S02. Drawings - Safety and Security.pdf
PDF 15 MB Posted
- Attached to
- Y1NB--Renovate Operating Rooms - VAMC Cleveland
- Solicitation number
- Amend0002
About this file
This amendment to a federal solicitation provides additional drawings for a renovation project. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10 seeks to renovate operating rooms at the VAMC Cleveland medical center. The purpose of amendment 0002 is to add all drawings related to safety and security considerations for the operating room renovation project. The bid opening date remains September 9, 2020 at 12:00 PM EST, with all other terms of the original solicitation remaining the same. The amendment provides supplemental drawings to inform bids for the operating room renovation at the specified VA medical center location.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| S02. Drawings - Structural.pdf | ||
| S06. 36C25020B0022 Amend 0002.docx | DOCX document | |
| S02. Drawings - Plumbing.pdf | ||
| S02. Drawings - Mechanical.pdf | ||
| S02. Drawings - Fire Protection.pdf | ||
| S02. Drawings - Medical Gas.pdf | ||
| S02. Drawings - Architectural.pdf | ||
| S02. Drawings - Technology.pdf | ||
| S02. Drawings - Electrical.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECURITY SYSTEM LEGEND
SECURITY CONTROL PANEL - SURFACE MOUNTED
SDP = LENEL SECURITY PANEL
SECURITY CAMERA - FIXED DOME CAMERA CEILING MOUNTED. VARIFOCAL, 80º - 22º VIEWING ANGLE RANGE, NETWORK- ENABLED, 1280 X 800 (1MP) RESOLUTION, H.264 VIDEO COMPRESSION, 30 FRAMES PER SECOND, TAMPERING ALARM, POWER OVER ETHERNET, PROGRESSIVE SCAN, TAMPER RESISTANT CASING. PROVIDE DROP CEILING MOUNTING ACCESSORIES TO MOUNT DOME FLUSH WITH CEILING. DIRECTIONAL ARROW(S) INDICATE GENERAL DIRECTION OF CAMERA'S FIELD OF VIEW.
SECURITY SYSTEM - DURESS-PANIC ALARM PUSHBUTTON - MOUNTED TO UNDERSIDE OF DESK/COUNTER. VERIFY EXACT LOCATION WITH VA POLICE PRIOR TO ROUGH-IN. FURNISHED AND CONNECTED BY CONTRACTOR.
CARDER READER - PROVIDE CARD READER AT ALL ACCESS CONTROLLED DOORS. REFER TO DETAILS FOR TYPICAL INSTALLATION REQUIREMENTS. INSTALL CARD READER AT LOCATION SHOWN IN LIEU OF TYPICAL DETAILS WHEN SHOWN ON
PLANS.
ACCESS CONTROLLED DOOR TYPE 1 - SINGLE DOOR WITH ELECTRIFIED LOCKSET AND HARD-WIRED CARD READER. REFER
TO "ACCESS CONTROLLED DOOR TYPE 1 DETAIL".
ACCESS CONTROLLED DOOR TYPE 2 - DOUBLE DOOR (DOUBLE EGRESS) WITH AUTOMATIC DOOR OPERATOR, HARD-WIRED CARD READER, PUSH PLATES, REQUEST-TO-EXIT MOTION SENSOR, AND MAGNETIC LOCKS. REFER TO "ACCESS CONTROLLED
DOOR TYPE 2 DETAIL".
ACCESS CONTROLLED DOOR TYPE 3 - DOUBLE DOOR (WITH INACTIVE LEAF) WITH HARD-WIRED CARD READER, AUTOMATIC DOOR OPERATOR, PUSH-TO-EXIT BAR, REQUEST-TO-EXIT MOTION SENSOR, AND ELECTRIFIED LOCKSET. REFER TO "ACCESS
CONTROLLED DOOR TYPE 3 DETAIL".
D1
D2
PA
PROVIDE MINIMUM SIZE BACK BOX AS REQUIRED FOR ALL OF THE ABOVE SECURITY DEVICES AND INSTALL IN 3/4"C MINIMUM
COMPLETE CONDUIT SYSTEM TO JUNCTION BOX ABOVE FINISHED CEILING.
REFER TO SPECIFICATIONS DIVISION 28 FOR FURTHER DETAILS REGARDING THE SECURITY SYSTEM.
MOUNT DEVICES AT MOUNTING HEIGHTS LISTED ABOVE UNLESS OTHERWISE NOTED ON THE FLOOR PLANS. COORDINATE EXACT
MOUNTING LOCATION WITH ARCHITECTURAL ELEVATIONS.
ALL SECURITY SYSTEM ROUGH-INS, CONDUIT, WIRING AND EQUIPMENT/DEVICES SHALL BE PROVIDED BY CONTRACTOR.
CONTRACTOR SHALL VERIFY ALL BACKBOX SIXES WITH VA COR AND MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO
ROUGH-IN.
FURNISH, INSTALL AND CONNECT ALL SECURITY DEVICES IN ACCORDANCE WITH LENEL SYSTEM. PROVIDE ALL ADDITIONAL LENEL COMPONENTS AS NECESSARY FOR A COMPLETE SYSTEM. SUBMIT ALL LENEL DEVICES WITH SHOP DRAWINGS SUBMITTAL
CR
D3
S1.
S2.
S3.
S4.
S5.
S6.
SECURITY SYSTEM NOTES:
FIRE ALARM SYSTEM
F
F
F
RS
CM
MM
TS
FS
FIRE ALARM SYSTEM NOTES:
ALL FIRE ALARM SYSTEM DEVICES SHALL BE CONNECTED COMPLETE TO THE MAIN FIRE ALARM SYSTEM CONTROL PANEL IN ACCORDANCE WITH ENGINEER APPROVED MANUFACTURER'S SHOP DRAWING WIRING DIAGRAMS AND DETAILS. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING A FULLY CODE COMPLIANT FIRE ALARM SYSTEM. DEVICES SHOWN ON PLAN ARE FOR
REFERENCE ONLY.
PROVIDE A 2-GANG MINIMUM SIZE BACKBOX FOR ALL OF THE ABOVE FIRE ALARM DEVICES.
ALL FIRE ALARM SYSTEM CONDUCTORS SHALL BE INSTALL IN 3/4" MINIMUM SIZE COMPLETE CONDUIT SYSTEM WITH COLOR
CODED WIRING AS INDICATED ON SHOP DRAWINGS - MAINTAIN FACILITY COLOR CODING.
ALL NETWORK AND NETWORK CABLES SHALL BE "COMMUNICATION GRADE" TYPE CABLE.
FURNISH, INSTALL AND CONNECT ALL FIRE ALARM DEVICES IN ACCORDANCE WITH WIRING DIAGRAMS PREPARED BY SYSTEM
VENDOR.
EXISTING FIRE ALARM SYSTEM BY NOTIFIER. REFER TO SPECIFICATIONS SECTION 283100 FOR ELECTRICAL REQUIREMENTS.
FIRE ALARM PANELS - MOUNTING INDICATED FOR EACH TYPE.
FACP - FIRE ALARM CONTROL PANEL (TYPE AS INDICATED ON PLANS).
FAAP - FIRE ALARM REMOTE ANNUNCIATOR PANEL - FLUSH MOUNTED AT 5'-0" AFF TO TOP OF DEVICE.
FARA - FIRE ALARM REMOTE ANNUNCIATOR PANEL - FLUSH MOUNTED AT 5'-0" AFF TO TOP OF DEVICE.
FAPS - FIRE ALARM POWER SUPPLY EXTENDER PANEL - CONNECT TO 120V LIFE SAFETY CIRCUIT. SURFACE MOUNTED AT 5'-0" AFF TO TOP OF DEVICE. REFER TO FIRE ALARM SYSTEM RISER DIAGRAM FOR ADDITIONAL INFORMATION AND
WORK REQUIREMENTS.
FATC - FIRE ALARM TERMINAL CABINET
NACX - NOTIFICATION APPLIANCE CIRCUIT EXTENDER
MANUAL FIRE ALARM PULL STATION - MOUNT AT 48" AFF TO CENTERLINE OF DEVICE.
FIRE ALARM VISUAL SIGNAL DEVICE (ADA TYPE) MOUNTED 80" AFF UNLESS NOTED. RED HOUSING WITH WHITE "FIRE"
LETTERING.
FIRE ALARM AUDIBLE VISUAL (SPEAKER/STROBE) SIGNAL DEVICE (ADA TYPE) MOUNTED 80"AFF UNLESS NOTED. RED HOUSING
WITH WHITE "FIRE" LETTERING.
SMOKE DETECTOR - ADDRESSABLE INTELLIGENT PHOTOELECTRIC TYPE - CEILING MOUNTED.
EL - ELEVATOR RECALL
DUCT DETECTOR - ADDRESSABLE INTELLIGENT PHOTOELECTRIC DETECTOR, SAMPLING TUBES AND PROGRAMMABLE RELAY BASE. PROVIDE DUCT DETECTOR TEST/RESET SWITCH WITH REMOTE INDICATOR LAMP FOR EACH DUCT DETECTOR.
(TEST SWITCH MAY NOT BE SHOWN ON PLANS)
MAGNETIC TYPE DOOR HOLDER OUTLET. 24VDC.
PNEUMATICALLY ACTUATED COMBINATION SMOKE/FIRE DAMPER - FURNISHED AND INSTALLED BY THE MC. EC SHALL PROVIDE
(1) CONTROL MODULE AND (1) MONITOR MODULE.
CONTROL MODULE - ADDRESSABLE RELAY FOR CONTROL OF FIRE SMOKE DAMPERS. ELEVATOR RECALL, MAGNETIC DOOR
HOLDERS, AUTOMATIC DOORS, ETC.
MONITOR MODULE - ADDRESSABLE SUPERVISED FOR MONITORING TAMPER SWITCH , FLOW SWITCH, DAMPER POSITION,ETC.
TAMPER SWITCH - MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL TAMPER SWITCH. ELECTRICAL CONTRACTOR
SHALL PROVIDE MONITOR MODULE AND TEST SWITCH.
FLOW SWITCH - MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL FLOW SWITCH. ELECTRICAL CONTRACTOR SHALL
PROVIDE MONITOR MODULE AND TEST SWITCH.
D
F1.
F2.
F3.
F4.
F5.
F6.
