S02 - Attachment 2 - Lake Nona Canteen Design Drawings.pdf
PDF 27 MB Posted
- Solicitation number
- 36C24825R0036
About this file
These documents are architectural, mechanical, electrical, and plumbing design drawings for renovating the Lake Nona VA Medical Center Canteen facility in Orlando, Florida. The project, identified as VA Project 675-23-103, involves a comprehensive renovation of approximately 22,777 square feet on the first floor, focusing on modernizing the food service and support spaces. The renovation includes demolishing existing equipment, reconfiguring kitchen and tray line areas, installing new food preparation and dishwashing equipment, and updating electrical, mechanical, and plumbing systems.
Key details include a phased construction approach with specific demolition and installation stages, new equipment such as a warewasher, tray line equipment, refrigerated units, and hot food tables, and provisions for electrical, plumbing, and HVAC infrastructure. The project is set for completion by August 22, 2024, with a site visit scheduled for April 14, 2025. The solicitation (36C24825R0036) is designated for Service-Disabled Veteran-Owned Small Businesses (SDVOSB), with a project magnitude between $1,000,000 and $5,000,000, and requires compliance with Davis-Bacon wage determinations and specific safety and environmental standards.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
-0 2-
:1 3:
P
M
PROJECT 675-23-103
RENOVATE BUILDING 2 FOR CANTEEN
VA MEDICAL CENTER, ORLANDO, FL
3603 NW 98TH ST, SUITE B
GAINESVILLE, FLORIDA 32606
PH: (352) 474-6124
FAX. (352) 553-4437
DESIGNED BY:
PROJECT AREA
(LEVEL 1)
3603 NW 98th Street, Suite B Gainesville, FL 32606 Phone: (352) 474-6124 Fax: (352) 553-4437
COA: FL #29758
AKEA Design Project No. AD213-23
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 10
RENOVATE LAKE NONA
BUILDING 2 FOR CANTEEN
ORLANDO, FLORIDA
AUGUST 22, 2024
Revisions: Date:
Office of Construction and Facilities Management
ARCHITECT/ENGINEER OF RECORDCONSULTANT
A
B
C
D
E
F
675-23-103FINAL CONSTRUCTION
DRAWINGS
FINAL DESIGN SUBMITTAL
TITLE PAGE, LOCATION MAP,
AND INDEX OF DRAWINGS
G001
AUGUST 22, 2024
DESIGNED FOR:
ORLANDO VA MEDICAL CENTER
2500 LAKEMONT AVE.
ORLANDO, FL 32803
Digitally signed by Jennifer R Fong Date: 2024.08.28 16:57:47-04'00'
UPUP
UP
UP
DN
C
E
E1
C
UPUP
UP
UP
DN
F
G
H
J
K
L
2627282930313233
32.3
EXIT
PHASE 4
PHASE 2
PHASE 3
PHASE 3
PHASE 4A
NIC
NIC
NIC
PHASE 1
PHASE 3
1NC06
CORRIDOR
1N605
TOILET
1N607
TOILET
1N608
ASST CHIEF (FOOD)
1G304
RETAIL STORAGE
1G304a
HAC
1P108
INTERNSHIP
1P109
DIET TECH/ INTERN
DIRECTOR
1PC01
AISLE
1PC01a
TRAINING AREA
1P111
DIET TECH
1P110
ASSIST. CHIEF
1P106
CHIEF CANTEEN
1P606
CLEANING EQUIP
1P608
HAC
1P602
SANITARY SUPPLY
1PE01
ELEVATOR 1PE02
ELEVATOR
1PC06
CORRIDOR
1PS01
STAIR
1HC03
CORRIDOR
1PC06a
ELEV LOBBY
1VC07
AISLE
1P601a
CART/CAN WASH
1P601
DISHWASH
1V721
EXTRACTOR
1V712
RECEIVING
1V712a
RECEIVING OFFICE
1V802
BULK CARTS
STAGING
1V708
RETHERM
1V704
MEAL
CARTS/REFRIGERATOR
1V803
BULK
REFRIGERATED
STORAGE
1V805
VENDING STORAGE
1V805a
VENDING COOLER
1V806
REFRIGERATION/
COMPRESSOR
ROOM
1V702
TRAY ASSEMBLY
1V101
FOOD PRODUCTION
1V103
REFRIGERATED
STORAGE
1V105
FREEZER
1V103
REFRIGERATED
STORAGE
1V101b
POT/PAN WASH
1V110
INGREDIENT ROOM
1VC08
AISLE
1V811
ELEC
1V809
ELEC
1V112
DRY STORAGE
1V112b
COMM
1V112a
ELEC
1V812
NON-FOOD
STORAGE
1V811a
ELEC
1V104
SERVERY
1VS01
STAIR
1V104b
PIZZA OVEN
1U501a
CONSULT
1T821
CLOSET
1P601c
SANITARY SUPPLY
1P103
PROGRAM
MANAGER
1P105
NUTRITION
THERAPY
1P107
CHIEF FNS
1PC02
CORRIDOR
1V101a
DAY COOLER
1U301
COMM
1U501c
HAC
1U302
HAC
1U501b
O.P. SECURE
PRESCRIPTION
STORAGE
1U303
ELEC
1V102
SODA CLOSET
1US01
STAIR - PHARMACY
OMELET LUNCH
STATION
ASIAN
FOOD
ABSO FRUITLY
BAKER
PIZZA - FUTURE
SELF CONTAIN
BUT CURRENTLY
SOME IN
STORAGE
GRILL SELF
CONTAINED
COOKING
HERE
ENTREE
AND SIDES
ABSO FRUITLY
PIZZA PREP-
MIGHT NOT BE
HERE BY
CONSTRUCTION
TIME
BAKER
ASIAN PREP
BAKER
OMELET LUNCH PREP
ENTREE & SIDES PREP
TRAY LINE USES
THIS SPACE
ABSO
FRUITLY
ASIAN PREP
TRAY LINE PREP
KETTLES
NURSE
HOME
FOOD
PREP
1V104a
OPEN OFFICE
PHASE 4B
PHASE 4
B
PHASE 3
PHASE 3
PHASE 3
PHASE 4
PHASE 1
PHASE 2 AND 4
PHASE 1
PHASE 1
PHASE 2
PHASE 3
PHASE 3
DEDUCT
ALTERNATE #1
1V705
COMM
1V703
ELEC
1V106
DETERGENT RM
GENERAL NOTES:
1. CONTRACTOR TO CONFIRM PHASING WITH VA COR
AND COORDINATE/ VERIFY LEAD TIME FOR THE NEW
KITCHEN EQUIPMENT. VERIFY ANY PHASE
CONFLICTS AND ATTAIN GOVERNMENT APPROVAL
FOR PHASING PLAN.
