S02 Salem Facility Wide Security Camera Upgrade Drawings 31-40.pdf
PDF 5 MB Posted
- Attached to
- Z1DA--Facility Wide Security Camera Upgrades Federal contract opportunity
- Solicitation number
- 36C24623B0019
About this file
This is a solicitation for a facility-wide security camera upgrade project at the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6. The project involves installing new security cameras at multiple buildings and parking lots at the Salem VA Medical Center campus. Key details include the requirement for IP-based cameras and associated equipment from Avigilon, with fiber optic cabling for runs over 295 feet. The contractor must coordinate all work with the Contracting Officer Representative and minimize any disruption to existing surveillance. The period of performance is one year from NTP.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24623B0019 0004_1.docx | DOCX document | |
| S05 36C24623B0019 Facility Wide Security Camera Upgrade Questions 3-20-2023.pdf | ||
| S06 36C24623B0019 0004.pdf | ||
| S06_36C24623B0019 0003.pdf | ||
| 36C24623B0019 0003_1.docx | DOCX document | |
| S02_ 0002_36C24623B0019 0002.pdf | ||
| 36C24623B0019 0002_1.docx | DOCX document | |
| 36C24623B0019 0001_1.docx | DOCX document | |
| S06_36C24623B0019 0001.pdf | ||
| S02 Salem Facility Wide Security Camera Upgrade Drawings 21-30.pdf | ||
| S02 Salem Facility Wide Security Camera Upgrade Drawings1-10.pdf | ||
| S02 Salem Facility Wide Security Camera Upgrade Specs.pdf | ||
| S02 36C24623B0019_1 Fac. Wide Cameras.pdf | ||
| S02 Salem Facility Wide Security Camera Upgrade Drawings11-20.pdf | ||
| 36C24623B0019_2.docx | DOCX document |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CHASE
FP
FP
ELECTRICAL
STORAGE
LOCKSMITH
OFFICE
15A
15B
15D
CARPENTRY SHOP
BREAK RM
15C
STORAGE
2A
STORAGE
2B
LOUNGE
SD4B-76
ELECTRICAL SHOP
OFFICE
4A
IT
STORAGE
CARPENTRY
STORAGE
UTILITY
RM
STORAGE
10B1010A
WOMENS
TOILET
9A
ELECTRONIC SHOP
9ELECTRIC STORAGE
MULTI PURPOSE
5A
SIGN SHOP
6A
STORAGE
5B
ELEVATOR STORAGE
1A
CORRIDOR
CORRIDOR
CORR.
CORRIDOR
STAIR
STAIR
LOCKSMITH
STORAGE
1C
ELECTRICAL SHOP
MECHANICAL
EXISTING PANEL -
PANEL '76-BS1'
'76-BS1' - 1
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
321 4 5 6 7
A B
C E
Dwg. of
LocationLocation
Office of Construction and Facilities Management
PROJECT MANAGER: ACG Project Number
Revisions: Date
CONSULTANTS:
OCTOBER 24, 2022 ADRKTK
658-20-10520-210
CONSTRUCTION DOCUMENTS - FOR CONSTRUCTION
FULLY SPRINKLERED
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A. 34Engineers Architects
U.S. Department of Veterans Affairs
FACILITY WIDE SECURITY
CAMERAS UPGRADE
SALEM VA MEDICAL CENTER
1970 ROANOKE BLVD.
SALEM, VA 24153
CAMERA SYMBOL LEGENDCAMERA SYMBOL LEGEND
SYMBOL HEIGHT DESCRIPTION
CCTV FISH EYE
(WP-WEATHER PROOF)
TYPE
12 MP
H4F-DO1-IR
5 MP H5A
24 MP
24C-H4A-3MH
CCTV FIXED DOME
(WP-WEATHER PROOF)
6 MP H5A
360 32 MP
32C-H4A-4MH
3 MP
H4 LPC
FE
MANUFACTURER
AVIGILON
TOTAL
DEVICES
AVIGILON
AVIGILON
AVIGILON
AVIGILON
AVIGILON
AVIGILON
CCTV FIXED DOME
(WP-WEATHER PROOF)
CCTV MULTISENSOR
(WP-WEATHER PROOF)
CCTV MULTISENSOR
(WP-WEATHER PROOF)
CCTV MULTISENSOR
(WP-WEATHER PROOF)
CCTV MULTISENSOR
(WP-WEATHER PROOF)
CCTV LICENSE PLATE
(WP-WEATHER PROOF)
24 MP
24C-H4A-3MH
24 MP
24C-H4A-3MH
D6
360L
CAMERA ABBREVIATIONS
N
RP
RV
WP
PROVIDE AND INSTALL NEW CAMERA
REPLACE EXISTING CAMERA WITH NEW CAMERA
REMOVE EXISTING CAMERA
WEATHER PROOF
SPECIAL NOTE
ALL CAMERAS LOCATED ON THE EXTERIOR OF THE
BUILDING ARE SHOWN ON SHEET TS101 UNLESS
NOTED OTHERWISE.
WALL RATINGS LEGEND:
SMOKE WALLS S S S
1 HOUR FIRE WALL
S
2 HOUR FIRE WALL
3 HOUR FIRE WALL
D5
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
AVIGILON
76TK101
BUILDING 76 BASEMENT FLOOR
SECURITY PLAN
1 BUILDING 76 BASEMENT FLOOR SECURITY PLAN
1/8" = 1'-0"
00 4 8 16
NORTH
SHEET NOTES:
SHEET KEY NOTES:X
A. NO INTERIOR CAMERAS TO BE REMOVED,
REPLACED, OR ADDED. REFERENCE SHEET
TS101 FOR EXTERIOR CAMERA LOCATIONS.
B. CCTV SERVICES ARE TO REMAIN ACTIVE
OUTSIDE AREAS UNDER ACTIVE CONSTRUCTION
AT ALL TIMES. RETAIN SERVICES TO SYSTEMS
DURING DEMOLITION AND REMODEL OF THE
RESPECTIVE AREAS.
C. ALL EXISTING CONDITIONS ARE BASED ON THE
BEST AVAILABLE INFORMATION AT THE TIME OF
SURVEY AND VISUAL INSPECTION. VERIFY
EXISTING CONDITIONS.
D. NEW CCTV CABLING TO BE RUN ON J-HOOKS 2'
OC ABOVE CEILING IN CORRIDORS.
E. ALL CONDUIT SECURITY JUNCTION BOXES AND
RACEWAY PROVIDED BY EC UNO. ALL CONDUIT
SHALL BE 3/4" MINIMUM. EC TO SIZE CONDUIT
PER THE MOST CURRENT EDITION OF THE NEC.
F. WHERE LENGTH FROM CAMERA TO RACK
EQUIPMENT EXCEED 295' (90M) CONTRACTOR
SHALL USE FIBER OPTIC CABLE AS ILLUSTRATED
IN DETAIL 7/T-502.
G. COORDINATE AND CONFIRM ALL ROUTING WITH
COR PRIOR TO ROUGH-IN.
1. EXISTING WALL MOUNTED PATCH PANELS AND
SWITCHES.
2. PROPOSED LOCATION FOR NEW PoE MID-SPAN
DEVICE AND NEW WALL MOUNTED SHELF. MOUNT
SHELF BELOW OTHER WALL MOUNTED
EQUIPMENT (COORDINATE LOCATION WITH COR
AND OIT REPRESENTATIVE). PROVIDE NEW,
FLOOR MOUNTED UPS CLOSE ENOUGH FOR PoE
MID-SPAN DEVICE TO PLUG INTO UPS.
COORDINATE WITH PoE MID-SPAN DEVICE
MANUFACTURER FOR POWER CORD LENGTH.
REFERENCE 2/T-602 FOR MORE INFORMATION.
3. PROVIDE POWER OUTLET FOR NEW CCTV
EQUIPMENT. INSTALL POWER OUTLET WITHIN 5
FEET OF NEW UPS LOCATION.
4. REMOVE EXISTING CAMERA FIELD DISTRIBUTION
BOX AND ENCODER. SURRENDER EQUIPMENT TO
THE POLICE.
5. PROVIDE NEW 1P, 20A CIRCUIT BREAKER IN
EXISTING PANEL FOR NEW RECEPTACLE IN IT
ROOM 21.
6. PROVIDE NEW 4", UL LISTED SLEEVE.
DocuSign Envelope ID: 3ADC3376-EFA9-4753-9EE8-D15D0B94D50D
10/26/2022
MECH
FP
CLOSET
13C
HOUSE KEEPING
FP
OFFICE
SUPPLIES
13P
STORAGE
13J
HC TOILET
12H
RECEPTION
12Q
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
EMS
OFFICE
OFFICE
OFFICE
8A
TOILET
9B
EMS
STORAGE
SOILED LINEN
BIO-HAZARD
9A
EMS
STORAGE
STAIR CORRIDOR
OFFICE
12A
LOAN
12B
RECORDS
12C
WORK RM
12D
OFFICE
12E
CHIEF
12F LOUNGE
12G
SUPPLIES
12J
ACCNT
12K
SHARE
DRAFT
12L
LOAN
12M
LOAN
12N
OFFICE
12P
MECH
12R
CORRIDOR
OFFICE
13A
OFFICE
NEW
ACCOUNTS
13B
HAC
13D
LOBBY
VESTIBULE
13E
TELLER AREA
13F
WORK RM
13H
WORK
RM
13K
HC TOILET
13M
EMS
OFFICE
15C
OFFICE
15D15E
OFFICE
15F
ELEVATOR
EMS STORAGE
TOILET
1AELEVATOR
SERVICE
RM
2C
GENERAL
EQUIPMENT
STORAGE
2A
EMS
STORAGE
PAINT
SHOP
OFFICE
2B4A
4E
PAINT SHOP
4C
PAINT SHOP
4B
PAINT SHOP
TOILET
4D
STAIR
OFFICE
5A
TOILET
5B
GIP
STORAGE
OFFICE
5C
13G
OFFICE
OFFICE
2 4
1 3
'77-XF' -
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
321 4 5 6 7
A B
C E
Dwg. of
LocationLocation
Office of Construction and Facilities Management
PROJECT MANAGER: ACG Project Number
Revisions: Date
CONSULTANTS:
OCTOBER 24, 2022 ADRKTK
658-20-10520-210
CONSTRUCTION DOCUMENTS - FOR CONSTRUCTION
FULLY SPRINKLERED
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A. 34Engineers Architects
U.S. Department of Veterans Affairs
FACILITY WIDE SECURITY
CAMERAS UPGRADE
SALEM VA MEDICAL CENTER
1970 ROANOKE BLVD.
SALEM, VA 24153
CAMERA SYMBOL LEGENDCAMERA SYMBOL LEGEND
SYMBOL HEIGHT DESCRIPTION
CCTV FISH EYE
(WP-WEATHER PROOF)
TYPE
12 MP
H4F-DO1-IR
5 MP H5A
24 MP
24C-H4A-3MH
CCTV FIXED DOME
(WP-WEATHER PROOF)
6 MP H5A
360 32 MP
32C-H4A-4MH
3 MP
H4 LPC
FE
MANUFACTURER
AVIGILON
TOTAL
DEVICES
AVIGILON
AVIGILON
AVIGILON
AVIGILON
AVIGILON
AVIGILON
CCTV FIXED DOME
(WP-WEATHER PROOF)
CCTV MULTISENSOR
(WP-WEATHER PROOF)
CCTV MULTISENSOR
(WP-WEATHER PROOF)
CCTV MULTISENSOR
(WP-WEATHER PROOF)
CCTV MULTISENSOR
(WP-WEATHER PROOF)
CCTV LICENSE PLATE
(WP-WEATHER PROOF)
24 MP
24C-H4A-3MH
24 MP
24C-H4A-3MH
D6
360L
CAMERA ABBREVIATIONS
N
RP
RV
WP
PROVIDE AND INSTALL NEW CAMERA
REPLACE EXISTING CAMERA WITH NEW CAMERA
REMOVE EXISTING CAMERA
WEATHER PROOF
SPECIAL NOTE
ALL CAMERAS LOCATED ON THE EXTERIOR OF THE
BUILDING ARE SHOWN ON SHEET TS101 UNLESS
NOTED OTHERWISE.
