS
ONLY. NO SOIL, SAND OR OTHER ERODIBLE, FINE GRAINED MATERIAL SHALL BE STORED
OUTSIDE OF THE LIMITS OF THE SITE PROTECTED BY SEDIMENT AND EROSION CONTROL
DEVICES AND MEASURES.
6. ANY DEWATERING OF SEDIMENT CONTAINMENT DEVICES FOR MAINTENANCE,
REMOVAL OR CONVERSION PURPOSES IS TO BE DONE THROUGH A SILT BAG.
7. ANY DEWATERING OF STORM/UTILITY TRENCHES IS TO BE DONE THROUGH A SILT
BAG.
8. CONTRACTOR SHALL USE TIRE WASH STATION OR OTHER MEANS TO PREVENT SEDIMENT
FROM TRACKING ONTO THE ROAD IF CONSTRUCTION ENTRANCE IS FOUND INSUFFICIENT AT
NO ADDITIONAL COST TO OWNER.
EROSION CONTROL NOTES
CONTRACTOR TO STAKE EXTENTS OF TRENCHING REQUIRED FOR ELECTRICAL AND
OTHER SITE WORK FOR CIVIL ENGINEER AND LANDSCAPE ARCHITECT'S FIELD
REVIEW. CONTRACTOR TO FLAG ALL TREES GREATER THAN 1” DBH THAT ARE IN
CONFLICT WITH PROPOSED TRENCH LOCATIONS FOR ELECTRICAL SITE WORK
AND/OR UTILITY WORK.
CONTRACTOR TO LIMIT DISTURBANCE IN THESE AREAS TO ONE (1) WORKING DAY SO
AREA CAN BE STABILIZED AND SEEDED/STRAWED PRIOR TO THE COMPLETION OF
THE WORKING DAY. THIS INCLUDES BUT NOT LIMITED TO UTILITY TRENCHING, DIRECT
BURY AND BORING. IF UNABLE TO COMPLETE ASSOCIATED WORK DUE TO
UNFORESEEN CONDITIONS OR WEATHER ISSUES, CONTRACTOR TO PROVIDE
TEMPORARY EROSION CONTROL MEASURES IN ACCORDANCE WITH NCDEQ
STANDARDS UNTIL WORK HAS BEEN FINALIZED AND AREA HAS BEEN
SEEDED/STRAWED.
SHEET NOTES
EROSION
CONTROL
PLAN -
NUTBUSH
NORTH
NOTE:
THE ENGINEER DOES NOT GUARANTEE THAT ALL EXISTING FACILITIES SUCH AS PIPELINES,
ELECTRICAL LINES, CONDUIT, TELEPHONE CABLE, SERVICE CONNECTIONS, OR OTHER FACILITIES ARE SHOWN ON THE PLANS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO HAVE ALL UTILITIES LOCATED BY THEIR RESPECTIVE OWNERS, FIELD MARK THE UTILITY LOCATIONS, AND PROTECT ALL SUCH EXISTING FACILITIES PRIOR TO BEGINNING CONSTRUCTION. THE CONTRACTOR IS FULLY
RESPONSIBLE FOR NOTIFYING ALL UTILITY OWNERS.
GRADING NOTE:
ELEVATIONS SHOWN ON THIS SHEET WERE PROVIDED BY SURFACE678. REFER TO L SHEETS FOR ADDITIONAL INFORMATION. BRING ANY DISCREPANCIES TO THE ENGINEER PRIOR TO ORDERING &
INSTALLATION OF EROSION CONTROL MEASURES SHOWN ON THIS SHEET.
7 08/12/26ADDENDUM 03
THIS SHEET HAS BEEN REVISED FOR CONSISTENCY
WITH BACKGROUND (STORM ITEMS) SHOWN ON
SHEET L132A AND GRADING SHOWN ON SHEET L132B.
KHA
Image
KHA
Text Box
KHA
Image
KHA
Line
KHA
Line
Line
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
E
E
FLOOD HAZARD AREA (PER GIS)
(ZONE AE; EL 320)
(MAP NUMBER 3720196600J,
EFFECTIVE DATE APRIL 16, 2007)
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM FM FM FM FM FM FM FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
ST
PT
SS
PT
4" PVC SANITARY
SEWER SERVICE
SEPTIC TANK.
SEE SEPTIC NOTES.
PUMP TANK.
SEE SEPTIC NOTES
& ELECTRICAL.
4" PVC CLEANOUT
TOP: 329.24'
(FLUSH W/ STONE
OF UTILITY YARD)
INV.: 323.80'
SEE PLUMBING FOR
CONTINUATION.
TIE TO PROPOSED SEPTIC
SYSTEM (MIN. 1% SLOPE).
REFER TO SEPTIC NOTES.
FORCEMAIN. SEE
SEPTIC NOTES.
2" PVC WATER
SERVICE
TIE TO EXIST.
2-IN. WATERLINE
UNDERGROUND
PROPANE TANK.
SEE PLUMBING.
SEE PLUMBING FOR
CONTINUATION.
YH
W W
3/4" DOMESTIC
WATER SERVICE
3/4" SHUT-OFF
VALVE IN VALVE BOX
TIE TO EXIST.
WATERLINE
YARD HYDRANT
2" GATE VALVE 2" DOM. METER
2" BACKFLOW
SEE WATER
NOTES.
2" GATE
VALVE
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM FM FM FM FM FM FM FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
MANIFOLD (REPAIR).
SEE SEPTIC NOTES.
MANIFOLD. SEE
SEPTIC NOTES.
SEE ELECTRICAL
FOR CONTINUATION.
SEE ELECTRICAL
FOR CONTINUATION.
SEE PLUMBING FOR
CONTINUATION.
ELECTRICAL CONDUIT;
SEE ELECTRICAL.
ELECTRICAL CONDUIT;
SEE ELECTRICAL.
SLEEVED IN DIP OR
PIPING ENCASED IN
CONCRETE. SEE
SEPTIC NOTES.
W
W
W
W
W
W
W
W
W
W
W
2" ISOLATION
GATE VALVE
2" PVC WATER LINE
CONNECT TO EXIST.
2-IN. WATERLINE
2" GATE
VALVE
M
BF
FORCEMAIN (REPAIR)
(NIC). SEE SEPTIC
NOTES.
INFILTRATION PIPE;
SEE LANDSCAPE
PLANS.
INFILTRATION PIPE;
SEE LANDSCAPE
PLANS.
REPAIR
DRAINFIELD
(NIC)
FORCEMAIN (REPAIR)
(NIC). SEE SEPTIC
NOTES.
ELECTRICAL TRANSFORMER;
SEE ELECTRICAL.
ELECTRICAL PEDESTAL;
SEE ELECTRICAL
CU132-1
1. ALL SEPTIC RELATED ITEMS ARE SHOWN FOR REFERENCE PURPOSES ONLY. THIS
INCLUDES BUT NOT LIMITED TO TANKS, PUMPS, FORCEMAIN, MANIFOLD,
CONTROLS AND OTHER ASSOCIATED PIPING.
2. REFER TO PRESSURE MANIFOLD SYSTEM ENGINEERED OPTION PERMIT PLANS
TITLED ' KATHERINE HOGAN ARCHITECTS KERR LAKE STATE PARK (NUTBRUSH
BRIDGE) PREPARED BY MACCONNELL & ASSOCIATES, P.C. DATED 04/29/2026 OR
LATEST VERSION FOR ADDITIONAL INFORMATION.
3. ALL REPAIR DRAINFIELD ITEMS (AREA 2, OR ZONE 2) ARE SHOWN FOR SCHEMATIC
PURPOSES ONLY AND NOT INCLUDED IN CONTRACT. THIS INCLUDES BUT NOT
LIMITED TO LEACH FIELD, FORECEMAIN, MANIFOLD AND OTHER OTHER RELATED
COMPONENTS. REFER TO SEPTIC DRAWINGS FOR CLARIFICATION.
