S02 SOL-Att-12 - Relocate Electron Microscope Drawings Vol 2.pdf

PDF 6 MB Posted

Attached to
Z1DA--Madison MATOC Federal contract opportunity
Solicitation number
36C25221R0070
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12

About this file

This document announces a pre-solicitation notice for a Multiple Award Task Order Contract (MATOC) for construction services at the Wm S. Middleton VA Hospital in Madison, Wisconsin. The VA plans to award multiple Indefinite-Delivery Indefinite-Quantity contracts valued between $2,000 to $7,000,000 per task order, with a maximum of $40 million per contractor over five years. Work includes construction, repair, alteration, and new facilities in areas such as HVAC, plumbing, electrical, communications, and site work. The solicitation will be posted on or around June 1, 2021 under NAICS code 236220 with a $36.5 million size standard. Offerors must be verified Service-Disabled Veteran-Owned Small Businesses. Task orders will be competitively issued to all selected MATOC contractors.

View the file

Other files for this federal contract opportunity

Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

POC: Aslam Husain

Wm S. Middleton, Madison, WI

607-19-115

Project Director

Revisions: Date:

9245 Calumet Ave. Suite 205, Phone: (219) 836-2120 Fax: (219) 836-1129 Munster, IN 46321

12.11.20

RELOCATE ELECTRON

MICROSCOPE

Schematic Design Documents 6.4.2020 Design Development 7.30.2020 65% Construction Documents 9.14.2020 95% Construction Documents 10.29.2020 100% Construction Documents 12.11.2020

EXHAUST FAN SCHEDULE

DE

SI

GN

AT

IO

N SERVICE LOCATION TYPE

MA

XI

MU

M

AI

R

QU

AN

TIT

Y

(C

FM

TO

TA

L S

TA

TIC

P

RE

SS

UR

E

(IN

OF

W

AT

ER

FA

N

SP

EE

D (R

PM

W

HE

EL

D

IA

ME

TE

R

(IN

CH

ES

DI

SC

HA

RG

E

DI

RE

CT

IO

N

CO

NT

RO

L T

YP

E

FAN MOTOR DATA

MANUFACTURER MODEL NO. REMARKS

MO

TO

R

BH

P

MO

TO

R

HP

SP

EE

D (R

PM

VO

LT

AG

E

PH

AS

E

MO

TO

R

LO

CA

TIO

N

ST

AR

TE

R

BY

(D

IV

O R

) ST

AR

TE

R

TY

PE

A : A

FD

B

AU

TO

TR

AN

SF

C : A

CR

OS

S

TH

E

LIN

E

EM

ER

GE

NC

Y

PO

W

ER

RE

Q'

D (Y

/N

EF-3A-01 DWING DB1

2ND

FLOOR

ROOF

UPBLAST 3.0 2956 - UP VFD 1.55 2 3600 208 3 - 16 C NO NOTE 2

NOTES:

1. REFER TO SPECIFICATION "NOISE SOUND & VIBRATION CONTROL", FOR VIBRATION ISOLATION AND INERTIA BASE REQUIREMENTS.

2. FAN IS A MIXED FLOW INDUCED DILUTION FAN WITH EXHAUST NOZZLE AND OUTLET SILENCER. FAN INDUCED FLOW RATE IS 2,462 CFM AND THE WINDBAND EXHAUST FLOW IS 3,962 CFM FOR 264% DILUTION AND A 21.37' EFFECTIVE STACK HEIGHT IN A 15 MPH WIND.

BASIS OF DESIGN

GENERAL NOTES:

A. CONTRACTOR SHALL VERIFY/COORDINATE ALL RATINGS FOR EQUIPMENT SUPPLIED BY THE SELECTED MANUFACTURER. WHERE RATINGS ARE

OTHER THAN AS NOTED ON MECHANICAL/ELECTRICAL COORDINATION SCHEDULE, DISCONNECTS, MOTOR STARTERS, OVERCURRENT DEVICES AND RELATED REVISIONS SHALL BE PROVIDED ACCORDINGLY. THE CONTRACTOR THAT FURNISHES EQUIPMENT WITH RATINGS OTHER THAN AS NOTED SHALL BE RESPONSIBLE FOR ALL COORDINATION AND COSTS FOR REVISIONS TO ACCOMMODATE SELECTED EQUIPMENT.

B. ALL FRACTIONAL HORSEPOWER MOTORS SHALL BE PROVIDED WITH INTEGRAL OVERLOAD PROTECTION.

C. HORSEPOWER RATED TOGGLE SWITCHES (SH): FOR 120 V MOTORS LESS THAN 1/2 HP, PROVIDE 15 AMP BREAKER IN PANEL.

FOR 120 V MOTORS RATED 1/2 HP OR 3/4 HP, PROVIDE 20 AMP BREAKER IN PANEL.

TWIN CITY

OR APPROVED EQUAL

3. FAN TO BE MOUNTED ON ROOF CURB 18" HIGH . PROVIDED WITH PLENUM WITH SIDE INLET OPTION, VORTEX BREAKER AND HAVE AN ISOLATION DISCHARGE DAMPER AND A LOUVER RAIN HOOD.

1,500

VARIABLE FREQUENCY DRIVES

TAG UNITS SERVING LOCATION VOLTAGE

FULL LOAD

AMPS

DESCRIPTION

VFD-1 EF-3A-1 3RD FLOOR 208/120V, 3

PHASE, 4 WIRE

WITH BYPASS

ISOLATION

ROOM 229

FUME HOOD REGISTER - GRILLE - DIFFUSER SCHEDULE

MARK FUNCTION TYPE CFM

MAX SIZE BORDER MATERIAL

FINISH ACCESS. MANUFACTURER REMARKS

N.C.

(INCHES) OR FRAME STEEL & MODEL NO.

REMARKS:

1. PROVIDE SPECIFIC NOISE CRITERIA (NC) DATA FOR EACH LINE ITEM WITH SHOP DRAWINGS.

2. COORDINATE BORDER OR FRAME TYPE WITH WALL TYPE.

3. COORDINATE FINISH WITH ARCHITECT/ENGINEER.

4. DIFFUSER / GRILLE TO BE CEILING RECESSED. SEE PLANS

5. DIFFUSER / GRILLE TO HAVE VOLUME DAMPER IN BRANCH DUCTWORK. SEE PLANS

EXHAUST -- X STND.

WHITE 1, 2, 3, 4, 5

80-273 6" Ø

NECK

50- 100 24 x 24

LAY-IN

N-EG1 PERF. PANEL

12 x 12

15-24 X 1, 2, 3, 4, 524 x 24

LAY-IN

N-EG2 PERF. PANEL

24 x 24

STND.

WHITE

178 -

8 x 8

NECK

13-32

DESIGN

N-SD1

N-SD3

N-SD2

1, 2, 3, 4, 5

SQUARE FACE

NOMINAL PNL.

24 X 24 X STND.

WHITE

SUPPLY 24 x 24

LAY-IN

1, 2, 3, 4, 5

SQUARE FACE

NOMINAL PNL.

12 X 12

X STND.

WHITE NAILOR RNSSUPPLY

SUPPLY 24 x 24

LAY-IN

1, 2, 3, 4, 5X STND.

WHITE

6" Ø

NECK

13-27

8" Ø

NECK

13-28

SQUARE FACE

NOMINAL PNL.

24 X 24 200-

100-

24 x 24

LAY-IN

TVIFE 122 XV7

EXHAUST

N-SD4 SUPPLY 24 x 24

LAY-IN X STND.

WHITE

10" Ø

NECK

16-31330-

SQUARE FACE

NOMINAL PNL.

24 X 24

NAILOR RNS

NAILOR RNS

NAILOR RNS

NAILOR 4360

NAILOR 4360

1, 2, 3, 4, 5

10-25 X 1, 2, 3, 4, 524 x 24

LAY-IN

N-EG3 STND.

