S02 - Drawings Vol 1 of 4.pdf

PDF 19 MB Posted

Attached to
Z1DA--607-22-101 Renovate Inpatient Ward 7B (VA-25-00007172)
Solicitation number
36C25224B0016
Issued by

About this file

The provided document appears to be a set of drawings titled "S02 - Drawings Vol 1 of 4" related to the federal contract opportunity "Z1DA--607-22-101 Renovate Inpatient Ward 7B (VA-25-00007172)." The contract opportunity is a solicitation issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12 to renovate Inpatient Ward 7B. The document does not appear to contain details on the required products or services, response dates, award dates, pricing terms, set asides, or other key information. Rather, it appears to be a technical drawing package that is likely part of the full solicitation documents.

View the file

Other files

File Type Posted
S06 - Updated Drawings - 0003.pdf PDF
36C25224B0016 0003.docx DOCX document
S06 - Updated Spec Sections - 0003.pdf PDF
S06 - Drawing AC020204 - 0003.pdf PDF
36C25224B0016 0002.docx DOCX document
S06 - SF1442 Page 1 - Revised.pdf PDF
S06 - Wage Determination Revised.pdf PDF
36C25224B0016 0001.docx DOCX document
S04 - Pre-Bid Attendance List.pdf PDF
36C25224B0016.docx DOCX document
S02 - Specs Vol 2 of 3.pdf PDF
S02 - Specs Vol 1 of 3.pdf PDF
S02 - Drawings Vol 2 of 4.pdf PDF
S02 - Specs Vol 3 of 3.pdf PDF
S02 - Drawings Vol 3 of 4.pdf PDF
S02 - Drawings Vol 4 of 4.pdf PDF
Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VICINITY MAP

PROJECT LOCATION

SYMBOLS & ANNOTATION LEGEND:

TYPICAL DIMENSION LINE

BREAK LINE

DETAIL INDICATORXX

X-XXX

DETAIL INDICATORXX

X-XXX

XX WALL SECTION INDICATOR

X

X-XXX XX X-XXX EXTERIOR ELEVATION INDICATOR

ELEVATION / LEVEL INDICATOR

CENTER LINE

INTERIOR ELEVATION INDICATORX-XXX

XX

X-XXX

XX

XX

XX

XX

NORTH ARROW(S)

CG

CORNER GUARD

FEC FIRE EXTINGUISHER CABINET

X.X KEYNOTE

X NEW GRID LINE

XXX

ROOM

XXX FINISH INDICATOR

XXX

XX

DRAWING TITLE

X"=X'-X"

XX

TRUE

NORTH

PLAN

NORTH

XX

X-XXX

BUILDING SECTION INDICATOR

XX

X-XXX

DETAIL INDICATOR

X-XXX

NORTH

EXISTING GRID LINEX

XX / XXX

SPOT ELEVATION INDICATOR

LEVEL TITLE

TYPICAL DRAWING BLOCK TITLE

DRAWING REFERENCE

X'-X"

ELEVATION / LEVEL INDICATOR

LEVEL TITLE

X'-X"

X' X"

D R

A W

IN

G

R E

F E

R E

N C

E S

P

D F

L

IN

K S

SPOT COORDINATE INDICATOR

X'-X"

CR

X'-X" / X'-X"

SLOPE INDICATOR

X

XX

XX

REVISION / ISSUE INDICATOR

CARD READER

ROOF TYPE INDICATOR

WINDOW / STOREFRONT TYPE INDICATOR

PARTITION TYPE

DOOR / OPENING INDICATOR

(BORROWED LIGHT INCLUDED)

ROOM INDICATOR

EQUIPMENT INDICATOR

TYPE X

X'-X" A.F.F.

CEILING TYPE INDICATOR

XXX

A R

C H

IN

T M

A T

E R

IA

L

L E

G E

N D

BATT INSULATION

WOOD ROUGH (CONTINUOUS)

WOOD ROUGH (SPACED)

EXISTING CONSTRUCTION

TO BE REMOVED

NEW CONSTRUCTION

EARTH

EARTH (UNDISTURBED)

GYPSUM BOARD

CONCRETE

RIGID INSULATION

PLYWOOD

GRANULAR FILL

ASPHALT

ALUMINUM

STEEL

WOOD

BRICK

BLOCK

STONE

FIREPROOFING

LOOSE INSULATION

SAND

EXISTING CONSTRUCTION

TO REMAIN

SPRAY INSULATION

VINYL

EPOXY

ABBREVIATIONS

SYMBOLS

# POUND OR NUMBER

& AND

< ANGLE

<< DOUBLE ANGLE

@ AT

d PENNEY

Ø ROUND OR DIAMETER

A

A/E ARCHITECT/ENGINEER

AB ANCHOR BOLT

ABV ABOVE

AC ASPHALTIC CONCRETE/AIR CONDITIONER

ACC ACCESSIBLE

ACM ALUMINUM COMPOSITE MATERIAL

ACOUS ACOUSTICAL

ACT ACOUSTICAL CEILING TILE

AD AREA DRAIN

ADA AMERICANS WITH DISABILITIES ACT

ADD ADDENDUM

ADH ADHESIVE

ADJ ADJUSTABLE, ADJACENT, ADJOINING

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AHJ AUTHORITY HAVING JURISDICTION

ALT ALTERNATIVE

ALUM ALUMINUM

ANSI AMERICAN NATIONAL STANDARDS INSTITUTE

APC ACOUSTICAL PANEL CEILING

APPROX APPROXIMATE

ARCH ARCHITECT (URAL)

ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS

B

BD BOARD

BEV BEVELED

BFF BELOW FINISH FLOOR

BL BRICK LEDGE

BLDG BUILDING

BLKG BLOCK (ING)

BM BEAM

BO BOTTOM OF

BOC BOTTOM OF CONCRETE

BOF BOTTOM OF FOOTING

BOT BOTTOM

BRG BEARING

BRK BRICK

BRKT BRACKET

BSMT BASEMENT

BTWN BETWEEN

BUR BUILT UP ROOFING

C

C CHANNEL/CELSIUS

CAB CABINET

CB CERAMIC BASE

CCW COUNTER CLOCKWISE

CD CONSTRUCTION DOCUMENTS

ABBREVIATIONS

CEM CEMENT

CF CUBIC FEET OR FOOT

CG CORNER GUARD

CH CHANNEL

CIPC CAST-IN-PLACE CONCRETE

CJ CONTROL/CONSTRUCTION JOINT

CL CENTER LINE

CLKG CAULKING

CLR CLEAR, CLEARANCE

CMU CONCRETE MASONRY UNIT

CO CHANGE ORDER/CLEANOUT

COL COLUMN

COMB COMBINATION

COMP COMPOSITE/COMPOSITION

CONC CONCRETE

CONN CONNECT (ION)

CONST CONSTRUCTION

CONT CONTINUOUS, CONTINUE

CONTR CONTRACT (OR)

COORD COORDINATE

CORR CORRUGATED/CORRIDOR

CPPT CARPET TILE

CPT CARPET

CSMT CASEMENT

CT CERAMIC TILE

CTB CARPET TILE BASE

CTR CENTER

D

D DEPTH

DBL DOUBLE

DEMO DEMOLITION, DEMOLISH

DEPT DEPARTMENT

DET DETAIL

DF DRINKING FOUNTAIN

DIA DIAMETER

DIAG DIAGONAL

DIM DIMENSION

DISP DISPENSER

DN DOWN

DR DOOR

DS DOWNSPOUT

DW DISHWASHER

DWG DRAWING (S)

DWR DRAWER

DWTR DUMBWAITER

E

(E) EXISTING

E EAST

EA EACH

EF EACH FACE

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRICAL

ELVR ELEVATOR

EMER EMERGENCY

ENGR ENGINEER

ENL ENLARGED

ABBREVIATIONS

EOP EDGE OF PAVEMENT

EPDM ETHYLENE PROPYLENE DIENE TERPOLYMER

MEMBRANE

EPS EXPANDED POLYSTYRENE BOARD

EPT EPOXY PAINT

EQ EQUAL

EQUIP EQUIPMENT

ES EACH SIDE

EST ESTIMATE

ETC ETCETERA

ETR EXISTING TO REMAIN

EW EACH WAY

EWC ELECTRIC WATER COOLER

EXC EXCAVATE/EXCAVATION

EXH EXHAUST

EXIST EXISTING

EXP EXPANSION/EXPOSED

EXT EXTERIOR

F

FA FIRE ALARM

FAB FABRICATE/FABRICATION

FD FLOOR DRAIN

FDC FIRE DEPARTMENT CONNECTION

FDTN FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FF FINISHED FLOOR

FFE FINISHED FLOOR ELEVATION

FIN FINISH (ED)

FLR FLOOR (ING)

FLUOR FLUORESCENT

FO FACE OF

FOC FACE OF CONCRETE

FOF FACE OF FINISH

FOM FACE OF MASONRY

FOS FACE OF STUD

FR FIRE RESISTANT/FRAME

FRP FIBERGLASS REINFORCED PANEL

FS FLOOR SINK

FT FOOR, FEET/FIRE TREATED

FTG FOOTING

FURN FURNISH

FUT FUTURE

G

GA GAGE, GAUGE

GALV GALVANIZED

GB GRAB BAR

GC GENERAL CONTRACTOR

GI GALVANIZED IRON

GL GLASS

GLU LAM GLUE LAMINATED (BEAM)

GWB GYPSUM WALL BOARD

GYP BD GYPSUM

H

HB HOSE BIB

HC HANDICAP / HOLLOW CORE

ABBREVIATIONS

HD HEAVY DUTY

HDBD HARDBOARD

HDR HEADER

HM HOLLOW METAL

HORZ HORIZONTAL

HR HOUR

HT HEIGHT

HVAC HEATING, VENTILATION, AIRCONDITIONING

I

IBC INTERNATIONAL BUILDING CODE

ICC INTERNATIONAL CODE COUNCIL

ID INSIDE DIAMETER/DIMENSION

IFC INTERNATIONAL FIRE CODE

IN INCH (ES)

INCL INCLUDE (D), INCLUDING

INFO INFORMATION

INSP INSPECTION

INSTR INSTRUCTION (S)

INSUL INSULATE (D), INSULATION

INT INTERIOR

J

JAN JANITOR

JST JOIST

JT JOINT

K

KCJ KEYED CONSTRUCTION JOINT

KO KNOCK OUT

L

L LENGHT / ANGLE

LAB LABORATORY

LAM LAMINATE (D)