4. REFER TO ELECTRICAL DRAWINGS FOR POWER REQUIREMENTS.
SEPTIC (NUTBUSH NORTH) NOTES
SHEET TITLE
SHEET NUMBER
SHEET ISSUE
SCO ID NO.
KHA PROJECT NO.
KERR LAKE STATE
RECREATIONAL
AREA
IMPROVEMENTS
NO. DATEDESCRIPTION
24-27518-01A t2307
6254 SATTERWHITE
POINT ROAD
NV5 ENGINEERS AND CONSULTANTS, INC.
3300 REGENCY PARKWAY, SUITE 100
CARY, NC 27518
P: 919.851.1912 www.NV5.com NC License # F-1333
CD PRICING SET 01/23/26
08/22/25 06/14/24
DESIGN DEVELOPMENT
SCHEMATIC DESIGN
CONSTRUCTION DOCUMENTS 02/04/264
5 05/08/26CD - SCO FINAL REVIEW
6 07/01/26BID DOCUMENTS
UTILITY LEGEND
WATER
PROPOSED
SANITARY SEWER SERVICE
FORCEMAIN (BY OTHERS)
SCALE: 1" = 20'-0"1 UTILITY PLAN - NUTBUSH NORTH
MA
TC
HL
IN
E
- S
EE
C
U1
-2
UTILITY NOTES
1. VERIFY EXISTING CONDITIONS AND CONNECTIONS TO EXISTING UTILITIES PRIOR TO
CONSTRUCTION. CONTRACTOR MAY NEED TO COORDINATE WITH NC STATE PARKS TO DETERMINE
LOCATION OF EXISTING UTILITIES DUE TO FIELD CONDITIONS. NOTIFY ENGINEER IF ANY
DISCREPANCIES ARE DISCOVERED.
2. DOMESTIC BACKFLOW TO BE FEBCO LF860 OR APPROVED EQUAL WITHIN HEATED ENCLOSURE.
REFER TO ELECTRICAL DRAWINGS FOR POWER REQUIREMENTS. CONTRACTOR TO PROVIDE SHOP
DRAWING FOR APPROVAL PRIOR TO ORDERING AND INSTALLATION.
WATER SERVICE NOTES
UTILITY PLAN
- NUTBUSH
NORTH
NOTE:
THE ENGINEER DOES NOT GUARANTEE THAT ALL EXISTING FACILITIES SUCH AS PIPELINES,
ELECTRICAL LINES, CONDUIT, TELEPHONE CABLE, SERVICE CONNECTIONS, OR OTHER FACILITIES ARE SHOWN ON THE PLANS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO HAVE ALL UTILITIES LOCATED BY THEIR RESPECTIVE OWNERS, FIELD MARK THE UTILITY LOCATIONS, AND PROTECT ALL SUCH EXISTING FACILITIES PRIOR TO BEGINNING CONSTRUCTION. THE CONTRACTOR IS FULLY
RESPONSIBLE FOR NOTIFYING ALL UTILITY OWNERS.
GRADING NOTE:
ELEVATIONS SHOWN ON THIS SHEET WERE PROVIDED BY SURFACE678. REFER TO L SHEETS FOR ADDITIONAL INFORMATION. BRING ANY DISCREPANCIES TO THE ENGINEER PRIOR TO ORDERING &
INSTALLATION OF UTILITY ITEMS SHOWN ON THIS SHEET.
1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL NCDENR STANDARDS,
SPECIFICATIONS AND DETAILS.
2. WATER LINE AND WATER SERVICES TO BE INSTALLED WITH A COVER OF NO LESS
THAN 3-FT TO FINISH GRADE WITH TRACER WIRE IN ACCORDANCE WITH 2018
NCPC 306.2.4 FOR PLASTIC PIPE.
3. SANITARY SEWER SERVICES TO BE INSTALLED WITH A COVER OF NO LESS THAN
3-FT TO FINISH GRADE IN NON-TRAFFIC AREAS, 4-FT TO FINISH GRADE IN
TRAFFIC AREAS IN ACCORDANCE WITH 2018 NCPC 306.2.4 FOR PLASTIC PIPE.
4. ALL UTILITIES TO BE INSTALLED WITH THE REQUIRED CLEARANCES AS INDICATED
IN THE DRAWINGS AND SPECIFICATIONS.
5. WATERLINES AND SEWER LINES SHALL BE INSTALLED WITH A MINIMUM
HORIZONTAL CLEARANCE OF 10-FT.
6. SEWER LINES SHALL BE INSTALLED WITH A MINIMUM VERTICAL CLEARANCE OF
24-IN TO STORM DRAINAGE PIPES. THIS INCLUDES ALL SUB-DRAINAGE PIPES.
7. COORDINATE AND SCHEDULE INSTALLATION OF ALL UTILITIES WITH OTHER PRIME
CONTRACTORS, UTILITY COMPANIES AND OTHER TRADES INCLUDING BUT NOT
LIMITED TO: NATURAL GAS, ELECTRICITY, TELEPHONE AND CATV.
8. VERIFY EXISTING CONDITIONS AND CONNECTIONS TO EXISTING UTILITIES PRIOR
TO CONSTRUCTION. NOTIFY ARCHITECT IF ANY DISCREPANCIES ARE
DISCOVERED.
9. CONTRACTOR IS RESPONSIBLE FOR ALL DAMAGES DURING CONSTRUCTION AND
SHALL MAKE REPAIRS AT NO EXPENSE TO THE OWNER.
10. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE NC STATE BUILDING
CODE AND OSHA REQUIREMENTS.
11. THE CONTRACTOR SHALL PROVIDE AN AS-BUILT SURVEY OF ALL UTILITY AND
STORM DRAINAGE IMPROVEMENTS FOLLOWING CONSTRUCTION.
12. CONTRACTOR SHALL PHASE DEMOLITION AND NEW CONSTRUCTION TO ENSURE
UNINTERRUPTED ACCESS AND UTILITY SERVICE TO ADJACENT FACILITIES.
COORDINATE SHORT-TERM, OFF-HOUR, TEMPORARY SHUT- DOWNS WITH THE
OWNER.
13. SEE GENERAL NOTES ON EXISTING CONDITIONS AND DEMOLITION PLAN FOR
REQUIREMENTS FOR REMOVAL AND PATCHING OF PAVEMENT FOR UTILITY
INSTALLATION.
14. ALL SANITARY SEWER SERVICES SHALL BE 4" PVC (SCH 40) @1.04% MIN. SLOPE
UNLESS INDICATED OTHERWISE. USE DUCTILE IRON WHEN COVER IS LESS THAN
24-IN.
15. NO WORK SHALL BE PERFORMED ON RIGHT-OF-WAYS OR ADJACENT PROPERTIES
UNTIL THE OWNER NOTIFIES CONTRACTOR IN WRITING OF PROCUREMENT OF
APPROPRIATE PERMITS, EASEMENTS, AGREEMENTS, OR RIGHTS-OF-WAY.
16. CONTRACTOR TO FIELD ADJUST PROPOSED SERVICES (WATER & SERVICE) AS
NECESSARY TO RETROFIT EXISTING SITE FEATURES. BRING ANY DISCREPANCIES
TO THE ENGINEER PRIOR TO CONSTRUCTION.
17. SEE SHEET C500 FOR TYPICAL RV SITE UTILITY LAYOUT AND SHEET C502 FOR
ENLARGED PLAN OF SERVICE CONNECTIONS.
7 08/12/26ADDENDUM 03
THIS SHEET HAS BEEN REVISED FOR CONSISTENCY
WITH BACKGROUND (STORM ITEMS) SHOWN ON
SHEET L132A AND GRADING SHOWN ON SHEET L132B.