WHITE

273 -

EXHAUST NAILOR 4360

6" Ø

NECK

PERF. PANEL

24 x 24

10" Ø

NECK

36C25221R0070 Attachment 11

AutoCAD SHX Text

DS

AutoCAD SHX Text

MECHANICAL SCHEDULES

AutoCAD SHX Text Elec Coil

AutoCAD SHX Text Valve Size

AutoCAD SHX Text Elec Coil

AutoCAD SHX Text Valve Type

AutoCAD SHX Text Control

AutoCAD SHX Text Control

AutoCAD SHX Text Valve #

AutoCAD SHX Text Control

AutoCAD SHX Text

ELECTRICAL

AutoCAD SHX Text

REQUIREMENT

AutoCAD SHX Text

POWER

AutoCAD SHX Text

MANUFACTURER

AutoCAD SHX Text

SIZING

AutoCAD SHX Text

TRANSFORMER

AutoCAD SHX Text

SERVICE

AutoCAD SHX Text Control Valves

AutoCAD SHX Text

QTY

AutoCAD SHX Text

FCV-2

AutoCAD SHX Text

5 VA

AutoCAD SHX Text

BELIMO

AutoCAD SHX Text

OR EQUAL

AutoCAD SHX Text Modulating

AutoCAD SHX Text

2 - WAY

AutoCAD SHX Text Actuator

AutoCAD SHX Text

24VAC

AutoCAD SHX Text

%%P 20%%%, 60HZ

AutoCAD SHX Text

24VDC

AutoCAD SHX Text

%%P 10%%%, 60HZ

AutoCAD SHX Text

REFERENCE

AutoCAD SHX Text

AutoCAD SHX Text

MP100, MP101

AutoCAD SHX Text

HEATING

AutoCAD SHX Text

HOT WATER

AutoCAD SHX Text

5/8" NPT

AutoCAD SHX Text

FCV-1

AutoCAD SHX Text

5 VA

AutoCAD SHX Text

BELIMO

AutoCAD SHX Text

OR EQUAL

AutoCAD SHX Text Modulating

AutoCAD SHX Text

2 - WAY

AutoCAD SHX Text Actuator

AutoCAD SHX Text

24VAC

AutoCAD SHX Text

%%P 20%%%, 60HZ

AutoCAD SHX Text

24VDC

AutoCAD SHX Text

%%P 10%%%, 60HZ

AutoCAD SHX Text

AutoCAD SHX Text

COOLING

AutoCAD SHX Text

CHILLED WATER

AutoCAD SHX Text

5/8" NPT

AutoCAD SHX Text

MP100

AutoCAD SHX Text M600

AutoCAD SHX Text

1/2" NPT

AutoCAD SHX Text

HOODFRIDGE

VACUUM / ROUGHING PUMPS,

AIR COMPRESSOR

LARGE

OVEN

T

PC

POWER SUPPLY

SMALL OVEN

PAC/ UW EPIC

INERFACE

NEW 5 H. LATERAL FILE

RELOCATED COMPUTER TABLE,

CHAIR AND 4 DRAWER PEDSTAL

CHILLER

PROPOSED MILLI-Q

WATER PURIFICATION

SYSTEM - COUNTER

TOP UNIT

KNIFE CUTTERS

OPEN SHELVES

PROCESSING

EMBED. ITEMS

WALLS, DOOR AND FRAME TO

SEE SOUND PROOF

CONSTRUCTION

EQUIPMENT

DB1-229A

MICROSCOPE

ROOM

DB1-229

LAB

DB1-231

OFFICE

DB1-232

EMBEDDING-

GHOSTING

C3

I

SAFETY OFFICE

A26

SAFETY OFFICE

A26A

COMPUTER LAB

A24

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

POC: Aslam Husain

Wm S. Middleton, Madison, WI

607-19-115

Project Director

Revisions: Date:

9245 Calumet Ave. Suite 205, Phone: (219) 836-2120 Fax: (219) 836-1129 Munster, IN 46321

RELOCATE ELECTRON

MICROSCOPE

B

A

C

G

D

GENERAL NOTES

LEGEND

AC-101

AC-109

AC-103

36C25221R0070 Attachment 11

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 200A

AutoCAD SHX Text 200B

AutoCAD SHX Text 200C

AutoCAD SHX Text 200D

AutoCAD SHX Text

AutoCAD SHX Text

DB1-196

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 241A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SW 7

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text D

AutoCAD SHX Text P

AutoCAD SHX Text

DB1-207

AutoCAD SHX Text

DB1-210

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A46

AutoCAD SHX Text A3

AutoCAD SHX Text

DG210

AutoCAD SHX Text

DG265

AutoCAD SHX Text

DG195

AutoCAD SHX Text No. 7

AutoCAD SHX Text

DG199

AutoCAD SHX Text

DG204A

AutoCAD SHX Text

DG196

AutoCAD SHX Text

DG203

AutoCAD SHX Text

DG288

AutoCAD SHX Text

DG284

AutoCAD SHX Text

DG200

AutoCAD SHX Text

DG198

AutoCAD SHX Text

DG285

AutoCAD SHX Text

DG282

AutoCAD SHX Text

DG279

AutoCAD SHX Text

DG202

AutoCAD SHX Text A15

AutoCAD SHX Text A17

AutoCAD SHX Text A31

AutoCAD SHX Text A16

AutoCAD SHX Text A32

AutoCAD SHX Text A28

AutoCAD SHX Text A33

AutoCAD SHX Text A33A

AutoCAD SHX Text

DG204

AutoCAD SHX Text

DG211

AutoCAD SHX Text A14A

AutoCAD SHX Text A14

AutoCAD SHX Text A35

AutoCAD SHX Text A30

AutoCAD SHX Text A10

AutoCAD SHX Text A9

AutoCAD SHX Text A38

AutoCAD SHX Text A7

AutoCAD SHX Text A6

AutoCAD SHX Text No. 4

AutoCAD SHX Text A36

AutoCAD SHX Text A37

AutoCAD SHX Text A38A

AutoCAD SHX Text A38B

AutoCAD SHX Text A40

AutoCAD SHX Text A41

AutoCAD SHX Text A5

AutoCAD SHX Text A4

AutoCAD SHX Text A43

AutoCAD SHX Text A44

AutoCAD SHX Text A6-A

AutoCAD SHX Text A45

AutoCAD SHX Text

DG405

AutoCAD SHX Text

DG421

AutoCAD SHX Text

DG407

AutoCAD SHX Text

DG422

AutoCAD SHX Text

DG418

AutoCAD SHX Text

DG423

AutoCAD SHX Text

DG401

AutoCAD SHX Text

DG420

AutoCAD SHX Text

DG424

AutoCAD SHX Text

DG287

AutoCAD SHX Text

DG285A

AutoCAD SHX Text

DG283

AutoCAD SHX Text

DG283A

AutoCAD SHX Text

DG216

AutoCAD SHX Text

DG215

AutoCAD SHX Text

DG214

AutoCAD SHX Text

DG282A

AutoCAD SHX Text A18

AutoCAD SHX Text

DG194

AutoCAD SHX Text

DG286

AutoCAD SHX Text A17B

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B111

AutoCAD SHX Text

ENTRY

AutoCAD SHX Text

WAY

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B111A

AutoCAD SHX Text

TELEPHONE

AutoCAD SHX Text

CLOSET

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B48

AutoCAD SHX Text

STERILE

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A46A

AutoCAD SHX Text A1

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

GG

AutoCAD SHX Text

AC-109

AutoCAD SHX Text

AC-108 RELIEF FAN

AutoCAD SHX Text

AC-108

AutoCAD SHX Text

EF-108 EXHAUST FAN

AutoCAD SHX Text M700

AutoCAD SHX Text

MECHANICAL AIR BALANCING DRAWINGS AND NOTES

AutoCAD SHX Text N

AutoCAD SHX Text

KEY PLAN

AutoCAD SHX Text Not to Scale

AutoCAD SHX Text

DG-249, 2ND FLR ROOF

AutoCAD SHX Text A23,A24,A25,A26B

AutoCAD SHX Text

A WING GROUND

AutoCAD SHX Text

D WING

AutoCAD SHX Text

AND 8TH FLOOR MECHANICAL D8201

AutoCAD SHX Text

D WING FUME HOOD CHASE

AutoCAD SHX Text

& 3RD FLOOR

AutoCAD SHX Text

DB1-229,230,231,232

AutoCAD SHX Text

-HVAC BALANCING PLAN

AutoCAD SHX Text 1/16" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

PLAN NORTH

AutoCAD SHX Text

D WING BASEMENT LEVEL 1

AutoCAD SHX Text

-HVAC BALANCING PLAN

AutoCAD SHX Text 1/16" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

A WING GROUND FLOOR

AutoCAD SHX Text

PLAN NORTH

AutoCAD SHX Text

1. THE DRAWINGS DO NOT PRESENT FULLY DETAILED ASPECTS OF THE EXISTING PHYSICAL CONDITIONS. THE CONTRACTOR SHALL BE RESPONSIBLE TO VISUALLY IDENTIFY INTERFERENCES AND TO MAKE NECESSARY ADJUSTMENTS IN THE FIELD. 2. THE DIAGRAM IS INTENDED TO SHOW THOSE ITEMS THAT ARE AT RECOMMENDED AND CURRENT DESIGN REQUIREMENTS AND DOES NOT REFLECT ANY ADDITIONAL ITEMS BOTH PHYSICALLY AND EXISTING DESIGN CONDITIONS. 3. CONTRACTOR SHALL BE RESPONSIBLE TO IDENTIFY DISCREPANCIES AND BRING THEM TO THE ATTENTION OF THE DEPARTMENT OF VETERANS AFFAIRS (V.A.) REPRESENTATIVES AS SOON AS POSSIBLE DURING BIDDING TO OBTAIN GUIDANCE. THIS SHALL NOT ALLEVIATE THE CONTRACTOR OF THE RESPONSIBILITY TO PROVIDE A FULLY FUNCTIONING SYSTEM. 4. CONTRACTOR TO INCLUDE PROVISIONS FOR CHECKING AC-101, CONTRACTOR TO INCLUDE PROVISIONS FOR CHECKING AC-101, AC-103 AND AC-109. ADJUST THE SUPPLY FAN VFD SPEED AS REQUIRED IN ORDER TO BALANCE THE NEW SYSTEM. 5. CONTRACTOR TO INCLUDE PROVISIONS FOR CHECKING EXHAUST CONTRACTOR TO INCLUDE PROVISIONS FOR CHECKING EXHAUST FAN EF-108 AND CF-103 AFFECTED BY MODIFICATIONS TO THE WORK

