SAF21-20-8FINAL.pdf
PDF 10 MB Posted
- Attached to
- Paseo Real Wastewater Reclamation Facility Chemical Feed, and Variable Frequency Drive (VFD) Replacements
- Solicitation number
- FY27-Const. ITB-007
- Issued by
- Santa Fe County, New Mexico
About this file
This is a design and engineering document prepared by Molzen Corbin for the City of Santa Fe, New Mexico, detailing mechanical, electrical, and control system replacements at the Paseo Real Wastewater Reclamation Facility. The project encompasses SCADA modifications, chemical feed system upgrades, and variable frequency drive (VFD) replacements across multiple facility buildings including the DAF Building, Mixed Liquor Pumps facility, UV Building, Headworks Building, NPW Building, and an offsite Reuse Building. The scope of work includes demolition of existing equipment such as gas-fired unit heaters, exhaust fans, louvers, and associated piping; installation of new motorized louvers with interlocked dampers, suspended unit heaters with electronic thermostats, and new exhaust fans with ductwork; electrical modifications including new circuits and connections for hypochlorite and polyaluminum chloride chemical tanks and pumps; and comprehensive control wiring schedules and SCADA integration across all treatment processes. The mechanical systems are designed with specific attention to roof penetrations, ductwork installation per SMACNA standards, equipment coordination with structural elements, and accessible thermostat placement at 48 to 60 inches above finished floor.
The engineering plans include detailed mechanical demolition and installation plans at 1/4-inch scale, electrical one-line diagrams with modifications, control wiring schedules with input/output tag lists across multiple sheets for each building, and specialized details for hypochlorite tank fill control panels and generator/ATS communication wiring. All ductwork is specified to be externally insulated with double-thick turning vanes on 90-degree elbows, and contractors are required to field-verify existing building conditions and louver sizes prior to ordering equipment. The design emphasizes coordination among mechanical, electrical, and structural trades to minimize conflicts and operational downtime, with contractors responsible for surface restoration and proper disposal of removed fixtures and piping as directed by the architect. The project documents reference both existing conditions to be preserved and new work requirements across treatment processes, chemical storage, and facility operations infrastructure.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2701 Miles Road SE A buquerque, New Mexico 87106
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
G000-002
PR
O
JE
C
T
IN
FO
M
R A
TI
O
N S
H
EE
T
2 41
Albuquerque, New Mexico 87106
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
G000-003
PR
O
JE
C
T
EQ
U
IP
M
EN
T A
N D
B U
IL
D
IN
G
L O
C A
TI
O
N S
3 41
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W
RF
S C
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y O
F
SA
N
TA
F E
SA
N
TA
F
E, N
M
02/10/2026
M
EC
H
AN
IC
AL
G
EN
ER
AL
N O
TE
S
LE
G
EN
D
M106-001
1. M106-001 MECHANICAL GENERAL NOTES & LEGEND
2. M106-101 MECHANICAL DEMOLITION PLAN
3. M106-102 MECHANICAL PLAN
4. M106-501 MECHANICAL DETAILS & SCHEDULES
MECHANICAL SHEET INDEX
A. ALL DUCTS SHALL BE EXTERNALLY INSULATED, UNLESS OTHERWISE NOTED.
B. ALL DUCT PENETRATIONS THROUGH THE ROOF SHALL BE CURBED, FLASHED, AND
COUNTER-FLASHED TO ACHIEVE A WATERTIGHT CONSTRUCTION.
C. COORDINATE ROOF PENETRATIONS TO AND FROM EQUIPMENT WITH STRUCTURAL
DRAWINGS. ROOF OPENINGS SHALL BE LOCATED BETWEEN JOISTS.
D. COORDINATE THE LOCATIONS OF ALL EQUIPMENT AND DUCTWORK WITH ANY
PLUMBING LINES AND ELECTRICAL CONDUIT.
E. ALL 90° SQUARE ELBOWS SHALL BE PROVIDED WITH DOUBLE THICK TURNING
VANES.