KHA
Image
KHA
Image
KHA
Line
KHA
Line
E
E
E
E
EEEEEEEE
E E
E E
E
E
TP
TP
TP
TP
TP
TP TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TPTP
TP
TPTPTPTP
TP
TP
TP
TP
TP
TP
TPTPTPTPTP
TPTP
TP
TP
TP
TP
TP
TP
TP
TP TP
TP TP TP TP TP
TP
TP TP
TP
TP
TP
TP
TPTP
TP
TP
TP
TP
TP
TPTPTPTPTPTP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TPTPTP
TP
TP
TP
TP
TPTPTP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP TP TP TP TP
TP
TP
TP
TP
TP
TP
TP TP TP TP TP TP TP TP TP TP TP TP
TP
TP
TP
TP
TP
TP
TP
GT OWS
FM
FM
FM
FM
FM
FM FM FM FM FM FM FM
ST
PT
SP SP SP SP SPSS
SS
SS
SS
SS
SS
PT
W W
W
FM
FM
FM
FM FM FM
MBF
FFE 325.25
8.
M
AX
5.6%MAX
1.3%
2% 325.21
EXISTING ELEVATION AT COLUMNS
+/- 319.50, CONTRACTOR TO V.I.F.
1.
6%
EDGE OF CONCRETE AND TOP OF TIMBER 325.15
ADJACENT GRAVEL 325.00
2.0%
3:1
3:
5.0%
3:1
5.
0%
:1
4:
325.15
325.21
CONCRETE
WASHOUT
CONSTRUCTION
ENTRANCE
RAIN GAUGE/
PERMIT BOX
SILT
FENCE
SILT FENCE
OUTLET (TYP)
SFSF
SF
SF
SF
SF
SF
SF
SF SF SF
SF
SF
SF
SF
SF
SF SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SFSFSFSFSFSFSFSFSF
SF
SF
SF
SFSFSFSF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF SF
SF
SF
SF
SF
SF
SF
SF
SF
SF SF
SF
SF
SF
SF
SF SF SF SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
LD
LD
LD LD
LD
LD
LD
LD
LD LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD LD LD LD LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD LD LD LD LD LD LD LD
LD
LDLD
LD
LD
LD
LD
LD
LD
LD LD LD LD LD
LD
LD
LD
LD
LD
LD
LD LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LDLDLDLDLDLDLDLDLDLD
LD
LD
LD
LD
LD
LDLDLDLDLD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
LD
FLOOD HAZARD AREA (PER GIS)
(ZONE AE; EL 320)
(MAP NUMBER 3720198600K,
MAP REVISED DECEMBER 06, 2019)
FLOOD HAZARD AREA (PER GIS)
(ZONE AE; EL 320)
(MAP NUMBER 3720198600K,
MAP REVISED DECEMBER 06, 2019)
REPAIR
DRAINFIELD
(NIC)
INITIAL
DRAINFIELD
SHEET TITLE
CE134A
SEE SHEET C600 FOR SELF-INSPECTION REQUIREMENTS.
THE FINANCIALLY RESPONSIBLE PERSON AND/OR HIS AGENT WILL BE PERFORMING
SELF INSPECTIONS OF THE EROSION AND SEDIMENTATION CONTROL MEASURES USING
NCDEMLR'S SELF INSPECTION REPORT (WORKSHEET) AND THIS WILL BE KEPT
ONSITE.
SELF-INSPECTION RULES
LD
EROSION CONTROL LEGEND
SILT FENCE
LIMITS OF DISTURBANCE
SF
SILT FENCE OUTLET
CONSTRUCTION ENTRANCE
SHEET TITLE
SHEET NUMBER
SHEET ISSUE
SCO ID NO.
KHA PROJECT NO.
KERR LAKE STATE
RECREATIONAL
AREA
IMPROVEMENTS
NO. DATEDESCRIPTION
24-27518-01A t2307
6254 SATTERWHITE
POINT ROAD
NV5 ENGINEERS AND CONSULTANTS, INC.
3300 REGENCY PARKWAY, SUITE 100
CARY, NC 27518
P: 919.851.1912 www.NV5.com NC License # F-1333
CD PRICING SET 01/23/26
08/22/25 06/14/24
DESIGN DEVELOPMENT
SCHEMATIC DESIGN
CONSTRUCTION DOCUMENTS 02/04/264
5 05/08/26CD - SCO FINAL REVIEW
6 07/01/26BID DOCUMENTS
SCALE: 1" = 20'-0"1 EROSION CONTROL PLAN - SATTERWHITE POINT
SEE SHEET C600 EROSION CONTROL
CONSTRUCTION SEQUENCE.
SEE SHEET C600 FOR ADDITIONAL EROSION
CONTROL NOTES.
DISTURBED AREA = 2.34 AC. (TOTAL FOR SATTERWHITE POINT)
1. DURING ALL PHASES OF CONSTRUCTION, GROUNDCOVER ON EXPOSED SLOPES
SHALL BE PROVIDED ACCORDING TO GROUND STABILIZATION TABLE (SHEET
C600) FOLLOWING COMPLETION OF ANY PHASE OF GRADING.
2. FINAL PERMANENT GROUNDCOVER FOR ALL DISTURBED AREAS SHALL BE
PROVIDED ON ALL DISTURBED AREAS ACCORDING TO GROUND STABILIZATION
TABLE (SHEET C600) FOLLOWING COMPLETION OF CONSTRUCTION OR
DEVELOPMENT.
3. THE ABOVE REQUIREMENTS ARE THE MINIMUM NECESSARY TO MEET EROSION
AND SEDIMENT CONTROL REGULATIONS.
4. SLOPE EROSION CONTROL MATTING SHALL BE INSTALLED FOR TEMPORARY
STABILIZATION DURING THE ESTABLISHMENT OF VEGETATIVE COVER ON ALL
STEEP SLOPES (6:1 OR STEEPER). NO SYNTHETIC, PLASTIC OR NYLON MATERIALS
MAY BE USED. MATTING MUST BE 100% NATURAL FIBER, SUCH AS A COIR.REFER
TO MATERIAL SPECIFICATIONS. INSTALL MATTING PER MANUFACTURER'S
INSTRUCTIONS.
5. ALL OTHER SEEDED AREAS SHALL BE MULCHED WITH STRAW AND TACKED WITH
CELLULOSE HYDROMULCH, WOOD FIBER HDYDROMULCH OR ENHANCED WOOD
FIBER HUDROMULCH. ASPHALT IS NOT ALLOWED AS A TACKING AGENT ON DPR
PROJECTS.MALACHITE GREEN DYE OR OTHER DYE DERIVATIVES ARE ALSO NOT
ALLOWED DURING HYDROSEEDING/HYDROMULCHING OPERATIONS.
GROUND STABILIZATION SHALL BE PROVIDED ON ALL DISTURBED AREAS ACCORDING
TO GROUND STABILIZATION NOTES. SEE SHEET C600.
EXTENSIONS OF TIME MAY BE APPROVED BY THE PERMITTING AUTHORITY BASED ON
WEATHER OR OTHER SITE-SPECIFIC CONDITIONS THAT MAKE COMPLIANCE
IMPRACTICABLE (SECTION II.B(2) (b))
THE REQUIREMENTS ON SHEET C600 ARE THE MINIMUM NECESSARY TO MEET
EROSION AND SEDIMENT CONTROL REGULATIONS.
INSTALL TEMPORARY MATTING FOR STABILIZATION DURING THE ESTABLISHMENT OF
VEGETATIVE COVER ON ALL STEEP SLOPES (6:1 OR STEEPER) AND AREAS OF
CONCENTRATED FLOW (CHANNELS, DITCHES, SWALES, ETC.). NO SYNTHETIC,
PLASTIC OR NYLON MATERIALS MAY BE USED. MATTING MUST BE 100% NATURAL
FIBER, SUCH AS A COIR. REFER TO SPECIFICATION SECTION 312500 FOR MATERIAL
SPECIFICATIONS. INSTALL MATTING PER MANUFACTURER'S INSTRUCTIONS.