AutoCAD SHX Text

DOUBLE POSITIVE PRESSURE

AutoCAD SHX Text

SINGLE POSITIVE PRESSURE

AutoCAD SHX Text

DOUBLE NEGATIVE PRESSURE

AutoCAD SHX Text

SINGLE NEGATIVE PRESSURE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text AWING GROUND FLOOR BALANCING NOTES 1. CONTRACTOR SHALL TEST FOR EACH ROOM IN PROJECT A FULL CONTRACTOR SHALL TEST FOR EACH ROOM IN PROJECT A FULL RANGE OF AIR FLOW RATES AND PRESSURES. 2. CONTRACTOR TO REFER TO MECHANICAL DRAWINGS, SCHEDULES CONTRACTOR TO REFER TO MECHANICAL DRAWINGS, SCHEDULES AND CONTROL DRAWINGS FOR SPECIFIC EQUIPMENT REFERENCE AND DETAILS 3. CONTRACTOR TO MAINTAIN REQUIREMENTS FOR ROOM PRESSURE CONTRACTOR TO MAINTAIN REQUIREMENTS FOR ROOM PRESSURE RELATIONSHIPS WITH ADJOINING AREAS AS INDICATED BELOW. WORK HVAC TAB AIR CHANGES WITH REQUIREMENTS BELOW: 3.1. A24, A26, A26A A24, A26, A26A PRESSURE= POSITIVE WITH RESPECT TO ADJOINING CORRIDOR A31 4. ADJUST EXHAUST VALUES TO MAINTAIN POSITIVE AND NEGATIVE ADJUST EXHAUST VALUES TO MAINTAIN POSITIVE AND NEGATIVE PRESSURES. SEE TESTING AND BALANCE NOTES ON DETAILS (M701). SEE SEQUENCE OF OPERATIONS DRAWING M701 FOR MORE INFORMATION. 5. ADJUST SUPPLY VALUES TO MAINTAIN POSITIVE AND NEGATIVE ADJUST SUPPLY VALUES TO MAINTAIN POSITIVE AND NEGATIVE PRESSURES. SEE TESTING AND BALANCE NOTES ON DETAILS (M701). SEE SEQUENCE OF OPERATIONS DRAWING M701 FOR MORE INFORMATION. 6. PROVIDE ADJUSTED VALUES OF FLOW RATES TO VA FOR REVIEW TO PROVIDE ADJUSTED VALUES OF FLOW RATES TO VA FOR REVIEW TO MINIMIZE IMPACT ON NON-PROJECT AREAS. SEE MH100 FOR LOCATIONS. 7. THE CONTRACTOR SHALL PROVIDE A FULLY FUNCTIONAL SYSTEM. THE CONTRACTOR SHALL PROVIDE A FULLY FUNCTIONAL SYSTEM. ADDITIONAL EQUIPMENT AND COMPONENTS NOT SIZED HERE NEED TO BE PROVIDED PER MANUFACTURER RECOMMENDATIONS AND SUGGESTED INSTALLATION FOR THIS APPLICATION.

AutoCAD SHX Text DWING BASEMENT FLOOR LEVEL 1 BALANCING NOTES 1. CONTRACTOR SHALL TEST FOR EACH ROOM IN PROJECT A FULL RANGE OF AIR FLOW RATES AND PRESSURES. CONTRACTOR SHALL TEST FOR EACH ROOM IN PROJECT A FULL RANGE OF AIR FLOW RATES AND PRESSURES. 2. CONTRACTOR TO REFER TO MECHANICAL DRAWINGS, SCHEDULES AND CONTROL DRAWINGS FOR SPECIFIC CONTRACTOR TO REFER TO MECHANICAL DRAWINGS, SCHEDULES AND CONTROL DRAWINGS FOR SPECIFIC EQUIPMENT REFERENCE AND DETAILS 3. BALANCE NEW TERMINAL UNITS FOR THE FOLLOWING WITH RESPECT TO AC-101 ROOF TOP SUPPLY AIR. BALANCE NEW TERMINAL UNITS FOR THE FOLLOWING WITH RESPECT TO AC-101 ROOF TOP SUPPLY AIR. 3.1. LAB ROOM - DB1-231 AND 232 LAB ROOM - DB1-231 AND 232 PRESSURE= -NEGATIVE WITH RESPECT TO ADJOINING AREAS TO CORRIDOR DB1-196 TO CORRIDOR DB1-196 3.2. ELECTRON MICROSCOPE ROOM DB1-229 AND DB1-229A ELECTRON MICROSCOPE ROOM DB1-229 AND DB1-229A PRESSURE= POSITIVE WITH RESPECT TO ADJOINING TO DB1-231/232 3.3. CONFERENCE ROOM DB1-230 CONFERENCE ROOM DB1-230 PRESSURE= NEUTRAL WITH RESPECT TO CORRIDOR DB1-197 4. RE- BALANCE NEW GENERAL EXHAUST WITH RESPECT TO SUPPLY AND NEW FUME HOOD EXHAUST FOR THE RE- BALANCE NEW GENERAL EXHAUST WITH RESPECT TO SUPPLY AND NEW FUME HOOD EXHAUST FOR THE FOLLOWING ROOMS BY ADJUSTING TO CF-102 EXHAUST FAN. LAB ROOM - DB1-231 AND DB1-232 LAB ROOM - DB1-231 AND DB1-232 PRESSURE= NEGATIVE 5. RE- BALANCE NEW TERMINAL UNITS FOR THE FOLLOWING WITH RESPECT TO AC-103. RE- BALANCE NEW TERMINAL UNITS FOR THE FOLLOWING WITH RESPECT TO AC-103. CORRIDOR RM- DB1-197 AND DB1-196 CORRIDOR RM- DB1-197 AND DB1-196 PRESSURE= NEUTRAL WITH RESPECT TO NEW RENOVATION SPACES - SEE 3 ABOVE. 6. ALTHOUGH NOT ANTICIPATED, CONTRACTOR TO MAINTAIN REQUIREMENTS FOR ROOM PRESSURE RELATIONSHIPS ALTHOUGH NOT ANTICIPATED, CONTRACTOR TO MAINTAIN REQUIREMENTS FOR ROOM PRESSURE RELATIONSHIPS WITH ADJOINING AREAS AS INDICATED BELOW. WORK HVAC TAB AIR CHANGES INDICATED ON TABLE WITH REQUIREMENTS BELOW: PATHOLOGY LAB RM 207 PRESSURE= POSITIVE WITH RESPECT TO ADJOINING CORRIDOR DB1-197 7. ADJUST EXHAUST VALUES TO MAINTAIN POSITIVE AND NEGATIVE PRESSURES. SEE TESTING AND BALANCE NOTES ADJUST EXHAUST VALUES TO MAINTAIN POSITIVE AND NEGATIVE PRESSURES. SEE TESTING AND BALANCE NOTES ON DETAILS (M701). SEE SEQUENCE OF OPERATIONS DRAWING M701 FOR MORE INFORMATION. 8. ADJUST SUPPLY VALUES TO MAINTAIN POSITIVE AND NEGATIVE PRESSURES. SEE TESTING AND BALANCE NOTES ADJUST SUPPLY VALUES TO MAINTAIN POSITIVE AND NEGATIVE PRESSURES. SEE TESTING AND BALANCE NOTES ON DETAILS (M701). SEE SEQUENCE OF OPERATIONS DRAWING M700 FOR MORE INFORMATION. 9. THE CONTRACTOR SHALL PROVIDE A FULLY FUNCTIONAL SYSTEM. ADDITIONAL EQUIPMENT AND COMPONENTS NOT THE CONTRACTOR SHALL PROVIDE A FULLY FUNCTIONAL SYSTEM. ADDITIONAL EQUIPMENT AND COMPONENTS NOT SIZED HERE NEED TO BE PROVIDED PER MANUFACTURER RECOMMENDATIONS AND SUGGESTED INSTALLATION FOR THIS APPLICATION.

AutoCAD SHX Text

AREA OF NEW MECHANICAL WORK TO BE BALANCED

AutoCAD SHX Text

AREA OF NEW MECHANICAL WORK TO BE BALANCED

AREA OF NEW MECHANICAL WORK NOT TO BE BALANCED

THERMOSTAT CONTROL SEQUENCE

GENERAL

SYSTEM CONSISTS OF A THERMOSTAT AND HOT WATER CONTROL VALVE(S): REHEAT . SYSTEM HAS OCCUPANCY CONTROL. ZONE

POINTS ARE LINKED AND CONTROLLED BY THE SUPERVISORY CONTROLLER.

2-WAY VALVE CONTROL

1. IF ZONE IS UNOCCUPIED, MODULATE 2-WAY HW CONTROL VALVE(S) TO MAINTAIN ROOM TEMPERATURE TO ZONE UNOCC LOW

SP (ADJ, INITIALLY 60 F)

2. IF ZONE IS OCCUPIED, MODULATE 2-WAY HW CONTROL VALVE(S) TO MAINTAIN ROOM TEMPERATURE TO ROOM TEMP SP (ADJ, INITIALLY 70 F)

LOCAL TEMP SP

1. THERMOSTAT WILL ALLOW USER TO LOCALLY ADJUST ROOM TEMP SP BETWEEN THE BOUNDARIES OF ZONE OCC HILIMIT SP

(ADJ, INITIALLY 74 F) AND ZONE OCC LOLIMIT SP (ADJ, INITIALLY 68F)

LOSS OF POWER

1. CONTROL VALVES WILL REMAIN AT THEIR CURRENT SETTING DURING A LOSS OF ELECTRICAL POWER.

General Reheat Points List- A- WING Output Input Virtual Local Controller BAS Full BAS

IntegrationDigital Analog Digital Analog Digital Analog Visible Adjustable Overridable Visible Adjustable Overridable Reheat Command (V-1) X X X X X Reheat Feedback (V-1) X X

GENERAL VAVR CONTROL SEQUENCE

GENERAL NOTES

SYSTEM IS A VARIABLE AIR VOLUME BOX CONSISTING OF A DAMPER AND REHEAT,.

CONTROL WILL INCLUDE LOGIC TO PREVENT ALTERNATING BETWEEN HEATING AND COOLING AND TO ALLOW UNIT TO FULLY CLOSE DAMPERS/VALVES DURING UNOCCUPIED MODE IF THERE IS NOT A TEMPERATURE REQUIREMENT. COORDINATE WITH COR FOR

ACCEPTABLE CONTROL STRATEGIES.

BAS CENTRAL CONTROL LOGIC

THESE UNITS HAVE OCCUPANCY CONTROL THAT IS CONTROLLED BY THE BUILDING AUTOMATION SYSTEM AND IS LINKED FOR EACH

ZONE (COORDINATE WITH COR).

