S02 Salem Facility Wide Security Camera Upgrade Drawings 31-40.pdf

PDF 5 MB Posted

Attached to
Z1DA--Facility Wide Security Camera Upgrades Federal contract opportunity
Solicitation number
36C24623B0019
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6

About this file

This is a solicitation for a facility-wide security camera upgrade project at the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6. The project involves installing new security cameras at multiple buildings and parking lots at the Salem VA Medical Center campus. Key details include the requirement for IP-based cameras and associated equipment from Avigilon, with fiber optic cabling for runs over 295 feet. The contractor must coordinate all work with the Contracting Officer Representative and minimize any disruption to existing surveillance. The period of performance is one year from NTP.

View the file

Other files for this federal contract opportunity

Other files attached to Z1DA--Facility Wide Security Camera Upgrades, newest first.
File Type Posted
36C24623B0019 0004_1.docx DOCX document
S05 36C24623B0019 Facility Wide Security Camera Upgrade Questions 3-20-2023.pdf PDF
S06 36C24623B0019 0004.pdf PDF
S06_36C24623B0019 0003.pdf PDF
36C24623B0019 0003_1.docx DOCX document
S02_ 0002_36C24623B0019 0002.pdf PDF
36C24623B0019 0002_1.docx DOCX document
36C24623B0019 0001_1.docx DOCX document
S06_36C24623B0019 0001.pdf PDF
S02 Salem Facility Wide Security Camera Upgrade Drawings 21-30.pdf PDF
S02 Salem Facility Wide Security Camera Upgrade Drawings1-10.pdf PDF
S02 Salem Facility Wide Security Camera Upgrade Specs.pdf PDF
S02 36C24623B0019_1 Fac. Wide Cameras.pdf PDF
S02 Salem Facility Wide Security Camera Upgrade Drawings11-20.pdf PDF
36C24623B0019_2.docx DOCX document
Show all 15

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CHASE

FP

FP

ELECTRICAL

STORAGE

LOCKSMITH

OFFICE

15A

15B

15D

CARPENTRY SHOP

BREAK RM

15C

STORAGE

2A

STORAGE

2B

LOUNGE

SD4B-76

ELECTRICAL SHOP

OFFICE

4A

IT

STORAGE

CARPENTRY

STORAGE

UTILITY

RM

STORAGE

10B1010A

WOMENS

TOILET

9A

ELECTRONIC SHOP

9ELECTRIC STORAGE

MULTI PURPOSE

5A

SIGN SHOP

6A

STORAGE

5B

ELEVATOR STORAGE

1A

CORRIDOR

CORRIDOR

CORR.

CORRIDOR

STAIR

STAIR

LOCKSMITH

STORAGE

1C

ELECTRICAL SHOP

MECHANICAL

EXISTING PANEL -

PANEL '76-BS1'

'76-BS1' - 1

VA PROJECT NUMBER

Building Number

Drawing Number

Project Title

Date Checked Drawn

Drawing Title

Approved:

VA FORM 08-6231

A

B C

D E

21 4 5 6 7

321 4 5 6 7

A B

C E

Dwg. of

LocationLocation

Office of Construction and Facilities Management

PROJECT MANAGER: ACG Project Number

Revisions: Date

CONSULTANTS:

OCTOBER 24, 2022 ADRKTK

658-20-10520-210

CONSTRUCTION DOCUMENTS - FOR CONSTRUCTION

FULLY SPRINKLERED

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A. 34Engineers Architects

U.S. Department of Veterans Affairs

FACILITY WIDE SECURITY

CAMERAS UPGRADE

SALEM VA MEDICAL CENTER

1970 ROANOKE BLVD.

SALEM, VA 24153

CAMERA SYMBOL LEGENDCAMERA SYMBOL LEGEND

SYMBOL HEIGHT DESCRIPTION

CCTV FISH EYE

(WP-WEATHER PROOF)

TYPE

12 MP

H4F-DO1-IR

5 MP H5A

24 MP

24C-H4A-3MH

CCTV FIXED DOME

(WP-WEATHER PROOF)

6 MP H5A

360 32 MP

32C-H4A-4MH

3 MP

H4 LPC

FE

MANUFACTURER

AVIGILON

TOTAL

DEVICES

AVIGILON

AVIGILON

AVIGILON

AVIGILON

AVIGILON

AVIGILON

CCTV FIXED DOME

(WP-WEATHER PROOF)

CCTV MULTISENSOR

(WP-WEATHER PROOF)

CCTV MULTISENSOR

(WP-WEATHER PROOF)

CCTV MULTISENSOR

(WP-WEATHER PROOF)

CCTV MULTISENSOR

(WP-WEATHER PROOF)

CCTV LICENSE PLATE

(WP-WEATHER PROOF)

24 MP

24C-H4A-3MH

24 MP

24C-H4A-3MH

D6

360L

CAMERA ABBREVIATIONS

N

RP

RV

WP

PROVIDE AND INSTALL NEW CAMERA

REPLACE EXISTING CAMERA WITH NEW CAMERA

REMOVE EXISTING CAMERA

WEATHER PROOF

SPECIAL NOTE

ALL CAMERAS LOCATED ON THE EXTERIOR OF THE

BUILDING ARE SHOWN ON SHEET TS101 UNLESS

NOTED OTHERWISE.

WALL RATINGS LEGEND:

SMOKE WALLS S S S

1 HOUR FIRE WALL

S

2 HOUR FIRE WALL

3 HOUR FIRE WALL

D5

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

AVIGILON

76TK101

BUILDING 76 BASEMENT FLOOR

SECURITY PLAN

1 BUILDING 76 BASEMENT FLOOR SECURITY PLAN

1/8" = 1'-0"

00 4 8 16

NORTH

SHEET NOTES:

SHEET KEY NOTES:X

A. NO INTERIOR CAMERAS TO BE REMOVED,

REPLACED, OR ADDED. REFERENCE SHEET

TS101 FOR EXTERIOR CAMERA LOCATIONS.

B. CCTV SERVICES ARE TO REMAIN ACTIVE

OUTSIDE AREAS UNDER ACTIVE CONSTRUCTION

AT ALL TIMES. RETAIN SERVICES TO SYSTEMS

DURING DEMOLITION AND REMODEL OF THE

RESPECTIVE AREAS.

C. ALL EXISTING CONDITIONS ARE BASED ON THE

BEST AVAILABLE INFORMATION AT THE TIME OF

SURVEY AND VISUAL INSPECTION. VERIFY

EXISTING CONDITIONS.

D. NEW CCTV CABLING TO BE RUN ON J-HOOKS 2'

OC ABOVE CEILING IN CORRIDORS.

E. ALL CONDUIT SECURITY JUNCTION BOXES AND

RACEWAY PROVIDED BY EC UNO. ALL CONDUIT

SHALL BE 3/4" MINIMUM. EC TO SIZE CONDUIT

PER THE MOST CURRENT EDITION OF THE NEC.

F. WHERE LENGTH FROM CAMERA TO RACK

EQUIPMENT EXCEED 295' (90M) CONTRACTOR

SHALL USE FIBER OPTIC CABLE AS ILLUSTRATED

IN DETAIL 7/T-502.

G. COORDINATE AND CONFIRM ALL ROUTING WITH

COR PRIOR TO ROUGH-IN.

1. EXISTING WALL MOUNTED PATCH PANELS AND

SWITCHES.

2. PROPOSED LOCATION FOR NEW PoE MID-SPAN

DEVICE AND NEW WALL MOUNTED SHELF. MOUNT

SHELF BELOW OTHER WALL MOUNTED

EQUIPMENT (COORDINATE LOCATION WITH COR

AND OIT REPRESENTATIVE). PROVIDE NEW,

FLOOR MOUNTED UPS CLOSE ENOUGH FOR PoE

MID-SPAN DEVICE TO PLUG INTO UPS.

COORDINATE WITH PoE MID-SPAN DEVICE

MANUFACTURER FOR POWER CORD LENGTH.

REFERENCE 2/T-602 FOR MORE INFORMATION.

3. PROVIDE POWER OUTLET FOR NEW CCTV

EQUIPMENT. INSTALL POWER OUTLET WITHIN 5

FEET OF NEW UPS LOCATION.

4. REMOVE EXISTING CAMERA FIELD DISTRIBUTION

BOX AND ENCODER. SURRENDER EQUIPMENT TO

THE POLICE.

5. PROVIDE NEW 1P, 20A CIRCUIT BREAKER IN

EXISTING PANEL FOR NEW RECEPTACLE IN IT

ROOM 21.

6. PROVIDE NEW 4", UL LISTED SLEEVE.

DocuSign Envelope ID: 3ADC3376-EFA9-4753-9EE8-D15D0B94D50D

10/26/2022

MECH

FP

CLOSET

13C

HOUSE KEEPING

FP

OFFICE

SUPPLIES

13P

STORAGE

13J

HC TOILET

12H

RECEPTION

12Q

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

EMS

OFFICE

OFFICE

OFFICE

8A

TOILET

9B

EMS

STORAGE

SOILED LINEN

BIO-HAZARD

9A

EMS

STORAGE

STAIR CORRIDOR

OFFICE

12A

LOAN

12B

RECORDS

12C

WORK RM

12D

OFFICE

12E

CHIEF

12F LOUNGE

12G

SUPPLIES

12J

ACCNT

12K

SHARE

DRAFT

12L

LOAN

12M

LOAN

12N

OFFICE

12P

MECH

12R

CORRIDOR

OFFICE

13A

OFFICE

NEW

ACCOUNTS

13B

HAC

13D

LOBBY

VESTIBULE

13E

TELLER AREA

13F

WORK RM

13H

WORK

RM

13K

HC TOILET

13M

EMS

OFFICE

15C

OFFICE

15D15E

OFFICE

15F

ELEVATOR

EMS STORAGE

TOILET

1AELEVATOR

SERVICE

RM

2C

GENERAL

EQUIPMENT

STORAGE

2A

EMS

STORAGE

PAINT

SHOP

OFFICE

2B4A

4E

PAINT SHOP

4C

PAINT SHOP

4B

PAINT SHOP

TOILET

4D

STAIR

OFFICE

5A

TOILET

5B

GIP

STORAGE

OFFICE

5C

13G

OFFICE

OFFICE

2 4

1 3

'77-XF' -

VA PROJECT NUMBER

Building Number

Drawing Number

Project Title

Date Checked Drawn

Drawing Title

Approved:

VA FORM 08-6231

A

B C

D E

21 4 5 6 7

321 4 5 6 7

A B

C E

Dwg. of

LocationLocation

Office of Construction and Facilities Management

PROJECT MANAGER: ACG Project Number

Revisions: Date

CONSULTANTS:

OCTOBER 24, 2022 ADRKTK

658-20-10520-210

CONSTRUCTION DOCUMENTS - FOR CONSTRUCTION

FULLY SPRINKLERED

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A. 34Engineers Architects

U.S. Department of Veterans Affairs

FACILITY WIDE SECURITY

CAMERAS UPGRADE

SALEM VA MEDICAL CENTER

1970 ROANOKE BLVD.

SALEM, VA 24153

CAMERA SYMBOL LEGENDCAMERA SYMBOL LEGEND

SYMBOL HEIGHT DESCRIPTION

CCTV FISH EYE

(WP-WEATHER PROOF)

TYPE

12 MP

H4F-DO1-IR

5 MP H5A

24 MP

24C-H4A-3MH

CCTV FIXED DOME

(WP-WEATHER PROOF)

6 MP H5A

360 32 MP

32C-H4A-4MH

3 MP

H4 LPC

FE

MANUFACTURER

AVIGILON

TOTAL

DEVICES

AVIGILON

AVIGILON

AVIGILON

AVIGILON

AVIGILON

AVIGILON

CCTV FIXED DOME

(WP-WEATHER PROOF)

CCTV MULTISENSOR

(WP-WEATHER PROOF)

CCTV MULTISENSOR

(WP-WEATHER PROOF)

CCTV MULTISENSOR

(WP-WEATHER PROOF)

CCTV MULTISENSOR

(WP-WEATHER PROOF)

CCTV LICENSE PLATE

(WP-WEATHER PROOF)

24 MP

24C-H4A-3MH

24 MP

24C-H4A-3MH

D6

360L

CAMERA ABBREVIATIONS

N

RP

RV

WP

PROVIDE AND INSTALL NEW CAMERA

REPLACE EXISTING CAMERA WITH NEW CAMERA

REMOVE EXISTING CAMERA

WEATHER PROOF

SPECIAL NOTE

ALL CAMERAS LOCATED ON THE EXTERIOR OF THE

BUILDING ARE SHOWN ON SHEET TS101 UNLESS

NOTED OTHERWISE.