WALL RATINGS LEGEND:
SMOKE WALLS S S S
1 HOUR FIRE WALL
S
2 HOUR FIRE WALL
3 HOUR FIRE WALL
D5
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
AVIGILON
77TK101
BUILDING 77 BASEMENT FLOOR
SECURITY PLAN
1 BUILDING 77 BASEMENT FLOOR SECURITY PLAN
1/8" = 1'-0"
00 4 8 16
NORTH
SHEET NOTES:
SHEET KEY NOTES:X
A. NO INTERIOR CAMERAS TO BE REMOVED,
REPLACED, OR ADDED. REFERENCE SHEET
TS101 FOR EXTERIOR CAMERA LOCATIONS.
B. CCTV SERVICES ARE TO REMAIN ACTIVE
OUTSIDE AREAS UNDER ACTIVE CONSTRUCTION
AT ALL TIMES. RETAIN SERVICES TO SYSTEMS
DURING DEMOLITION AND REMODEL OF THE
RESPECTIVE AREAS.
C. ALL EXISTING CONDITIONS ARE BASED ON THE
BEST AVAILABLE INFORMATION AT THE TIME OF
SURVEY AND VISUAL INSPECTION. VERIFY
EXISTING CONDITIONS.
D. NEW CCTV CABLING TO BE RUN ON J-HOOKS 2'
OC ABOVE CEILING IN CORRIDORS.
E. ALL CONDUIT SECURITY JUNCTION BOXES AND
RACEWAY PROVIDED BY EC UNO. ALL CONDUIT
SHALL BE 3/4" MINIMUM. EC TO SIZE CONDUIT
PER THE MOST CURRENT EDITION OF THE NEC.
F. WHERE LENGTH FROM CAMERA TO RACK
EQUIPMENT EXCEED 295' (90M) CONTRACTOR
SHALL USE FIBER OPTIC CABLE AS ILLUSTRATED
IN DETAIL 7/T-502.
G. COORDINATE AND CONFIRM ALL ROUTING WITH
COR PRIOR TO ROUGH-IN.
1. PROVIDE NEW 4", UL LISTED SLEEVE.
2. PROPOSED LOCATION FOR NEW PoE MID-SPAN
DEVICE, AND SHELF, MOUNTED IN EXISTING, WALL
MOUNTED DATA RACK (VERIFY LOCATION WITH
COR AND OIT REPRESENTATIVE). PROVIDE NEW,
FLOOR MOUNTED UPS CLOSE ENOUGH FOR PoE
MID-SPAN DEVICE TO PLUG INTO UPS.
COORDINATE WITH PoE MID-SPAN DEVICE
MANUFACTURER FOR POWER CORD LENGTH.
REFERENCE 2/T-602 FOR MORE INFORMATION.
3. PROVIDE POWER OUTLET FOR NEW CCTV
EQUIPMENT. INSTALL POWER OUTLET WITHIN 5
FEET OF NEW UPS LOCATION.
4. REMOVE EXISTING CAMERA FIELD DISTRIBUTION
BOX AND ENCODER. SURRENDER EQUIPMENT TO
THE POLICE.
5. ELECTRICAL ROOM ON SECOND FLOOR STACKED
OVER THIS AREA.
DocuSign Envelope ID: 3ADC3376-EFA9-4753-9EE8-D15D0B94D50D
EXISTING PANEL
- PANEL '77-XF'
SHEET NOTES:
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
321 4 5 6 7
A B
C E
Dwg. of
LocationLocation
Office of Construction and Facilities Management
PROJECT MANAGER: ACG Project Number
Revisions: Date
CONSULTANTS:
OCTOBER 24, 2022 ADRKTK
658-20-10520-210
CONSTRUCTION DOCUMENTS - FOR CONSTRUCTION
FULLY SPRINKLERED
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A. 34Engineers Architects
U.S. Department of Veterans Affairs
FACILITY WIDE SECURITY
CAMERAS UPGRADE
SALEM VA MEDICAL CENTER
1970 ROANOKE BLVD.
SALEM, VA 24153
CAMERA SYMBOL LEGENDCAMERA SYMBOL LEGEND
SYMBOL HEIGHT DESCRIPTION
CCTV FISH EYE
(WP-WEATHER PROOF)
TYPE
12 MP
H4F-DO1-IR
5 MP H5A
24 MP
24C-H4A-3MH
CCTV FIXED DOME
(WP-WEATHER PROOF)
6 MP H5A
360 32 MP
32C-H4A-4MH
3 MP
H4 LPC
FE
MANUFACTURER
AVIGILON
TOTAL
DEVICES
AVIGILON
AVIGILON
AVIGILON
AVIGILON
AVIGILON
AVIGILON
CCTV FIXED DOME
(WP-WEATHER PROOF)
CCTV MULTISENSOR
(WP-WEATHER PROOF)
CCTV MULTISENSOR
(WP-WEATHER PROOF)
CCTV MULTISENSOR
(WP-WEATHER PROOF)
CCTV MULTISENSOR
(WP-WEATHER PROOF)
CCTV LICENSE PLATE
(WP-WEATHER PROOF)
24 MP
24C-H4A-3MH
24 MP
24C-H4A-3MH
D6
360L
CAMERA ABBREVIATIONS
N
RP
RV
WP
PROVIDE AND INSTALL NEW CAMERA
REPLACE EXISTING CAMERA WITH NEW CAMERA
REMOVE EXISTING CAMERA
WEATHER PROOF
SPECIAL NOTE
ALL CAMERAS LOCATED ON THE EXTERIOR OF THE
BUILDING ARE SHOWN ON SHEET TS101 UNLESS
NOTED OTHERWISE.
WALL RATINGS LEGEND:
SMOKE WALLS S S S
1 HOUR FIRE WALL
S
2 HOUR FIRE WALL
3 HOUR FIRE WALL
D5
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
AVIGILON
77TK121
BUILDING 77 SECOND FLOOR
SECURITY PLAN
1 BUILDING 77 SECOND FLOOR SECURITY PLAN
1/8" = 1'-0"
00 4 8 16
NORTH
SHEET KEY NOTES:X
A. NO INTERIOR CAMERAS TO BE REMOVED,
REPLACED, OR ADDED. REFERENCE SHEET
TS101 FOR EXTERIOR CAMERA LOCATIONS.
B. CCTV SERVICES ARE TO REMAIN ACTIVE
OUTSIDE AREAS UNDER ACTIVE CONSTRUCTION
AT ALL TIMES. RETAIN SERVICES TO SYSTEMS
DURING DEMOLITION AND REMODEL OF THE
RESPECTIVE AREAS.
C. ALL EXISTING CONDITIONS ARE BASED ON THE
BEST AVAILABLE INFORMATION AT THE TIME OF
SURVEY AND VISUAL INSPECTION. VERIFY
EXISTING CONDITIONS.
D. NEW CCTV CABLING TO BE RUN ON J-HOOKS 2'
OC ABOVE CEILING IN CORRIDORS.
E. ALL CONDUIT SECURITY JUNCTION BOXES AND
RACEWAY PROVIDED BY EC UNO. ALL CONDUIT
SHALL BE 3/4" MINIMUM. EC TO SIZE CONDUIT
PER THE MOST CURRENT EDITION OF THE NEC.
F. WHERE LENGTH FROM CAMERA TO RACK
EQUIPMENT EXCEED 295' (90M) CONTRACTOR
SHALL USE FIBER OPTIC CABLE AS ILLUSTRATED
IN DETAIL 7/T-502.
G. COORDINATE AND CONFIRM ALL ROUTING WITH
COR PRIOR TO ROUGH-IN.
1. PROVE NEW 1P, 20A CIRCUIT BREAKER FOR NEW
OUTLET IN BASEMENT IT ROOM 4A.
DocuSign Envelope ID: 3ADC3376-EFA9-4753-9EE8-D15D0B94D50D
TO
B
LD
G
TUNNEL BELOW GRADE
FIRE PROTECTION
SUPPLY PROCESSING AND
DISTRIBUTION
SPD
SCISSOR LIFT MOTOR
ROLL UP DOOR ROLL UP DOORROLL UP DOOR
DOCK LEVELLER DOCK LEVELLER
PIT BELOW 1' 2" WIDE AND 1' 6" DEEP
SIM TO DET. 3/UT-A4
REMOVABLE GAL. STEEL
GRATING W/BEARING BAR
SCISSOR LIFT UP DOWN
PUSH BUTTON CONTROL
4' 0" ABOVE FIN. FLOOR
TO BLDG 2A
INFORMATION
DESK
ICE
MACH
FP
TO BLDG 5
WASHERAREA
HOLDING
STEAMER
STAINLESS STEEL
STERID UNIT
CONVEYOR BELT
FEC
CLEAN
SUPPLY
BB-140
CLEAN
LINEN
BG-115H
TELE
BF-110A
ELE/
MECH
BE-103A
CORR.
CB-52
TOILET
BG-115A
MEDICINE
RM
BG-131A
TELE.
BB-162
TELEBB-
140A
FP
BA-103A
TOILET
BB-121
EQUIP.
STOR.
CORR.CB-29D
PRESCR REC
BF-104
PRESSURE
RM
TOILET
BF-113
HAC HOUSE
KEEPING
BF-112
TELE
BF-114
ELECTRICAL
BF-115
FP
TLT/ LKR
BE-116
SHOWER
BE-116A
CORR.
CB-35A
MECH RM
BE-114
MED
GAS
BE-109
MED
GAS
BE-108
FLAM
STOR
BE-107
HAC
BC-100
STORAGE
BC-103ASTORAGE
EQUIPMENT/TOILET
BC-105
WHCH TOILET
BC-104ARM AND LEG WHRLP
BC-107
EQUIP
WASHBD-106
F. TLT
BD-102A
F. SHWR/
LKR
BD-102
TLT
BC-110
EQUIP / STRET STORAGE
WHCH TOILET
BC-118
WHCH
TLT MALE
BC-117B
TELE.