THESE UNITS HAVE A CENTRAL UNOCC HI SP (ADJ, INITIALLY 78 F) , UNOCC LO SP (ADJ, INITIALLY 65 F) AND UNOCC DEADBAND (ADJ, INITIALLY 4 F) THAT ARE LINKED FOR EACH ZONE (COORDINATE WITH COR).

THESE UNITS HAVE A CENTRAL PERIMETER ENABLE SP (ADJ, INITIALLY 45 F) THAT IS LINKED FOR EACH ZONE (COORDINATE WITH COR). IF [ OAT > PERIMETER ENABLE SP], PERIMETER ENABLE SP IS SET TO 'DISABLED'. IF [ OAT < PERIMETER ENABLE SP], PERIMETER ENABLE SP IS SET TO 'ENABLED'. OAT IS BASED ON THE GLOBAL OUTSIDE AIR TEMPERATURE.

IF ANY BUILDING AUTOMATION SYSTEM POINTS BECOME UNRELIABLE AT THE CONTROLLER (EX. LOSS OF COMMUNICATION), LOCAL

CONTROLLER WILL USE LAST KNOWN VALUES.

LOCAL CONTROLLER POINTS ARE TO BE INDEPENDENT AND ABLE TO BE OVERRIDDEN INDEPENDENT OF THE CENTRAL POINTS.

HEATING MODE:

1. DURING OCCUPIED MODE:

1.1. DAMPER WILL MODULATE TO MAINTAIN THE FLOW TO THE MINIMUM FLOW SP

1.2. REHEAT COMMAND WILL MODULATE TO MAINTAIN THE ROOM TEMPERATURE TO THE ROOM TEMPERATURE SP.

2. DURING UNOCCUPIED MODE:

2.1. IF { ROOM TEMPERATURE < UNOCC LO SP }, THEN THE FOLLOWING WILL OCCUR UNTIL { ROOM TEMPERATURE < UNOCC

LO SP + DEADBAND }:

2.1.1. DAMPER WILL MODULATE TO MAINTAIN THE FLOW TO THE MINIMUM FLOW SP

2.1.2. REHEAT WILL BE COMMANDED FULLY OPEN.

2.2. OTHERWISE:

2.2.1. DAMPER WILL BE COMMANDED FULLY CLOSED.

2.2.2. REHEAT WILL BE COMMANDED FULLY CLOSED.

General VAVR Points List and Exhaust Fan - D WING Output Input Virtual Local Controller BAS Full BAS

IntegrationDigital Analog Digital Analog Digital Analog Visible Adjustable Overridable Visible Adjustable Overridable Damper Command (D-1) X X X X X Damper Feedback (D-1) X X Reheat Command (V-1) X X X X X Reheat Feedback (V-1) X X

TT-1 (Discharge Temp) X X Flow (AFMD) X X Room Temperature (RT-1) X X X Room Temperature SP (RT-1) X X X X X X X X Minimum Flow SP X X X X X X Maximum Flow SP X X X X X X Unocc Deadband X X X X X X

Unocc Hi SP X X X X X X Unocc Lo SP X X X X X X

SELECT SCALE

TYPICAL VAV W/ REHEAT CONTROL DIAGRAM (D-WING)2

SELECT SCALE

EXHAUST FAN STATUS

EXHAUST FAN VSMC

EXHAUST FAN START/STOP

EF-STS

EF-SPD

EF-SST X

X X

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

POC: Aslam Husain

Wm S. Middleton, Madison, WI

607-19-115

Project Director

Revisions: Date:

9245 Calumet Ave. Suite 205, Phone: (219) 836-2120 Fax: (219) 836-1129 Munster, IN 46321

36C25221R0070 Attachment 11

AutoCAD SHX Text

WITH REHEAT CONTROL DIAGRAM

AutoCAD SHX Text

NTS

AutoCAD SHX Text

AutoCAD SHX Text

AFMD

AutoCAD SHX Text

HWS

AutoCAD SHX Text

HWR

AutoCAD SHX Text V-1

AutoCAD SHX Text

TT-1

AutoCAD SHX Text

ROOM THERMOSTAT

AutoCAD SHX Text

RT-1

AutoCAD SHX Text

PSL-1

AutoCAD SHX Text D-1

AutoCAD SHX Text

AIR FLOW SYSTEM DIAGRAM- DB1-D WING LEVEL 1 (LAB, ELECTRON MICROSCOPE)

AutoCAD SHX Text

LAB ELECTRON MICROSCOPE

AutoCAD SHX Text

NEW EXHAUST FAN EF-3A-1

AutoCAD SHX Text

HS

AutoCAD SHX Text

IT

AutoCAD SHX Text

VSMC

AutoCAD SHX Text

VARIABLE SPEED MOTOR CONTROLLER, TYP.

AutoCAD SHX Text

SST

AutoCAD SHX Text

ECC

AutoCAD SHX Text

STS

AutoCAD SHX Text

SPD

AutoCAD SHX Text

EXISTING EXHAUST FAN CF-102

AutoCAD SHX Text

CONFERENCE ROOM

AutoCAD SHX Text E.A.

AutoCAD SHX Text

AWING GROUND- FCU-1 FCU-2 RM A24

AutoCAD SHX Text

AWING GROUND- FCU-3 A26

AutoCAD SHX Text

CONTROLLER

AutoCAD SHX Text

EXISTING CONTROLS CIRCUIT

AutoCAD SHX Text

120VAC

AutoCAD SHX Text

CONTROL CABLE

AutoCAD SHX Text

12" DUCT

AutoCAD SHX Text

AIR FLOW

AutoCAD SHX Text

HWH

AutoCAD SHX Text

HWHR

AutoCAD SHX Text

AIR FLOW

AutoCAD SHX Text

CV-18

AutoCAD SHX Text

HWH

AutoCAD SHX Text

HWHR

AutoCAD SHX Text

AIR FLOW

AutoCAD SHX Text

HWH

AutoCAD SHX Text

HWHR

AutoCAD SHX Text

CV-19

AutoCAD SHX Text

CV-20

AutoCAD SHX Text E.A.

AutoCAD SHX Text

12" DUCT

AutoCAD SHX Text

SUPPLY AIR FROM AC-101

AutoCAD SHX Text

EF

AutoCAD SHX Text

EF

AutoCAD SHX Text

EF

AutoCAD SHX Text (0)

AutoCAD SHX Text (+,0)

AutoCAD SHX Text (+,0)

AutoCAD SHX Text

HOOD

AutoCAD SHX Text

ROOMS- A24, A26, A26A

AutoCAD SHX Text

PRECONDITIONED AIR FROM AC-109

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text (0)

AutoCAD SHX Text E.A.

AutoCAD SHX Text

EXISTING EXHAUST FAN EF-108 RM A14

AutoCAD SHX Text

FCU-1

AutoCAD SHX Text

FCU-2

AutoCAD SHX Text

FCU-3

AutoCAD SHX Text

RHC-1

AutoCAD SHX Text

RM A26

AutoCAD SHX Text

RM A24

AutoCAD SHX Text

RM A28

AutoCAD SHX Text

AIR FLOW SYSTEM DIAGRAM- A WING GROUND

AutoCAD SHX Text

RMS A,16, A17, A17B, A18

AutoCAD SHX Text V-1

AutoCAD SHX Text

ROOM THERMOSTAT

AutoCAD SHX Text

RT-1

AutoCAD SHX Text

CONTROLLER

AutoCAD SHX Text

HWS

AutoCAD SHX Text

HWR

AutoCAD SHX Text

RM A24 (2) RM A26. RM A26A

AutoCAD SHX Text E.A.

AutoCAD SHX Text E.A.

AutoCAD SHX Text

AutoCAD SHX Text

RM A28

AutoCAD SHX Text

120VAC

AutoCAD SHX Text

AutoCAD SHX Text

FOUR PIPE FAN COIL UNIT CONTROLS

AutoCAD SHX Text

NTS

AutoCAD SHX Text

HEATING COIL

AutoCAD SHX Text

RA

AutoCAD SHX Text

HWS

AutoCAD SHX Text

HWR

AutoCAD SHX Text

FCV-2

AutoCAD SHX Text

COOLING COIL

AutoCAD SHX Text

CHS

AutoCAD SHX Text

CHR

AutoCAD SHX Text

FCV-1

AutoCAD SHX Text

FAN

AutoCAD SHX Text

SST

AutoCAD SHX Text

HS

AutoCAD SHX Text T-1

AutoCAD SHX Text ROOM TEMPERATURE SENSOR WITH SPACE ADJUSTABLE WALL MOUNTED 48" [1200mm] AFF.

AutoCAD SHX Text T

AutoCAD SHX Text

PC

AutoCAD SHX Text FAN COIL SEQUENCE OF OPERATION (NONPATIENT ROOMS) FAN COIL SHALL OPERATE ON A SCHEDULE AS SET BY ECC. FAN SHALL RUN CONTINUOUSLY IN OCCUPIED MODE. FAN STATUS SHALL BE MONITORED AND AN ALARM MESSAGE SHALL BE GENERATED IN THE EVENT THE UNIT FAILS TO RUN. BETWEEN THE RANGE OF 70°-75° SPACETEMPERATURE BOTH FCV-1 & FCV-2 SHALL BE CLOSED. UPON RISE IN TEMPERATURE ABOVE 75°FCV-1 SHALL MODULATE OPEN TO MAINTAIN 75° F. UPON FALL IN TEMPERATURE BELOW 70° F.HEATING VALVE FCV-2 SHALL MODULATE TO OPEN TO MAINTAIN 70° F.

