SBU

Anti-Ram Barriers Approved by the Bureau of Diplomatic Security (DS) for U.S. Department of State (DOS) Overseas Applications – January 2015

1. This list is marked Sensitive But Unclassified (SBU) and is intended for use supporting DOS projects.

2. This list is not intended for use by other organizations as they may have requirements and applications that differ significantly from DOS needs. ASTM and PAS 68 barrier rating systems offer additional options for threat vehicles, impact speeds and penetration conditions.

3. Significant changes since the 2012 version of this document are removing barriers and manufacturers that are no longer commercially available and removing commercially available passive barriers. Listed below, in item 7, are performance equivalencies that can be used to employ commercially available passive barriers on DOS projects. The only passive barriers on this list are DOS/DS-non-proprietary designs; these are notional designs that still need to be adapted to specific site conditions and site requirements.

4. This list addresses a barrier’s ability to withstand test vehicle impact and to meet DOS physical security requirements. It does not represent an endorsement of a specific product or design. This list does not address a barrier’s suitability for a specific application nor compliance with specific design, fabrication, construction or operational requirements.

5. Impact ratings are speed measured in miles per hour (mph) at time of impact. The DOS impact vehicle is a medium-duty, diesel-powered truck. The three DOS ratings are:

• 50mph (formerly known as “K12” by DS, and currently known as “M50/P1” by ASTM),

• 40mph (formerly known as “K8” by DS, and currently known as “M40/P1” by ASTM), and

• 30mph (formerly known as “K4” by DS, and currently known as “M30/P1” by ASTM).

The dynamic penetration limit for the impact vehicle for all these ratings is always 1 meter (3 ft. 3 ½ in.).

6. The barriers on this list were approved in their “as tested” configuration and size. Untested modifications are not approved by DS. Changes to mechanical systems associated with barrier operation (i.e. hydraulic vs.

electromechanical actuators) do not affect the barriers impact resistance.

7. Proprietary passive barriers are approved for use at DOS facilities if they have been successfully tested in accordance with the appropriate ASTM, PAS-68, IWA or legacy DOS testing. Listed below are performance equivalencies.

30 mph applications:

DOS SD-STD-02.01, Revision A, March 2003 - K4

ASTM F 2656 -07 - M30/P1

PAS 68 - V (type of barrier) 7500[N3]/48/90:1/ (no limit on dispersion of major debris) PAS68-2013: (Type of barrier )V/7500[N3]/48/90:1/(no limit on dispersion of major debris) IAW 14-1:2013 - V (type of barrier) 7500[N3}48/90:1[P1}/ (no limit on dispersion of major debris) IWA 14-1:2013: (Type of Barrier) V/7200[N3C]/48/90:1 (Major debris recorded but not part of classification) IWA14-1: 2013 (Type of barrier) V/7200[N2B]/48/90:1 (Major debris recorded but not part of classification)-

SENSITIVE BUT UNCLASSIFIED (SBU)

i

40 mph applications:

DOS SD-STD-02.01, Revision A, March 2003 - K8

ASTM F 2656 -07 – M40/P1

PAS 68 - V (type of barrier) 7500[N3]/64/90:1/ (no limit on dispersion of major debris) PAS68-2013: (Type of barrier)V/7500[N3]/64/90:1/ (no limit on dispersion of major debris) IAW 14-1:2013 - V (type of barrier) 7500[N3}/64/90:1[P1}/ (no limit on dispersion of major debris) IWA 14-1:2013: (Type of Barrier) V/7200[N3C]/64/90:1 (Major debris recorded but not part of classification) IWA14-1: 2013 (Type of barrier) V/7200[N2B]/64/90:1 (Major debris recorded but not part of classification)-

50 mph applications:

DOS SD-STD-02.01, Revision A, March 2003 - K12

ASTM F 2656 -07 – M50/P1

PAS 68 - V (type of barrier) 7500[N3]/80/90:1/ (no limit on dispersion of major debris) PAS68-2013: (Type of barrier)V/7500[N3]/80/90:1/ (no limit on dispersion of major debris) IAW 14-1:2013 - V (type of barrier) 7500[N3]/80/90:1[P1}/ (no limit on dispersion of major debris) IWA 14-1:2013: (Type of Barrier) V/7200[N3C]/80/90:1 (Major debris recorded but not part of classification) IWA14-1: 2013 (Type of barrier) V/7200[N2B]/80/90:1 (Major debris recorded but not part of classification)-

8. Barriers on this list are sorted by barrier type (e.g. bollard, wedge), then by impact rating, starting with the lowest rating.