WALL RATINGS LEGEND:

SMOKE WALLS S S S

1 HOUR FIRE WALL

S

2 HOUR FIRE WALL

3 HOUR FIRE WALL

D5

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

AVIGILON

77TK101

BUILDING 77 BASEMENT FLOOR

SECURITY PLAN

1 BUILDING 77 BASEMENT FLOOR SECURITY PLAN

1/8" = 1'-0"

00 4 8 16

NORTH

SHEET NOTES:

SHEET KEY NOTES:X

A. NO INTERIOR CAMERAS TO BE REMOVED,

REPLACED, OR ADDED. REFERENCE SHEET

TS101 FOR EXTERIOR CAMERA LOCATIONS.

B. CCTV SERVICES ARE TO REMAIN ACTIVE

OUTSIDE AREAS UNDER ACTIVE CONSTRUCTION

AT ALL TIMES. RETAIN SERVICES TO SYSTEMS

DURING DEMOLITION AND REMODEL OF THE

RESPECTIVE AREAS.

C. ALL EXISTING CONDITIONS ARE BASED ON THE

BEST AVAILABLE INFORMATION AT THE TIME OF

SURVEY AND VISUAL INSPECTION. VERIFY

EXISTING CONDITIONS.

D. NEW CCTV CABLING TO BE RUN ON J-HOOKS 2'

OC ABOVE CEILING IN CORRIDORS.

E. ALL CONDUIT SECURITY JUNCTION BOXES AND

RACEWAY PROVIDED BY EC UNO. ALL CONDUIT

SHALL BE 3/4" MINIMUM. EC TO SIZE CONDUIT

PER THE MOST CURRENT EDITION OF THE NEC.

F. WHERE LENGTH FROM CAMERA TO RACK

EQUIPMENT EXCEED 295' (90M) CONTRACTOR

SHALL USE FIBER OPTIC CABLE AS ILLUSTRATED

IN DETAIL 7/T-502.

G. COORDINATE AND CONFIRM ALL ROUTING WITH

COR PRIOR TO ROUGH-IN.

1. PROVIDE NEW 4", UL LISTED SLEEVE.

2. PROPOSED LOCATION FOR NEW PoE MID-SPAN

DEVICE, AND SHELF, MOUNTED IN EXISTING, WALL

MOUNTED DATA RACK (VERIFY LOCATION WITH

COR AND OIT REPRESENTATIVE). PROVIDE NEW,

FLOOR MOUNTED UPS CLOSE ENOUGH FOR PoE

MID-SPAN DEVICE TO PLUG INTO UPS.

COORDINATE WITH PoE MID-SPAN DEVICE

MANUFACTURER FOR POWER CORD LENGTH.

REFERENCE 2/T-602 FOR MORE INFORMATION.

3. PROVIDE POWER OUTLET FOR NEW CCTV

EQUIPMENT. INSTALL POWER OUTLET WITHIN 5

FEET OF NEW UPS LOCATION.

4. REMOVE EXISTING CAMERA FIELD DISTRIBUTION

BOX AND ENCODER. SURRENDER EQUIPMENT TO

THE POLICE.

5. ELECTRICAL ROOM ON SECOND FLOOR STACKED

OVER THIS AREA.

DocuSign Envelope ID: 3ADC3376-EFA9-4753-9EE8-D15D0B94D50D

EXISTING PANEL

- PANEL '77-XF'

SHEET NOTES:

VA PROJECT NUMBER

Building Number

Drawing Number

Project Title

Date Checked Drawn

Drawing Title

Approved:

VA FORM 08-6231

A

B C

D E

21 4 5 6 7

321 4 5 6 7

A B

C E

Dwg. of

LocationLocation

Office of Construction and Facilities Management

PROJECT MANAGER: ACG Project Number

Revisions: Date

CONSULTANTS:

OCTOBER 24, 2022 ADRKTK

658-20-10520-210

CONSTRUCTION DOCUMENTS - FOR CONSTRUCTION

FULLY SPRINKLERED

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A. 34Engineers Architects

U.S. Department of Veterans Affairs

FACILITY WIDE SECURITY

CAMERAS UPGRADE

SALEM VA MEDICAL CENTER

1970 ROANOKE BLVD.

SALEM, VA 24153

CAMERA SYMBOL LEGENDCAMERA SYMBOL LEGEND

SYMBOL HEIGHT DESCRIPTION

CCTV FISH EYE

(WP-WEATHER PROOF)

TYPE

12 MP

H4F-DO1-IR

5 MP H5A

24 MP

24C-H4A-3MH

CCTV FIXED DOME

(WP-WEATHER PROOF)

6 MP H5A

360 32 MP

32C-H4A-4MH

3 MP

H4 LPC

FE

MANUFACTURER

AVIGILON

TOTAL

DEVICES

AVIGILON

AVIGILON

AVIGILON

AVIGILON

AVIGILON

AVIGILON

CCTV FIXED DOME

(WP-WEATHER PROOF)

CCTV MULTISENSOR

(WP-WEATHER PROOF)

CCTV MULTISENSOR

(WP-WEATHER PROOF)

CCTV MULTISENSOR

(WP-WEATHER PROOF)

CCTV MULTISENSOR

(WP-WEATHER PROOF)

CCTV LICENSE PLATE

(WP-WEATHER PROOF)

24 MP

24C-H4A-3MH

24 MP

24C-H4A-3MH

D6

360L

CAMERA ABBREVIATIONS

N

RP

RV

WP

PROVIDE AND INSTALL NEW CAMERA

REPLACE EXISTING CAMERA WITH NEW CAMERA

REMOVE EXISTING CAMERA

WEATHER PROOF

SPECIAL NOTE

ALL CAMERAS LOCATED ON THE EXTERIOR OF THE

BUILDING ARE SHOWN ON SHEET TS101 UNLESS

NOTED OTHERWISE.

WALL RATINGS LEGEND:

SMOKE WALLS S S S

1 HOUR FIRE WALL

S

2 HOUR FIRE WALL

3 HOUR FIRE WALL

D5

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

AVIGILON

77TK121

BUILDING 77 SECOND FLOOR

SECURITY PLAN

1 BUILDING 77 SECOND FLOOR SECURITY PLAN

1/8" = 1'-0"

00 4 8 16

NORTH

SHEET KEY NOTES:X

A. NO INTERIOR CAMERAS TO BE REMOVED,

REPLACED, OR ADDED. REFERENCE SHEET

TS101 FOR EXTERIOR CAMERA LOCATIONS.

B. CCTV SERVICES ARE TO REMAIN ACTIVE

OUTSIDE AREAS UNDER ACTIVE CONSTRUCTION

AT ALL TIMES. RETAIN SERVICES TO SYSTEMS

DURING DEMOLITION AND REMODEL OF THE

RESPECTIVE AREAS.

C. ALL EXISTING CONDITIONS ARE BASED ON THE

BEST AVAILABLE INFORMATION AT THE TIME OF

SURVEY AND VISUAL INSPECTION. VERIFY

EXISTING CONDITIONS.

D. NEW CCTV CABLING TO BE RUN ON J-HOOKS 2'

OC ABOVE CEILING IN CORRIDORS.

E. ALL CONDUIT SECURITY JUNCTION BOXES AND

RACEWAY PROVIDED BY EC UNO. ALL CONDUIT

SHALL BE 3/4" MINIMUM. EC TO SIZE CONDUIT

PER THE MOST CURRENT EDITION OF THE NEC.

F. WHERE LENGTH FROM CAMERA TO RACK

EQUIPMENT EXCEED 295' (90M) CONTRACTOR

SHALL USE FIBER OPTIC CABLE AS ILLUSTRATED

IN DETAIL 7/T-502.

G. COORDINATE AND CONFIRM ALL ROUTING WITH

COR PRIOR TO ROUGH-IN.

1. PROVE NEW 1P, 20A CIRCUIT BREAKER FOR NEW

OUTLET IN BASEMENT IT ROOM 4A.

DocuSign Envelope ID: 3ADC3376-EFA9-4753-9EE8-D15D0B94D50D

TO

B

LD

G

TUNNEL BELOW GRADE

FIRE PROTECTION

SUPPLY PROCESSING AND

DISTRIBUTION

SPD

SCISSOR LIFT MOTOR

ROLL UP DOOR ROLL UP DOORROLL UP DOOR

DOCK LEVELLER DOCK LEVELLER

PIT BELOW 1' 2" WIDE AND 1' 6" DEEP

SIM TO DET. 3/UT-A4

REMOVABLE GAL. STEEL

GRATING W/BEARING BAR

SCISSOR LIFT UP DOWN

PUSH BUTTON CONTROL

4' 0" ABOVE FIN. FLOOR

TO BLDG 2A

INFORMATION

DESK

ICE

MACH

FP

TO BLDG 5

WASHERAREA

HOLDING

STEAMER

STAINLESS STEEL

STERID UNIT

CONVEYOR BELT

FEC

CLEAN

SUPPLY

BB-140

CLEAN

LINEN

BG-115H

TELE

BF-110A

ELE/

MECH

BE-103A

CORR.

CB-52

TOILET

BG-115A

MEDICINE

RM

BG-131A

TELE.

BB-162

TELEBB-

140A

FP

BA-103A

TOILET

BB-121

EQUIP.

STOR.

CORR.CB-29D

PRESCR REC

BF-104

PRESSURE

RM

TOILET

BF-113

HAC HOUSE

KEEPING

BF-112

TELE

BF-114

ELECTRICAL

BF-115

FP

TLT/ LKR

BE-116

SHOWER

BE-116A

CORR.