BC-114
WOMENS
TOILET
BC-122B
TLT
BC-123C MENS
TLT
BC-122C
EQUIP.
STORAGEBC-123A
HAC
BC-127C
SOIL
UTILITYBC-127
M. TLT
BD-115A
FEMALE
TOILET
BD-116A
CART
DRY
BD-117A
HAC
BD-112
EQUIP GAS
CYLINDER STORAGE
BD-110
WOMENS
LOCKERBD-116
PASSAGE WAY
CB-33
TOILET
BD-107A
STERILE PREPARATION RM
BD-103A
SECY /
WAITING
BB-155
MULTI-
PURPOSE
MULTI-
PURPOSE
NURSE STATION
CB-48
PT
DRESSINGBC-103
EQUIPMENT
STORAGE
BC-107A
CLEAN
UTILITY
BD-101
RECEPT / PHARM
BF-105
CORRIDOR
CB-29B
CB-29C
PRIMARY CARE
NURSE
BG-124
WAITING
BC-122
WAITING RM
CB-12
D-2
EQUIPMENT
STORAGE
BC-102
LINEN
BC-129
OXYGEN
STORAGE
BC-138
IV ADMIXTURE
CORR.
CB-24
OCCUPATIONAL THERAPY
BC-116
CASH CART
BB-146
TUMOR
REG.
BB-147
EXAM /
TREATMENT
BB-150
CORR.
CB-53
CORR.
CB-29A
BC-125D
CORR.
CB-42
CORR.
CB-41
WAITING RM
CB-8
RECEPTION
CB-8A
WAITING RM
CB-9WAITING
CB-10
CONSULT RM
BF-101
CONSULT RM
BF-102
CONSULT RM
BF-103
TRAINING
RM
SECY
BB-154
POD
EXAM
BG-109
EXAM
BG-100
POD
EXAM
BG-105
POD
EXAM
BG-107
AUTOPSY RM
BE-112
MORT REFRIG
MORGUE
BE-113
CORR.
CB-38
EXAM
BC-126J
EXAM
BC-126I
EXAM
BC-126H
EXAM
BC-126G
EXAM
BC-126F
EXAM /
TREAT
BC-126E
CORRIDOR
CB-19
OFFICE
BB-141
EXAM
BB-133
BA-102D
SVC BAY
BF-118
CONCOURSE
CB-6
WAITING RM
CB-7
WAITING RM
CB-14
CORRIDOR
CB-15
CORR.
CB-16
EXAM /
TRTMNT
BB-107
CORRIDOR
CB-17
NURSE
STATION
CB-18
TOILET MALE
BB-100
WOMENS
TOILET
BB-101
EXAM /
TREATMENT
BB-112
OFFICE
BB-115EXAM
BB-116
IT
SPECIALIST
OFFICEBB-114
OFFICE
BB-113
ELEC.
BB-102
SVC BAY
BB-165
DIABETIC
CLASS RM
BB-104
SVC BAY
BB-137 STAIR
RECEPTION
CB-13A
CORR.
CB-22
STAIR
NO-5
CORR.
CB-28
LOBBY
CB-5
OFFICE
BA-105
OFFICE
BA-102C
AGENT
CASHIER
BA-104
OFFICE
BA-103
WOMENS
TOILETBA-100
MENS
TOILETBA-101
AGENT
CASHIER
BA-104B OFFIC OFFICE OFFICE
IDRM OFFICE
BA-106D
CAFE
BA-102
BA-102A
BA-102B
OFFICE
BA-101B
STORAGE
BE-103
DECONTAM RM
BD-103
AITO
CART
WASH
BD-104
CLEAN SUPPLY
BD-117
CORR.
CB-30
CLEAN SUPPLY
BD-117B
SVC BAY
BD-118
GENERAL
STORAGE
PAP AND EMP
CLOTHING
BE-100A
ELECTRICAL
BE-101
ELECTRICAL
BE-102
EMS
BE-117
HAC
BE-115
CORR.
CB-37
GROSS
SPEC
STORE
BE-118
CORR.
CB-45
TELE.
BG-138
CONCOURSE
CB-15
EXAM
BB-153
OFFICE
BB-122
EXAM /
TREATMENT
BB-123
EXAM /
TREATMENT
BB-125
CORRIDOR
CB-20
OFFICE
SOCIAL
WORKERBB-129
EXAM /
TREATMENT
BB-145
CORR.
CB-21
PHARMACY
BF-110
SVC BAY
BF-116
VAULT STORAGE /
DISPENSE
BF-109
OFFICE
CHIEF
RMS
BB-157
CLINICAL
DIETITIAN OFFICE
OFFICE
ASST CHIEF
BB-152
CHIEF
BB-149
MEN TOILET
BB-155
PHYS THERAPY
BC-101
TREATMENT
BC-101A
WORK AREA / OFFICE
BC-109
OFFICE /
WORK AREA
BC-106
STAIR
NO-1
PHARMACY STORAGE
BE-104
OFFICE
BE-105
BE-106
STAFF
TOILET
BE-111
OFFICE
BE-110
TELE
BE-100
ELEC
BD-100
CLEAN SUPPLY
BD-117C
OPEN OUTSIDE
AREA WAY
TRANSFORMER
RM 4
BG-121
SWITCH
BOARD
BG-121A
TELE /
SIGNAL
BG-120
SVC BAY
BG-119
CORRIDOR
CB-44CRAWL SPACESTAIR
NO-3
SWITCH
BOARD RM
BF-117ATRANSFORMER RM
BF-117
LOBBY
CB-39
VESTIBULE
CB-40
STAIR
NO-2
ELEVATOR
ELEVATOR
S-4
CHIEF
OFFICE
BF-108
SUPER
PHARM
BF-106C
DRUG INFO
SVC
BF-106
CLERICAL OFFICE /
WORK AREA
BF-106B
CHIEF
CONFERENCE
RMBF-107
SECY / WAITING
BF-106A
LOBBY
CB-11
ELEVATOR
P-3
LOUNGE
BG-117
EXAM/
TREATMENT
BG-123
OFFICE
BG-125
EXAM
BG-116
EXAM/
TREATMENT
BG-127
EXAM/
TREATMENT
BG-114
OFFICEBG-112
EXAM/OFFICE
BG-128
DIRTY
UTILITY
BG-129
GENERAL
STORAGE
BG-111
BREAK RM
BF-110D EXAM
RM
BG-115D
EXAM
RM
BG-115C
EXAM
RM
BG-115B
EXAM
RM
BG-115E
EXAM
RM
BG-115F OFFICE
BG-115G
OFFICE
BG 113
ELECTRICAL
BG-103
OFFICE
BG-104
OFFICE
BG-110
CORR.
CB-43
HAC
BG-
EXAM
RM
BG-126A
CORRIDOR
BG-126
OFFICE/EXAM
RMBG-126D
CORR.
CB-46
EXAM
RM
BG 126B
EXAM/OXYGEN
STORAGE
BG-126C
OFFICE
BG-131
OFFICE
BG-132
ELEC.
BG-139
OFFICE
BG-137
EXAM
BG-135
EXAM
BG-134
CORRIDOR
CB-47
EXAM /
TREATMENT
BG-108
EXAM /
TREATMENT
BG-136
EXAM
BG-133
EXAM
BG-106
CORR.
CB-49
OFFICE
BG-101
OFFICE
BG-102
CORRIDOR
CB-50
CORR.
CB-51
OFFICE
BF-110C
IV ADMIXTURE STORAGE AREA
BF-110B
CLEAN LINEN STORE
BC-131
KEMO RM
BF-111A
IV ADMIXTURE
BF-111
ELEVATOR
S-1
ELEVATOR
S-2
ELEVATOR
S-3
S ELEVATOR LOBBY
CB-36
CORR.
CB-32
HALLWAY
CB-34
ELEVATOR / MACH
BD-109
MALE SHOWER
BD-107
HACBD-105
OFFICE
BD-111
STAIR
NO-8
CORRIDOR
CB-31
ELECTRICAL
BD-122A
TRANSFORMER
RM 2
BD-122
SVC BAY
MECH
STORAGE
BD-123A
SVC BAY
BD-123
ENG CONTR CENTER
BD-124
STAIR
NO-7
CORR.
CB-35
CORR.
CB-27
CHIEF
BD-114C
CORRECT KINESLO
THERAPY
BC-113
EQUIPMENT
STORAGE
BC-111
BC-112
THERAPY
WAITING RM
BC-115
OFFICE
BC-117A
KITCHEN
BC-117
BC-121
SPLINTING
BC-120
EQUIP
STORE
BC-119
M.
LKRS
BD-115
CLER
BD-114
ASST CHIEF
BD-114B
OFFICE
BD-108
LOUNGE
BD-113
CL-2
COMPUTER
BD-114A
EXAM /
TREATMENT
BB-109
EXAM /
TRTMNT
BB-105
EXAM /
TREATMENT
BB-136
EXAM /
TREATMENT
BB-106
OFFICE
BB-108
EXAM
BB-134
CLEAN
UTILITY
BB-117
DIRTY
UTILITY
BB-128
EXAM /
TREATMENT
BB-119
EXAM /
TREATMENT
BB-126
EXAM /
TREATMENT
BB-110
EXAM /
TREATMENT
BB-132
EXAM /
TREATMENT
BB-111
EXAM /
TREATMENT
BB-130
EXAM /
TREATMENT
BB-120
EXAM /
TREATMENT
BB-124
EXAM /
TREATMENT
BB-151
EXAM /
TREATMENT
BB-127
EXAM /
TRTMNT
BB-148
EXAM /
TREATMENT
BB-143
EXAM /
TREATMENT
BB-131
EXAM
BB-135
EXAM /
TREATMENT
BB-139
OFFICE
CLINICAL
DIETITIAN
BB-163
ELEC.
BB-161
OFFICE
SPEECH
PATHOLOGYBB-160
OFFICE RMS
COORD.
BB-159
OFFICE
PATIENT
HEAD
BB-158
CORR.
CB-23
HOUSE
KEEPING
COPY
RM
BB-142
LOUNGE
BB-138
OFFICE
SPEECH
PATHOLOGY
BB-164
CLEAN
LINEN
BC-127B
CLN
SUPP
BC-127A
STR
NO-4
MEDS
BC-123B
EDUCATION
OFFICE
BC-123
LOUNGE
BC-124
NURSE
STATION
BC-126
NURSE
STATION
BC-125
EXAM
BC-125K
EXAM
BC-125J
EXAM
BC-125IEXAM
BC-125E
EXAM
RM
BC-125F
EXAM
BC-125G
EXAM/
OFFICEBC-125H
EXAM
BC-125C
EXAM
BC-125B
EXAM
BC-125A
OFFICE
BC-126D
EXAM
BC-126C
EXAM
BC-126B
EXAM
BC-126A
RECEPTION
BC-122A
ELEVATOR
P-1
ELEVATOR
P-2
WAITING RM
CB-13
OFFICE
MULTI-
PURPOSE
BB-103
SHAFT
ELEVATOR
CORR.
