S02 - Drawings Vol 4 of 4.pdf
PDF 12 MB Posted
- Solicitation number
- 36C25224B0016
About this file
This document appears to be a set of drawings (Volume 4 of 4) related to the renovation of Inpatient Ward 7B at a Department of Veterans Affairs (VA) facility. The associated federal contract opportunity has the Solicitation Number 36C25224B0016 and the Contract ID 8f45970841a24940a8386cc2b4b8d807.
The project involves the renovation of Inpatient Ward 7B, located at a VA facility under the Veterans Integrated Service Network 12. The agency responsible for this project is the Department of Veterans Affairs Veterans Health Administration. The solicitation is for construction services to complete this renovation work. Key details about the required products, services, and timeline are not provided in this set of drawings, but would likely be included in the full solicitation documents.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| S06 - Updated Drawings - 0003.pdf | ||
| 36C25224B0016 0003.docx | DOCX document | |
| S06 - Updated Spec Sections - 0003.pdf | ||
| S06 - Drawing AC020204 - 0003.pdf | ||
| 36C25224B0016 0002.docx | DOCX document | |
| S06 - SF1442 Page 1 - Revised.pdf | ||
| S06 - Wage Determination Revised.pdf | ||
| 36C25224B0016 0001.docx | DOCX document | |
| S04 - Pre-Bid Attendance List.pdf | ||
| 36C25224B0016.docx | DOCX document | |
| S02 - Specs Vol 2 of 3.pdf | ||
| S02 - Specs Vol 1 of 3.pdf | ||
| S02 - Drawings Vol 2 of 4.pdf | ||
| S02 - Drawings Vol 1 of 4.pdf | ||
| S02 - Specs Vol 3 of 3.pdf | ||
| S02 - Drawings Vol 3 of 4.pdf |
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL NOTES:
DESIGNATIONSSYMBOL
MTG
HT
SYMBOL SCHEDULE NOTES
THESE SYMBOLS COMPRISE A STANDARD LIST, NOT ALL SYMBOLS MAY
APPEAR ON THESE DRAWINGS.
MOUNTING HEIGHTS INDICATED ARE STANDARD. DIMENSIONAL NUMBERS
INDICATED AT DEVICES SHALL OVERRIDE THESE STANDARDS. MOUNTED
HEIGHTS ARE TO THE CENTER OF THE DEVICE, UNLESS NOTED OTHERWISE.
MOUNTING HEIGHTS INDICATED ARE FOR STUD WALL CONSTRUCTION.
WHEN BLOCK OR BRICK CONSTRUCTION IS USED, ADJUST MOUNTING
HEIGHTS TO ALIGN DEVICE PLATES WITH RUNNING JOINT.
REFER TO SPECIFICATIONS FOR FURTHER INFORMATION.
GENERAL
HEAVY DASHED LINE WEIGHT INDICATES
EXISTING ITEM TO BE REMOVED.
LIGHT SOLID LINE WEIGHT INDICATES EXISTING
ITEM TO REMAIN.
HEAVY SOLID LINE WEIGHT INDICATES NEW
ITEM OR NEW LOCATION.
REMOVE EXISTING ITEM
REMOVE EXISTING ITEM AND RELOCATE AS INDICATED
NL
EXISTING ITEM TO REMAIN
NEW LOCATION FOR RELOCATED ITEM
NOTES & TAGS
EQUIPMENT IDENTIFICATION TAG - SEE EQUIPMENT SCHEDULES
FEEDER SIZE TAG - SEE POWER RISER SCHEDULE
ELEC EQUIP CONNECTION TAG - SEE EQUIP SCHEDULE
KEYNOTE
MISCELLANEOUS NOTE
#/C
XX
LIGHTING CONTROL SEQUENCE - SEE SCHEDULE
LC
XXX-X
RACEWAYS
CONDUIT CONCEALED IN CEILING OR WALLS
CONDUIT CONCEALED IN THE FLOOR OR BELOW
CONDUIT EXPOSED ON THE CEILING OR WALLS
CONDUIT BURIED UNDERGROUND (# = DEPTH)
CONDUIT WITH BEND DOWN
CONDUIT WITH BEND UP
CONDUIT WITH BUSHED END
CONDUIT WITH BREAK OR CONTINUATION
UG
CIRCUIT HOME RUN
- L1 INDICATES PANEL
- NUMBER
L1 1,3,5
PULL BOX, SIZE AS NOTED
JUNCTION BOX - WALL/CEILING MOUNT
WIREWAY, DUCT BANK, OR FLOOR DUCT AS NOTED
CABLE TRAY, TYPE/SIZE AS INDICATED
P B
J J
X
R
RL
ELECTRICAL ABBREVIATIONS
AMPERES
ABOVE
ADDENDUM
AVAILABLE FAULT CURRENT
ABOVE FINISHED FLOOR
AIR HANDLING UNIT
ALUMINUM
ANTENNA
A, AMP
ABV
ADD
AFC
AFF
AHU
AL
ANT
ABOVE COUNTERAC
ARC FAULT CIRCUIT INTERRUPTERAFCI
BELOW FINISHED CEILING
BOLTED PRESSURE SWITCH
BFC
BPS
AUTOMATIC TRANSFER SWITCHATS
BUILDING AUTOMATION SYSTEMBAS
COPPER
DISTRIBUTED ANTENNA SYSTEM
ELECTRICAL CONTRACTOR
ELECTRIC OR ELECTRICAL
EMERGENCY
ELECTRICAL METALLIC TUBING
ENCLOSURE
ELECTRIC PNEUMATIC
EMERGENCY POWER OFF
CU
DAS
EC
ELEC
EM
EMT
ENCL
EP
EPO
CONDUIT OR CONTROLLED RECEPT
CIRCUIT BREAKER
CLOSED CIRCUIT TV
CIRCUIT
CABINET
C
CAB
CB
CCTV
CKT
ELECTRIC WATER COOLER
FUSE OR FUSED
FIRE ALARM
FLOOR BOX
FIRE-SMOKE DAMPER
GROUND
GROUND FAULT CIRCUIT INTERRUPTER
ISOLATED GROUND
JUNCTION BOX
KILOVOLT
KILOVOLT-AMP
KILOWATT
KILOWATT-HOUR
FILM VIEWER
EWC
F
FA
FB
FSD
FV
G, GND
GFI, GFCI
IG
JBOX
KV
KVA
KW
KWH
MAIN CIRCUIT BREAKER
MOMENTARY CONTACT OR
NATIONAL ELECTRICAL CODE
NOT IN CONTRACT
NOT TO SCALE
ON CENTER
PULL BOX OR PUSHBUTTON
NORMALLY OPEN
NORMALLY CLOSED
MAIN SWITCHBOARD
MC
MCB
MSB
NC
NEC
NIC
NO
NTS
OC
PB
MAIN LUG ONLYMLO
MOTOR RATED SWITCHMRS
EMPTYMT
PNEUMATIC ELECTRIC
POWER FACTOR
PHASE
PRIMARY
PANEL
REFRIGERATOR
SECONDARY
SWITCH
SWITCHBOARD
SPEAKER
ROOF TOP UNIT
RECEPTACLE
TELEPHONE
PE
PF
PH
PNL
PRI
RECEPT
REFG
RTU
SEC
SW
SWBD
SPKR
TEL
TAMPER RESISTANTTR
THERMOSTAT
TYPICAL
UNDER COUNTER
UNDER GROUND
UNLESS NOTED OTHERWISE
VOLT OR VOLTAGE
VOLT-AMP
VOLTS ALTERNATING CURRENT
UNIT HEATER
VOLTS DIRECT CURRENT
WATT, WIRE OR WALL PHONE
WEATHERPROOF
EXISTING
TSTAT
TYP
UC
UG
UH
UNO
V
VA
VAC
VDC
W
WP
X
UNIVERSAL SERIAL BUSUSB
18"
18"
18"
18"
18"
18"
18"
VERIFY
VERIFY
VERIFY
VERIFY
VERIFY
VERIFY
VERIFY
VERIFY
VERIFY
VERIFY
18"
18"
18"
18"
BRANCH CIRCUIT PANEL
EQUIPMENT CABINET
TRANSFORMER
MOTOR OR MOTOR CONNECTION
MOTOR CONTROLLER, STARTER OR VFD
COMBINATION STARTER & DISCONNECT SWITCH
DISCONNECT SWITCH
MOTOR RATED TOGGLE
MANUAL MOTOR STARTER SWITCH WITH THERMAL
OVERLOAD
DUPLEX RECEPTACLE - WALL/CEILING MOUNT
EMERGENCY DUPLEX RECEPTACLE - WALL/CEILING
MOUNT
QUADPLEX RECEPTACLE - WALL/CEILING MOUNT
GFI RECEPTACLE, DUPLEX/QUADPLEX - WALL MOUNT
SPECIAL PURPOSE RECEPTACLE - WALL/CEILING
MOUNT
FLOOR BOX - DEVICES AS INDICATED
POWER POLE - DEVICES AS INDICATED