F. ALL THERMOSTATS CONTROL DEVICES SHALL BE MOUNTED UP 48" ABOVE
FINISHED FLOOR, UNLESS OTHERWISE NOTED.
A. CONTRACTOR SHALL VERIFY LOCATION OF ALL PIPING, HVAC EQUIPMENT, ETC.
SERVED BY EXISTING EQUIPMENT TO BE REMOVED. CONTRACTOR SHALL REMOVE
SUCH ITEMS ONLY IF THEY DO NOT SERVE FIXTURES TO REMAIN. ALL PIPING
SHALL BE CAPPED IN A CONCEALED LOCATION.
B. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING AND FINISHING SURFACES
(WALLS, FLOORS, CEILINGS) DAMAGED DURING REMOVAL OF EQUIPMENT AND
PIPING, UNLESS REMOVAL OR RENOVATION OF SURFACE IS COVERED UNDER
ANOTHER SECTION OF THIS CONTRACT.
C. CONTRACTOR SHALL DISPOSE OF OR RETURN ALL HVAC AND PLUMBING
FIXTURES, PIPING, ETC. TO OWNER IN ACCORDANCE WITH DIRECTION OF THE
ARCHITECT.
D. REMOVE ANY COLD WATER, HOT WATER, GAS, WASTES OR VENT PIPING
UNCOVERED IN EXISTING PARTITIONS TO BE REMOVED; REMOVE BACK TO ACTIVE
LINE AND CAP.
E. PIPE ROUTING IS APPROXIMATE ONLY. EACH BIDDER SHALL SATISFY THEMSELVES
AS TO EXISTING BUILDING CONDITIONS BEFORE SUBMITTING THEIR BID. NO
ALLOWANCE SHALL BE MADE AFTER CONTRACT IS AWARDED TO ALLOW FOR LACK
OF PRE-BID INSPECTION OF BUILDING BY SUCCESSFUL BIDDER.
F. COORDINATE WORK WITH OTHER TRADES TO MINIMIZE CONFLICTS AND "DOWN
TIME".
DEMOLITION GENERAL NOTES HVAC GENERAL NOTES
BUTTERFLY VALVE
GLOBE VALVE
CHECK VALVE
PLUG VALVE
TEMPERATURE CONTROL VALVE (2-WAY)
TEMPERATURE CONTROL VALVE (3-WAY)
SOLENOID VALVE
PIPE ANCHOR
SAFETY RELIEF VALVE
PRESSURE GAUGE WITH PIG TAIL AND COCK
THERMOMETER
STRAINER WITH BLOW-OFF VALVE
FLOW SWITCH
BALANCING VALVE
S
BALL VALVE
UNION
FLANGED CONNECTION
RISER DOWN
RISER UP
DROP
RISER UP
PIPE GUIDE
DIRECTION OF FLOW
VALVE IN RISER
POINT OF CONNECTION
THERMOSTATT
EQUIPMENT DESIGNATION
KEYED NOTES
Ø
MECHANICAL SYMBOL LEGEND
(ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS)
ABBR. SYMBOL DESCRIPTION
(E) EXISTING
(TYP) TYPICAL
AF AIR FILTER
BTU BRITISH THERMAL UNITS
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
DG DOOR GRILLE
BDD BACKDRAFT DAMPER
CD CEILING DIFFUSER
EAD EXHAUST AIR DAMPER (OPPOSED BLADE)
ELV ELEVATION
EWT ENTERING WATER TEMPERATURE
FFE FINISH FLOOR ELEVATION
ESP EXTERNAL STATIC PRESSURE
G GRILLE
HP HORSE POWER
INV INVERT ELEVATION
LD LINEAR DIFFUSER
LWT LEAVING WATER TEMPERATURE
NA NOT APPLICABLE