SHAFT
SHAFT
TOILET
TOILET
CORRIDOR
ELEVATOR
CORR.
ELECTRICAL
BC-108
A&MM WAREHOUSE
A&MM WAREHOUSE
MAIL ROOM
A&MM WAREHOUSE
A&MM WAREHOUSE
A&MM WAREHOUSE
SPD SPD
SPD
SPD
MECH
BE-103A
SPD
SCOPE
PROCESSING
BREAKDOWN ROOM
BE-103B
A&MM WAREHOUSE
BD-103C
OFFICE
BD-117C
A&MM WAREHOUSE
SPD
SCOPE
PROCESSING
BD-103B
CB-29
BB-118
BB-144
BB-156
EXIT
EXIT
EXIT
EXIT
EXIT
OFFICE
BE-105A
GENERAL
STORAGE
TOILET TOILET
LOCKERS
OFFICE
OFFICE
TEMP
STORAGE
FOR
RETURNED
MEDS.
IV ADMIXTURE
LAB
EXAM /
TREATMENT
EXAM /
TREATMENT
EXAM
BC-116A
BC-116B
BA-106E
BA-106C
CB-
45C
OFF.
CB-
45B
OFF.
CB-
45A
OFF.
OFFICE
BA-106BBA-106A
EXIT
CORRIDOR
OFFICE
OFFICE
BF-110D
BF-110E
A&MM WAREHOUSE
MAIL ROOM
RV
RV
RV
FE
N #83
'BLD 143' -
BF-138
'BLD 143' -
BG-138
RP
#85
N #84
'BLD 143' -
BG-138
N
#87'BLD 143' -
BC-114
N #90
'BLD 143' -
BC-114
FE
N
#88 'BLD 143' -
BE-100
N #89
'BLD 143'
- BE-100
RP
#86
'BLD 143'
- BG-138
S S S S S S
S
S S S S S
S
S S S S S S S
S S
S S
S S
S S
S S
S S
S S
S S
SSSSS
S
S
SSSSSS
S
SSSSS
S
S
S S S S
S
S S
S S
S
S S S S S
S
S S S S S
S S
S S
S
S S
S S S S S S S
S S
S S
S S
S S
S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S
S S S S S
S
EXISTING PANEL -
PANEL - 'BEELD'
S S
S S
S S
S S
SSSSSSS
TELE
BG-138
'143-BEELD'
- 12
TELE
BC-114
'143-BEELD'
- 14
TELE
BE-100
'143-BEELD'
- 16
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
321 4 5 6 7
A B
C E
Dwg. of
LocationLocation
Office of Construction and Facilities Management
PROJECT MANAGER: ACG Project Number
Revisions: Date
CONSULTANTS:
OCTOBER 24, 2022 ADRKTK
658-20-10520-210
CONSTRUCTION DOCUMENTS - FOR CONSTRUCTION
FULLY SPRINKLERED
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A. 34Engineers Architects
U.S. Department of Veterans Affairs
FACILITY WIDE SECURITY
CAMERAS UPGRADE
SALEM VA MEDICAL CENTER
1970 ROANOKE BLVD.
SALEM, VA 24153
CAMERA SYMBOL LEGENDCAMERA SYMBOL LEGEND
SYMBOL HEIGHT DESCRIPTION
CCTV FISH EYE
(WP-WEATHER PROOF)
TYPE
12 MP
H4F-DO1-IR
5 MP H5A
24 MP
24C-H4A-3MH
CCTV FIXED DOME
(WP-WEATHER PROOF)
6 MP H5A
360 32 MP
32C-H4A-4MH
3 MP
H4 LPC
FE
MANUFACTURER
AVIGILON
TOTAL
DEVICES
AVIGILON
AVIGILON
AVIGILON
AVIGILON
AVIGILON
AVIGILON
CCTV FIXED DOME
(WP-WEATHER PROOF)
CCTV MULTISENSOR
(WP-WEATHER PROOF)
CCTV MULTISENSOR
(WP-WEATHER PROOF)
CCTV MULTISENSOR
(WP-WEATHER PROOF)
CCTV MULTISENSOR
(WP-WEATHER PROOF)
CCTV LICENSE PLATE
(WP-WEATHER PROOF)
24 MP
24C-H4A-3MH
24 MP
24C-H4A-3MH
D6
360L
CAMERA ABBREVIATIONS
N
RP
RV
WP
PROVIDE AND INSTALL NEW CAMERA
REPLACE EXISTING CAMERA WITH NEW CAMERA
REMOVE EXISTING CAMERA
WEATHER PROOF
SPECIAL NOTE
ALL CAMERAS LOCATED ON THE EXTERIOR OF THE
BUILDING ARE SHOWN ON SHEET TS101 UNLESS
NOTED OTHERWISE.
WALL RATINGS LEGEND:
SMOKE WALLS S S S
1 HOUR FIRE WALL
S
2 HOUR FIRE WALL
3 HOUR FIRE WALL
D5
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
AVIGILON
143TK101
2 BUILDING 143 BASEMENT FLOOR SECURITY PLAN
1/16" = 1'-0"
0 8 16 320
NORTH
SHEET NOTES:
1. REMOVE EXISTING CAMERA AND CABLING BACK
TO SOURCE.
2. INSTALL NEW CAMERA. PROVIDE AND INSTALL
NEW 4 PR UTP CABLING TO NEW PoE MID-SPAN
DEVICE IN IT ROOM BG-138. REPAIR/REPLACE
SURFACES AFFECTED BY CAMERA EQUIPMENT
INSTALLATION TO MATCH SIMILAR/EXISTING
CONDITIONS.
3. INSTALL NEW CAMERA. PROVIDE AND INSTALL
NEW 4 PR UTP CABLING TO NEW PoE MID-SPAN
DEVICE IN IT ROOM BC-114. REPAIR/REPLACE
SURFACES AFFECTED BY CAMERA EQUIPMENT
INSTALLATION TO MATCH SIMILAR/EXISTING
CONDITIONS.
4. INSTALL NEW CAMERA. PROVIDE AND INSTALL
NEW 4 PR UTP CABLING TO NEW PoE MID-SPAN
DEVICE IN IT ROOM BE-100. REPAIR/REPLACE
SURFACES AFFECTED BY CAMERA EQUIPMENT
INSTALLATION TO MATCH SIMILAR/EXISTING
CONDITIONS.
5. REMOVE EXISTING CAMERA. REMOVE
ASSOCIATED EXISTING LOW-VOLTAGE WIRING
BACK TO SOURCE. REPAIR/REPLACE SURFACES
AFFECTED BY REMOVAL OF CAMERA EQUIPMENT
TO MATCH SIMILAR EXISTING CONDITIONS.
6. PROPOSED LOCATION FOR NEW PoE MID-SPAN
DEVICE MOUNTED IN EXISTING, WALL MOUNTED
DATA RACK (COORDINATE LOCATION WITH COR
AND OIT REPARESENTATIVE). PROVIDE NEW,
FLOOR MOUNTED UPS CLOSE ENOUGH FOR PoE
MID-SPAN DEVICE TO PLUG INTO UPS.
COORDINATE WITH PoE MID-SPAN DEVICE
MANUFACTURER FOR POWER CORD LENGTH.
REFERENCE 2/T-602 FOR MORE INFORMATION.
7. PROVIDE POWER OUTLET FOR NEW CCTV
EQUIPMENT. INSTALL POWER OUTLET WITHIN 5
FEET OF NEW UPS LOCATION. SIZE CONDUIT AND
CONDUCTORS PER THE LATEST EDITION OF THE
NEC.
8. EXISTING WALL MOUNTED SWITCHES AND PATCH
PANELS.
9. PROPOSED LOCATION FOR NEW PoE MID-SPAN
DEVICE AND NEW WALL MOUNTED SHELF
(COORDINATE LOCATION WITH COR AND OIT
REPRESENTATIVE). PROVIDE NEW, FLOOR
MOUNTED UPS CLOSE ENOUGH FOR PoE
MID-SPAN DEVICE TO PLUG INTO UPS.
COORDINATE WITH PoE MID-SPAN DEVICE
MANUFACTURER FOR POWER CORD LENGTH.
REFERENCE 2/T-601 FOR MORE INFORMATION.
10. PROVIDE 3 NEW 1P, 20A CIRCUIT BREAKER IN
EXISTING PANEL FOR NEW RECEPTACLE IN IT
ROOMS BG-138, BC-114, AND BE-100.
11. EXISTING VSS MONITOR AND PC TO REMAIN.
REWORK SO EXISTING MONITORING CAPABILITIES
AT THIS LOCATION ARE RE-ESTABLISHED AFTER
WORK IS COMPLETE. COORDINATE ANY
DOWNTIME WITH PHARMACY STAFF.
12. REMOVE EXISTING CAMERA FIELD DISTRIBUTION
BOX AND ENCODER. SURRENDER EQUIPMENT TO
THE POLICE.
13. PROVIDE NEW 4", UL LISTED SLEEVE.
0 2 4 8
NORTH
1 1/4" = 1'-0"
TELECOM ROOM ENLARGEMENTS
143TK101
A. HOME RUN FROM CAMERAS INDICATES THE
TELECOMMUNICATIONS ROOM TO BE USED FOR
NEW CABLING TERMINATIONS ON EXISTING
PATCH PANELS.
B. CCTV SERVICES ARE TO REMAIN ACTIVE
OUTSIDE AREAS UNDER ACTIVE CONSTRUCTION
AT ALL TIMES. FIELD VERIFY CIRCUITS SHOWN
AND RETAIN SERVICES TO ALL DEVICES AND/OR
SYSTEMS DURING DEMOLITION AND REMODEL
OF THE RESPECTIVE AREAS.
C. ALL EXISTING CONDITIONS AND DEVICES ARE
BASED ON THE BEST AVAILABLE INFORMATION
AT THE TIME OF SURVEY AND VISUAL
INSPECTION. VERIFY EXISTING CONDITIONS IN
FIELD.
D. REMOVE ALL UNUSED CONDUIT AND CABLING.
E. INSTALL CONDUCTORS AND CONDUITS
CONCEALED IN NEW WALLS AND PROVIDE A NEW
FACEPLATE.
F. ALL NEW RECEPTACLES SHALL BE LABELED
WITH THEIR SOURCE PANEL AND CIRCUIT
NUMBER.
G. NEW CCTV CABLING TO BE RUN ON J-HOOKS 2'
OC ABOVE CEILING IN CORRIDORS.
H. ALL CONDUIT SECURITY JUNCTION BOXES AND
RACEWAY PROVIDED BY ELECTRICAL
CONTRACTOR UNO. ALL CONDUIT SHALL BE 3/4"
MINIMUM. ELECTRICAL CONTRACTOR TO SIZE
CONDUIT PER THE MOST CURRENT EDITION OF
THE NEC.