CB-35A

MECH RM

BE-114

MED

GAS

BE-109

MED

GAS

BE-108

FLAM

STOR

BE-107

HAC

BC-100

STORAGE

BC-103ASTORAGE

EQUIPMENT/TOILET

BC-105

WHCH TOILET

BC-104ARM AND LEG WHRLP

BC-107

EQUIP

WASHBD-106

F. TLT

BD-102A

F. SHWR/

LKR

BD-102

TLT

BC-110

EQUIP / STRET STORAGE

WHCH TOILET

BC-118

WHCH

TLT MALE

BC-117B

TELE.

BC-114

WOMENS

TOILET

BC-122B

TLT

BC-123C MENS

TLT

BC-122C

EQUIP.

STORAGEBC-123A

HAC

BC-127C

SOIL

UTILITYBC-127

M. TLT

BD-115A

FEMALE

TOILET

BD-116A

CART

DRY

BD-117A

HAC

BD-112

EQUIP GAS

CYLINDER STORAGE

BD-110

WOMENS

LOCKERBD-116

PASSAGE WAY

CB-33

TOILET

BD-107A

STERILE PREPARATION RM

BD-103A

SECY /

WAITING

BB-155

MULTI-

PURPOSE

MULTI-

PURPOSE

NURSE STATION

CB-48

PT

DRESSINGBC-103

EQUIPMENT

STORAGE

BC-107A

CLEAN

UTILITY

BD-101

RECEPT / PHARM

BF-105

CORRIDOR

CB-29B

CB-29C

PRIMARY CARE

NURSE

BG-124

WAITING

BC-122

WAITING RM

CB-12

D-2

EQUIPMENT

STORAGE

BC-102

LINEN

BC-129

OXYGEN

STORAGE

BC-138

IV ADMIXTURE

CORR.

CB-24

OCCUPATIONAL THERAPY

BC-116

CASH CART

BB-146

TUMOR

REG.

BB-147

EXAM /

TREATMENT

BB-150

CORR.

CB-53

CORR.

CB-29A

BC-125D

CORR.

CB-42

CORR.

CB-41

WAITING RM

CB-8

RECEPTION

CB-8A

WAITING RM

CB-9WAITING

CB-10

CONSULT RM

BF-101

CONSULT RM

BF-102

CONSULT RM

BF-103

TRAINING

RM

SECY

BB-154

POD

EXAM

BG-109

EXAM

BG-100

POD

EXAM

BG-105

POD

EXAM

BG-107

AUTOPSY RM

BE-112

MORT REFRIG

MORGUE

BE-113

CORR.

CB-38

EXAM

BC-126J

EXAM

BC-126I

EXAM

BC-126H

EXAM

BC-126G

EXAM

BC-126F

EXAM /

TREAT

BC-126E

CORRIDOR

CB-19

OFFICE

BB-141

EXAM

BB-133

BA-102D

SVC BAY

BF-118

CONCOURSE

CB-6

WAITING RM

CB-7

WAITING RM

CB-14

CORRIDOR

CB-15

CORR.

CB-16

EXAM /

TRTMNT

BB-107

CORRIDOR

CB-17

NURSE

STATION

CB-18

TOILET MALE

BB-100

WOMENS

TOILET

BB-101

EXAM /

TREATMENT

BB-112

OFFICE

BB-115EXAM

BB-116

IT

SPECIALIST

OFFICEBB-114

OFFICE

BB-113

ELEC.

BB-102

SVC BAY

BB-165

DIABETIC

CLASS RM

BB-104

SVC BAY

BB-137 STAIR

RECEPTION

CB-13A

CORR.

CB-22

STAIR

NO-5

CORR.

CB-28

LOBBY

CB-5

OFFICE

BA-105

OFFICE

BA-102C

AGENT

CASHIER

BA-104

OFFICE

BA-103

WOMENS

TOILETBA-100

MENS

TOILETBA-101

AGENT

CASHIER

BA-104B OFFIC OFFICE OFFICE

IDRM OFFICE

BA-106D

CAFE

BA-102

BA-102A

BA-102B

OFFICE

BA-101B

STORAGE

BE-103

DECONTAM RM

BD-103

AITO

CART

WASH

BD-104

CLEAN SUPPLY

BD-117

CORR.

CB-30

CLEAN SUPPLY

BD-117B

SVC BAY

BD-118

GENERAL

STORAGE

PAP AND EMP

CLOTHING

BE-100A

ELECTRICAL

BE-101

ELECTRICAL

BE-102

EMS

BE-117

HAC

BE-115

CORR.

CB-37

GROSS

SPEC

STORE

BE-118

CORR.

CB-45

TELE.

BG-138

CONCOURSE

CB-15

EXAM

BB-153

OFFICE

BB-122

EXAM /

TREATMENT

BB-123

EXAM /

TREATMENT

BB-125

CORRIDOR

CB-20

OFFICE

SOCIAL

WORKERBB-129

EXAM /

TREATMENT

BB-145

CORR.

CB-21

PHARMACY

BF-110

SVC BAY

BF-116

VAULT STORAGE /

DISPENSE

BF-109

OFFICE

CHIEF

RMS

BB-157

CLINICAL

DIETITIAN OFFICE

OFFICE

ASST CHIEF

BB-152

CHIEF

BB-149

MEN TOILET

BB-155

PHYS THERAPY

BC-101

TREATMENT

BC-101A

WORK AREA / OFFICE

BC-109

OFFICE /

WORK AREA

BC-106

STAIR

NO-1

PHARMACY STORAGE

BE-104

OFFICE

BE-105

BE-106

STAFF

TOILET

BE-111

OFFICE

BE-110

TELE

BE-100

ELEC

BD-100

CLEAN SUPPLY

BD-117C

OPEN OUTSIDE

AREA WAY

TRANSFORMER

RM 4

BG-121

SWITCH

BOARD

BG-121A

TELE /

SIGNAL

BG-120

SVC BAY

BG-119

CORRIDOR

CB-44CRAWL SPACESTAIR

NO-3

SWITCH

BOARD RM

BF-117ATRANSFORMER RM

BF-117

LOBBY

CB-39

VESTIBULE

CB-40

STAIR

NO-2

ELEVATOR

ELEVATOR

S-4

CHIEF

OFFICE

BF-108

SUPER

PHARM

BF-106C

DRUG INFO

SVC

BF-106

CLERICAL OFFICE /

WORK AREA

BF-106B

CHIEF

CONFERENCE

RMBF-107

SECY / WAITING

BF-106A

LOBBY

CB-11

ELEVATOR

P-3

LOUNGE

BG-117

EXAM/

TREATMENT

BG-123

OFFICE

BG-125

EXAM

BG-116

EXAM/

TREATMENT

BG-127

EXAM/

TREATMENT

BG-114

OFFICEBG-112

EXAM/OFFICE

BG-128

DIRTY

UTILITY

BG-129

GENERAL

STORAGE

BG-111

BREAK RM

BF-110D EXAM

RM

BG-115D

EXAM

RM

BG-115C

EXAM

RM

BG-115B

EXAM

RM

BG-115E

EXAM

RM

BG-115F OFFICE

BG-115G

OFFICE

BG 113

ELECTRICAL

BG-103

OFFICE

BG-104

OFFICE

BG-110

CORR.

CB-43

HAC

BG-

EXAM

RM

BG-126A

CORRIDOR

BG-126

OFFICE/EXAM

RMBG-126D

CORR.

CB-46

EXAM

RM

BG 126B

EXAM/OXYGEN

STORAGE

BG-126C

OFFICE

BG-131

OFFICE

BG-132

ELEC.

BG-139

OFFICE

BG-137

EXAM

BG-135

EXAM

BG-134

CORRIDOR

CB-47

EXAM /

TREATMENT

BG-108

EXAM /

TREATMENT

BG-136

EXAM

BG-133

EXAM

BG-106

CORR.

CB-49

OFFICE

BG-101

OFFICE

BG-102

CORRIDOR

CB-50

CORR.

CB-51

OFFICE

BF-110C

IV ADMIXTURE STORAGE AREA

BF-110B

CLEAN LINEN STORE

BC-131

KEMO RM

BF-111A

IV ADMIXTURE

BF-111

ELEVATOR

S-1

ELEVATOR

S-2

ELEVATOR

S-3

S ELEVATOR LOBBY

CB-36

CORR.

CB-32

HALLWAY

CB-34

ELEVATOR / MACH

BD-109

MALE SHOWER

BD-107

HACBD-105

OFFICE

BD-111

STAIR

NO-8

CORRIDOR

CB-31

ELECTRICAL

BD-122A

TRANSFORMER

RM 2

BD-122

SVC BAY

MECH

STORAGE

BD-123A

SVC BAY

BD-123

ENG CONTR CENTER

BD-124

STAIR

NO-7

CORR.

CB-35

CORR.

CB-27

CHIEF

BD-114C

CORRECT KINESLO

THERAPY

BC-113

EQUIPMENT

STORAGE

BC-111

BC-112

THERAPY

WAITING RM

BC-115

OFFICE

BC-117A

KITCHEN

BC-117

BC-121

SPLINTING

BC-120

EQUIP

STORE

BC-119

M.

LKRS

BD-115

CLER

BD-114

ASST CHIEF

BD-114B

OFFICE

BD-108

LOUNGE

BD-113

CL-2

COMPUTER

BD-114A

EXAM /

TREATMENT

BB-109

EXAM /

TRTMNT

BB-105

EXAM /

TREATMENT

BB-136

EXAM /

TREATMENT

BB-106

OFFICE

BB-108

EXAM

BB-134

CLEAN

UTILITY

BB-117

DIRTY

UTILITY

BB-128

EXAM /

TREATMENT

BB-119

EXAM /

TREATMENT

BB-126

EXAM /

TREATMENT

BB-110

EXAM /

TREATMENT

BB-132

EXAM /

TREATMENT

BB-111

EXAM /

TREATMENT

BB-130

EXAM /

TREATMENT

BB-120

EXAM /

TREATMENT

BB-124

EXAM /

TREATMENT

BB-151

EXAM /

TREATMENT

BB-127

EXAM /

TRTMNT

BB-148

EXAM /

TREATMENT

BB-143

EXAM /

TREATMENT

BB-131

EXAM

BB-135

EXAM /

TREATMENT

BB-139

OFFICE

CLINICAL

DIETITIAN

BB-163

ELEC.

BB-161

OFFICE

SPEECH

PATHOLOGYBB-160

OFFICE RMS

COORD.

BB-159

OFFICE

PATIENT

HEAD

BB-158

CORR.

CB-23

HOUSE

KEEPING

COPY

RM

BB-142

LOUNGE

BB-138

OFFICE

SPEECH

PATHOLOGY

BB-164

CLEAN

LINEN

BC-127B

CLN

SUPP

BC-127A

STR

NO-4

MEDS

BC-123B

EDUCATION

OFFICE

BC-123

LOUNGE

BC-124

NURSE

STATION

BC-126

NURSE

STATION

BC-125

EXAM

BC-125K

EXAM

BC-125J

EXAM

BC-125IEXAM

BC-125E

EXAM

RM

BC-125F

EXAM

BC-125G

EXAM/

OFFICEBC-125H

EXAM

BC-125C

EXAM

BC-125B

EXAM

BC-125A

OFFICE

BC-126D

EXAM

BC-126C

EXAM

BC-126B

EXAM

BC-126A

RECEPTION

BC-122A

ELEVATOR

P-1

ELEVATOR

P-2

WAITING RM

CB-13

OFFICE

MULTI-

PURPOSE

BB-103

SHAFT

ELEVATOR

CORR.