SLOPE & SURFACE STABILIZATION
MAINTENANCE PLAN
1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL NCDEQ STANDARDS,
SPECIFICATIONS AND DETAILS.
2. THE CONTRACTOR SHALL COMPLY WITH ALL STATE AND LOCAL CODES IN OBSERVING
EROSION CONTROL MEASURES BOTH ON AND OFF SITE.
3. THE CONTRACTOR SHALL MAINTAIN ALL EROSION CONTROL DEVICES AFTER EACH RAINFALL
EVENT OR AS DIRECTED BY LOCAL AUTHORITIES OR ARCHITECT.
4. ALL STORM DRAINAGE PIPES SHALL BE THOROUGHLY FLUSHED OF ALL SEDIMENT FOLLOWING
SITE STABILIZATION. INTERIOR FLUSHING OF SYSTEM SHALL BE PERFORMED AS NEEDED TO
MAINTAIN PROPER FUNCTIONING OF THE DRAINAGE SYSTEM. CLEANING SHALL BE
PERFORMED IN A MANNER WHICH PREVENTS SEDIMENT FROM BEING FLUSHED
THROUGH PIPES TO THE EXISTING DRAINAGE SYSTEM.
5. THE INDICATED STAGING AREA IS INTENDED FOR VEHICLES AND NON-ERODIBLE MATERIALS
ONLY. NO SOIL, SAND OR OTHER ERODIBLE, FINE GRAINED MATERIAL SHALL BE STORED
OUTSIDE OF THE LIMITS OF THE SITE PROTECTED BY SEDIMENT AND EROSION CONTROL
DEVICES AND MEASURES.
6. ANY DEWATERING OF SEDIMENT CONTAINMENT DEVICES FOR MAINTENANCE,
REMOVAL OR CONVERSION PURPOSES IS TO BE DONE THROUGH A SILT BAG.
7. ANY DEWATERING OF STORM/UTILITY TRENCHES IS TO BE DONE THROUGH A SILT
BAG.
8. CONTRACTOR SHALL USE TIRE WASH STATION OR OTHER MEANS TO PREVENT SEDIMENT
FROM TRACKING ONTO THE ROAD IF CONSTRUCTION ENTRANCE IS FOUND INSUFFICIENT AT
NO ADDITIONAL COST TO OWNER.
EROSION CONTROL NOTES
EROSION
CONTROL
PLAN -
SATTERWHITE
POINT
NOTE:
THE ENGINEER DOES NOT GUARANTEE THAT ALL EXISTING FACILITIES SUCH AS PIPELINES,
ELECTRICAL LINES, CONDUIT, TELEPHONE CABLE, SERVICE CONNECTIONS, OR OTHER FACILITIES ARE SHOWN ON THE PLANS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO HAVE ALL UTILITIES LOCATED BY THEIR RESPECTIVE OWNERS, FIELD MARK THE UTILITY LOCATIONS, AND PROTECT ALL SUCH EXISTING FACILITIES PRIOR TO BEGINNING CONSTRUCTION. THE CONTRACTOR IS FULLY
RESPONSIBLE FOR NOTIFYING ALL UTILITY OWNERS.
GRADING NOTE:
ELEVATIONS SHOWN ON THIS SHEET WERE PROVIDED BY SURFACE678. REFER TO L SHEETS FOR ADDITIONAL INFORMATION. BRING ANY DISCREPANCIES TO THE ENGINEER PRIOR TO ORDERING &
INSTALLATION OF EROSION CONTROL MEASURES SHOWN ON THIS SHEET.
7 08/12/26ADDENDUM 03
THIS SHEET HAS BEEN REVISED FOR CONSISTENCY
WITH BACKGROUND (MATERIALS) SHOWN ON SHEET L134A.
KHA
Image
KHA
Image
KHA
Line
KHA
Line
E
E
E
EEEEEEEE
E E
E E
E
E
FLOOD HAZARD AREA (PER GIS)
(ZONE AE; EL 320)
(MAP NUMBER 3720198600K,
MAP REVISED DECEMBER 06, 2019)
FLOOD HAZARD AREA (PER GIS)
(ZONE AE; EL 320)
(MAP NUMBER 3720198600K,
MAP REVISED DECEMBER 06, 2019)
GT OWS
FM
FM
FM
FM
FM
FM FM FM FM FM FM FM
ST
PT
SP SP SP SP SPSS
SS
SS
SS
SS
SS
TIE TO EXIST. BLDG. SERVICE
CONTRACTOR TO VERIFY EXIST.
SERVICE PRIOR TO INSTALLATION
OF SEPTIC SYSTEM
4" PVC CLEANOUT
TOP: 322.10' (FLUSH W/ GRADE)
INVERT: TO BE FIELD
DETERMINED (MIN. 1% SLOPE)
4" PVC SANITARY
SEWER SERIVICE
TIE TO PROPOSED SEPTIC
SYSTEM (MIN. 2% SLOPE).
REFER TO SEPTIC NOTES.
SEPTIC TANK.
SEE SEPTIC NOTES.
PUMP TANK.
SEE SEPTIC NOTES
& ELECTRICAL.
MISC. SEWER PIPING
SEE SEPTIC NOTES.
GRIT TANK. SEE
SEPTIC NOTES.
OIL WATER
SEPARATOR.
SEE SEPTIC
NOTES.
4" PVC CLEANOUT
TOP: 325.00'
(FLUSH W/ STONE
OF UTILITY YARD)
INV.: 318.50'
4" PVC SANITARY
SEWER SERIVICE
SEE PLUMBING FOR
CONTINUATION.
4" PVC
CLEANOUT
TOP: 325.20'
(FLUSH W/ PVT)
INV.: 320.25'
4" PVC CLEANOUT
TOP: 325.00'
(FLUSH W/ STONE
OF UTILITY YARD)
INVERT: 320.10'
SEE PLUMBING FOR
CONTINUATION.
TIE TO PROPOSED SEPTIC
SYSTEM (MIN. 2% SLOPE).
REFER TO SEPTIC NOTES.
FORCEMAIN. SEE
SEPTIC NOTES.
MANIFOLD. SEE
SEPTIC NOTES.
2" PVC WATER
SERVICE
TIE TO EXIST. WATERLINE.
RE-CONNECT EXIST. HOSE BIBS AS NEEDED
TO EXTEND EXIST. 2-IN. WATERLINE
SEPTIC FIELD.
(SEE SEPTIC NOTES).
4" PVC SANITARY
SEWER SERIVICE
PT
UNDERGROUND
PROPANE TANK.
SEE PLUMBING.
AIR COMPRESSOR.
SEE PLUMBING.
FORCEMAIN. SEE
SEPTIC NOTES.
SLEEVED IN DIP OR
PIPING ENCASED IN
CONCRETE. SEE
SEPTIC NOTES.
SLEEVED IN DIP OR
PIPING ENCASED IN
CONCRETE. SEE
SEPTIC NOTES.
2" GATE VALVE
2" DOM. METER
2" BACKFLOW SEE
WATER NOTES.
W W
W
2" GATE VALVE
REPAIR
DRAINFIELD
(NIC)
INITIAL
DRAINFIELD
FM
FM
FM
FM FM FM
FORCEMAIN (REPAIR) (NIC).
REFER TO SEPTIC NOTES.
ELECTRICAL CONDUIT;
SEE ELECTRICAL.
SEE ELECTRICAL
FOR CONTINUATION.
MBF
NEW PAD MOUNTED
TRANSFORMER;
SEE ELECTRICAL.
