SCD_Waiver_-_Fire_Systems.pdf

PDF 933 KB Posted

Attached to
On Call Fire Sprinkler Inspection and Services
Solicitation number
2026-ITB-364
Issued by
New Haven County, Connecticut

About this file

This file is an email chain and scope of work document related to an on-call fire sprinkler inspection and repair services contract for the New Haven Public Schools in Connecticut. The services encompass furnishing all material, labor, supervision, tools, supplies, and expenses necessary to perform sprinkler inspections and repairs work orders issued by the New Haven Public Schools Facilities Department, including testing, inspection, preventive maintenance, repairs, and emergency services in compliance with NFPA 13, 20, and 25 standards. The contractor must provide weekly, monthly, quarterly, and annual inspection, testing, and maintenance services for all sprinkler systems (wet/dry, fire pumps, sprinkler heads, and standpipes), as well as address both wet-side and electrical aspects of fire alarm devices and fire alarm control panels. The contractor is required to perform five-year inspections and maintenance items, valve maintenance, monthly backflow prevention device inspections with flow and tamper switch testing, and prepare all necessary certifications and reports required by NFPA standards. Weekly inspections are required only for fire pumps, with other weekly inspections permitted to occur monthly per NFPA exceptions, provided proper safeguards are in place.

As of March 2025, the New Haven Public Schools indicated they had no registered vendors capable of providing these specialty fire alarm and sprinkler repair and maintenance services. No pricing terms, set-asides, contract award dates, or contract term details are specified in this file. The document serves as a scope of work and specification document to guide qualified contractors in understanding the requirements for this on-call services contract.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Barbarotta, Heather

From: Lilia Snyder <lsnyder@newhavenct.gov> Sent: Tuesday, May 19, 2026 3:16 PM To: Barbarotta, Heather Subject: RE: SCD-Sprinkler and Alarm Inspection and Repair Services

At this tine the SCD Program does not have registered vendors to perform Fire Alarm and Sprinkler Repairs and Maintenance.

Lil

From: Barbarotta, Heather <Heather.Barbarotta@new-haven.k12.ct.us> Sent: Tuesday, May 19, 2026 2:50 PM To: Lilia Snyder <lsnyder@newhavenct.gov> Subject: RE: SCD-Sprinkler and Alarm Inspection and Repair Services

Please be cautious This email originated from outside of the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe.

Hi Lil. Please confirm if you have a vendor for Fire Alarm and Sprinkler Maintenance and Repairs.

Thank you- Heather

From: Lilia Snyder <lsnyder@newhavenct.gov> Sent: Monday, March 31, 2025 11:06 AM To: Barbarotta, Heather <Heather.Barbarotta@new-haven.k12.ct.us> Subject: RE: SCD-Sprinkler Inspection and Repair Services

This is a specialty service and we currently do not have vebndors who can perform this service-

From: Barbarotta, Heather <Heather.Barbarotta@new-haven.k12.ct.us> Sent: Monday, March 31, 2025 10:00 AM To: Lilia Snyder <lsnyder@newhavenct.gov> Subject: SCD-Sprinkler Inspection and Repair Services

Please be cautious This email originated from outside of the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe.

Hi Lil. I didn’t see a vendor listed on your sheet that performs these services. Do you have any vendors that can perform these services districtwide?

Brief Scope of Services

1. The work to be performed by the On-Call Sprinkler Inspection and Repairs Services Contractor under these Specifications shall consist of furnishing all material, labor, supervision, tools, supplies and other expenses necessary to fulfill all the details of Sprinkler Inspections and repairs related work orders issued by the New Haven Public Schools Facilities Department, including but not limited to Testing, Inspection, Preventive Maintenance, Repairs and Emergency Services as per NFPA 13, 20 & 25. On call Repairs and emergency services of every descriptions, including but not limited to inspections, adjustments, testing and replacement of parts for all sprinkler systems (wet/dry/Fire pumps/Sprinkler heads & Stand pipes) and related equipment covered under this contract and the preparation/furnishing of certifications and reports as required by NFPA 13, 20 & 25 to the City of New Haven Public Schools and the New Haven Fire Department.

2. Utilizing the information at hand (paragraph 2, above) and referring to NFPA 13, 20 & 25, the qualified contractor shall provide all necessary weekly, monthly , quarterly and annual inspection testing, and maintenance service, -Five year inspection and maintenance items (such as obstruction investigation Table 2-1) will be done. Valve maintenance (table 2-1) will be done. These services will include, (as appropriate to the specified system) but not be limited to the services required by NFPA 13, 20 & 25as summarized in Tables 2-1 (Sprinkler Systems), 3.1 & 3.2 (Standpipe and Hose Systems), (Fire Service Mains), 4-2.1 and 5-5.1 and NFPA 13, 20 & 25 (Fire Pumps), 9-1 (Valves and Fire Department Connections). The services of the qualified contractor shall cover both the wet-side (sprinklers, standpipes, etc…) and electrical (fire alarm devices, FACP, etc.) aspects of the system. The Initial Inspection shall include the first inspection and maintenance for all items. In addition, the contractor will be required to inspect on a monthly basis the back flow prevention devices installed on Fire Service. This should be done in conjunction with testing flow and tamper switches.

3. Note that the contractor is required to perform all weekly, monthly, quarterly and 5 year inspections (exclusive of pipe interiors) that are required by NFPA 13, 20 & 25. However for purposed of this bid, the only weekly inspections/maintenance and testing that are required are those in connection with Fire Pumps – see Table 5-

5.1 the only other weekly inspections are to our knowledge, covered by exceptions that permit them to occur monthly. Thus, the Contactor is required to perform all of the weekly inspections, maintenance and testing monthly. If field conditions indicate that the proper safeguards are not in place to permit exercising and exception, the Contractors shall immediately notify the owner so that such safeguards can be implemented.

Heather Barbarotta Assistant Director Operations and Sustainability New Haven Public Schools

ABM | Education 475-220-1647 (Office) Heather.Barbarotta@abm.com | www.abm.com | LinkedIn

ABM. Building Value.

ABM’s Mission: MAKE A DIFFERENCE, EVERY PERSON, EVERY DAY!