SHAFT

SHAFT

TOILET

TOILET

CORRIDOR

ELEVATOR

CORR.

ELECTRICAL

BC-108

A&MM WAREHOUSE

A&MM WAREHOUSE

MAIL ROOM

A&MM WAREHOUSE

A&MM WAREHOUSE

A&MM WAREHOUSE

SPD SPD

SPD

SPD

MECH

BE-103A

SPD

SCOPE

PROCESSING

BREAKDOWN ROOM

BE-103B

A&MM WAREHOUSE

BD-103C

OFFICE

BD-117C

A&MM WAREHOUSE

SPD

SCOPE

PROCESSING

BD-103B

CB-29

BB-118

BB-144

BB-156

EXIT

EXIT

EXIT

EXIT

EXIT

OFFICE

BE-105A

GENERAL

STORAGE

TOILET TOILET

LOCKERS

OFFICE

OFFICE

TEMP

STORAGE

FOR

RETURNED

MEDS.

IV ADMIXTURE

LAB

EXAM /

TREATMENT

EXAM /

TREATMENT

EXAM

BC-116A

BC-116B

BA-106E

BA-106C

CB-

45C

OFF.

CB-

45B

OFF.

CB-

45A

OFF.

OFFICE

BA-106BBA-106A

EXIT

CORRIDOR

OFFICE

OFFICE

BF-110D

BF-110E

A&MM WAREHOUSE

MAIL ROOM

RV

RV

RV

FE

N #83

'BLD 143' -

BF-138

'BLD 143' -

BG-138

RP

#85

N #84

'BLD 143' -

BG-138

N

#87'BLD 143' -

BC-114

N #90

'BLD 143' -

BC-114

FE

N

#88 'BLD 143' -

BE-100

N #89

'BLD 143'

- BE-100

RP

#86

'BLD 143'

- BG-138

S S S S S S

S

S S S S S

S

S S S S S S S

S S

S S

S S

S S

S S

S S

S S

S S

SSSSS

S

S

SSSSSS

S

SSSSS

S

S

S S S S

S

S S

S S

S

S S S S S

S

S S S S S

S S

S S

S

S S

S S S S S S S

S S

S S

S S

S S

S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S

S S S S S

S

EXISTING PANEL -

PANEL - 'BEELD'

S S

S S

S S

S S

SSSSSSS

TELE

BG-138

'143-BEELD'

- 12

TELE

BC-114

'143-BEELD'

- 14

TELE

BE-100

'143-BEELD'

- 16

VA PROJECT NUMBER

Building Number

Drawing Number

Project Title

Date Checked Drawn

Drawing Title

Approved:

VA FORM 08-6231

A

B C

D E

21 4 5 6 7

321 4 5 6 7

A B

C E

Dwg. of

LocationLocation

Office of Construction and Facilities Management

PROJECT MANAGER: ACG Project Number

Revisions: Date

CONSULTANTS:

OCTOBER 24, 2022 ADRKTK

658-20-10520-210

CONSTRUCTION DOCUMENTS - FOR CONSTRUCTION

FULLY SPRINKLERED

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A. 34Engineers Architects

U.S. Department of Veterans Affairs

FACILITY WIDE SECURITY

CAMERAS UPGRADE

SALEM VA MEDICAL CENTER

1970 ROANOKE BLVD.

SALEM, VA 24153

CAMERA SYMBOL LEGENDCAMERA SYMBOL LEGEND

SYMBOL HEIGHT DESCRIPTION

CCTV FISH EYE

(WP-WEATHER PROOF)

TYPE

12 MP

H4F-DO1-IR

5 MP H5A

24 MP

24C-H4A-3MH

CCTV FIXED DOME

(WP-WEATHER PROOF)

6 MP H5A

360 32 MP

32C-H4A-4MH

3 MP

H4 LPC

FE

MANUFACTURER

AVIGILON

TOTAL

DEVICES

AVIGILON

AVIGILON

AVIGILON

AVIGILON

AVIGILON

AVIGILON

CCTV FIXED DOME

(WP-WEATHER PROOF)

CCTV MULTISENSOR

(WP-WEATHER PROOF)

CCTV MULTISENSOR

(WP-WEATHER PROOF)

CCTV MULTISENSOR

(WP-WEATHER PROOF)

CCTV MULTISENSOR

(WP-WEATHER PROOF)

CCTV LICENSE PLATE

(WP-WEATHER PROOF)

24 MP

24C-H4A-3MH

24 MP

24C-H4A-3MH

D6

360L

CAMERA ABBREVIATIONS

N

RP

RV

WP

PROVIDE AND INSTALL NEW CAMERA

REPLACE EXISTING CAMERA WITH NEW CAMERA

REMOVE EXISTING CAMERA

WEATHER PROOF

SPECIAL NOTE

ALL CAMERAS LOCATED ON THE EXTERIOR OF THE

BUILDING ARE SHOWN ON SHEET TS101 UNLESS

NOTED OTHERWISE.

WALL RATINGS LEGEND:

SMOKE WALLS S S S

1 HOUR FIRE WALL

S

2 HOUR FIRE WALL

3 HOUR FIRE WALL

D5

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

AVIGILON

143TK101

2 BUILDING 143 BASEMENT FLOOR SECURITY PLAN

1/16" = 1'-0"

0 8 16 320

NORTH

SHEET NOTES:

1. REMOVE EXISTING CAMERA AND CABLING BACK

TO SOURCE.

2. INSTALL NEW CAMERA. PROVIDE AND INSTALL

NEW 4 PR UTP CABLING TO NEW PoE MID-SPAN

DEVICE IN IT ROOM BG-138. REPAIR/REPLACE

SURFACES AFFECTED BY CAMERA EQUIPMENT

INSTALLATION TO MATCH SIMILAR/EXISTING

CONDITIONS.

3. INSTALL NEW CAMERA. PROVIDE AND INSTALL

NEW 4 PR UTP CABLING TO NEW PoE MID-SPAN

DEVICE IN IT ROOM BC-114. REPAIR/REPLACE

SURFACES AFFECTED BY CAMERA EQUIPMENT

INSTALLATION TO MATCH SIMILAR/EXISTING

CONDITIONS.

4. INSTALL NEW CAMERA. PROVIDE AND INSTALL

NEW 4 PR UTP CABLING TO NEW PoE MID-SPAN

DEVICE IN IT ROOM BE-100. REPAIR/REPLACE

SURFACES AFFECTED BY CAMERA EQUIPMENT

INSTALLATION TO MATCH SIMILAR/EXISTING

CONDITIONS.

5. REMOVE EXISTING CAMERA. REMOVE

ASSOCIATED EXISTING LOW-VOLTAGE WIRING

BACK TO SOURCE. REPAIR/REPLACE SURFACES

AFFECTED BY REMOVAL OF CAMERA EQUIPMENT

TO MATCH SIMILAR EXISTING CONDITIONS.

6. PROPOSED LOCATION FOR NEW PoE MID-SPAN

DEVICE MOUNTED IN EXISTING, WALL MOUNTED

DATA RACK (COORDINATE LOCATION WITH COR

AND OIT REPARESENTATIVE). PROVIDE NEW,

FLOOR MOUNTED UPS CLOSE ENOUGH FOR PoE

MID-SPAN DEVICE TO PLUG INTO UPS.

COORDINATE WITH PoE MID-SPAN DEVICE

MANUFACTURER FOR POWER CORD LENGTH.

REFERENCE 2/T-602 FOR MORE INFORMATION.

7. PROVIDE POWER OUTLET FOR NEW CCTV

EQUIPMENT. INSTALL POWER OUTLET WITHIN 5

FEET OF NEW UPS LOCATION. SIZE CONDUIT AND

CONDUCTORS PER THE LATEST EDITION OF THE

NEC.

8. EXISTING WALL MOUNTED SWITCHES AND PATCH

PANELS.

9. PROPOSED LOCATION FOR NEW PoE MID-SPAN

DEVICE AND NEW WALL MOUNTED SHELF

(COORDINATE LOCATION WITH COR AND OIT

REPRESENTATIVE). PROVIDE NEW, FLOOR

MOUNTED UPS CLOSE ENOUGH FOR PoE

MID-SPAN DEVICE TO PLUG INTO UPS.

COORDINATE WITH PoE MID-SPAN DEVICE

MANUFACTURER FOR POWER CORD LENGTH.

REFERENCE 2/T-601 FOR MORE INFORMATION.

10. PROVIDE 3 NEW 1P, 20A CIRCUIT BREAKER IN

EXISTING PANEL FOR NEW RECEPTACLE IN IT

ROOMS BG-138, BC-114, AND BE-100.

11. EXISTING VSS MONITOR AND PC TO REMAIN.

REWORK SO EXISTING MONITORING CAPABILITIES

AT THIS LOCATION ARE RE-ESTABLISHED AFTER

WORK IS COMPLETE. COORDINATE ANY

DOWNTIME WITH PHARMACY STAFF.

12. REMOVE EXISTING CAMERA FIELD DISTRIBUTION

BOX AND ENCODER. SURRENDER EQUIPMENT TO

THE POLICE.

13. PROVIDE NEW 4", UL LISTED SLEEVE.

0 2 4 8

NORTH

1 1/4" = 1'-0"

TELECOM ROOM ENLARGEMENTS

143TK101

A. HOME RUN FROM CAMERAS INDICATES THE

TELECOMMUNICATIONS ROOM TO BE USED FOR

NEW CABLING TERMINATIONS ON EXISTING

PATCH PANELS.

B. CCTV SERVICES ARE TO REMAIN ACTIVE

OUTSIDE AREAS UNDER ACTIVE CONSTRUCTION

AT ALL TIMES. FIELD VERIFY CIRCUITS SHOWN

AND RETAIN SERVICES TO ALL DEVICES AND/OR

SYSTEMS DURING DEMOLITION AND REMODEL

OF THE RESPECTIVE AREAS.

C. ALL EXISTING CONDITIONS AND DEVICES ARE

BASED ON THE BEST AVAILABLE INFORMATION

AT THE TIME OF SURVEY AND VISUAL

INSPECTION. VERIFY EXISTING CONDITIONS IN

FIELD.

D. REMOVE ALL UNUSED CONDUIT AND CABLING.

E. INSTALL CONDUCTORS AND CONDUITS

CONCEALED IN NEW WALLS AND PROVIDE A NEW

FACEPLATE.

F. ALL NEW RECEPTACLES SHALL BE LABELED

WITH THEIR SOURCE PANEL AND CIRCUIT

NUMBER.

G. NEW CCTV CABLING TO BE RUN ON J-HOOKS 2'

OC ABOVE CEILING IN CORRIDORS.

H. ALL CONDUIT SECURITY JUNCTION BOXES AND

RACEWAY PROVIDED BY ELECTRICAL

CONTRACTOR UNO. ALL CONDUIT SHALL BE 3/4"

MINIMUM. ELECTRICAL CONTRACTOR TO SIZE

CONDUIT PER THE MOST CURRENT EDITION OF

THE NEC.