CU134A
UTILITY LEGEND
WATER
PROPOSED
1. ALL SEPTIC RELATED ITEMS ARE SHOWN FOR REFERENCE PURPOSES ONLY. THIS
INCLUDES BUT NOT LIMITED TO TANKS, PUMPS, FORCEMAIN, MANIFOLD,
CONTROLS AND OTHER ASSOCIATED PIPING.
2. REFER TO PRESSURE MANIFOLD SYSTEM ENGINEERED OPTION PERMIT PLANS
TITLED ' KATHERINE HOGAN ARCHITECTS KERR LAKE STATE PARK (AUTO
MAINTENANCE BUILDING) PREPARED BY MACCONNELL & ASSOCIATES, P.C.
DATED 05/06/2026 OR LATEST VERSION FOR ADDITIONAL INFORMATION.
3. ALL REPAIR DRAINFIELD ITEMS (AREA 2, OR ZONE 2) ARE SHOWN FOR SCHEMATIC
PURPOSES ONLY AND NOT INCLUDED IN CONTRACT. THIS INCLUDES BUT NOT
LIMITED TO LEACH FIELD, FORECEMAIN, MANIFOLD AND OTHER OTHER RELATED
COMPONENTS. REFER TO SEPTIC DRAWINGS FOR CLARIFICATION.
4. REFER TO ELECTRICAL DRAWINGS FOR POWER REQUIREMENTS.
SEPTIC (SATTERWHITE POINT) NOTES
SHEET TITLE
SHEET NUMBER
SHEET ISSUE
SCO ID NO.
KHA PROJECT NO.
KERR LAKE STATE
RECREATIONAL
AREA
IMPROVEMENTS
NO. DATEDESCRIPTION
24-27518-01A t2307
6254 SATTERWHITE
POINT ROAD
NV5 ENGINEERS AND CONSULTANTS, INC.
3300 REGENCY PARKWAY, SUITE 100
CARY, NC 27518
P: 919.851.1912 www.NV5.com NC License # F-1333
CD PRICING SET 01/23/26
08/22/25 06/14/24
DESIGN DEVELOPMENT
SCHEMATIC DESIGN
CONSTRUCTION DOCUMENTS 02/04/264
5 05/08/26CD - SCO FINAL REVIEW
6 07/01/26BID DOCUMENTS
SANITARY SEWER SERVICE
FORCEMAIN (BY OTHERS)
SCALE: 1" = 20'-0"1 UTILITY PLAN - SATTERWHITE POINT
1. VERIFY EXISTING CONDITIONS AND CONNECTIONS TO EXISTING UTILITIES PRIOR TO
CONSTRUCTION. CONTRACTOR MAY NEED TO COORDINATE WITH NC STATE PARKS TO DETERMINE
LOCATION OF EXISTING UTILITIES DUE TO FIELD CONDITIONS. NOTIFY ENGINEER IF ANY
DISCREPANCIES ARE DISCOVERED.
2. DOMESTIC BACKFLOW TO BE FEBCO LF860 OR APPROVED EQUAL WITHIN HEATED ENCLOSURE.
REFER TO ELECTRICAL DRAWINGS FOR POWER REQUIREMENTS. CONTRACTOR TO PROVIDE SHOP
DRAWING FOR APPROVAL PRIOR TO ORDERING AND INSTALLATION.
WATER SERVICE NOTES
UTILITY PLAN -
SATTERWHITE
POINT
NOTE:
THE ENGINEER DOES NOT GUARANTEE THAT ALL EXISTING FACILITIES SUCH AS PIPELINES,
ELECTRICAL LINES, CONDUIT, TELEPHONE CABLE, SERVICE CONNECTIONS, OR OTHER FACILITIES ARE SHOWN ON THE PLANS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO HAVE ALL UTILITIES LOCATED BY THEIR RESPECTIVE OWNERS, FIELD MARK THE UTILITY LOCATIONS, AND PROTECT ALL SUCH EXISTING FACILITIES PRIOR TO BEGINNING CONSTRUCTION. THE CONTRACTOR IS FULLY
RESPONSIBLE FOR NOTIFYING ALL UTILITY OWNERS.
GRADING NOTE:
ELEVATIONS SHOWN ON THIS SHEET WERE PROVIDED BY SURFACE678. REFER TO L SHEETS FOR ADDITIONAL INFORMATION. BRING ANY DISCREPANCIES TO THE ENGINEER PRIOR TO ORDERING &
INSTALLATION OF UTILITY ITEMS SHOWN ON THIS SHEET.
1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL NCDENR STANDARDS,
SPECIFICATIONS AND DETAILS.
2. WATER LINE AND WATER SERVICES TO BE INSTALLED WITH A COVER OF NO LESS
THAN 3-FT TO FINISH GRADE WITH TRACER WIRE IN ACCORDANCE WITH 2018
NCPC 306.2.4 FOR PLASTIC PIPE.
3. SANITARY SEWER SERVICES TO BE INSTALLED WITH A COVER OF NO LESS THAN
3-FT TO FINISH GRADE IN NON-TRAFFIC AREAS, 4-FT TO FINISH GRADE IN
TRAFFIC AREAS IN ACCORDANCE WITH 2018 NCPC 306.2.4 FOR PLASTIC PIPE.
4. ALL UTILITIES TO BE INSTALLED WITH THE REQUIRED CLEARANCES AS INDICATED
IN THE DRAWINGS AND SPECIFICATIONS.
5. WATERLINES AND SEWER LINES SHALL BE INSTALLED WITH A MINIMUM
HORIZONTAL CLEARANCE OF 10-FT.
6. SEWER LINES SHALL BE INSTALLED WITH A MINIMUM VERTICAL CLEARANCE OF
24-IN TO STORM DRAINAGE PIPES. THIS INCLUDES ALL SUB-DRAINAGE PIPES.
7. COORDINATE AND SCHEDULE INSTALLATION OF ALL UTILITIES WITH OTHER PRIME
CONTRACTORS, UTILITY COMPANIES AND OTHER TRADES INCLUDING BUT NOT
LIMITED TO: NATURAL GAS, ELECTRICITY, TELEPHONE AND CATV.
8. VERIFY EXISTING CONDITIONS AND CONNECTIONS TO EXISTING UTILITIES PRIOR
TO CONSTRUCTION. NOTIFY ARCHITECT IF ANY DISCREPANCIES ARE
DISCOVERED.
9. CONTRACTOR IS RESPONSIBLE FOR ALL DAMAGES DURING CONSTRUCTION AND
SHALL MAKE REPAIRS AT NO EXPENSE TO THE OWNER.
10. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE NC STATE BUILDING
CODE AND OSHA REQUIREMENTS.
11. THE CONTRACTOR SHALL PROVIDE AN AS-BUILT SURVEY OF ALL UTILITY AND
STORM DRAINAGE IMPROVEMENTS FOLLOWING CONSTRUCTION.
12. CONTRACTOR SHALL PHASE DEMOLITION AND NEW CONSTRUCTION TO ENSURE
UNINTERRUPTED ACCESS AND UTILITY SERVICE TO ADJACENT FACILITIES.
COORDINATE SHORT-TERM, OFF-HOUR, TEMPORARY SHUT- DOWNS WITH THE
OWNER.
13. SEE GENERAL NOTES ON EXISTING CONDITIONS AND DEMOLITION PLAN FOR
REQUIREMENTS FOR REMOVAL AND PATCHING OF PAVEMENT FOR UTILITY
INSTALLATION.
14. ALL SANITARY SEWER SERVICES SHALL BE 4" PVC (SCH 40) @1.04% MIN. SLOPE
UNLESS INDICATED OTHERWISE. USE DUCTILE IRON WHEN COVER IS LESS THAN
24-IN.