DH
ABBREVIATIONS
GENERAL ELECTRICAL SPECIFICATION NOTES:
DEDICATED NEUTRAL CONDUCTORS
AC ABOVE COUNTER AT 9" UNLESS OTHERWISE NOTED
AF AMP FRAME
AFC ABOVE FINISHED CEILING
AFF ABOVE FINISHED FLOOR
AT AMP TRIP
BC BELOW COUNTER AT 18"AFF UNLESS OTHERWISE NOTED
BFC BELOW FINISHED CEILING
CM CEILING MOUNTED
EC ELECTRICAL CONTRACTOR
EG EQUIPMENT GROUND
GC GENERAL CONTRACTOR
GFCI GROUND FAULT CIRCUIT INTERRUPTER
IG ISOLATED GROUND
ITD INFORMATION TECHNOLOGY DEPARTMENT
PROVIDE DEFINITION: FURNISH, INSTALL AND CONNECT COMPLETE.
X EXISTING OUTLET, DEVICE, LIGHTING FIXTURE, CONDUIT, ETC. - TO REMAIN
XB INDICATES EXISTING OUTLET, LIGHTING FIXTURE, CONDUIT, ETC - TO BE REMOVED.
PROVIDE BLANK COVER FOR OUTLET AND MAINTAIN CIRCUIT CONTINUITY.
XL NEW LOCATION OF EXISTING OUTLET, DEVICE, LIGHTING FIXTURE, ETC.
XN EXISTING OUTLET, DEVICE, LIGHTING FIXTURE, ETC. - TO BE REPLACED WITH NEW OF
SPECIFIED TYPE
XR EXISTING OUTLET, DEVICE, LIGHTING FIXTURE, CONDUIT, ETC. - TO BE REMOVED COMPLETE-
MAINTAIN CIRCUIT CONTINUITY TO ADJACENT OUTLETS, EXTEND CONDUIT AND WIRING AS
REQUIRED.
XRR EXISTING OUTLET, DEVICE, LIGHTING FIXTURE, ETC. - TO BE REMOVED AND REINSTALLED
AT NEW LOCATION - EXTEND CONDUIT AND WIRING AS REQUIRED
MC MECHANICAL CONTRACTOR
MLO MAIN LUGS ONLY
NEC NATIONAL ELECTRICAL CODE
NF NOT FUSED
OFE OWNER FURNISHED EQUIPMENT
TC TELECOMMUNICATIONS CONTRACTOR
TCC TEMPERATURE CONTROLS CONTRACTOR
TV TELEVISION
VDC VOICE/DATA CONTRACTOR
VFD VARIABLE FREQUENCY DRIVE
WM WIREMOLD
WP WEATHERPROOF ENCLOSURE - NEMA 4
DEDICATED NEUTRAL CONDUCTORS ARE REQUIRED FOR ALL 120V AND 277V BRANCH CIRCUITS. MULTIWIRE BRANCH
CIRCUITS WITH SHARED NEUTRAL CONDUCTORS ARE NOT PERMITTED.
ROUTE NO MORE THAN (3) BRANCH CIRCUIT HOMERUNS PER EACH CONDUIT RUN.
THE FOLLOWING ITEMS SUPERCEDE ITEMS WITHIN THE SPECIFICATIONS:
ALL FIRESTOPPING MATERIAL SHALL BE MANUFACTURED BY STI. ALL INSTALLERS SHALL BE CERTIFIED INSTALLERS OF STI
FIRESTOPPING PRODUCTS AND HAVE PROOF OF CERTIFICATION.
THE FOLLOWING SYSTEM CABLING IS PERMITTED TO BE INSTALLED IN THE CABLE TRAY SYSTEM:
A. TEL/DATA CABLING
B. HOSPITAL PAGING SYSTEM
ALL OTHER SPECIAL SYSTEMS CABLING (FIRE ALARM) SHALL BE INSTALLED IN A COMPLETE CONDUIT
SYSTEM. E.C SHALL GROUND CABLE TRAY IN ACCORDANCE WITH N.E.C. ARTICLE 250.96.
GENERAL ELECTRICAL INSTALLATION NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
ALL MOUNTING HEIGHTS ARE TO CENTER OF DEVICE UNLESS OTHERWISE NOTED.
ALL NEW WALL MOUNTED ELECTRICAL DEVICES ARE TO BE INSTALLED FLUSH IN WALL UNLESS OTHERWISE NOTED.
ALL ELECTRICAL CONDUIT SHALL BE CONCEALED BEHIND FINISHED WALLS AND ABOVE FINISHED CEILING UNLESS OTHERWISE NOTED. THE COST TO CUT AND PATCH WALLS SHALL BE THE RESPONSIBILITY OF THE TRADE REQUIRING
THE CUTTING.
CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF CEILINGS REQUIRED FOR ELECTRICAL WORK.
CONTRACTOR SHALL REPLACE ANY DAMAGED CEILING TILES.
PRIOR TO INSTALLATION, VERIFY PRECISE LOCATION OF NEW OR RELOCATED WALL OR CEILING MOUNTED DEVICES
WITH ARCHITECTURAL ELEVATIONS AND REFLECTED CEILING PLANS.
COORDINATE ALL SHUT-DOWNS OF EXISTING ELECTRICAL SYSTEMS WITH OWNER A MINIMUM OF FOURTEEN (14) WORKING DAYS IN ADVANCE. ALL SHUT-DOWNS SHALL OCCUR DURING WEEKENDS OR BETWEEN 8:00PM AND 7:00AM
ON WEEKDAYS ("OFF-HOURS"). INCLUDE ALL PREMIUM TIME CHARGES IN BID.
ALL NOISE GENERATING OPERATIONS, INCLUDING CUTTING OF CEILINGS, WALLS AND FLOORS, CORING, DRILLING, ETC. SHALL BE SCHEDULED DURING WEEKENDS OR BETWEEN 8:00PM AND 7:00AM ON WEEKDAYS ("OFF-HOURS").
INCLUDING ALL PREMIUM TIME CHARGES IN BID.
CONTRACTOR SHALL CONNECT ALL MECHANICAL EQUIPMENT COMPLETE PER MANUFACTURER'S WIRING DIAGRAMS AND INSTRUCTIONS. COORDINATE WITH MECHANICAL CONTRACTOR AND VERIFY LOCATION, VOLTAGE, AMPS, NO. OF WIRES, AND PROTECTION REQUIREMENTS PRIOR TO ROUGH-IN. CONTACT ENGINEER WITH ANY DISCREPANCIES
FROM DESIGN DRAWINGS.
PROVIDE LIQUID-TIGHT FLEXIBLE METAL CONDUIT FOR FINAL CONNECTION TO MECHANICAL EQUIPMENT OR OTHER
EQUIPMENT WHICH MAY PROPAGATE VIBRATION.
ALL FLUORESCENT LAMPS THAT WILL NOT BE REUSED SHALL BE DISPOSED OF IN ACCORDANCE WITH EPA STANDARDS, AND WRITTEN EVIDENCE OF PROPER DISPOSAL SHALL BE FURNISHED TO THE OWNER.
ALL WORK SHALL BE PERFORMED IN STRICT CONFORMANCE WITH THE PHASING REQUIREMENTS OF THE PROJECT.
ALL COSTS ASSOCIATED WITH THESE REQUIREMENTS SHALL BE INCLUDED IN THE BID SUBMITTAL.
CONTRACTOR IS RESPONSIBLE FOR PROVIDING TEMPORARY LIGHTING TO ADEQUATELY LIGHT ALL CONSTRUCTION AREAS, TEMPORARILY PARTITIONED AREAS, AND EXIT CORRIDORS MAINTAINED DURING CONSTRUCTION.
DEFINITION: "PROVIDE" - FURNISH, INSTALL AND CONNECT COMPLETE.
PROJECT AND PHASING SCOPE LINES INDICATE WHERE GENERAL CONSTRUCTION BOUNDARIES OCCUR. ELECTRICAL
WORK AND UTILITY TIE-INS MAY OCCUR OUTSIDE OF SCOPE LINES.
C. NURSE CALL CABLING
D. CATV
COR CONTRACTING OFFICER'S REPRESENTATIVE
GENERAL LEGEND:
CODED NOTE - "1" INDICATES NOTE NUMBER
REVISION REFERENCE NUMBER
MECHANICAL EQUIPMENT IDENTIFIER
DETAIL REFERENCE - "1" INDICATES DETAIL NUMBER, "E0.1" INDICATES DRAWING NUMBER
COLUMN REFERENCE GRID
INDICATES EXISTING CONSTRUCTION WALL TYPE
INDICATES DEMOLITION WALL TYPE
INDICATES NEW CONSTRUCTION WALL TYPE
AC
GB1
E0.1
A
S
59459
M.P. LONG
R
E
S
O F
I
R
G E
NO
I
S
P
E
N
E
D
ERT
L EA
E I N
G
R
T
S
TE
A
H
F OO
IO
FREDRICK, FREDRICK & HELLER
ENGINEERS, INC.
672 EAST ROYALTON ROAD
BROADVIEW HTS., OHIO 44147
TEL. (440) 546-9696
FAX: (440) 546-9699
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1DESIGN AND CONSTRUCTION DOCUMENTS AS
INSTRUMENTS OF SERVICE ARE GIVEN IN
CONFIDENCE AND REMAIN THE PROPERTY OF
PERSPECTUS ARCHITECTURE. THE USE OF THIS
DESIGN AND THESE CONSTRUCTION
DOCUMENTS FOR PURPOSES OTHER THAN THE
SPECIFIC PROJECT NAMED HEREIN IS STRICTLY
PROHIBITED WITHOUT THE EXPRESSED
WRITTEN CONSENT OF PERSPECTUS
ARCHITECTURE. COPYRIGHT C 2019.
13212 Shaker Square Suite 204 Cleveland, Ohio 44120 P. 216.752.1800 F. 216.752.3833
18067
Z M y D o c u m e n ts \1
F F
H C
F R jd u a le .r v t
/2
/2
:4
:2
P
M
0-ES1-1
10701 East Blvd. Cleveland, OH 44106
06/26/2020 MPL JRD
541-19-101Renovate Operating RoomsBID ISSUEELECTRONIC SAFETY AND SECURITY LEGEND
& NOTES
Revisions: Date:
Bid Issue 06/26/2020
EXISTING
(18) PAIR BUNDLE OF
MULTI-MODE FIBER AND (6)
PAIR BUNDLE SINGLE-
MODE FIBER NETWORK
DATA RACK TO LENEL
SYSTEM RACK.