EMERGENCY SPECIAL PURPOSE RECEPTACLE -
WALL/CEILING MOUNT
MR
MMS
G G
P
DUPLEX RECEPTACLE - CONTROLLED - WALL/CEILING
MOUNT
C
SPLIT DUPLEX RECEPTACLE - WALL/CEILING MOUNT
SIMPLEX RECEPTACLE - WALL/CEILING MOUNT
EMERGENCY SIMPLEX RECEPTACLE - WALL/CEILING
MOUNT
GFI DEAD FRONT DEVICE, NORMAL/EMERGENCY - WALL
MOUNT
EMERGENCY QUADPLEX RECEPTACLE - WALL/CEILING
MOUNT
GROUND REFERENCE BUS - AS NOTED - WALL/CEILING
MOUNT
VERIFY
EMERGENCY SPLIT DUPLEX RECEPTACLE -
WALL/CEILING MOUNT
C
C
LIGHT FIXTURE ID - REFER TO LIGHT FIXTURE SCHEDULE
(SCHEDULE OVERRIDES SYMBOL ABBREVIATION)
A - INDICATES LIGHT FIXTURE TYPE
# - INDICATES CIRCUIT NUMBER
b - INDICATES SWITCHING
LIGHT FIXTURE CIRCUIT TYPE
- NO HATCH INDICATES NORMAL CIRCUIT
- ANGLED HATCH INDICATES CRITICAL CIRCUIT
- SOLID HATCH INDICATES LIFE SAFETY CIRCUIT
TROFFER TYPE LIGHT FIXTURE, SIZE AS INDICATED -
CEILING MOUNT
CHANNEL OR INDUSTRIAL, LENGTH AS INDICATED
ROUND DOWNLIGHT, RECESSED OR SURFACE MOUNT
CEILING WALL WASH FIXTURE OR TRACK HEAD
WALL MOUNT FIXTURE OR SCONCE
LINEAR RECESSED, LENGTH AS INDICATED
UNDER CABINET FIXTURE, LENGTH AS INDICATED
TRACK FIXTURE, NUMBER OF HEADS AS INDICATED
EMERGENCY BATTERY LIGHT - WALL/CEILING MOUNT
EXIT LIGHT, FILLED QUADRANT INDICATES FACES -
WALL/CEILING MOUNT
VERIFY
SITE LIGHTING ROUND OR SQUARE BOLLARD
SITE LIGHTING POLE FIXTURE, ROUND/RECTANGLE
HEAD - NUMBER OF HEADS INDICATED
b
A
LINEAR SUSPENDED , LENGTH AS INDICATED VERIFY
VERIFY
SQUARE DOWNLIGHT, RECESSED OR SURFACE MOUNT
CHANNEL OR INDUSTRIAL WALL MOUNT, LENGTH AS
INDICATED
ROUND OR SQUARE PENDANT
TAPE OR ROPE LIGHT
VANITY FIXTURE
WALL PACK
FLAG OR FLOOD LIGHT
VERIFY
VERIFY
SINGLE POLE TOGGLE SWITCH
DOUBLE POLE TOGGLE SWITCH
THREE WAY TOGGLE SWITCH
FOUR WAY TOGGLE SWITCH
TOGGLE SWITCH - "a" INDICATES SWITCHING a
48"
PILOT LIGHT TOGGLE SWITCH
ILLUMINATED TOGGLE - TOGGLE SWITCH
KEYED SWITCH
MOMENTARY CONTACT TOGGLE SWITCH
TIMER SWITCH
DIMMER SWITCH (# = WATTAGE)
OCCUPANCY SENSOR - CLG MOUNT
OCCUPANCY SENSOR WALL SWITCH
PHOTO ELECTRIC CELL
TIME CLOCK
CONTACTOR
RELAY
IL
K
MC
TS
OS
PUSH BUTTON STATION - BUTTONS AS INDICATED
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
48"
60"
60"
S
PC
TC
C
R
D#
MULTI SWITCH, MULTI GANG BOX 48"
VERIFY
VERIFY
PUSH BUTTON SWITCHB 48"
FIRE ALARM
MANUAL PULL STATION
HEAT DETECTOR (#=FIXED TEMP, R=RATE OF RISE)
SMOKE DETECTOR (P=PHOTOELECTRIC, I=IONIZATION)
DUCT MOUNTED PHOTOELECTRIC DETECTOR
BEAM DET (B-T=TRANSMITTER, B-R=RECEIVER)
COMBINATION SMOKE DETECTOR AND ALARM
REMOTE STATION - WALL/CEILING MOUNT
REMOTE INDICATOR LAMP - WALL/CEILING MOUNT
FLOW SWITCH
TAMPER SWITCH
MONITOR MODULE
CONTROL MODULE
FIRE/SMOKE DAMPER CONNECTION
DOOR HOLD OR DOOR HOLD CONNECTION
FIREMAN'S STATION - WALL MOUNT
STROBE - WALL/CEILING MOUNT (# = CANDELA)
BELL - WALL/CEILING MOUNT
BELL/STROBE - WALL/CEILING MOUNT (# = CANDELA)
CHIME - WALL/CEILING MOUNT
CHIME/STROBE - WALL/CEILING MOUNT (# = CANDELA)
HORN - WALL/CEILING MOUNT
HORN/STROBE - WALL/CEILING MOUNT (# = CANDELA)
SPEAKER - WALL/CEILING MOUNT
SPEAKER/STROBE - WALL/CEILING MOUNT
(# = CANDELA)
# R
P I
B-T
SA
RS RS
RI RI
FS
TS
MM
CM
SD
DH
48"
72"
72"
48"
82"
82"
82"
82"
82"
82"
82"
82"
82"
FIRE ALARM CONTROL PANEL - WALL MOUNT
F
F F
F F
F
F
F
F F
F F
F
F
F
F
F
F
F F
F F
F F
F F
F F
F F
F F S S
SS
FACP
FS
COMBINATION FIRE ALARM/MASS
NOTIFICATION: SPEAKER/STROBE -
WALL/CEILING MOUNT(# = CANDELA)
82"F A
S SA F
VERIFY
F F
F F C C
CC
SIGNAL AND COMMUNICATIONS
DATA BOX - WALL MOUNT (# = WIRE COUNTS)
VOICE/DATA BOX - WALL MOUNT/FLOOR
BOX (# = WIRE COUNTS)
VOICE BOX - WALL MOUNT (# = WIRE COUNTS)
DOUBLE GANG VOICE BOX - HIGH WALL MOUNT
WIRELESS ACCESS POINT - WALL/CEILING MOUNT
18"
SPEAKER - WALL/CEILING MOUNT
HORN SPEAKER - WALL MOUNT
VOLUME SWITCH - WALL MOUNT
AUDIO JACK (M=MICROPHONE, A=AUXILIARY)
BUZZER - WALL/CEILING MOUNT
BELL - WALL/CEILING MOUNT
CHIME - WALL/CEILING MOUNT
CLOCK - WALL/CEILING MOUNT (# = DIAMETER)
PROJECTOR/VIDEO CAMERA/DOCUMENT
CAMERA - WALL/CEILING MOUNT
TV SYSTEM OUTLET - WALL/CEILING MOUNT
ANNUNCIATOR PANEL - WALL MOUNT
60"
96"
48"
18"
18"
96"
VERIFY
18"
WALL INTERCOM STATION (M=MASTER, R=REMOTE) 48"
96"
96"
96"
18"
96"
W
PRJ
AUDIO VIDEO SYSTEM OUTLET - WALL/CEILING MOUNT 18"
A/V SYSTEMS CONTROLLER - WALL MOUNT 18"
S
S S
C C
IC
M
AM
V
VID
SECURITY
SECURITY - WALL MOUNT - TYPICAL
RX - REQUEST TO EXIT
ES - ELECTRIC STRIKE
EL - ELECTRIC LOCK
ML - MAGNETIC LOCK
TH - POWER TRANSFER HINGE
DC - DOOR CONTACT
ODC - OVERHEAD DOOR CONTACT
MS - MONITOR STRIKE
MD - MOTION DETECTOR
GB - GLASS BREAKER DETECTOR
48"
SECURITY PANEL - WALL MOUNT VERIFY
S
S
SECURITY
SECURITY CAMERA - WALL/CEILING MOUNT
VERIFY
CR - CARD READER
KP - KEYPAD
KS - KEY SWITCH
EP - EXIT PUSHBUTTON
M - MASTER STATION
SECURITY - CEILING MOUNT - TYPICAL
SWITCHES AND CONTROLS
LIGHTING
POWER
E - EMERGENCY PULL STATION
P - PATIENT STATION (ENHANCED)
C - CODE BLUE STATION
D - DUTY STATION
SA - STAFF ASSIST STATION
M - MASTER STATION
LOCATOR ANTENNA
DOME LIGHT - WALL/CEILING MOUNT (BLANK = 4 LIGHTS,
# = NUMBER OF LIGHTS, Z = ZONE INDICATOR LIGHTS)
96"
NURSE CALL PANEL - WALL MOUNT
BD - PATIENT BED STATION
C-B - CODE BABY STATION
AI - AUXILIARY INPUT STATION
N
N
N N
NCP
ANN - ANNUNCIATOR PANEL
NURSE CALL - WALL MOUNT - TYPICAL
C-B/SA - CODE BABY/STAFF ASSIST
COMBINATION STATION
C/SA - CODE BLUE/STAFF ASSIST
COMBINATION STATION
CC - CALL CANCEL
M1 - SECONDARY MASTER STATION
P1 - PATIENT STATION (BASIC)
TV - PATIENT TV STATION
WF - WORK FLOW (TOUCH SCREEN)
WF1 - WORK FLOW (4-BUTTON)
VERIFY
VERIFY
NURSE CALL
A.
B.
C.
D.
