S02 Drawings FH Storage Pad 27Sep.pdf
PDF 3 MB Posted
- Attached to
- Z1DA--36C26125R0024 | 36C261-25-AP-0208 | VASNHS Concrete Pad, Fisher House Storage, Bldg. 8 | PM | 593
- Solicitation number
- 36C26125R0024
About this file
This is a set of construction drawings for building a concrete storage pad at the Southern Nevada Healthcare System Fisher House Building 8 (Project #593-24-101). The drawings detail the construction of a 40' x 48' reinforced concrete pad with connecting driveway to Parking Lot G and existing Fisher House walkway, designed to support a 40'L x 8'W x 9.5'H storage container.
The drawings include detailed site plans, construction details, and electrical specifications. Key specifications include 6" thick reinforced concrete with 4500 PSI strength using Type V cement, new concrete walkways with broomed finish, aluminum screen walls and gates to be installed after concrete completion, and electrical components including a 125A electrical panel, GFCI outlets, LED lighting, and PTAC units. The project location is at 6900 N Pecos Rd, North Las Vegas, NV, near the Bruce Woodbury Beltway. The drawings are dated September 27, 2024 and consist of 5 sheets covering the site plan, storage location, plan details, fence details, and electrical plans.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C26125R0024 0003.docx | DOCX document | |
| S04 Site Walk Sign In Sheet Concrete 20250211.pdf | ||
| 36C26125R0024 0002.docx | DOCX document | |
| 36C26125R0024 0001.docx | DOCX document | |
| S02 WD NV20250038 rev 20250124.pdf | ||
| S02 Specs Complete 20241206 Fisher House Storage Concrete.pdf | ||
| S02 Price Breakdown by Division sheet 36C26125R0024 Concrete.pdf | ||
| S02 EMR Sheet 2025.pdf | ||
| S02 VASNHS Site Map.pdf | ||
| 36C26125R0024.docx | DOCX document | |
| S02 RFI Form 36C26125R0024 Concrete.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NORTH
SHEET INDEX
SHEET 1 OF 5 COVER SHEET AND SHEET
INDEX
SOUTHERN NEVADA HEALTHCARE SYSTEM
CONSTRUCT FISHER HOUSE STORAGE PAD
AREA MAP
BRUCE WOODBURY BELTWAY
BRUCE W
OODBURY BELTW
AY
I-15
E TROPICAL PKWY
E AZURE AVE
CENTENNIAL PKWY
N P
EC
O
S R
D
N L
AM
B
BL
VD
LO
SE
E R
D
PROJECT LOCATION
CAMPUS MAP
SHEET 2 OF 5 STORAGE LOCATION AND
PLAN VIEW
PROJECT NUMBER: 593-24-101
CONSTRUCTION DOCUMENTS
SHEET 3 OF 5 PLAN DETAILS
SHEET 4 OF 5 FENCE DETAILS
Construct Fisher House Storage Pad
Cover Sheet
NTS
593-24-101
SHEET 5 OF 5 ELECTRICAL PLAN & DETAILS
1 527 SEP 2024
Drawing Title
Approved: Chief, Engineering Service
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. of
Revisions: DateEngineering Service
Scale:
North Las Vegas, NV
JS BB
Approved: VA Medical Center Director
Jonathan G. SanchezWilliam J. Caron, MHA, PT, FACHE
S:\FMS\06 Projects\Projects Staff Folders\0_PROJECTS ACTIVE\593-24-101 Construct Fisher House Storage\II. CONSTRUCTION\01 CONTRACT DOCUMENTS\b. Procurement Package\7. Drawings\FH Storage Pad location 27Sep.dwg, 9/27/2024 10:41:09 AM
FH
FH
FISHER HOUSE
BLDG #8
PARKING LOT
G
SCALE = FEET
0 50 10010 20 30 40
NEW CONCRETE WALKWAY
NEW OPENING AT
EXISTING FENCE
EXISTING SWALE
INVERT FLOW LINE
106'
23'
49'
SLOPE
TO DRAIN
EXISTING
IRRIGATION
BOXES
EXISTING FENCE LINE
7'
33'
25'
7'
EXISTING
ASPHALT
EXISTING CONCRETE WALKWAY
6'
75'
2% SLO
PE
MATCH
EXISTING
ELEV 0.0'
6'
EXISTING
GATE
48'
40' LONG X
8' WIDE STORAGE
CONTAINER
BY OTHERS
BACKFILL EXISTING SWALE WITH
CLASS 2 AB, FINISH GRADE AREA
TO SLOPE AWAY FROM CONCRETE PAD
UG ELECTRICAL
CONDUITS
BY OTHERS
NEW
CONCRETE
WALKWAY
NEW CONCRETE
DRIVEWAY
40'
48'
SCALE = FEET
0 5010 20 30 40
5'
G
E
H
3'
CONSTRUCTION NOTES:
1. PROTECT EXISTING UTILITIES TO REMAIN DURING AND/OR AFTER CONSTRUCTION.
2. CONCRETE MINIMUM COMPRESSIVE STRENGTH OF 4500 PSI AT 28 DAYS WITH TYPE V CEMENT.
3. REINFORCED CONCRETE PAD AND WALKWAY SHALL BE 6" THICK MINIMUM.
4. (NOT IN CONTRACT) ASTM A615 GRADE 60 STEEL REINFORCEMENT BAR #3 @ 24" O.C. EACH WAY.
5. PROTECT ALL REBAR IN POSITION PRIOR TO PLACING CONCRETE.
6. (NOT IN CONTRACT) PLACE 10 MIL VAPOR BARRIER AFTER VA APPROVAL OF STRUCTURAL FILL COMPACTION. OVERLAP
VAPOR BARRIER TO BE 6" MINIMUM. SEAMS SHALL BE COVERED WITH COMPATIBLE 4" WIDE TAPE MINIMUM.
7. (NOT IN CONTRACT) PLACE 2" THICK SAND ABOVE AND BELOW THE VAPOR BARRIER.
8. (NOT IN CONTRACT) TAKE OUT ANY EXISTING PLANTS ON THE FOOT PRINT OF NEW CONCRETE WALKWAY AND MODIFY
EXISTING DRIP IRRIGATION. PROTECT PLANTS AND IRRIGATION TO REMAIN.
9. IMMEDIATELY NOTIFY COR IN WRITING OF ANY CONFLICT BETWEEN THE PLANS AND EXISTING SITE CONDITION.
H
A
40'x8' STORAGE CONTAINER
BY OTHERS
GOLF CART
CHARGING
STATION
' T
YP
F
J
8'
13'
8'
OPENING
I
7'
25'
B
MATCH
EXISTING
ELEV 0.0'
NEW ELEV 2.0' NEW ELEV 2.0'
MATCH
EXISTING
ELEV. 1.5'
.5
LEGEND
A - PROTECT EXISTING FENCE LINE
B - PROTECT EXISTING BENCHMARK
C - NEW 6" THICK REINFORCED CONCRETE - BROOMED FINISH
D - (NOT IN CONTRACT)12" DIA X 36" DEEP CONCRETE FORM SONATUBE @ 4 LOCATIONS TYP.
E - (NOT IN CONTRACT) 8' HIGH ALUMINUM SCREEN WALL TO BE INSTALLED AFTER CONCRETE PAD COMPLETION F - (NOT IN CONTRACT) 2" DIA PVC WITH UFER GROUND - #4 AWG SOLID COPPER WIRE - SEE PLAN DETAIL 8
G - (NOT IN CONTRACT) ELECTRICAL PULLBOX - SEE PLAN DETAIL 7
H - (NOT IN CONTRACT) ALUMINUM GATES WITH CANE BOLTS TO BE INSTALLED AFTER CONCRETE PAD COMPLETION I - (NOT IN CONTRACT) ELEC PULLBOX WITH 8' COPPER GROUND ROD AND #4 AWG SOLID COPPER WIRE J - (NOT IN CONTRACT) UG ELECTRICAL PATHWAY WITH 2EA - 2" RGC ABOVEGROUND FROM PULLBOX TO
STORAGE ELECTRICAL PANEL OUTSIDE ACCESS AND 2" SCH 40 PVC UG WITH
4EA-1/0 AWG WITH #1AWG GROUND WIRE. ENCASE IN 2000 PSI RED DYE CONCRETE.
K - NEW 6" THICK CONCRETE WALKWAY - BROOMED FINISH
X
C
A
C
C
D
E
NEW ELEV 2.0'
NEW ELEV 2.0'
K
75'
FH Storage Location and Plan View
Graphic Scale Bar
Construct Fisher House Storage Pad
NORTH
NORTH
PLAN VIEW
LOCATION PLAN
593-24-101
2 527 SEP 2024
Drawing Title
Approved: Chief, Engineering Service
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. of
Revisions: DateEngineering Service
Scale:
North Las Vegas, NV
JS BB
Approved: VA Medical Center Director
Jonathan G. SanchezWilliam J. Caron, MHA, PT, FACHE
S:\FMS\06 Projects\Projects Staff Folders\0_PROJECTS ACTIVE\593-24-101 Construct Fisher House Storage\II. CONSTRUCTION\01 CONTRACT DOCUMENTS\b. Procurement Package\7. Drawings\FH Storage Pad location 27Sep.dwg, 9/27/2024 10:52:04 AM
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
#3 REBAR
@ 24" O.C. EW (NIC)
CLASS 2 AB (NIC)
4,500 PSI AIR-ENTRAINED
CONCRETE SLAB, BROOMED
FINISH (TYP.)
CLASS 2 AB (NIC)
COMPACTED SUBGRADE
(NIC)
EXISTING ASPHALT
FIBRE EXPANSION JOINT (NIC)
#3 @ 24" O.C. EW (NIC)
SLOPE
12"
12"
3"
2" DIA DUCT
NOTES:
1. MINIMUM COVER TO TOP OF ENVELOPE SHALL BE 24".
2. RED DYED CONCRETE ENCASEMENT SHALL BE 2000 P.S.I. @ 28 DAYS.
3. PROVIDE PLASTIC PULL ROPE WITH 200 LBS MIN TENSILE STRENGTH IN
SPARE DUCT.
4. NOT IN CONTRACT; TO BE INSTALLED BY OTHERS.
3"
3"
PLASTIC SPACERS
@ 10' O.C.
" M
IN
3" WIDE DETECTABLE TAPE
@ 18" ABOVE CONCRETE
ENCASEMENT
GRAVEL FINISH GRADE
12"
EXISTING
CONCRETE
WALKWAY
NEW CONCRETE WALKWAY
FIBRE EXPANSION JOINT (NIC)
SAWCUT ASPHALT (NIC)
SEALANT (NIC)
BOND BREAKER TAPE (NIC)
PVC CAP (NIC)
EXPANSION MATERIAL (NIC)
3/8" EXPANSION JOINT (NIC)
CORNER EDGE
R 1/4" TYP.
#4 X 18" SS GREASED DOWEL
@ 24" O.C. (NIC) CONTROL JOINTS
(TYP)
1" TYP.
3/8" EXPANSION JOINT (NIC)
1/8" WIDE SAW CUT
CONTROL JOINT
NOTE:
1. JOINT DEPTH SHALL BE 1/4 OF THICKNESS OF CONCRETE PAD.
SEE DETAILS KEY PLAN FOR LOCATION.
4" THICK GRAVEL TO
MATCH EXISTING (NIC)
NOTE:
1. PULLBOX - UG BOX WITH COVER, ELECTRICAL GRAY
BOX 14" W X 19" L X 12" D.
2. NOT IN CONTRACT; TO BE INSTALLED BY OTHERS.
NOTE:
1. UFER GROUND AND GROUND ROD
2. REBAR SHALL NOT BE USED AS A CONDUCTOR TO INTERCONNECT THE
ELECTRODES OF GROUNDING ELECTRODE SYSTEM.
3. NOT IN CONTRACT; TO BE INSTALLED BY OTHERS.
1'6
#3 @ 24" O.C. EW (NIC)
#4 X 18" SS GREASED DOWEL
@ 24" O.C. (NIC)
NON-METALLIC PROTECTIVE SLEEVE
BOLTED TYPE CONNECTION DEVICE
OR EXOTHERMIC WELD
2'-5"
8'-0
20 FT MIN. GROUNDING
ELECTRODE NO. 4 OR
LARGER BARE CONDUCTOR
PULLBOX
CONCRETE BRICKS
4EA - 2" X 8" X 16"
CLEAN 34" CRUSHED ROCK
GRADE, FEATHER & TAMP BACKFILL
TO CREATE FLUSH INSTALLATION
AND POSITIVE DRAINAGE AWAY FROM BOX
CONDUIT(S) WITH BELL ENDS (TYP)
SIZE, QUANTITY AND WIRING AS
INDICATED ON PLANS
12"
TO PULLBOX
TO FH STORAGE
ELEC PANEL
Plan Details
Not To Scale
Construct Fisher House Storage Pad
DETAILS KEY PLAN
SCALE:NTS
PLAN DETAIL 1
SCALE:NTS
PLAN DETAIL 2
SCALE:NTS
PLAN DETAIL 3
SCALE:NTS
PLAN DETAIL 4
SCALE:NTS
PLAN DETAIL 5 (NIC)
SCALE:NTS
PLAN DETAIL 6
SCALE:NTS
PLAN DETAIL 7 (NIC)
SCALE:NTS
PLAN DETAIL 8 (NIC)
SCALE:NTS
3 527 SEP 2024
593-24-101
NORTH
Drawing Title
Approved: Chief, Engineering Service
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. of
Revisions: DateEngineering Service
Scale:
North Las Vegas, NV
JS BB
Approved: VA Medical Center Director
Jonathan G. SanchezWilliam J. Caron, MHA, PT, FACHE
S:\FMS\06 Projects\Projects Staff Folders\0_PROJECTS ACTIVE\593-24-101 Construct Fisher House Storage\II. CONSTRUCTION\01 CONTRACT DOCUMENTS\b. Procurement Package\7. Drawings\FH Storage Pad location 27Sep.dwg, 9/27/2024 10:53:28 AM
56'
73'
2'
1'
40' L x 8' W x 9.5' H STORAGE CONTAINER
SONATUBE INSTALLED BY OTHERS
BEFORE CONCRETE POUR (4 ea TYP)
1'5'-2"
5 1/2"
6"
8'
3' 2'
3"
NOTE(S):
1. 17 EACH PER PANEL- 5.5" SLAT 6' LONG WITH 1/2" SPACERS.
2 3/4" X 2 3/4" X 8' ALUMINUM POST
1 1/4" X 1 1/4" X 10' SQUARE STEEL (A513) TUBE
2 3/4" X 2 3/4" POST CAP
5 1/2" X 7/8" X 6' ALUMINUM SLAT
1" X 1/2" X 1/4" ALUMINUM SPACERS
TYPE V CEMENT CONCRETE FOOTING
6'-2"
GATE FRAME WITH CAP (TYP)
8'
3' 2'
SIDE POST WITH CAP (TYP)
SELF CLOSING HINGE
6 EA PER GATE (TYP)
3"
1'
GRAVEL
FINISH
GRADE
23'
6'10'3' 1' 3'
12" BLACK CANE BOLT
4 EACH (TYP)
DOOR LOCK (SATIN CHROME)
WITH INTERCHANGEABLE CORE
A KEYWAY - 7 PINS
(FALCON T561BDCD26 OR
APPROVED EQUAL)
STORAGE CONTAINER (NIC)
Drawing Title
Approved: Chief, Engineering Service
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. of
Revisions: DateEngineering Service
Scale:
North Las Vegas, NV
JS BB
Approved: VA Medical Center Director
Jonathan G. SanchezWilliam J. Caron, MHA, PT, FACHE
Plan Details
NTS
Construct Fisher House Storage Pad
DETAILS KEY PLAN
SCALE:NTS
PLAN DETAIL 9 (NIC)
SCALE:NTS
PLAN DETAIL 10 (NIC)
SCALE:NTS
4 527 SEP 2024
593-24-101
NORTH
S:\FMS\06 Projects\Projects Staff Folders\0_PROJECTS ACTIVE\593-24-101 Construct Fisher House Storage\II. CONSTRUCTION\01 CONTRACT DOCUMENTS\b. Procurement Package\7. Drawings\FH Storage Pad location 27Sep.dwg, 9/27/2024 10:54:32 AM
GFCI
GOLF CART
CHARGING
STATION
S
125A ELEC PANEL
2EA LED T8 BULBS
(4EA TYP)
PT
A C
UFER GROUND
8' COPPER
GROUND ROD
Drawing Title
Approved: Chief, Engineering Service
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. of
Revisions: DateEngineering Service
Scale:
North Las Vegas, NV
JS BB
Approved: VA Medical Center Director
Jonathan G. SanchezWilliam J. Caron, MHA, PT, FACHE
Plan Details
NTS
Construct Fisher House Storage Pad
PANEL SCHEDULE
(NIC)
ELECTRICAL PLAN (NIC)
SCALE:NTS
5 527 SEP 2024
593-24-101
PANEL NAME: FISHER HOUSE STORAGE
VOLTAGE/PHASE/AMP
208 / 120-3PH-125A
PANEL LOCATION
STORAGE CONTAINER (INSIDE)
SOURCE / LOCATION
PANEL DB1 / OUTSIDE ELECTRICAL PAD
CKT
LOAD DESCRIPTION LOAD DESCRIPTION
CKT
INTERIOR LIGHTS
PTAC UNIT
PTAC UNIT
OUTDOOR GFCI RECEPTACLE
INTERIOR RECEPTACLE
OUTDOOR LIGHTS
CKT-4
CKT-2
CKT-1
CKT-3/5
CKT-6
PANEL "DB1" (NEMA 3R)
NIC
400A 3P
500A 3P
"ATS1"
20A 2P
NEW
125A 3P
NEW
125A 3P
400A 3P
FISHER HOUSE
ELEC PANEL
PARKING
LOT LIGHTS
SPARE
125A 3P
NEW FISHER HOUSE
STORAGE CONTAINER
ELEC PANEL
600A, 120/208V, 3/0, 4W
NORTH
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
S:\FMS\06 Projects\Projects Staff Folders\0_PROJECTS ACTIVE\593-24-101 Construct Fisher House Storage\II. CONSTRUCTION\01 CONTRACT DOCUMENTS\b. Procurement Package\7. Drawings\FH Storage Pad location 27Sep.dwg, 9/27/2024 10:55:24 AM
| Sheets and Views |
| Cover Sheet |
| FH Storage Pad location 27Sep-Location Plan.pdf |
| Sheets and Views |
| Location Plan |
| FH Storage Pad location 27Sep-Plan Details.pdf |
| Sheets and Views |
| Plan Details |
| FH Storage Pad location 27Sep-Fence Details.pdf |
| Sheets and Views |
| Fence Details |
| FH Storage Pad location 27Sep-Electrical Plan.pdf |
| Sheets and Views |
| Electrical Plan |
File details come from the government source that posted it. Updated .