9. Design information for DS non-proprietary barriers is available at the DS/PSD/RD SharePoint site.

10. This list is an update from that released in October, 2014, and includes the following notable changes:

• Added the SBU sentence (bullet 1, sentence 1)

• Added a phrase about the DS designs being notional and thus needing to be adapted to site-specific conditions / requirements (bullet 3, last sentence)

• Changed the date on the front cover sheet; added page numbers to the bottom of the cover pages;

spelled out “Sensitive But Unclassified” in the footer

• Added the DS-32 wall

• Added the Delta HD 300 EM wedge barrier

• Added the AutoGate VPL-K8-Shield electric drop-arm

• Clarified that the Delta DSC 720 rising bollard on this list is the “DSC 720 – 1M” model, which is 1 meter tall

• Clarified the descriptions of the DS-41, DS-42, DS-43 and DS-44 picket fences

• Clarified via the barrier name that the DS-50 and DS-51 are knee walls

• Removed the one-post bolted SVAR barrier (DS-202)

• Removed the duplicate Delta DSC 207s from the list (it was inadvertently on the list twice)

11. For questions regarding this list, please contact:

• Mr. Bill McCarthy, DS/PSD/RD Branch Chief: McCarthyWD@state.gov,

• Or, contact Russ Norris, Perimeter Protection Program Manager: norrisrj@state.gov,

• Both at: U.S. Dept. of State Attn: DS/PSD/RD, Building SA-14 Floor 10

SENSITIVE BUT UNCLASSIFIED (SBU)

ii mailto:McCarthyWD@state.gov mailto:norrisrj@state.gov

BEAMS

Beams, Drop-Arm Style (Active) Barrier Name Barrier Rating (mph) Designer Description (Optional)

CRB-240 30 American Physical Security Group / APS

Drop bar, 12’ opening, 30” to bottom of bar, 10.5” x 6.5” aluminum beam with two 8x1” 4-ply nylon straps, foundation depth 40”, P-110 hydraulic pumping unit

DS-70 manual drop arm 30 Department of State / DOS Manual drop arm, 12’ opening, 56 ¼” deep RC bollards at ends, 1 ½” dia 6x19 steel cored cable in 6x6” hollow structural section, counterweights at operator end

RSS-3000 30 Robotic Security Systems Inc. /

RSS

VPL-K8-Shield 40 AutoGate Inc. / AGI K8-rated drop arm that can be used in conjunction with a gate

VPL-CB-24 50 AutoGate Inc. / AGI Drop arm, 36” to center of bar, foundation depth 63”

DSC 7000 50 Delta Scientific / DEL 6x6” steel tube drop arm with 12 foot clear opening, 33.87” high, foundation depth 3’

NMSB XII 50 Nasatka / NAS 18’ hydraulic drop arm, 35” high, foundation depth at each end 36 3/8”

Beams, Post and Beam Style (Passive) Barrier Name Barrier Rating (mph) Designer Description (Optional)

DS-45 50 Department of State / DOS Post-dual beam fence, no continuous foundation, 8’ 9” augered holes for posts 12” x 12” x ½” steel tube, holes back-filled with concrete (no rebar)

Beams, Rising Style (Active) Barrier Name Barrier Rating (mph) Designer Description (Optional)

BLS (9m) 30 Gunnebo Wego GmbH / GUN Hydraulic rising beam with 9m (30’) clear opening, foundation depth 44 / 83"

Patriot 50 ATG Access Inc / ATG Hydraulic rising beam, 36” to top, 12’ opening, foundation 14” midspan, with 54” footers at ends