TRANSFORMERXFMR
ABOVE GRADEAG
AUDIBLE ALARMAA
CEILING CLG
DOWNDN
DEDICATEDDED
COMMUNICATIONSCOMM
CONTROL CTRL
FIRE ALARM ANNUNCIATOR PANELFAAP
FIRE ALARM CONTROL PANELFACP
FIBER OPTICFO
SINGLE MODE FIBER OPTICSMFO
MULTI MODE FIBER OPTICMMFO
GROUND FAULT EQUIPMENT PROTECTIONGFEP
GENERAL CONTRACTORGC
CURRENT TRANSFORMERCT
ABOVE COUNTER HEIGHTACH
AUDIO VISUALAV
AMERICAN WIRE GUAGEAWG
MOTOR CONTROL CENTERMCC
METER M
MAN HOLEMH
NEUTRALN
HAND HOLEHH
HAND OFF AUTOHOA
POTENTIAL TRANSFORMERPT
MECHANICAL CONTRACTOR
RACEWAYR
UNDER FLOORUF
WIRELESS ACCESS POINTWAP
SHIELDED TWISTED PAIRSTP
SUBSTATIONSUB
UNSHIELDED TWISTED PAIRUTP
ELECTRICAL GROUND BAREGB
SERVICE GROUND BARSGB
TELECOMMUNICATIONSTELCOM
TELECOMMUNICATIONS MAIN GROUND BARTMGB
TELECOMMUNICATIONS GROUND BARTGB
DESIGNATIONSSYMBOL
MTG
HT
DESIGNATIONSSYMBOL
MTG
HT
ELECTRICAL SYMBOLS LEGEND
VERIFY
VERIFY
VERIFY
VERIFY
C
18"
A/V MONITOR - WALL MOUNT 18"MT
CX
AV
TV
AV
TV
X" H X" W
X' - X" AFF
CABLE TRAY TAG
X" W - WIDTH OF CABLE TRAY
X" H - HEIGHT OF CABLE TRAY
X' - X" AFF - MOUNTING HEIGHT OF CABLE TRAY (FROM FINISH
FLOOR TO BOTTOM OF TRAY)
CC GFI RECEPTACLE, DUPLEX/QUADPLEX - CEILING MOUNT
18"
UTILITY SERVICE:
EQUIPMENT ID
VOLTAGE, PHASE, 3 OR 4 WIRE
ONE LINE AND RISER
ID
V, Ø, W
XX
AF/AT
XX
AF/AT
XX
AF/AT
XX
AF/AT
600 VOLT MOLDED CASE CIRCUIT BREAKER:
AF = AMP FRAME, AT = AMP TRIP
XX = OPTIONS TO BE PROVIDED, MAY BE BLANK
OPTIONS ABBREVIATIONS:
LSI = LONG TIME/SHORT TIME/INSTANTANEOUS TRIP SETTINGS
LSIG = LSI WITH GROUND FAULT PROTECTION
EO=ELECTRICALLY OPERATED
M1=METER (REFER TO METER SCHEDULE)
ST=SHUNT TRIP
K1=KIRK KEYED (REFER TO KIRK KEY SCHEDULE)
600 VOLT INSULATED CASE CIRCUIT BREAKER:
AF = AMP FRAME, AT = AMP TRIP
XX = OPTIONS TO BE PROVIDED, MAY BE BLANK
600 VOLT DRAWOUT CIRCUIT BREAKER:
AF = AMP FRAME, AT = AMP TRIP
XX = OPTIONS TO BE PROVIDED, MAY BE BLANK
15,000 VOLT DRAWOUT CIRCUIT BREAKER:
AF = AMP FRAME, AT = AMP TRIP
XX = OPTIONS TO BE PROVIDED, MAY BE BLANK
M A V
XX
ID
V, Ø, W
A MCB
SPACES
KAIC
XX
AS
DISCONNECT SWITCH:
AS = AMP SWITCH
XX = OPTIONS TO BE PROVIDED, MAY BE BLANK
XX
AF
FUSE:
AF = AMP FUSE
XX = OPTIONS TO BE PROVIDED, MAY BE BLANK
XX
AS/AF
FUSED DISCONNECT SWITCH:
AS = AMP SWITCH, AF = AMP FUSE
XX = OPTIONS TO BE PROVIDED, MAY BE BLANK
ID
KVA
V
ID
V, Ø, W A
XX
KAIC
ID
HP
Ø
ID
KW/KVA
V, Ø, W
PF
ENGINE GENERATOR:
EQUIPMENT ID
KW/KVA RATING OF GENERATOR
VOLTAGE, PHASE, 3 OR 4 WIRE, POWER FACTOR
TRANSFER SWITCH:
EQUIPMENT ID
VOLTAGE, PHASE, 3 OR 4 WIRE, AMP RATING
OPEN/CLOSED/DELAYED
CALCULATED FAULT CURRENT
MOTOR:
EQUIPMENT ID
HORSEPOWER, PHASE
FEEDER DESCRIPTION:
SEE ELECTRICAL ONE LINE SHEET FOR SCHEDULE
STATIC SWITCH
MOTOR OVERLOAD PROTECTION DEVICE
POTENTIAL TRANSFORMER:
TR = TURNS RATIO
PANELBOARD:
EQUIPMENT ID
VOLTAGE, PHASE, 3 OR 4 WIRE, AMP RATING
MCB OR MLO
SPACES AVAILABLE
CALCULATED FAULT CURRENT
ID
KVA
V
CURRENT TRANSFORMER:
TR = TURNS RATIO
LIGHTNING ARRESTER
GROUND CONNECTION
CAPACITOR
BATTERY
CONTACTOR - NORMALLY OPEN
CONTACTOR - NORMALLY CLOSED
PULLBOX
METER:
M = WATTHOUR METER, A = AMMETER, V = VOLT METER
LINEWORK:
EQUIPMENT ENCLOSURE LINE
SWITCHGEAR BUS LINE
BUSWAY
NEW WORK
EXISTING WORK
DEMO WORK
FUTURE WORK
TRANSFORMER WITH SPECIAL CORE:
EQUIPMENT ID
KVA RATING OF TRANSFORMER
PRIMARY VOLTAGE
SECONDARY VOLTAGE
TRANSFORMER:
EQUIPMENT ID
KVA RATING OF TRANSFORMER
PRIMARY VOLTAGE
SECONDARY VOLTAGE
ID
TR:XX
ID
TR:XX
NO
NC
DESIGNATIONSSYMBOL
MTG
HT
IC - INTERCOM
PULLBOX
A.
B.
C.
D.
E.
F.
G.
BUILDING WILL BE IN USE DURING CONSTRUCTION. SCHEDULE AND
CARRY OUT THE WORK IN SUCH A MANNER AS TO CAUSE THE OWNER A
MINIMUM OF INCONVENIENCE DUE TO SERVICE INTERRUPTION.
PROVIDE TEMPORARY SERVICES (FEEDER, BRANCH CIRCUIT, AND
SIGNAL SYSTEMS) IF ONE AREA OR PHASE OF CONSTRUCTION
DISRUPTS SERVICE TO ANOTHER AREA OF THE BUILDING(S) OR IF THE
EQUIPMENT, CONDUITS, OR FEEDERS HAVE TO BE RELOCATED TO
ALLOW CONSTRUCTION TO PROGRESS.
SERVICE INTERRUPTIONS SHALL BE CONFINED TO THE SMALLEST AREA
POSSIBLE AT ANY ONE TIME AND INTERRUPTIONS SHALL BE
SCHEDULED WITH THE OWNER'S SITE REPRESENTATIVE. AFTER
SERVICE HAS BEEN RESTORED FOLLOWING AN INTERRUPTION,
INSPECT AREAS AFFECTED BY THE INTERRUPTION AND BE
RESPONSIBLE FOR RETURNING AUTOMATICALLY CONTROLLED
EQUIPMENT TO THE SAME OPERATING CONDITION WHICH EXISTED
PRIOR TO THE INTERRUPTION.
ALL CORE DRILLING OR ANY ACTIVITIES CAUSING EXTREME VIBRATION
OR NOISE SHALL BE COORDINATED TO BE PERFORMED AFTER
BUSINESS HOURS TO NOT AFFECT CRITICAL HOSPITAL FUNCTIONS
WITHIN ADJACENT AREAS. COORDINATE WITH VA REPRESENTATIVE AS
REQUIRED.
REMOVE, REPLACE, RELOCATE, OR PROVIDE ANY ELECTRICAL DEVICES
AND/OR ANY CONDUIT/WIRING AS REQUIRED TO COMPLETE
REMODELING AS INDICATED IN THE CONTRACT DOCUMENTS.
DRAWINGS INDICATE EXISTING CONDITIONS AS THEY WERE INDICATED
ON OWNER PROVIDED AS-BUILT DRAWINGS AND SITE VERIFICATION.
ACTUAL CONDITIONS MAY VARY FROM THE CONDITIONS INDICATED.
FIELD VERIFY EXACT CONDITIONS.
ALL DEVICES, EQUIPMENT, CABLING, ETC. INDICATED IN THE CONTRACT
DOCUMENTS TO BE REMOVED SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO DISPOSE OF IN ACCORDANCE WITH LOCAL AND
FEDERAL REGULATIONS. REFER TO SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
DEMOLISH HOME RUN WIRING BACK TO SOURCE UNLESS NOTED
OTHERWISE. DO NOT LEAVE CONDUCTORS ABANDONED.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT OF RECORD
A/E:
STAMPCONSULTANTS
o n e e ig h th in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s in c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h e s o n e f o o t th re e in c h e s o n e f o o t
A
2 3 4 5 6
B
C
D
1 2 3 4 5 6
A
B
C
D
FOR OFFICIAL USE ONLY
MECHANICAL / ELECTRICAL / PLUMBING: STRUCTURAL:HEALTHCARE ARCHITECT:
2550 UNIVERSITY AVE. W. SUITE 423-S
ST. PAUL, MN 55114
651.251.7570
50 SOUTH 6TH ST UNIT 1100
MINNEAPOLIS, MN 55402
612.465.7550
380 ST. PETER ST. UNIT 600
ST. PAUL, MN 55102
651.222.3701
C U s e rs
\b e n z \D o c u m e n ts \2
M
D I n
P a t
B
E
B e n .Z u rn
.r v t
/1
/2
:4
:4
P
M
E000
ELECTRICAL TITLE SHEET
Stone Group Architects
600 E 7th Street
Sioux Falls, SD 57103
605-271-1144
VA Madison Renovate Inpatient Ward
7B
2500 Overlook Terrace, Madison, WI 53705
05/17/2024 JK BZ
100% CONSTRUCTION
DOCUMENTS
SGA #231919
VA #607-22-101
ELECTRICAL SHEET LIST
SHEET
NUMBER SHEET NAME
E000 ELECTRICAL TITLE SHEET
ED171 7TH LEVEL - DEMOLITION ELECTRICAL LIGHTING PLAN
ED172 7TH LEVEL - DEMOLITION ELECTRICAL POWER PLAN
ED173 7TH LEVEL - DEMOLITION ELECTRICAL SYSTEMS PLAN
ED181 8TH LEVEL - DEMOLITION ELECTRICAL DEMOLITION PLAN
ED191 PENTHOUSE/ROOF - DEMOLITION ELECTRICAL PLAN
EL171 7TH LEVEL - LIGHTING PLAN AREA A
EL172 7TH LEVEL - LIGHTING PLAN AREA B
EL191 PENTHOUSE/ROOF - ELECTRICAL LIGHTING PLAN
EP171 7TH LEVEL - POWER PLAN AREA A
EP172 7TH LEVEL - POWER PLAN AREA B
EP181 LEVEL 8 - ELECTRICAL POWER PLAN
EP191 PENTHOUSE/ROOF - ELECTRICAL POWER PLAN
EY171 7TH LEVEL - SYSTEMS PLAN AREA A
EY172 7TH LEVEL - SYSTEMS PLAN AREA B
EE300 ELECTRICAL RISER
EE301 ELECTRICAL RISER
EE500 ELECTRICAL DETAILS
EE600 ELECTRICAL SCHEDULES
EE601 ELECTRICAL SCHEDULES
SHEET TOTAL: 20
EXAMPLES:
NHD-B1A1 = NORMAL POWER, 277/480V, DISTRIBUTION BOARD LOCATED
ON THE FIRST FLOOR, AND IS THE FIRST PANEL IN AREA A.
LLP-BB1 = LIFE SAFETY POWER, 120/208V, PANEL BOARD LOCATED ON
THE BASEMENT FLOOR, AND IS THE FIRST PANEL IN AREA B
CT-P1 = CRITICAL POWER, TRANSFORMER LOCATED ON THE
PENTHOUSE LEVEL AND IS THE FIRST TRANSFORMER.