BATTERY
P/S
CR
CARD READER
HINGED DOOR TUB
INPUTS RELAY
RELAY (24VDC)
NIC
LINK
ADDITIONAL LENEL SYSTEM ENCLOSURE
(PROVIDE QUANTITY AS REQUIRED)
24VDC POWER SUPPLY
BATTERY
POWER
SUPPLY
BOARD
DC
OUTPUT
ADDITIONAL POWER SUPPLY
(PROVIDE QUANTITY AS REQUIRED)
ACCESS CONTROL SYSTEM RISER CODED NOTES:
EXISTING
EUL
BUILDING
DATA CENTER
EQUIPMENT
SHIELDED TWISTED PAIRS
(3 PAIRS, #22AWG) CAT6A TO
LENEL SYSTEM
SWITCH
20A-120V-1Ø
CRITICAL BRANCH
CIRCUIT
EXISTING
VAMC 3RD
FLOOR
TELEPHONE
EQUIPMENT ROOM
1" CONDUIT
(AS REQUIRED)
TO NEXT
1320 BOARD
NON METALLIC
RACEWAY
EXISTING SERVER
EXISTING
STORAGE ARRAY
EXISTING SERVER
EXISTING 4507
CORE SWITCH
EXISTING
STORAGE ARRAY
EXISTING SERVER
EXISTING
STORAGE ARRAY
APPROXIMATELY 40
CAMERA CAN
CONNECT TO EACH
SERVER
EXISTING 4507
CORE SWITCH
X
X
X
EXISTING (10) PAIRS OF
SINGLEMODE FIBER
DEDICATED TO LENEL
SYSTEM
EX. 72-STRAND FIBER
TERMINATION BOX
POWER AND
DATA LINK
TO PROJECT
AREA DEVICES
(CONDUIT AS
NECESSARY)
LENEL SYSTEM ENCLOSURE
PROVIDE COMPONENTS AS NECESSARY IN A LENEL SYSTEM CABINET TO PROVIDE CONNECTION FOR LOCAL DEVICES IN THE AREAS OUTLINED ON THE COMMUNICATION PLANS.
A. 18"W x 24"H BOX AND HINGED COVER [MAXIMUM (6) 2020 OR 1320 BOARDS PER BOX]
B. 12VDC POWER SUPPLY
C. 7.0 Ah BATTERIES
D. PROVIDE 2-WIRE RS-485 DATA LINK BETWEEN 2020 AND 1320 PANELS.
E. PROVIDE 2-WIRE POWER LINK BETWEEN 2020 AND 1320 PANELS.
F. 2020 MAIN BOARD [(1) 2020 MAIN BOARD IS REQUIRED FOR EVERY (30) 1320 SUB-BOARDS]
1. NIC LINK TO LENEL NETWORK
2. (2) CARD ACCESS READER INPUTS
3. (8) INPUTS
4. (2) DOOR RELEASE RELAYS
5. (4) RELAYS
E. 1320 SUB-BOARD
1. (2) CARD ACCESS READER INPUTS
2. (8) INPUTS
3. (2) DOOR RELEASE RELAYS
4. (4) RELAYS
DOOR HARDWARE POWER SUPPLY
PROVIDE 24VDC POWER SUPPLY IN A SYSTEM CABINET AS NECESSARY TO PROVIDE POWER TO LOCAL DEVICES IN THE AREAS OUTLINED ON THE COMMUNICATION PLANS.
A. 12"W x 16"H BOX AND HINGED COVER
B. (8) FUSED OUTPUTS
C. 6A TOTAL OUTPUT CURRENT
D. 40 Ah BATTERY
LENEL SYSTEM SWITCH
CONTRACTOR SHALL PROVIDE ALL ADDITIONAL COMPONENTS, SOFTWARE, ETC NECESSARY TO EXTEND THE EXISTING LENEL SECURITY SYSTEM AND SATISFY THE GENERAL SCOPE OF THIS
PROJECT WHICH IS TO:
A. MAINTAIN EXISTING SECURITY DEVICES OUTSIDE OF PROJECT AREA. REMOVE EXISTING DEVICES IN THE PROJECT AREA COMPLETE.
B. PROVIDE NEW SECURITY DEVICES IN THE PROJECT AREA AND CONNECT COMPLETE TO NEW LENEL 2020 OR 1320 PANELS.
C. PROVIDE QUANTITY OF PANELS AS REQUIRED TO SUPPORT THE NUMBER OF DEVICES SHOWN ON THE FLOOR PLANS.
D. PROVIDE GROUP OF (64) CARD READER LICENSES FOR THIS PROJECT.
ADDITIONAL CONDUITS ARE NOT SHOWN FOR CLARITY PURPOSES. CONTRACTOR SHALL ROUTE ALL POWER, SECURITY AND DATA WIRING IN APPROPRIATE CONDUITS.
GENERAL SECURITY SYSTEM NOTES:
S1. ALL SECURITY SYSTEM DEVICES SHALL BE CONNECTED COMPLETE TO THE LENEL SYSTEM IN ACCORDANCE
WITH ENGINEER APPROVED MANUFACTURER'S SHOP DRAWING WIRING DIAGRAMS AND DETAILS.
S2. ALL SECURITY SYSTEM CONDUCTORS SHALL BE INSTALL IN 3/4" MINIMUM SIZE CONDUIT STUBBED TO ABOVE FINISHED CEILING. ROUTE SECURITY SYSTEM CONDUCTORS IN J-HOOKS SPACE AT 5'-0" ON CENTER ABOVE
FINISHED CEILING.
S3. REFER TO SPECIFICATIONS SECTIONS IN DIVISION 28 FOR ADDITIONAL REQUIREMENTS.
EXISTING FIBER
PATCH PANELS
EXISTING LENEL
SYSTEM RACK
EXISTING TYPICAL NETWORK
DATA RACK (A1-A6 ON
PLANS)
EX. 72-STRAND FIBER
TERMINATION BOX
EXISTING PAIR 62.5
MULTIMODE
FIBER OPTIC CABLE
EXISTING LENEL
PANELS
WITH 2020 AND 1320
DEVICES. REFER TO
ENLARGED OIT PLANS
EXISTING GREEN
CAT6 CABLE
CAMERAS
(TYPICAL)
NEW GREEN
CAT6A CABLE
EXISTING
TELECOM ROOM 2-C363
EXISTING TELECOM ROOM
FIBER PATCH PANEL
X
X
X
EXISTING LENEL
SWITCH
EXISTING MULTI-MODE
FIBER BUNDLE BETWEEN
OIT ROOM AND MCR WITH (1)
PAIR PATCHED TO EXISTING
LENEL SYSTEM
X
X
X
SECURITY DEVICE NAMING
CONTRACTOR SHALL PROGRAM DEVICES PER VA NAMING STANDARD:
CAMERA: C(1B-100): C = CAMERA, 1 = FLOOR, B= BUILDING SECTION, 100 = ROOM NUMBER
DOOR: D(BB-100): D = DOOR, FIRST B = FLOOR, SECOND B = BUILDING SECTION, 100 = ROOM NUMBER PANIC BUTTONS: P(1C-100) P = PANIC BUTTON, 1 = FLOOR, C = BUILDING SECTION, 100 = ROOM NUMBER
S
59459
M.P. LONG
R
E
S
O F
I
R
G E
NO
I
S
P
E
N
E
D
ERT
L EA
E I N
G
R
T
S
TE
A
H
F OO
IO
FREDRICK, FREDRICK & HELLER
ENGINEERS, INC.
672 EAST ROYALTON ROAD
BROADVIEW HTS., OHIO 44147
TEL. (440) 546-9696
FAX: (440) 546-9699
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1DESIGN AND CONSTRUCTION DOCUMENTS AS
INSTRUMENTS OF SERVICE ARE GIVEN IN
CONFIDENCE AND REMAIN THE PROPERTY OF
PERSPECTUS ARCHITECTURE. THE USE OF THIS
DESIGN AND THESE CONSTRUCTION
DOCUMENTS FOR PURPOSES OTHER THAN THE
SPECIFIC PROJECT NAMED HEREIN IS STRICTLY
PROHIBITED WITHOUT THE EXPRESSED
WRITTEN CONSENT OF PERSPECTUS
ARCHITECTURE. COPYRIGHT C 2019.
13212 Shaker Square Suite 204 Cleveland, Ohio 44120 P. 216.752.1800 F. 216.752.3833
18067
Z M y D o c u m e n ts \1
F F
H C
F R jd u a le .r v t
/2
/2
:5
:0
P
M
0-ES1-2
10701 East Blvd. Cleveland, OH 44106
06/26/2020 MPL JRD
541-19-101Renovate Operating RoomsBID ISSUEACCESS CONTROL SYSTEM RISER, DIAGRAM, AND NOTES
NOT TO SCALE
ACCESS CONTROL SYSTEM RISER AND DETAILS1
ELECTRIFIED LOCKSET - MOUNTED ON SECURED SIDE OF
THE DOOR. 24VDC. CONTAINS REQUEST-TO-EXIT AND DOOR
POSITION CONTACTS. LOCKSET PROVIDED BY DOOR
HARDWARE VENDOR AND CONNECTED COMPLETE BY
SECURITY CONTRACTOR.
CARD READER - HID RP40H OR EQUAL. MOUNTS IN
2-GANG BOX W/SINGLE GANG RING ON NON-SECURED SIDE OF THE DOOR.
OPERATES ELECTRIC LOCKSET.
48"
6"SQ. x 4"D JUNCTION BOX
WITH SCREW COVER
ABOVE FINISHED CEILING.
COIL AND TAG CABLES
INSIDE BOX FOR FUTURE
EXTENSION.
#22/6 CABLE THROUGH DOOR
WIREWAY- TERMINATE TO LOCKSET
12/24VDC ACCESS CONTROL WIRING TO LENEL SECURITY PANEL.
SINGLE MULTI-CONDUCTOR CABLE ASSEMBLY. ROUTE IN 3/4"C TO
NEAREST CABLE TRAY. CONDUCTORS AS REQUIRED FOR CARD READER,
12/24VDC LOCKSET, REQUEST-TO-EXIT,AND DOOR POSITION CONTACT.