BLS (6m) 50 Gunnebo Wego GmbH / GUN Hydraulic rising beam with 6m (20’) clear opening, foundation depth 44 / 63”

VSH 610 - 6m 50 Heintzmann Group GmbH / HZG Hydraulic rising beam with 6m (20’) clear opening, 27’ total width, 8x8” beam 36” above grade, each foundation depth 55”

VSH 610 - 8.2m 50 Heintzmann Group GmbH / HZG Hydraulic rising beam with 8.2m (27’) clear opening, 34.5’ total width, 8x8” beam 36” above grade, each foundation depth 55”

Permanent Arrestor 50 Pro Barrier Engineering LLC / PBE Surface mounted hydraulic operated beam, hinged operation like a wedge when raising beam

BOLLARDS

Bollards, Fixed Style (Passive) Barrier Name Barrier Rating (mph) Designer Description (Optional)

DS-25 30 Department of State / DOS 39” high, 8” diameter, 48” clear opening, RC foundation 30” x 30”; Options for 10” dia. to integrate w/ DS-22 perimeter

DS-201 30 Department of State / DOS 2-post shallow foundation (18") system which can be outfitted as a Streetscape Vehicular Anti-Ram (SVAR) bench

DS-24 (40 mph) 40 Department of State / DOS Bollards in 12” x 4” steel tubing encased in concrete, connected by 4” square box tubing, adjustable for grade changes, 58” on center, depth 20.6” Individual bollard encased for 40 mph, full foundation encasement in concrete for 50 mph

DS-205 40 Department of State / DOS 2-post shallow foundation (11") system which can be outfitted as a Streetscape Vehicular Anti-Ram (SVAR) bench

DS-22 50 Department of State / DOS Min. 3 bollard array, 48” clear opening, 39” high, depth 4’, 22R removable variant with embedded sleeve

DS-23 50 Department of State / DOS Min. 3 bollard array, 48” clear opening, 39” high, tilted 10 deg. off vertical in attack direction, depth 18”

DS-24 (50 mph) 50 Department of State / DOS Bollards in 12” x 4” steel tubing encased in concrete, connected by 4” square box tubing, adjustable for grade changes, 58” on center, depth 20.6” Individual bollard encased for 40 mph, full foundation encasement in concrete for 50 mph

DS-203 50 Department of State / DOS 2-post shallow foundation (18") system which can be outfitted as a Streetscape Vehicular Anti-Ram (SVAR) bench

DS-204 50 Department of State / DOS 3-post shallow foundation (18") system which can be outfitted as a Streetscape Vehicular Anti-Ram (SVAR) bus shelter or pedestrian waiting cover or bike rack

DS-206 50 Department of State / DOS 5-post shallow foundation (18") system which can be outfitted as a Streetscape Vehicular Anti-Ram (SVAR) bus shelter or pedestrian waiting cover or bike rack

DS-207 50 Department of State / DOS 2-post shallow foundation (18") system which can be outfitted as a Streetscape Vehicular Anti-Ram (SVAR) sign

DS-208 50 Department of State / DOS 5-post shallow foundation (18") system which can be outfitted as a Streetscape Vehicular Anti-Ram (SVAR) bus shelter or pedestrian waiting cover or bike rack

BOLLARDS

Bollards, Retractable Style (Active) Barrier Name Barrier Rating (mph) Designer Description (Optional)

DSC 800 30 Delta Scientific / DEL Min. 3 bollard array at 40” on center, 35” high, 4’ 3” deep, hydraulic

SP 275-900 30 Gunnebo Wego GmbH / GUN Single unit hydraulic bollard, height 36”, 6.1’ deep

Hard Post EP-354A ST-650 30 Koei Technologies / KOE Min. 2 all-electric 13.9” o.d. bollards at 36” o.c. (22.1” clear space), 25.6” high, 4’ 4” deep

Hard Post EP-354A ST-700 40 Koei Technologies / KOE

Xact Series XT-1208-RB (prev Eagle Series)

40 Ross Security Systems / ROS

Titan 50 ATG Access Inc / ATG Min. 3 bollard array at 32” on center, bollard 38” high, foundation depth 5.7’, hydraulic