PANEL NUMBER (IF NEEDED):
• 1 - FIRST PANEL
• 2 - SECOND PANEL
AREA (IF NEEDED):
• A - AREA A
• B - AREA B
FLOOR/LEVEL (IF NEEDED):
• B - BASEMENT OR L-LOWER LEVEL
• 1 - FIRST FLOOR OR FIRST LEVEL
• 2 - SECOND FLOOR OR SECOND LEVEL
• P - PENTHOUSE
EQUIPMENT TYPE:
• D - DISTRIBUTION
• P - PANELBOARD
• T - TRANSFORMER
• SB - SWITCHBOARD
• SG - SWITCHGEAR
• ATS - AUTOMATIC TRANSFER SWITCH
• MTS - MANUAL TRANSFER SWITCH
• GPC - GENERATOR PARALLELING CABINET
• UPS - UNINTERRUPTIBLE POWER SUPPLY
• PDU - POWER DISTRIBUTION UNIT
• IPP - ISOLATED POWER PANEL
EQUIPMENT VOLTAGE:
• H-277/480V
• L-120/208V
• M-ABOVE 480V
• BLANK IF MULTI VOLTAGE
SYSTEM:
• N - NORMAL
• EM - EMERGENCY
• R - LEGALLY REQUIRED
• O - OPTIONAL STANDBY
• L - LIFE SAFETY
• E - EQUIPMENT
• C - CRITICAL
EQUIPMENT NAMING MATRIX:
Revision# Description Date:
KEY NOTES:
Tectonic Copyright 2007
T ectonic Cop yright 2007
Tectonic Copyright 2007
T ectonic Cop yright 2007
T ectonic Cop yright 2007
Tectonic Copyright 2007
Tectonic Copyright 2007
T ectonic Cop yright 2007
T ectonic Cop yright 2007
T ectonic Cop yright 2007
T ectonic Cop yright 2007
Tectonic Copyright 2007
T ectonic Cop yright 2007
T ectonic Cop yright 2007
T ectonic Cop yright 2007
Tectonic Copyright 2007
1 SALVAGE AND RETURN SPECIALIZED EPILEPSY LIGHT TO OWNER.
18 19 20 21 22 23 24 25 26 27 28 29
D
E
C
G
NORTH
KEY PLAN - B-WING OVERALL
B
A
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT OF RECORD
A/E:
STAMPCONSULTANTS
o n e e ig h th in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s in c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h e s o n e f o o t th re e in c h e s o n e f o o t
A
2 3 4 5 6
B
C
D
1 2 3 4 5 6
A
B
C
D
FOR OFFICIAL USE ONLY
MECHANICAL / ELECTRICAL / PLUMBING: STRUCTURAL:HEALTHCARE ARCHITECT:
2550 UNIVERSITY AVE. W. SUITE 423-S
ST. PAUL, MN 55114
651.251.7570
50 SOUTH 6TH ST UNIT 1100
MINNEAPOLIS, MN 55402
612.465.7550
380 ST. PETER ST. UNIT 600
ST. PAUL, MN 55102
651.222.3701
C U s e rs
\b e n z \D o c u m e n ts \2
M
D I n
P a t
B
E
B e n .Z u rn
.r v t
/1
/2
:4
:4
P
M
ED171
7TH LEVEL - DEMOLITION
ELECTRICAL LIGHTING PLANStone Group Architects
600 E 7th Street
Sioux Falls, SD 57103
605-271-1144
VA Madison Renovate Inpatient Ward
7B
2500 Overlook Terrace, Madison, WI 53705
05/17/2024 JK BZ
100% CONSTRUCTION
DOCUMENTS
SGA #231919
VA #607-22-101
1/8" = 1'-0"
LEVEL 7 - DEMOLITION LIGHTING PLAN
T ectonic Cop yright 2007
Tectonic Copyright 2007
T ectonic Cop yright 2007
T ectonic Cop yright 2007
Tectonic Copyright 2007
Tectonic Copyright 2007
T ectonic Cop yright 2007
T ectonic Cop yright 2007
T ectonic Cop yright 2007
T ectonic Cop yright 2007
Tectonic Copyright 2007
T ectonic Cop yright 2007
T ectonic Cop yright 2007
T ectonic Cop yright 2007
Tectonic Copyright 2007
J J
J
J
J J
KEY NOTES:
18 19 20 21 22 23 24 25 26 27 28 29
D
E
C
G
CR-B7L-1
CR-B7L-2 B7L-1E
B7L-2C
B7L-1C
LS-B7L-1
1 MAINTAIN EXISTING CONDUIT AND CONDUCTORS. SEE RISER FOR
ADDITIONAL INFORMATION
NORTH
KEY PLAN - B-WING OVERALL
B
A
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT OF RECORD
A/E:
STAMPCONSULTANTS
o n e e ig h th in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s in c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h e s o n e f o o t th re e in c h e s o n e f o o t
A
2 3 4 5 6
B
C
D
1 2 3 4 5 6
A
B
C
D
FOR OFFICIAL USE ONLY
MECHANICAL / ELECTRICAL / PLUMBING: STRUCTURAL:HEALTHCARE ARCHITECT:
2550 UNIVERSITY AVE. W. SUITE 423-S
ST. PAUL, MN 55114
651.251.7570
50 SOUTH 6TH ST UNIT 1100
MINNEAPOLIS, MN 55402
612.465.7550
380 ST. PETER ST. UNIT 600
ST. PAUL, MN 55102
651.222.3701
C U s e rs
\b e n z \D o c u m e n ts \2
M
D I n
P a t
B
E
B e n .Z u rn
.r v t
/1
/2
:4
:4
P
M
ED172
7TH LEVEL - DEMOLITION
ELECTRICAL POWER PLANStone Group Architects
600 E 7th Street
Sioux Falls, SD 57103
605-271-1144
VA Madison Renovate Inpatient Ward
7B
2500 Overlook Terrace, Madison, WI 53705
05/17/2024 JK BZ
100% CONSTRUCTION
DOCUMENTS
SGA #231919
VA #607-22-101
1/8" = 1'-0"
LEVEL 7 - DEMOLITION POWER PLAN
T ectonic Cop yright 2007
Tectonic Copyright 2007
T ectonic Cop yright 2007
T ectonic Cop yright 2007
Tectonic Copyright 2007
Tectonic Copyright 2007
T ectonic Cop yright 2007
T ectonic Cop yright 2007
T ectonic Cop yright 2007
T ectonic Cop yright 2007
Tectonic Copyright 2007
T ectonic Cop yright 2007
T ectonic Cop yright 2007
T ectonic Cop yright 2007
Tectonic Copyright 2007
N
N
N N
N
N N
N N
N
N
N
N
N N
N
N
NN
N
N
N
N
N
N
N N N N NN NN
NN NN N N N N NN NN N N N N NN N N N N
N
N
N
N
N N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
NN
N N
N
N N
N
N
N
N N
N
N
J
JJ
J
J J
J
J
J
J
J
N
J
J J
J
F
FF
F
F
F
F
F S
F S
F S
F S
F S
F S
F
F
FF
F
MMM
SSSSSSSSS
F
F
F
J
J J J J J J J J J
JJJJJJ
KEY NOTES:
18 19 20 21 22 23 24 25 26 27 28 29
D
E
C
G
1 DISCONNECT EPILEPSY CAMERA AND INFRARED ILLUMINATOR. TURN
OVER CAMERA, INFRARED ILLUMINATOR AND CEILING TILE TO OWNER
FOR REUSE.
NORTH
KEY PLAN - B-WING OVERALL
B
A
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT OF RECORD
A/E:
STAMPCONSULTANTS
o n e e ig h th in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s in c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h e s o n e f o o t th re e in c h e s o n e f o o t
A
2 3 4 5 6
B
C
D
1 2 3 4 5 6
A
B
C
D
FOR OFFICIAL USE ONLY
MECHANICAL / ELECTRICAL / PLUMBING: STRUCTURAL:HEALTHCARE ARCHITECT:
2550 UNIVERSITY AVE. W. SUITE 423-S
ST. PAUL, MN 55114
651.251.7570
50 SOUTH 6TH ST UNIT 1100
MINNEAPOLIS, MN 55402
612.465.7550
380 ST. PETER ST. UNIT 600
ST. PAUL, MN 55102
651.222.3701
C U s e rs
\b e n z \D o c u m e n ts \2
M
D I n
P a t
B
E
B e n .Z u rn
.r v t
/1
/2
:4
:4
P
M
ED173
7TH LEVEL - DEMOLITION
ELECTRICAL SYSTEMS PLANStone Group Architects
600 E 7th Street
Sioux Falls, SD 57103
605-271-1144
VA Madison Renovate Inpatient Ward
7B
2500 Overlook Terrace, Madison, WI 53705
05/17/2024 JK BZ
100% CONSTRUCTION
DOCUMENTS
SGA #231919
VA #607-22-101
1/8" = 1'-0"
LEVEL 7 - DEMOLITION SYSTEMS PLAN
J
J J J
J
J
J
J
1 RELOCATE ELECTRICAL DEVICE FOR NEW SHAFT.
18 19 20 21 22 23 24 25 26 27 28 29
D
E
C
G
11 1
NORTH
KEY PLAN - B-WING OVERALL
B
A
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT OF RECORD
A/E:
STAMPCONSULTANTS
o n e e ig h th in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s in c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h e s o n e f o o t th re e in c h e s o n e f o o t
A
2 3 4 5 6
B
C
D
1 2 3 4 5 6
A
B
C
D
FOR OFFICIAL USE ONLY
MECHANICAL / ELECTRICAL / PLUMBING: STRUCTURAL:HEALTHCARE ARCHITECT:
2550 UNIVERSITY AVE. W. SUITE 423-S
ST. PAUL, MN 55114
651.251.7570
50 SOUTH 6TH ST UNIT 1100
MINNEAPOLIS, MN 55402
612.465.7550
380 ST. PETER ST. UNIT 600
ST. PAUL, MN 55102
651.222.3701
C U s e rs
\b e n z \D o c u m e n ts \2
M
D I n
P a t
B
E
B e n .Z u rn
.r v t
/1
/2
:4
:4
P
M
ED181
8TH LEVEL - DEMOLITION
ELECTRICAL DEMOLITION PLANStone Group Architects
600 E 7th Street
Sioux Falls, SD 57103
605-271-1144
VA Madison Renovate Inpatient Ward
7B
2500 Overlook Terrace, Madison, WI 53705
05/17/2024 JK BZ
100% CONSTRUCTION
DOCUMENTS
SGA #231919
VA #607-22-101
1/8" = 1'-0"
LEVEL 8 - DEMOLITION ELECTRICAL PLAN
18 19 20 21 22 23 24 25 26 27 28 29
D
E
C
G
LP
LP
LP LP LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP LP LP
LP
LPLP
LPLP
LP
RL
1 TEMPORARILY REMOVE LIGHTNING PROTECTION AFFECTED BY NEW
PENTHOUSE. PROTECT AIR TERMINALS, CONDUCTORS AND FITTINGS
FOR REINSTALLATION.