NC NORMALLY CLOSED
GPH GALLONS PER HOUR
DIA DIAMETER
NO NORMALLY OPEN
OAD OUTSIDE AIR DAMPER (OPPOSED BLADE)
PH PHASE
PSIG POUNDS PER SQUARE INCH
R REGISTER WITH OBD
RAD RETURN AIR DAMPER
SP STATIC PRESSURE
°F DEGREES FAHRENHEIT
SW SIDEWALL
TG TRANSFER GRILLE
DD CONDENSATE DRAIN LINE
ABBR. SYMBOL DESCRIPTION ABBR. SYMBOL DESCRIPTION
MECHANICAL PIPING DESIGNATION
ABBR. SYMBOL DESCRIPTION
DEMOLISHED ITEM
20/12
20/12
DUCT TRANSITION
FLEXIBLE DUCTWORK
RIGID DUCTWORK - FIRST FIGURE IS SIDE SHOWN
RG/EG CEILING RETURN OR EXHAUST AIR INLET
CD CEILING SUPPLY AIR OUTLET
RA SIDEWALL RETURN OR EXHAUST AIR INLET
SA SIDEWALL SUPPLY AIR OUTLET
FC FLEXIBLE CONNECTION
ABBR. SYMBOL DESCRIPTION ABBR. SYMBOL DESCRIPTION
MECHANICAL DUCTWORK DESIGNATION
FD FIRE DAMPER
S/FD SMOKE/FIRE DAMPER
MVD MANUAL VOLUME DAMPER
UH UNIT HEATER
OBD OPPOSED BLADE DAMPER
PBD PARALLEL BLADE DAMPER
RR/EG SIDEWALL RETURN OR EXHAUST AIR INLET
SA SIDEWALL SUPPLY AIR OUTLET
RG/EG CEILING RETURN OR EXHAUST AIR INLET
CEILING SUPPLY AIR OUTLET
CEILING SUPPLY AIR OUTLET
RETURN OR EXHAUST DUCT DOWN
SUPPLY DUCT DOWN
RETURN OR EXHAUST DUCT UP
SUPPLY AIR DUCT UP
DUCT TRANSITION
FLEXIBLE DUCTWORK
RIGID DUCTWORK
CD
CD
U.N.O. UNLESS NOTED OTHERWISE
T
T
G
G
2701 Miles Road SE Albuquerque, New Mexico 87106
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W
RF
S C
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y O
F
SA
N
TA
F E
SA
N
TA
F
E, N
M
02/10/2026
M
EC
H
AN
IC
AL
D
EM
O
LI
TI
O
N P
LA
M106-101
SCALE: 1/4" = 1'-0"
MECHANICAL DEMOLITION PLAN
1. REMOVE EXHAUST FAN COMPLETE WITH ALL CONTROLS, INTERLOCKS, ANY
REMAINING DUCTWORK, ETC. REUSE EXISTING OPENING FOR NEW EXHAUST
SYSTEM, SEE NEW WORK PLAN. SEAL OPENING THRU ROOF PER DETAIL.
2. EXISTING GAS-FIRED UNIT HEATER HAS BEEN REMOVED AND REMOVE ALL
CONTROLS, FLUES, SUPPORTS, ETC. DISCONNECT EXISTING GAS PIPING AS
SHOWN.
3. EXISTING FLOOR DRAIN AND PIPING TO REMAIN UNDISTURBED.
4. REMOVE THERMOSTAT AND CONTROL WIRING FOR UNIT HEATER.
5. REMOVE EXISTING LOUVER COMPLETE. PREPARE PENETRATION THROUGH
EXTERIOR WALL FOR NEW LOUVER.
6. REMOVE EXISTING GAS PIPING AND SUPPORTS COMPLETE BACK TO
REGULATOR AND CAP.
7. CAP GAS PIPING 6" ABOVE REGULATOR FOR PIPING DROP SERVING REMOVED
UNIT HEATERS. EXISTING NATURAL GAS REGULATOR TO REMAIN.