LAV LAVATORY

LB POUND

LF LINEAR FEET

LH LEFT HAND

LKR LOCKER

LOC LOCATION

LONG LONGITUDINAL

LT LIGHT

LVR LOUVER

LVT LUXURY VINYL TILE

M

MAS MASONRY

MATL MATERIAL

MAX MAXIMUM

MC MEDICINE CABINET

MECH MECHANICAL

MEMB MEMBRANE

MEZZ MEZZANINE

MFR MANUFACTURE (R)

MIN MINIMUM

MISC MISCELLANEOUS

MNTG MOUNTING

MO MASONRY OPENING

ABBREVIATIONS

MR MIRROR

MTL METAL

N

(N) NEW

N NORTH

NA NOT APPLICABLE

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NTS NOT TO SCALE

O

OC ON CENTER

OD OUTSIDE DIAMETER

OFCI OWNER FURNISHED / CONTRACTOR

INSTALLED

OFOI OWNER FURNISHED / OWNER INSTALLED

OH OVERHEAD

OPG OPENING

OPP OPPOSITE

ORD OVERFLOW ROOF DRAIN

ORIG ORIGINAL

OZ OUNCE

P

PAR PARALLEL

PCF POUNDS PER CUBIC FOOT

PED PEDISTAL

PERF PERFORATED

PERP PERPENDICULAR

PL PLATE

PLAM PLASTIC LAMINATE

PLMG PLUMBING

PLYWD PLYWOOD

PNL PANEL

PR PAIR / PROPOSAL REQUEST

PRCST PRECAST

PREFAB PREFABRICATE

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PAINT / PRESSURE TREATED

PTD PAPER TOWEL DISPENSER

PTN PARTITION

PTR PAPER TOWEL RECEPTICAL

PVC POLYVINYL CHOLORIDE

Q

QT QUARRY TILE

R

R RADIUS / RISER

RB RUBBER BASE

RBR RUBBER

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

REBAR REINFORCING BAR

REC RECESSED

REF REFERENCE / REFRIGERATOR

ABBREVIATIONS

REINF REINFORC (D), (ING), (MENT)

REQ REQUIRE

REQD REQUIRED

RES RESILIENT FLOORING

RET RETURN

REV REVISION (S), REVISED

RFG ROOFING

RFI REQUEST FOR INFORMATION

RFP REQUEST FOR PROPOSAL

RH RIGHT HAND

RL RIDGE LINE

RM ROOM

RO ROUGH OPENING

ROW RIGHT OF WAY

RVS REVERSE (SIDE)

RWL RAIN WATER LEADER

S

S SOUTH

SB SPLASH BACK

SC SOLID CORE

SCHED SCHEDULE

SCR SHOWER CURTAIN ROD

SCT SECTION

SD SOAP DISPENSER

SF SQUARE FOOT

SHT SHEET

SHTHG SHEATHING

SIM SIMILAR

SLDG SLIDING

SLNT SEALANT

SND SANITARY NAPKIN DISPENSER

SNX SANIARY NAPKIN DISPOSAL

SOG SLAB ON GRADE

SPEC SPECIFICATION (S)

SQ SQUARE

SSM SOLID SURFACE MATERIAL

SST STAINLESS STEEL

ST STREET

STC SOUND TRANSMISSION CLASS

STD STANDARD

STL STEEL

STOR STORAGE

STRUCT STRUCTURAL

SUSP SUSPENDED

SV SHEET VINYL

SW SHEARWALL

SYM SYMMETRICAL

T

T TREAD

T&B TOP & BOTTOM

T&G TOUNGE AND GROOVE

TB TOWEL BAR

TBD TO BE DETERMINED

TEMP TEMPORARY / TEMPERED

TER TERRAZZO

TFE TOP FOOTING ELEVATION

THD THREAD (ED) (S)

ABBREVIATIONS

THK THICKNESS

THRU THROUGH

TKBD TACKBOARD

TL TILE

TO TOP OF

TOB TOP OF BEAM

TOC TOP O F CONCRETE/CURB

TOD TOP OF DECK

TOF TOP OF FOOTING (FOUNDATION)

TOJ TOP OF JOIST

TOM TOP OF MASONRY

TOP TOP OF PIER

TOS TOP OF SLAB/STEEL

TOW TOP OF WALL

TPD TOILET PAPER DISPENSER

TPO THERMOPLASTIC POLYOLEFIN

TPTN TOILET PARTITION

TRANS TRANSVERSE

TS TUBE STEEL

TYP TYPICAL

U

UG UNDERGROUND

UH UNIT HEATER

UNFIN UNFINISHED

UNO UNLESS NOTED OTHERWISE

UON UNLESS OTHERWISE NOTED

UTIL UTILITY

V

V SHEAR

VAR VARIES

VB VAPOR BARRIER

VCT VINYL COMPOSITION TILE

VERT VERTICAL

VEST VESTIBULE

VIF VERIFY IN FIELD

VR VAPOR RETARDER

VWC VINYL WALL COVERING

W

W WEST/WIDTH

W/ WITH

W//O WITHOUT

WA WEDGE ACHOR

WB WOOD BASE

WC WATER CLOSET

WD WOOD/WOODWORK

WDW WINDOW

WF (W) WIDE FLANGE

WG WALL GUARD

WH WATER HEATER

WI WROUGHT IRON

WL WIND LOAD

WP WATERPROOF (ING)

WR WATER RESISTANT

WSCT WAINSCOT

WT WEIGHT / WINDOW TREATMENT

WWF WELDED WIRE FABRIC

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ARCHITECT OF RECORD

A/E:

STAMPCONSULTANTS

o n e e ig h th in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s in c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h e s o n e f o o t th re e in c h e s o n e f o o t

MECHANICAL / ELECTRICAL / PLUMBING: STRUCTURAL:HEALTHCARE ARCHITECT:

1 2 3 4 5 6

A

B

C

D

1 2 3 4 5 6

A

B

C

D

2550 UNIVERSITY AVE. W. SUITE 423-S

ST. PAUL, MN 55114

651.251.7570

50 SOUTH 6TH ST UNIT 1100

MINNEAPOLIS, MN 55402

612.465.7550

380 ST. PETER ST. UNIT 600

ST. PAUL, MN 55102

651.222.3701

C U s e rs

\T .L a rs o n \D o c u m e n ts

\2

M D

I n

P a t

B T a n n e rL

N

S

C .r v t

/1

/2

:5

:4

A

M

GI000

COVER SHEET

Stone Group Architects

600 E 7th Street

Sioux Falls, SD 57103

605-271-1144

RENOVATE INPATIENT WARD - 7B

2500 OVERLOOK TERRACE, MADISON, WI 53705

05/17/2024 JHK / IEP TDL

100% CONSTRUCTION

DOCUMENTS

SGA #231919

VA #607-22-101

RENOVATE INPATIENT WARD - 7B

WM. S. MIDDLETON VA HOSPITAL

DEPT OF VETERANS AFFAIRS

2500 OVERLOOK TERRACE

MADISON, WI 53705

100% CONSTRUCTION DOCUMENTS

VA PROJECT # 607-22-101

SHEET INDEX

01 - GENERAL

GI000 COVER SHEET

GI101 ACCESSIBILITY DETAILS

GI102 ACCESSIBILITY DETAILS

GI103 LIFE SAFETY CODE REVIEW

GI104 LIFE SAFETY PLANS

GI110 PHASING PLANS

HA100 7TH LEVEL HAZARDOUS MATERIAL PLAN

04 - STRUCTURAL

SE000 STRUCTURAL COVER SHEET

SE001 GENERAL STRUCTURAL NOTES

SE002 TYPICAL DETAILS - STEEL & SCHEDULES

SE107 8TH FLOOR FRAMING

SE108 PENTHOUSE FLOOR FRAMING

SE109 PENTHOUSE ROOF FRAMING PLAN

SE110 FRAMING DETAILS

SE111 FRAMING DETAILS

SE112 FRAMING ELEVATIONS

05 - ARCHITECTURAL DEMOLITION

AD101 6TH LEVEL DEMOLITION RCP - ABOVE CEILING

AD102 7TH LEVEL DEMOLITION PLAN

AD103 7TH LEVEL DEMOLITION PLAN - FLOOR PENETRATIONS

AD104 8TH LEVEL & PENTHOUSE DEMOLITION PLAN

AD110 7TH LEVEL DEMOLITION RCP

AD111 8TH LEVEL DEMOLITION RCP & ABOVE CEILING

AD120 ROOF DEMOLITION PLAN

06 - ARCHITECTURAL

AE101 7TH LEVEL FLOOR PLAN - OVERALL

AE102 7TH LEVEL FLOOR PLAN - AREA A

AE103 7TH LEVEL FLOOR PLAN - AREA B

AE104 7TH LEVEL DIMENSION PLAN - AREA A

AE105 7TH LEVEL DIMENSION PLAN - AREA B

AE106 8TH LEVEL & PENTHOUSE FLOOR PLAN

AE110 7TH LEVEL REFLECTED CEILING PLAN - AREA A

AE111 7TH LEVEL REFLECTED CEILING PLAN - AREA B

AE120 ROOF PLAN

AE201 EXTERIOR ELEVATIONS

AE301 BUILDING SECTIONS

AE310 WALL SECTIONS

AE311 WALL SECTIONS

AE501 DETAILS

AE502 DETAILS

AE503 DETAILS

AE601 SCHEDULES

SHEET INDEX

07 - INTERIORS

AI101 FINISH SCHEDULE

AI102 7TH LEVEL FINISH PLAN - AREA A

AI103 7TH LEVEL FINISH PLAN - AREA B

AI201 EQUIPMENT SCHEDULE

AI202 7TH LEVEL EQUIPMENT PLAN - AREA A

AI203 7TH LEVEL EQUIPMENT PLAN - AREA B

AI301 7TH LEVEL WALL PROTECTION PLAN - AREA A

AI302 7TH LEVEL WALL PROTECTION PLAN - AREA B

AI401 INTERIOR ELEVATIONS

AI402 INTERIOR ELEVATIONS

AI403 INTERIOR ELEVATIONS

AI404 INTERIOR ELEVATIONS

AI405 INTERIOR ELEVATIONS

AI406 INTERIOR ELEVATIONS

AI407 INTERIOR ELEVATIONS

AI501 MILLWORK SECTION DETAILS

AI502 MILLWORK SECTION DETAILS

AI601 SIGNAGE SCHEDULE & DETAILS

AI602 7TH LEVEL SIGNAGE PLAN - AREA A

AI603 7TH LEVEL SIGNAGE PLAN - AREA B

08 - MECHANICAL

M000 MECHANICAL TITLE SHEET

FPD170 LEVEL 7 - DEMOLITION FIRE PROTECTION PLAN

FP170 LEVEL 7 - FIRE PROTECTION PLAN

FP190 PENTHOUSE - FIRE PROTECTION PLAN

PPD160 LEVEL 6 - DEMOLITION PLUMBING PLAN

PPD170 LEVEL 7 - DEMOLITION PLUMBING PLAN

PPD180 LEVEL 8 - DEMOLITION PLUMBING PLAN

PPD190 PENTHOUSE AND ROOF - DEMOLITION PLUMBING PLAN

PMD170 LEVEL 7 - DEMOLITION MEDICAL GAS PLAN

PP160 LEVEL 6 - PLUMBING PLAN

PP170 LEVEL 7 - PLUMBING PLAN - OVERALL

PP171 LEVEL 7 - PLUMBING PLAN - AREA A

PP172 LEVEL 7 - PLUMBING PLAN - AREA B

PP180 LEVEL 8 - PLUMBING PLAN

PP190 PENTHOUSE AND ROOF - PLUMBING PLAN

PM170 LEVEL 7 - MEDICAL GAS PLAN

P200 PLUMBING RISER DIAGRAMS - DOMESTIC WATER

P201 PLUMBING RISER DIAGRAM - WASTE AND VENT

P202 PLUMBING RISER DIAGRAM - STORM DRAINAGE

P300 PLUMBING DETAILS

P400 PLUMBING SCHEDULES

MHD170 LEVEL 7 - DEMOLITION HVAC PLAN

MHD180 LEVEL 8 - DEMOLITION HVAC PLAN

SHEET INDEX

MHD190 PENTHOUSE - DEMOLITION HVAC PLAN

MPD170 LEVEL 7 - DEMOLITION HYDRONIC PIPING PLAN

MH160 LEVEL 6 - HVAC PLAN

MH170 LEVEL 7 - HVAC PLAN - OVERALL

MH171 LEVEL 7 - HVAC PLAN - AREA A

MH172 LEVEL 7 - HVAC PLAN - AREA B

MH180 8TH LEVEL - HVAC PLAN

MH190 PENTHOUSE - HVAC PLAN

MP170 LEVEL 7 - HYDRONIC PIPING PLAN

MP190.A PENTHOUSE - HYDRONIC PIPING PLAN - BASE BID

MP190.B PENTHOUSE - HYDRONIC PIPING PLAN - BID DEDUCT #3

M191 PENTHOUSE UNDERFLOOR - MECHANICAL PLAN

M192 ROOF - MECHANICAL PLAN

M200 MECHANICAL ELEVATIONS

M300 MECHANICAL DETAILS

M301 AIR HANDLER SCHEMATIC

M302 ENERGY RECOVERY UNIT AND AIR FILTER SCHEMATICS

M303.A PIPING FLOW DIAGRAM - BASE BID

M303.B PIPING FLOW DIAGRAM - BID DEDUCT #3

M401 MECHANICAL SCHEDULES

ME402 MECHANICAL AND ELECTRICAL SCHEDULES

M500.A SEQUENCES OF OPERATIONS - BASE BID

M500.B SEQUENCES OF OPERATIONS - BID DEDUCT #3

M501 SEQUENCES OF OPERATIONS

09 - ELECTRICAL

E000 ELECTRICAL TITLE SHEET

ED171 7TH LEVEL - DEMOLITION ELECTRICAL LIGHTING PLAN

ED172 7TH LEVEL - DEMOLITION ELECTRICAL POWER PLAN

ED173 7TH LEVEL - DEMOLITION ELECTRICAL SYSTEMS PLAN

ED181 8TH LEVEL - DEMOLITION ELECTRICAL DEMOLITION PLAN

ED191 PENTHOUSE/ROOF - DEMOLITION ELECTRICAL PLAN

EL171 7TH LEVEL - LIGHTING PLAN AREA A

EL172 7TH LEVEL - LIGHTING PLAN AREA B

EL191 PENTHOUSE/ROOF - ELECTRICAL LIGHTING PLAN

EP171 7TH LEVEL - POWER PLAN AREA A

EP172 7TH LEVEL - POWER PLAN AREA B

EP181 LEVEL 8 - ELECTRICAL POWER PLAN

EP191 PENTHOUSE/ROOF - ELECTRICAL POWER PLAN

EY171 7TH LEVEL - SYSTEMS PLAN AREA A

EY172 7TH LEVEL - SYSTEMS PLAN AREA B

EE300 ELECTRICAL RISER

EE301 ELECTRICAL RISER

EE500 ELECTRICAL DETAILS

EE600 ELECTRICAL SCHEDULES

EE601 ELECTRICAL SCHEDULES

TOTAL SHEET COUNT: 127

Revision# Description Date:

Figure 302.2 Carpet Pile Height

Figure 303.2 Vertical Change in Level

1/ 2" m ax

1/ 4" m ax

Figure 302.3 Elongated Openings in Floor or

Ground Surfaces d ir ec ti o n o f tr av el lo n g d im d o m in an t p er p in d ic u la r to

1/2" max dominant direction of travel

Figure 303.3 Beveled Change in Level

1/

1/

1/

1/

Figure 304.3.1.2 Circular Turning Space - Existing

Buildings Size and Overlap

Figure 304.3.1.1 Circular Turning Space - New Buildings Size and Overlap m ax

Overlap of knee and toe clearnce Overlap of knee and toe clearnce

6.

2.

m ax

P er ø 5'-7" min ø 5'-0" min

Figure 304.3.2.2 T-Shaped Turning Space New Buildings - Size and Overlap ar m ar m base

Figure 304.3.2.1(A) T-Shaped Turning Space New Buildings - Option 1 ar m ar m base

68" min min

16" min

36" min

16" m in m in36 m in

Figure 304.3.2.1(B) T-Shaped Turning Space New Buildings - Option 2 ar m ar m base

64" min min

11" min

42" min

11" m in m in m in

Figure 304.3.2.1(C) T-Shaped Turning Space New Buildings - Option 3 ar m ar m base

64" min min

12" min

40" min

12" m in m in m in

60" min min

12" min

36" min

12" m in36 m in m in

Figure 305.3.2 Clear Floor or Ground

Space- Existing Buildings

Figure 305.5 Position of Clear Floor or Ground Space

Figure 305.7.1 Maneuvering Clearance in an

Alcove, Forward Approach

Figure 305.7.2 Maneuvering Clearance in an

Alcove, Parallel Approach

(a) forward

(b) parallel

Figure 305.3.1 Clear Floor or Ground Space- New Buildings

52" min m in

48" min m in

30" min m in

48" min m in

36" min

X

4"

60" min

X

5"

Figure 306.2 Toe Clearance

Figure 306.3 Knee Clearance

(b) plan

(a) elevation

9"

6" max m in

17"- 25"

(b) plan

(a) elevation m in

25" max

11" min

8" min m in

Figure 307.2 Limits of Protruding Objects

4" max

X

7"

X

0"

Figure 307.3 Post-Mounted Protruding Objects

(b)(a)

0"

12" max 12" max m ax X > 12"

X > 12" m in

Figure 307.4 Vertical Clearance

M ax

X

Figure 308.3.1 Unobstructed Side Reach

Figure 308.3.2 Unobstructed High Side Reach

Figure 308.2.2 Obstructed High Forward Reach

Figure 308.2.1 Unobstructed

Forward Reach

(a) (b)

(b)(a) m in m ax m ax

20" max m ax

20"- 25" max

10" max m in m ax

10" max 10" - 24" max m ax m ax m ax m ax

B U

IL

D

IN

G

B L

O C

K S m in

48" min

Figure 1104.1.1 Clear Floor Space

For type B Unit

(a) front or rear entry

(b) side entry

Figure 802.1.3 Depth of Wheelchair Spaces in

Assembly Area

(a) single space

(b) two spaces

Figure 802.1.2 Width of Wheelchair Spaces in

Assembly Area

36" min 33" min 33" min m in m in

Figure 802.4(a) Depth of Wheelchair Spaces in Assembly Area - New Building m in

W H

E E

L C

H A

IR

S

P A

C E

S

Figure 403.5.2 Clear Width at Turn Existing Buildings

Figure 403.5.1 Clear Width of an Accessible Route

(a) 180 degree turn

(b) 180 degree turn

(Exception)

Figure 403.5.2.1 Clear Width at Turn

(A) 180 degree turn

New Buildings - Option 1 m in

(B) 180 degree turn

New Buildings - Option 2 m in

(C) 180 degree turn

New Building - Option 3 m in

38" min m in

36" min m in

Figure 403.5.3.1 Clear Width At 90-Degree Turn

36" min m in

4" min 28" min

4" m in m in

Figure 403.5.3.2 Clear Width At 90-Degree Turn

Existing Buildings

36" min m in

Figure 403.5.3.1 Clear Width At 90-Degree Turn

Existing Buildings

36" min m in

36" min

X<52"

36" min 42" min

X<52"

42" min 43" min

X<52"

43" min m in m in

42" min

X<48"

42" min 36" min

X<48"

36" min

32" min

36" min

32" min

36" min m ax m in m ax

(a) 90 degree trun

New Building - Option 1

(b) 90 degree trun

New Building - Option 2

(c) 90 degree trun

New Building - Option 3

A C

C E

S S

IB

L

E R

O U

T E

S

1. ALL CONSTRUCTION & RENOVATION SHALL MEET THE ARCHITECTURAL BARRIERS ACT

ACCESSIBILITY STANDARD (ABAAS).

2. SUPPLEMENTAL TO THE (ABAAS), CONSTRUCTION & RENOVATION IN HEALTH FACILITIES OF

THE DEPARTMENT OF VETERAN AFFAIRS (VA) SHALL COMPLY WITH THE VA BARRIER FREE

DESIGN STANDARD: A SUPPLEMENT TO THE ARCHITECTURAL BARRIERS ACT

ACCESSIBILITY STANDARDS (PG-18-13).

GENERAL NOTES

OVERRIDE BY VA BARRIER FREE

DESIGN STANDARD

MINIMUM REQUIREMENTS

• SITES - PARKING SPACES ACCESSIBLE 1% GREATER THAN ABAAS

• SPINAL CORD INJURY/DISORDER (SCI/D) FACILITIES: 0.2 ACCESSIBLE SPACES PER

INPATIENT BED; 0.5 PER LONG-TERM CARE BED; 5.6 PER OUTPATIENT EXAM ROOM.