15. NO WORK SHALL BE PERFORMED ON RIGHT-OF-WAYS OR ADJACENT PROPERTIES
UNTIL THE OWNER NOTIFIES CONTRACTOR IN WRITING OF PROCUREMENT OF
APPROPRIATE PERMITS, EASEMENTS, AGREEMENTS, OR RIGHTS-OF-WAY.
16. CONTRACTOR TO FIELD ADJUST PROPOSED SERVICES (WATER & SERVICE) AS
NECESSARY TO RETROFIT EXISTING SITE FEATURES. BRING ANY DISCREPANCIES
TO THE ENGINEER PRIOR TO CONSTRUCTION.
17. SEE SHEET C502 FOR ENLARGED PLAN OF SERVICE CONNECTIONS.
UTILITY NOTES
7 08/12/26ADDENDUM 037
THIS SHEET HAS BEEN REVISED FOR CONSISTENCY
WITH BACKGROUND (MATERIALS) SHOWN ON SHEET L134A.
KHA
Image
KHA
Image
KHA
Line
KHA
Line
GENERAL NOTES
A.
B.
C.
THE CONSTRUCTION SUBSYSTEMS AND PARTITION TYPES SHOWN,
INDICATE THE GENERAL CONSTRUCTION FEATURES OF THE
MAJORITY OF THE CONSTRUCTION SYSTEMS TO BE PROVIDED.
THEY ARE NOT INTENDED TO REPRESENT A COMPLETE LISTING OF
SYSTEMS REQUIRED AND DO NOT NECESSARILY INDICATE ALL IF
THE CONSTRUCTION REQUIREMENTS TO BE PROVIDED BY THE
CONTRACT DOCUMENTS
SEE REFLECTED CEILING PLANS FOR ADDITIONAL REQUIREMENTS
FOR PARTITION TYPES
REFERENCE FOR FIRE RESISTANCE & SOUND RATINGS
CCMA: CAROLINAS CONCRETE MASONRY ASSOCIATION,
CONCRETE MASONRY HANDBOOK, SOUND
CONTROL
GA: GYPSUM ASSOCIATION, FIRE RESISTANCE DESIGN
MANUAL, ELEVENTH EDITION
NCMA: NATIONAL CONCRETE MASONRY ASSOCIATION, TEK
NOTES
SA: SHINER AND ASSOCIATES
SBCC: STANDARD BUILDING CODE CONGRESS, LATEST
EDITION
UL: UNDERWRITERS LABORATORY, INC, FIRE
RESISTANCE DIRECTORY
D. WHERE FURRED/SINGLE FACED SYSTEMS OCCUR ON CONCRETE
MASONRY UNIT WALL OR PARTITION SURFACE, PROVIDE GYPSUM
BOARD TO 8" ABOVE CEILING, OR IF NO CEILING OCCURS, PROVIDE
GYPSUM BOARD TO UNDERSIDE OF DECK.
NOTES
PARTITION DESIGNATION KEY
1.
2.
3.
4.
5.
CONCRETE MASONRY UNIT WALLS AND PARTITIONS: PROVIDE
HORIZONTAL JOINT REINFORCEMENT, VERTICAL REINFORCEMENT,
BOND BEAMS, GROUTING, AND ADDITIONAL REQUIREMENTS AS
INDICATED BY STRUCTURAL DRAWINGS AND SPECIFICATIONS.
KEEP CAVITY CLEAR OF ALL MORTAR
SEE FINISH SCHEDULE FOR LOCATION OF APPLIED FINISHES (SUCH
AS CERAMIC TILE, WALL COVERING, ETC.) THAT MAY AFFECT THE
PARTITION SURFACE AND CONSTRUCTION REQUIREMENTS
WHERE CERAMIC TILE AND CEMENTITIOUS BACKER UNIT ARE NOT
SCHEDULED TO BE FULL HEIGHT OF PARTITION, PROVIDE GYPSUM
BOARD (TYPE X @ RATED PARTITIONS) AT THOSE PORTIONS OF
THE PARTITION NOT SCHEDULED TO RECEIVE CERAMIC TILE.
CEMENTITIOUS BACKER UNIT TO BE SAME THICKNESS AS GYPSUM
BOARD
PROVIDE ACOUSTICAL SEALANT AT PERIMETER OF ALL SOUND
RATED PARTITIONS AND AT ALL PARTITION PENETRATIONS. IF
PARTITION IS FIRE RATED, PROVIDE UL LABELED FIRESTOPPING IN
PLACE OF ACOUSTICAL SEALANT. AT PARTITIONS THAT ARE SOUND
AND FIRE RATED, PROVIDE ACOUSTICAL SEALANT AT PARTITION
PENETRATIONS THAT DO NOT REQUIRE FIRESTOPPING (EXAMPLE:
DUCT PENETRATIONS WITH FIRE DAMPERS).
A3N0
PARTITION CATEGORY
PARTITION SIZE
PARTITION INSULATION
PARTITION RATING
PARTITION CATEGORY
A - METAL STUD
F - FURRING
M - MASONRY
PARTITION SIZE
PARTITION INSULATION
N - NON-INSULATED
PARTITION INSULATION
0 - NON-RATED TO 8" ABOVE CEILING, UNO
1 - 1 HOUR FIRE PARTITION
2 - 2 HOUR FIRE PARTITION
3 - 3 HOUR FIRE PARTITION
4 - 4 HOUR FIRE PARTITION
S - SMOKE PARTITION
T - TILE SUBSTRATE PARTITION
X - NON-RATED TO DECK, SEALED TOP &
BOTTOM
Y - STRUCTURE TO DECK, FIN MATL TO 4"
ABOVE CLG
7/8"
FURRING
CHANNEL
1 5/8"
METAL
STUD
2 1/2"
METAL
STUD
3 5/8"
METAL
STUD
4"
METAL
STUD
8"
METAL
STUD
2 1/2" C-H
STUD
6"
METAL
STUD
7"
METAL
STUD
4" NOM.
CMU
6" NOM.
CMU
8" NOM.
CMU
12" NOM.
CMU
M8N0
FIRE RATING UL TEST NO. STC RATING: --
N/AN/AN/A
CONCRETE SLAB ON GRADE
HORIZ. JT REINFORCING
16" OC U.N.O.
SEE STRUCTURAL FOR
ADDITIONAL
INFORMATION ON VERT.
REINFORCING BARS
REF. STRUCTURAL FOR
LOCATIONS
OF BOND BEAMS, IF
APPLICABLE
7 3/4"
M8N0-1
FIRE RATING UL TEST NO. STC RATING: --
N/AN/AN/A
CONCRETE SLAB ON GRADE
HORIZ. JT REINFORCING
16" OC U.N.O.
SEE STRUCTURAL FOR
ADDITIONAL
INFORMATION ON VERT.