EXTEND CIRCUIT TO LIFE SAFETY PENTHOUSE LIGHT FIXTURES.
EXTEND LIGHTING SWITCH LEGS TO NEW SWITCH LOCATION FOR
PENTHOUSE EXTENSION.
NORTH
KEY PLAN - B-WING OVERALL
B
A
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT OF RECORD
A/E:
STAMPCONSULTANTS
o n e e ig h th in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s in c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h e s o n e f o o t th re e in c h e s o n e f o o t
A
2 3 4 5 6
B
C
D
1 2 3 4 5 6
A
B
C
D
FOR OFFICIAL USE ONLY
MECHANICAL / ELECTRICAL / PLUMBING: STRUCTURAL:HEALTHCARE ARCHITECT:
2550 UNIVERSITY AVE. W. SUITE 423-S
ST. PAUL, MN 55114
651.251.7570
50 SOUTH 6TH ST UNIT 1100
MINNEAPOLIS, MN 55402
612.465.7550
380 ST. PETER ST. UNIT 600
ST. PAUL, MN 55102
651.222.3701
C U s e rs
\b e n z \D o c u m e n ts \2
M
D I n
P a t
B
E
B e n .Z u rn
.r v t
/1
/2
:4
:4
P
M
ED191
PENTHOUSE/ROOF - DEMOLITION
ELECTRICAL PLANStone Group Architects
600 E 7th Street
Sioux Falls, SD 57103
605-271-1144
VA Madison Renovate Inpatient Ward
7B
2500 Overlook Terrace, Madison, WI 53705
05/17/2024 JK BZ
100% CONSTRUCTION
DOCUMENTS
SGA #231919
VA #607-22-101
1/8" = 1'-0"
PENTHOUSE - DEMOLITION ELECTRICAL PLAN
FEC
D
D D D D D DD
D
D
D
D
D
DD
D D
D
D
DDDDDD
D
D D D D D D
D
D
D D D D D D
D
D
D D D D D D
D
D
D D
D D
D
D D D D
D D D
D
D
LC
LC
LC
3 LC
LC
LC
LC
LC
4D
LC
4D
LC
4D
LC
4D
LC
4D
LC
4D
LC
4D
LC
4D
D
D
PROVIDE UL924 UL RELAY FOR EMERGENCY LIGHTING.1
EQUIP.
STORAGE
B7095
PATIENT RM
B7098
PATIENT RM
B7094
PATIENT RM
B7092
PATIENT RM
B7080
EPI PATIENT RM
B7086
PATIENT RM
B7082
EPI PATIENT RM
B7088
PAT TLT
B7098A
PAT TLT
B7094A
PAT TLT
B7088A
PAT TLT
B7092A
PAT TLT
B7086A
PAT TLT
B7082A
PAT TLT
B7076B
PAT TLT
B7080A
PAT TLT
B7089A
STAFF TLT
B7097
LOCKER
B7099A
BREAK / CONF
B7099
MEDS ALCOVE
B7121J
NURSE ALCOVE
B7121H
NURSE ALCOVE
B7121G
NOURISH
B7085
NURSE STATION
B7081
CORRIDOR
B7121
CLEAN LINEN
B7091
CLEAN UTILITY
B7087
CONSULT
B7081B
SHARED
EPI/PM&R
B7093
CRASH CART
B7121E
ELEC
B7121F
EQUIP.
B7121I
23 24 25 26 27 28 29
D
E
C
G
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1 26
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
D6
D6
D6
D6
B1
B1
B1
B1
D6
D6
W4
D6
D6
D6
D6
D6
D6
D6
D6
D6
D6
W4
D6
D6
W4
D6
D6
D6
D6
D6
D6
D6
D6
D6
D6
W4
D6
D6
W4
D6
D6
D6
D6
D6
D6
D6
D6
D6
D6
W4
D6
D6
D6
D6
D6
D6
W4
D6
D6
D6
D6
D6
D6
D6
PATIENT RM
B7089
D6
D6
W4
D6
D6
D6
D6
N
N
B1
B1
C1
D5
D6
C124
D5
D6
C1
D5
D6
N
N
D6
D5
C1
C1
D5
D6
N
N
C1
D6
D5
C1
D5
D6
N
N
C1
D6
D5
C1
D5
D6
C1
E1
D6
D6
B1
U4
U3
U3
U3
U3
U2
U2
U3
U3
U3 a b c d f a b c f g a b c d f b c d f g a b c d f a b c g f a b fdc g d g a g d g h g g a b b c f f c d c c c g d a a c c c b c c f g g b a a c c f g f f f f d a d d b b c b b b f f g b b a c c c c d c g d f f a c b c c c c a f g f b a a c c c d cc f f g a b c f g d a a a a bbbb b b bb a c d a a a a b g g f d c d d d d d d d d d d
U4
U2
NORTH
KEY PLAN - B-WING AREA A
B
A
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT OF RECORD
A/E:
STAMPCONSULTANTS
o n e e ig h th in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s in c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h e s o n e f o o t th re e in c h e s o n e f o o t
A
2 3 4 5 6
B
C
D
1 2 3 4 5 6
A
B
C
D
FOR OFFICIAL USE ONLY
MECHANICAL / ELECTRICAL / PLUMBING: STRUCTURAL:HEALTHCARE ARCHITECT:
2550 UNIVERSITY AVE. W. SUITE 423-S
ST. PAUL, MN 55114
651.251.7570
50 SOUTH 6TH ST UNIT 1100
MINNEAPOLIS, MN 55402
612.465.7550
380 ST. PETER ST. UNIT 600
ST. PAUL, MN 55102
651.222.3701
C U s e rs
\b e n z \D o c u m e n ts \2
M
D I n
P a t
B
E
B e n .Z u rn
.r v t
/1
/2
:5
:0
P
M
EL171
7TH LEVEL - LIGHTING PLAN AREA A
Stone Group Architects
600 E 7th Street
Sioux Falls, SD 57103
605-271-1144
VA Madison Renovate Inpatient Ward
7B
2500 Overlook Terrace, Madison, WI 53705
05/17/2024 JK BZ
100% CONSTRUCTION
DOCUMENTS
SGA #231919
VA #607-22-101
1/4" = 1'-0"
LEVEL 7 AREA A - LIGHTING PLAN
D
D D D
D
D
D
D
D D
D
D
D D
D D
D
D
D
D
D
D D
D
D D
D
D
D
D
D D
D
D
D
D
D
D
D
D D
D D
D D
DD
D
D
D D
D D
D
D D D D D
D
D
D D
D
D
D D
D
D
D D D
D D D
D
D
D
D
LC
D
D
D
LC
LC
LC
LC
LC
LC
4D
LC
4D
LC
4D
LC
4D
LC
4D
LC
4D
LC
4D
LC
4D
LC
4D
LC
4D
D
KEY NOTES:
D6
D6
C1
D6
D5
W4
D6
D6
D6
ISO PATIENT RM
B7074A
ISO PATIENT RM
B7076A
PATIENT RM
B7070
PATIENT RM
B7068PATIENT RM
B7064ISO PATIENT RM
B7062A
ISO PATIENT RM
B7063A
EPI/BARI
PATIENT RM
B7065
BARI PATIENT
RM
B7069
PATIENT RM
B7071
PAT TLT
B7074B
PAT TLT
B7070A
PAT TLT
B7064A
PAT TLT
B7068A
PAT TLT
B7062B
PAT TLT
B7063B
PAT TLT
B7065A
PAT TLT
B7069A
PAT TLT
B7071A
ANTE
B7074
ANTE
B7076
ANTE
B7062
ANTE
B7063 NURSE
MANAGER
B7077
ASSIST NURSE
MANGER
B7060
SOILED UTILITY
B7073
MEDS
B7081A
MEDS ALCOVE
B7121B
NURSE ALCOVE
B7121A
HSKPG
B7059
PT TREATMENT
B7061
ELEC
B7121D
EQUIP.
B7121C
18 19 20 21 22
D
E
C
G
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
D6
N
N
D6
D6
D6
D6
D6
D6
W4
D6
D6
W4
D6
D6
D6
D6
N
C1
D5
D6
D5 9
C1
D6
D6
D6
D6
D6
W4
C1
D6
D6
D641
D6
W4
D6
D6
W4
D6
D641
D6
D6
D6
D6
W4
D6
D6
D6
D6
D6
W4
D6
D6
D6
W4
D6
D6
D6
D6
D6
D6
D6
D6
W4
D6
D6
D6
D6
D6
D6
D6
D6
D6
C1
N
N
N
N
C1
D5
D6
C1
D5
D6
D5
C1
D5
D6
D6
C1
D6
D5
C1
N
D6
E21
E1
N
N
U5
U3
U3
U3
U4
U4
U5
U2
U2
U3
U4
U1 b a c d
D6
D5 a a b c c c c c d g h h g cb d a f g a b c d f g a b c f g a b d f h c d b a g h d g c d d d dd a b b g f f a b b c c c c c ff d c b c a a c dg c c f g g a b a f f f f f hh g d c c cd c c baa h g h c d a b a b c f g h i j k l a b c f g a b d m d a b h g h c c c c d c b a c c a a a d g g f h h j l m j k jj j c d aa a aa b f g g i c d c c c c c c
U2
NORTH
KEY PLAN - B-WING AREA B
B
A
PROVIDE UL924 UL RELAY FOR EMERGENCY LIGHTING.1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT OF RECORD
A/E:
STAMPCONSULTANTS
o n e e ig h th in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s in c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h e s o n e f o o t th re e in c h e s o n e f o o t
A
2 3 4 5 6
B
C
D
1 2 3 4 5 6
A
B
C
D
FOR OFFICIAL USE ONLY
MECHANICAL / ELECTRICAL / PLUMBING: STRUCTURAL:HEALTHCARE ARCHITECT:
2550 UNIVERSITY AVE. W. SUITE 423-S
ST. PAUL, MN 55114
651.251.7570
50 SOUTH 6TH ST UNIT 1100
MINNEAPOLIS, MN 55402
612.465.7550
380 ST. PETER ST. UNIT 600
ST. PAUL, MN 55102
651.222.3701
C U s e rs
\b e n z \D o c u m e n ts \2
M
D I n
P a t
B
E
B e n .Z u rn
.r v t
/1
/2
:5
:1
P
M
EL172
7TH LEVEL - LIGHTING PLAN AREA B
Stone Group Architects
600 E 7th Street
Sioux Falls, SD 57103
605-271-1144
VA Madison Renovate Inpatient Ward
7B
2500 Overlook Terrace, Madison, WI 53705
05/17/2024 JK BZ
100% CONSTRUCTION
DOCUMENTS
SGA #231919
VA #607-22-101
1/4" = 1'-0"
LEVEL 7 AREA B - LIGHTING PLAN
F E
J
KEY NOTES:
18 19 20 21 22 23 24 25 26 27 28 29
D
E
C
G
F8F8F8F8
F8 F8 F8 F8
D16
D16
R2
F8
2 2
3 3 3
6 6 6 6
66 6 6
F8
1 EXISTING OBSTRUCTION LIGHTING FOR HELIPAD ON ROOF. EXTEND
EXISTING CIRCUIT TO NEW LIGHTS.