I. ALL DEMOLISHED CAMERAS AND ASSOCIATED
EQUIPMENT SHALL BE TURNED OVER TO THE
POLICE DEPARTMENT. COORDINATE WITH COR.
J. COORDINATE EXACT LOCATION OF ALL CAMERAS
DESIGNATED TO BE REMOVED PRIOR TO ANY
WORK BEING DONE.
K. CONTRACTOR TO REPLACE DAMAGED CEILING
TILE AND GRID ASSOCIATED WITH WORK AT NO
ADDITIONAL COST TO THE GOVERNMENT.
L. COORDINATE AND CONFIRM ALL CABLE ROUTING
WITH COR PRIOR TO ROUGH-IN.
BUILDING 143 BASEMENT FLOOR
SECURITY PLAN AND TELECOM ROOM
ENLARGEMENTS
SHEET KEY NOTES:X
143TK101
143TK101
DocuSign Envelope ID: 3ADC3376-EFA9-4753-9EE8-D15D0B94D50D
UNISEX
TOILET
VEST
101A
CORR
ELEC
ROOM
PAT.
ROOM
TOILET
166A
TOILET
167A
TOILET
165A
PAT.
ROOM
PAT.
ROOM
TOILET
164A
TOILET
163A
PAT.
ROOM
PAT.
ROOM
TOILET
162A
TOILET
161A
PAT.
ROOM
PAT.
ROOM
TOILET
160A
PAT.
ROOM
TOILET
159A
GROUP
GROUP
TOILET
157AEMER
EXIT
DINING
DAYROOM
PAT.
ROOM
154TOILET
154A
PAT.
ROOM
TOILET
153A
PAT.
ROOM
TOILET
152A
TOILET
151A
PAT.
ROOM
PAT.
ROOM
TOILET
139A
ELEC
LAUNDRY
DAYROOM/DINING
MEDS
WORK
PAT.
ROOM
TOILET
138A
TOILET
137A
PAT.
ROOM
TOILET
136A
PAT.
ROOM
136EXAM
TOILET
135A
DAYROOM/DINING
STOR
TOILET
131A
GROUP
TOILET
130A
PAT.
ROOM
PAT.
ROOM
TOILET
129A
PAT.
ROOM
TOILET
128A
TOILET
127A
PAT.
ROOM
PAT.
ROOM
TOILET
126A
CORR
PAT.
ROOM
TOILET
124A
TOILET
123A
PAT.
ROOM
PAT.
ROOM
TOILET
122A TOILET
121A
PAT.
ROOM
EXAM
TOILET
120A
LAUNDRY
DATA/
ELEC
117 ELEC
117A
STAFF
TOILET
WATER SERVICE
STAFF
TOILET
STAFF
SECL
TOILET
SECL
NURSE
WORK
CORR
CORR
CORR
NOURISH/
RE-THERM
EQUIPMENT
STORAGE
LINEN
QUIET
EXAM
TDO
PROCS
VISITOR
ROOM
CORR
WAITING
NURSE
INTERVIEW
DINING
DAYROOM
TEAM
ROOM
CORR
CORR
CORR
CORRIDOR
WOMEN'S UNIT
GENERAL UNIT
GERO UNIT
ACUTE UNIT
WORK
156A
NURSE
WORK
NURSE
WORK
D6
RP
#109
WP
D6
RP
#91
1 2
1 2 1 2
D6 N #92
D6
RP
#93
N #94
N #103
N #104
D6 N
#102
N
#95
D6
RP
#96
N #101
N #105
D6
RP
#106
WP
D6
RP
#107
D6
RP
#108
N #100
FE
N #99
N #110
D6
RP
#97
N #111
N #98
N #112
D6
RP
#113
WP
N #114
D6
RP
#115
N #116
N #118
N #119
RP
#117
WP
RV
'BLD 170'
-117
'BLD 170'
-117
'BLD 170'
-117
'BLD 170'
-117
'BLD 170'
-117
'BLD 170'
-117 'BLD 170'
-117
'BLD 170'
-117
'BLD 170'
-117
'BLD 170'
-117
'BLD 170'
-117
'BLD 170'
-117
'BLD 170'
-117
'BLD 170'
-117
'BLD 170'
-117
'BLD 170'
-117
'BLD 170'
-117
'BLD 170'
-117
'BLD 170'
-117
'BLD 170'
-117
'BLD 170'
-117
'BLD 170'
-117
'BLD 170'
-117
'BLD 170'
-117
'BLD 170'
-117
'BLD 170'
-117
'BLD 170'
-117
'BLD 170'
-117
'BLD 170'
-117
S S
S S
S S
S S
S S
S
SSS
S
S S
S S
S S
S S
S S
S S S S S S S
S S
S S
S
SSSSSSS
SS
S
S
S S S
S
S S S S S S
S
SSSSS
S
S S S S S S S
S S
S S
S S
S S
S
S S S
S S S S S S S S
S S
S S
S S
S S
S
S S S S S S S S S S S S S S S
S
S S S
S S
S S S S S S S S S S S S S S S
S S
S
S S
SSSS
SS
S
SSSSSS
S
S S
S S
S S
S S
S S S S S S S S S S
S
S
S S
SSSS
S S
S S S
S S
SS
S
S
SSSSSSSSS
S
S
S S
S S
SSSSS
S
S S S S S S
S S
S S
S S
S S S
SS
S
S S
S S
S S
S S
S S
S S
S S
SS
S S S
S S
S S
S S
5 5
EXISTING
PANEL -
PANEL 'EQ2'
'EC2' - 34
EXISTING
PANEL -
PANEL 'EC2'
EXISTING
PANEL -
PANEL 'LS2'12
'EC2' - 36
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
321 4 5 6 7
A B
C E
Dwg. of
LocationLocation
Office of Construction and Facilities Management
PROJECT MANAGER: ACG Project Number
Revisions: Date
CONSULTANTS:
OCTOBER 24, 2022 ADRKTK
658-20-10520-210
CONSTRUCTION DOCUMENTS - FOR CONSTRUCTION
FULLY SPRINKLERED
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A. 34Engineers Architects
U.S. Department of Veterans Affairs
FACILITY WIDE SECURITY
CAMERAS UPGRADE
SALEM VA MEDICAL CENTER
1970 ROANOKE BLVD.
SALEM, VA 24153
CAMERA SYMBOL LEGENDCAMERA SYMBOL LEGEND
SYMBOL HEIGHT DESCRIPTION
CCTV FISH EYE
(WP-WEATHER PROOF)
TYPE
12 MP
H4F-DO1-IR
5 MP H5A
24 MP
24C-H4A-3MH
CCTV FIXED DOME
(WP-WEATHER PROOF)
6 MP H5A
360 32 MP
32C-H4A-4MH
3 MP
H4 LPC
FE
MANUFACTURER
AVIGILON
TOTAL
DEVICES
AVIGILON
AVIGILON
AVIGILON
AVIGILON
AVIGILON
AVIGILON
CCTV FIXED DOME
(WP-WEATHER PROOF)
CCTV MULTISENSOR
(WP-WEATHER PROOF)
CCTV MULTISENSOR
(WP-WEATHER PROOF)
CCTV MULTISENSOR
(WP-WEATHER PROOF)
CCTV MULTISENSOR
(WP-WEATHER PROOF)
CCTV LICENSE PLATE
(WP-WEATHER PROOF)
24 MP
24C-H4A-3MH
24 MP
24C-H4A-3MH
D6
360L
CAMERA ABBREVIATIONS
N
RP
RV
WP
PROVIDE AND INSTALL NEW CAMERA
REPLACE EXISTING CAMERA WITH NEW CAMERA
REMOVE EXISTING CAMERA
WEATHER PROOF
SPECIAL NOTE
ALL CAMERAS LOCATED ON THE EXTERIOR OF THE
BUILDING ARE SHOWN ON SHEET TS101 UNLESS
NOTED OTHERWISE.
WALL RATINGS LEGEND:
SMOKE WALLS S S S
1 HOUR FIRE WALL
S
2 HOUR FIRE WALL
3 HOUR FIRE WALL
D5
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
CEILING
MOUNTED
AVIGILON
170TK101
BUILDING 170 BASEMENT FLOOR
SECURITY PLAN
1 BUILDING 170 BASEMENT FLOOR SECURITY PLAN
1/8" = 1'-0"
00 4 8 16
NORTH
1. REMOVE EXISTING CAMERA AND CABLING BACK
TO SOURCE.
2. INSTALL NEW CAMERA. PROVIDE AND INSTALL
NEW 4 PR UTP CABLING TO NEW PoE MID-SPAN
DEVICE IN IT ROOM 117. REPAIR/REPLACE
SURFACES AFFECTED BY CAMERA EQUIPMENT
INSTALLATION TO MATCH SIMILAR/EXISTING
CONDITIONS.
3. REMOVE EXISTING CAMERA. REMOVE
ASSOCIATED EXISTING LOW-VOLTAGE WIRING
BACK TO SOURCE. REPAIR/REPLACE SURFACES
AFFECTED BY REMOVAL OF CAMERA EQUIPMENT
TO MATCH SIMILAR EXISTING CONDITIONS.
4. PROPOSED LOCATION FOR NEW PoE MID-SPAN
DEVICE MOUNTED IN EXISTING DATA RACK
(COORDINATE LOCATION WITH COR AND OIT
REPRESENTATIVE). PROVIDE NEW, FLOOR
MOUNTED UPS CLOSE ENOUGH FOR PoE
MID-SPAN DEVICE TO PLUG INTO UPS.
COORDINATE WITH PoE MID-SPAN DEVICE
MANUFACTURER FOR POWER CORD LENGTH.
REFERENCE 2/T-602 FOR MORE INFORMATION.
5. PROVIDE NEW 4", UL LISTED SLEEVE ASSEMBLY.
6. PROVIDE POWER OUTLET (NEMA L5-30R) FOR NEW
CCTV EQUIPMENT. INSTALL POWER OUTLET
WITHIN 5 FEET OF NEW UPS LOCATION.
7. REMOVE EXISTING CAMERA FIELD DISTRIBUTION
BOX AND ENCODER. SURRENDER EQUIPMENT TO
THE POLICE.
8. MOUNT CAMERA ON COLUMN, AS HIGH AS
POSSIBLE.
9. MOUNT NEW CAMERA IN HIGH IMPACT SECURITY
CASING.
10. MOUNT NEW CAMERA IN EXISTING HIGH IMPACT
SECURITY CASING.
11. PROVIDE NEW POWER OUTLET FOR VSS MONITOR
(VIEWING ONLY). COORDINATE EXACT LOCATION
WITH COR PRIOR TO ROUGH-IN.
12. REPLACE EXISTING, SPARE, 1P, 20A CIRCUIT
BREAKER WITH NEW 1P, 30A CIRCUIT BREAKER.
13. PROPOSED LOCATION FOR NEW PCs TO SERVE
MONITORS AT NURSE WORK STATIONS.