I. ALL DEMOLISHED CAMERAS AND ASSOCIATED

EQUIPMENT SHALL BE TURNED OVER TO THE

POLICE DEPARTMENT. COORDINATE WITH COR.

J. COORDINATE EXACT LOCATION OF ALL CAMERAS

DESIGNATED TO BE REMOVED PRIOR TO ANY

WORK BEING DONE.

K. CONTRACTOR TO REPLACE DAMAGED CEILING

TILE AND GRID ASSOCIATED WITH WORK AT NO

ADDITIONAL COST TO THE GOVERNMENT.

L. COORDINATE AND CONFIRM ALL CABLE ROUTING

WITH COR PRIOR TO ROUGH-IN.

BUILDING 143 BASEMENT FLOOR

SECURITY PLAN AND TELECOM ROOM

ENLARGEMENTS

SHEET KEY NOTES:X

143TK101

143TK101

DocuSign Envelope ID: 3ADC3376-EFA9-4753-9EE8-D15D0B94D50D

UNISEX

TOILET

VEST

101A

CORR

ELEC

ROOM

PAT.

ROOM

TOILET

166A

TOILET

167A

TOILET

165A

PAT.

ROOM

PAT.

ROOM

TOILET

164A

TOILET

163A

PAT.

ROOM

PAT.

ROOM

TOILET

162A

TOILET

161A

PAT.

ROOM

PAT.

ROOM

TOILET

160A

PAT.

ROOM

TOILET

159A

GROUP

GROUP

TOILET

157AEMER

EXIT

DINING

DAYROOM

PAT.

ROOM

154TOILET

154A

PAT.

ROOM

TOILET

153A

PAT.

ROOM

TOILET

152A

TOILET

151A

PAT.

ROOM

PAT.

ROOM

TOILET

139A

ELEC

LAUNDRY

DAYROOM/DINING

MEDS

WORK

PAT.

ROOM

TOILET

138A

TOILET

137A

PAT.

ROOM

TOILET

136A

PAT.

ROOM

136EXAM

TOILET

135A

DAYROOM/DINING

STOR

TOILET

131A

GROUP

TOILET

130A

PAT.

ROOM

PAT.

ROOM

TOILET

129A

PAT.

ROOM

TOILET

128A

TOILET

127A

PAT.

ROOM

PAT.

ROOM

TOILET

126A

CORR

PAT.

ROOM

TOILET

124A

TOILET

123A

PAT.

ROOM

PAT.

ROOM

TOILET

122A TOILET

121A

PAT.

ROOM

EXAM

TOILET

120A

LAUNDRY

DATA/

ELEC

117 ELEC

117A

STAFF

TOILET

WATER SERVICE

STAFF

TOILET

STAFF

SECL

TOILET

SECL

NURSE

WORK

CORR

CORR

CORR

NOURISH/

RE-THERM

EQUIPMENT

STORAGE

LINEN

QUIET

EXAM

TDO

PROCS

VISITOR

ROOM

CORR

WAITING

NURSE

INTERVIEW

DINING

DAYROOM

TEAM

ROOM

CORR

CORR

CORR

CORRIDOR

WOMEN'S UNIT

GENERAL UNIT

GERO UNIT

ACUTE UNIT

WORK

156A

NURSE

WORK

NURSE

WORK

D6

RP

#109

WP

D6

RP

#91

1 2

1 2 1 2

D6 N #92

D6

RP

#93

N #94

N #103

N #104

D6 N

#102

N

#95

D6

RP

#96

N #101

N #105

D6

RP

#106

WP

D6

RP

#107

D6

RP

#108

N #100

FE

N #99

N #110

D6

RP

#97

N #111

N #98

N #112

D6

RP

#113

WP

N #114

D6

RP

#115

N #116

N #118

N #119

RP

#117

WP

RV

'BLD 170'

-117

'BLD 170'

-117

'BLD 170'

-117

'BLD 170'

-117

'BLD 170'

-117

'BLD 170'

-117 'BLD 170'

-117

'BLD 170'

-117

'BLD 170'

-117

'BLD 170'

-117

'BLD 170'

-117

'BLD 170'

-117

'BLD 170'

-117

'BLD 170'

-117

'BLD 170'

-117

'BLD 170'

-117

'BLD 170'

-117

'BLD 170'

-117

'BLD 170'

-117

'BLD 170'

-117

'BLD 170'

-117

'BLD 170'

-117

'BLD 170'

-117

'BLD 170'

-117

'BLD 170'

-117

'BLD 170'

-117

'BLD 170'

-117

'BLD 170'

-117

'BLD 170'

-117

S S

S S

S S

S S

S S

S

SSS

S

S S

S S

S S

S S

S S

S S S S S S S

S S

S S

S

SSSSSSS

SS

S

S

S S S

S

S S S S S S

S

SSSSS

S

S S S S S S S

S S

S S

S S

S S

S

S S S

S S S S S S S S

S S

S S

S S

S S

S

S S S S S S S S S S S S S S S

S

S S S

S S

S S S S S S S S S S S S S S S

S S

S

S S

SSSS

SS

S

SSSSSS

S

S S

S S

S S

S S

S S S S S S S S S S

S

S

S S

SSSS

S S

S S S

S S

SS

S

S

SSSSSSSSS

S

S

S S

S S

SSSSS

S

S S S S S S

S S

S S

S S

S S S

SS

S

S S

S S

S S

S S

S S

S S

S S

SS

S S S

S S

S S

S S

5 5

EXISTING

PANEL -

PANEL 'EQ2'

'EC2' - 34

EXISTING

PANEL -

PANEL 'EC2'

EXISTING

PANEL -

PANEL 'LS2'12

'EC2' - 36

VA PROJECT NUMBER

Building Number

Drawing Number

Project Title

Date Checked Drawn

Drawing Title

Approved:

VA FORM 08-6231

A

B C

D E

21 4 5 6 7

321 4 5 6 7

A B

C E

Dwg. of

LocationLocation

Office of Construction and Facilities Management

PROJECT MANAGER: ACG Project Number

Revisions: Date

CONSULTANTS:

OCTOBER 24, 2022 ADRKTK

658-20-10520-210

CONSTRUCTION DOCUMENTS - FOR CONSTRUCTION

FULLY SPRINKLERED

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A. 34Engineers Architects

U.S. Department of Veterans Affairs

FACILITY WIDE SECURITY

CAMERAS UPGRADE

SALEM VA MEDICAL CENTER

1970 ROANOKE BLVD.

SALEM, VA 24153

CAMERA SYMBOL LEGENDCAMERA SYMBOL LEGEND

SYMBOL HEIGHT DESCRIPTION

CCTV FISH EYE

(WP-WEATHER PROOF)

TYPE

12 MP

H4F-DO1-IR

5 MP H5A

24 MP

24C-H4A-3MH

CCTV FIXED DOME

(WP-WEATHER PROOF)

6 MP H5A

360 32 MP

32C-H4A-4MH

3 MP

H4 LPC

FE

MANUFACTURER

AVIGILON

TOTAL

DEVICES

AVIGILON

AVIGILON

AVIGILON

AVIGILON

AVIGILON

AVIGILON

CCTV FIXED DOME

(WP-WEATHER PROOF)

CCTV MULTISENSOR

(WP-WEATHER PROOF)

CCTV MULTISENSOR

(WP-WEATHER PROOF)

CCTV MULTISENSOR

(WP-WEATHER PROOF)

CCTV MULTISENSOR

(WP-WEATHER PROOF)

CCTV LICENSE PLATE

(WP-WEATHER PROOF)

24 MP

24C-H4A-3MH

24 MP

24C-H4A-3MH

D6

360L

CAMERA ABBREVIATIONS

N

RP

RV

WP

PROVIDE AND INSTALL NEW CAMERA

REPLACE EXISTING CAMERA WITH NEW CAMERA

REMOVE EXISTING CAMERA

WEATHER PROOF

SPECIAL NOTE

ALL CAMERAS LOCATED ON THE EXTERIOR OF THE

BUILDING ARE SHOWN ON SHEET TS101 UNLESS

NOTED OTHERWISE.

WALL RATINGS LEGEND:

SMOKE WALLS S S S

1 HOUR FIRE WALL

S

2 HOUR FIRE WALL

3 HOUR FIRE WALL

D5

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

CEILING

MOUNTED

AVIGILON

170TK101

BUILDING 170 BASEMENT FLOOR

SECURITY PLAN

1 BUILDING 170 BASEMENT FLOOR SECURITY PLAN

1/8" = 1'-0"

00 4 8 16

NORTH

1. REMOVE EXISTING CAMERA AND CABLING BACK

TO SOURCE.

2. INSTALL NEW CAMERA. PROVIDE AND INSTALL

NEW 4 PR UTP CABLING TO NEW PoE MID-SPAN

DEVICE IN IT ROOM 117. REPAIR/REPLACE

SURFACES AFFECTED BY CAMERA EQUIPMENT

INSTALLATION TO MATCH SIMILAR/EXISTING

CONDITIONS.

3. REMOVE EXISTING CAMERA. REMOVE

ASSOCIATED EXISTING LOW-VOLTAGE WIRING

BACK TO SOURCE. REPAIR/REPLACE SURFACES

AFFECTED BY REMOVAL OF CAMERA EQUIPMENT

TO MATCH SIMILAR EXISTING CONDITIONS.

4. PROPOSED LOCATION FOR NEW PoE MID-SPAN

DEVICE MOUNTED IN EXISTING DATA RACK

(COORDINATE LOCATION WITH COR AND OIT

REPRESENTATIVE). PROVIDE NEW, FLOOR

MOUNTED UPS CLOSE ENOUGH FOR PoE

MID-SPAN DEVICE TO PLUG INTO UPS.

COORDINATE WITH PoE MID-SPAN DEVICE

MANUFACTURER FOR POWER CORD LENGTH.

REFERENCE 2/T-602 FOR MORE INFORMATION.

5. PROVIDE NEW 4", UL LISTED SLEEVE ASSEMBLY.

6. PROVIDE POWER OUTLET (NEMA L5-30R) FOR NEW

CCTV EQUIPMENT. INSTALL POWER OUTLET

WITHIN 5 FEET OF NEW UPS LOCATION.

7. REMOVE EXISTING CAMERA FIELD DISTRIBUTION

BOX AND ENCODER. SURRENDER EQUIPMENT TO

THE POLICE.

8. MOUNT CAMERA ON COLUMN, AS HIGH AS

POSSIBLE.

9. MOUNT NEW CAMERA IN HIGH IMPACT SECURITY

CASING.

10. MOUNT NEW CAMERA IN EXISTING HIGH IMPACT

SECURITY CASING.

11. PROVIDE NEW POWER OUTLET FOR VSS MONITOR

(VIEWING ONLY). COORDINATE EXACT LOCATION

WITH COR PRIOR TO ROUGH-IN.

12. REPLACE EXISTING, SPARE, 1P, 20A CIRCUIT

BREAKER WITH NEW 1P, 30A CIRCUIT BREAKER.