PDT 1200 50 Calpipe Industries / CAL Min. 3 bollard array at 39” on center, 36” high (structural), 36” with décor and cap, depth 5’, hydraulic

Hard Post EP-354A 50 Koei Technologies / KOE Min. 4 all-electric bollards at 35” on center, 37.4” high, 5’ 2” deep

Model 400 50 National Intelligent Traffic Systems / NIT

Set of 3 hydraulic bollards at 36” on center, 36” high, 5.8’ deep

DSC 720 – 1M 50 Delta Scientific / DEL This system is 1M tall. The bollards feature a variety of power options

DS-22R 50 Department of State / DOS Steel pipe bollards were fabricated from 10.75" OD schedule 140 steel pipe, positioned in steel sleeves fabricated from 12.75" OD schedule 100 steel pipe. Each bollard was 84" in length and projected 40" above the concrete footing.

FENCES

Fences, All Styles (Passive) Barrier Name Barrier Rating (mph) Designer Description (Optional)

DS-41 Picket Fence 30 Department of State / DOS 9ft high anti-climb picket fence of 2x4x1/4” steel tubes; DS-41 has diagonal supports and does not have a top rail; 21" depth

DS-42 Picket Fence 30 Department of State / DOS 9ft high anti-climb picket fence of 2x4x1/4” steel tubes; DS-42 has a top rail and does not have diagonal supports; 21" depth

DS-40 50 Department of State / DOS Blast resistant picket fence, 10” dia. concrete filled pipes at 5’ spacing, ¾ x ¾” steel pickets at 6” on center, anchored top & bottom w/ 1” wire ropes, 11.75’ high, continuous 4’ deep foundation

DS-43 Picket Fence 50 Department of State / DOS 9ft high anti-climb picket fence of 2x4x1/4” steel tubes; DS-43 has diagonal supports and does not have a top rail; DS-44 does not; 21" depth

DS-44 Picket Fence 50 Department of State / DOS 9ft high anti-climb picket fence of 2x4x1/4” steel tubes; DS-44 has a top rail and does not have diagonal supports; 21" depth

GATES

Gates, All Style (Active) Barrier Name Barrier Rating (mph) Designer Description (Optional)

Model 400 (with fence), Model 400A beam only

30 B&B ARMR / BBA Cantilever sliding gate, 12’ opening, no ground track or wheels, hydraulic, electric or manual, model 400A is beam only, model 400 has metal skirt at and below beam, top portion is pickets with ¾” square steel tubes at 2.5” o.c.

Fortified Impact Gate System (FIGS) 30 Tymetal Corp. / TYM Sliding gate, 24’ opening, 8x8x3/8” beam with 1” wire rope looped, diagonal structural members, height 6’, RC foundation depths at ends 4’

CG-12 50 American Physical Security Group / APS

Cantilever sliding gate w/ reinforcing beam, 2 buttresses, gate panel, and guide buttresses, beam center 36” high, 12’ opening, gate height 8’ 2”

SG 1500CR High Impact Sliding Gate 50 Avon Barrier Inc. / ABI 6.2m wide, 2.2m high, 4m clear opening between two supporting columns extending 440mm into concrete slab; Electrically driven rack & pinion mechanism

Model 450 (with fence), Model 450A beam only

50 B&B ARMR / BBA Cantilever sliding gate, 12’ opening, no ground track or wheels, hydraulic, electric or manual, model 400A is beam only, model 400 height w/ fence is 108”

930 Vee Gate, Broughton Defender 50 Broughton Controls / BRC 4.23m (14’) opening width, projects forward 3.14m (10’), overall width 7.6 m (25’), foundation depth 2’, height above grade 2m (6.6’)

High Security Sliding Gate DSC 288 50 Delta Scientific / DEL Shallow foundation design; Clear Openings Range from 120 to 360 inches (10 Ft to 30 Feet, 3 M to 9.1 M); Hydraulic and electromechanical power options

TT280 50 Delta Scientific / DEL Sliding gate, motor driven rack & pinion, install length 15.6’, opening 12’, height 9.5’, foundation depth 5’