COORDINATE EXACT LOCATION WITH COR AND OIT
REPRESENTATIVE PRIOR TO ROUGH-IN. PROVIDE
NEW TELECOMMUNICATIONS OUTLET TO SERVE
TWO PCs.
14. PROVIDE NEW POWER OUTLETS FOR CCTV PCs.
COORDINATE POWER OUTLET LOCATION WITH
COR AND OIT REPRESENTATIVE PRIOR TO
ROUGH-IN.
SHEET NOTES:
A. HOME RUN FROM CAMERAS INDICATES THE
TELECOMMUNICATIONS ROOM TO BE USED FOR
NEW CABLING TERMINATIONS ON EXISTING
PATCH PANELS.
B. CCTV SERVICES ARE TO REMAIN ACTIVE
OUTSIDE AREAS UNDER ACTIVE CONSTRUCTION
AT ALL TIMES. FIELD VERIFY CIRCUITS SHOWN
AND RETAIN SERVICES TO ALL DEVICES AND/OR
SYSTEMS DURING DEMOLITION AND REMODEL
OF THE RESPECTIVE AREAS.
C. ALL EXISTING CONDITIONS AND DEVICES ARE
BASED ON THE BEST AVAILABLE INFORMATION
AT THE TIME OF SURVEY AND VISUAL
INSPECTION. VERIFY EXISTING CONDITIONS IN
FIELD.
D. REMOVE ALL UNUSED CONDUIT AND CABLING.
E. INSTALL CONDUCTORS AND CONDUITS
CONCEALED IN NEW WALLS AND PROVIDE A NEW
FACEPLATE.
F. ALL NEW RECEPTACLES SHALL BE LABELED
WITH THEIR SOURCE PANEL AND CIRCUIT
NUMBER.
G. NEW CCTV CABLING TO BE RUN ON J-HOOKS 2'
OC ABOVE CEILING IN CORRIDORS.
H. ALL CONDUIT SECURITY JUNCTION BOXES AND
RACEWAY PROVIDED BY ELECTRICAL
CONTRACTOR UNO. ALL CONDUIT SHALL BE 3/4"
MINIMUM. ELECTRICAL CONTRACTOR TO SIZE
CONDUIT PER THE MOST CURRENT EDITION OF
THE NEC.
I. ALL DEMOLISHED CAMERAS AND ASSOCIATED
EQUIPMENT SHALL BE TURNED OVER TO THE
POLICE DEPARTMENT. COORDINATE WITH COR.
J. COORDINATE EXACT LOCATION OF ALL CAMERAS
DESIGNATED TO BE REMOVED PRIOR TO ANY
WORK BEING DONE.
K. CONTRACTOR TO REPLACE DAMAGED CEILING
TILE AND GRID ASSOCIATED WITH WORK AT NO
ADDITIONAL COST TO THE GOVERNMENT.
L. COORDINATE AND CONFIRM ALL CABLE ROUTING
WITH COR PRIOR TO ROUGH-IN.
SHEET KEY NOTES:X
DocuSign Envelope ID: 3ADC3376-EFA9-4753-9EE8-D15D0B94D50D
1. WALL ASSEMBLY - THE 1, 2, 3 OR 4 HR FIRE-RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES:
A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS (MAX 2 HR FIRE RATED ASSEMBLIES) OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER SPACED 16 IN. (406 MM) OC WITH NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN 3-5/8 IN. (92 MM)
WIDE BY 1-3/8 IN. (35 MM) DEEP CHANNELS SPACED MAX 24 IN. (610 MM) OC.
B. GYPSUM BOARD* - NOM 1/2 OR 5/8 IN. (13 OR 16 MM) THICK, 4 FT. (122 CM) WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. MAX DIAM OF
OPENING IS 26 IN. (660 MM).
2. THROUGH PENETRANT - ONE METALLIC PIPE, CONDUIT OR TUBING INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN PIPE, CONDUIT OR TUBING AND PERIPHERY OF OPENING SHALL BE MIN OF 0 IN. (0 MM) (POINT CONTACT) TO MAX 2 IN. (51 MM). PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED:
A. STEEL PIPE - NOM 24 IN. (610 MM) DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE.
B. IRON PIPE - NOM 24 IN. (610 MM) DIAM (OR SMALLER) SERVICE WEIGHT (OR HEAVIER) CAST IRON SOIL PIPE, NOM 12 IN.
(305 MM) DIAM (OR SMALLER) OR CLASS 50 (OR HEAVIER) DUCTILE IRON PRESSURE PIPE.
C. CONDUIT - NOM 6 IN. (152 MM) DIAM (OR SMALLER) STEEL CONDUIT OR NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL
ELECTRICAL METALLIC TUBING
D. COPPER TUBING - NOM 6 IN. (152 MM) DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING E. COPPER PIPE - NOM 6 IN. (152 MM) DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE.
F. THROUGH PENETRATING PRODUCT* - FLEXIBLE METAL PIPING - THE FOLLOWING TYPES OF STEEL FLEXIBLE METAL GAS
PIPING MAY BE USED:
1. NOM 2 IN. (51 MM) DIAM (OR SMALLER) STEEL FLEXIBLE METAL GAS PIPING. PLASTIC COVERING ON PIPING MAY OR MAY
NOT BE REMOVED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY.
OMEGA FLEX INC
2. NOM 1 IN. (25 MM) DIAM (OR SMALLER) STEEL FLEXIBLE METAL GAS PIPING. PLASTIC COVERING ON PIPING MAY OR MAY
NOT BE REMOVED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY.
TITEFLEX CORP
A BUNDY CO
3. NOM 1 IN. (25 MM) DIAM (OR SMALLER) STEEL FLEXIBLE METAL GAS PIPING. PLASTIC COVERING ON PIPING MAY OR MAY
NOT BE REMOVED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY.
WARD MFG INC
3. FILL,VOID OR CAVITY MATERIAL* - CAULK OR SEALANT - MIN 5/8. 1-1/4,1-7/8 AND 2-1/2 IN. (16, 32, 48 AND 64 MM) THICKNESS OF CAULK FOR 1, 2, 3 AND 4 HR RATED ASSEMBLIES, RESPECTIVELY, APPLIED WITHIN ANNULUS, FLUSH WITH BOTH SURFACES OF WALL. MIN 1/4 IN. (6 MM) DIAM BEAD OF CAULK APPLIED TO GYPSUM BOARD/PENETRANT INTERFACE AT POINT CONTACT
LOCATION ON BOTH SIDES OF WALL.
THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN
WHICH IT IS INSTALLED, AS SHOWN IN THE FOLLOWING TABLE.
THE HOURLY T RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE TYPE OR SIZE OF THE PIPE OR CONDUIT AND THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, AS TABULATED BELOW:
+WHEN COPPER PIPE IS USED, T RATING IS 0 HR.
3M COMPANY - CP 25WB+ CAULK OR FB-3000 WT SEALANT,
*BEARING THE UL CLASSIFICATION MARKING
SYSTEM NO.W-L-1001
JUNE 15, 2005
F RATINGS - 1, 2, 3 AND 4 HR (SEE ITEMS 2 AND 3)
T RATINGS - 0, 1, 2, 3, AND 4 HR (SEE ITEM 3)
L RATING AT AMBIENT - LESS THAN 1 CFM/SQ FT
L RATING AT 400 F - LESS THAN 1 CFM/SQ FT
MAX PIPE OR
CONDUIT DIAM
IN. (mm)
1 (25) 1 (25) 4 (102) 6 (152)
12 (305)
F RATING
HR
1 OR 2
3 OR 4
1 OR 2
3 OR 4
1 OR 2
T RATING
HR
0+, 1 OR 2
3 OR 4
SECTION A-A
1B
1A 3A
A
1. FLOOR OR WALL ASSEMBLY - LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF OR 1600-2400 KG/M3) CONCRETE. EXCEPT AS NOTED IN TABLE UNDER ITEM 4, MIN THICKNESS OF SOLID CONCRETE FLOOR OR WALL ASSEMBLY IS 4-1/2 IN. (114 MM). FLOOR MAY ALSO BE CONSTRUCTED OF ANY MIN 6 IN. (152 MM) THICK UL CLASSIFIED HOLLOW CORE PRECAST CONCRETE UNITS* . WHEN FLOOR IS CONSTRUCTED OF HOLLOW CORE PRECAST CONCRETE UNITS, PACKING MATERIAL (ITEM 3) AND CAULK FILL MATERIAL (ITEM 4) TO BE INSTALLED SYMMETRICALLY ON BOTH SIDES OF FLOOR, FLUSH WITH FLOOR SURFACE. WALL ASSEMBLY MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE BLOCKS* . MAX DIAM OF OPENING IS IN SOLID LIGHTWEIGHT OR NORMAL WEIGHT CONCRETE. FLOOR IS 32 IN. (813 MM).
MAX DIAM OF OPENING IN FLOOR CONSTRUCTED OF HOLLOW-CORE PRECAST CONCRETE UNITS IS 7 IN. (178 MM).
SEE CONCRETE BLOCKS (CAZT) AND PRECAST CONCRETE UNITS (CFTV) CATEGORIES IN THE FIRE RESISTANCE DIRECTORY FOR NAMES OF
MANUFACTURERS.
1A. STEEL SLEEVE (OPTIONAL, NOT SHOWN) - MAX 15 IN. (381 MM) ID (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL SLEEVE CAST OR GROUTED INTO FLOOR OR WALL ASSEMBLY. SLEEVE MAY EXTEND A MAX OF 2 IN. (51 MM) ABOVE TOP OF FLOOR OR BEYOND EITHER SURFACE OF WALL. MAX 16 IN. (406 MM) ID (OR SMALLER) MIN 0.028 (0.71 MM) WALL THICKNESS (OR HEAVIER) GALVANIZED STEEL SLEEVE CAST OR GROUTED INTO FLOOR OR WALL ASSEMBLY. SLEEVE MAY EXTEND A MAX OF 1/2 IN. (13 MM) BEYOND EITHER SURFACE OF FLOOR OR
WALL.
2. THROUGH PENETRANTS - ONE METALLIC PIPE, CONDUIT OR TUBING TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. MAX ANNULAR SPACE BETWEEN PIPE, CONDUIT OR TUBING AND EDGE OF THROUGH OPENING OR SLEEVE IS DEPENDENT ON THE PARAMETERS SHOWN IN ITEM 4. MIN ANNULAR SPACE BETWEEN PIPE OR CONDUIT AND EDGE OF THROUGH OPENING IS 0 IN. (0 MM) (POINT CONTACT). PIPE CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY. THE
FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED:
A. STEEL PIPE - NOM 30 IN. (762 MM) DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE.
B. IRON PIPE - NOM 30 IN. (762 MM) DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE.
C. CONDUIT - NOM 6 IN. (152 MM) DIAM (OR SMALLER) RIGID STEEL CONDUIT.
D. CONDUIT - NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING.
E. COPPER - TUBING NOM 6 IN. (152 MM) DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBE.
F. COPPER PIPE - NOM 6 IN. (152 MM) DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE.
3. PACKING MATERIAL - POLYETHYLENE BACKER ROD OR NOM 1 IN. (25 MM) THICKNESS OF TIGHTLY-PACKED MINERAL WOOL BATT OR GLASS FIBER INSULATION FIRMLY PACKED INTO OPENING AS A PERMANENT FORM. PACKING MATERIAL TO BE RECESSED FROM TOP SURFACE OF FLOOR OR FROM BOTH SURFACES OF WALL AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF CAULK FILL MATERIAL (ITEM 4).