AutoCAD SHX Text

TT

AutoCAD SHX Text

CS

AutoCAD SHX Text

SA

AutoCAD SHX Text (0)

AutoCAD SHX Text

COORIDOR

AutoCAD SHX Text

OA

AutoCAD SHX Text (0)

AutoCAD SHX Text

RM A26A

AutoCAD SHX Text

FCU-4

AutoCAD SHX Text

120VAC

AutoCAD SHX Text

120VAC

AutoCAD SHX Text

120VAC

AutoCAD SHX Text M701

AutoCAD SHX Text

AutoCAD SHX Text M701

AutoCAD SHX Text

AutoCAD SHX Text M701

AutoCAD SHX Text

AutoCAD SHX Text M701

AutoCAD SHX Text

AutoCAD SHX Text M701

AutoCAD SHX Text

AutoCAD SHX Text M701

AutoCAD SHX Text

AutoCAD SHX Text M701

AutoCAD SHX Text

AutoCAD SHX Text

SA

AutoCAD SHX Text

RA

AutoCAD SHX Text

OA

AutoCAD SHX Text

OA

AutoCAD SHX Text

RA

AutoCAD SHX Text

SA

AutoCAD SHX Text

SA

AutoCAD SHX Text

RA

AutoCAD SHX Text

OA

AutoCAD SHX Text

SA

AutoCAD SHX Text

RA

AutoCAD SHX Text

APPROX 60°F @925 CFM

AutoCAD SHX Text

225 CFM

AutoCAD SHX Text

APPROX 60°F @700 CFM

AutoCAD SHX Text

300 CFM

AutoCAD SHX Text

150 CFM

AutoCAD SHX Text

150 CFM

AutoCAD SHX Text

200 CFM

AutoCAD SHX Text

100 CFM

AutoCAD SHX Text

160 CFM

AutoCAD SHX Text

360 CFM

AutoCAD SHX Text

260 CFM

AutoCAD SHX Text

300 CFM

AutoCAD SHX Text

200 CFM

AutoCAD SHX Text

AutoCAD SHX Text

114 CFM

AutoCAD SHX Text

114 CFM

AutoCAD SHX Text

100 CFM

AutoCAD SHX Text

950 CFM

AutoCAD SHX Text

1000-1300CFM

AutoCAD SHX Text

376 CFMX2

AutoCAD SHX Text

200 CFM

AutoCAD SHX Text

100 CFM

AutoCAD SHX Text

114 CFM

AutoCAD SHX Text E.A.

AutoCAD SHX Text

80 CFM

AutoCAD SHX Text

RM 231

AutoCAD SHX Text

RM 230

AutoCAD SHX Text

RM 229

AutoCAD SHX Text

RM 229A

AutoCAD SHX Text T.A.

AutoCAD SHX Text

80 CFM

AutoCAD SHX Text

80 CFM

AutoCAD SHX Text M701

MECHANICAL CONTROLS

I

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

POC: Aslam Husain

Wm S. Middleton, Madison, WI

607-19-115

Project Director

Revisions: Date:

9245 Calumet Ave. Suite 205, Phone: (219) 836-2120 Fax: (219) 836-1129 Munster, IN 46321

12.11.20

RELOCATE ELECTRON

MICROSCOPE

B

A

C

G

D

Schematic Design Documents 6.4.2020 Design Development 7.30.2020 65% Construction Documents 9.14.2020 95% Construction Documents 10.29.2020 100% Construction Documents 12.11.2020

GENERAL DEMOLITION NOTES:

DEMO PLAN NOTES

PD100

7 7

8 8

888 8

8 8

10 10

10 10

1 3

1 3

36C25221R0070 Attachment 11

AutoCAD SHX Text

DG201

AutoCAD SHX Text

DG284

AutoCAD SHX Text

DG282

AutoCAD SHX Text

DG202

AutoCAD SHX Text A31

AutoCAD SHX Text A16

AutoCAD SHX Text A32

AutoCAD SHX Text A28

AutoCAD SHX Text A33

AutoCAD SHX Text A33A

AutoCAD SHX Text

DG405

AutoCAD SHX Text

DG421

AutoCAD SHX Text

DG407

AutoCAD SHX Text

DG422

AutoCAD SHX Text

DG418

AutoCAD SHX Text

DG423

AutoCAD SHX Text

DG420

AutoCAD SHX Text

DG424

AutoCAD SHX Text A18

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

GG

AutoCAD SHX Text C

AutoCAD SHX Text A26B

AutoCAD SHX Text

ROOM

AutoCAD SHX Text A25

AutoCAD SHX Text

ROOM

AutoCAD SHX Text A24

AutoCAD SHX Text

ROOM

AutoCAD SHX Text A23

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

EX. FP

AutoCAD SHX Text

EX. 5" FP

AutoCAD SHX Text

EX. SPRINKLER - TYP.

AutoCAD SHX Text

EX. TUNNEL WALL-INTERIOR

AutoCAD SHX Text

A-WING GROUND PLUMBING PLUMBING DEMOLITION PLAN

AutoCAD SHX Text

-PLUMBING DEMOLITION

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

PLAN NORTH

AutoCAD SHX Text

A WING GROUND

AutoCAD SHX Text N

AutoCAD SHX Text

KEY PLAN

AutoCAD SHX Text Not to Scale

AutoCAD SHX Text

DG-249, 2ND FLR ROOF

AutoCAD SHX Text A23,A24,A25,A26B

AutoCAD SHX Text

A WING GROUND

AutoCAD SHX Text

D WING

AutoCAD SHX Text

AND 8TH FLOOR MECHANICAL D8201

AutoCAD SHX Text

D WING FUME HOOD CHASE

AutoCAD SHX Text

& 3RD FLOOR

AutoCAD SHX Text

DB1-229,230,231,232

AutoCAD SHX Text 1'

AutoCAD SHX Text 12"

AutoCAD SHX Text

AutoCAD SHX Text 5'

AutoCAD SHX Text 10'

AutoCAD SHX Text 20'

AutoCAD SHX Text

1. ALL WASTE PIPING INDICATED TO BE REMOVED IS LOCATED IN ALL WASTE PIPING INDICATED TO BE REMOVED IS LOCATED IN PIPE TUNNEL OR SLAB ON GRADE CONDITIONS BELOW. 2. ALL WASTE PIPING WHICH ARE BEING DEMOLISHED SHALL BE ALL WASTE PIPING WHICH ARE BEING DEMOLISHED SHALL BE REMOVED AND CAPPED WITH STEEL COVER AT FLOOR LEVEL SLAB. VERIFY CONNECTIONS FOR NEW MECHANICAL EQUIPMENT DRAINS. ALL VENT AND DOMESTIC WATER ABOVE CEILING SHALL BE CAPPED AT MAIN DISTRIBUTION PIPING. 3. EXISTING SINKS TO BE REMOVED. CAP PLUMBING PIPING AT EXISTING SINKS TO BE REMOVED. CAP PLUMBING PIPING AT NEAREST MAIN. CONTRACTOR TO FIELD VERIFY. SEE GENERAL NOTE 3 FOR ABATEMENT. 4. EXISTING EYE WASH WITH SHOWER TO BE REMOVED. EXISTING EYE WASH WITH SHOWER TO BE REMOVED. 5. EXISTING PIPING SERVICING OTHER FLOORS SHALL BE EXISTING PIPING SERVICING OTHER FLOORS SHALL BE MAINTAINED. CUT AND CAP AT CHILLER SOURCE. 6. ALL KNOWN, DE-IONIZED WATER, LAB GAS, VACUUM AND AIR TO ALL KNOWN, DE-IONIZED WATER, LAB GAS, VACUUM AND AIR TO LABORATORY HOSE BARBS AT HOODS SHALL BE ISOLATED AND CAPPED AT NEAREST MAIN DISTRIBUTION PIPING. CONTRACTOR TO FIELD VERIFY FEEDER THROUGH FLOOR SLAB BELOW OR IN WALL TO CEILING ABOVE. 7. REMOVE SIDE WALL SPRINKLER HEADS AND RECONFIGURE TO REMOVE SIDE WALL SPRINKLER HEADS AND RECONFIGURE TO NEW CEILING AS REQUIRED. 8. REMOVE ALL EXISTING LAB COUNTER MOUNTED HOSE BARBS. REMOVE ALL EXISTING LAB COUNTER MOUNTED HOSE BARBS. 9. REMOVE ALL ASSOCIATED WATER AND GAS PIPING TO DISTILLED REMOVE ALL ASSOCIATED WATER AND GAS PIPING TO DISTILLED WATER SYSTEM MOUNTED ON THE WALL 10. COORDINATE ABOVE CEILING FIRE PROTECTION WORK AND DEMO COORDINATE ABOVE CEILING FIRE PROTECTION WORK AND DEMO SPRINKLER HEADS TO RELOCATE TO NEW CEILING GRID AS REQUIRED.

1. CONTRACTOR SHALL COORDINATE ALL RISER SHUT-DOWNS WITH CONTRACTOR SHALL COORDINATE ALL RISER SHUT-DOWNS WITH THE VA. 2. CONTRACTOR SHALL COORDINATE ALL NEW RISER VALVE CONTRACTOR SHALL COORDINATE ALL NEW RISER VALVE LOCATIONS WITH THE VA. 3. COORDINATE WITH ABATEMENT DRAWINGS FOR DOMESTIC COORDINATE WITH ABATEMENT DRAWINGS FOR DOMESTIC PLUMBING EXTENT BELOW COUNTERS THAT MAY REQUIRE REMEDIATION OF PLUMBING FITTINGS. 4. COORDINATE DEMO WORK WITH DRAINS FOR NEW MECHANICAL COORDINATE DEMO WORK WITH DRAINS FOR NEW MECHANICAL EQUIPMENT DRAIN CONNECTIONS- SEE MECHANICAL PIPING PLAN.