8. EXISTING INTERIOR WALL HAS BE REMOVED.
A. REFER TO SHEET M106-001 FOR GENERAL NOTES AND LEGEND.
B. REFER TO SHEET M106-501 FOR DETAILS AND SCHEDULES.
KEYED NOTESGENERAL NOTES
LV-11
LV-2 1
T
EF-1 3
UH-1 2
UH-22
(3'X6')
(3'X3')
4DUCT DROPS DOWN
ON WALL TO 12" AFF
2701 Miles Road SE Albuquerque, New Mexico 87106
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W
RF
S C
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y O
F
SA
N
TA
F E
SA
N
TA
F
E, N
M
02/10/2026
M
EC
H
AN
IC
AL
P
LA
M106-102
SCALE: 1/4" = 1'-0"
MECHANICAL PLAN
1. INSTALL NEW LOUVER, SYMBOL LV-1 OR LV-2 (AS SHOWN), IN EXISTING
LOCATION WITH MOTORIZED DAMPER. INTERLOCK MOTORIZED DAMPER TO
OPEN WHEN EXHAUST FAN (EF-1) OPERATES AND TO CLOSE WHEN IT TURNS
OFF. CONTRACTOR TO FIELD VERIFY LOUVER SIZE PRIOR TO ORDERING.
2. INSTALL UNIT HEATER SUSPENDED FROM STRUCTURE UP 8' A.F.F. TO BOTTOM
OF UNIT HEATER. PROVIDE ELECTRONIC THERMOSTAT ON WALL UP 60" A.F.F. IN
LOCATION SHOWN. SET UNIT HEATER TO ACTIVATE UPON SENSING 60°F OR
LOWER SPACE TEMPERATURE.
3. INSTALL EXHAUST FAN, EF-1, ACCORDING TO DETAIL ON SHEET M106-501.
EXTEND 16"x16" DUCTWORK DOWN ON WALL AS SHOWN TO 12" A.F.F.
INTERLOCK EXHAUST FAN, EF-1, WITH MOTORIZED DAMPER TO OPEN WHEN
EXHAUST FAN OPERATES AND TO CLOSE WHEN IT TURNS OFF.
4. SECURE DUCTWORK TO WALL WITH UNISTRUT BRACKETS AND STRAPS PER
SMACNA DETAILS.
A. REFER TO SHEET M106-001 FOR GENERAL NOTES AND LEGEND.
B. REFER TO SHEET M106-501 FOR DETAILS AND SCHEDULES.
KEYED NOTESGENERAL NOTES
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W
RF
S C
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y O
F
SA
N
TA
F E
SA
N
TA
F
E, N
M
02/10/2026
M
EC
H
AN
IC
AL
D
ET
AI
LS
S
C H
ED
U
LE
S
M106-501
WELDED STEEL ANGLE
FRAME SECURED TO ROOF
STRUCTURE AND DUCT
SEE PLANS FOR
CONTINUATION
OF DUCTWORK
ANODIZED ALUMINUM
PREFABRICATED CURB
FOR ROOF INSTALLATION
RESILIENT PAD,
CAULK BOTH FACES
BIRDSCREEN
BACKDRAFT OR
MOTORIZED DAMPER
MOTOR OUT
OF AIRSTREAM
INSTALL EXHAUST
FAN TO BE LEVEL
FAN HOOD
AND COUNTER
FLASHING CAP
WOOD NAILER
ANCHOR TO
CURB (TYP.)
FIBER GLASS
INSULATION
ROOF
FULL SIZE DUCT
WITH 1" INTERIOR
ACOUSTICAL LINER
BETWEEN JOISTS
NOTE: INSTALLATION TYPICAL FOR
BELT AND DIRECT DRIVE FANS.
SCALE: NONE
BIRDSCREEN
ON INSIDE
MOTORIZED
BACKDRAFT
DAMPER
INTERLOCK DAMPER
MOTOR WITH EXHAUST
FAN OPERATION
WALL LOUVER
W/ "J" BLADES
EXTERIOR
WALL
ANCHOR LOUVER AND MOTORIZED
DAMPER TO WALL WITH MASONRY
INSERTS OR EXPANSION BOLTS.
MCNICHOLS ALUMINUM
RECTANGLE BAR GRATE, SERIES
19-S-4; 3/16" BAR THICKNESS, 2"
SPACING. SECURE TO EXISTING
ROOF CURB WITH 1/2" BOLT INTO
CURB THRU FRAME.