JUNCTION BOX IN DOOR FRAME WITH
HOLES TO RECEIVE CONDUIT. PLUG ANY
UNUSED HOLES. TERMINATE ELECTRIC
HINGE CABLES IN DOOR FRAME JUNCTION
BOX.
6" UON
(3) 22AWG SHIELDED TWISTED PAIRS
ELECTRIC HINGE - 12/24VDC, INCLUDES
REQUEST TO EXIT OUTPUT CONTACTS,
DOOR POSITION SWITCH AND 4'-0" CABLE.
FAIL SECURE OPERATING MODE.
FURNISHED AND CONNECTED BY
CONTRACTOR.
#18/6 CABLE
All items,except the card readers, are to be mounted on the secure side of the door unless otherwise noted.
JB
CEILING
FLOORFLOOR
CEILING
JB
6"SQ. x 4"D JUNCTION BOX
WITH SCREW COVER
ABOVE FINISHED CEILING.
COIL AND TAG CABLES
INSIDE BOX FOR FUTURE
EXTENSION.
R
RELAY
(OUT SWING) (OUT SWING)
ALL ITEMS, UNLESS OTHERWISE
NOTED, ARE TO BE MOUNTED ON
THE SECURE SIDE OF THE DOOR.
12/24VDC ACCESS CONTROL WIRING TO ACCESS CONTROL PANEL.
SINGLE MULTI-CONDUCTOR CABLE ASSEMBLY. ROUTE IN 3/4"C TO NEAREST CABLE TRAY.
CONDUCTORS AS REQUIRED FOR CARD READER, 12/24VDC LOCKSET, REQUEST-TO-EXIT,
AND DOOR POSITION CONTACT.
ELECTRIC POWER TRANSFER HINGE -
INCLUDES DOOR POSITION SWITCH AND 4'-0"
CABLE. FAIL SECURE OPERATING MODE.
FURNISHED AND CONNECTED BY
CONTRACTOR.
JUNCTION BOX IN DOOR FRAME WITH
HOLES TO RECEIVE CONDUIT. PLUG
ANY UNUSED HOLES. TERMINATE
ELECTRIC HINGE CABLES IN DOOR
FRAME JUNCTION BOX.
(INACTIVE LEAF)
#18/6 CABLE THROUGH
DOOR WIREWAY -
TERMINATE TO
LOCKSET
ELECTRIFIED LOCKSET - 24VDC. CONTAINS
REQUEST-TO-EXIT AND DOOR POSITION
CONTACTS. LOCKSET PROVIDED BY DOOR
HARDWARE VENDOR AND CONNECTED
COMPLETE BY SECURITY CONTRACTOR.
PP
48"
CARD READER - HID RP40H OR EQUAL.
MOUNTS IN 2-GANG BOX W/SINGLE GANG
RING ON NON-SECURED SIDE OF THE
DOOR.
OPERATES ELECTRIC LOCKSET.
AUTODOOR
3#22 STP
120V FOR AUTODOOR OPERATOR - 2#12 AND 1#12EG
AUTODOOR
POWER
SUPPLY
CR
(2) #22 SHIELDED
TWISTED PAIRS
(PER PUSH PLATE
REQUEST-TO-EXIT
MOTION DETECTOR
2#18 SHIELDED
TWISTED PAIR
3#22 SHIELDED
TWISTED PAIR
CR
FLOOR
CEILING
JB
6"SQ. x 4"D JUNCTION BOX WITH SCREW COVER
ABOVE FINISHED CEILING. COIL AND TAG CABLES
INSIDE BOX FOR FUTURE EXTENSION.
R
RELAY
48"
(OUT SWING) (IN SWING)
CARD READER - HID RP40H OR
EQUAL. MOUNTS IN
2-GANG BOX W/SINGLE GANG
RING ON NON-SECURED SIDE OF
THE DOOR. OPERATES MAGNETIC
LOCKS.
ALL ITEMS, UNLESS OTHERWISE
NOTED, ARE TO BE MOUNTED ON
THE SECURE SIDE OF THE DOOR.
ELECTRIC POWER TRANSFER HINGE - INCLUDES
DOOR POSITION SWITCH AND 4'-0" CABLE. FAIL
SECURE OPERATING MODE. FURNISHED AND
CONNECTED BY CONTRACTOR.
JUNCTION BOX IN DOOR FRAME WITH HOLES
TO RECEIVE CONDUIT. PLUG ANY UNUSED
HOLES. TERMINATE ELECTRIC HINGE CABLES
IN DOOR FRAME JUNCTION BOX.
(3) #22 SHIELDED
TWISTED PAIRS
MOTION DETECTOR
2#18 SHIELDED
TWISTED PAIR
MAGNETIC LOCKS
AUTODOOR
3#22 STP
120V FOR AUTODOOR OPERATOR - 2#12 AND 1#12EG
AUTODOOR
POWER
SUPPLY
12/24VDC ACCESS CONTROL WIRING TO REMOTE DOOR RELEASE PANEL.
ROUTE IN 3/4"C TO NEAREST CABLE TRAY.
(2) #22 AND (4) #18 SHIELDED TWISTED PAIRS
PP
(2) #22 SHIELDED TWISTED
PAIRS(PER PUSH PLATE)
12/24VDC ACCESS CONTROL WIRING TO ACCESS CONTROL PANEL.
SINGLE MULTI-CONDUCTOR CABLE ASSEMBLY. ROUTE IN 3/4"C TO NEAREST CABLE TRAY.
CONDUCTORS AS REQUIRED FOR CARD READER, 12/24VDC LOCKSET, REQUEST-TO-EXIT,
AND DOOR POSITION CONTACT.
CEILING
FLOOR
KEYPAD PROXIMITY READER - HID #RP40 OR
EQUAL. MOUNTS IN 2-GANG BOX W/SINGLE
GANG RING. OPERATES ELECTRIC STRIKE
48"
6"SQ. x 4"D JUNCTION BOX
WITH SCREW COVER
ABOVE FINISHED CEILING.
COIL AND TAG CABLES
INSIDE BOX FOR FUTURE
EXTENSION.
12/24VDC ACCESS CONTROL WIRING TO LENEL SECURITY PANEL.
VIA SINGLE MULTI-CONDUCTOR CABLE ASSEMBLY
(3) #22 SHIELDED TWISTED PAIRS FOR CARD READER
(2) #18 SHIELDED TWISTED PAIRS FOR 12/24VDC LOCKSET
(2) #18 SHIELDED TWISTED PAIRS FOR REQUEST-TO-EXIT
(2) #18 SHIELDED TWISTED PAIRS FOR DOOR POSITION CONTACTS
(2) #18 SHIELDED TWISTED PAIRS FOR SPARE
6" UON
(3) 22AWG SHIELDED TWISTED PAIRS
All items,except the card readers, are to be mounted on the secure side of the door.
JB
CEILING
FLOOR
REQUEST-TO-EXIT
MOTION SENSOR
ELECTRIC STRIKE - 24VDC. MOUNTED IN INACTIVE DOOR
LEAF. PROVIDE BY DOOR HARDWARE VENDOR AND
CONNECTED COMPLETE BY SECURITY CONTRACTOR.
PROVIDE JUNCTION BOX IN DOOR FRAME WITH HOLES TO
RECEIVE CONDUIT. PLUG ANY UNUSED HOLES. TERMINATE
ELECTRIC HINGE CABLES IN DOOR FRAME JUNCTION BOX.
DOOR
CONTACTS
S
59459
M.P. LONG
R
E
S
O F
I
R
G E
NO
I
S
P
E
N
E
D
ERT
L EA
E I N
G
R
T
S
TE
A
H
F OO
IO
FREDRICK, FREDRICK & HELLER
ENGINEERS, INC.
672 EAST ROYALTON ROAD
BROADVIEW HTS., OHIO 44147
TEL. (440) 546-9696
FAX: (440) 546-9699
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1DESIGN AND CONSTRUCTION DOCUMENTS AS
INSTRUMENTS OF SERVICE ARE GIVEN IN
CONFIDENCE AND REMAIN THE PROPERTY OF
PERSPECTUS ARCHITECTURE. THE USE OF THIS
DESIGN AND THESE CONSTRUCTION
DOCUMENTS FOR PURPOSES OTHER THAN THE
SPECIFIC PROJECT NAMED HEREIN IS STRICTLY
PROHIBITED WITHOUT THE EXPRESSED
WRITTEN CONSENT OF PERSPECTUS
ARCHITECTURE. COPYRIGHT C 2019.
13212 Shaker Square Suite 204 Cleveland, Ohio 44120 P. 216.752.1800 F. 216.752.3833
18067
Z M y D o c u m e n ts \1
F F
H C
F R jd u a le .r v t
/2
/2
:5
:1
P
M
0-ES1-3
10701 East Blvd. Cleveland, OH 44106
06/26/2020 MPL JRD
541-19-101Renovate Operating RoomsBID ISSUEACCESS CONTROLLED DOOR DETAILS AND
NOTES
NOT TO SCALE
ACCESS CONTROLLED DOOR TYPE 1 1NOT TO SCALE
ACCESS CONTROLLED DOOR TYPE 2 2
NOT TO SCALE
ACCESS CONTROLLED DOOR TYPE 3 3
ACCESS CONTROL DOOR GENERAL NOTES
1 VERIFY ACCESS CONTROLLED DOOR REQUIREMENTS AND EXACT CABLING REQUIREMENTS WITH SECURITY SYSTEM AND DOOR HARDWARE VENDOR PRIOR TO ROUGH-IN. CABLING INDICATED IS FOR REFERENCE ONLY. CONTRACTOR SHALL PROVIDE SINGLE, PLENUM-RATED COMPOSITE CABLE DESIGNED FOR ACCESS CONTROL SYSTEMS FROM ACCESS CONTROL PANEL TO DOOR LOCATION AND ROUTE CABLING TO INDIVIDUAL DEVICES AS REQUIRED. DO NOT PROVIDE SEPARATE ACCESS CONTROL CABLING FOR EACH DEVICE FROM CONTROL PANEL TO DOOR LOCATIONS.
2 CONTRACTOR IS RESPONSIBLE FOR ALL ROUGH-INS, DEVICES, AND CABLING NECESSARY FOR A COMPLETE
INSTALLATION. COORDINATE REQUIREMENTS FOR ALL DOORS WITH DOOR HARDWARE VENDOR.
