Schedule J Typical 8 Workstation Cluster.pdf

PDF 510 KB Posted

Attached to
Modular Office Systems Furniture and Services
Solicitation number
RFP 171 210000001771 4
Issued by
Michigan

About this file

This is a furniture plan document from the State of Michigan, Department of Technology, Management and Budget (DTMB), Real Estate Division for a modular furniture RFP (RFP No. 210000001771). The document presents a detailed layout specification for a typical 8-workstation cluster configuration designed for state facilities located at 3111 W. St. Joseph St., Lansing, Michigan 48917. The plan establishes standardized workstation specifications including standing height work surfaces with various dimensions (ranging from 44" x 48" to 64" x 48"), powered panel configurations, and electrical requirements of 4 duplex outlets per station with 1 basefeed or topfeed per 4 stations.

The specifications require all components to be locking, all panels to be powered, and all panel and worksurface supports to meet manufacturer recommendations regarding run lengths and support type/quantity. Additional requirements include the installation of center cantilevers on worksurfaces 60 inches in length or longer, 2 shelf dividers per overhead storage unit, and open frame panels with fabric inserts when basefeeds are positioned against walls. The document includes architectural scale drawings (1/4" = 1'0") that provide visual representations of the workstation cluster layout and component placement, serving as a specification guide for furniture vendors responding to the state's modular furniture procurement initiative.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P/ B/ F

P/ B/ F

P/ B/ F

B/ F

F/ F

F/ F

B/B/F

F/ F/ F

F/ F/ F/ F / F

F/ F/ F/ F / F

"x

"x

"x

"x

"x

64"x48"

"x

64"x24"44"x48"

64"x24"

"x

64"x24"

"x

64"x48"

"x

64"x48"

"x

64"x48"

"x

64"x48"64"x24"

64"x24"

"x

64"x48"64"x30"

44"x48"

W . S

T.

J

O S E

PH

S

T

LA

N S I

N G

, M I

1/ 4"

'0

D ra w n

By

D at e :

Sh ee t:

Sc al e:

ST

AT

E O

F M

IC

H

IG

AN

T

YP

IC

AL

W O

R

KS

TA

T I

O N

S

Ph on e:

R

EA

L

ES

TA

T E

D

IV

IS

IO

N

M O

D U

L A R

R

FP

-F U

R N

IT

U

R E

PL

AN

Pr oj e c t #

4- 9-

C lie n t

N am e:

D

TM

B-

ST

AT

E

FA

C

IL

IT

IE

S

AD

M

IN

IS

T R

AT

IO

N

STANDING HEIGHT

SURFACE

-ALL PANEL CONFIGURATIONS AND WORKSURFACE SUPPORTS TO MEET MANUFACTURER RECOMMENDATIONS IN REGARDS TO RUN

LENGTHS AND TYPE/QUANTITY OF SUPPORTS FOR WORK SURFACES.

CURRENT STANDARDS:

-ALL PANELS TO BE POWERED

-1 BASEFEED/TOPFEED PER 4 STATIONS

-4 DUPLEX OUTLETS PER STATION

-2 SHELF DIVIDERS (1 PAIR) PER OVERHEAD STORAGE UNIT

-WHEN A BASEFEED IS PLACED IN WALL WITH PANELS TO BE AGAINST IT, AN OPEN FRAME PANEL IS REQUIRED WITH FABRIC INSERT

FROM WORKSURFACE LEVEL UP.

- ALL COMPONENTS TO BE LOCKING.

- CENTER CANTILEVER TO BE INSTALLED ON WORKSURFACES 60" IN LENGTH OR LONGER.

BASEFEED

OPEN FRAME PANEL

WITH FABRIC INSERT

TOPFEED

COLUMN

SCHEDULE J, TYPICAL 8 WORKSTATION CLUSTER

RFP NO. 210000001771

Sh ee t:

Ph on e:

N

TS

R

EA

L

ES

TA

T E

D

IV

IS

IO

N

4- 9-

C lie n t

N am e:

D at e :

D ra w n

By

D

TM

B-

ST

AT

E

FA

C

IL

IT

IE

S

AD

M

IN

IS

T R

AT

IO

N

W . S

T.

J

O S E

PH

S

T

LA

N S I

N G

, M I

Sc al e:

ST

AT

E O

F M

IC

H

IG

AN

T

YP

IC

AL

W O

R

KS

TA

T I

O N

S Pr oj e c t #

M O

D U

L A R

R

FP

-F U

R N

IT

U

R E

PL

AN

D at e :

D

TM

B-

ST

AT

E

FA

C

IL

IT

IE

S

AD

M

IN

IS

T R

AT

IO

N

D ra w n

By

M O

D U

L A R

R

FP

-F U

R N

IT

U

R E

PL

AN

ST

AT

E O

F M

IC

H

IG

AN

T

YP

IC

AL

W O

R

KS

TA

T I

O N

S Sh ee t:

N

TS

Pr oj e c t #

4- 9-

Sc al e:

C lie n t N am e:

R

EA

L

ES

TA

T E

D

IV

IS

IO

N

W . S

T.

J

O S E

PH

S

T

LA

N S I

N G

, M I

Ph on e:

File details come from the government source that posted it. Updated .