EXISTING ROOF
FLASHING TO REMAIN
ANGLE SUPPORT
SEE DRAWINGS
FOR OPENING SIZE
SEE ARCHITECTURAL
DRAWINGS FOR ROOF
CONSTRUCTION, FIELD
VERIFY EXACT MATERIALS
EXISTING 4" CANT
EXISTING FLASHING AND
COUNTERFLASHING TO REMAIN
SCALE: NONE
18 GAUGE GALVANIZED SHEET
METAL COVER SECURED OVER
CURB WITH 2" MIN. SCREWS.
CONTRACTOR NOTE:
· FIELD VERIFY EXACT DIMENSION OF
PENETRATION THRU ROOF.
· PROVIDE WEATHER-PROOF SEAL
UNDER GALVANIZED COVER PLATE.
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E106-101
D A
F B
U
IL
D
IN
G E
LE
C
TR
IC
A L
D
EM
O
LI
TI
O
N P
LA
11 41
NEW
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A H
AN K S
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E106-102
D A
F B
U
IL
D
IN
G E
LE
C
TR
IC
A L
M O
D
IF
IC
A
TI
O
N S
PL
A
12 41
NEW
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E106-103
D A
F B
U
IL
D
IN
G B
A
SE
M
EN
T
EL
EC
TR
IC
A
L M
O D
IF
IC
A
TI
O N
S
PL
13 41
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E106-104
D A
F B
U
IL
D
IN
G H
Y
PO
C H
LO
R
IT
E
A N
D P
O
LY
A
LU
M
IN
U M
C H
LO
R
ID
E
C H
EM
IC
A L
TA
N
K S
P
U M
PS
E
LE
C
TR
IC
A L
C O
N N
EC
TI
O
14 41
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
ACK
330R
ACK
330R
ACK
330R
2701 Miles Road SE Albuquerque, New Mexico 87106
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E106-501
H Y
PO
C
H
LO
R
IT
E
TA
N K
F
IL
L C
O N
TR
O
L
PA
N
EL
D
ET
A
IL
15 41
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E106-601
D A
F B
U
IL
D
IN
G E
X
IS
TI
N
G O
N E-
LI
N
E D
IA
G
R
M
16 41
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E106-602
D A
F B
U
IL
D
IN
G O
N E-
LI
N
E D
IA
G
R A
M M
O D
IF
IC
A
TI
O
17 41
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E106-801
D A
F B
U
IL
D
IN
G
C O
N
TR
O L
W
IR
IN
G
S C
H
ED
U
LE
A N
D I/
O T
A G
L
IS
T
SH
EE
#1
18 41
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E106-802
D A
F B
U
IL
D
IN
G
C O
N
TR
O L
W
IR
IN
G
S C
H
ED
U
LE
A N
D I/
O T
A G
L
IS
T
SH
EE
#2
19 41
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E106-803
D A
F B
U
IL
D
IN
G
C O
N
TR
O L
W
IR
IN
G
S C
H
ED
U
LE
A N
D I/
O T
A G
L
IS
T
SH
EE
#3
20 41
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E109-101
M
IX
ED
L
IQ
U
O R
P U
M
PS
EL
EC
TR
IC
A
L
PL
21 41
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E109-801
M
IX
ED
L
IQ
U
O R
P U
M
PS
C
O N
TR
O
L W
IR
IN
G S
C H
ED
U
LE
A
N D
I/O T
A G
L
IS
22 41
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E132-101
U V
B U
IL
D
IN
G
E
LE
C
TR
IC
A
L
PL
23 41
NEW
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E132-102
U V
B U
IL
D
IN
G
E
LE
C
TR
IC
A
L R
O O
M P
24 41
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E132-801
U V
B U
IL
D
IN
G
C
O N
TR
O
L W
IR
IN
G
SC
H
ED
U
LE
A N
D I
/O T
A G
L
IS
T
SH
EE
25 41
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E132-802
U V
B U
IL
