Salient Characteristics.pdf

PDF 200 KB Posted

Attached to
79 RGS - Hangar Aircraft Frequency Converter Federal contract opportunity
Solicitation number
FA487725QA539
Issued by
Department of the Air Force Air Combat Command

About this file

This document is a Salient Characteristics document for a Hard-wired Aircraft Power Panel, detailing specific technical requirements for a power panel to be delivered to the 79th RGS. The electrical requirements specify a three-phase input of 380-480V at 50/60 Hz with a full load input current of 93A, and an output of 115V L-N / 200V L-L at 400 Hz. Key features include a built-in maintenance diagnostic system, digital touch screen control panel, external USB communications port, internal step-up transformer, and input surge protection meeting IEEE C62.41 Category B standards.

The power panel comes with a one-year warranty and includes accessories such as a 60-foot AC output cable with an aircraft plug and safety interlock, and a floor or wall-mounted cable saddle or automatic reel. Additional requirements mandate installation and electrical connection services. The system is designed to be hard-wired into existing electrical infrastructure, with features like an AC output contactor with aircraft safety interlock, 5% maximum AC input current distortion, and an electronic operator and maintenance manual to support its operation and maintenance.

View the file

Other files for this federal contract opportunity

Other files attached to 79 RGS - Hangar Aircraft Frequency Converter, newest first.
File Type Posted
Combo - QA482 - Hangar Aircraft Frequency Converter.pdf PDF
Performance Work Statement.pdf PDF
Provisions and Clauses.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SALIENT CHARACTERISTICS

FOR

Hard-wired Aircraft Power Panel

1.0. SCOPE OF WORK:

All proposed products shall meet or exceed the following minimum specifications outlined in this Salient Characteristics. All items shall be delivered to the 79th RGS.

1.1. PRODUCT PERFORMANCE SPECIFICATION:

Item must meet the following minimum specifications:

SPECIFICATIONS

Headers Please adjust Headers to item requirement

Electrical Requirement:

Input: 380 to 480 V +10%/-15%, 3-phase, 50/60 Hz; full load input current 93 A (at 480 VAC)

Output: 115 V L-N / 200 V L-L, 3-phase, 4-wire, 400 Hz

Warranty: 1 Year

Features: Built-in maintenance diagnostic system

Digital touch screen control panel

External communications port access, front panel USB

208 to 480 V internal step up transformer

Input surge protection IAW IEEE C62.41, Category B

5% Max. AC input current distortion, IGBT active front end

AC output contactor “connect/disconnect” device with aircraft safety interlock

Electronic Operator and Maintenance Manual

Accessories: AC output cable, 60 feet, banded multiple conductors with aircraft plug and safety interlock

Floor or wall-mounted cable saddle or automatic reel

System is hard wired into existing electrical infrastructure

Additional Requirement:

Installation and electrical connection services provided