REINFORCING BARS
REF. STRUCTURAL FOR
LOCATIONS
OF BOND BEAMS, IF
APPLICABLE
WOOD STUD PARTITION
ABOVE CMU TO ROOF
FINISH WITH GYPSUM
WALL BOARD PNT-0
8' - 0"
H
EI
G H T
VA
R
IE
S
STANDING SEAM ROOF
PANEL
STANDING SEAM METAL ROOF R2
METAL ROOF PANEL,
SEAMED JOINT
STANDING SEAM METAL ROOF ON WOOD JOISTR1
UNDERLAYMENT
1/2" SUBSTRATE BOARD
ROOF JOIST (SEE
STRUCTURAL DRAWINGS
SPRAY FOAM INSULATION
PANEL CLIP
Z-PURLIN
UNFACED FIBERGLASS
INSULATION (R-30 TOTAL)
THERMAL SPACER
LONG TAB LAP LOCATION
CONTINUOUS VINYL FACING
STRUCTURAL CONCRETE
COMPACTED GRAVEL
EARTH
AIR BARRIER
TYPICAL SLAB ON GRADE CONSTRUCTIONS1
REINFORCING STEEL
RIGID INSULATION (MIN R-10
FOR 24" AT ALL PERIMETER
LOCATIONS
FIBER CEMENT / CMU WALL CONSTRUCTIONW1
5/16" FIBER CEMENT VERTICAL SIDING
2" POLYSTYRENE RIGID INSULATION
(R10ci) BETWEEN FURRING STRIPS
FLUID APPLIED AIR BARRIER
8" CMU
0' - 7 3/4"
0' - 11 3/4"
FIBER CEMENT LAP SIDING / WOOD STUD CAVITY
WALL CONSTRUCTION
5/8" PLYWOOD SHEATHING
2X6 WOOD STUD
1 LAYER 5/8" GYPSUM WALLBOARD
5/16" FIBER CEMENT VERTICAL SIDING
FLUID APPLIED AIR BARRIER
W2
TILE PER ELEVATIONS AND
FINISH SCHEDULE
5/8" PLYWOOD SHEATHING
11 3/4"
9 1/2"
3/4" FIBER CEMENT BATTEN
3/4" FIBER CEMENT BATTEN
FURRING STRIP EVERY 16" O.C.
FURRING STRIP
1 1/2"1 1/2"
METAL PANEL SIDING - MAINTENANCE BUILDING
CONTINUOUS VINYL FACING
W3
METAL PANEL SIDING PER MANUFACTURER
UNFACED FIBERGLASS
INSULATION (R-20 TOTAL)
GIRT
CLIP OR SCREW PER
MANUFACTURER REQUIREMENTS
BATT INSULATION
GYPSUM WALL BOARD
M6N0
FIRE RATING UL TEST NO. STC RATING: --
N/AN/AN/A
CONCRETE SLAB ON GRADE
HORIZ. JT REINFORCING
16" OC U.N.O.
SEE STRUCTURAL FOR
ADDITIONAL
INFORMATION ON VERT.
REINFORCING BARS
M4N0
FIRE RATING UL TEST NO. STC RATING: --
N/AN/AN/A
CONCRETE SLAB ON GRADE
HORIZ. JT REINFORCING
16" OC U.N.O.
SEE STRUCTURAL FOR
ADDITIONAL
INFORMATION ON VERT.
REINFORCING BARS
3 3/4"
5 3/4"
F3N0
FIRE RATING UL TEST NO. STC RATING: --
N/AN/AN/A
FURRING SUBSTRATE
(IF APPLICABLE)
CLIP TO FURRING SUBSTRATE
2x4 WOOD STUDS 16" O.C.
1 LAYER 5/8" GYPSUM WALLBOARD
BASE AS SCHEDULED
FLOOR FINISH AS SCHEDULED
CONCRETE SLAB ON GRADE
CERAMIC TILE - REFER TO
TYPE T0
A8S0
FIRE RATING UL TEST NO. STC RATING: 47
NGC 2386----
BACKER ROD & SEALANT
ROOF SUBSTRATE
2x8 WOOD STUDS 16" O.C.
1 LAYER 5/8" GYPSUM
WALLBOARD EACH SIDE
7 1/4"
T0
FIRE RATING UL TEST NO. STC RATING: NA
BACKER ROD & SEALANT
ROOF SUBSTRATE
WALL AS SCHEDULED
1 LAYER 5/8" GYPSUM
WALLBOARD EACH SIDE
CERAMIC TILE
8' - 0"
SHEET TITLE
SHEET NUMBER
SHEET ISSUE
SCO ID NO.
KHA PROJECT NO.
24-27518-01A
KERR LAKE
STATE
RECREATIONAL
AREA
IMPROVEMENTS
8/ /2 4:
:2
PM
08/13/26
A-00.01
SUBSYSTEMS &
PARTITION TYPES
6254 SATTERWHITE
POINT ROAD
t2307
CONSTRUCTION SUBSYSTEMS
PARTITION TYPES
FLOOR SYSTEMS
ROOF SYSTEMS
EXTERIOR WALL SYSTEMS
NO. DESCRIPTION DATE
1 SCHEMATIC DESIGN 06/14/24
2 DESIGN DEVELOPMENT 08/22/25
3 CD PRICING SET 01/23/26
4 CONSTRUCTION DOCUMENTS 02/04/26
5 CD - SCO FINAL REVIEW 05/08/26
6 BID DOCUMENTS 07/01/26
7 ADDENDUM 02 08/05/26
8 ADDENDUM 03 08/12/26
9 ADDENDUM 04 08/13/26
DOOR SCHEDULE NOTES
A.
B.
C.
D.
E.
F.
G.
UNDERCUT DOORS AS REQUIRED BY FINAL FLOOR FINISH
PROVIDE SEALANT BETWEEN FRAME PERIMETERS AND
SURROUNDING WALL CONSTRUCTION UNLESS OTHERWISE
INDICATED.
PROVIDE SEALANT BETWEEN INTERIOR AND EXTERIOR
STOREFRONT FRAME PERIMETERS AND SURROUNDING WALL
CONSTRUCTION UNLESS OTHERWISE INDICATED
GROUT FULL DOOR FRAMES IN MASONRY WALL CONSTRUCTION
REFER TO PROJECT MANUAL DIVISION 8 FOR HARDWARE
SCHEDULE
DOOR AND FRAME DETAILS INDICATE GENERAL CHARACTERISTICS
OF DOOR AND FRAME SIZES AND COMPONENTS AND MAY NOT
INDICATE EXACT FIELD CONDITIONS OR REQUIREMENTS.
COORDINATE DETAILS WITH OTHER DRAWINGS AND SPECS TO
DETERMINE ALL COMPONENTS (E.G., SEALANTS, ANCHORS,
HARDWARE, LINTELS, CLIPS) REQUIRED FOR COMPLETE AND
FUNCTIONAL INSTALLATION.
DOOR SWINGS ON FLOOR PLANS TAKE PRECEDENCE OVER
SWINGS INDICATED ELSEWHERE (E.G., ELEVATIONS).
R
EF
D O
O R
S C
H
ED
U
LE
REF SCH
HM-1
0' - 2"
0'
2"
0' - 2"
R
EF
S C
H
ED
U
LE
REF SCH
F
FLUSH
KICK PLATE
LOUVER AS SCHEDULED1'
6"
2' - 0"
1' - 6" MIN
1' - 0" MIN
6"
UNLESS REQUIRED BY CODE
OR INDICATED OTHERWISE
WALL WHERE
OCCURS
WALL WHERE
OCCURS
FIBER CEMENT SIDING
PRESSURE TREATED WOOD
BLOCKING AT SIDING TERMINATION
5/8" PLYWOOD SHEATHING
2.5" RIGID INSULATION
TRANSITION AIR BARRIER TO
WRAP INTO ROUGH OPENING
BACKER ROD AND SEALANT AS
REQ'D.
METAL FLASHING TO COVER
SIDING TERMINATION
HOLLOW METAL FRAME
GROUTED SOLID
DOOR AS SCHEDULED
8" CMU BLOCK
AUTOMATIC DOOR CLOSER
AT DOOR HEAD
DOOR AS SCHEDULED
DOOR AS SCHEDULED
DOOR FRAME BEYOND
AS SCHEDULED
FINISH AS SCHEDULED
SIGNAGE NOTES
A.
B.
C.
ALL ADA SIGNAGE WITH BRAILLE AND TACTILE ELEMENTS
ARE TO BE INSTALLED ON THE LATCH SIDE OF THE ENTRY
DOOR TO THE IDENTIFYING ROOM. SEE TYP SIGN
MOUNTING DETAILS ON A-07.00 FOR ADDITIONAL
INFORMATION
REFER TO A-05.00 FOR TYPICAL ROOM IDENTIFICATION
SIGNAGE LOCATIONS.