4. FILL,VOID OR CAVITY MATERIAL* - CAULK OR SEALANT - APPLIED TO FILL THE ANNULAR SPACE FLUSH WITH TOP SURFACE OF FLOOR. IN WALL ASSEMBLIES, REQUIRED CAULK THICKNESS TO BE INSTALLED SYMMETRICALLY ON BOTH SIDES OF WALL, FLUSH WITH WALL SURFACE.
AT POINT CONTACT LOCATION BETWEEN PENETRANT AND SLEEVE OR BETWEEN PENETRANT AND CONCRETE, A MIN 1/4 IN. (6 MM) DIAM BEAD OF CAULK SHALL BE APPLIED AT TOP SURFACE OF FLOOR AND AT BOTH SURFACES OF WALL. THE HOURLY F RATINGS AND THE MIN REQUIRED CAULK THICKNESSES ARE DEPENDENT UPON A NUMBER OF PARAMETERS, AS SHOWN IN THE FOLLOWING TABLE:
(A)MIN 2 IN. (51 MM) THICKNESS OF MINERAL WOOL BATT INSULATION REQUIRED IN ANNULAR SPACE.
(B)MIN 1 IN. (25 MM) THICKNESS OF MINERAL WOOL BATT INSULATION REQUIRED IN ANNULAR SPACE ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY. MIN 1 IN. (25 MM) THICKNESS OF CAULK TO BE INSTALLED FLUSH WITH EACH SURFACE OF FLOOR OR WALL ASSEMBLY.
3M COMPANY - CP 25WB+ CAULK OR FB-3000 WT SEALANT. (NOTE: W RATING APPLIES ONLY WHEN FB-3000 WT SEALANT IS USED.)
*BEARING THE UL CLASSIFICATION MARKING
MIN FLOOR OR
WALL THKNS IN.
(MM)
2-1/2 (64)
2-1/2 (64)
4-1/2 (114)
NOM PIPE TUBE OR
CONDUIT DIAM IN.
(MM)
1/2-12 (13-305)
1/2-12 (13-305)
1/2-6 (13-152)
MAX
ANNULAR
SPACE IN.
(MM)
1-3/8 (35)
3-1/4 (83)
MIN. CAULK
THKNS IN.
(MM)
1/2 (13)
1 (25)
1/4 (6) (a)
System No. C-AJ-1044 June 15, 2005
F Ratings - 2, 3, and 4 Hr (See Items 2A and 4) T Rating - 0 Hr
L Rating At Ambient - 2 CFM/sq ft L Rating At 400 F - less than 1 CFM/sq ft
W Rating - Class I (See Item 4)
SECTION A-A
A
A
F
RATING
HR
1-3/8 (35)
1/2 (13)
1 (25)
1 (25)
1 (25)
2 (51)
1 (25) (b)1-3/8 (35)
3-1/4 (83)
2 (51)
2 (51)
2 (51)
1-1/4 (32)1/2-12 (13-305)
1/2-12 (13-305)
22-30 (558-762)
1/2-20 (13-508)
1/2-6 (13-152)
1/2-20 (13-508)
4-1/2 (114)
4-1/2 (114)
4-1/2 (114)
4-1/2 (114)
4-1/2 (114)
5-1/2 (140)
1. FLOOR OR WALL ASSEMBLY - MIN 4-1/2 IN. (114 MM) THICK LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF OR 1600-2400 KG/M3) CONCRETE. WALL MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE BLOCKS* . MAX
DIAM OF CIRCULAR THROUGH OPENING IS 32-1/2 IN. (826 MM).
SEE CONCRETE BLOCKS (CAZT) CATEGORY IN THE FIRE RESISTANCE DIRECTORY FOR NAMES OF MANUFACTURERS.
1A. STEEL SLEEVE (OPTIONAL, NOT SHOWN) - NOM 12 IN. (305 MM) DIAM (OR SMALLER) SCHEDULE 40 (OR HEAVIER) STEEL PIPE SLEEVE CAST INTO CONCRETE FLOOR OR WALL. SLEEVE TO BE FLUSH WITH OR PROJECT MAX 2 IN.
(51MM) FROM TOP SURFACE OF FLOOR OR FROM BOTH SURFACES OF WALL.
2. THROUGH PENETRANT - ONE METALLIC PIPE, CONDUIT OR TUBING INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN PIPE, CONDUIT OR TUBING AND PERIPHERY OF OPENING SHALL BE MIN OF 0 IN. (0 MM)(POINT CONTACT) TO MAX 1-3/8 IN. (35 MM). PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF
METALLIC PIPES, CONDUITS OR TUBING MAY BE USED:
A. STEEL PIPE - NOM 30 IN. (762 MM) DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE.
A1. IRON PIPE - NOM 30 IN. (762 MM) DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE.
B. CONDUIT - NOM 6 IN. (152 MM) DIAM (OR SMALLER) RIGID STEEL CONDUIT.
C. CONDUIT - NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING.
3. PACKING MATERIAL - POLYETHYLENE BACKER ROD OR NOM 1 IN. (25 MM) THICKNESS OF TIGHTLY-PACKED CERAMIC (ALUMINA SILICA) FIBER BLANKET, MINERAL WOOL BATT OR GLASS FIBER INSULATION MATERIAL USED AS A PERMANENT FORM. PACKING MATERIAL TO BE RECESSED FROM TOP SURFACE OF FLOOR OR FROM BOTH SURFACES OF SOLID CONCRETE OR CONCRETE BLOCK WALL AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF CAULK FILL MATERIAL (ITEM 4). AS AN ALTERNATE WHEN MAX PIPE SIZE IS 10 IN. (254 MM) DIAM AND WHEN MAX ANNULAR SPACE IS 1 IN. (25 MM), A MIN 1 IN. (25 MM) THICKNESS OF TIGHTLY-PACKED CERAMIC FIBER BLANKET OR MINERAL WOOL BATT PACKING MATERIAL MAY BE RECESSED MIN 1/2 IN. (13 MM) FROM BOTTOM SURFACE OF FLOOR
OR FROM EITHER SIDE OF SOLID CONCRETE WALL.
4. FILL,VOID OR CAVITY MATERIALS* - CAULK OR SEALANT - APPLIED TO FILL THE ANNULAR SPACE TO THE MIN
THICKNESS SHOWN IN THE FOLLOWING TABLE:
(A) BR = POLYETHYLENE BACKER ROD.
CF = CERAMIC FIBER BLANKET.
GF = GLASS FIBER INSULATION.
MW = MINERAL-WOOL BATT.
(B) CAULK INSTALLED FLUSH WITH TOP SURFACE OF FLOOR OR BOTH SURFACES OF WALL.
(C) CAULK INSTALLED FLUSH WITH BOTTOM SURFACE OF FLOOR OR ONE SURFACE OF SOLID (NON- CONCRETE
BLOCK) WALL.
3M COMPANY - CP 25WB+ CAULK OR FB-3000 WT SEALANT.
(NOTE: W RATING APPLIES ONLY WHEN FB-3000 WT SEALANT IS USED.)
*BEARING THE UL CLASSIFICATION MARKING
MAX PIPE DIAM
IN. (MM)
10 (254)
10 (254)
30 (762)
MAX ANNULAR
SPACE IN. (MM)
1 (25)
1 (25)
2-1/2 (64)
PACKING MATL
TYPE (a)
BR, CF, GF OR MW
CF OR MW
BR, CF, GF OR MW
MIN. CAULK THKNS
IN. (MM)
1/2 (13) (b)
1/2 (13) (c)
1 (25) (b)
System No. C-AJ-1001 June 15, 2005 F Rating - 3 Hr T Rating - 0 Hr
W Rating - Class I (See Item 4)
SECTION A-A
4 4 1
A
A
T-501
TECHNOLOGY DETAILS
3 UL PENETRATION DETAIL W-L-1001
No Scale
1 UL PENETRATION DETAIL C-AJ-1001
No Scale
2 UL PENETRATION DETAIL C-AJ-1044
No Scale
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
321 4 5 6 7
A B
C E
Dwg. of
LocationLocation
Office of Construction and Facilities Management
PROJECT MANAGER: ACG Project Number
Revisions: Date
CONSULTANTS:
OCTOBER 24, 2022 ADRKTK
658-20-10520-210
CONSTRUCTION DOCUMENTS - FOR CONSTRUCTION
FULLY SPRINKLERED
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A. 34Engineers Architects
U.S. Department of Veterans Affairs
FACILITY WIDE SECURITY
CAMERAS UPGRADE
SALEM VA MEDICAL CENTER
1970 ROANOKE BLVD.
SALEM, VA 24153
1, 2, 2A, 4, 5, 7, 8, 9, 10, 11, 12, 14,17, 74, 75, 76, 77, 143, 170, PARKING LOTS B, C, F, H, K, N, Q, R, T, V, X, AND VP
DocuSign Envelope ID: 3ADC3376-EFA9-4753-9EE8-D15D0B94D50D
EXISTING CONCRETE POLE BASE
GRADE
REPLACE EXISTING CAMERA WITH NEW CCTV
CAMERA AND MOUNTING BRACKET TO BE
FURNISHED AND INSTALLED BY CCTV INSTALLER.
COORDINATE MOUNTING REQUIREMENTS WITH
CCTV INSTALLER.
CCTV CAMERA CABLING TO BE RUN INSIDE POLE BY
CONTRACTOR. COORDINATE ANY REQUIREMENTS WITH
CCTV INSTALLER. EC TO PROVIDE A PULL WIRE FROM
HANDHOLE TO DRILLED HOLE AT CAMERA LOCATION.
ELECTRICAL CONTRACTOR SHALL FIELD DRILL 1-1/2"
DIAMETER HOLE IN POLE FOR CAMERA CABLING.
COORDINATE EXACT HEIGHT WITH CAMERA MOUNT.
ROUTE FIBER CABLE INSIDE OF EXISTING POLE BASE
AND EXISTING POLE.
INSTALL NEMA 3R ENCLOSURE ONTO EXTERIOR OF
EXISTING LIGHT POLE. SEE DETAIL 6/T-502 FOR MORE
INFORMATION.
EXISTING POLE LIGHT
EXISTING POLE HANDHOLE
EXISTING 120V NON-GFI
POWER. RUN CONCEALED
INSIDE OF LIGHT POLE.
REMOVE EXISTING CABLE FROM CONDUIT BACK TO
SOURCE, THEN INSTALL NEW FIBER IN EXISTING
CONDUIT.