Cable gate 50 Gibraltar Materials / GBM Motorized sliding gate, 24’ opening, mounts in 2x4” steel tubing w/ three 1 3/8” cable, height 9’, top cable 45½” high, foundation depth 6’, total width 42’

LSST 1000 sliding gate 50 Gunnebo Wego GmbH / GUN Sliding gate, 7m (22.97 ft) clear width; 4 posts support gate, electric motor and chain guide to operate;

2 gate portions; Foundation 400 mm deep

Truck Stopper 50 Gunnebo Wego GmbH / GUN Sliding gate w/ 13.1’ opening, height 47.6”, foundation depth 12”

NMSB XX 50 Nasatka / NAS Sliding gate, 14’ opening, height 9’, all aluminum, on hydraulic roller system, end foundation depths 4’, manual with electric hydraulic option

Model IFG-14 50 Logical Decisions Inc. / LDI Interlocking steel beam gate, 4 W200 x 46 steel beams, height 3’ 6 ½” at posts, foundation depth 3’ 8”, opening 12’

Model 32503 Security Gate 50 Perimeter Security Products /

PRS

6’ 8” high, 4’ foundation depth, 13’ opening w/ square framing grid of steel tubing and diagonal braces at each end, made functional after test by 1 man w/o power tools or equip.

PLANTERS

Planters, All Styles (Passive) Barrier Name Barrier Rating (mph) Designer Description (Optional)

DS-60 (30 mph) 30 Department of State / DOS Cabled/pinned surface planter, reinforced concrete, 39” high, 8ft wide, 4ft depth front-to-back, three 2” steel pegs per planter embedded 18” (asphalt), 4’ (soil), planter connected w/ 4 cables (each 5/8”), spaced at max. of 39” for 30 mph, 18” for 40 mph, and abutted and bolted for 50 mph

DS-61 30 Department of State / DOS Same as DS-60 planter except height is extended 8" to maintain 1 meter above grade w/ embedding 8" below grade; conduits for cables and pegs are absent

DS-62 (30 mph) 30 Department of State / DOS Modular L-shaped reinforced concrete planter, 8” thick, surface mounted, no anchoring, 4’ high, filled w/ sand/soil; 30mph configuration is 4’ high x 4’ front-to-back; 50mph is 4’ high x 8’ front-to-back

DS-60 (40 mph) 40 Department of State / DOS Cabled/pinned surface planter, reinforced concrete, 39” high, 8ft wide, 4ft depth front-to-back, three 2” steel pegs per planter embedded 18” (asphalt), 4’ (soil), planter connected w/ 4 cables (each 5/8”), spaced at max. of 39” for 30 mph, 18” for 40 mph, and abutted and bolted for 50 mph

DS-60 (50 mph) 50 Department of State / DOS Cabled/pinned surface planter, reinforced concrete, 39” high, 8ft wide, 4ft depth front-to-back, three 2” steel pegs per planter embedded 18” (asphalt), 4’ (soil), planter connected w/ 4 cables (each 5/8”), spaced at max. of 39” for 30 mph, 18” for 40 mph, and abutted and bolted for 50 mph

DS-62 (50 mph) 50 Department of State / DOS Modular L-shaped reinforced concrete planter, 8” thick, surface mounted, no anchoring, 4’ high, filled w/ sand/soil; 30mph configuration is 4’ high x 4’ front-to-back; 50mph is 4’ high x 8’ front-to-back

DS-9 50 Department of State / DOS Reinforced concrete planters, 9’ wide, spaced 3’ apart, embedded 36”

WALLS

Walls, All Styles (Passive) Barrier Name Barrier Rating (mph) Designer Description (Optional)

DS-51 Knee Wall 30 Department of State / DOS Knee wall, reinforced concrete, 34” above grade, 12” thick, foundation total depth 18”

DS-Retaining-Wall-30 30 Department of State / DOS

DS-Retaining-Wall-40 40 Department of State / DOS

DS-30 50 Department of State / DOS Anti-ram/anti-climb reinforced concrete wall, 9’ high, 10” thick, foundation at 12” depth, 12” thick (total depth 24”)