EXTEND LIFE SAFETY CIRCUIT.
EXTEND NORMAL POWER CIRCUIT.
EXTEND LIGHT SWITCH LEG FROM EXTENSION OF PENTHOUSE.
NEW OBSTRUCTION LIGHTING FOR HELIPAD ON ROOF.
CHAIN HANG LIGHT FIXTURE 8' AFF.
NORTH
KEY PLAN - B-WING OVERALL
B
A
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT OF RECORD
A/E:
STAMPCONSULTANTS
o n e e ig h th in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s in c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h e s o n e f o o t th re e in c h e s o n e f o o t
A
2 3 4 5 6
B
C
D
1 2 3 4 5 6
A
B
C
D
FOR OFFICIAL USE ONLY
MECHANICAL / ELECTRICAL / PLUMBING: STRUCTURAL:HEALTHCARE ARCHITECT:
2550 UNIVERSITY AVE. W. SUITE 423-S
ST. PAUL, MN 55114
651.251.7570
50 SOUTH 6TH ST UNIT 1100
MINNEAPOLIS, MN 55402
612.465.7550
380 ST. PETER ST. UNIT 600
ST. PAUL, MN 55102
651.222.3701
C U s e rs
\b e n z \D o c u m e n ts \2
M
D I n
P a t
B
E
B e n .Z u rn
.r v t
/1
/2
:5
:1
P
M
EL191
PENTHOUSE/ROOF - ELECTRICAL
LIGHTING PLANStone Group Architects
600 E 7th Street
Sioux Falls, SD 57103
605-271-1144
VA Madison Renovate Inpatient Ward
7B
2500 Overlook Terrace, Madison, WI 53705
05/17/2024 JK BZ
100% CONSTRUCTION
DOCUMENTS
SGA #231919
VA #607-22-101
1/8" = 1'-0"
PENTHOUSE - LIGHTING PLAN
J J J J J J J
J
J J
JJ
KEY NOTES:
EQUIP.
STORAGE
B7095
PATIENT RM
B7098
PATIENT RM
B7094
PATIENT RM
B7092
PATIENT RM
B7080
EPI PATIENT RM
B7086
PATIENT RM
B7082
EPI PATIENT RM
B7088
PATIENT RM
B7089
PAT TLT
B7098A
PAT TLT
B7094A
PAT TLT
B7088A
PAT TLT
B7092A
PAT TLT
B7086A
PAT TLT
B7082A
PAT TLT
B7076B
PAT TLT
B7080A
PAT TLT
B7089A
STAFF TLT
B7097
LOCKER
B7099A
BREAK / CONF
B7099
MEDS ALCOVE
B7121J
NURSE ALCOVE
B7121H
NURSE ALCOVE
B7121G
NOURISH
B7085
NURSE STATION
B7081
CORRIDOR
B7121
CLEAN LINEN
B7091
CLEAN UTILITY
B7087
CONSULT
B7081B
SHARED
EPI/PM&R
B7093
CRASH CART
B7121E
ELEC
B7121F
EQUIP.
B7121I
23 24 25 26 27 28 29
D
E
C
G
LS-B7L-1
B7L-2C
B7L-1C
323532353235
2223222322232223
1 14
2220164
9152325
29 31
57 3 1
4 425
12 10 8 6
21 1
11 9
13 7
7 13
36 39
CR-B7L-2/4 CR-B7L-2/6 CR-B7L-2/6 CR-B7L-2/6 CR-B7L-2/8 CR-B7L-2/8 CR-B7L-2/8
CR-B7L-2/10
84" 84"
84"
94" 84"
94"
84" 84" 84"
84"
78"66"
66"78"
66" 78"
66"78"
66"78"
66" 78"
84"
66"
20" 20" 20"
14 14 84"66"
NORTH
KEY PLAN - B-WING AREA A
B
A
PROVIDE RECEPTACLES IN SYSTEM FURNITURE. VERIFY
REQUIREMENTS WITH MANUFACTURER.
PROVIDE WIREMOLD IN EQUIPMENT STORAGE.
INSTALL CABLE REEL IN CEILING. COORDINATE EXACT
LOCATIONS WITH OWNER.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT OF RECORD
A/E:
STAMPCONSULTANTS
o n e e ig h th in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s in c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h e s o n e f o o t th re e in c h e s o n e f o o t
A
2 3 4 5 6
B
C
D
1 2 3 4 5 6
A
B
C
D
FOR OFFICIAL USE ONLY
MECHANICAL / ELECTRICAL / PLUMBING: STRUCTURAL:HEALTHCARE ARCHITECT:
2550 UNIVERSITY AVE. W. SUITE 423-S
ST. PAUL, MN 55114
651.251.7570
50 SOUTH 6TH ST UNIT 1100
MINNEAPOLIS, MN 55402
612.465.7550
380 ST. PETER ST. UNIT 600
ST. PAUL, MN 55102
651.222.3701
C U s e rs
\b e n z \D o c u m e n ts \2
M
D I n
P a t
B
E
B e n .Z u rn
.r v t
/1
/2
:5
:1
P
M
EP171
7TH LEVEL - POWER PLAN AREA A
Stone Group Architects
600 E 7th Street
Sioux Falls, SD 57103
605-271-1144
VA Madison Renovate Inpatient Ward
7B
2500 Overlook Terrace, Madison, WI 53705
05/17/2024 JK BZ
100% CONSTRUCTION
DOCUMENTS
SGA #231919
VA #607-22-101
1/4" = 1'-0"
LEVEL 7 AREA A - POWER PLAN
J
J
J
J
J
J
J J
J
J
J
J
J J J J J J
JJ
JJ
KEY NOTES:
ISO PATIENT RM
B7074A
ISO PATIENT RM
B7076A
PATIENT RM
B7070
PATIENT RM
B7068
PATIENT RM
B7064
ISO PATIENT RM
B7062A
ISO PATIENT RM
B7063A
EPI/BARI
PATIENT RM
B7065
BARI PATIENT
RM
B7069
PATIENT RM
B7071
PAT TLT
B7074B
PAT TLT
B7070A
PAT TLT
B7064A
PAT TLT
B7068A
PAT TLT
B7062B
PAT TLT
B7063B
PAT TLT
B7065A
PAT TLT
B7069A
PAT TLT
B7071A
ANTE
B7074
ANTE
B7076
ANTE
B7062
ANTE
B7063
NURSE
MANAGER
B7077
ASSIST NURSE
MANGER
B7060
SOILED UTILITY
B7073
MEDS
B7081A
MEDS ALCOVE
B7121B
NURSE ALCOVE
B7121A
HSKPG
B7059
PT TREATMENT
B7061
ELEC
B7121D
EQUIP.
B7121C
18 19 20 21 22
D
E
C
G
CR-B7L-1
CR-B7L-2
B7L-1E
13 19
20 35
203535
37 2 2
313724
12 18
37 37
41 41 3
35 9
29 15
8 23
14 29
LS-B7L-1/3
CR-B7L-2/19
CR-B7L-2/19
CR-B7L-2/19
CR-B7L-2/19
CR-B7L-2/21
CR-B7L-2/21
CR-B7L-2/21CR-B7L-2/21
CR-B7L-2/2
CR-B7L-2/2
CR-B7L-2/2 CR-B7L-2/2 CR-B7L-2/4 CR-B7L-2/4
CR-B7L-2/10CR-B7L-2/10CR-B7L-2/12
CR-B7L-2/12
84" 84" 84" 84" 84"
84"
84" 84"
84" 84"
94"
CR-B7L-2/17
NORTH
KEY PLAN - B-WING AREA B
B
A
DEDICATED CRITICAL POWER CONNECTION TO PNEUMATIC
TUBE STATION.
INSTALL 1/2"C. FROM THE POWERED DOOR PUSH BUTTONS
TO THE POWERED DOOR CONTROL BOX FOR ROUTING OF
CONTROL WIRES. FOLLOW MANUFACTURER GUIDELINES
FOR PLACEMENT OF POWERED DOOR POWER SUPPLY.
INSTALL DISCONNECT TOGGLE SWITCH WITHIN 36" OF THE
CONNECTION POINT. SEE ARCH FOR EXACT DOOR
OPERATOR POSITIONS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT OF RECORD
A/E:
STAMPCONSULTANTS
o n e e ig h th in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s in c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h e s o n e f o o t th re e in c h e s o n e f o o t
A
2 3 4 5 6
B
C
D
1 2 3 4 5 6
A
B
C
D
FOR OFFICIAL USE ONLY
MECHANICAL / ELECTRICAL / PLUMBING: STRUCTURAL:HEALTHCARE ARCHITECT:
2550 UNIVERSITY AVE. W. SUITE 423-S
ST. PAUL, MN 55114
651.251.7570
50 SOUTH 6TH ST UNIT 1100
MINNEAPOLIS, MN 55402
612.465.7550
380 ST. PETER ST. UNIT 600
ST. PAUL, MN 55102
651.222.3701
C U s e rs
\b e n z \D o c u m e n ts \2
M
D I n
P a t
B
E
B e n .Z u rn
.r v t
/1
/2
:5
:2
P
M
EP172
7TH LEVEL - POWER PLAN AREA B
Stone Group Architects
600 E 7th Street
Sioux Falls, SD 57103
605-271-1144
VA Madison Renovate Inpatient Ward
7B
2500 Overlook Terrace, Madison, WI 53705
05/17/2024 JK BZ
100% CONSTRUCTION
DOCUMENTS
SGA #231919
VA #607-22-101
1/4" = 1'-0"
LEVEL 7 AREA B - POWER PLAN
J J J
J J
J
KEY NOTES:
18 19 20 21 22 23 24 25 26 27 28 29
D
E
C
G
1 2
RL
RL
RL
RL
1 REWORK 3/4" CONDUIT TO EXISTING JUNCTION BOX.
JUNCTION BOX LOCATED ABOVE 2X2 GRID CEILING.