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

POC: Aslam Husain

Wm S. Middleton, Madison, WI

607-19-115

Project Director

Revisions: Date:

9245 Calumet Ave. Suite 205, Phone: (219) 836-2120 Fax: (219) 836-1129 Munster, IN 46321

12.11.20

RELOCATE ELECTRON

MICROSCOPE

B

A

C

G

D

Schematic Design Documents 6.4.2020 Design Development 7.30.2020 65% Construction Documents 9.14.2020 95% Construction Documents 10.29.2020 100% Construction Documents 12.11.2020

GENERAL DEMOLITION NOTES:

DEMO PLAN NOTES

PD101

4 4 4

4 4

36C25221R0070 Attachment 11

AutoCAD SHX Text

DB1-229

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

DB1-230

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

DB1-232

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

DB1-228

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

DB1-231

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text 4"

AutoCAD SHX Text

EX. FD

AutoCAD SHX Text

EX. FD

AutoCAD SHX Text

EX. 6" FP

AutoCAD SHX Text

EX. 2" FP

AutoCAD SHX Text

4"V UP 4" W UP AND DN

AutoCAD SHX Text

MG OX MA MV DI

AutoCAD SHX Text

2" CW 3" HW

AutoCAD SHX Text 3/4"

AutoCAD SHX Text

EX. FD

AutoCAD SHX Text

EX. FD

AutoCAD SHX Text

EX. SPRINKLER - TYP.

AutoCAD SHX Text

EX. SINK

AutoCAD SHX Text 2"

AutoCAD SHX Text 2 1/2"

AutoCAD SHX Text 4"

AutoCAD SHX Text 2"

AutoCAD SHX Text 2"

AutoCAD SHX Text 2"

AutoCAD SHX Text 2 1/2"

AutoCAD SHX Text 4"

AutoCAD SHX Text

D-WING BASEMENT LEVEL 1 PLUMBING DEMOLITION PLAN

AutoCAD SHX Text

-PLUMBING DEMOLITION

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

PLAN NORTH

AutoCAD SHX Text

D WING BASEMENT LEVEL 1

AutoCAD SHX Text N

AutoCAD SHX Text

KEY PLAN

AutoCAD SHX Text Not to Scale

AutoCAD SHX Text

DG-249, 2ND FLR ROOF

AutoCAD SHX Text A23,A24,A25,A26B

AutoCAD SHX Text

A WING GROUND

AutoCAD SHX Text

D WING

AutoCAD SHX Text

AND 8TH FLOOR MECHANICAL D8201

AutoCAD SHX Text

D WING FUME HOOD CHASE

AutoCAD SHX Text

& 3RD FLOOR

AutoCAD SHX Text

DB1-229,230,231,232

AutoCAD SHX Text 1'

AutoCAD SHX Text 12"

AutoCAD SHX Text

AutoCAD SHX Text 5'

AutoCAD SHX Text 10'

AutoCAD SHX Text 20'

AutoCAD SHX Text ALL WASTE PIPING INDICATED TO REMAIN IS LOCATED IN CEILING OF FLOOR BELOW. ALL VENT AND DOMESTIC WATER PIPING ABOVE CEILING TO REMAIN. NEW PIPING TO POINT OF CONNECTION TO EXISTING PIPING IS REMAINING IN SERVICE. CONTRACTOR TO VERIFY IN FIELD. FLOOR DRAINS AND PIPE SLEEVES IN ROOM DB1-232 TO BE REMOVED. INFILL HOLES. CAP ABOVE CEILING OF LOWER FLOOR LEVEL DB2. COORDINATE ABOVE CEILING FIRE PROTECTION WORK AND DEMO SPRINKLER HEADS TO RELOCATE TO NEW CEILING GRID AS REQUIRED.

1. CONTRACTOR SHALL COORDINATE ALL RISER SHUT-DOWNS WITH CONTRACTOR SHALL COORDINATE ALL RISER SHUT-DOWNS WITH THE VA. 2. CONTRACTOR SHALL COORDINATE ALL NEW RISER VALVE CONTRACTOR SHALL COORDINATE ALL NEW RISER VALVE LOCATIONS WITH THE VA.

EQUIPMENT

DB1-229A

MICROSCOPE

ROOM

DB1-229

LAB

DB1-231

OFFICE

DB1-232

CHILLER

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

POC: Aslam Husain

Wm S. Middleton, Madison, WI

607-19-115

Project Director

Revisions: Date:

9245 Calumet Ave. Suite 205, Phone: (219) 836-2120 Fax: (219) 836-1129 Munster, IN 46321

12.11.20

RELOCATE ELECTRON

MICROSCOPE

B

A

C

G

D

Schematic Design Documents 6.4.2020 Design Development 7.30.2020 65% Construction Documents 9.14.2020 95% Construction Documents 10.29.2020 100% Construction Documents 12.11.2020

NEW PLAN NOTES

PL101

36C25221R0070 Attachment 11

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text

MG OX MA MV DI

AutoCAD SHX Text

2" CW 3" HW

AutoCAD SHX Text 3/4"

AutoCAD SHX Text

NEW DI

AutoCAD SHX Text

NEW DI

AutoCAD SHX Text P-1

AutoCAD SHX Text P-707

AutoCAD SHX Text

FD-1

AutoCAD SHX Text

TMV

AutoCAD SHX Text P-414

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

FD-2

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 4"

AutoCAD SHX Text

4"V UP 4" W UP AND DN

AutoCAD SHX Text 2"

AutoCAD SHX Text 2 1/2"

AutoCAD SHX Text

4" W DN

AutoCAD SHX Text 4"

AutoCAD SHX Text 2"

AutoCAD SHX Text 2"

AutoCAD SHX Text 2"

AutoCAD SHX Text 2 1/2"

AutoCAD SHX Text 4"

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text NEW PLAN NOTES: 1. ALL WASTE PIPING INDICATED TO BE RETAINED IS ALL WASTE PIPING INDICATED TO BE RETAINED IS LOCATED IN CEILING OF FLOOR BELOW. 2. INSTALL NEW COUNTER SINK P-1 INSTALL NEW COUNTER SINK P-1 P-1 3. INSTALL NEW WALL LAVATORY SINK P-414 INSTALL NEW WALL LAVATORY SINK P-414 P-414 4. INSTALL NEW EYE WASH WITH SHOWER P-707 INSTALL NEW EYE WASH WITH SHOWER P-707 P-707 AND ASSOCIATED TMV VALVE AND FLOOR DRAIN FD-1 5. INSTALL ALL WASTE, VENT AND DOMESTIC WATER INSTALL ALL WASTE, VENT AND DOMESTIC WATER PIPING SERVING NEW FIXTURES FROM POINT OF CONNECTION TO EXISTING PIPING WHICH IS REMAINING IN SERVICE. CONTRACTOR TO VERIFY IN FIELD. 6. INSTALL NEW WATER SUPPLY FOR RELOCATED INSTALL NEW WATER SUPPLY FOR RELOCATED CHILLER. INSTALL NEW FLOOR DRAIN FD-2. FD-2. . 7. INSTALL DEINOZIED WATER FROM EXISTING INSTALL DEINOZIED WATER FROM EXISTING SOURCE FOR SINK CONNECTIONS

AutoCAD SHX Text P-1

AutoCAD SHX Text P-707

AutoCAD SHX Text P-414

AutoCAD SHX Text

LAVATORY

AutoCAD SHX Text

COUNTER SERVICE SINK

AutoCAD SHX Text

EMERGENCY EYE WASH W/SHOWER

AutoCAD SHX Text

SEE SPECIFICATION 22-40-00

AutoCAD SHX Text

PLUMBING FIXTURE SCHEDULE

AutoCAD SHX Text

PIPING SIZE REQ.

AutoCAD SHX Text

CW

AutoCAD SHX Text

HW

AutoCAD SHX Text

VENT

AutoCAD SHX Text

WASTE

AutoCAD SHX Text 3/4"

AutoCAD SHX Text 3/4"

AutoCAD SHX Text 1 1/2"

AutoCAD SHX Text 1 1/2"

AutoCAD SHX Text 3/4"

AutoCAD SHX Text 3/4"

AutoCAD SHX Text 1 1/2"

AutoCAD SHX Text 1 1/2"

AutoCAD SHX Text 1 1/4"

AutoCAD SHX Text 1 1/4"

AutoCAD SHX Text

THERMOSTATIC MIXING VALVE

AutoCAD SHX Text

NOTE 2

AutoCAD SHX Text

AutoCAD SHX Text

NOTE 2

AutoCAD SHX Text

TMV

AutoCAD SHX Text

FIXTURE DESCRIPTION

AutoCAD SHX Text

FIXTURE

AutoCAD SHX Text

AutoCAD SHX Text PLUMBING FIXTURE SCHEDULE NOTES: 1. FOR COUNTER SERVICE SINK DETAILS AND DESCRIPTIONS, FOR COUNTER SERVICE SINK DETAILS AND DESCRIPTIONS, REFERENCE SPECIFICATION 12-36-00 AND 22-40-00. 2. FOR FIXTURES DETAILS AND DESCRIPTIONS, REFERENCE FOR FIXTURES DETAILS AND DESCRIPTIONS, REFERENCE SPECIFICATION 22-40-00. 3. FLOOR DRAIN DESCRIPTIONS: REFERENCE SPECIFICATION 22 13 FLOOR DRAIN DESCRIPTIONS: REFERENCE SPECIFICATION 22 13 00 FOR SPECIFIC REQUIREMENTS

AutoCAD SHX Text

NOTE 1

AutoCAD SHX Text

NOTES

AutoCAD SHX Text

NOTE 2

AutoCAD SHX Text GENERAL NOTES: 1. ALL WASTE PIPING INDICATED IS LOCATED IN CEILING OF FLOOR ALL WASTE PIPING INDICATED IS LOCATED IN CEILING OF FLOOR BELOW. 2. CONTRACTOR SHALL VERIFY THE SIZES OF ALL EXISTING PIPING CONTRACTOR SHALL VERIFY THE SIZES OF ALL EXISTING PIPING THAT ARE NOTED FOR NEW CONNECTIONS. 3. CONTRACTOR SHALL COORDINATE ALL RISER SHUT-DOWNS WITH CONTRACTOR SHALL COORDINATE ALL RISER SHUT-DOWNS WITH THE VA. 6. RE-HANG EXISTING HORIZONTAL SUSPENDED WATER AND VENT PIPING THAT IS TO REMAIN, AND IS CURRENTLY SUPPORTED OR LAYING ON THE CEILING SYSTEM SUPPORT GRID. REFER TO THE SPECS FOR CORRECT HANGER AND SUPPORT DEVICES, MATERIALS AND WORKMANSHIP. 7. REFER TO HITACHI CHILLER MANUFACTURER DOCUMENTS FOR REFER TO HITACHI CHILLER MANUFACTURER DOCUMENTS FOR PLUMBING TO BE INTEGRATED INTO THE EQUIPMENT.