13. PROPOSED LOCATION FOR NEW PCs TO SERVE

MONITORS AT NURSE WORK STATIONS.

COORDINATE EXACT LOCATION WITH COR AND OIT

REPRESENTATIVE PRIOR TO ROUGH-IN. PROVIDE

NEW TELECOMMUNICATIONS OUTLET TO SERVE

TWO PCs.

14. PROVIDE NEW POWER OUTLETS FOR CCTV PCs.

COORDINATE POWER OUTLET LOCATION WITH

COR AND OIT REPRESENTATIVE PRIOR TO

ROUGH-IN.

SHEET NOTES:

A. HOME RUN FROM CAMERAS INDICATES THE

TELECOMMUNICATIONS ROOM TO BE USED FOR

NEW CABLING TERMINATIONS ON EXISTING

PATCH PANELS.

B. CCTV SERVICES ARE TO REMAIN ACTIVE

OUTSIDE AREAS UNDER ACTIVE CONSTRUCTION

AT ALL TIMES. FIELD VERIFY CIRCUITS SHOWN

AND RETAIN SERVICES TO ALL DEVICES AND/OR

SYSTEMS DURING DEMOLITION AND REMODEL

OF THE RESPECTIVE AREAS.

C. ALL EXISTING CONDITIONS AND DEVICES ARE

BASED ON THE BEST AVAILABLE INFORMATION

AT THE TIME OF SURVEY AND VISUAL

INSPECTION. VERIFY EXISTING CONDITIONS IN

FIELD.

D. REMOVE ALL UNUSED CONDUIT AND CABLING.

E. INSTALL CONDUCTORS AND CONDUITS

CONCEALED IN NEW WALLS AND PROVIDE A NEW

FACEPLATE.

F. ALL NEW RECEPTACLES SHALL BE LABELED

WITH THEIR SOURCE PANEL AND CIRCUIT

NUMBER.

G. NEW CCTV CABLING TO BE RUN ON J-HOOKS 2'

OC ABOVE CEILING IN CORRIDORS.

H. ALL CONDUIT SECURITY JUNCTION BOXES AND

RACEWAY PROVIDED BY ELECTRICAL

CONTRACTOR UNO. ALL CONDUIT SHALL BE 3/4"

MINIMUM. ELECTRICAL CONTRACTOR TO SIZE

CONDUIT PER THE MOST CURRENT EDITION OF

THE NEC.

I. ALL DEMOLISHED CAMERAS AND ASSOCIATED

EQUIPMENT SHALL BE TURNED OVER TO THE

POLICE DEPARTMENT. COORDINATE WITH COR.

J. COORDINATE EXACT LOCATION OF ALL CAMERAS

DESIGNATED TO BE REMOVED PRIOR TO ANY

WORK BEING DONE.

K. CONTRACTOR TO REPLACE DAMAGED CEILING

TILE AND GRID ASSOCIATED WITH WORK AT NO

ADDITIONAL COST TO THE GOVERNMENT.

L. COORDINATE AND CONFIRM ALL CABLE ROUTING

WITH COR PRIOR TO ROUGH-IN.

SHEET KEY NOTES:X

DocuSign Envelope ID: 3ADC3376-EFA9-4753-9EE8-D15D0B94D50D

1. WALL ASSEMBLY - THE 1, 2, 3 OR 4 HR FIRE-RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES:

A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS (MAX 2 HR FIRE RATED ASSEMBLIES) OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER SPACED 16 IN. (406 MM) OC WITH NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN 3-5/8 IN. (92 MM)

WIDE BY 1-3/8 IN. (35 MM) DEEP CHANNELS SPACED MAX 24 IN. (610 MM) OC.

B. GYPSUM BOARD* - NOM 1/2 OR 5/8 IN. (13 OR 16 MM) THICK, 4 FT. (122 CM) WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. MAX DIAM OF

OPENING IS 26 IN. (660 MM).

2. THROUGH PENETRANT - ONE METALLIC PIPE, CONDUIT OR TUBING INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN PIPE, CONDUIT OR TUBING AND PERIPHERY OF OPENING SHALL BE MIN OF 0 IN. (0 MM) (POINT CONTACT) TO MAX 2 IN. (51 MM). PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED:

A. STEEL PIPE - NOM 24 IN. (610 MM) DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE.

B. IRON PIPE - NOM 24 IN. (610 MM) DIAM (OR SMALLER) SERVICE WEIGHT (OR HEAVIER) CAST IRON SOIL PIPE, NOM 12 IN.

(305 MM) DIAM (OR SMALLER) OR CLASS 50 (OR HEAVIER) DUCTILE IRON PRESSURE PIPE.

C. CONDUIT - NOM 6 IN. (152 MM) DIAM (OR SMALLER) STEEL CONDUIT OR NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL

ELECTRICAL METALLIC TUBING

D. COPPER TUBING - NOM 6 IN. (152 MM) DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING E. COPPER PIPE - NOM 6 IN. (152 MM) DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE.

F. THROUGH PENETRATING PRODUCT* - FLEXIBLE METAL PIPING - THE FOLLOWING TYPES OF STEEL FLEXIBLE METAL GAS

PIPING MAY BE USED:

1. NOM 2 IN. (51 MM) DIAM (OR SMALLER) STEEL FLEXIBLE METAL GAS PIPING. PLASTIC COVERING ON PIPING MAY OR MAY

NOT BE REMOVED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY.

OMEGA FLEX INC

2. NOM 1 IN. (25 MM) DIAM (OR SMALLER) STEEL FLEXIBLE METAL GAS PIPING. PLASTIC COVERING ON PIPING MAY OR MAY

NOT BE REMOVED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY.

TITEFLEX CORP

A BUNDY CO

3. NOM 1 IN. (25 MM) DIAM (OR SMALLER) STEEL FLEXIBLE METAL GAS PIPING. PLASTIC COVERING ON PIPING MAY OR MAY

NOT BE REMOVED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY.

WARD MFG INC

3. FILL,VOID OR CAVITY MATERIAL* - CAULK OR SEALANT - MIN 5/8. 1-1/4,1-7/8 AND 2-1/2 IN. (16, 32, 48 AND 64 MM) THICKNESS OF CAULK FOR 1, 2, 3 AND 4 HR RATED ASSEMBLIES, RESPECTIVELY, APPLIED WITHIN ANNULUS, FLUSH WITH BOTH SURFACES OF WALL. MIN 1/4 IN. (6 MM) DIAM BEAD OF CAULK APPLIED TO GYPSUM BOARD/PENETRANT INTERFACE AT POINT CONTACT

LOCATION ON BOTH SIDES OF WALL.

THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN

WHICH IT IS INSTALLED, AS SHOWN IN THE FOLLOWING TABLE.

THE HOURLY T RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE TYPE OR SIZE OF THE PIPE OR CONDUIT AND THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, AS TABULATED BELOW:

+WHEN COPPER PIPE IS USED, T RATING IS 0 HR.

3M COMPANY - CP 25WB+ CAULK OR FB-3000 WT SEALANT,

*BEARING THE UL CLASSIFICATION MARKING

SYSTEM NO.W-L-1001

JUNE 15, 2005

F RATINGS - 1, 2, 3 AND 4 HR (SEE ITEMS 2 AND 3)

T RATINGS - 0, 1, 2, 3, AND 4 HR (SEE ITEM 3)

L RATING AT AMBIENT - LESS THAN 1 CFM/SQ FT

L RATING AT 400 F - LESS THAN 1 CFM/SQ FT

MAX PIPE OR

CONDUIT DIAM

IN. (mm)

1 (25) 1 (25) 4 (102) 6 (152)

12 (305)

F RATING

HR

1 OR 2

3 OR 4

1 OR 2

3 OR 4

1 OR 2

T RATING

HR

0+, 1 OR 2

3 OR 4

SECTION A-A

1B

1A 3A

A

1. FLOOR OR WALL ASSEMBLY - LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF OR 1600-2400 KG/M3) CONCRETE. EXCEPT AS NOTED IN TABLE UNDER ITEM 4, MIN THICKNESS OF SOLID CONCRETE FLOOR OR WALL ASSEMBLY IS 4-1/2 IN. (114 MM). FLOOR MAY ALSO BE CONSTRUCTED OF ANY MIN 6 IN. (152 MM) THICK UL CLASSIFIED HOLLOW CORE PRECAST CONCRETE UNITS* . WHEN FLOOR IS CONSTRUCTED OF HOLLOW CORE PRECAST CONCRETE UNITS, PACKING MATERIAL (ITEM 3) AND CAULK FILL MATERIAL (ITEM 4) TO BE INSTALLED SYMMETRICALLY ON BOTH SIDES OF FLOOR, FLUSH WITH FLOOR SURFACE. WALL ASSEMBLY MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE BLOCKS* . MAX DIAM OF OPENING IS IN SOLID LIGHTWEIGHT OR NORMAL WEIGHT CONCRETE. FLOOR IS 32 IN. (813 MM).

MAX DIAM OF OPENING IN FLOOR CONSTRUCTED OF HOLLOW-CORE PRECAST CONCRETE UNITS IS 7 IN. (178 MM).

SEE CONCRETE BLOCKS (CAZT) AND PRECAST CONCRETE UNITS (CFTV) CATEGORIES IN THE FIRE RESISTANCE DIRECTORY FOR NAMES OF

MANUFACTURERS.

1A. STEEL SLEEVE (OPTIONAL, NOT SHOWN) - MAX 15 IN. (381 MM) ID (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL SLEEVE CAST OR GROUTED INTO FLOOR OR WALL ASSEMBLY. SLEEVE MAY EXTEND A MAX OF 2 IN. (51 MM) ABOVE TOP OF FLOOR OR BEYOND EITHER SURFACE OF WALL. MAX 16 IN. (406 MM) ID (OR SMALLER) MIN 0.028 (0.71 MM) WALL THICKNESS (OR HEAVIER) GALVANIZED STEEL SLEEVE CAST OR GROUTED INTO FLOOR OR WALL ASSEMBLY. SLEEVE MAY EXTEND A MAX OF 1/2 IN. (13 MM) BEYOND EITHER SURFACE OF FLOOR OR

WALL.

2. THROUGH PENETRANTS - ONE METALLIC PIPE, CONDUIT OR TUBING TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. MAX ANNULAR SPACE BETWEEN PIPE, CONDUIT OR TUBING AND EDGE OF THROUGH OPENING OR SLEEVE IS DEPENDENT ON THE PARAMETERS SHOWN IN ITEM 4. MIN ANNULAR SPACE BETWEEN PIPE OR CONDUIT AND EDGE OF THROUGH OPENING IS 0 IN. (0 MM) (POINT CONTACT). PIPE CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY. THE

FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED:

A. STEEL PIPE - NOM 30 IN. (762 MM) DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE.

B. IRON PIPE - NOM 30 IN. (762 MM) DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE.

C. CONDUIT - NOM 6 IN. (152 MM) DIAM (OR SMALLER) RIGID STEEL CONDUIT.

D. CONDUIT - NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING.

E. COPPER - TUBING NOM 6 IN. (152 MM) DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBE.

F. COPPER PIPE - NOM 6 IN. (152 MM) DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE.

3. PACKING MATERIAL - POLYETHYLENE BACKER ROD OR NOM 1 IN. (25 MM) THICKNESS OF TIGHTLY-PACKED MINERAL WOOL BATT OR GLASS FIBER INSULATION FIRMLY PACKED INTO OPENING AS A PERMANENT FORM. PACKING MATERIAL TO BE RECESSED FROM TOP SURFACE OF FLOOR OR FROM BOTH SURFACES OF WALL AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF CAULK FILL MATERIAL (ITEM 4).

