Salient Characteristics.pdf
PDF 200 KB Posted
- Attached to
- 79 RGS - Hangar Aircraft Frequency Converter Federal contract opportunity
- Solicitation number
- FA487725QA539
About this file
This document is a Salient Characteristics document for a Hard-wired Aircraft Power Panel, detailing specific technical requirements for a power panel to be delivered to the 79th RGS. The electrical requirements specify a three-phase input of 380-480V at 50/60 Hz with a full load input current of 93A, and an output of 115V L-N / 200V L-L at 400 Hz. Key features include a built-in maintenance diagnostic system, digital touch screen control panel, external USB communications port, internal step-up transformer, and input surge protection meeting IEEE C62.41 Category B standards.
The power panel comes with a one-year warranty and includes accessories such as a 60-foot AC output cable with an aircraft plug and safety interlock, and a floor or wall-mounted cable saddle or automatic reel. Additional requirements mandate installation and electrical connection services. The system is designed to be hard-wired into existing electrical infrastructure, with features like an AC output contactor with aircraft safety interlock, 5% maximum AC input current distortion, and an electronic operator and maintenance manual to support its operation and maintenance.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Combo - QA482 - Hangar Aircraft Frequency Converter.pdf | ||
| Performance Work Statement.pdf | ||
| Provisions and Clauses.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SALIENT CHARACTERISTICS
FOR
Hard-wired Aircraft Power Panel
1.0. SCOPE OF WORK:
All proposed products shall meet or exceed the following minimum specifications outlined in this Salient Characteristics. All items shall be delivered to the 79th RGS.
1.1. PRODUCT PERFORMANCE SPECIFICATION:
Item must meet the following minimum specifications:
SPECIFICATIONS
Headers Please adjust Headers to item requirement
Electrical Requirement:
Input: 380 to 480 V +10%/-15%, 3-phase, 50/60 Hz; full load input current 93 A (at 480 VAC)
Output: 115 V L-N / 200 V L-L, 3-phase, 4-wire, 400 Hz
Warranty: 1 Year
Features: Built-in maintenance diagnostic system
Digital touch screen control panel
External communications port access, front panel USB
208 to 480 V internal step up transformer
Input surge protection IAW IEEE C62.41, Category B
5% Max. AC input current distortion, IGBT active front end
AC output contactor “connect/disconnect” device with aircraft safety interlock
Electronic Operator and Maintenance Manual
Accessories: AC output cable, 60 feet, banded multiple conductors with aircraft plug and safety interlock
Floor or wall-mounted cable saddle or automatic reel
System is hard wired into existing electrical infrastructure
Additional Requirement:
Installation and electrical connection services provided
File details come from the government source that posted it. Updated .