This document contains construction drawings and specifications for a roof replacement project at the West Haven Veterans Affairs Medical Center. The project involves replacing the roof on Building 35A and performing work in the morgue of Building 1. Key details include replacing the existing wood deck and installing a new fluid applied fully reinforced aliphatic roofing system. Additional work involves reworking existing expansion joints, curbs, and lightening protection systems. The specifications provide requirements for roof materials, underlayments, flashing details, and other construction elements.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWN BY
CGS
APPROVED
A HALL
DATE
P R
O J E
C T
C a m p b e l l
A v e
A2.1
R o o f
R e p l a c e m e n t s
Roof Work Plan
DRAWING NAME:
DRAWING NUMBER:
& General Notes
P r o j e c t
O w n e r
L O
C A
T I O
N
DRAWING STATUS:
C a m p b e l l
A v e
W e s t
H a v e n
C
T
DATE No. REVISIONS
Issued for Review:
29 MARCH 2021
29 MARCH 2021
V A
C
T
H
E A
L T
H C
A R
E
B
L D
G
A
AutoCAD SHX Text
ROOF TYPE A-WOOD DECK
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text 1/2" FIBERGLASS FACED GYPSUM ROOF BOARD ADHERED TO INSULATION IN (LOW VOC/LOW ODOR) LOW RISE FOAM INSULATION ADHESIVE PER SPECS. (TYP)
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text
CURB MOUNTED UNIT FLASHING DETAIL
AutoCAD SHX Text
AutoCAD SHX Text A2.1
AutoCAD SHX Text GRIND SMOOTH & PRIME STEEL VENT PIPE OR EQUIPMENT PENETRATION WITH ALPHAGUARD MT METAL PRIMER PRIOR TO ALIPHATIC FLASHING INSTALLATION PER SPECIFICATIONS (TYP)
AutoCAD SHX Text FLUID APPLIED REINFORCED ALIPHATIC FLASHING SYSTEM INSTALLED TO 8" IF POSSIBLE. ABOVE ROOF SURFACE OVER PRIMED SUBSTRATE IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)
AutoCAD SHX Text
CONT. SEALANT CORNER BEAD TO MAKE SMOOTH TRANSITION (TYP)
AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOFING SYSTEM INSTALLED OVER CURED BASE PLY IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text
CURB MOUNTED UNIT FLASHING DETAIL
AutoCAD SHX Text
AutoCAD SHX Text A2.1
AutoCAD SHX Text 1/2" TREATED CDX PLYWOOD FASTENED OVER SELF ADHERING WATERPROOFING MEMBRANE ADHERED TO INSIDE FACE OF MASONRY WALL CONSTRUCTION TO REMAIN PER SPECIFICATIONS (TYP)
AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOFING SYSTEM INSTALLED OVER CURED BASE PLY IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)
AutoCAD SHX Text 16 OZ ALUM. COUNTERFLASHING INSTALLED IN EXISTING RAKED-OUT MORTAR JOINT WITH LEAD WEDGES AND SEALANT PER SPECIFICATIONS - SOLDER ALL JOINTS WATERTIGHT (TYP)
AutoCAD SHX Text
WALL COUNTERFLASHING DETAIL
AutoCAD SHX Text
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text A2.1
AutoCAD SHX Text
REFER TO NEW ROOF ASSEMBLY DETAILS FOR NEW ROOF SYSTEM CONSTRUCTION (TYP)
AutoCAD SHX Text NEW TREATED 4X4 P.T. SLEEPERS FOR MOUNTING OF EXISTING EQUIPMENT / PIPE SUPPORT - VERIFY ALL DIMENSIONS/SIZING IN FIELD (TYP.)
AutoCAD SHX Text SECURE EXIST. EQUIPMENT / PIPE SUPPORT TO NEW BLOCKING WITH S.S. GASKETED SCREWS (TYP.)
AutoCAD SHX Text
PROTECTIVE, GRANULE-SURFACE WALKPAD SET IN WHITE MASTIC. (TYP.)
