This package includes construction drawings and details for a federal project to construct a Primary Care and Women's Health building for the Department of Veterans Affairs in Marion, Illinois. The drawings show site plans, utility plans, grading plans, erosion control plans, sanitary plans and profiles, water service plans and profiles, and construction details. Relevant details include specifications for yard inlets, drainage basins, utility connections, and erosion control measures.

The related federal contract opportunity is a solicitation to construct the Primary Care and Women's Health building according to the specifications in the construction drawings. Offerors are required to submit responses by the date listed. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 15.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseENGINEER OF RECORD MILLER-REMICK LLC

PROFESSIONAL ENGINEERCONSULTANT

321 4 5 6 7 8 9 10

CONSTRUCT PRIMARY CARE AND

WOMEN'S HEALTH BUILDING

2401 W. MAIN STREET, MARION, IL

657-503

2021-06-30 SLP DSMRevisions: Date:

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR

ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND

SIGNATURE OF THE PROFESSIONAL ENGINEEER

MR PROJECT NO:

CONSTRUCTION DOCUMENTS

o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t o n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t th re e in c h o n e fo o t 6

1221 N PENNSYLVANIA ST. INDIANAPOLIS, IN 46202

317.800.6388 WWW.GUIDONDESIGN.COM1. BID RFI'S 06/01/2023

STATE OF

PE 10302594

ST

AC

EY L. PAUL

RE

GISTERED

INDIA NA

PROFESSI ONAL EN

GI

N

EE

R

CU102

UTILITY PLAN

N

0 12060

N

0 2010

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseENGINEER OF RECORD MILLER-REMICK LLC

PROFESSIONAL ENGINEERCONSULTANT

321 4 5 6 7 8 9 10

CONSTRUCT PRIMARY CARE AND

WOMEN'S HEALTH BUILDING

2401 W. MAIN STREET, MARION, IL

657-503

2021-06-30 SLP DSMRevisions: Date:

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR

ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND

SIGNATURE OF THE PROFESSIONAL ENGINEEER

MR PROJECT NO:

CONSTRUCTION DOCUMENTS

o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t 6

1221 N PENNSYLVANIA ST. INDIANAPOLIS, IN 46202

317.800.6388 WWW.GUIDONDESIGN.COM1. BID RFI'S 06/01/2023

STATE OF

PE 10302594

ST

AC

EY L. PAUL

RE

GISTERED

INDIA NA

PROFESSI ONAL EN

GI

N

EE

R

CU103

UTILITY PLAN

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseENGINEER OF RECORD MILLER-REMICK LLC

PROFESSIONAL ENGINEERCONSULTANT

321 4 5 6 7 8 9 10

CONSTRUCT PRIMARY CARE AND

WOMEN'S HEALTH BUILDING

2401 W. MAIN STREET, MARION, IL

657-503

2021-06-30 SLP DSMRevisions: Date:

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR

ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND

SIGNATURE OF THE PROFESSIONAL ENGINEEER

MR PROJECT NO:

CONSTRUCTION DOCUMENTS

o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t 6

1221 N PENNSYLVANIA ST. INDIANAPOLIS, IN 46202

317.800.6388 WWW.GUIDONDESIGN.COM1. BID RFI'S 06/01/2023

STATE OF

PE 10302594

ST

AC

EY L. PAUL

RE

GISTERED

INDIA NA

PROFESSI ONAL EN

GI

N

EE

R

CU501

UTILITY DETAILS

1.

0'

O.D. + 12"

CONC. COLLAR

OUTLET PIPE

PL

AN

S

SE

E

FILLET

4" CONC.

INV. ELEV.

O.D. + 16" 24"

CONC. BASE

CONCRETE COLLAR

RIM ELEVATION (RE)

6"

6"

RCP PIPE

NTS

BIO-RETENTION BASIN SYSTEM

INLET PIPE

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseENGINEER OF RECORD MILLER-REMICK LLC

PROFESSIONAL ENGINEERCONSULTANT

321 4 5 6 7 8 9 10

CONSTRUCT PRIMARY CARE AND

WOMEN'S HEALTH BUILDING

2401 W. MAIN STREET, MARION, IL

657-503

2021-06-30 SLP DSMRevisions: Date:

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR

ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND

SIGNATURE OF THE PROFESSIONAL ENGINEEER

MR PROJECT NO:

CONSTRUCTION DOCUMENTS

o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t 6

1221 N PENNSYLVANIA ST. INDIANAPOLIS, IN 46202

317.800.6388 WWW.GUIDONDESIGN.COM1. BID RFI'S 06/01/2023

STATE OF

PE 10302594

ST

AC

EY L. PAUL

RE

GISTERED

INDIA NA

PROFESSI ONAL EN

GI

N

EE

R

CU502

UTILITY DETAILS

NOTES:

BASIS OF DESIGN IS NYLOPLAST DRAIN BASIN WITH NYLOPLAST WEIR, APPROVED EQUALS SHALL BE

ALLOWED.