3 CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS AND DOOR HARDWARE SCHEDULE FOR EXACT QUANTITY AND LOCATION OF ACCESS CONTROL DEVICES. CONTACT ENGINEER SHOULD A DISCREPANCY ARISE BETWEEN
ACCESS CONTROL DETAILS AND ARCHITECTURAL DRAWINGS.
4 ACCESS CONTROLLED DOORS MAY OCCUR IN CURTAIN WALL SYSTEMS. PROVIDE POST MOUNTED PUSH BUTTONS/CARD READERS WHERE NECESSARY. COORDINATE EXACT REQUIREMENTS WITH DOOR HARDWARE
VENDOR.
5 ALL ACCESS CONTROL CABLING SHALL BE INSTALLED IN 3/4" MINIMUM CONDUIT. WHERE 3/4" CONDUIT IS NOT FEASIBLE, CONTRACTOR SHALL RECEIVE WRITTEN APPROVAL FROM FACILITY PROJECT MANAGER TO PROVIDE 1/2"C OR SMALLER. ACCESS CONTROL CABLING SHALL BE ROUTED IN CONDUIT TO NEAREST CABLE TRAY AND IS
PERMITTED TO BE RUN IN CABLE TRAY BACK TO ACCESS CONTROL PANEL.
6 PROVIDE FACILITY STANDARD LABELING ON ALL ACCESS CONTROL CABLING (ROOM NAME, DEVICE AND DOOR NUMBER). LABEL RELAYS ON ACCESS CONTROL SYSTEM BOARDS WITH DEVICE BEING SERVED AND ROOM NUMBER.
7 PROJECT MANAGER SHALL WITNESS COMPLETE FUNCTIONALITY TESTING OF ACCESS CONTROL, VIDEO SURVEILLANCE, AND PANIC ALARM SYSTEMS PRIOR TO FINAL ACCEPTANCE. TESTING SHALL INCLUDE REPRESENTATIVE FROM FACILITY SECURITY. COORDINATE SCHEDULE OF TESTING WITH PROJECT MANAGER.
8 REFER TO ARCHITECTURAL PLANS FOR QUANTITY AND LOCATION OF AUTODOOR PUSH PLATES.
NOT TO SCALE
ACCESS CONTROLLED DOOR TYPE 4 4
F FF
F
F
TS WF
F
F
F
F
F
F
F
F
F
TS
WF
P
P
F
F
F
F
F
F
F
F
P
F
C R
CR
F
PA
F
F
F
D1
D1
16C 17B 18E 20A 24C 25B 26B 28B25C
C2
A1
ZZ
YY
XX
UU
RR
ss
B
D
VV
27o 32
E
G1
C1
17a 24b 25a 26a 28 3119c 23b
XRR
TYP
X
X
X
X
X
X
X
X
X
X
X
X
X
PHASE 2 SCOPE OF WORK
TYP
TYP
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
XX
X
X
XRR
X
X
X X
X
X
Patient Room #3 (Isolation)
2D127B
Anteroom
2D127A
EMS
Closet
2D110
Gas Room Non
Oxidizing
2514A
Laser Scales Video
Equipment
Toilet
2D127C
Patient Room #5
2D112
Patient Room #4
2D111
Patient Room #2
2D126
Lounge / Dictation
2D251
CRNA
2D253
Corridor
2D250
Women Lockers
2D257A
Surgery Waiting
2D270
Work
2D260D
Work
2D260E
Work
2D260F
Holding
2D260
Holding
Corridor
2500B
Implant Storage
Anesthesia Work Room
Corridor
2500H
OR-7
General
OR-6
General
Electric
EMS
Anesthesia Storage
EMS
2508A
Sub Sterile
Sub Sterile
Dictation
Sterile Storage
General
OR-5
General
OR-4
Storage
OR-3
Orthopedic
Elec.
2517A
Sub Sterile
Sub Sterile
Storage
OR-1
Cardiac
Pump Room
Gas Room Oxidizing
TEMP.
Implant Storage
Rm.
Stair
2S7
Office
Special Equipment Records
OR-2
Neuro
Bed/ Treatment
Room
Medication Prep
Room
Workroom
Corridor
2C100E
Corridor
2500A
Pharmacy
Unisex RR
Corridor
2500J
Corridor
2C280
Foyer
2D255E
Alcove
2D251A
Soiled Utility
2D254
Sterile Supply
2D254A
Locker Room
2D252
Dictation
2D252A
Office
Corridor
2C280
Light Room
2500I
TEMP.
Medical
Prep Rm.
Soiled Elevator
Clean Elevator
Scrub
2500N Scrub
2500O
Upper Mechanical
Room
2500Q
Procedure
2C231 Procedure
2C232
Staff Women
2B213
Staff Men
2B212
Procedure
2C233
Sub-Sterile
2C235
Passage
2C230
PACU EMS
2C234 Stair #9
2C202
PACU
Cubicle 5
2C237E
PACU
Cubicle 6
2C237F
PACU
Cubicle 4
2C237D
PACU
Cubicle 3
2C237C
PACU
Cubicle 2
2C237B
PACU
Cubicle 1
2C237A
Electrical Rm.
2519A
OI&T
Office
2D261B
Office
2D261A
Office
2D261C
Control
2D261
Nurse Mgr.
2D262
S
59459
M.P. LONG
R
E
S
O F
I
R
G E
NO
I
S
P
E
N
E
D
ERT
L EA
E I N
G
R
T
S
TE
A
H
F OO
IO
FREDRICK, FREDRICK & HELLER
ENGINEERS, INC.
672 EAST ROYALTON ROAD
BROADVIEW HTS., OHIO 44147
TEL. (440) 546-9696
FAX: (440) 546-9699
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1DESIGN AND CONSTRUCTION DOCUMENTS AS
INSTRUMENTS OF SERVICE ARE GIVEN IN
CONFIDENCE AND REMAIN THE PROPERTY OF
PERSPECTUS ARCHITECTURE. THE USE OF THIS
DESIGN AND THESE CONSTRUCTION
DOCUMENTS FOR PURPOSES OTHER THAN THE
SPECIFIC PROJECT NAMED HEREIN IS STRICTLY
PROHIBITED WITHOUT THE EXPRESSED
WRITTEN CONSENT OF PERSPECTUS
ARCHITECTURE. COPYRIGHT C 2019.
13212 Shaker Square Suite 204 Cleveland, Ohio 44120 P. 216.752.1800 F. 216.752.3833
18067
Z M y D o c u m e n ts \1
F F
H C
F R jd u a le .r v t
/2
/2
:4
:3
P
M
2-ES2-1
10701 East Blvd. Cleveland, OH 44106
06/26/2020 MPL JRD
541-19-101Renovate Operating RoomsBID ISSUEPARTIAL SECOND FLOOR F.A. & SECURITY
DEMO PLAN - PHASE 2
N
ELECTRICAL DEMOLITION NOTES
D1 ALL EXISTING LIGHTING FIXTURES, RECEPTACLES, SPECIAL SYSTEMS OUTLETS, CONDUIT, WIRING ETC. THAT WILL NOT BE REUSED IN THE REMODELED INSTALLATION SHALL BE REMOVED UNLESS OTHERWISE NOTED. THIS DEMOLITION SHALL INCLUDE ALL ELECTRICAL ITEMS SHOWN ON THIS PLAN THAT ARE NOT DESIGNATED BY "X", "XN" OR "XRR" AND ALL OTHER ADDITIONAL ITEMS THAT ARE NOT SHOWN BUT THAT MUST BE REMOVED IN ORDER TO
PRODUCE A NEAT, FINISHED, PROPERLY FUNCTIONING ELECTRICAL INSTALLATION. MAINTAIN CIRCUIT CONTINUITY TO ALL EXISTING REUSED ELECTRICAL SYSTEMS COMPONENTS - PROVIDE ALL CONDUIT AND WIRING NECESSARY TO ACHIEVE THE SAME. THE CONTRACTOR SHALL FIELD VERIFY THE NATURE AND EXTENT OF ALL DEMOLITION
WORK AND SHALL INCLUDE COST FOR THE SAME IN THE BID SUBMITTAL.
D2 ALL EXISTING REMOVED ELECTRICAL EQUIPMENT, DEVICES, ETC. THAT ARE NOT RETAINED BY THE OWNER SHALL
BE DISPOSED OF BY THE ELECTRICAL CONTRACTOR.
D3 DASHED WALLS ON PLAN INDICATE EXISTING CONSTRUCTION TO BE REMOVED.
D4 REFER TO ELECTRICAL LEGEND FOR ALL SYMBOL DESIGNATIONS. NOTE SPECIAL ATTENTION TO SELECTED EXISTING DEVICES, WIREWAYS, ETC. MARKED XB, XRR OR XN, AND REMOVE/BLANK OFF, RELOCATE OR REPLACE
THESE COMPONENTS AS REQUIRED.
D5 MAINTAIN CIRCUIT CONTINUITY TO ALL EXISTING ELECTRICAL SYSTEM COMPONENTS IN AREAS NOT BEING REMODELED UNLESS OTHERWISE NOTED. PROVIDE ALL CONDUIT AND WIRING EXTENSIONS NECESSARY TO
ACHIEVE SAME.
D6 THE ELECTRICAL CONTRACTOR SHALL CLOSELY COORDINATE ALL ELECTRICAL DEMOLITION WORK WITH THE GENERAL AND MECHANICAL CONTRACTORS, AND SHALL DISCONNECT ALL REQUIRED CIRCUITS IN A TIMELY
MANNER.
D7 REFER TO ARCHITECTURAL PLANS FOR SPECIFIC PHASING REQUIREMENTS.
# CODED NOTES
1 REFER TO DRAWING 2-E5-1 "PARTIAL SECOND FLOOR SUBPHASES A,B - PHASE 2" FOR DETAILED
PHASING REQUIREMENTS.
REMOVE ALL FIRE ALARM, SECURITY DEVICES, JUNCTION BOXES, AND ETC. FROM PHASE 2 ARE
UNLESS OTHERWISE NOTED. REMOVE ALL ASSOCIATED CONDUIT AND WIRING COMPLETE TO
SOURCE. MAINTAIN OPEATION OF DEVICES OUTSIDE OF PHASE 2 AREA.
0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'
1/8" = 1'-0"
PARTIAL SECOND FLOOR FIRE ALARM AND
SECURITY DEMOLITION PLAN - PHASE 2 1
PHASING GENERAL NOTES:
ALL WORK IN PHASE 2 SHALL BE DONE DURING OFF-HOURS. REFER TO THE GENERAL REQUIREMENTS FOR
ADDITIONAL INFORMATION.
1.
A-front
B -rig h t
C-back
D -le ft
A-front
B -rig h t
C-back
D -le ft
A-front B -ri gh t
C-backD -le ft
A-front
B -rig h t
C-back
D -le ft
A-front
B -rig h t
C-back
D -le ft
A-front
B -rig h t
C-back
D -le ft
A-front
B -rig h t
C-back
D -le ft
A-front B -ri gh t
C-backD -le ft
A -f ro n t
B-right
C -b a ck
D-left
A -front
B-rig ht
C -b ack
D-left
F
F
F
F
TS
WF
F
F
F
F
F
F
F
F
P
P
F
F
F
F
F
F
F
P
F
D2
D1
CR
P
TS
TS
TS
D3
F
F
F
D1
D1
D1
D1
D1
D1
D1
D1
16C 17B 18E 20A 24C 25B 26B 28B25C
C2
A1
ZZ
YY
XX
UU
RR
ss
B
D
VV
E
G1
C1
17a 24b 25a 26a 28 3119c 23b
XL
XL
SCP
X
X
FACP
X
X X
X X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
PHASE 2 SCOPE OF WORK
Electrical Room-1
2C213-1
Scrub-1
2C200D-1
Ortho Equipment-1
2C215A-1
Ortho OR
(OR-08)-1
2C215-1
General
OR
(OR-09)-1
2C216-1
X
X
Semi-Restricted
2C200A
Semi-Restricted
2C200F
General
OR
(OR-07)
2C212
Bed Holding
2C200E
Bed Holding
2C200H
Scrub
2C200G
Scrub
2C200J
Bed Holding
2C200K
Scrub
2C200L
Bed Holding
2C200M
Anesthesia Workroom
2C218
Office
2D285
Office
2D284
Cart Holding
2C219
X
X
X
X
X
X
XX
X
X
X
X
X X
X X
2-T2-3
Soiled Holding
2D281
Anesthesia Office
2D282
Anesthesia Storage
2C222
Medication Prep
Room
2C219A
Alcove
2C220R
Alcove
2C200Q
Office
2C283
Control Room
2D-261
Laboratory, Frozen Section
2C214
X
X
TYP3
TYP
Patient Room #3 (Isolation)
2D127B
Anteroom
2D127A
EMS
Closet
2D110
Gas Room Non
Oxidizing
2514A
Laser Scales Video
Equipment
Toilet
2D127C
Toilet
2D263
Patient Room #4
2D111
Lounge / Dictation
2D251
Work
2D260D
Work
2D260E
Work
2D260F
Office
2D261C
Sub Sterile
General
OR-4
Storage
OR-3
Orthopedic
Elec.
2517A
Sub Sterile
Storage
OR-1
Cardiac
Pump Room
Gas Room Oxidizing
TEMP.
Implant Storage
Rm.
Stair
2S7
Office
Special Equipment Records
OR-2
Neuro
Corridor
2C100E
Foyer
2D255E
Dictation
2D252A
Office
Corridor
2C280
Light Room
2500I
TEMP.
Medical
Prep Rm.
Clean Elevator
Scrub
2500N
Scrub
2500O
Upper Mechanical
Room
2500Q
Procedure
2C233
Procedure
2C232 Procedure
2C231
Passage
2C230
Sub-Sterile
2C235
HAC
2C224
PACU EMS
2C234 Stair #9
2C202
PACU
Cubicle 1
2C237A
PACU
Cubicle 2
2C237B
PACU
Cubicle 3
2C237C
PACU
Cubicle 4
2C237D
PACU
Cubicle 5
2C237E
PACU
Cubicle 6
2C237F Nurse Mgr.
2D262
Surgery Waiting
2D270
CRNA
2D253
OI&T
Electrical Rm.
2519A
S
59459
M.P. LONG
R
E
S
O F
I
R
G E
NO
I
S
P
E
N
E
D
ERT
L EA
E I N
G
R
T
S
TE
A
H
F OO
IO
FREDRICK, FREDRICK & HELLER
ENGINEERS, INC.
672 EAST ROYALTON ROAD
BROADVIEW HTS., OHIO 44147
TEL. (440) 546-9696
FAX: (440) 546-9699
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1DESIGN AND CONSTRUCTION DOCUMENTS AS
INSTRUMENTS OF SERVICE ARE GIVEN IN
CONFIDENCE AND REMAIN THE PROPERTY OF
PERSPECTUS ARCHITECTURE. THE USE OF THIS
DESIGN AND THESE CONSTRUCTION
DOCUMENTS FOR PURPOSES OTHER THAN THE
SPECIFIC PROJECT NAMED HEREIN IS STRICTLY
PROHIBITED WITHOUT THE EXPRESSED
WRITTEN CONSENT OF PERSPECTUS
ARCHITECTURE. COPYRIGHT C 2019.
13212 Shaker Square Suite 204 Cleveland, Ohio 44120 P. 216.752.1800 F. 216.752.3833
18067
Z M y D o c u m e n ts \1
F F
H C
F R jd u a le .r v t
/2
/2
:4
:5
P
M
2-ES2-2
10701 East Blvd. Cleveland, OH 44106
06/26/2020 MPL JRD
541-19-101Renovate Operating RoomsBID ISSUEPARTIAL SECOND FLOOR F.A. & SECURITY
PLAN - PHASE 2
N
# CODED NOTES
1 WORK IN OUTLINED AREA (PHASES 2A AND 2B) SHALL BE DONE DURING OFF HOURS. REFER TO
ARCHITECTURAL DRAWINGS FOR EXACT PHASING REQUIREMENTS.
CONNECT ALL NEW FIRE ALARM DEVICES TO EXISTING FIRE ALARM TERMINAL CABINET IN
TELECOM ROOM 2-C363.
CONNECT ALL NEW SECURITY DEVICES AND SECURITY CAMERA TO EXISTING LENEL CONTROL
PANEL IN TELECOM ROOM 2-C363. REFER TO DRAWING 0-ES1-2 AND 0-ES1-3 FOR ADDITIONAL
INFORMATION.
FIRE ALARM GENERAL NOTES
F1 ALL FIRE ALARM SYSTEM DEVICES SHALL BE CONNECTED COMPLETE TO THE MAIN FIRE ALARM SYSTEM CONTROL
PANEL IN ACCORDANCE WITH ENGINEER APPROVED MANUFACTURER'S SHOP DRAWING WIRING DIAGRAMS AND
DETAILS.
F2 ALL FIRE ALARM SYSTEM CONDUCTORS SHALL BE INSTALLED IN 3/4" MINIMUM SIZE CONDUIT SYSTEM.
F3 IN GENERAL ALL MANUAL PULL STATIONS SHALL BE INSTALLED AT 48" ABOVE FINISHED FLOOR. MANUAL PULL STATIONS SHALL BE INSTALLED WITHIN 5'-0" OF ALL EXIT DOORWAY OPENINGS AT EACH EXIT ON EACH FLOOR.
ADDITIONAL MANUAL PULL STATIONS SHALL BE PROVIDED SO THAT THE TRAVEL DISTANCE TO THE NEAREST PULL
STATION WILL NOT EXCEED 200' MEASURED HORIZONTALLY ON THE SAME FLOOR.
F4 ALL AUDIO/VISUAL AND VISUAL ONLY FIRE ALARM SYSTEM DEVICES SHALL BE ADA TYPE. IN ALL CASES VISUAL DEVICES SHALL BE WALL MOUNTED AT 80" ABOVE FINISHED FLOOR. VISUAL DEVICES SHALL BE LOCATED NOT MORE THAN 15' FROM THE END OF ALL CORRIDORS WITH A SEPARATION NOT GREATER THAN 100' BETWEEN DEVICES. AUDIO DEVICES SHALL BE INSTALLED THROUGHOUT THE BUILDING TO ATTAIN MINIMUM DECIBEL LEVELS REQUIRED BY CODE. COMBINATION AUDIO/VISUAL DEVICES AND ADDITIONAL VISUAL ONLY DEVICES SHALL BE
INSTALLED AT LOCATIONS AS INDICATED ON FLOOR PLANS.
F5 IN GENERAL SMOKE DETECTORS SHALL BE INSTALLED ON CEILINGS WITH SPACING NOT TO EXCEED
MANUFACTURER'S RECOMMENDATION.
F6 SPRINKLER SYSTEM WATERFLOW ALARM INITIATING DEVICES SHALL BE CONNECTED COMPLETE TO THE FIRE
ALARM SYSTEM.
F7 DUCT TYPE SMOKE DETECTORS SHALL BE PROVIDED FOR ALL HVAC RETURN AIR SYSTEMS WITH DESIGN CAPACITY GREATER THAN 2,000 CFM. WHERE RETURN AIR RISERS SERVE TWO OR MORE STORIES, AND ARE PART OF A RETURN AIR SYSTEM HAVING A DESIGN CAPACITY GREATER THAN 15,000 CFM, DUCT DETECTORS SHALL BE PROVIDED AT EACH STORY. COORDINATE EXACT DETECTOR LOCATIONS AND PROVISION OF ADEQUATE DUCT
LENGTHS WITH THE MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN.
F8 PROVIDE ALL FIRE ALARM SYSTEM COMPONENTS NECESSARY FOR SHUT DOWN OF HVAC EQUIPMENT BY THE FIRE
ALARM SYSTEM WHERE SAME IS REQUIRED.
F9 PROVIDE ALL FIRE ALARM SYSTEM COMPONENTS NECESSARY FOR ELEVATOR CAPTURE BY THE FIRE ALARM
SYSTEM WHERE SAME IS REQUIRED.
F10 SMOKE DETECTORS SHALL BE INSTALLED WITHIN 5'-0" OF CENTERLINE OF SMOKE DOORS ON HOLD-OPEN.
F11 SMOKE DETECTORS SHALL NOT BE LOCATED CLOSER THAN 3'-0" FROM AN AIR SUPPLY DIFFUSER.
F12 AUTOMATIC DOORS LOCATED ON A 2-HOUR FIRE RATED WALL SHALL HAVE A FIRE ALARM INTERFACE THAT INTERRUPTS 120V POWER FOR THE AUTOMATIC DOOR OPENER UNDER A FIRE ALARM CONDITION. PROVIDE (1) CONTROL MODULE FROM EACH BUILDING FIRE ALARM SYSTEM IF LOCATED ALONG THE BORDER OF TWO
BUILDINGS.
0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'
1/8" = 1'-0"
PARTIAL SECOND FLOOR FIRE ALARM AND
SECURITY PLAN - PHASE 2 1
PHASING GENERAL NOTES:
ALL WORK IN PHASE 2 SHALL BE DONE DURING OFF-HOURS. REFER TO THE GENERAL REQUIREMENTS FOR
ADDITIONAL INFORMATION.
1.
F
F
TS
WF
F
F
F
F
F
F
F
F
P
P
F
F
F
F
F
F
F
P
F
D2
D1
CR
P
TS
TS
TS
D3
F
F
F
D1
D1
D1
D1
D1
D1
D1
D1
16C 17B 18E 20A 24C 25B 26B 28B25C
C2
A1
ZZ
YY
XX
UU
RR
ss
B
D
VV
E
G1
C1
17a 24b 25a 26a 28 3119c 23b
PHASE 3 SCOPE OF WORK
X
X
X
X
X X
X
X X
X
X X X
X
X
X
X
X
X X
X X X
X
X
X X
X
X
X
X
X
X
Cart Holding
2C219
X
X
X
X
X
X
XRR
TYP
TYP
TYP
General
OR
(OR-07)
2C212
Ortho OR
(OR-08)
2C215
Clean Corridor
2C200S
Clean Corridor
2C200P
Soiled Holding
2D281
Anesthesia Office
2D282
Anesthesia Storage
2C222
Medication Prep
Room
2C219A
Ortho OR
(OR-10)
2C217
General
OR
(OR-09)
2C216
Anesthesia Workroom
2C218 Office
2D283
Office
2D284
Office
2D285
Semi-Restricted
2C200F
Scrub
2C200GBed Holding
2C200H
Scrub
2C200J Bed
Holding
2C200K
Scrub
2C200L
Bed Holding
2C200M
Electrical Room
2C213
Ortho Equipment
2C215A
Laboratory, Frozen Section
2C214
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
Patient Room #3 (Isolation)
2D127B
Anteroom
2D127A
EMS
Closet
2D110
Gas Room Non
Oxidizing
2514A
Laser Scales Video
Equipment
Toilet
2D127C
Toilet
2D263
Patient Room #4
2D111
Lounge / Dictation
2D251
Work
2D260E
Work
2D260F
Office
2D261C
Sub Sterile
General
OR-4
Storage
OR-3
Orthopedic
Elec.
2517A
Sub Sterile
Storage
OR-1
Cardiac
Pump Room
Gas Room Oxidizing
TEMP.
Implant Storage
Rm.
Stair
2S7
Office
Special Equipment Records
OR-2
Neuro
Corridor
2C100E
Dictation
2D252A
Office
Corridor
2C280
Light Room
2500I
TEMP.
Medical
Prep Rm.
Scrub
2500N Scrub
2500O
Upper Mechanical
Room
2500Q
Hybrid OR
2C366
Hybrid OR
2C366
Control
2D261
Nurse Mgr.
2D262
Stair #9
2C202
PACU EMS
2C234
Sub-Sterile
2C235
Procedure
2C231
Procedure
2C232
Procedure
2C233
Passage
2C230
PACU
Cubicle 5
2C237E
PACU
Cubicle 6
2C237F
PACU
Cubicle 4
2C237D
PACU
Cubicle 3
2C237C
PACU
Cubicle 2
2C237B
PACU
Cubicle 1
2C237A
CRNA
2D253
OI&T
Electrical Rm.
2519A
S
59459
M.P. LONG
R
E
S
O F
I
R
G E
NO
I
S
P
E
N
E
D
ERT
L EA
E I N
G
R
T
S
TE
A
H
F OO
IO
FREDRICK, FREDRICK & HELLER
ENGINEERS, INC.
672 EAST ROYALTON ROAD
BROADVIEW HTS., OHIO 44147
TEL. (440) 546-9696
FAX: (440) 546-9699
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1DESIGN AND CONSTRUCTION DOCUMENTS AS
INSTRUMENTS OF SERVICE ARE GIVEN IN
CONFIDENCE AND REMAIN THE PROPERTY OF
PERSPECTUS ARCHITECTURE. THE USE OF THIS
DESIGN AND THESE CONSTRUCTION
DOCUMENTS FOR PURPOSES OTHER THAN THE
SPECIFIC PROJECT NAMED HEREIN IS STRICTLY
PROHIBITED WITHOUT THE EXPRESSED
WRITTEN CONSENT OF PERSPECTUS
ARCHITECTURE. COPYRIGHT C 2019.
13212 Shaker Square Suite 204 Cleveland, Ohio 44120 P. 216.752.1800 F. 216.752.3833
18067
Z M y D o c u m e n ts \1
F F
H C
F R jd u a le .r v t
/2
/2
:4
:4
P
M
3-ES2-1
10701 East Blvd. Cleveland, OH 44106
06/26/2020 MPL JRD
541-19-101Renovate Operating RoomsBID ISSUEPARTIAL SECOND FLOOR F.A. AND SECURITY
DEMO PLAN - PHASE 3
N
ELECTRICAL DEMOLITION NOTES
D1 ALL EXISTING LIGHTING FIXTURES, RECEPTACLES, SPECIAL SYSTEMS OUTLETS, CONDUIT, WIRING ETC. THAT WILL NOT BE REUSED IN THE REMODELED INSTALLATION SHALL BE REMOVED UNLESS OTHERWISE NOTED. THIS DEMOLITION SHALL INCLUDE ALL ELECTRICAL ITEMS SHOWN ON THIS PLAN THAT ARE NOT DESIGNATED BY "X", "XN" OR "XRR" AND ALL OTHER ADDITIONAL ITEMS THAT ARE NOT SHOWN BUT THAT MUST BE REMOVED IN ORDER TO
PRODUCE A NEAT, FINISHED, PROPERLY FUNCTIONING ELECTRICAL INSTALLATION. MAINTAIN CIRCUIT CONTINUITY TO ALL EXISTING REUSED ELECTRICAL SYSTEMS COMPONENTS - PROVIDE ALL CONDUIT AND WIRING NECESSARY TO ACHIEVE THE SAME. THE CONTRACTOR SHALL FIELD VERIFY THE NATURE AND EXTENT OF ALL DEMOLITION
WORK AND SHALL INCLUDE COST FOR THE SAME IN THE BID SUBMITTAL.
D2 ALL EXISTING REMOVED ELECTRICAL EQUIPMENT, DEVICES, ETC. THAT ARE NOT RETAINED BY THE OWNER SHALL
BE DISPOSED OF BY THE ELECTRICAL CONTRACTOR.
D3 DASHED WALLS ON PLAN INDICATE EXISTING CONSTRUCTION TO BE REMOVED.
D4 REFER TO ELECTRICAL LEGEND FOR ALL SYMBOL DESIGNATIONS. NOTE SPECIAL ATTENTION TO SELECTED EXISTING DEVICES, WIREWAYS, ETC. MARKED XB, XRR OR XN, AND REMOVE/BLANK OFF, RELOCATE OR REPLACE
THESE COMPONENTS AS REQUIRED.
D5 MAINTAIN CIRCUIT CONTINUITY TO ALL EXISTING ELECTRICAL SYSTEM COMPONENTS IN AREAS NOT BEING REMODELED UNLESS OTHERWISE NOTED. PROVIDE ALL CONDUIT AND WIRING EXTENSIONS NECESSARY TO
ACHIEVE SAME.
D6 THE ELECTRICAL CONTRACTOR SHALL CLOSELY COORDINATE ALL ELECTRICAL DEMOLITION WORK WITH THE GENERAL AND MECHANICAL CONTRACTORS, AND SHALL DISCONNECT ALL REQUIRED CIRCUITS IN A TIMELY
MANNER.
D7 REFER TO ARCHITECTURAL PLANS FOR SPECIFIC PHASING REQUIREMENTS.
0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'
1/8" = 1'-0"
PARTIAL SECOND FLOOR FIRE ALARM AND
SECURITY DEMOLITION PLAN - PHASE 3 1
# CODED NOTES
1 REMOVE ALL FIRE ALARM, SECURITY DEVICES, JUNCTION BOXES, AND ETC. FROM PHASE 2 ARE UNLESS
OTHERWISE NOTED. REMOVE ALL ASSOCIATED CONDUIT AND WIRING COMPLETE TO SOURCE.
PHASING GENERAL NOTES:
ALL WORK IN PHASE 3 SHALL BE DONE DURING OFF-HOURS. REFER TO THE GENERAL REQUIREMENTS FOR
ADDITIONAL INFORMATION.
REFER TO ARCHITECTURAL DRAWINGS FOR SUB PHASES IN PHASE 3.
1.
2.
TS
WF
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
P
P F
F
F
F
F
F P
F
F
F
D2
D1
P
TS
TS
TS
D3
D1
D1
D1
D1
D1
D1
D1
D1
D1
D2
D1
D1
D4
F
F
16C 17B 18E 20A 24C 25B 26B 28B25C
C2
A1
ZZ
YY
XX
UU
RR
ss
B
D
VV
E
G1
C1
17a 24b 25a 26a 28 3119c 23b
PHASE 3 SCOPE OF WORK
X
X
X
X
X
X
X
X X
X X X
X
HL21
T-LL21
LL21EGB
HL22CR2
HL22CR1
LL22CR2
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
SCP
X
FACP
X
X
X
X X
X
X
X
XX
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Soiled Holding
2D281 Cart
Holding
2C219
Medication Prep
Room
2C219A
Anesthesia Storage
2C222
Anesthesia Office
2D282
Implant
2D253
Dictation
2D251B
Anesthesia Workroom
2C218
Office
2D283
Office
2D284
Office
2D285
Alcove
2C200Q
Alcove
2C200R
Clean Corridor
2C200P
Clean Corridor
2C200S
General
OR
(OR-07)
2C212
Bed Holding
2C200C
Scrub
2C200B
General
OR (OR-6)
2C210
Robotic
OR (OR-5)
2C114
Bed Holding
2C100C
Scrub
2C100D
OI&T
2C122 Electrical
Room
2C115
Clean Corridor
2C100H
Cardiac
OR (OR-2)
2C126
Bed Holding
2C100PScrub
2C100Q
Scrub
2C100U
EMS
Closet
2D280
Alcove
2C100N
Cardiac
OR (OR-1)
2C129
Alcove
2C100M
Ortho OR
(OR-10)
2C217
General
OR
(OR-09)
2C216
Ortho OR
(OR-08)
2C215
Laboratory, Frozen Section
2C214
Ortho Equipment
2C215A
Electrical Room
2C213
Bed Holding
2C200H
Scrub
2C200G Scrub
2C200J Bed
Holding
2C200K
Scrub
2C200L Bed
Holding
2C200M
Semi-Restricted
2C200F
Procedure
2C231
Procedure
2C232
Passage
2C230
Sub-Sterile
2C235
Procedure
2C233
HAC
2C224
PACU EMS
2C234
PACU
Cubicle 1
2C237A
PACU
Cubicle 2
2C237B
PACU
Cubicle 3
2C237C
PACU
Cubicle 4
2C237D
Cardiac Equipment
2C127
Cardiac Pump Room
2C128
Alcove
2C100K
Clean Corridor
2C100J
Immediate Use
Sterilization Room
2C123
Robotic Equipment
Storage
2C213
Equipment Storage
2C112
Anesthesia Storage
2C111
Gas Room
2C211
EMS
2C110
Semi-Restricted
2C100B
X
X
Office
2D261C
Control
2D261
S
59459
M.P. LONG
R
E
S
O F
I
R
G E
NO
I
S
P
E
N
E
D
ERT
L EA
E I N
G
R
T
S
TE
A
H
F OO
IO
FREDRICK, FREDRICK & HELLER
ENGINEERS, INC.
672 EAST ROYALTON ROAD
BROADVIEW HTS., OHIO 44147
TEL. (440) 546-9696
FAX: (440) 546-9699
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
1DESIGN AND CONSTRUCTION DOCUMENTS AS
INSTRUMENTS OF SERVICE ARE GIVEN IN
CONFIDENCE AND REMAIN THE PROPERTY OF
PERSPECTUS ARCHITECTURE. THE USE OF THIS
DESIGN AND THESE CONSTRUCTION
DOCUMENTS FOR PURPOSES OTHER THAN THE
SPECIFIC PROJECT NAMED HEREIN IS STRICTLY
PROHIBITED WITHOUT THE EXPRESSED
WRITTEN CONSENT OF PERSPECTUS
ARCHITECTURE. COPYRIGHT C 2019.
13212 Shaker Square Suite 204 Cleveland, Ohio 44120 P. 216.752.1800 F. 216.752.3833
18067
Z M y D o c u m e n ts \1
F F
H C
F R jd u a le .r v t
/2
/2
:4
:1
P
M
3-ES2-2
10701 East Blvd. Cleveland, OH 44106
06/26/2020 MPL JRD
541-19-101Renovate Operating RoomsBID ISSUEPARTIAL SECOND FLOOR F.A. & SECURITY
PLAN - PHASE 3
N
FIRE ALARM GENERAL NOTES
F1 ALL FIRE ALARM SYSTEM DEVICES SHALL BE CONNECTED COMPLETE TO THE MAIN FIRE ALARM SYSTEM CONTROL
PANEL IN ACCORDANCE WITH ENGINEER APPROVED MANUFACTURER'S SHOP DRAWING WIRING DIAGRAMS AND
DETAILS.
F2 ALL FIRE ALARM SYSTEM CONDUCTORS SHALL BE INSTALLED IN 3/4" MINIMUM SIZE CONDUIT SYSTEM.
F3 IN GENERAL ALL MANUAL PULL STATIONS SHALL BE INSTALLED AT 48" ABOVE FINISHED FLOOR. MANUAL PULL STATIONS SHALL BE INSTALLED WITHIN 5'-0" OF ALL EXIT DOORWAY OPENINGS AT EACH EXIT ON EACH FLOOR.
ADDITIONAL MANUAL PULL STATIONS SHALL BE PROVIDED SO THAT THE TRAVEL DISTANCE TO THE NEAREST PULL
STATION WILL NOT EXCEED 200' MEASURED HORIZONTALLY ON THE SAME FLOOR.
F4 ALL AUDIO/VISUAL AND VISUAL ONLY FIRE ALARM SYSTEM DEVICES SHALL BE ADA TYPE. IN ALL CASES VISUAL DEVICES SHALL BE WALL MOUNTED AT 80" ABOVE FINISHED FLOOR. VISUAL DEVICES SHALL BE LOCATED NOT MORE THAN 15' FROM THE END OF ALL CORRIDORS WITH A SEPARATION NOT GREATER THAN 100' BETWEEN DEVICES. AUDIO DEVICES SHALL BE INSTALLED THROUGHOUT THE BUILDING TO ATTAIN MINIMUM DECIBEL LEVELS REQUIRED BY CODE. COMBINATION AUDIO/VISUAL DEVICES AND ADDITIONAL VISUAL ONLY DEVICES SHALL BE
INSTALLED AT LOCATIONS AS INDICATED ON FLOOR PLANS.
F5 IN GENERAL SMOKE DETECTORS SHALL BE INSTALLED ON CEILINGS WITH SPACING NOT TO EXCEED
MANUFACTURER'S RECOMMENDATION.
F6 SPRINKLER SYSTEM WATERFLOW ALARM INITIATING DEVICES SHALL BE CONNECTED COMPLETE TO THE FIRE
ALARM SYSTEM.
F7 DUCT TYPE SMOKE DETECTORS SHALL BE PROVIDED FOR ALL HVAC RETURN AIR SYSTEMS WITH DESIGN CAPACITY GREATER THAN 2,000 CFM. WHERE RETURN AIR RISERS SERVE TWO OR MORE STORIES, AND ARE PART OF A RETURN AIR SYSTEM HAVING A DESIGN CAPACITY GREATER THAN 15,000 CFM, DUCT DETECTORS SHALL BE PROVIDED AT EACH STORY. COORDINATE EXACT DETECTOR LOCATIONS AND PROVISION OF ADEQUATE DUCT
LENGTHS WITH THE MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN.
F8 PROVIDE ALL FIRE ALARM SYSTEM COMPONENTS NECESSARY FOR SHUT DOWN OF HVAC EQUIPMENT BY THE FIRE
ALARM SYSTEM WHERE SAME IS REQUIRED.
F9 PROVIDE ALL FIRE ALARM SYSTEM COMPONENTS NECESSARY FOR ELEVATOR CAPTURE BY THE FIRE ALARM
SYSTEM WHERE SAME IS REQUIRED.
F10 SMOKE DETECTORS SHALL BE INSTALLED WITHIN 5'-0" OF CENTERLINE OF SMOKE DOORS ON HOLD-OPEN.
F11 SMOKE DETECTORS SHALL NOT BE LOCATED CLOSER THAN 3'-0" FROM AN AIR SUPPLY DIFFUSER.
F12 AUTOMATIC DOORS LOCATED ON A 2-HOUR FIRE RATED WALL SHALL HAVE A FIRE ALARM INTERFACE THAT INTERRUPTS 120V POWER FOR THE AUTOMATIC DOOR OPENER UNDER A FIRE ALARM CONDITION. PROVIDE (1) CONTROL MODULE FROM EACH BUILDING FIRE ALARM SYSTEM IF LOCATED ALONG THE BORDER OF TWO
BUILDINGS.
0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'0' 4' 8' 16' 32'
1/8" = 1'-0"
PARTIAL SECOND FLOOR FIRE ALARM AND
SECURITY PLAN - PHASE 3 1
# CODED NOTES:
CONNECT ALL NEW FIRE ALARM DEVICES TO EXISTING FIRE ALARM TERMINAL CABINET IN TELECOM ROOM 2-C363.
CONNECT ALL NEW SECURITY DEVICES AND SECURITY CAMERA TO EXISTING LENEL CONTROL PANEL IN TELECOM ROOM 2-C363. REFER TO DRAWING 0-ES1-2 AND 0-ES1-3 FOR ADDITIONAL INFORMATION.
PHASING GENERAL NOTES:
ALL WORK IN PHASE 3 SHALL BE DONE DURING OFF-HOURS. REFER TO THE GENERAL REQUIREMENTS FOR
ADDITIONAL INFORMATION.
REFER TO ARCHITECTURAL DRAWINGS FOR SUB PHASES IN PHASE 3.
1.
2.
| 18067 FFH CF R19_jduale |
| 0-ES1-1 - ELECTRONIC SAFETY AND SECURITY LEGEND & NOTES |
| 3-ES2-2 - PARTIAL SECOND FLOOR F.A. & SECURITY PLAN - PHASE 3.pdf |
| 18067 FFH CF R19_jduale |
| 3-ES2-2 - PARTIAL SECOND FLOOR F.A. & SECURITY PLAN - PHASE 3 |
| 3-ES2-1 - PARTIAL SECOND FLOOR F.A. AND SECURITY DEMO PLAN - PHASE 3.pdf |
| 18067 FFH CF R19_jduale |
| 3-ES2-1 - PARTIAL SECOND FLOOR F.A. AND SECURITY DEMO PLAN - PHASE 3 |
| 2-ES2-2 - PARTIAL SECOND FLOOR F.A. & SECURITY PLAN - PHASE 2.pdf |
| 18067 FFH CF R19_jduale |
| 2-ES2-2 - PARTIAL SECOND FLOOR F.A. & SECURITY PLAN - PHASE 2 |
| 2-ES2-1 - PARTIAL SECOND FLOOR F.A. & SECURITY DEMO PLAN - PHASE 2.pdf |
| 18067 FFH CF R19_jduale |
| 2-ES2-1 - PARTIAL SECOND FLOOR F.A. & SECURITY DEMO PLAN - PHASE 2 |
| 0-ES1-3 - ACCESS CONTROLLED DOOR DETAILS AND NOTES.pdf |
| 18067 FFH CF R19_jduale |
| 0-ES1-3 - ACCESS CONTROLLED DOOR DETAILS AND NOTES |
| 0-ES1-2 - ACCESS CONTROL SYSTEM RISER, DIAGRAM, AND NOTES.pdf |
| 18067 FFH CF R19_jduale |
| 0-ES1-2 - ACCESS CONTROL SYSTEM RISER, DIAGRAM, AND NOTES |
File details come from the government source that posted it. Updated .