RELOCATE RECEPTACLE OUT OF RATED SHAFT.
NORTH
KEY PLAN - B-WING OVERALL
B
A
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT OF RECORD
A/E:
STAMPCONSULTANTS
o n e e ig h th in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s in c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h e s o n e f o o t th re e in c h e s o n e f o o t
A
2 3 4 5 6
B
C
D
1 2 3 4 5 6
A
B
C
D
FOR OFFICIAL USE ONLY
MECHANICAL / ELECTRICAL / PLUMBING: STRUCTURAL:HEALTHCARE ARCHITECT:
2550 UNIVERSITY AVE. W. SUITE 423-S
ST. PAUL, MN 55114
651.251.7570
50 SOUTH 6TH ST UNIT 1100
MINNEAPOLIS, MN 55402
612.465.7550
380 ST. PETER ST. UNIT 600
ST. PAUL, MN 55102
651.222.3701
C U s e rs
\b e n z \D o c u m e n ts \2
M
D I n
P a t
B
E
B e n .Z u rn
.r v t
/1
/2
:5
:2
P
M
EP181
LEVEL 8 - ELECTRICAL POWER PLAN
Stone Group Architects
600 E 7th Street
Sioux Falls, SD 57103
605-271-1144
VA Madison Renovate Inpatient Ward
7B
2500 Overlook Terrace, Madison, WI 53705
05/17/2024 JK BZ
100% CONSTRUCTION
DOCUMENTS
SGA #231919
VA #607-22-101
1/8" = 1'-0"
LEVEL 8 - ELECTRICAL PLAN
F E
S F
S F
S F
S F
KEY NOTES:
FE
AHURF
7B
HP
9B01
HP
9B02
18 19 20 21 22 23 24 25 26 27 28 29
D
E
C
GLP LP LP
LP
LP
LP
LPLP
LP
LP
LP
LP
LPLPLP
LP
LP
LP
LP
LPLP
LP
LP
LP
AHUSF
7B
SUH
9B5
EF
7B01
EF
7B02A
SUH
9B6
SUH
9B7
EF
7B03
NL
GFS
EF
7B02B
BPHE/4B1
SCP
9B01
1 11
1 1 1
LP
LP
LP
LP
1 BOND NEW LIGHTNING PROTECTION TO EXISTING LIGHTNING
PROTECTION SYSTEM
NURSE CALL ROUTES TO PENTHOUSE TELECOM ROOM. SEE 7TH
FLOOR FOR DEVICES.
D.A
C.A
E.A g.A
D
E
C
G
BPHE-1
BPHE/1B
BPHE/2B
NORTH
KEY PLAN - B-WING OVERALL
B
A
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT OF RECORD
A/E:
STAMPCONSULTANTS
o n e e ig h th in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s in c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h e s o n e f o o t th re e in c h e s o n e f o o t
A
2 3 4 5 6
B
C
D
1 2 3 4 5 6
A
B
C
D
FOR OFFICIAL USE ONLY
MECHANICAL / ELECTRICAL / PLUMBING: STRUCTURAL:HEALTHCARE ARCHITECT:
2550 UNIVERSITY AVE. W. SUITE 423-S
ST. PAUL, MN 55114
651.251.7570
50 SOUTH 6TH ST UNIT 1100
MINNEAPOLIS, MN 55402
612.465.7550
380 ST. PETER ST. UNIT 600
ST. PAUL, MN 55102
651.222.3701
C U s e rs
\b e n z \D o c u m e n ts \2
M
D I n
P a t
B
E
B e n .Z u rn
.r v t
/1
/2
:5
:2
P
M
EP191
PENTHOUSE/ROOF - ELECTRICAL
POWER PLANStone Group Architects
600 E 7th Street
Sioux Falls, SD 57103
605-271-1144
VA Madison Renovate Inpatient Ward
7B
2500 Overlook Terrace, Madison, WI 53705
05/17/2024 JK BZ
100% CONSTRUCTION
DOCUMENTS
SGA #231919
VA #607-22-101
1/8" = 1'-0"
PENTHOUSE - POWER/SYSTEMS PLAN
1/8" = 1'-0"
PENTHOUSE PLAN A WING
S
S
F
F
F
F
F
IC
IC
IC
IC
N N
N N
N N
N N
N N
N N
N N
N N
M M
F S
FF
S
F
F S
N N N N N N N
N
FSSSSSS
S
N
N
N
N
N
N
N
N
N
N
N
N
N
N
NN
N
N
N
F
KEY NOTES:
EQUIP.
STORAGE
B7095
PATIENT RM
B7098
PATIENT RM
B7094
PATIENT RM
B7092
PATIENT RM
B7080
EPI PATIENT RM
B7086
PATIENT RM
B7082
EPI PATIENT RM
B7088
PATIENT RM
B7089
PAT TLT
B7098A
PAT TLT
B7094A
PAT TLT
B7088A
PAT TLT
B7092A
PAT TLT
B7086A
PAT TLT
B7082A
PAT TLT
B7076B
PAT TLT
B7080A
PAT TLT
B7089A
STAFF TLT
B7097
LOCKER
B7099A
BREAK / CONF
B7099
MEDS ALCOVE
B7121J
NURSE ALCOVE
B7121H
NURSE ALCOVE
B7121G
NOURISH
B7085
NURSE STATION
B7081
CORRIDOR
B7121
CLEAN LINEN
B7091
CLEAN UTILITY
B7087
CONSULT
B7081B
SHARED
EPI/PM&R
B7093
CRASH CART
B7121E
ELEC
B7121F
EQUIP.
B7121I
23 24 25 26 27 28 29
D
E
C
G
CR
CR/KP
BD
C/SA
BD
C/SA
BD
C/SA
BD
C/SA
BD
C/SA
BD
C/SA
BD
C/SA
C/SA
BD
P P P P P P P
P
P P P CM
NL
NL
NL
NL2
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
2 2
2 2 2 2
3 2 2
W
2 2
2M
2 2 84"66"
42" W
66"
42"
20" 20"
6" H 12" W
8' - 2" AFF
NORTH
KEY PLAN - B-WING AREA A
B
A
FIRE ALARM STROBE KEPT UNDER 2 HERTZ FOR EPILEPSY
SENSITIVITY.
INSTALL EPILEPSY CAMERA AND INFRARED ILLUMINATOR.
PROVIDE EZ-PATH 44+ SERIES ABOVE IT ROOM DOORS.
PROVIDE CONDUIT TO CABLE TRAY.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT OF RECORD
A/E:
STAMPCONSULTANTS
o n e e ig h th in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s in c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h e s o n e f o o t th re e in c h e s o n e f o o t
A
2 3 4 5 6
B
C
D
1 2 3 4 5 6
A
B
C
D
FOR OFFICIAL USE ONLY
MECHANICAL / ELECTRICAL / PLUMBING: STRUCTURAL:HEALTHCARE ARCHITECT:
2550 UNIVERSITY AVE. W. SUITE 423-S
ST. PAUL, MN 55114
651.251.7570
50 SOUTH 6TH ST UNIT 1100
MINNEAPOLIS, MN 55402
612.465.7550
380 ST. PETER ST. UNIT 600
ST. PAUL, MN 55102
651.222.3701
C U s e rs
\b e n z \D o c u m e n ts \2
M
D I n
P a t
B
E
B e n .Z u rn
.r v t
/1
/2
:5
:3
P
M
EY171
7TH LEVEL - SYSTEMS PLAN AREA A
Stone Group Architects
600 E 7th Street
Sioux Falls, SD 57103
605-271-1144
VA Madison Renovate Inpatient Ward
7B
2500 Overlook Terrace, Madison, WI 53705
05/17/2024 JK BZ
100% CONSTRUCTION
DOCUMENTS
SGA #231919
VA #607-22-101
1/4" = 1'-0"
LEVEL 7 AREA A - SYSTEMS PLAN
N
N
N
N N
S
S
F
FFF
N
N N
N N
N N
N N
N N
N N
N N
N N
N
NM
FF
S
FF
S
F
N N N N N N
N
N N
N
F SSSS
S
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
S
S F
KEY NOTES:
ISO PATIENT RM
B7074A
ISO PATIENT RM
B7076A
PATIENT RM
B7070
PATIENT RM
B7068
PATIENT RM
B7064
ISO PATIENT RM
B7062A
ISO PATIENT RM
B7063A
EPI/BARI
PATIENT RM
B7065
BARI PATIENT
RM
B7069
PATIENT RM
B7071
PAT TLT
B7076B
PAT TLT
B7074B
PAT TLT
B7070A
PAT TLT
B7064A
PAT TLT
B7068A
PAT TLT
B7062B
PAT TLT
B7063B
PAT TLT
B7065A
PAT TLT
B7069A
PAT TLT
B7071A
ANTE
B7074
ANTE
B7076
ANTE
B7062
ANTE
B7063
NURSE
MANAGER
B7077
ASSIST NURSE
MANGER
B7060
SOILED UTILITY
B7073
MEDS
B7081A
MEDS ALCOVE
B7121B
NURSE ALCOVE
B7121A
HSKPG
B7059
PT TREATMENT
B7061
ELEC
B7121D
EQUIP.
B7121C
18 19 20 21 22
D
E
C
G
CR
CR
E
E
BD
C/SA
P
BD
C/SA
BD
C/SA
BD
C/SA
BD
C/SA
BD
C/SA
C/SA
BD
C/SA
BD C/SA
BD
C/SA
BD
P P P P P P
P
P P
P
CM P P P
NL
NL
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
2 2 2
2 2
2 2
IC
CR
6" H 12" W
8' - 2" AFF
1 1
NORTH
KEY PLAN - B-WING AREA B
B
A
FIRE ALARM STROBE KEPT UNDER 2 HERTZ FOR EPILEPSY
SENSITIVITY.
INSTALL EPILEPSY CAMERA AND INFRARED ILLUMINATOR.