DEDICATED FOR SCI/D PATIENTS

• HOSPITAL OUTPATIENT FACILITIES 10% OF TOTAL SPACES

• REHABILITATION AND OUTPATIENT

PHYSICAL THERAPY FACILITIES 20% OF TOTAL SPACES

• BUILDING-ACCESSIBLE SEATING, ASSEMBLY AREAS 1% GREATER THAN ABAAS

ACCESSIBLE ROUTE

• WIDTH, MIN. PATIENT CARE AREAS 6'-0"

• WIDTH, MIN. ADMINISTRATIVE AREA 5'-0"

• SLOPE, MAXIMUM (INCLUDING PARKING SPACES) 1:50 (2%)

• MINIMUM GRADIENT OF WALK REQUIRING REST

AREAS EVERY 200' 1:50 (2%)

• TURNING RADIUS 5'-6"

• TURNING RADIUS, BARIATRIC 6'-0"

• T-SHAPED TURNING SPACE 5'-6" x 5'-6"

• T-SHAPED TURNING SPACE, BARIATRIC 6'-0" x 6'-0"

FLOOR SURFACES

• CHANGES IN LEVEL NOT PERMITTED ON SCI FLOORS

• CARPET CUSHION OR PADDING NOT PERMITTED

PARKING & PASSENGER LOADING ZONES

• ACCESS AISLE REQUIREMENT FOR ACCESSIBLE

PARKING SPACES 5'-0" EACH SIDE

• PASSENGER LOADING AREA

"COMMUNICATION SYSTEM" FOR ASSISTANCE AT SCI UNITS YES

CURB RAMPS

• WIDTH, MINIMUM 4'-0"

RAMPS

• MAXIMUM SLOPE 1:20

• MAXIMUM LENGTH, WITHIN RANGE OF 1:33 - 1:26 40'

• MAXIMUM LENGTH, WITHIN RANGE OF 1:25 - 1:20 35'

• MINIMUM CLEAR WIDTH 4'-0"

• MINIMUM SIZE LEVEL LANDING,

WHERE DOORS SWING INTO LANDING 6'-0" X 6'-0"

STAIRS

• HANDRAIL HEIGHT 34"

ELEVATOR (PASSENGER)

• MINIMUM WIDTH OF ELEVATOR DOORS 4'-0"

• MINIMUM CAR SIZE 8'-0" X 6'-2" PLATFORM SIZE

• DOUBLE SET OF HANDRAILS YES

WINDOWS

• SILL HEIGHT IN PATIENT BEDROOMS 24" MAXIMUM

DOORS & DOORWAYS

• PATIENT CARE DELIVERY AREAS WITH PATIENT BED,

STRETCHER OR GURNEY ACCESS, MINIMUM WIDTH 4'-0"

WATER CLOSETS - INPATIENT NURSING UNITS

• GRAB BAR CONFIGURATION: DOUBLE SWING-UP BARS FOR ALL PATIENT TOILETS/SHOWER

ROOMS ON NURSING UNITS.

TOILET STALLS

• MINIMUM ACCESSIBLE STALL SIZE 5'-6" X 6'-0"

• MINIMUM SIZE WHEELCHAIR "FRONT-TRANSFER" STALL 3'-6" X 6'-0"

• GRAB BARS REQUIRED IN ALL STALLS

SHOWER STALLS (PATIENT)

• MINIMUM STALL DIMENSIONS 4'-0" X 4'-0"

• GRAB BARS HORIZONTAL PLUS VERTICAL BARS

TOILET ROOMS

• INPATIENT BEDROOM TOILET ROOMS,

MINIMUM WIDTH OF TOILET ROOM ENTRANCE DOORS 48"

CAFETERIAS

• KNEE CLEARANCE, FOR MINIMUM 5% TABLES 2'-3" & 2'-5" FOR AT LEAST 5%

• CUTLERY AND SUPPLY HEIGHT 40" - 48"

HEALTH CARE FACILITIES

• MEDICAL/SURGICAL NURSING UNITS,

PERCENT OF PATIENT BEDROOMS ACCESSIBLE 100%

• MEDICAL/SURGICAL NURSING UNITS,

PERCENT OF TOILET ROOMS ACCESSIBLE 100%

Sanitary Napkin Disposal

Sanitary Napkin Dispenser m ax

Soap Dispenser

Paper Towel Dispenser

T .O

. d is p en se r

O P

G m ax

Baby Changing Station to B

.O m in to h ig h es t p ar t m ax

LINE OF WALL

Coat/Robe Hook

4' -0

A

C C

5' -4

T

Y P

Door Viewer

3' -7

A

C C

5' -0

T

Y P

Mirror Height to g la ss

Fire Extinguisher Cabinet m ax t o t h e h an d le m ax

Fire Extinguisher m ax t o t h e h an d le m ax

Hand Dryer

Trash Receptical m ax w o rk s u rf ac e o f w o rk s u rf ac e

T .O

. o p er ab le p o rt io n m ax

Toilet Seat Cover Dispenser

M O

U N

T

IN

G H

E

IG

H T

S

Figure 602.2.1 (A) Clear Floor Space at Wheelchair Drinking

Fountains

Figure 602.2.1 (B) Clear Floor Space at Wheelchair Drinking Fountains Primarly for

Children's use Exception

Children Adults

Figure 602.2.3 Wheelchair Drinking

Fountain Spout Height and Location

-4 m ax

-4 m ax

Figure 602.3.2 Standing use Drinking Fountain Spout Height and Location

Figure 602.3.3 Drinking Fountain

Spout Location m ax m ax

Children Adults

5" max (602.2.4)

15" min for Adults

D R

IN

K

IN

G

F O

U N

T A

IN

S

Figure 504.2 Treads and Risers

Figure 504.5 Stair Nosings

Figure 505.4 Handrail Height

Figure 505.5 Handrail

Clearance

Figure 505.6 Horizontal

Projections Below Gripping Surface

Figure 505.7.2 Handrail Non-Circular Cross Section

Figure 505.10.1 Top and Bottom Handrail

Extensions at Ramps

Figure 505.10.2 Top Handrail

Extension at Stairs

Figure 505.10.3 Bottom Handrail

Extension at Stairs

(a) radius of tread edge

(typical for all profiles)

(b) angled riser

(c) curved nosing

(d) beveled nosing

(a) stairs

(b) ramps

(c) walking surfaces Note: X = tread depth

7" m ax 4" m in

11" min

1 1/2" max 1 1/2" max radius 1/2" max 30° max

"34

1 1/2" min

1/

2" m in

4" - 6 1/4" perimeter

2 1 /4" m ax 2 1/4" max

12" min 12" min

12" min

XX

G E

N E

R A

L S

IT

E

A N

D B

U

IL

D

IN

G E

L E

M E

N T

S

Figure 404.2.4.3 Maneuvering Clearance at Recessed Doors and Gates

Figure 404.2.4.2 Maneuvering Clearance at Sliding and Folding Doors

Figure 404.2.4.1 Maneuvering Clearance at Manual Swinging Doors and Gates

Figure 404.2.3 Clear Width of Doorways

Figure 404.2.6 Doors in Series and Gates in Series

(e) hinge approach, pull side

(j) latch approach, push side

(k) latch approach, push side

*48 min if door provided with closer

(i) latch approach, pull side

*54 min if door provided with closer

(h) latch approach, pull side

(f) hinge approach, push side

(g) hinge approach, push side

*if door provided with both closer and latch ** 48 min if both closer and latch provided

(b) front approach, push side

(c) front approach, push side

*if door provided with both closer and latch

(a) front approach, pull side

(a) hinged door

(b) sliding door

(c) folding door

(d) doorways without doors

(a) pull side

(b) push side

(c) push side, door provided with both closer and latch

(a) front approach

(b) side approach

*48 min at front approach

(c) pocket or hinge approach

(d) stop or latch approach

(d) hinge approach, pull side

(a)

(c)

(b)

(d) front approach symbol

32" min

32" min

32" min

36" min

18" min m in m in

*12" min

36" min 60 m in

42" min m in

2" m in

22" min* 12" min m in

24" min

24" min m in m in m in

22" min m in m in

24" min m in

18" min

X >8

X >8 m in m in

12" min

X >8

48" min

48" min

48" min m in

66" min D O

O R

S A

N D

G A

T E

S

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ARCHITECT OF RECORD

A/E:

STAMPCONSULTANTS

o n e e ig h th in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s in c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h e s o n e f o o t th re e in c h e s o n e f o o t

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

MECHANICAL / ELECTRICAL / PLUMBING: STRUCTURAL:HEALTHCARE ARCHITECT:

2550 UNIVERSITY AVE. W. SUITE 423-S

ST. PAUL, MN 55114

651.251.7570

50 SOUTH 6TH ST UNIT 1100

MINNEAPOLIS, MN 55402

612.465.7550

380 ST. PETER ST. UNIT 600

ST. PAUL, MN 55102

651.222.3701

C U s e rs

\T .L a rs o n \D o c u m e n ts

\2

M D

I n

P a t

B T a n n e rL

N

S

C .r v t

/1

/2

:5

:4

A

M

GI101

ACCESSIBILITY DETAILS

Stone Group Architects

600 E 7th Street

Sioux Falls, SD 57103

605-271-1144

RENOVATE INPATIENT WARD - 7B

2500 OVERLOOK TERRACE, MADISON, WI 53705

05/17/2024 JHK / IEP TDL

100% CONSTRUCTION

DOCUMENTS

SGA #231919

VA #607-22-101

Figure 604.2 Water Closet

Location

(a) wheelchair accessible water closets

(b) ambulatory accessible

Water closets

Figure 604.3.1 Size of Clearance at

Water Closets

Figure 604.3.2 (exception) Overlap of Water Closet Clearance in Residential

Dwelling Units

Figure 604.5.1 Side Wall Grab Bar at

Water Closets

Figure 604.5.2 Rear Wall Grab Bar at Water Closets

Figure 1104.11.1.1 Swing-up Grab Bar for Water Closet

Figure 604.7 Dispenser Outlet Location

Transfer Side comply with section 609.3 m in m ax7" - 9"

18" min 18" min

15 3/4" 15 3/4"36" min

24" min min

12" 12" max 42" min

54" min

42" m in

39" - 41" m in m in

60" min

18" min m in

60" min

16" - 18"

17" - 19"

P L

U M

B

IN

G E

L E

M E

N T

S A

N D

F A

C

IL

IT

IE

S

Figure 609.2.2 Grab Bar Non-Circular Cross Section

4" - 4.8" perimeter

2" m ax 2" max

(a) (b)

Figure 608.3.1 Grab Bars for Transfer-

Type Showers

Figure 608.3.2 Grab Bars for Standard Roll-In Type Showers

Figure 608.3.3 Grab Bars for Alternate Roll-In Type Showers seat wall control wall back wall back wall side wall side wall back wall back wall front wall side wall side wall side wall side wall