AutoCAD SHX Text

CLAMP

AutoCAD SHX Text

FLASHING

AutoCAD SHX Text

DB1-229A

AutoCAD SHX Text

LOCATION

AutoCAD SHX Text

TAG NO.

AutoCAD SHX Text F

AutoCAD SHX Text

TYPE

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text C.I.

AutoCAD SHX Text

BODY

AutoCAD SHX Text N.B.

AutoCAD SHX Text

TOP

AutoCAD SHX Text

STRAINER

AutoCAD SHX Text

DRAIN SCHEDULE - PLUMBING FIXTURE SCHEDULE - NOTE 3

AutoCAD SHX Text

J.R. SMITH 2010-B-NB-50

AutoCAD SHX Text

MISC.

AutoCAD SHX Text

YES

AutoCAD SHX Text

MODEL NO.

AutoCAD SHX Text

NOTE: PROVIDE FLASHING FOR ALL DRAINS INSTALLED ABOVE GRADE.

AutoCAD SHX Text

AREAS

AutoCAD SHX Text

LAB DB1-231

AutoCAD SHX Text

FD-1

AutoCAD SHX Text F

AutoCAD SHX Text N.B.

AutoCAD SHX Text C.I.

AutoCAD SHX Text 8"X8" N.B.

AutoCAD SHX Text

J.R. SMITH 2010-B-H-NB-50

AutoCAD SHX Text

YES

AutoCAD SHX Text

PROVIDE SQUARE STRAINER

AutoCAD SHX Text

FD-2

AutoCAD SHX Text

PROVIDE SQUARE STRAINER

AutoCAD SHX Text 8"X8" N.B.

AutoCAD SHX Text

D-WING BASEMENT LEVEL 1 PLUMBING NEW WORK PLAN

AutoCAD SHX Text

-PLUMBING NEW WORK

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

PLAN NORTH

AutoCAD SHX Text

D WING BASEMENT LEVEL 1

AutoCAD SHX Text N

AutoCAD SHX Text

KEY PLAN

AutoCAD SHX Text Not to Scale

AutoCAD SHX Text

DG-249, 2ND FLR ROOF

AutoCAD SHX Text A23,A24,A25,A26B

AutoCAD SHX Text

A WING GROUND

AutoCAD SHX Text

D WING

AutoCAD SHX Text

AND 8TH FLOOR MECHANICAL D8201

AutoCAD SHX Text

D WING FUME HOOD CHASE

AutoCAD SHX Text

& 3RD FLOOR

AutoCAD SHX Text

DB1-229,230,231,232

AutoCAD SHX Text 1'

AutoCAD SHX Text 12"

AutoCAD SHX Text

AutoCAD SHX Text 5'

AutoCAD SHX Text 10'

20'

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

POC: Aslam Husain

Wm S. Middleton, Madison, WI

607-19-115

Project Director

Revisions: Date:

9245 Calumet Ave. Suite 205, Phone: (219) 836-2120 Fax: (219) 836-1129 Munster, IN 46321 PL500

36C25221R0070 Attachment 11

AutoCAD SHX Text

%%ULAVATORY MOUNTING DETAIL

AutoCAD SHX Text

VARIES

AutoCAD SHX Text 1/4"

AutoCAD SHX Text

%%UPLAN

AutoCAD SHX Text

%%UNOTE:

AutoCAD SHX Text 1.

AutoCAD SHX Text

PROVIDE 20 GAGE STUDS WHEN HEIGHT

AutoCAD SHX Text

EXCEEDS 12'-0" (3.7 M)

AutoCAD SHX Text

%%USECTION

AutoCAD SHX Text

STEEL WALL CARRIER

AutoCAD SHX Text

STUDS

AutoCAD SHX Text

%%UTYPE F FLOOR DRAIN (FD-1 & 2) DETAIL

AutoCAD SHX Text

SEAMLESS VINYL FLOOR

AutoCAD SHX Text

WEEP HOLES

AutoCAD SHX Text

LOOSE GRAVEL AT WEEP HOLES

AutoCAD SHX Text

ADJUSTABLE TWO PIECE NICKEL BRONZE

AutoCAD SHX Text

FLASHING STRAINER WITH 9"%%C FLANGE

AutoCAD SHX Text

FLASHING -MIN. 24" (600 MM)

AutoCAD SHX Text

PROVIDE A METAL SUPPORT PLATE WHEN DRAIN IS

AutoCAD SHX Text

CAULKED, NO-HUB OR

AutoCAD SHX Text

THREADED CONNECTION

AutoCAD SHX Text

INSTALLED IN AN EXISTING FLOOR- CAULK AROUND DRAIN

AutoCAD SHX Text

SQUARE 2 1/2 LB. (1.1 KG) TO

AutoCAD SHX Text

4 LB. (1.8 KG) LEAD OR

AutoCAD SHX Text

16 OZ. (453 G) COPPER

AutoCAD SHX Text

PROVIDE FLASHING WHEN DRAIN IS INSTALLED IN A NON MEMBRANE FLOOR

AutoCAD SHX Text

%%UNOTE:

AutoCAD SHX Text

FD

AutoCAD SHX Text

34"REDUCER

AutoCAD SHX Text

34" PVC PIPE

AutoCAD SHX Text

FD

AutoCAD SHX Text

34"REDUCER

AutoCAD SHX Text

SEAMLESS VINYL FINISH FLOOR

AutoCAD SHX Text

%%UPEDESTAL MOUNTED EYE WASH-FOR TESTING

AutoCAD SHX Text

%%UPEDESTAL MOUNTED EYE WASH-NORMAL POSITION

AutoCAD SHX Text

PROVIDE J.R.SMITH HINGED GRATE ON EYE WASH FLOOR DRAIN FD-1- CLOSED POSITION

AutoCAD SHX Text

PROVIDE J.R.SMITH HINGED GRATE ON EYE WASH FLOOR DRAIN FD-1-OPEN POSITION

AutoCAD SHX Text

PRIOR TO RE-GROUTING

AutoCAD SHX Text

SEAMLESS VINYL FINISH FLOOR

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

%%UTYPICAL LAVATORY PIPING DETAIL

AutoCAD SHX Text

NEW FAUCET

AutoCAD SHX Text

CHROME PLATED 3/8" COPPER

AutoCAD SHX Text

THREADED LOOSE KEY SUPPLY STOP

AutoCAD SHX Text

THREADED LOOSE KEY SUPPLY STOP

AutoCAD SHX Text

P-TRAP

AutoCAD SHX Text

WASTE WALL BEND INTO WALL WITH ESCUTCHEON

AutoCAD SHX Text COMMERCIAL GRADE, HEAVY DUTY, CONCEALED, ADJUSTABLE, FLOOR MOUNTED WITH SHORT FEET FOR THIN WALL CONSTRUCTION, SEE SPECIFICATION 22 40 00 2.6. ZURN Z1231EZ-WL OR Z1231-EZ OF APPROVED EQUAL

AutoCAD SHX Text

34" PVC PIPE

PLUMBING DETAILS

SAFETY OFFICE

A26

SAFETY OFFICE

A26A

COMPUTER LAB

A24

EQUIPMENT

DB1-229A

MICROSCOPE

ROOM

DB1-229

LAB

DB1-231

OFFICE

DB1-232

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

POC: Aslam Husain

Wm S. Middleton, Madison, WI

607-19-115

Project Director

Revisions: Date:

9245 Calumet Ave. Suite 205, Phone: (219) 836-2120 Fax: (219) 836-1129 Munster, IN 46321

12.11.20

RELOCATE ELECTRON

MICROSCOPE

B

A

C

G

D

Schematic Design Documents 6.4.2020 Design Development 7.30.2020 65% Construction Documents 9.14.2020 95% Construction Documents 10.29.2020 100% Construction Documents 12.11.2020

NEW PLAN NOTES

EQUIPMENT NOTES

NO DESCRIPTION

1 SPRINKLER STAND PIPE HEADS - 1" CONNECTIONS - CHROME

SEMI-RECESS QUICK RESPONSE TYPE

2 PIPING AND FITTINGS SHALL BE IN ACCORDANCE WITH NFPA 14. BLACK

STEEL, SCHEDULE 10 MINIMUM.

3 PIPE HANGERS AND SUPPORTS TO CONFORM TO NFPA 14.

4 WET SYSTEM CONTROL VALVE SHALL BE UL LISTED AN FM APPROVED FOR

FIRE PROTECTION INSTALLATIONS WITH MINIMUM 175 PSIG RATING.