DS-32 50 Department of State / DOS A narrow foundation anti-ram high-wall, 18 inches front to back below-grade, 43.5 inches below grade depth, 9 feet tall above grade, 10 inches wide (front to back) above grade

DS-50 Knee Wall 50 Department of State / DOS Knee wall, reinforced concrete, 39” high, 12” thick, foundation at 12” depth, 12” thick (total depth 24”)

DS-Retaining-Wall-50 50 Department of State / DOS

WEDGES

Wedges, All Styles (Active) Barrier Name Barrier Rating (mph) Designer Description (Optional)

DSC 1200 30 Delta Scientific / DEL Surface mounted electro-hydraulic wedge, height 35”, epoxied and bolted onto existing surface, 12’ opening, end buttresses, central hinged plate

RB650STHH-3000 Roadblocker 40 Bavak Security Group / BVS Wedge barrier w/ steel framing, electro-hydraulic drive, height 26”, foundation depth 34.5”, steel frame width 10’

SW-12 50 American Physical Security Group / APS

Hydraulic wedge, tested w/ std 8’ wide blade, height 41”, foundation depth 12”

Sentinel 50 ATG Access Inc / ATG 8’ wide hydraulic wedge, single hydraulic cylinder, height 38”, foundation depth 18”

Model RSB 78 50 Automatic Systems America Inc.

/ ASA

Hydraulic wedge w/o buttresses, height 40”, depth 36”

RB1000STHB-CR Roadblocker 50 Bavak Security Group / BVS Wedge barrier w/ steel framing, electro-mechanical w/ MOOG actuator, height 39 7/8”, 10’ wide, foundation depth 54.5”

DSC 2000 50 Delta Scientific / DEL Min. 3 hydraulic wedges, no buttresses, each has 1” thick steel plate supported by three 1" chains, height 36”, each 24” wide, foundation depth 11”

DSC 207s 50 Delta Scientific / DEL Blocking width = 109" (2.77m). Main foundation = 139" wide (3.53m) x 113" long (2.87m) x 34" deep (864mm)

DSC 501 50 Delta Scientific / DEL 1” steel plate, 9’ wide, height 39”, foundation depth 18”

EM HD 300 50 Delta Scientific / DEL This is the Model HD 300 EM Phalanx (TM) Barricade System; It has a 24 inch (610 mm) foundation.

Deployed barricade height is 1 M (39 inches). It has an independent electro-mechanical actuator and proprietary counterbalance system is installed in each barricade

DSP K12 Road Blocker 50 Gunnebo Wego GmbH / GUN Electro-hydraulic wedge, plate width 14’, 39.4” high, foundation depth 60”

K12 Wedge 50 Gunnebo Wego GmbH / GUN Hydraulic wedge w/ cylinders, plate width 13’, 47.2” high, underground housing, RC foundation, depth 15.7”; options include both open and closed face versions

K12 Wedge - CF 50 Gunnebo Wego GmbH / GUN Hydraulic wedge w/ “closed face safety skirt”, two electrically powered cylinders, plate 13’ wide, 40” high, underground housing, RC foundation, depth 15.7”

CR1200 Rising Blocker 50 Heald Limited / HEA Hydraulic wedge, 1.2 m (47”) high, 13.8’ wide, fully operational post-test after front panel removed

HT1-Raptor aka the Erector 50 Heald Limited / HEA Excavations are 1750mm wide x 2800mm long x 500mm deep; can be fitted to a 450mm depth; sits 435mm into ground

NMSB III D-E 8 ft Wedge 50 Nasatka / NAS 8' wedge barrier; the III D uses a Moog linear actuator

RSS-2000 50 Robotic Security Systems Inc. /

RSS

Electric wedge in shallow steel vault, height 37”, foundation depth 24”

Xact Series Wedge barrier XT-1000-W 50 Ross Security Systems / ROS Steel plate, 5/8”, welded to 4 x 6 x ½” steel tube plus 5 chains (1- ¼”), height 36”, foundation depth 18”

SW 1900 9 ft Wedge 50 Smith & Wesson / SWF 9' wedge barrier