4. FILL,VOID OR CAVITY MATERIAL* - CAULK OR SEALANT - APPLIED TO FILL THE ANNULAR SPACE FLUSH WITH TOP SURFACE OF FLOOR. IN WALL ASSEMBLIES, REQUIRED CAULK THICKNESS TO BE INSTALLED SYMMETRICALLY ON BOTH SIDES OF WALL, FLUSH WITH WALL SURFACE.

AT POINT CONTACT LOCATION BETWEEN PENETRANT AND SLEEVE OR BETWEEN PENETRANT AND CONCRETE, A MIN 1/4 IN. (6 MM) DIAM BEAD OF CAULK SHALL BE APPLIED AT TOP SURFACE OF FLOOR AND AT BOTH SURFACES OF WALL. THE HOURLY F RATINGS AND THE MIN REQUIRED CAULK THICKNESSES ARE DEPENDENT UPON A NUMBER OF PARAMETERS, AS SHOWN IN THE FOLLOWING TABLE:

(A)MIN 2 IN. (51 MM) THICKNESS OF MINERAL WOOL BATT INSULATION REQUIRED IN ANNULAR SPACE.

(B)MIN 1 IN. (25 MM) THICKNESS OF MINERAL WOOL BATT INSULATION REQUIRED IN ANNULAR SPACE ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY. MIN 1 IN. (25 MM) THICKNESS OF CAULK TO BE INSTALLED FLUSH WITH EACH SURFACE OF FLOOR OR WALL ASSEMBLY.

3M COMPANY - CP 25WB+ CAULK OR FB-3000 WT SEALANT. (NOTE: W RATING APPLIES ONLY WHEN FB-3000 WT SEALANT IS USED.)

*BEARING THE UL CLASSIFICATION MARKING

MIN FLOOR OR

WALL THKNS IN.

(MM)

2-1/2 (64)

2-1/2 (64)

4-1/2 (114)

NOM PIPE TUBE OR

CONDUIT DIAM IN.

(MM)

1/2-12 (13-305)

1/2-12 (13-305)

1/2-6 (13-152)

MAX

ANNULAR

SPACE IN.

(MM)

1-3/8 (35)

3-1/4 (83)

MIN. CAULK

THKNS IN.

(MM)

1/2 (13)

1 (25)

1/4 (6) (a)

System No. C-AJ-1044 June 15, 2005

F Ratings - 2, 3, and 4 Hr (See Items 2A and 4) T Rating - 0 Hr

L Rating At Ambient - 2 CFM/sq ft L Rating At 400 F - less than 1 CFM/sq ft

W Rating - Class I (See Item 4)

SECTION A-A

A

A

F

RATING

HR

1-3/8 (35)

1/2 (13)

1 (25)

1 (25)

1 (25)

2 (51)

1 (25) (b)1-3/8 (35)

3-1/4 (83)

2 (51)

2 (51)

2 (51)

1-1/4 (32)1/2-12 (13-305)

1/2-12 (13-305)

22-30 (558-762)

1/2-20 (13-508)

1/2-6 (13-152)

1/2-20 (13-508)

4-1/2 (114)

4-1/2 (114)

4-1/2 (114)

4-1/2 (114)

4-1/2 (114)

5-1/2 (140)

1. FLOOR OR WALL ASSEMBLY - MIN 4-1/2 IN. (114 MM) THICK LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF OR 1600-2400 KG/M3) CONCRETE. WALL MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE BLOCKS* . MAX

DIAM OF CIRCULAR THROUGH OPENING IS 32-1/2 IN. (826 MM).

SEE CONCRETE BLOCKS (CAZT) CATEGORY IN THE FIRE RESISTANCE DIRECTORY FOR NAMES OF MANUFACTURERS.

1A. STEEL SLEEVE (OPTIONAL, NOT SHOWN) - NOM 12 IN. (305 MM) DIAM (OR SMALLER) SCHEDULE 40 (OR HEAVIER) STEEL PIPE SLEEVE CAST INTO CONCRETE FLOOR OR WALL. SLEEVE TO BE FLUSH WITH OR PROJECT MAX 2 IN.

(51MM) FROM TOP SURFACE OF FLOOR OR FROM BOTH SURFACES OF WALL.

2. THROUGH PENETRANT - ONE METALLIC PIPE, CONDUIT OR TUBING INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN PIPE, CONDUIT OR TUBING AND PERIPHERY OF OPENING SHALL BE MIN OF 0 IN. (0 MM)(POINT CONTACT) TO MAX 1-3/8 IN. (35 MM). PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF

METALLIC PIPES, CONDUITS OR TUBING MAY BE USED:

A. STEEL PIPE - NOM 30 IN. (762 MM) DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE.

A1. IRON PIPE - NOM 30 IN. (762 MM) DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE.

B. CONDUIT - NOM 6 IN. (152 MM) DIAM (OR SMALLER) RIGID STEEL CONDUIT.

C. CONDUIT - NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING.

3. PACKING MATERIAL - POLYETHYLENE BACKER ROD OR NOM 1 IN. (25 MM) THICKNESS OF TIGHTLY-PACKED CERAMIC (ALUMINA SILICA) FIBER BLANKET, MINERAL WOOL BATT OR GLASS FIBER INSULATION MATERIAL USED AS A PERMANENT FORM. PACKING MATERIAL TO BE RECESSED FROM TOP SURFACE OF FLOOR OR FROM BOTH SURFACES OF SOLID CONCRETE OR CONCRETE BLOCK WALL AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF CAULK FILL MATERIAL (ITEM 4). AS AN ALTERNATE WHEN MAX PIPE SIZE IS 10 IN. (254 MM) DIAM AND WHEN MAX ANNULAR SPACE IS 1 IN. (25 MM), A MIN 1 IN. (25 MM) THICKNESS OF TIGHTLY-PACKED CERAMIC FIBER BLANKET OR MINERAL WOOL BATT PACKING MATERIAL MAY BE RECESSED MIN 1/2 IN. (13 MM) FROM BOTTOM SURFACE OF FLOOR

OR FROM EITHER SIDE OF SOLID CONCRETE WALL.

4. FILL,VOID OR CAVITY MATERIALS* - CAULK OR SEALANT - APPLIED TO FILL THE ANNULAR SPACE TO THE MIN

THICKNESS SHOWN IN THE FOLLOWING TABLE:

(A) BR = POLYETHYLENE BACKER ROD.

CF = CERAMIC FIBER BLANKET.

GF = GLASS FIBER INSULATION.

MW = MINERAL-WOOL BATT.

(B) CAULK INSTALLED FLUSH WITH TOP SURFACE OF FLOOR OR BOTH SURFACES OF WALL.

(C) CAULK INSTALLED FLUSH WITH BOTTOM SURFACE OF FLOOR OR ONE SURFACE OF SOLID (NON- CONCRETE

BLOCK) WALL.

3M COMPANY - CP 25WB+ CAULK OR FB-3000 WT SEALANT.

(NOTE: W RATING APPLIES ONLY WHEN FB-3000 WT SEALANT IS USED.)

*BEARING THE UL CLASSIFICATION MARKING

MAX PIPE DIAM

IN. (MM)

10 (254)

10 (254)

30 (762)

MAX ANNULAR

SPACE IN. (MM)

1 (25)

1 (25)

2-1/2 (64)

PACKING MATL

TYPE (a)

BR, CF, GF OR MW

CF OR MW

BR, CF, GF OR MW

MIN. CAULK THKNS

IN. (MM)

1/2 (13) (b)

1/2 (13) (c)

1 (25) (b)

System No. C-AJ-1001 June 15, 2005 F Rating - 3 Hr T Rating - 0 Hr

W Rating - Class I (See Item 4)

SECTION A-A

4 4 1

A

A

T-501

TECHNOLOGY DETAILS

3 UL PENETRATION DETAIL W-L-1001

No Scale

1 UL PENETRATION DETAIL C-AJ-1001

No Scale

2 UL PENETRATION DETAIL C-AJ-1044

No Scale

VA PROJECT NUMBER

Building Number

Drawing Number

Project Title

Date Checked Drawn

Drawing Title

Approved:

VA FORM 08-6231

A

B C

D E

21 4 5 6 7

321 4 5 6 7

A B

C E

Dwg. of

LocationLocation

Office of Construction and Facilities Management

PROJECT MANAGER: ACG Project Number

Revisions: Date

CONSULTANTS:

OCTOBER 24, 2022 ADRKTK

658-20-10520-210

CONSTRUCTION DOCUMENTS - FOR CONSTRUCTION

FULLY SPRINKLERED

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A. 34Engineers Architects

U.S. Department of Veterans Affairs

FACILITY WIDE SECURITY

CAMERAS UPGRADE

SALEM VA MEDICAL CENTER

1970 ROANOKE BLVD.

SALEM, VA 24153

1, 2, 2A, 4, 5, 7, 8, 9, 10, 11, 12, 14,17, 74, 75, 76, 77, 143, 170, PARKING LOTS B, C, F, H, K, N, Q, R, T, V, X, AND VP

DocuSign Envelope ID: 3ADC3376-EFA9-4753-9EE8-D15D0B94D50D

EXISTING CONCRETE POLE BASE

GRADE

REPLACE EXISTING CAMERA WITH NEW CCTV

CAMERA AND MOUNTING BRACKET TO BE

FURNISHED AND INSTALLED BY CCTV INSTALLER.

COORDINATE MOUNTING REQUIREMENTS WITH

CCTV INSTALLER.

CCTV CAMERA CABLING TO BE RUN INSIDE POLE BY

CONTRACTOR. COORDINATE ANY REQUIREMENTS WITH

CCTV INSTALLER. EC TO PROVIDE A PULL WIRE FROM

HANDHOLE TO DRILLED HOLE AT CAMERA LOCATION.

ELECTRICAL CONTRACTOR SHALL FIELD DRILL 1-1/2"

DIAMETER HOLE IN POLE FOR CAMERA CABLING.

COORDINATE EXACT HEIGHT WITH CAMERA MOUNT.

ROUTE FIBER CABLE INSIDE OF EXISTING POLE BASE

AND EXISTING POLE.

INSTALL NEMA 3R ENCLOSURE ONTO EXTERIOR OF

EXISTING LIGHT POLE. SEE DETAIL 6/T-502 FOR MORE

INFORMATION.

EXISTING POLE LIGHT

EXISTING POLE HANDHOLE

EXISTING 120V NON-GFI

POWER. RUN CONCEALED

INSIDE OF LIGHT POLE.

REMOVE EXISTING CABLE FROM CONDUIT BACK TO

SOURCE, THEN INSTALL NEW FIBER IN EXISTING

CONDUIT.