AutoCAD SHX Text
NON-PENETRATING SLEEPER MOUNTED EQUIP./PIPE SUPPORTS
AutoCAD SHX Text
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text A2.1
AutoCAD SHX Text
AutoCAD SHX Text A2.1
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text
PARAPET COPING / FLASHING DETAIL
AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOFING SYSTEM INSTALLED OVER CURED BASE PLY IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)
AutoCAD SHX Text CONTINUOUS FLUSH COPING SYSTEM W/ 24 GA. STEEL KYNAR PRE-FINISHED PITCHED COPING CAP, OR OTHER FM APPROVED / ANSI-SPRI ES-1 TESTED COPING SYSTEM INSTALLED PER MANUFACTURER OVER FULLY ADHERED TPA FLASHING SYSTEM (TYP)
AutoCAD SHX Text SEAL JOINT BETWEEN COPING AND LIMIT OF FLUID APPLIED FLASHING WITH COMPATIBLE URETHANE SEALANT AND BACKER ROD (TYP)
AutoCAD SHX Text FLUID APPLIED REINFORCED ALIPHATIC FLASHING SYSTEM INSTALLED UP FACE OF PARAPET OVER PLY IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)
AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOFING SYSTEM INSTALLED OVER PLY IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)
AutoCAD SHX Text
REFER TO TYPICAL ROOF ASSEMBLY DETAILS FOR ROOF SYSTEM CONSTRUCTION (TYP)
AutoCAD SHX Text BIO BASED - POLYURETHANE TOP COAT (ASTM VALUES) Abrasion Resistance ASTM C501 Accelerated Weathering ASTM G154 Breaking Strength ASTM D751 Crack Spanning ASTM C1305 Dimensional Stability ASTM D1204 Dynamic Puncture Resistance ASTM D5635 Elongation ASTM D412 Flexibility ASTM D522 Fungi Resistance ASTM G21 Indentation Hardness ASTM D2240 Low Temperature Flexibility ASTM D5147 Peak Load ASTM D5147 Permeance ASTM E96 Static Puncture Resistance ASTM D5602 Tear Resistance ASTM D5147 Tensile Strength ASTM D412 Water Absorption ASTM D570 Water Vapor Transmission ASTM E96 Volume Solids ASTM D 2697 Weight Solids ASTM D 1644
AutoCAD SHX Text
REFER TO NEW ROOF ASSEMBLY DETAILS FOR NEW ROOF SYSTEM CONSTRUCTION (TYP)
AutoCAD SHX Text
CONTINUOUS URETHANE SEALANT BETWEEN CAP SHEET & CURB CONSTRUCTION
AutoCAD SHX Text
CONTINUOUS URETHANE SEALANT BETWEEN UNIT AND FLUID APPLIED FLASHING
AutoCAD SHX Text CURB-MOUNTED AND INS. CURB CONSTRUCTION TO REMAIN- SECURE EQUIPMENT WITH STAINLESS-STEEL BOLTS & NEOPRENE WASHERS BY OWNERS DESIGNATED CONTRACTOR (TYP)
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOFING SYSTEM INSTALLED OVER CURED BASE PLY IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)
AutoCAD SHX Text FLUID APPLIED REINFORCED ALIPHATIC FLASHING SYSTEM INSTALLED UP AND OVER PRIMED CDX PLYWOOD (TREATED) SUBSTRATE IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)
AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOFING SYSTEM INSTALLED OVER CURED BASE PLY- EXTEND TO TOP OF WOOD FIBER CANT STRIP (TYP)
AutoCAD SHX Text
ROOF EXPANSION JOINT FLASHING DETAIL
AutoCAD SHX Text
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text A2.1
AutoCAD SHX Text
REFER TO NEW ROOF ASSEMBLY DETAILS FOR NEW ROOF SYSTEM CONSTRUCTION (TYP)
AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOFING SYSTEM INSTALLED OVER CURED BASE PLY IN STRICT ACCORDANCE WITH MFGR'S SPECIFICATIONS (TYP)
AutoCAD SHX Text
CONTINUOUS URETHANE SEALANT
AutoCAD SHX Text
SHEET-METAL SCUPPER SECURED TO WALL AND DECK AND/OR OPTIONAL WOOD BLOCKING
AutoCAD SHX Text
CLEAN TO BRIGHT METAL AND PRIME
AutoCAD SHX Text
LIQUID APPLIED TOP COAT
AutoCAD SHX Text
ROOF MEMBRANE AND FLASHING
AutoCAD SHX Text
BASE FLASHING AT THRU-WALL SCUPPER DETAIL
AutoCAD SHX Text
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text A2.1
AutoCAD SHX Text FLUID APPLIED FULLY REINFORCED ALIPHATIC ROOFING SYSTEM INSTALLED OVER CURED BASE PLY- EXTEND TO TOP OF (TREATED) WOOD FIBER CANT STRIP (TYP)
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
ROOF HATCH & FLASHING DETAIL
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text A2.1
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING ROOF HATCH TO REMAIN
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text NON-PENETRATING LIGHTNING CONDUCTOR CABLE HOLDER - ADHERE TO CLEAN ROOF SURFACE USING POLYROOF MASTIC (TYP.)
AutoCAD SHX Text NON-PENETRATING LIGHTNING CONDUCTOR AIR TERMINAL HOLDER - ADHERE TO CLEAN ROOF SURFACE USING POLYROOF MASTIC PER DETAIL AT RIGHT (TYP.)
AutoCAD SHX Text LIGHTNING CONDUCTOR AIR TERMINAL HOLDER MAY ALSO BE BOLTED TO REAR FACE OF PARAPET WALL - FASTENERS FASTENERS MUST NOT PENETRATE ROOF MEMBRANE BELOW CAP -COORDINATE THIS -COORDINATE THIS INSTALLATION DETAIL CAREFULLY WITH ROOFER DURING WALL CAP INSTALLATION - SET HOLDER IN SEALANT (TYP.)
AutoCAD SHX Text LIGHTNING CONDUCTOR AIR TERMINAL HOLDER MAY ALSO BE BOLTED TO WALL CONSTRUCTION ABOVE ROOF FLASHING HEIGHT - ROOF FLASHING HEIGHT - SET HOLDER IN SEALANT (TYP.)
AutoCAD SHX Text
LIGHTNING PROTECTION TERMINAL/CABLE MOUNTING DETAILS
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text
AutoCAD SHX Text A2.1
AutoCAD SHX Text NOTE:REWORK EXISTING EXPANSION JOINTS *VERIFY CONDITION & INSTALLATION OF EXISTING JOINT (V.I.F.)
AutoCAD SHX Text BIO BASED - POLYURETHANE BASE COAT (ASTM VALUES) Abrasion Resistance ASTM C501 Accelerated Weathering ASTM G154 Breaking Strength ASTM D751 Crack Spanning ASTM C1305 Dimensional Stability ASTM D1204 Dynamic Puncture Resistance ASTM D5635 Elongation ASTM D412 Flexibility ASTM D522 Fungi Resistance ASTM G21 Indentation Hardness ASTM D2240 Low Temperature Flexibility ASTM D5147 Peak Load ASTM D5147 Permeance ASTM E96 Static Puncture Resistance ASTM D5602 Tear Resistance ASTM D5147 Tensile Strength ASTM D412 Water Absorption ASTM D570 Water Vapor Transmission ASTM E96 Volume Solids ASTM D2697 Weight Solids ASTM D1644
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text FLUID APPLIED REINFORCED ALIPHATIC ROOF MEMBRANE SYSTEM OVER PRIMED PLY - TWO COMPONENT (LOW VOC/LOW ODOR), BIO BASED, POLYURETHANE BASE COAT APPLIED @ 3 GAL/SQ. (48 MIL. WET THICKNESS) WITH POLYESTER FABRIC REINFORCING - INSTALL TWO COMPONENT (LOW VOC/LOW ODOR), BIO BASED, POLYURETHANE TOP COAT OVER CURED BASE COAT & REINFORCING @ 2 GAL/SQ. (32 MIL. WET THICKNESS) INSTALLED PER MANUFACTURER'S SPECIFICATIONS (TYP)
AutoCAD SHX Text HIGH STRENGTH MOD. BIT. MEMBRANE WITH A NON-WOVEN FIBERGLASS MAT/FIBERGLASS SCRIM ADHERED WITH TWO PART (LOW VOC/LOW ODOR) URETHANE, BIO-BASED ADHESIVE PER SPECS.
AutoCAD SHX Text
CAP NAIL TRILAMINATE PLY TO TOP OF FLASHING
AutoCAD SHX Text IT IS THE CONTRACTORS RESPONSIBILITY TO RE-CERTIFY ALL LIGHTNING PROTECTION ON ROOF
AutoCAD SHX Text CONT. URETHANE CORNER BEAD TO MAKE SMOOTH TRANSITION AT ALL 90 DEG. INTERSECTIONS (TYP)
AutoCAD SHX Text
MANSARD SHINGLE DETAIL
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text
AutoCAD SHX Text A2.1
AutoCAD SHX Text THE BOTTUM EDGE OF FELT SHOULD BE POSITIONED ABOVE THE BUTT OF THE SHINGLE AT A DISTANCE EQUAL TO TWICE THE WEATHER EXPOSURE
AutoCAD SHX Text
PLYWOOD SHEATHING
AutoCAD SHX Text
SHINGLES SHOULD HANG 1" OVER ROOF EDGE
AutoCAD SHX Text
INSTALL SHINGLES PER MANUFACTURERS SPEC * USE TIMBERLINE SHINGLES OR EQUAL
AutoCAD SHX Text
BACKER ROD 1 TIME OPENING12 TIME OPENING
AutoCAD SHX Text
NOTE:REWORK EXISTING CURBS
AutoCAD SHX Text
REPLACE FASCIA AS NEED (V.I.F.) MATCH EXISTING
AutoCAD SHX Text INSTALL 3' GUTTER BENEATH EACH SCUPPER ROOF OPENING. REFERENCE BUILDING 35 FOR EXAMPLES
AutoCAD SHX Text
UL-67 (NEMO W-6)[225 PSF]
| Sheets and Views |
| A2.1 |