NOTES:
1. CONTRACTOR TO REMOVE EXISTING CAMERA AND EXISTING CABLING SERVING CAMERA AND INSTALL NEW CAMERA/CABLING SO THAT AT NO TIME SHALL SURVEILLANCE BE LOST FOR MORE THAN 4 HOURS. COORDINATE ALL DOWNTIME AND SCHEDULING WITH COR
PRIOR TO ANY WORK BEING DONE.
2. USE EXISTING CABLE AS PULL STRING FOR NEW FIBER CABLE.
TAP/SPLICE EXISTING 120V CIRCUIT TO SUPPLY POWER TO
FIBER TO ETHERNET CONVERTER.
LICENSE PLATE CAMERA
MEDIA
CONVERTER AT
LIGHT POLE
120V POWER SUPPLY
DEPENDANT ON
FIBER AND MODEL
NETWORK SWITCH
OWNER'S NETWORK FIBER
SWITCH
CAT 6A CABLE
CAT 6A CABLE
MEDIA CONVERTER
IN IT ROOM
OR FIBER DIRECTLY
FROM A FIBER SWITCH
FE EF
MULTI-SENSOR CAMERA
120V POWER SUPPLY
PoE MID-SPAN
DEVICE
A.
DETAIL NOTES :
ALL EQUIPMENT AND INSTALLATION SHALL BE APPROVED BY VAMC
IT DEPARTMENT.
(1) 4 PR UTP
DATA
CABLE/JACK
(1) 4 PR UTP
TELEPHONE
CABLE/JACK
1/2" HIGH BLACK LETTERS
ON CLEAR BACKGROUND,
PANDUIT OR EQUAL ON
PERMANENT LABEL,
TYPICAL.
XXX
XXX
B B
T T
BLANK
SINGLE GANG COVER
PLATE WITH 6 OUTLETS
(TYPICAL). LOCATIONS
AS SHOWN ON PLANS
TELE/DATA (TYP.) ( 4)
(1) 4 PR UTP
TELEPHONE
CABLE/JACK
C C
(1) 4 PR UTP
DATA CABLE/JACK
BLANK
FINISHED FLOOR
MOUNTING HEIGHT AS
SHOWN IN DRAWINGS
4-11/16" SQ. BY 2-1/2"
DEEP BOX WITH SINGLE
GANG 5/8" TILE RING.
1-1/4" CONDUIT WITH
COMMUNICATIONS WIRING
WALL
CORRIDORROOM
6" MIN NYLON BUSHING
COORDINATE WITH DUCTWORK
EXTEND CONDUIT TO ABOVE
FINISHED ACCESSABLE
CEILING IN CORRIDOR TO
CABLE TRAY UNLESS NOTED
OTHERWISE.
SUSPENDED LAY-IN
CEILING
A.
B.
C.
D.
E.
F.
G.
DETAIL NOTES:
ALL CONNECTIONS TO THE PBB AND SBB SHALL BE MADE
WITH COMPRESSION STYLE LONG BARREL CONNECTORS
ON THE CONDUCTOR AND 2-LUG BOLTED CONNECTIONS TO
THE GROUNDING BUS BARS. CONNECTIONS TO STEEL
SHALL BE WITH SILICON BRONZE HARDWARE. CONNECTION
TO SLEEVES OR CONDUITS SHALL BE BY AN APPROVED
GROUNDING BUSHING.
LOCATE PBB AND SBB ON THE LEFT OF THE TTB AND 12"
AFF.
ALL CONDUCTORS USED FOR GROUNDING SHALL BE
MARKED AT CONNECTION POINT AND EVERY TWENTY FEET
(20') THEREAFTER WITH A LABEL IDENTIFYING IT AS THE
TELECOMMUNICATIONS GROUNDING BACKBONE (TBB). USE
PANDUIT #LTYK OR APPROVED EQUIVALENT.
REFERENCE SPECIFICATIONS REGARDING PBB.
REFERENCE SPECIFICATIONS REGARDING SBB.
CONTRACTOR SHALL CLEAN THE GROUNDING BUS BAR
AND APPLY ANTI-OXIDANT PRIOR TO FASTENING THE
CONNECTORS TO THE GROUNDING BUS BAR.
ALL COPPER BACKBONE CABLING SHALL MEET THE
REQUIREMENTS OF TIA/EIA 568-C FOR RISER CABLE.
C O
M M
. E Q
U
IP
M
EN
T/ R
AC
KS
M
ET
AL
S
LE
EV
ES
(W
IT
H
IN
C
O M
M . R
M
ST
R
U C
TU
R
AL
S
TE
EL
BA
SK
ET
/C
AB
LE
T R
AY
G R
O U
N D
L O
O P
PRIMARY
PBB
TR-#1
SBB
COMM. EQUIPMENT/RACKS (RBB)
ELECTRICAL PANEL
STRUCTURAL STEEL
CABLE TRAY
TR-#2
SBB
COMM. EQUIPMENT/RACKS (RBB)
ELECTRICAL PANEL
STRUCTURAL STEEL
CABLE TRAY
PROVIDE 6 AWG
CONDUCTOR, EACH RUN
PROVIDE 1/0 AWG CONDUCTOR
TO PBB FOR EACH SBB.
PROVIDE 2/0 AWG
CONDUCTOR TO GROUND
RING FOR ELECTRICAL
SYSTEM
PROVIDE 1/0 AWG
CONDUCTOR TO PBB
FOR EACH TGB
EL
EC
TR
IC
AL
P
AN
EL
LADDER TRAY
LADDER TRAY
ONMICONVERTER
PoE MEDIA
CONVERTER "FE"
WITH TWO - PoE
PORTS. 1 FOR
LICENSE PLATE
CAMERA AND 1 FOR
PoE MID-SPAN
DEVICE. PROVIDE
WITH INCOMING
FIBER PATCH PORTS.
18"W X 18"H X 8" D NEMA 3R
ENCLOSURE WITH HINGED,
LOCKABLE COVER AND
BACKPLANE
QUAD RECEPTACLES
CONDUIT & WIRING FOR 120V
CIRCUIT. CONTRACTOR TO
CONNECT TO POLE LIGHT
120V CIRCUIT.
FE
60 WATT PoE MID-SPAN
DEVICE FOR
MULTI-SENSOR CAMERA
CAT 6A CABLE
CAT 6A CABLE UP
TO NEW CAMERAS
INCOMING FIBER OPTIC
CABLING FROM IT ROOM.
SEE DETAIL 7/T-502 FOR
ADDITIONAL INFORMATION.
10"
4"
1/4"
3/16" DIAMETER, TYP. FOR 6
1/4" DIAMETER, TYP. FOR 12
TMGB & TGB
1 TELECOM ROOM OPPER GOUND BAR, 1/4" x 4" x 10", HOLE CENTERS TO MATCH NEMA DOUBLE
LUG CONFIGURATION.
STANDOFF BRACKET ASSEMBLY WITH INSULATORS, TYP. FOR 2.
LOCK WASHER, TYPICAL FOR 2.
ANCHOR BOLTS, TYPICAL FOR 2.
A CONTINUOUS #1/0 GREEN INSULATED CONDUCTOR SHALL BE RUN
FROM SERVICE GROUND AT TMGB. BOND NCE CABINET WITH #4 GREEN INSULATED
CONDUCTOR.
T-502
TECHNOLOGY DETAILS
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
321 4 5 6 7
A B
C E
Dwg. of
LocationLocation
Office of Construction and Facilities Management
PROJECT MANAGER: ACG Project Number
Revisions: Date
CONSULTANTS:
OCTOBER 24, 2022 ADRKTK
658-20-10520-210
CONSTRUCTION DOCUMENTS - FOR CONSTRUCTION
FULLY SPRINKLERED
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A. 34Engineers Architects
U.S. Department of Veterans Affairs
FACILITY WIDE SECURITY
CAMERAS UPGRADE
SALEM VA MEDICAL CENTER
1970 ROANOKE BLVD.
SALEM, VA 24153
1, 2, 2A, 4, 5, 7, 8, 9, 10, 11, 12, 14,17, 74, 75, 76, 77, 143, 170, PARKING LOTS B, C, F, H, K, N, Q, R, T, V, X, AND VP
5 NEW EXTERIOR CCTV CAMERA MOUNTED ON EXISTING POLE DETAIL
No Scale
7 FIBER TO ETHERNET CONVERSION DETAIL
No Scale
3 TELECOMMUNICATIONS FACEPLATES
No Scale
1 TELECOMMUNICATIONS OUTLET INSTALLATION DETAIL
No Scale
4 TELECOMMUNICATIONS GROUNDING BAR DETAIL
No Scale
6 TYPICAL EXTERIOR FIBER TO ETHERNET ENCLOSURE DETAIL
No Scale
2 TYPICAL SBB WALL MOUNT DETAIL
No Scale
DocuSign Envelope ID: 3ADC3376-EFA9-4753-9EE8-D15D0B94D50D
4" SQ. JUNCTION BOX WITH SINGLE GANG MUD RING (BYEC)
FLAT WALL BRACKET TYPE FOR WALL MOUNTED
APPLICATIONS. UTILIZE CORNER MOUNT BRACKET FOR
CAMERAS LOCATED ON BUILDING CORNERS.
18.24
8.75
1.68
3.64
7.75
11.75
7.00
3.94
11.74
7.75
8.74
1.68
1.68
2.50
3.82
10.23
7.75
11.73
7.75
11.24
4.38
1.73
4" SQ. JUNCTION BOX
WITH SINGLE GANG
MUD RING (BYEC)
333 [13.1]
545 [21.5]
193 [7.6]
264 [10.4]
4" SQ. JUNCTION BOX WITH SINGLE GANG MUD RING (BYEC)
FLAT WALL BRACKET TYPE FOR WALL MOUNTED
APPLICATIONS. UTILIZE CORNER MOUNT BRACKET FOR
CAMERAS LOCATED ON BUILDING CORNERS.
4" SQ. JUNCTION BOX WITH SINGLE
GANG MUD RING (BYEC)
T-503
TECHNOLOGY DETAILS
VA PROJECT NUMBER
Building Number
Drawing Number
Project Title
Date Checked Drawn
Drawing Title
Approved:
VA FORM 08-6231
A
B C
D E
21 4 5 6 7
321 4 5 6 7
A B
C E
Dwg. of
LocationLocation
Office of Construction and Facilities Management
PROJECT MANAGER: ACG Project Number
Revisions: Date
CONSULTANTS:
OCTOBER 24, 2022 ADRKTK
658-20-10520-210
CONSTRUCTION DOCUMENTS - FOR CONSTRUCTION
FULLY SPRINKLERED
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A. 34Engineers Architects
U.S. Department of Veterans Affairs
FACILITY WIDE SECURITY
CAMERAS UPGRADE
SALEM VA MEDICAL CENTER
1970 ROANOKE BLVD.
SALEM, VA 24153
1, 2, 2A, 4, 5, 7, 8, 9, 10, 11, 12,…