(b) with seat

Figure 608.2.1.2(B) Transfer-Type Shower Compartment Clearances

New Buildings- Option 2 seat wall control wall back wall

52" max m ax

4" max

Figure 608.2.1.2(C) Transfer-Type Shower Compartment Clearances

Existing Buildings- Option 2 seat wall control wall back wall m ax

48" max

18"

4" M ax

6" m ax

6" m ax

6" max 6" max

6" max6" max

6" m ax

Figure 608.5.1 Transfer-Type Shower Compartment Control

Location

Figure 608.5.2 Standard Roll-In Type Shower Compartment

Control Location

Figure 608.5.3 Alternate Roll-In Type Shower Compartment Control Location

Figure 609.3 Spacing of Grab Bars side wall back wall can be located on any wall of shower

(a) without seat

(b) with seat

(a) projecting objects

(b) recessed objects side wall back wall

(a) with seat

(elevation)

(b) with seat

(elevation)

(d) with seat

(plan)

(c) without seat

(plan) side wall side wall side wall side wall back wallback wall front wall front wall

15" max m in m ax m in m ax m ax

Figure 610.3 Extent of Seat

Figure 610.3.1 Rectangular Shower Seat

Figure 610.3.2 L-Shaped Shower Seat seat wall seat wall

(a) size

(b) distance from wall seat wall

(a) rectangular

(b) L-shaped compartment entry compartment entry

15" max m in

1/

2" m ax

3" m ax

3" m ax

(a) without seat

2 1/2" max

15" - 16"

1/

2" m ax

2 1/2" max15" - 16"

22" - 23"

1/

2" m ax m in m ax

27" max m in m ax m in

6" m ax

6" max

T U

B S

A N

D S

H O

W E

R S

Figure 703.6.1 Pictogram Field

MEN not in pictogram field

6" M in

Figure 705.1 Size and Spacing of Truncated Domes base diameter of 0.9"-1.4" top diameter of 50%-65% of the base diameter

(a) elevation (enlarged)

(b) plan

.6 5"

M in

1.6" - 2.4"

1.

6"

.4

Figure 707.6.2 Numeric Key Layout

(a) 12-key ascending

(b) 12-key descending

1 2 3

4 5 6

7 8 9

* 0 #

7 8 9

4 5 6

1 2 3

* 0 #

Figure 703.2.5 Height of Raised

Characters

LIBRARY

5/ 8"

"0.

2"

Figure 703.3.1 Braille Measurement single braille cell blank cell space between words raised dot no raised dot

Figure 703.3.2 Position of Braille

AREA OF

REFUGE

3/ 8" m in

3/ 8" m in

Figure 703.7.2.1 International Symbol of Accessibility

Figure 703.7.2.2 International TTY Symbol

Figure 703.7.2.3 Volume-Controlled Telephone

Figure 703.7.2.4 International Symbol of Access for

Hearing Loss

Figure 704.2.1.1 Parallel Approach to

Telephone

Figure 704.2.1.2 Forward Approach to

Telephone

Figure 703.4.1 Height of Tactile Characters

Above Floor or Ground

Figure 703.4.2 Location of Tactile Signs at Doors

AREA OF

REFUGE

centered on tactile characters

AREA OF

REFUGE

M ax

M ax

M in

M ax

18" Min

M in distance between corresponding dots from one cell directly below distance between dots in the same cell distance between corresponding dots in adjacent cells distance between dots in the same cell base diameter

C O

M M

U N

IC

A

T

IO

N E

L E

M E

N T

S A

N D

F E

A T

U R

E S

1. ALL CONSTRUCTION & RENOVATION SHALL MEET THE ARCHITECTURAL BARRIERS ACT

ACCESSIBILITY STANDARD (ABAAS).

2. SUPPLEMENTAL TO THE (ABAAS), CONSTRUCTION & RENOVATION IN HEALTH FACILITIES OF

THE DEPARTMENT OF VETERAN AFFAIRS (VA) SHALL COMPLY WITH THE VA BARRIER FREE

DESIGN STANDARD: A SUPPLEMENT TO THE ARCHITECTURAL BARRIERS ACT

ACCESSIBILITY STANDARDS (PG-18-13).

GENERAL NOTES

OVERRIDE BY VA BARRIER FREE

DESIGN STANDARD

MINIMUM REQUIREMENTS

• SITES - PARKING SPACES ACCESSIBLE 1% GREATER THAN ABAAS

• SPINAL CORD INJURY/DISORDER (SCI/D) FACILITIES: 0.2 ACCESSIBLE SPACES PER

INPATIENT BED; 0.5 PER LONG-TERM CARE BED; 5.6 PER OUTPATIENT EXAM ROOM.

DEDICATED FOR SCI/D PATIENTS

• HOSPITAL OUTPATIENT FACILITIES 10% OF TOTAL SPACES

• REHABILITATION AND OUTPATIENT

PHYSICAL THERAPY FACILITIES 20% OF TOTAL SPACES

• BUILDING-ACCESSIBLE SEATING, ASSEMBLY AREAS 1% GREATER THAN ABAAS

ACCESSIBLE ROUTE

• WIDTH, MIN. PATIENT CARE AREAS 6'-0"

• WIDTH, MIN. ADMINISTRATIVE AREA 5'-0"

• SLOPE, MAXIMUM (INCLUDING PARKING SPACES) 1:50 (2%)

• MINIMUM GRADIENT OF WALK REQUIRING REST

AREAS EVERY 200' 1:50 (2%)

• TURNING RADIUS 5'-6"

• TURNING RADIUS, BARIATRIC 6'-0"

• T-SHAPED TURNING SPACE 5'-6" x 5'-6"

• T-SHAPED TURNING SPACE, BARIATRIC 6'-0" x 6'-0"

FLOOR SURFACES

• CHANGES IN LEVEL NOT PERMITTED ON SCI FLOORS

• CARPET CUSHION OR PADDING NOT PERMITTED

PARKING & PASSENGER LOADING ZONES

• ACCESS AISLE REQUIREMENT FOR ACCESSIBLE

PARKING SPACES 5'-0" EACH SIDE

• PASSENGER LOADING AREA

"COMMUNICATION SYSTEM" FOR ASSISTANCE AT SCI UNITS YES

CURB RAMPS

• WIDTH, MINIMUM 4'-0"

RAMPS

• MAXIMUM SLOPE 1:20

• MAXIMUM LENGTH, WITHIN RANGE OF 1:33 - 1:26 40'

• MAXIMUM LENGTH, WITHIN RANGE OF 1:25 - 1:20 35'

• MINIMUM CLEAR WIDTH 4'-0"

• MINIMUM SIZE LEVEL LANDING,

WHERE DOORS SWING INTO LANDING 6'-0" X 6'-0"

STAIRS

• HANDRAIL HEIGHT 34"

ELEVATOR (PASSENGER)

• MINIMUM WIDTH OF ELEVATOR DOORS 4'-0"

• MINIMUM CAR SIZE 8'-0" X 6'-2" PLATFORM SIZE

• DOUBLE SET OF HANDRAILS YES

WINDOWS

• SILL HEIGHT IN PATIENT BEDROOMS 24" MAXIMUM

DOORS & DOORWAYS

• PATIENT CARE DELIVERY AREAS WITH PATIENT BED,

STRETCHER OR GURNEY ACCESS, MINIMUM WIDTH 4'-0"

WATER CLOSETS - INPATIENT NURSING UNITS

• GRAB BAR CONFIGURATION: DOUBLE SWING-UP BARS FOR ALL PATIENT TOILETS/SHOWER

ROOMS ON NURSING UNITS.

TOILET STALLS

• MINIMUM ACCESSIBLE STALL SIZE 5'-6" X 6'-0"

• MINIMUM SIZE WHEELCHAIR "FRONT-TRANSFER" STALL 3'-6" X 6'-0"

• GRAB BARS REQUIRED IN ALL STALLS

SHOWER STALLS (PATIENT)

• MINIMUM STALL DIMENSIONS 4'-0" X 4'-0"

• GRAB BARS HORIZONTAL PLUS VERTICAL BARS

TOILET ROOMS

• INPATIENT BEDROOM TOILET ROOMS,

MINIMUM WIDTH OF TOILET ROOM ENTRANCE DOORS 48"

CAFETERIAS

• KNEE CLEARANCE, FOR MINIMUM 5% TABLES 2'-3" & 2'-5" FOR AT LEAST 5%

• CUTLERY AND SUPPLY HEIGHT 40" - 48"

HEALTH CARE FACILITIES

• MEDICAL/SURGICAL NURSING UNITS,

PERCENT OF PATIENT BEDROOMS ACCESSIBLE 100%

• MEDICAL/SURGICAL NURSING UNITS,

PERCENT OF TOILET ROOMS ACCESSIBLE 100%

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ARCHITECT OF RECORD

A/E:

STAMPCONSULTANTS

o n e e ig h th in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s in c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h e s o n e f o o t th re e in c h e s o n e f o o t

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

MECHANICAL / ELECTRICAL / PLUMBING: STRUCTURAL:HEALTHCARE ARCHITECT:

2550 UNIVERSITY AVE. W. SUITE 423-S

ST. PAUL, MN 55114

651.251.7570

50 SOUTH 6TH ST UNIT 1100

MINNEAPOLIS, MN 55402

612.465.7550

380 ST. PETER ST. UNIT 600

ST. PAUL, MN 55102

651.222.3701

C U s e rs

\T .L a rs o n \D o c u m e n ts

\2

M D

I n

P a t

B T a n n e rL

N

S

C .r v t

/1

/2

:5

:4

A

M

GI102

ACCESSIBILITY DETAILS

Stone Group Architects

600 E 7th Street

Sioux Falls, SD 57103

605-271-1144

RENOVATE INPATIENT WARD - 7B

2500 OVERLOOK TERRACE, MADISON, WI 53705

05/17/2024 JHK / IEP TDL

100% CONSTRUCTION

DOCUMENTS

SGA #231919

HORIZONTAL BUILDING SEPARATION

ALLOWANCE

NONE NONE 510.2 FOR

REQUIREMENTS

INCIDENTAL USES SEPARATION IF REQUIRED SOILED, LINEN, CLEAN, STORAGE > 100 SF 1 HOUR SEPARATION TABLE 509

SEPARATION OF OCCUPANCIES IF REQUIRED N/A TABLE 508.4

ALLOWABLE AREA UNLIMITED 640,987 SF (7TH FLOOR = 38,197 SF) TABLE 506.2

SPRINKLER SYSTEM FULL SPRINKLER SYSTEM NFPA 13

ALLOWABLE NUMBER OF STORIES ABOVE

GRADE PLANE

UNLIMITED 8-STORIES ABOVE STREET LEVEL TABLE 504.4

ALLOWABLE BUILDING HEIGHT IN FEET

ABOVE GRADE

UNLIMITED 119' TABLE 504.3

BUILDING CONSTRUCTION TYPE TYPE I (332) (NFPA), TYPE I-A (IBC) TABLE 503

ADDRESS IDENTIFICATION 501.2

BUILDING HEIGHTS & AREAS SPRINKLER SYSTEM INSTALLED IBC CHAPTER 5

SPECIALTY OCCUPANCY REQUIREMENTS N/A IBC CHAPTER 4

HEALTH CARE (NFPA), I-2 (IBC)