1 - WEIR AVAILABLE FOR ALL 24" - 30" STRUCTURE OPTIONS (CUSTOM BASIN,

ROAD & HIGHWAY, & CURB INLET).

2 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS.

RISERS ARE NEEDED FOR BASINS OVER 84" DUE TO SHIPPING RESTRICTIONS.

3 - HEIGHT OF WEIR TO BE DETERMINED BY ENGINEER. WEIR HEIGHT CANNOT

EXCEED 84" DUE TO MANUFACTURING AND SHIPPING RESTRICTIONS.

4 - WEIR MANUFACTURED TO MINIMIZE LOSS OF OUTLET PIPE OPEN AREA.

5 - ADAPTERS CAN BE MOUNTED ON ANY ANGLE 0° TO 360°.

6 - DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO

ASTM D3212 FOR CORRUGATED HDPE (ADS N-12/HANCOR DUAL WALL),

N-12 HP, & PVC SEWER (4" - 24").

7 - FRAMES, GRATES, COVERS, HOODS, & BASE PLATES SHALL BE DUCTILE IRON

PER ASTM A536 GRADE 70-50-05.

YARD INLET WITH WEIR

INLET & OUTLET ADAPTER

THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER GRANULAR

MATERIAL MEETING THE REQUIREMENTS OF CLASS I, CLASS II, OR CLASS III

MATERIAL AS DEFINED IN ASTM D2321. BEDDING & BACKFILL FOR SURFACE

DRAINAGE INLETS SHALL BE PLACED & COMPACTED UNIFORMLY IN

ACCORDANCE WITH ASTM D2321.

NTS

INLET PIPE

(1) OUTLET WEIR

(1) 24" - 30"

DRAIN BASIN BODY

30" FRAME &

BEHIVE COVER

CONTROLLED

OUTLET

UNDER DRAIN

(INLET)

ST-B2 SIDE SECTION & TOP VIEW:

ENLARGED TO SHOW DETAIL

ELEV. 464.50

6" SUMP

ELEV. 458.55

ELEV. 458.56

RECTANGULAR WIER AT ELEV. 458.55

DEPTH = 1'-11"

WIDTH = 1.5"

RECTANGULAR WEIR AT ELEV. 461.46

DEPTH = 0'-6"

WIDTH = 1.25'

ELEV. 465.00

INLET PIPE

(1) OUTLET WEIR

(1) 24" - 30"

DRAIN BASIN BODY

30" FRAME &

BEHIVE COVER

CONTROLLED

OUTLET

UNDER DRAIN

(INLET)

ST-C2 SIDE SECTION & TOP VIEW:

ENLARGED TO SHOW DETAIL

ELEV. 465.50

6" SUMP

ELEV. 461.68

ELEV. 461.78

2" CIRCULAR

ORIFICE AT ELEV.

461.68

3" CIRCULAR

ORIFICE AT ELEV.

ELEV. 466.01

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseENGINEER OF RECORD MILLER-REMICK LLC

PROFESSIONAL ENGINEERCONSULTANT

321 4 5 6 7 8 9 10

CONSTRUCT PRIMARY CARE AND

WOMEN'S HEALTH BUILDING

2401 W. MAIN STREET, MARION, IL

657-503

2021-06-30 SLP DSMRevisions: Date:

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR

ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND

SIGNATURE OF THE PROFESSIONAL ENGINEEER

MR PROJECT NO:

CONSTRUCTION DOCUMENTS

o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t 6

1221 N PENNSYLVANIA ST. INDIANAPOLIS, IN 46202

317.800.6388 WWW.GUIDONDESIGN.COM1. BID RFI'S 06/01/2023

STATE OF

PE 10302594

ST

AC

EY L. PAUL

RE

GISTERED

INDIA NA

PROFESSI ONAL EN

GI

N

EE

R

CU503

UTILITY DETAILS

Ø 12" DOMED DUCTILE

IRON YARD INLET

Sheets and Views
CI001 CIVIL NOTES
CD101 DEMOLITION PLAN
CS101 SITE PLAN
CS102 SITE PLAN
CS103 SITE PLAN
CS104 SITE PLAN
CS501 SITE DETAILS
CS502 SITE DETAILS
CS503 SITE DETAILS
CS504 SITE DETAILS
CG101 GRADING PLAN
CG102 GRADING PLAN
CG103 GRADING PLAN
CU101 UTILITY OVERALL LAYOUT PLAN
CU102 UTILITY PLAN
CU103 UTILITY PLAN
CU201 SANITARY PLAN AND PROFILE
CU202 SANITARY PLAN AND PROFILE
CU203 SANITARY PLAN AND PROFILE
CU204 WATER SERVICE PLAN AND PROFILE
CU501 UTILITY DETAILS
CU502 UTILITY DETAILS
CU503 UTILITY DETAILS
CJ101 EROSION CONTROL PLAN
CJ102 EROSION CONTROL PLAN
CJ501 EROSION CONTROL DETAILS
LP101 LANDSCAPE PLAN
LP102 LANDSCAPE PLAN
LP103 LANDSCAPE DETAILS