NOTES:

1. CONTRACTOR TO REMOVE EXISTING CAMERA AND EXISTING CABLING SERVING CAMERA AND INSTALL NEW CAMERA/CABLING SO THAT AT NO TIME SHALL SURVEILLANCE BE LOST FOR MORE THAN 4 HOURS. COORDINATE ALL DOWNTIME AND SCHEDULING WITH COR

PRIOR TO ANY WORK BEING DONE.

2. USE EXISTING CABLE AS PULL STRING FOR NEW FIBER CABLE.

TAP/SPLICE EXISTING 120V CIRCUIT TO SUPPLY POWER TO

FIBER TO ETHERNET CONVERTER.

LICENSE PLATE CAMERA

MEDIA

CONVERTER AT

LIGHT POLE

120V POWER SUPPLY

DEPENDANT ON

FIBER AND MODEL

NETWORK SWITCH

OWNER'S NETWORK FIBER

SWITCH

CAT 6A CABLE

CAT 6A CABLE

MEDIA CONVERTER

IN IT ROOM

OR FIBER DIRECTLY

FROM A FIBER SWITCH

FE EF

MULTI-SENSOR CAMERA

120V POWER SUPPLY

PoE MID-SPAN

DEVICE

A.

DETAIL NOTES :

ALL EQUIPMENT AND INSTALLATION SHALL BE APPROVED BY VAMC

IT DEPARTMENT.

(1) 4 PR UTP

DATA

CABLE/JACK

(1) 4 PR UTP

TELEPHONE

CABLE/JACK

1/2" HIGH BLACK LETTERS

ON CLEAR BACKGROUND,

PANDUIT OR EQUAL ON

PERMANENT LABEL,

TYPICAL.

XXX

XXX

B B

T T

BLANK

SINGLE GANG COVER

PLATE WITH 6 OUTLETS

(TYPICAL). LOCATIONS

AS SHOWN ON PLANS

TELE/DATA (TYP.) ( 4)

(1) 4 PR UTP

TELEPHONE

CABLE/JACK

C C

(1) 4 PR UTP

DATA CABLE/JACK

BLANK

FINISHED FLOOR

MOUNTING HEIGHT AS

SHOWN IN DRAWINGS

4-11/16" SQ. BY 2-1/2"

DEEP BOX WITH SINGLE

GANG 5/8" TILE RING.

1-1/4" CONDUIT WITH

COMMUNICATIONS WIRING

WALL

CORRIDORROOM

6" MIN NYLON BUSHING

COORDINATE WITH DUCTWORK

EXTEND CONDUIT TO ABOVE

FINISHED ACCESSABLE

CEILING IN CORRIDOR TO

CABLE TRAY UNLESS NOTED

OTHERWISE.

SUSPENDED LAY-IN

CEILING

A.

B.

C.

D.

E.

F.

G.

DETAIL NOTES:

ALL CONNECTIONS TO THE PBB AND SBB SHALL BE MADE

WITH COMPRESSION STYLE LONG BARREL CONNECTORS

ON THE CONDUCTOR AND 2-LUG BOLTED CONNECTIONS TO

THE GROUNDING BUS BARS. CONNECTIONS TO STEEL

SHALL BE WITH SILICON BRONZE HARDWARE. CONNECTION

TO SLEEVES OR CONDUITS SHALL BE BY AN APPROVED

GROUNDING BUSHING.

LOCATE PBB AND SBB ON THE LEFT OF THE TTB AND 12"

AFF.

ALL CONDUCTORS USED FOR GROUNDING SHALL BE

MARKED AT CONNECTION POINT AND EVERY TWENTY FEET

(20') THEREAFTER WITH A LABEL IDENTIFYING IT AS THE

TELECOMMUNICATIONS GROUNDING BACKBONE (TBB). USE

PANDUIT #LTYK OR APPROVED EQUIVALENT.

REFERENCE SPECIFICATIONS REGARDING PBB.

REFERENCE SPECIFICATIONS REGARDING SBB.

CONTRACTOR SHALL CLEAN THE GROUNDING BUS BAR

AND APPLY ANTI-OXIDANT PRIOR TO FASTENING THE

CONNECTORS TO THE GROUNDING BUS BAR.

ALL COPPER BACKBONE CABLING SHALL MEET THE

REQUIREMENTS OF TIA/EIA 568-C FOR RISER CABLE.

C O

M M

. E Q

U

IP

M

EN

T/ R

AC

KS

M

ET

AL

S

LE

EV

ES

(W

IT

H

IN

C

O M

M . R

M

ST

R

U C

TU

R

AL

S

TE

EL

BA

SK

ET

/C

AB

LE

T R

AY

G R

O U

N D

L O

O P

PRIMARY

PBB

TR-#1

SBB

COMM. EQUIPMENT/RACKS (RBB)

ELECTRICAL PANEL

STRUCTURAL STEEL

CABLE TRAY

TR-#2

SBB

COMM. EQUIPMENT/RACKS (RBB)

ELECTRICAL PANEL

STRUCTURAL STEEL

CABLE TRAY

PROVIDE 6 AWG

CONDUCTOR, EACH RUN

PROVIDE 1/0 AWG CONDUCTOR

TO PBB FOR EACH SBB.

PROVIDE 2/0 AWG

CONDUCTOR TO GROUND

RING FOR ELECTRICAL

SYSTEM

PROVIDE 1/0 AWG

CONDUCTOR TO PBB

FOR EACH TGB

EL

EC

TR

IC

AL

P

AN

EL

LADDER TRAY

LADDER TRAY

ONMICONVERTER

PoE MEDIA

CONVERTER "FE"

WITH TWO - PoE

PORTS. 1 FOR

LICENSE PLATE

CAMERA AND 1 FOR

PoE MID-SPAN

DEVICE. PROVIDE

WITH INCOMING

FIBER PATCH PORTS.

18"W X 18"H X 8" D NEMA 3R

ENCLOSURE WITH HINGED,

LOCKABLE COVER AND

BACKPLANE

QUAD RECEPTACLES

CONDUIT & WIRING FOR 120V

CIRCUIT. CONTRACTOR TO

CONNECT TO POLE LIGHT

120V CIRCUIT.

FE

60 WATT PoE MID-SPAN

DEVICE FOR

MULTI-SENSOR CAMERA

CAT 6A CABLE

CAT 6A CABLE UP

TO NEW CAMERAS

INCOMING FIBER OPTIC

CABLING FROM IT ROOM.

SEE DETAIL 7/T-502 FOR

ADDITIONAL INFORMATION.

10"

4"

1/4"

3/16" DIAMETER, TYP. FOR 6

1/4" DIAMETER, TYP. FOR 12

TMGB & TGB

1 TELECOM ROOM OPPER GOUND BAR, 1/4" x 4" x 10", HOLE CENTERS TO MATCH NEMA DOUBLE

LUG CONFIGURATION.

STANDOFF BRACKET ASSEMBLY WITH INSULATORS, TYP. FOR 2.

LOCK WASHER, TYPICAL FOR 2.

ANCHOR BOLTS, TYPICAL FOR 2.

A CONTINUOUS #1/0 GREEN INSULATED CONDUCTOR SHALL BE RUN

FROM SERVICE GROUND AT TMGB. BOND NCE CABINET WITH #4 GREEN INSULATED

CONDUCTOR.

T-502

TECHNOLOGY DETAILS

VA PROJECT NUMBER

Building Number

Drawing Number

Project Title

Date Checked Drawn

Drawing Title

Approved:

VA FORM 08-6231

A

B C

D E

21 4 5 6 7

321 4 5 6 7

A B

C E

Dwg. of

LocationLocation

Office of Construction and Facilities Management

PROJECT MANAGER: ACG Project Number

Revisions: Date

CONSULTANTS:

OCTOBER 24, 2022 ADRKTK

658-20-10520-210

CONSTRUCTION DOCUMENTS - FOR CONSTRUCTION

FULLY SPRINKLERED

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A. 34Engineers Architects

U.S. Department of Veterans Affairs

FACILITY WIDE SECURITY

CAMERAS UPGRADE

SALEM VA MEDICAL CENTER

1970 ROANOKE BLVD.

SALEM, VA 24153

1, 2, 2A, 4, 5, 7, 8, 9, 10, 11, 12, 14,17, 74, 75, 76, 77, 143, 170, PARKING LOTS B, C, F, H, K, N, Q, R, T, V, X, AND VP

5 NEW EXTERIOR CCTV CAMERA MOUNTED ON EXISTING POLE DETAIL

No Scale

7 FIBER TO ETHERNET CONVERSION DETAIL

No Scale

3 TELECOMMUNICATIONS FACEPLATES

No Scale

1 TELECOMMUNICATIONS OUTLET INSTALLATION DETAIL

No Scale

4 TELECOMMUNICATIONS GROUNDING BAR DETAIL

No Scale

6 TYPICAL EXTERIOR FIBER TO ETHERNET ENCLOSURE DETAIL

No Scale

2 TYPICAL SBB WALL MOUNT DETAIL

No Scale

DocuSign Envelope ID: 3ADC3376-EFA9-4753-9EE8-D15D0B94D50D

4" SQ. JUNCTION BOX WITH SINGLE GANG MUD RING (BYEC)

FLAT WALL BRACKET TYPE FOR WALL MOUNTED

APPLICATIONS. UTILIZE CORNER MOUNT BRACKET FOR

CAMERAS LOCATED ON BUILDING CORNERS.

18.24

8.75

1.68

3.64

7.75

11.75

7.00

3.94

11.74

7.75

8.74

1.68

1.68

2.50

3.82

10.23

7.75

11.73

7.75

11.24

4.38

1.73

4" SQ. JUNCTION BOX

WITH SINGLE GANG

MUD RING (BYEC)

333 [13.1]

545 [21.5]

193 [7.6]

264 [10.4]

4" SQ. JUNCTION BOX WITH SINGLE GANG MUD RING (BYEC)

FLAT WALL BRACKET TYPE FOR WALL MOUNTED

APPLICATIONS. UTILIZE CORNER MOUNT BRACKET FOR

CAMERAS LOCATED ON BUILDING CORNERS.

4" SQ. JUNCTION BOX WITH SINGLE

GANG MUD RING (BYEC)

T-503

TECHNOLOGY DETAILS

VA PROJECT NUMBER

Building Number

Drawing Number

Project Title

Date Checked Drawn

Drawing Title

Approved:

VA FORM 08-6231

A

B C

D E

21 4 5 6 7

321 4 5 6 7

A B

C E

Dwg. of

LocationLocation

Office of Construction and Facilities Management

PROJECT MANAGER: ACG Project Number

Revisions: Date

CONSULTANTS:

OCTOBER 24, 2022 ADRKTK

658-20-10520-210

CONSTRUCTION DOCUMENTS - FOR CONSTRUCTION

FULLY SPRINKLERED

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A. 34Engineers Architects

U.S. Department of Veterans Affairs

FACILITY WIDE SECURITY

CAMERAS UPGRADE

SALEM VA MEDICAL CENTER

1970 ROANOKE BLVD.

SALEM, VA 24153

1, 2, 2A, 4, 5, 7, 8, 9, 10, 11, 12,…

This is the start of the file's text. The full file is on GovTribe.