OCCUPANCY GROUP

NFPA CHAPTER 6

IBC CHAPTER 3

BUILDING CLASSIFICATION

HEIGHT

LOT FRONTAGE

STREET SIDE YARD

SIDE

REAR

FRONT

SETBACKS REQ N/A

NUMBER OF VAN ACCESSIBLE STALLS

REQUIRED

NUMBER OF ACCESSIBLE STALLS REQUIRED

NUMBER OF STALLS REQUIRED

PARKING REQ: N/A

NFPA/IBC REQUIRED ACTUAL PROVIDED 1/3

PERMIT REQ'D Y/N: NO

SEWAGE TREATMENT: CITY OF MADISON

WATER SUPPLY: CITY OF MADISON

FIRE SERVICE: CITY OF MADISON FIRE DEPARTMENT

INSPECTION: VISN 12 SAFETY OFFICER

* 2015 ARCHITECTURAL BARRIERS ACT (ABA) STANDARDS

* 2021 INTERNATIONAL FIRE CODE

* 2021 INTERNATIONAL PLUMBING CODE

* 2021 INTERNATIONAL MECHANICAL CODE

* 2021 NATIONAL ELECTRICAL CODE

* 2021 INTERNATIONAL BUILDING CODE

APPLICABLE CODES: * 2021 NFPA 101 LIFE SAFETY CODE

SITE AREA: MULTI BUILDING SITE

SITE ADDRESS: 2500 OVERLOOK TERRACE, MADISON, WI 53705

PARCEL NO: N/A

RENOVATE INPATIENT WARD - 7B

PROJECT NO: 231919

CODE REVIEW

7TH FLR - B WING 3 FEC 3 FEC

NUMBER OF FEC REQUIRED PER FLR

MAX TRAVEL DISTANCE TO FEC 75 FEET < 75 FEET TABLE 906.3(1)

MAXIMUM FLOOR AREA FOR

EXTINGUISHER

11,250 SQ FT < 11,250 SQ FT

MAXIMUM FLOOR AREA PER UNIT OF

CLASS A

3,000 SQ FT < 3,000 SQ FT

MINIMUM RATED SINGLE EXITNGUISHER EXT TYPE = 2-A 2-A NFPA 10 - CH. 6

FIRE EXTINGUISHER REQUIREMENTS

FIRE DEPARTMENT ACCESS WITHIN 300 FT OF ALL PORTIONS OF THE FIRST

FLOOR OF THE BUILDING

AUTOMATIC SPRINKLER SYSTEM NFPA 13 NFPA 13 - FULLY AUTOMATIC, SUPERVISED

SYSTEM

TABLE 903.2

FIRE PROTECTION SYSTEMS REVIEW INTERNATIONAL FIRE CODE (IFC) IBC CHAPTER 9

INTERIOR FINISHES IBC CHAPTER 8

DRAFT STOPS IN ATTIC N/A 717.4.3

DRAFT STOPS IN FLOORS N/A 717.3.3

FIRE WALL 706.1 MOST RESTRICTIVE OCCUPANCY SHALL

GOVERN IF FIRE WALLS ARE REQUIRED

706.1

MAXIMUM AREA OF EXTERIOR WALL

OPENINGS

UNLIMITED (EXCEEDS 30'-0" AND IS FULLY

SPRINKLED BUILDING)

TABLE 705.8

FIRE WALLS REQUIRED (Y/N) NO SECTION 706

TABLE 705.8

BUILDINGS ON THE SAME LOT (Y/N) YES SECTION 705.3

30 FEET OR GREATER 20 FEET TABLE 705.2

GREATER THAN 3 FEET TO LESS THAN

30 FEET

24 INCHES PLUS 8 INCHES FOR EVERY FOOT OF

FSD BEYOND 3 FEET OR FRACTION THEREOF

TABLE 705.2

GREATER THAN 2 FEET TO 3 FEET 24 INCHES TABLE 705.2

O FEET TO 2 FEET PROJECTIONS NOT PERMITTED TABLE 705.2

EXTERIOR PROJECTIONS N/A TABLE 705.2

SYSTEM IN PLACE FULLY AUTOMATIC SPRINKLER SYSTEM INSTALLED

FIRE & SMOKE PROTECTION IBC CHAPTER 7

SHAFT WALL 2 EXISTING

ELEVATOR 2 EXISTING

STAIRS 2 EXISTING

ROOF CONSTRUCTION

EXCEPTION

1 1/2

EXISTING

0 (NEW PENTHOUSE)

1511.2.4 - EXCEPT. 1

FLOOR CONSTRUCTION 2 EXISTING

1 1/2 (NEW PENTHOUSE)

BEAMS, GIRDERS, TRUSSES, & ARCHES

(SUPPORTING ONE FLOOR ONLY)

EXISTING

2 (NEW PENTHOUSE)

COLUMNS

(SUPPORTING ONE FLOOR ONLY)

EXISTING

2 (NEW PENTHOUSE)

NON BEARING WALLS AND PARTITIONS -

INTERIOR

0 SEE LIFE SAFETY PLANS

TABLE 601

NONBEARING WALLS AND PARTITIONS -

EXTERIOR

0 0 (NEW PENTHOUSE)

TABLE 602

INTERIOR 3 EXISTING TABLE 601

EXTERIOR 3 EXISTING TABLE 601

BEARING WALLS

PRIMARY STRUCTURE 3 EXISTING TABLE 601

CONSTRUCTION TYPE: TYPE I (332) (NFPA), TYPE I-A (IBC)

NFPA 220 CHAPTER 4

IBC CHAPTER 6

NFPA/IBC REQUIRED ACTUAL PROVIDED 2/3

See Chapter 6 for Rated assemblies

UL-RATED SYSTEMS AND DESIGN

NUMBER SEE WALL TYPE LEGEND / BUILDING SECTIONS

SOUND TRANSMISSION STC RATING OF AT LEAST 50 BETWEEN ADJACENT

PATIENT ROOMS AND AT LEAST 35 BETWEEN

PATIENT ROOMS AND ADJACENT PUBLIC SPACES.

SECTION 1206

LABELING FIRE WALLS LABEL ALL FIRE WALLS ABOVE ALL ACT CEILINGS. SECTION 703.7

MISCELLANEOUS INFORMATION

SPECIALTY REQUIREMENTS NONE

REQUIRED? YES EXISTING

ELEVATORS & CONVEYING SYSTEMS CHAPTER 30

SERVICE SINK 1 1 TABLE 2902.1

DRINKING FOUNTAINS 1 PER 100 1 (BOTTLE FILLING STATION) TABLE 2902.1

LAVATORIES - EMPLOYEES 1 PER 35 1

LAVATORIES - CARE RECIPIENTS 1 PER ROOM 1 PER ROOM TABLE 2902.1

WATER CLOSETS - EMPLOYEES 1 PER 25 1

WATER CLOSETS - CARE RECIPIENTS 1 PER ROOM 1 PER ROOM TABLE 2902.1

OCCUPANCY #

MINIMUM NUMBER OF REQUIRED

PLUMBING FIXTURES

REQUIRED TYPE OF FIXTURES PROVIDED TYPE OF FIXTURE TABLE 2902.1

PLUMBING SYSTEMS CHAPTER 29

SPECIAL OCCUPANCIES I-2 HOSPITALS: 10% MINIMUM (VA: 100%) 100% SECTION 1108

ACCESSIBLE DWELLING UNITS & SLEEPING

UNITS

N/A TABLE 1107.6.1.1

ACCESSIBLE ROUTES FOR DWELLINGS N/A SECTION 1107.4

ACCESSIBLE PARKING SPACES N/A TABLE 1106.1

ACCESSIBLE ENTRANCES MINIMUM 60% EXISTING BUILDING SECTION 1105

ACCESSIBLE ROUTE AT LEAST ONE ACCESSIBLE ROUTE. EXISTING BUILDING SECTION 1104

REQUIREMENTS APPLICABLE EXCEPTIONS? NONE SECTION 1103

ACCESSIBILITY CHAPTER 11

DEAD END CORRIDOR LENGTH 30' N/A NFPA 101-18.2.5.3

EXCEPTION 3: UNOCCUPIED MECHANICAL ROOMS

AND PENTHOUSES ARE NOTE REQUIRED TO

COMPLY WITH THE COMMON PATH OF EGRESS

TRAVEL DISTANCE MEASUREMENT.

1006.2.1

MAX COMMON PATH OF TRAVEL 100' 28' NFPA 101-18.2.5.2

ALLOWABLE EXIT ACCESS TRAVEL

DISTANCE

200' (PATIENT ROOM TO EXIT DOOR = 50') 93'-1" ( PATIENT ROOM TO EXIST DOOR = 28') NFPA 101-18.2.6

AREA OF REFUGE REQUIRED NO FULLY SPRINKLED BUILDING SECTION 1009

SMOKE BARRIERS REQUIRED IN HOSPITAL FLOORS OVER 22,500 SF GROSS 7B = 11,400 SF NFPA 101-18.3.7

MEANS OF EGRESS ILLUMINATION

REQUIRED?

YES SEE SECTION 1008

MINIMUM NUMBER OF EXITS OR ACCESS

TO EXITS PER STORY

2 5 TABLE 1006.3.1

SPECIAL EXCEPTIONS NONE 1006.2

MINIMUM DOOR WIDTH, PATIENT ROOM 41 1/2" CLEAR 59" NFPA 101-18.2.3.6

NUMBER OF EXITS & EXIT ACCESS

DOORWAYS REQUIRED

2 (IN AREAS WITH MORE THAN 50 OCC.) N/A SECTION 1006

MINIMUM CORRIDOR WIDTH 96" 96" NFPA 101-18.2.3.4

DOOR SWINGS ≥ 50 OCCUPANT = SWING IN DIRECTION OF

TRAVEL

DOORS (multiply by 0.2 inches/occupant) SEE CODE PLANS EXISTING 1005.7.1

STAIRWAYS (multiply by 0.3 inches/occupant - sprinkled throughout)

SEE CODE PLANS EXISTING 1005.3.1

MEANS OF EGRESS SIZING

STORAGE, MECHANICAL 300 GROSS SEE CODE PLANS

CONCENTRATED BUSINESS 50 GROSS SEE CODE PLANS

BUSINESS 150 GROSS SEE CODE PLANS

INPATIENT TREATMENT 240 GROSS SEE CODE PLANS

LIST TYPE LIST FACTOR TOTAL OCCUPANTS TABLE 1004.1.2

OCCUPANCY LOAD - FUNCTION OF SPACE

(LIST BELOW)

OCCUPANT LOAD FACTOR

MEANS OF EGRESS IBC CHAPTER 10

NFPA/IBC REQUIRED ACTUAL PROVIDED 3/3

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ARCHITECT OF RECORD

A/E:

STAMPCONSULTANTS

o n e e ig h th in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s in c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h e s o n e f o o t th re e in c h e s o n e f o o t

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

MECHANICAL / ELECTRICAL / PLUMBING: STRUCTURAL:HEALTHCARE ARCHITECT:

2550 UNIVERSITY AVE. W. SUITE 423-S

ST. PAUL, MN 55114

651.251.7570

50 SOUTH 6TH ST UNIT 1100

MINNEAPOLIS, MN 55402

612.465.7550

380 ST. PETER ST. UNIT 600

ST. PAUL, MN 55102

651.222.3701

C U s e rs

\T .L a rs o n \D o c u m e n ts

\2

M D

I n

P a t

B T a n n e rL

N

S

C .r v t

/1

/2

:5

:5

A

M

GI103

LIFE SAFETY CODE REVIEW

Stone Group Architects

600 E 7th Street

Sioux Falls, SD 57103

605-271-1144

RENOVATE INPATIENT WARD - 7B

2500 OVERLOOK TERRACE, MADISON, WI 53705

05/17/2024 JHK / IEP TDL

100% CONSTRUCTION

DOCUMENTS

SGA #231919

FEC

FEC

S D

DN

DN

F E

DN

FE

A. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION

DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE OWNER

BEFORE PROCEEDING WITH THE WORK.

B. SMOKE SEALS ON ALL RATED DOORS.

C. SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION.

D. DAMPERS ARE NOT REQUIRED IN DUCT PENETRATIONS OF SMOKE BARRIERS WHERE HVAC

SYSTEMS ARE FULLY DUCTED. (NFPA 101-18.3.7.3(2)).

E. AIR TRANSFER OPENINGS IN SMOKE PARTITIONS SHALL HAVE DAMPERS (NFPA 101-8.2.4.4.3)

(IBC 710.7).

F. SMOKE DAMPERS ARE NOT REQUIRED WHERE OPENINGS IN DUCT ARE LIMITED TO A SINGLE

SMOKE COMPARTMENT & DUCTS ARE MADE OF STEEL (IBC 716.5.5).

G. TRANSFER GRILLES ARE NOT ALLOWED IN CORRIDOR WALLS OR DOORS WITHOUT

EXCEPTION. (NFPA 101-18.3.6.4.1).

GENERAL CODE PLAN NOTES:

215 SF

B7098

PATIENT RM

B7098A

PAT TLT

B7094A

PAT TLT

216 SF

B7094

PATIENT RM

73 SF

B7060

ASSIST

NURSE

MANGER

1 2

4 8

144 SF

B7087

CLEAN

UTILITY

301 SF

B7095

EQUIP.

STORAGE

4 3

252 SF

B7099

BREAK /

CONF

78 SF

B7099A

LOCKER

151 SF

B7093

SHARED

EPI/PM&R

B7097

STAFF TLT

181 SF

B7089

PATIENT RM

B7089A

PAT TLT

54 SF

B7091

CLEAN

LINEN

111 SF

B7081B

CONSULT

66 SF

B7085

NOURISH

476 SF

B7081

NURSE

STATION

79 SF

B7081A

MEDS

100 SF

B7077

NURSE

MANAGER

B7071A

PAT TLT

82 SF

B7073

SOILED

UTILITY

209 SF

B7071

PATIENT RM

236 SF

B7069

BARI

PATIENT RM

B7065A

PAT TLT

B7069A

PAT TLT

232 SF

B7065

EPI/BARI

PATIENT RM

164 SF

B7063A

ISO PATIENT

RM

B7063B

PAT TLT

78 SF

B7061

PT

TREATMENT

B7063

ANTE

B7062

ANTE

174 SF

B7062A

ISO PATIENT

RMB7062B

PAT TLT

155 SF

B7059

HSKPG

215 SF

B7064

PATIENT RM

B7064A

PAT TLT

B7068A

PAT TLT

216 SF

B7068

PATIENT RM

216 SF

B7070

PATIENT RM

B7074B

PAT TLT

B7070A

PAT TLT

166 SF

B7074A

ISO PATIENT

RM

166 SF

B7076A

ISO PATIENT

RM

B7076B

PAT TLT

B7080A

PAT TLT

216 SF

B7080

PATIENT RM

216 SF

B7082

PATIENT RM

215 SF

B7086

EPI PATIENT

RM 215 SF

B7088

EPI PATIENT

RMB7086A

PAT TLT

B7082A

PAT TLT

B7092A

PAT TLT

B7088A

PAT TLT

215 SF

B7092

PATIENT RM

B7121F

ELEC

B7121D

ELEC

75'-0"

75'-0"

LENGTH OF TRAVEL: 81'-3"

LENGTH OF TRAVEL: 93'-1"

LENGTH OF TRAVEL: 91'-1"

7.0"

39.0"

6.2"

43.0"

10.34

22.0522.05

22.05

75'-0"

75'-0"

FE

LEGEND

BUILDING & LIFE SAFETY REQUIREMENTS

DESCRIPTION

WALL

RATING

NEW

PARTITION KEY

NFPA

101-2021

OPENINGS DAMPERS

RATING RFRNC. TYPE RFRNC.

BUILDING SEPARATION:

FIRE BARRIER

90 MIN

OCCUPANCY/AREA SEPARATION

FIRE BARRIER

2 HR

90 MIN

HORIZONTAL EXIT (& REFUGE AREA)

FIRE BARRIER

90 MIN

VERT. OPG. (EXIT ENCLSR/SHAFT)

FIRE BARRIER

(2 HR = 4 OR MORE STORIES)

(1 HR = LESS THAN 4 STORIES)1 HR

2 HR

60 MIN

90 MIN

HAZ./INCIDENTAL USE

FIRE BARRIER

45 MIN

HAZ./INCIDENTAL USE

SMOKE PARTITIONS

(SPRINKLERED)

NR-

RESIST

SMK

NR

SELF OR AUTO

CLOSING

SUBDIVIDING SPACES

SMOKE BARRIER (I-2 OCCUPANCY)

20 MIN

SUITE SEPARATION

SMOKE PARTITION

NR

*NR

SELF OR AUTO

CLOSING

EXIT ACCESS CORRIDORS (I-2)

SMOKE PARTITIONS (SPRINKLERED)

NR-

RESIST

SMK

NR

EXIT ACCESS CORRIDORS (B & AHC)

NON-RATED PARTITIONS

NR

NR

VERT. OPG. (SHAFT)

FIRE BARRIER 60 MIN

1 HR

2 HR

60 MIN

90 MINEXIT PASSAGEWAY (HORIZ.)

FIRE BARRIER

6.1.14.4.1

7.1.3.2

8.7.1.1

8.5

8.4.2

8.4.2

21.3.6

7.2.6

8.2.1.3

8.6

8.6

8.7.1.2

8.3.3.2.2 TBL

8.3

8.3.3.2.2 TBL

8.3 8.7.1.1

8.3.3.2.2 TBL

19.3.7.8

8.3.3.2.2 TBL

8.3

8.3.3.2.2 TBL

8.3

8.3.3.2.2 TBL

8.3

8.3.3.2.2. TBL

8.3

8.3.3.2.2TBL

8.7.1.2

8.3.3.2.2 TBL

8.4

8.4.3

N/A

FIRE

90 MIN

FIRE

90 MIN

FIRE

90 MIN

NOT

ALLOWED

UNLESS

SERVING

STAIR ONLY

N/A

VARIES

SMOKE

90 MIN

VARIES

VARIES

NONE

N/A

NOT

ALLOWED

8.3.4.8 9.2.1

8.3.4.8 9.2.1

8.3.4.8 9.2.1

N/A

8.5.5.3

8.6.4

N/A

N/A

8.4.4

8.4.4 8.4.6.2

8.4.4 8.4.6.2

N/A

8.3.3.2.2 TBL

8.3

1 HR

1 HR

2 HR

1 HR

CODE PLAN LEGEND

0.0"

0.0"

OCCUPANTS

REQUIRED WIDTH

PROVIDED WIDTH

OCCUPANT LOAD

FEC FIRE EXTINGUISHER CABINET

STAIR

STAIR

B7000

TELECOM

ROOM

NORTH

KEY PLAN - OVERALL

2928 SF

B9030

PENTHOUSE

- EAST

8.2"

34.0"

75'-0"

75'-0"

75'-0"

5.31

5.43

B9001A

TELECOM

ROOM

143 SF

B9001

MECHANICAL

ROOM

2807 SF

B9004

STAIR 3

1/8" = 1'-0" D3

7TH LEVEL CODE PLAN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ARCHITECT OF RECORD

A/E:

STAMPCONSULTANTS

o n e e ig h th in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s in c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h e s o n e f o o t th re e in c h e s o n e f o o t

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

MECHANICAL / ELECTRICAL / PLUMBING: STRUCTURAL:HEALTHCARE ARCHITECT:

2550 UNIVERSITY AVE. W. SUITE 423-S

ST. PAUL, MN 55114

651.251.7570

50 SOUTH 6TH ST UNIT 1100

MINNEAPOLIS, MN 55402

612.465.7550

380 ST. PETER ST. UNIT 600

ST. PAUL, MN 55102

651.222.3701

C U s e rs

\T .L a rs o n \D o c u m e n ts

\2

M D

I n

P a t

B T a n n e rL

N

S

C .r v t

/1

/2

:5

:0

A

M

GI104

LIFE SAFETY PLANS

Stone Group Architects

600 E 7th Street

Sioux Falls, SD 57103

605-271-1144

RENOVATE INPATIENT WARD - 7B

2500 OVERLOOK TERRACE, MADISON, WI 53705

05/17/2024 JHK / IEP TDL

100% CONSTRUCTION

DOCUMENTS

SGA #231919

VA #607-22-101

TRUE

NORTH

PLAN

NORTH

0' 4'-0" 8'-0" 16'-0"

1/8" = 1'-0" B3

PENTHOUSE CODE PLAN

TRUE

NORTH

PLAN

NORTH

0' 4'-0" 8'-0" 16'-0"

KEYNOTES_SGA

Key Value Keynote Text

5.31 SALVAGED ACCESS LADDER REINSTALLED.

5.43 METAL GUARDRAIL - REF. SPECS.

10.34 RESCUE SLED STORAGE CABINET

22.05 FAUCET INTEGRATED EYE WASH STATION - REF. PLUMBING.

PHASING LEGEND

AFFECTED AREA

NOTES:

1. TEMPORARY CONSTRUCTION BARRIERS SHALL BE MIN. 1 HOUR RATED FIRE

BARRIER ASSEMBLY.