D
IN
G
C
O N
TR
O
L W
IR
IN
G
SC
H
ED
U
LE
A N
D I/
O T
A G
L
IS
T
SH
EE
26 41
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E136-101
H
EA
D W
O R
K S
B U
IL
D
IN
G
E
LE
C
TR
IC
A
L
LA
Y O
U T
D R
A W
IN
G
27 41
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E136-102
H
EA
D W
O R
K S
B U
IL
D
IN
G
E
LE
C
TR
IC
A
L R
O O
M D
EM
O
LI
TI
O N
P
28 41
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E136-103
H
EA
D W
O R
K S
B U
IL
D
IN
G
F
IR
ST
F
LO
O
R
EL
EC
TR
IC
A
L
PL
29 41
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E136-104
H
EA
D W
O R
K S
B U
IL
D
IN
G
S
EC
O N
D F
LO
O
R
EL
EC
TR
IC
A
L
PL
A N
A N
D E
LE
V
A
TI
O
30 41
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E136-601
H
EA
D W
O R
K S
B U
IL
D
IN
G
O N
E-
LI
N E
D
IA
G R
M
31 41
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E136-801
H
EA
D W
O R
K S
B U
IL
D
IN
G
C
O N
TR
O
L W
IR
IN
G
SC
H
ED
U
LE
A N
D I/
O T
A G
L
IS
T
SH
EE
32 41
NEW
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E136-802
H
EA
D W
O R
K S
B U
IL
D
IN
G
C
O N
TR
O
L W
IR
IN
G
SC
H
ED
U
LE
A N
D I/
O T
A G
L
IS
T
SH
EE
33 41
NEW
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E136-803
H
EA
D W
O R
K S
B U
IL
D
IN
G
C
O N
TR
O
L W
IR
IN
G
SC
H
ED
U
LE
A N
D I/
O T
A G
L
IS
T
SH
EE
#3
34 41
NEW
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E136-804
H
EA
D W
O R
K S
B U
IL
D
IN
G
C
O N
TR
O
L W
IR
IN
G
SC
H
ED
U
LE
A N
D I/
O T
A G
L
IS
T
SH
EE
#4
35 41
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
2701 Miles Road SE Albuquerque, New Mexico 87106
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E137-101
N
PW
B U
IL
D
IN
G
A N
D P
O
ST
A
ER
A
TI
O N
B A
SI
N
E
LE
C
TR
IC
A
L
PL
36 41
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E137-801
N
PW
B U
IL
D
IN
G
C
O N
TR
O
L W
IR
IN
G A
N D
I/ O
T A
G L
37 41
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
2701 Miles Road SE Albuquerque, New Mexico 87106
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E149-101
O
FF
SI
TE
R
EU
SE
B
U
IL
D
IN
G E
LE
C
TR
IC
A L
PL
38 41
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E149-801
O
FF
SI
TE
R
EU
SE
B
U
IL
D
IN
G
C O
N
TR
O L
W
IR
IN
G
S C
H
ED
U
LE
A N
D I/
O T
A G
L
IS
T
SH
EE
39 41
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E149-802
O
FF
SI
TE
R
EU
SE
B
U
IL
D
IN
G
C O
N
TR
O L
W
IR
IN
G
S C
H
ED
U
LE
A N
D I/
O T
A G
L
IS
T
SH
EE
40 41
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
505 242 5700 office 505 242 0673 fax MolzenCorbin.com
PA
SE
O R
EA
L
W R
F
SC
A D
A , C
H
EM
F
EE
D , A
N D
V
FD
R
EP
LA
C
EM
EN
TS
C
IT
Y
O F
SA
N
TA
F
E
SA
N
TA
F E, N M
E99-801
G
EN
ER
A
TO
R
A N
D A
TS
C O
M M
U N
IC
A
TI
O
N W
IR
IN
G S
C H
ED
U
LE
A
N D
I/ O
L
41 41
M
E X
I C O
P R OFES
S
IO
N
A L
E N
G
IN
EER
ROBER
T
A
File details come from the government source that posted it. Updated .