5. SPRINKLER HEADS TO BE QUICK RESPONSE TYPE.

NOTES

1. CONTRACTOR SHALL DESIGN, PROCURE, CONSTRUCT AND COMMISSION

AN INTEGRATED FIRE PROTECTION SYSTEM IN PER THE LISTED

SPECIFICATIONS AND GENERAL INTENTION OF SERVING A HOSPITAL

BUILDING IN COMPLIANCE WITH ALL NFPA CODES AND LOCAL

REQUIREMENTS INCLUDING BUT NOT LIMITED TO THE FOLLOWING:

A. HAZARD CLASSIFICATION OF THE BUILDING AND

SPECIFIC AREAS BASED ON ARCHITECTURAL DRAWINGS.

FOR DUAL USE OR MULTI-ROLE AREAS USE STRICTER

OF THE APPLICABLE CLASSIFICATIONS.

B. SPRINKLER, TESTING AND DRAIN PIPING INCLUDING

FLOW SWITCHES, ISOLATION VALVES, TAMPER SWITCH,

PRESSURE GAUGE AND OTHER COMPONENTS.

C. FIRE EXTINGUISHER CABINETS (FEC)TO BE PROVIDED IN EXISTING

SPACES AS SHOWN ON THE DRAWINGS.

D. IDENTIFICATION SIGNS AND HYDRAULIC PLACARDS PER

NFPA 14.

E. FREEZE PROTECTION FEATURES SHALL BE

INCORPORATED AS REQUIRED.

F. FIRE ALARM AND ANNUNCIATION SYSTEM SHOWN ON

FA-100.

2. ALL ATTEMPTS TO IDENTIFY EXISTING SPRINKLER DISTRIBUTION AS

SHOWN HAS BEEN MADE TO THE BEST OF THE A/E OF KNOWN SITE

FIELD CONDITIONS AND AS BUILTS. CONTRACTOR TO REVIEW DEFINED

ZONES, SPRINKLER LOCATIONS, EXISTING PIPING MAIN AND BRANCHES,

PIPE SIZES INDICATED WITHIN RENOVATION ZONE TO BE

REDISTRIBUTED INTO NEW LAYOUT AND CEILING GRID AND MAKE

ADJUSTMENTS AS NECESSARY TO COMPLETE THE REQUIRED PER

REGULATIONS AND SPECIFICATIONS.

3. DESIGN OF SPRINKLER SYSTEM AND SHOP DRAWINGS SHALL BE

COMPLETED BY A LICENSED ENGINEER PRACTICING IN THE FIELD OF

FIRE PROTECTION ENGINEERING

4. INSTALLER SHALL POSSESS A VALID STATE CONTRACTOR'S LICENSE

AND BE TRAINED IN WET SYSTEM FIRE PROTECTION INSTALLATIONS.

5. ALL EQUIPMENT AND DEVICES SHALL BE OF A MAKE AND TYPE LISTED

BY UL AND APPROVED BY FM

6. DESIGN, MATERIALS, EQUIPMENT, INSTALLATION AND TESTING OF THE

SYSTEM SHALL BE IN ACCORDANCE WITH NFPA 13.

7. CONTRACTOR SHALL PROCURE, CONSTRUCT AND COMMISSION

INTEGRATED FIRE PROTECTION SYSTEM.

8. CONTRACTOR SHALL PROVIDE AND SUBMIT HYDRAULIC CALCULATIONS

USING THE MAIN WATER PRESSURE AND FLOW RATE PER NFPA 13.

REFER TO SPEC SECTION 21-13-13.

9. ALL EXISTING FIRE PROTECTION SPRINKLERS ARE TO REMAIN IN

SERVICE TO PROVIDE FOR THE BUILDING AND EXISTING LABORATORY

AND HOSPITAL FUNCTIONS. SHUTDOWN BE COORDINATED WITH VA.

APPROVAL IN WRITING MUST BE OBTAINED FROM THE VA'S

REPRESENTATIVE FOUR (4) WEEKS IN ADVANCE.

36C25221R0070 Attachment 11

AutoCAD SHX Text

DG201

AutoCAD SHX Text

DG202

AutoCAD SHX Text A31

AutoCAD SHX Text

DG421

AutoCAD SHX Text

DG407

AutoCAD SHX Text

DG422

AutoCAD SHX Text

DG418

AutoCAD SHX Text

DG423

AutoCAD SHX Text

DG420

AutoCAD SHX Text

DG424

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EX. 6" FP

AutoCAD SHX Text

EX. 2" FP

AutoCAD SHX Text

EX. SPRINKLER

AutoCAD SHX Text

EX. 2" FP

AutoCAD SHX Text

EX. FP

AutoCAD SHX Text N

AutoCAD SHX Text

KEY PLAN

AutoCAD SHX Text Not to Scale

AutoCAD SHX Text

DG-249, 2ND FLR ROOF

AutoCAD SHX Text A23,A24,A25,A26B

AutoCAD SHX Text

A WING GROUND

AutoCAD SHX Text

D WING

AutoCAD SHX Text

AND 8TH FLOOR MECHANICAL D8201

AutoCAD SHX Text

D WING FUME HOOD CHASE

AutoCAD SHX Text

& 3RD FLOOR

AutoCAD SHX Text

DB1-229,230,231,232

AutoCAD SHX Text

FP100

AutoCAD SHX Text

AWING AND DWING - FIRE PROTECTION NEW WORK PLAN

AutoCAD SHX Text 12"

AutoCAD SHX Text

AutoCAD SHX Text 1'

AutoCAD SHX Text 5'

AutoCAD SHX Text 10'

AutoCAD SHX Text 20'

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text

AWING GROUND PLAN - FIRE PROTECTION COVERAGE PLAN

AutoCAD SHX Text

AutoCAD SHX Text N

AutoCAD SHX Text 12"

AutoCAD SHX Text

AutoCAD SHX Text 1'

AutoCAD SHX Text 5'

AutoCAD SHX Text 10'

AutoCAD SHX Text 20'

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text

DWING BASEMENT PLAN - FIRE PROTECTION COVERAGE PLAN

AutoCAD SHX Text

AutoCAD SHX Text N

AutoCAD SHX Text

GENERAL OFFICE

AutoCAD SHX Text

LAB AND ELECTRON MICROSCOPE ROOM

AutoCAD SHX Text ADJUST EXISTING SPRINKLER HEADS PIPE OFFSETS IN CEILING FOR NEW CEILING HEIGHTS AND CENTER IN NEW CEILING TILES INSTALL NEW SPRINKLER HEADS IN CEILING FOR NEW CEILING HEIGHTS AND REDISTRIBUTION OF PIPING FOR APPLICABLE COVERAGE REQUIREMENTS. CENTER IN NEW CEILING TILES CAP EXISTING AS REQUIRED TO ADD TO NEW ZONE.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ELECTRICAL SYMBOLS - NEW

MOUNTING HEIGHT SCHEDULE

DEVICE MOUNTING HEIGHT

SWITCHES 48-INCH TOP

RECEPTACLE AND TELECOMMUNICATION:

48-INCH TOP

IN JANITOR CLOSETS, EQUIPMENT

ROOM, STORAGE ROOM, SHOP

TOILETS AND UNFINISHED AREAS

RECEPTACLE AND TELECOMMUNICATION:

24-INCH BOTTOM

WEATHERPROOF (EXTERIOR)

RECEPTACLE AND TELECOMMUNICATION:

16-INCH BOTTOM

OTHER LOCATIONS

RECEPTACLE AND TELECOMMUNICATION:

BOTTOM 2-INCHES ABOVE BACKSPLASH

AT COUNTERS AND DESK

FIRE ALARM, HORNS AND VISUALS UNITS BOTTOM OF UNIT 80-INCHES ABOVE FINISHED

FLOOR

CLOCKS, SPEAKERS, ETC. TOP OF UNIT 2-INCHES BELOW CEILING OR

96-INCHES (WHICHEVER IS LOWER)

THERMOSTATS, STARTERS, SPEAKER

48-INCH TOPCONTROLS, FIRE ALARM MANUAL STATIONS,

WALL PHONES, ETC.

NOTES:

THE MOUNTING HEIGHT SCHEDULE IS INCLUDED TO ASSIST THE CONTRACTOR IN

ESTIMATING. HEIGHTS LISTED ARE ABOVE FINISHED FLOOR UNLESS OTHERWISE NOTED.

ALL DEVICE LOCATIONS SHALL BE COORDINATED WITH ARCHITECTURAL DETAILS AND

ELEVATIONS. EXACT HEIGHTS SHALL BE OBTAINED FROM THE VA COR.COMMUNICATION SYMBOLS-NEW

SWITCHES

RECEPTACLES

FIRE ALARM SYSTEM -NEW

SECURITY SYSTEMS - NEW

LIGHTING -NEW

POWER

ELECTRICAL SYMBOLS AND ABBR.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

POC: Aslam Husain

Wm S. Middleton, Madison, WI

607-19-115

Project Director

Revisions: Date:

9245 Calumet Ave. Suite 205, Phone: (219) 836-2120 Fax: (219) 836-1129 Munster, IN 46321

12.11.20

RELOCATE ELECTRON

MICROSCOPE

Schematic Design Documents 6.4.2020 Design Development 7.30.2020 65% Construction Documents 9.14.2020 95% Construction Documents 10.29.2020 100% Construction Documents 12.11.2020

E001

F X

F

SP

SHOWN TO BE REMOVED OR RETAINES

36C25221R0070 Attachment 11

AutoCAD SHX Text LIGHT FIXTURE, RECESSED MOUNT LED, 2'x4'; LETTER INDICATES TYPE.

AutoCAD SHX…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .