S02 Hirsch Velocity Fast Facts.pdf

PDF 337 KB Posted

Attached to
Z2DA--523A4-CSI-401 Cath Lab Site Prep Federal contract opportunity
Solicitation number
36C24125R0074
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 1

About this file

This document is a Fast Facts technical specification sheet for the Hirsch Velocity Head-End Software, Version 3.1, detailing comprehensive computer hardware and software requirements, components, and features for an access control and security management system. The specification covers computer system requirements (including Windows Server 2003, Windows XP Professional, SQL Server support), minimum hardware specifications (Pentium 4 processor, 2GB RAM, 40GB hard drive), and a wide range of software features including unlimited user capacity, multiple credential support, advanced access control capabilities, and robust security management tools.

The document provides extensive technical details on key system components such as the ScramblePad (with patented scrambling display), MATCH interface capabilities, DIGITRAC controller models, and SCRAMBLENET networking options. The system supports complex access control functionalities like multi-credential authentication, time zone restrictions, passback controls, temporary user management, alarm routing, and integration with various reader types including proximity, smart card, and biometric technologies. The specification emphasizes flexibility, with support for multiple hardware configurations, expansion options, and interoperability features like SDK professional services support with API for users and credentials.

View the file

Other files for this federal contract opportunity

Other files attached to Z2DA--523A4-CSI-401 Cath Lab Site Prep, newest first.
File Type Posted
36C24125R0074 0008.docx DOCX document
WD MA20260001 01022026.pdf PDF
S02 RFP SB Set Aside 36C24125R0074.pdf PDF
36C24125R0074 0007.docx DOCX document
S02 Existing drawings.zip ZIP file
S02 Clarifications Q and A.pdf PDF
36C24125R0074 0006.docx DOCX document
WD MA2025 07182025.pdf PDF
36C24125R0074 0003.pdf PDF
36C24125R0074 0002.docx DOCX document
36C24125R0074 0001.docx DOCX document
S02 Hirsch Velocity Data Sheet.pdf PDF
S02 Specification Sample 523A4-CSI-401 Cath Lab Site Prep.pdf PDF
S02 WRX PCRA Cathlab Site Prep 523A4-CSI-401-Final.pdf PDF
36C24125R0074 Solicitation.docx DOCX document
S02 WD MA20250001 04042025.pdf PDF
S02 SOW 523A4-CSI-401 Cath Lab Site Prep.pdf PDF
S02 Cores.pdf PDF
S02 Building 1 5th Floor Map.pdf PDF
S02 SHPO Notification Guide.pdf PDF
S02 Past Performance Questionnaire.pdf PDF
S02 SSJ 523A4-CSI-401 Cath Lab Site Prep.pdf PDF
S02 Strike.pdf PDF
S02 Levers.pdf PDF
S02 318_R4_West_Roxbury_MA_VA_WiFi_Fin.pdf PDF
S02 Azurion 7 C20 - R3 standard drawing.pdf PDF
S02 General Design Comments.pdf PDF
Show all 27

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FAST FACTS

HEAD-END SOFTWARE

VEL Version 3.1 – Velocity Server +

Unlimited Clients, and Single User Workstation on CD

VELOCITY COMPUTER

REQUIREMENTS

Software WINDOWS Server 2003 (Server) WINDOWS XP Professional and VISTA on

Client and Single User Workstation SQL Server 2005 Express included SQL Server 2005 optional 32 & 64 Bit OS and SQL Support Hardware (Minimum Required) Pentium 4, 2GB RAM + 40MB per active

Client (Server), 2GB RAM (Client and Single User Workstation)

40 GB Hard Drive 15” - 17” Monitor (1024x768 resolution) Mouse & Keyboard DVD Drive (DVD-RW preferred) Ethernet Port 10/100/1000 2 Serial Port (more if required) for controller communications and card enrollment station 1, 2, or 3 Parallel Ports

Page Printer For Reports Line Printer For Real Time Alarms &

Events Badge Printer for Badge Printing

Optional Sound Card and Speakers Camera for Badging Dual Monitor Card, + 2nd Monitor Modem for Dial-Up Controllers and

PCAnywhere Support (Server) High Performance Video Card, 256MB RAM 2nd Network Interface Card Optional, But Recommended

UPS

Tape Backup (Server) w/ software

To ensure long-term compatibility with VELOCITY feature enhancements and future versions of Windows, invest in the most current computer possible.

VELOCITY COMPONENTS

Event Viewer – Routing by Operator Alarm Viewer – Routing by Operator Enrollment Manager

User Management User defined fields with option for

Drop Down lists Single and Batch Badge Printing Badge Print and Issue Control Person Templates and Person

Groups Multi-Person Edit Scanner Support – Business Card, Drivers License, Passport, PIV Reader

Linked Credential Templates Door/Master Door Groups– Global Function Groups Photo ID Badging – 1 and 2 Sided Badge & Graphics Designer Alarm Graphics

User Customizable Dynamic

ICONS

Alarm Priority / Queue Control Zone Area Status Issue Control Commands CCTV Integration Supports Multiple Formats: BMP, JPG, EMF, WMF, DXF (AutoCad) HTML & IP Camera Links

VELOCITY COMPONENTS – cont.

Velocity Learning Center

Multimedia Tutorials On-Line Help Known Issues Manuals

Customization Manager Language Translations Assign audio WAV files to alarm types Define Alarm Priority Levels Define Alarm Type Response

Instructions Point Customization & Escalation

Status Viewer - User Defined Groups Door Status Alarm Input & Mask Status Relay Status

Command Sets - Issue Commands to Controllers Globally Access / Unlock / Relock Doors Mask / UnMask Alarms Change Facility Threat Level

SQL Manager Manual Backups Database Restore

Velocity Scheduling Agent Archive Alarm and Event Logs SQL Database Backups Synchronize Controller Clocks Run Reports Email Reports Run Import/Export Users Run 3rd Party Application Run Command Set Dial-Up Remote Sites

Operators and Roles Rights and Permissions by

Workstation Defined by Role Restrict by Role: Users, Hardware, Graphics, Reports, Command Sets, Credential Templates, and Status Groups

DVR Integration–American Dynamics and Pelco integrated. Others available

Diagnostics Window User Data Import/Export Wizard Email Notification of Alarm Events Serial Port Formatted Output XML Writer Event/Alarm Output MS Message Queue – XML Output Alarm Responses CCTV Interface Context Sensitive Help Reports - Standard and Customizable Who’s Inside Display

VELOCITY FEATURES

Hardware Features CCM – FLASH Downloadable

Controller Firmware, 4,000 base user capacity (expandable, except M1N)

AEB8 (addresses 1-32) – supports up to 32 Expansion inputs per controller

MEB/CB64 & 128 – Combination Code/Buffer Expansion Board – Up to 132K users supported per controller

X-Box & SNIB2– Supports Regional Passback, User Management, and Input/Output linking for all controllers connected to X-Box or SNIB2

VELOCITY FEATURES – cont.

Software Features Standard Windows Interface User-Configurable GUI by Operator Unlimited User Capacity Multiple Function Credentials Multiple Credentials per User 15 Digit PIN numbers 16 Digit Card Codes Global Time Zones and Holidays 366-Day Holiday Schedule, this year and next year. 4 Holiday Schedules per Time Zone

Automatic Daylight Savings Time Adjustment

Restrict Access By: Time of Day; Day of Week; Door; Alarm Condition

Door Groups – Each Reader Address (Entry & Exit) has own Time Zone

Momentary Access By CODE, Card, Dual Technology

Additional User Functions: Unlock / Relock; Alarm Mask / Unmask;

Lock Down / Lock Down Release

Extended Access with Countdown display on ScramblePad

Special Needs Time Extension Card Only At Dual Technology By

Time Zone 2 Person Access - A/B Rule By Door with Executive Override Tag User For Tracking Door Status Monitoring: Door Forced;

Door-Open-Too-Long; Auto-Relock Threat Levels (99) control of reader disable, user restriction, dual required Passback – Direction Control

Hard / Soft Timed Internal Restriction Passback Zones with Executive

Override Regional per X-Box

Occupancy Counting Automatic Mask / Unmask of Alarms based on Occupancy Count Temporary User Controls

Use Count Limits (1-255 Uses) Temporary Day Limits (1-255 Days) Absentee-Rule Limits (1-255 Days) Disable or Delete On Expiration of

Temporary Users Regional per X-Box

Entry / Exit Delays For Alarm Control Extensive Zoning Capabilities of Alarms Alarm Input State Change and Mask

Status Reporting Alarm Action Features – TZ control of all options, Trigger CZ on Alarm and Secure

“Latch Monitor” function” with DTLM3 Door / Equipment Interlocking (Man

Traps, Sally Ports), and Misc. Input / Output Linking Applications

DIGI*TRAC Controller – Export, Import, Duplicate, and Drag & Drop controller configurations

User Partitioning Alarm Point Level Customization Alarm & Event Routing by Operator Interoperability SDK – Professional Services Support

- API for Users & Credentials

- XML for Monitoring and Control

Hirsch Electronics – 1900 Carnegie Ave., Bldg. B, Santa Ana, CA 92705 Web Site www.hirschelectronics.com Phone (949)250-8888 FAX (949)250-7372

SCRAMBLEPAD®

Patented Features Scrambling Display Viewing Restrictor

Additional Features Weather Resistant 3 - 15 Digit Codes - Simultaneously Duress Evenly Distributes Wear Supervised Physical Tamper CODE Tamper Includes MATCH Functionality Auto-Start of ScramblePad Option

When Dual Credential Required Extended Access Countdown Display Green LED Follows Door Relay

2 Versions (with Integrated MATCH Functionality) DS47L - ScramblePad DS47L-HI - ScramblePad with high intensity display for high ambient lighting conditions

Versions That Include Proximity (with Integrated MATCH Functionality)

DS47L-SPX (HID)

DS47L-SPX-HI (HID)

NOTE: Other proximity versions and Smart Card versions available

Mounting Boxes MB1 - Flush Mount MB2 - Surface Mount MB2S- Surface Mount, Shallow Depth MB2SL – Surface Mount, Sloped MB3 - Heavy Duty, Flush MB4 - Heavy Duty, Surface MB5 - Exterior, Surface MB8 - Heavy Duty, Flush, ADA MB9 - Heavy Duty, Surface, ADA MB10/11 – LCD Option MP35 - Mounting Post for MB5, 35”, for curb mounting MP41 - Mounting Post for MB5, 41”, ground level mounting UMK - Universal Mounting Kit (requires

MB2)

Standard Mounting Height - 58” ADA Mounting Height - 48” **NOTE**: Mounting Height Is Subject To Local Codes.

MATCH

Interface To Readers Other Than

ScramblePad ABA Format 26-55 Bit Standard Wiegand Format 75 Bit GSA Format One MRIB Required Per Door

**NOTE: MRIB available as board only (MRIB), or as an assembly (MRIA), which includes mounting base and bezel and requires Hirsch Mounting Box. Integrated MATCH functionality included standard with all DS47L ScramblePads. Separate MATCH required for custom formats.

MATCH - cont.

Readers Supported Magnetic Stripe Bar Code Wiegand Proximity Smart Card FIPS-201 PIV Readers Biometric

Hand Geometry Finger Print Retina Scan Iris Scan Facial Recognition

Smart Card / Biometric Combination

DIGI*TRAC

Controller Models Model M1N – 1 Door Access Control Model M2N2 - 2 Door Access Control Model M8N2 - 8 Door Access Control Model M16N2 - 16 Alarm Inputs Model MSPN2-8R – 8-32 Relay Outputs Model M64N2 – 64 Relay Outputs

Key Hardware Features NEMA Style Enclosure Conduit Knockouts Removable Door Medeco Key Lock Tampered Enclosure 10 AMP Door Relays Dedicated Alarm Relays Internal Power Supply UPS With Battery Memory Battery Fused Power Circuits Parallel Printer Port Relay Status LEDs Diagnostic LEDs CCM - Command & Control Module UL294 on Model 2 & 8 Single or Dual Technology, Entry and

Exit Readers on each door

DIGI*TRAC Expansion Options AEB8 - 8 Input Alarm Expansion Board REB8 - 8 Output Relay Expansion

Board SNIB - SCRAMBLE*NET Interface

Board (Built in to M1N) SNIB2 – Onboard 10/100 Ethernet

Input, 128 Bit AES Encryption MEB/BE - Memory Expansion Board, Buffer Expansion MEB/CB64 – Code Expansion to 68,000

Users MEB/CB128 – Code Expansion to

132,000 Users

**NOTE: All DIGI*TRAC controllers come standard with a SNIB installed. Each DIGI*TRAC controller can accommodate up to 5 total Expansion Boards (4 after counting the included SNIB), except the Model 64 can only accept 4 total. Only 1 MEB/CE or CB per controller and a maximum of 4 AEB8 per controller, except 2 AEB8 in Model 16. No REB8 can be added to Model 64. The Model 1N will not accept any Expansion Boards.

SCRAMBLE*NET

RS232 or RS485, Optically Isolated Encrypted - HES with SNIB Hardwired, Fiber Optic, Leased Line 1 Controller Up To 50’ on RS232 16 Controllers Daisy-Chained Up To

4,000’ on RS485 With Net*Adapt1 16 Controllers With NET*MUX4, Daisy-

Changed / Star Wiring NET*MUX4 - I Input, 4 Output. Each

Port RS232 or RS485 Dial-Up to Remote Sites

X-BOX

RS232 and RS485 Output Up To 16 Controllers Each Off-loads Controller Polling and

Encryption From PC

SNIB2 – XNET2 Protocol

10/100 Ethernet Input RS458 Output Downstream Built-In X-Box Functionality 128 Bit, NIST Certified, AES Encryption SNIB Downstream Support

WIRING REQUIREMENTS

DIGI*TRAC

Controller To Reader 2 Pair, Stranded, Twisted, Overall Shield

22 AWG - 750’

18 AWG - 1800’

Controller To Door Lock 1 Pair, Stranded, Twisted, Shielded 18 AWG (distance function of resistance)

**NOTE: Only Run In Same Conduit As Reader or Line Module Wiring if twisted, shielded.

Controller To Line Module 1 Pair, Stranded, Twisted, Shielded

22 AWG - 3000’ (DTLM2/MELM2)

SCRAMBLE*NET

RS485 - 2 Pair, Stranded, Twisted, Overall Shield, 22 AWG - 4,000’ RS485 downstream with SNIB2 – cat5 RS232 - 3 Conductor, Stranded, Overall Shield, 22 AWG - 50’

LINE SUPERVISION MODULES

Required For All Monitored Devices. Digitally Processed, Analog Inputs

2 Styles DTLM - Screw Terminals MELM - Flying Leads

3 Versions 1 Input - Alarm 2 Input - Alarm, RQE 3 Input - Alarm, RQE, Tamper

(VELOCITY VN3.1 FASTFACTS.DOC) 4/30/10