2. ALL CEILINGS DISTURBED DURING AFTER-HOURS ABOVE CEILING WORK SHALL BE

RE-INSTALLED, CLEANED UP AND OPERATIONAL PRIOR TO END OF EACH WORK

SHIFT.

3. ALL OPENINGS THROUGH CONCRETE FLOORS (RATED), MUST BE FIRESTOPPED OR

INFILLLED PRIOR TO END OF EACH WORK SHIFT.

4. CONTRACTOR SHALL AT ALL TIMES ENSURE UNINTERRUPTED HEATING, COOLING,

PLUMBING, ELECTRICAL & COMMUNICATIONS SERVICES TO ALL PARTS OF THE

HOSPITAL THAT REMAIN IN SERVICE. ANY PLUMBING PIPING, ELECTRICAL, OR

COMMUNICATIONS SERVICES CONTAINED WITHIN THE PROJECT THAT SERVE PARTS

OF THE HOSPITAL IN SERVICE SHALL BE MAINTAINED IN OPERATING ORDER. ANY

REQUIRED INTERRUPTION OF SERVICES SHALL BE COORDINATED WITH THE

OWNER'S REPRESENTATIVE TO ALLOW MINIMUM INTERFERENCE WITH OWNERS

OPERATION.

5. CORE DRILLING AND/OR NOISE INTERRUPTIONS ARE TO BE COORDINATED WITH THE

VA COR. EFFORTS WILL BE MADE TO ACCOMMODATE STAFF USAGE OF AREAS

DIRECTLY ABOVE, BELOW, OR ALONGSIDE DEMOLITION. CONTRACTOR TO

COORDINATE NECESSARY PHASING WITH VA IN ORDER TO BEST ADDRESS

DISRUPTIONS AND IMPACT TO ADJACENT SPACES.

TEMPORARY CONSTRUCTION BARRIER

EXISTING PARTITIONS

DEMO PARTITION

EXISTING AREA

AFTER-HOURS AFFECTED AREA

5PM-6AM PLUS WEEKENDS & HOLIDAYS ONLY

TEMPORARY UPGRADE OF EXISTING WALL TO 1-HR RATED FIRE BARRIER

STAIR #1

STAIR #2

B7000

TELECOM

ROOM

B8038

PATIENT

ROOM B8034

PATIENT

ROOM

B8032

PATIENT

ROOM

B8028

NEG

ISOLATION

PATIENT

ROOM

B8026

NEG

ISOLATION

PATIENT

ROOM B8022

PATIENT

ROOM

B8020

PROT

ENVIRON

PATIENT

ROOM

B8016

PROT

ENVIRON

PATIENT

ROOM

B8014

PROT

ENVIRON

PATIENT

ROOM

B8010

PROT

ENVIRON

PATIENT

ROOM

B8008

BARIATRIC

PROT

ENVIRON

PATIENT

ROOM

B8004

PROT

ENVIRON

PATIENT

ROOM

B8002

PROT

ENVIRON

PATIENT

ROOM

STAIR

B8001

STAFF

LOUNGE

B8007

VISITOR/STAFF

TOILET

B8009

NOURISHMENT

B8013

NURSE

STATION

B8021

MED PREP

B8019

MED PREP

ALCOVE

B8023

CLEAN

UTILITY

B8027

CLEAN

LINEN

B8033

SOILED

UTILITY

B8035

ELEC

B8039

VISITOR/

STAFF

TOILETB8043

NURSE

STATION

B8050

CORRIDOR

B8057

CLEAN

UTILITY

B8055

MED PREP

B8053

MED PREP

ALCOVE

B8042

CHARTING

B8048

CHARTING

B8046

NEG

ISOLATION

PATIENT

ROOM

B8044

PATIENT

ROOM

B8040

BARIATRIC

PATIENT

ROOM

STAIR #1

STAIR #2

B8065

MECHANICAL

B8063

HKSP

B8000

TELECOM

ROOM

NORTH

KEY PLAN - OVERALL

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ARCHITECT OF RECORD

A/E:

STAMPCONSULTANTS

o n e e ig h th in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s in c h o n e f o o t o n e h a lf in c h o n e f o o t th re e q u a rt e rs in c h o n e f o o t o n e in c h o n e f o o t o n e a n d o n e h a lf in c h e s o n e f o o t th re e in c h e s o n e f o o t

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

MECHANICAL / ELECTRICAL / PLUMBING: STRUCTURAL:HEALTHCARE ARCHITECT:

2550 UNIVERSITY AVE. W. SUITE 423-S

ST. PAUL, MN 55114

651.251.7570

50 SOUTH 6TH ST UNIT 1100

MINNEAPOLIS, MN 55402

612.465.7550

380 ST. PETER ST. UNIT 600

ST. PAUL, MN 55102

651.222.3701

C U s e rs

\T .L a rs o n \D o c u m e n ts

\2

M D

I n

P a t

B T a n n e rL

N

S

C .r v t

/1

/2

:5

:1

A

M

GI110

PHASING PLANS

Stone Group Architects

600 E 7th Street

Sioux Falls, SD 57103

605-271-1144

RENOVATE INPATIENT WARD - 7B

2500 OVERLOOK TERRACE, MADISON, WI 53705

05/17/2024 JHK / IEP TDL

100% CONSTRUCTION

DOCUMENTS

SGA #231919

VA #607-22-101

1/8" = 1'-0" D2

PHASING PLAN - 7TH LEVEL

TRUE

NORTH

PLAN

NORTH

TRUE

NORTH

PLAN

NORTH

1/8" = 1'-0" B2

PHASING PLAN - 8TH LEVEL

HAZARDOUS MAT. LEGEND

*MATERIALS CONTAINING LESS THAN 1% ASBESTOS ARE NOT REQUIRED BY NESHAP OR AHERA;

HOWEVER THE OSHA PERSONAL EXPOSURE LIMITS (0.1 f/cc OF AIR AS AN EIGHT HOUR TIME WEIGHTED AVERAGE OR 1.0 f/cc OF AIR OVER 30 MINUTES) FOR ASBESTOS APPLY WHEN MATERIALS

CONTAINING 1% ASBESTOS OR LESS ARE DISTURBED DURING RENOVATIONS OR DEMOLITIONS.

REFERENCE ASBESTOS SURVEY FOR A LIST OF MATERIALS THAT CONTAIN 1% ASBESTOS OR LESS

WHICH WILL ENABLE THE RENOVATION/DEMOLITION CONTRACTOR TO MAKE APPROPRIATE

DECISIONS CONCERNING COMPLIANCE ISSUES WITH APPLICABLE OSHA REGULATIONS

APPROXIMATE QUANTITIES

ASBESTOS CONTAINING

PIPING WRAPS

156 L.F.

SCOPE OF WORK LEGEND

SHADED AREA NOT IN SCOPE OF WORK

A. REMOVE ALL ASBESTOS PIPE FITTING INSULATION WITHIN THE ASBESTOS ABATEMENT WORK

SPACE, ABOVE AND BELOW CEILINGS AND IN THOSE CHASES SCHEDULED FOR DEMOLITION.

REMOVE ALL DEBRIS FOUND IN THE WORK AREA. USE TRADITIONAL ASBESTOS ABATEMENT

METHODS IN THOSE AREAS WHERE INSULATION MAY BE DAMAGED AND SIGNIFICANT PORTIONS OF DEBRIS MAY EXIST. CHASE WALLS SHALL BE REMOVED USING TRADITIONAL ASBESTOS ABATEMENT

TO PRECLUDE ANY POSSIBLE RELEASE OF MATERIAL INTO THE AREA DUE TO DEMOLITION

ACTIVITIES.

B. REMOVE AND REPLACE WITH NEW ANY PLUMBING/MECHANICAL SYSTEM THAT IS TO REMAIN IN USE. REFER TO MECHANICAL DRAWINGS AND SPECIFICATIONS. PLUMBING/MECHANICAL SYSTEMS

TO BE PERMANENTLY REMOVED, MAY BE CUT AND WRAPPED AND REMOVED IN SECTIONS WITH

THE INSULATION STILL ATTACHED.

C. ENCAPSULATE THE EXPOSED ENDS OF ANY PIPE INSULATION THAT ARE NOT REMOVED AT

ADJOINING FLOOR LEVELS.

D. SEE SPECIFICATIONS SECTIONS 028211 & 028213-19 FOR ASBESTOS ABATEMENT AND ASBESTOS

SURVEY.

GENERAL HAZARDOUS MATERIALS NOTES:

C

D

E

G

29282726252423222120191817

NORTH

KEY PLAN - OVERALL

B7088

HOUSEKEEPING

B7087

STORAGE

B7086

ADA

PATIENT

ROOM

B7085

PATIENT

ROOM

B7084

PATIENT

ROOM

B7083

BAR.

PATIENT

ROOM

B7082

SOILED

UTILITY

B7081

CLEAN

LINEN

B7080

CLEAN

UTILITY

B7079

MED PREP

B7078

NURSE

STATION

B7077

CONSULTANTS

ROOM

B7076

NOURISHMENT

B7075

LOCKERS

B7074

EQUIPMENT

ROOM

B7073

OFFICE

B7072

PM & R

ROOM

B7071

EPILEPSY

MONITOR

LAB

B7070

EPI PATIENT

ROOM

B7069

EPI PATIENT

ROOM

B7068

EPI/BAR

PATIENT

ROOM

B7067

PATIENT

ROOM

B7066

ADA

PATIENT

ROOM

B7065

ADA

PATIENT

ROOM

B7064

PATIENT

ROOM

B7063

PATIENT

ROOM

B7062

ADA

PATIENT

ROOM

B7061

ADA

PATIENT

ROOM

B7060

PATIENT

ROOM

B7059

OFFICE

B7058

OFFICE

B7057

ORTHO

RESIDENTS

B7121

CORRIDOR

B7121

CORRIDOR

B7…