REPORT TO NURSE CALL MASTER STATION.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT OF RECORD
A/E:
STAMPCONSULTANTS
o n e e ig h th in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s in c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h e s o n e f o o t th re e in c h e s o n e f o o t
A
2 3 4 5 6
B
C
D
1 2 3 4 5 6
A
B
C
D
FOR OFFICIAL USE ONLY
MECHANICAL / ELECTRICAL / PLUMBING: STRUCTURAL:HEALTHCARE ARCHITECT:
2550 UNIVERSITY AVE. W. SUITE 423-S
ST. PAUL, MN 55114
651.251.7570
50 SOUTH 6TH ST UNIT 1100
MINNEAPOLIS, MN 55402
612.465.7550
380 ST. PETER ST. UNIT 600
ST. PAUL, MN 55102
651.222.3701
C U s e rs
\b e n z \D o c u m e n ts \2
M
D I n
P a t
B
E
B e n .Z u rn
.r v t
/1
/2
:5
:4
P
M
EY172
7TH LEVEL - SYSTEMS PLAN AREA B
Stone Group Architects
600 E 7th Street
Sioux Falls, SD 57103
605-271-1144
VA Madison Renovate Inpatient Ward
7B
2500 Overlook Terrace, Madison, WI 53705
05/17/2024 JK BZ
100% CONSTRUCTION
DOCUMENTS
SGA #231919
VA #607-22-101
1/4" = 1'-0"
LEVEL 7 AREA B - SYSTEMS PLAN
120/208V, 3Ø, 4W 800A
CR-1
A
T
A
T
A
T
A
T
A
T
A
T
A
T
A
T
A
T
A
T
A
T
A
T
A
T 120/208V, 3Ø, 4W 1600A
SWBD #4
A
T
A
T
A
T
A
T
A
T
A
T
A
T
A
T
A
T
A
T
-3
CR-B7L-2CR-B7L-1 B7L-2CB7L-1CB7L-1E
B6L-1E
120/208V, 3Ø, 4W 800A
CR-1
A
T
A
T
A
T
A
T
A
T
A
T
A
T
A
T
A
T
A
T
A
T
A
T
A
T 120/208V, 3Ø, 4W 1600A
SWBD #4
A
T
A
T
A
T
A
T
A
T
A
T
A
T
A
T
A
T
A
T
-3
120/208V 3Ø, 4W
200A MLO
CR-B7L-2
10 kAIC
120/208V 3Ø, 4W
200A MCB
CR-B7L-1
10 kAIC
120/208V 3Ø, 4W
200A MLO
B7L-2C
10 kAIC
120/208V 3Ø, 4W
200A MCB
B7L-1C
10 kAIC
120/208V 3Ø, 4W
200A MCB
B7L-1E
10 kAIC
B6L-1E
-3 2
-3
-3
120/208V 3Ø, 4W
60A MCB
LS-B7L-1
10 kAIC
LS-B7L-1
-3
5TH LEVEL
BASEMENT LEVEL
6TH LEVEL
7TH LEVEL
8TH LEVEL
PULLBOX PULLBOX
5TH LEVEL
BASEMENT LEVEL
6TH LEVEL
7TH LEVEL
8TH LEVEL
PENTHOUSE
PULLBOX PULLBOX PULLBOX
INTERCEPT EXISTING FEEDER AND
PROVIDE PULLBOX. PROVIDE CONDUIT,
CONDUCTORS, AND ACCESSORIES AND
EXTEND EXISTING FEEDER TO CR-B7L-1
PROVIDE CONDUIT, CONDUCTORS, AND ACCESSORIES
AND EXTEND EXISTING FEEDER TO PANELBOARDS
FROM EXISTING PULLBOXES.
PULLBOX
INTERCEPT EXISTING FEEDER AND
PROVIDE PULLBOX. PROVIDE CONDUIT,
CONDUCTORS, AND ACCESSORIES AND
EXTEND EXISTING FEEDER TO LS-B7L-1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT OF RECORD
A/E:
STAMPCONSULTANTS
o n e e ig h th in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s in c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h e s o n e f o o t th re e in c h e s o n e f o o t
A
2 3 4 5 6
B
C
D
1 2 3 4 5 6
A
B
C
D
FOR OFFICIAL USE ONLY
MECHANICAL / ELECTRICAL / PLUMBING: STRUCTURAL:HEALTHCARE ARCHITECT:
2550 UNIVERSITY AVE. W. SUITE 423-S
ST. PAUL, MN 55114
651.251.7570
50 SOUTH 6TH ST UNIT 1100
MINNEAPOLIS, MN 55402
612.465.7550
380 ST. PETER ST. UNIT 600
ST. PAUL, MN 55102
651.222.3701
C U s e rs
\b e n z \D o c u m e n ts \2
M
D I n
P a t
B
E
B e n .Z u rn
.r v t
/1
/2
:4
:4
P
M
EE300
ELECTRICAL RISER
Stone Group Architects
600 E 7th Street
Sioux Falls, SD 57103
605-271-1144
VA Madison Renovate Inpatient Ward
7B
2500 Overlook Terrace, Madison, WI 53705
05/17/2024 JK BZ
100% CONSTRUCTION
DOCUMENTS
SGA #231919
VA #607-22-101
12" = 1'-0"
PARTIAL DEMOLITION ELECTRICAL RISER
12" = 1'-0"
PARTIAL ELECTRICAL RISER
FEEDER SCHEDULE
NOTES:
GENERAL NOTES:
A. NOMENCLATURE DEFAULTS WITH A SINGLE NEUTRAL AND A
GROUND.
T THREE WIRE ONLY, NO NEUTRAL
N ADDED NEUTRAL
L ALUMINUM
U UNDERGROUND
P PVC
D SIZED FOR VOLTAGE DROP
S SERVICE SECONDARY
-3 THREE PHASE
-2 SINGLE PHASE
XXXX
FEEDER FEEDER DESCRIPTION CONDUIT
60-3 1"C, 4#6 + #10 G EMT
200-3 2"C, 4#3/0 + #6 G EMT
EXISTING EIGHTH FLOOR
TAMPER
SWITCH
FLOW
SWITCH
EXIST
FACP
TO EXISTING OVERHEAD
PAGING SYSTEM
7TH FLOOR
TYP
CMF CMF CMF CMF CMF CMF
F FF F s F s F
#/E
CM
ACCESS CTRL RELEASE
TYP
TO ADDITIONAL
SMOKE,
FIRE/SMOKE
DAMPERS
ES
EL
ML
P
R
H
DD
P H
MM MM
RL
#/C #/C
#/C
#/C
F F
F F
F F
FF
P
MC
HF F
F F
F SS
S
F F
F
FF
#/A
#/B
2C
TO ADDITIONAL
DOOR HOLDERS
DHDH
#/C
#/B
2C
F F
KEY NOTES
SEE SPECIFICATIONS FOR BACKGROUND MUSIC AND
PAGING ZONE SCHEDULE.
FIRE/SMOKE AND SMOKE DAMPER MOTORS ARE
SHOWN ON MECHANICAL PLANS. VERIFY QUANTITIES
AND LOCATIONS. PROVIDE FIRE ALARM CONNECTIONS
TO RELAY SO THAT THE FIRE/SMOKE AND SMOKE
DAMPERS CLOSE UPON LOSS OF POWER. (DIV. 26
SHALL PROVIDE RELAY AND CIRCUITING. SEE POWER
PLANS FOR 120V CIRCUITING, RELAY LOCATIONS, ETC.)
PROVIDE ONE (1) FIRE ALARM CONTROL MODULE PER
FIRE/SMOKE DAMPER AND (1) ADDITIONAL FIRE ALARM
CONTROL MODULE PER SMOKE ZONE FOR
INTEGRATION WITH SMOKE EVACUATION SEQUENCE
OF OPERATIONS. SEE ARCH. LIFE SAFETY PLANS FOR
SMOKE ZONES.
1. THE WIRING DIAGRAM IS CONCEPTUAL ONLY AND
DOES NOT INDICATE ALL DEVICES, DEVICE TYPES
OR QUANTITY OF LOOPS. REFER TO FLOOR PLANS
FOR DEVICE QUANTITIES AND LOCATIONS.
2. THE SYSTEM DIAGRAM IS BASED ON A DIGITAL,
ADDRESSABLE FIRE ALARM SYSTEM.
3. ALL WIRING AND CABLING SHALL BE IN CONDUIT
(MINIMUM 3/4" C.) EMT CONDUIT USED FOR FIRE
ALARM WIRING SHALL INCLUDE FACTORY-APPLIED
RED TOPCOAT UL-LISTED FOR FIRE ALARM USE.
4. THE INSTALLATION SHALL BE FROM DRAWINGS
THAT HAVE BEEN SUBMITTED, REVIEWED AND
APPROVED BY THE AUTHORITIES HAVING
JURISDICTION.
5. EACH SIGNALING CIRCUIT SHALL ALLOW 15%
SPARE CAPACITY TO ADD ADDITIONAL AUDIO,
VISUAL OR COMBINATION AUDIO/VISUAL SIGNALING
DEVICES TO ANY OF THESE CIRCUITS.
6. PROVIDE THE CONTROL WIRING FROM FIRE ALARM
CONTROLLER TO THE HVAC CONTROLLER.
7. REFER TO FIRE ALARM CONTROL MATRIX FOR ALL
CONTROL REQUIREMENTS.
CABLE TYPE
#/A CABLE TYPE CALLOUT
CABLE QUANTITIES
INITIATING LINE CIRCUIT#/A
#/B
#/C
#/D
#/E
#/F
#/G
#/H
GENERAL NOTES
/# J
BRANCH CIRCUIT
CONTROL CIRCUIT
FIBER OPTIC CONNECTION
SIGNAL LINE CIRCUIT
TWO-HOUR RATED PRIMARY BACKBONE (CLASS A)
TWO-HOUR RATED REDUNDANT BACKBONE (CLASS A)
FUTURE FIRE FIGHTERS TELEPHONE HOMERUN
AUDIO INPUT
TO BACKGROUND MUSIC
AND PAGING ZONES
EXIST
VOICE
EVAC
TAMPER
SWITCH
FLOW
SWITCH
TYP
CMF CMF CMF CMF CMF CMF
F FF F s F s F
#/E
CM
ACCESS CTRL RELEASE
TYP
TO ADDITIONAL
SMOKE,
FIRE/SMOKE
DAMPERS
ES
EL
ML
P
R
H
DD
P H
MM MM
RL
#/C #/C
#/C
#/C
F F
F F
F F
FF
P
MC
HF F
F F
F SS
S
F F
F
FF
#/A
#/B
2C
TO ADDITIONAL
DOOR HOLDERS
DHDH
#/C
#/B
2C
F F
EXIST
FACP
EXIST
VOICE
EVAC
EXISTING PENTHOUSE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT OF RECORD
A/E:
STAMPCONSULTANT…
This is the start of the file's text. The full file is on GovTribe.