ALL SIGNAGE INDICATED AT EXTERIOR DOORS TO BE
PROVIDED WITH EXTERIOR GRADE SIGNAGE
4'
0" M
IN
5'
0" M
AX
18"
EQ EQ
1' - 6"
EQ EQ
1' - 6"
EQ EQ
DOUBLE DOOR
SINGLE DOOR
6"
4" 2"M2
MECHANICAL
EQ
1"
EQ
503 1"
EQ
2"
6"
SIGN TYPE A SIGN TYPE B
6"
8"
TOILET
1/ 4"
1/ 2"
3/ 4"
1/ 2"
1/ 4"
1/
2"
SIGN TYPE C
6"
8"
MENS
1/ 4"
1/ 2"
3/ 4"
1/ 2"
1/ 4"
1/
2"
SIGN TYPE D1
6"
8"
WOMENS
1/ 4"
1/ 2"
3/ 4"
1/ 2"
1/ 4"
1/
2"
SIGN TYPE D2
HOLLOW METAL FRAME GROUTED
SOLID
8" CMU BOND BEAM, REFER TO
STRUCTURAL FOR DETAILS
METAL FLASHING
2.5" RIGID INSULATION
5/8" PLYWOOD SHEATHING
FIBER CEMENT VERTICAL LAP SIDING
SLOPE
EXTERIOR INTERIOR
HOLLOW METAL DOOR AS
SCHEDULED
HOLLOW METAL DOOR
FRAME BEYOND
WEATHER STRIP
ALUMINUM DOOR THRESHOLD SET
IN A FULL BED OF SEALANT
STAINLESS STEEL
FLASHING
BITUMINOUS
DAMPPROOFING
SHEET TITLE
SHEET NUMBER
SHEET ISSUE
SCO ID NO.
KHA PROJECT NO.
24-27518-01A
KERR LAKE
STATE
RECREATIONAL
AREA
IMPROVEMENTS
8/
/2
3:
:0
PM
08/13/26
A-05.00
DOOR SCHEDULE,
ELEVATIONS, AND
DETAILS
6254 SATTERWHITE
POINT ROAD
t2307
DOOR FRAME TYPES DOOR PANEL TYPES
DOOR SWING CLEARANCE
DOOR SCHEDULE
NUMBER
DOOR FRAME
SIGNAGE HDWR Description CommentsTYPE SIZE MATERIAL TYPE MATERIAL
300A F 3'-0" x 7'-0" x 1-3/4" HOLLOW METAL HM-1 HOLLOW METAL D1 B PT-2 ALT #4 300B F 3'-0" x 7'-0" x 1-3/4" HOLLOW METAL HM-1 HOLLOW METAL D1 B PT-2 ALT #4 300C F 2'-6" x 7'-0" x 1-3/4" HOLLOW METAL HM-1 HOLLOW METAL B "MECHANICAL" C PT-2 ALT #4 301A F 3'-0" x 7'-0" x 1-3/4" HOLLOW METAL HM-1 HOLLOW METAL D1 B PT-2 ALT #4 301B F 3'-0" x 7'-0" x 1-3/4" HOLLOW METAL HM-1 HOLLOW METAL D1 B PT-2 ALT #4 301C F 2'-6" x 7'-0" x 1-3/4" HOLLOW METAL HM-1 HOLLOW METAL B "MECHANICAL" C PT-2 ALT #4 302 F 3'-0" x 7'-0" x 1-3/4" HOLLOW METAL HM-1 HOLLOW METAL C A PT-2 LOUVER IN DOOR, ALT #4 303 F 3'-0" x 7'-0" x 1-3/4" HOLLOW METAL HM-1 HOLLOW METAL C A PT-2 LOUVER IN DOOR, ALT #4 304 F 3'-0" x 7'-0" x 1-3/4" HOLLOW METAL HM-1 HOLLOW METAL B "JANITOR" C PT-2 LOUVER IN DOOR, ALT #4 305 F 3'-0" x 7'-0" x 1-3/4" HOLLOW METAL HM-1 HOLLOW METAL B "ELECTRICAL" C PT-2 LOUVER IN DOOR, ALT #4 401 F 3'-0" x 7'-0" x 1-3/4" HOLLOW METAL HM-1 HOLLOW METAL D1 B PT-2 ALT #4 402 F 3'-0" x 7'-0" x 1-3/4" HOLLOW METAL HM-1 HOLLOW METAL D1 B PT-2 ALT #4 403 F 3'-0" x 7'-0" x 1-3/4" HOLLOW METAL HM-1 HOLLOW METAL C A PT-2 LOUVER IN DOOR, ALT #4 404 F 3'-0" x 7'-0" x 1-3/4" HOLLOW METAL HM-1 HOLLOW METAL B "JANITOR" C PT-2 LOUVER IN DOOR, ALT #4 405 F 2'-6" x 7'-0" x 1-3/4" HOLLOW METAL HM-1 HOLLOW METAL B "MECHANICAL" C PT-2 ALT #4 500 F 3'-0" x 7'-0" x 1-3/4" HOLLOW METAL HM-1 HOLLOW METAL A E PT-2 ALT #4 500A F 3'-0" x 7'-0" x 1-3/4" HOLLOW METAL HM-1 HOLLOW METAL A E PT-2 ALT #4 501 F 3'-0" x 7'-0" x 1-3/4" HOLLOW METAL HM-1 HOLLOW METAL A D PT-2 ALT #4 502 F 3'-0" x 7'-0" x 1-3/4" HOLLOW METAL HM-1 HOLLOW METAL C A PT-2 ALT #4 503 F 3'-0" x 7'-0" x 1-3/4" HOLLOW METAL HM-1 HOLLOW METAL B "MECHANICAL" C PT-2 ALT #4 504 72" x 84" HOLLOW METAL HM-1 HOLLOW METAL B "STORAGE" C PT-2 ALT #4 505 10' x 10' ROLLING OVERHEAD COILING DOOR, REFER TO
SPECS
506 10' x 10' ROLLING OVERHEAD COILING DOOR, REFER TO
SPECS
507 10' x 10' ROLLING OVERHEAD COILING DOOR, REFER TO
SPECS
508 10' x 10' ROLLING OVERHEAD COILING DOOR, REFER TO
SPECS
3" = 1'-0"
TYP. EXTERIOR HOLLOW METAL JAMB6 DOOR CLOSER DETAIL
3" = 1'-0"
TYP. INTERIOR HOLLOW METAL DOOR THRESHOLD2
SIGN MOUNTING DETAILS
6" = 1'-0"
SIGN TYPES5
F
3" = 1'-0"
TYP. HOLLOW METAL HEAD DETAIL4
3" = 1'-0"
TYP. EXTERIOR DOOR THRESHOLD7
NO. DESCRIPTION DATE
1 SCHEMATIC DESIGN 06/14/24
2 DESIGN DEVELOPMENT 08/22/25
3 CD PRICING SET 01/23/26
4 CONSTRUCTION DOCUMENTS 02/04/26
5 CD - SCO FINAL REVIEW 05/08/26
6 BID DOCUMENTS 07/01/26
9 ADDENDUM 04 08/13/26
Image
| CE132-1 KERR LAKE NUTBUSH NORTH EROSION CONTROL PLAN_Addendum03 |
| CU132-1 KERR LAKE NUTBUSH NORTH UTILITY PLAN_Addendum03 |
| CE134A KERR LAKE SATTERWHITE PT EROSION CONTROL PLAN_Addendum03 |
| CU134A KERR LAKE SATTERWHITE PT UTILITY PLAN_Addendum03 |
| t2307_Kerr Lake_v24 |
| A-00.01 - SUBSYSTEMS & PARTITION TYPES |
| A-05.00 - DOOR SCHEDULE, ELEVATIONS, AND DETAILS |