2. PROVIDE TEMPORARY DUST PROOF PARTITIONS AS
REQUIRED PER SECTION 01 35 26 SAFETY
REQUIREMENTS TO PROTECT ALL EXISTING AREAS
FROM DEMOLITION AND NEW
CONSTRUCTION.
3. FIELD VERIFY ALL CONDITIONS. PROTECT ALL ITEMS
THAT WILL REMAIN IN PLACE. COORDINATE ALL
WORK WITH OWNER TO MINIMIZE DISRUPTION TO
EXISTING FACILITY OPERATIONS.
4. CONTRACTOR TO VERIFY LOCATION OF EXISTING
UTILITIES PRIOR TO START OF DEMOLITION.
PROTECT UTILITIES TO REMAIN IN SERVICE.
5. COORDINATE SALVAGE ITEMS TO OWNER WITH THE
SPECIFICATIONS AND OWNER'S REPRESENTATIVE
(COR).
6. CONTRACTOR TO PATCH, REPAIR AND PAINT
(REFINISH) SURFACES AND BUILDING ELEMENTS
DAMAGED BY ADDITION OR REMOVAL OF
MECHANICAL AND ELECTRICAL ITEMS. PATCH AND
REPAIR ALL SURFACES TO MATCH EXISTING
SURFACES. FIELD VERIFY EXTENT OF REQUIRED
REPAIRS.
7. EXISTING LIFE SAFETY EXIT ROUTES TO REMAIN
UNOBSTRUCTED. COORDINATE WITH MEP
DRAWINGS.
PHASE 3
PHASE 2
PHASE 1
VA WORKSTATIONS (FOR
REFERENCE ONLY)
PHASING LEGEND:
NOT IN CONTRACT
SCOPE LEGEND:
PHASE 4
3603 NW 98th Street, Suite B Gainesville, FL 32606 Phone: (352) 474-6124 Fax: (352) 553-4437
COA: FL #29758
AKEA Design Project No. AD213-23
Design, Inc.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE LAKE NONA
BUILDING 2 FOR CANTEEN
ORLANDO, FLORIDA
OF
ARCHITECT - OF - RECORD FL. REG. NO.
675-23-103
FINAL CONSTRUCTION
DRAWINGS
This item has been electronically signed and sealed by the individual named at right.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
8/
/2
1:
:0
PM
JRF SNG
JENNIFER R. FONG AR97191
G-002
LEVEL 1, AREA D3 - CONSTRUCTION PHASING
PLAN
2 69AUGUST 22, 2024
SCALE: 1/8" = 1'-0"1 LEVEL 1, AREA D3 - CONSTRUCTION PHASING PLAN
E1 E2 E3
E4
C1
A3 A2
A1 B1
B2
CLINIC
HOSPITAL
D1 D2 D3
D4 D5 D6
P-W P-E
A4
W
KEY PLAN
NTS
W
ALL PHASES:
1. ALL CONSTRUCTION DEMOLITION (TEMPORARY AND
PERMANENT AS APPLICABLE, BUT NOT FLOORING) TO BE
COMPLETED BEFORE FLOORING FINISH INSTALLATION.
2. FLOORING FINISH INSTALLED AFTER PREPARATION OF
SURFACES AND FLOOR SLOPES ARE COMPLETED.
3. ONCE FLOORING IS CURED, EXISTING EQUIPMENT AND
PLUMBING FIXTURES TO BE REINSTALLED. NEW EQUIPMENT TO
BE INSTALLED WHERE APPLICABLE.
4. CONTRACTOR TO STORE, PROTECT & REINSTALL ALL EXISTING
CONNECTIONS, FIXTURES AND EQUIPMENT AFTER FLOOR
FINISH REPLACEMENT.
5. MOLD REMEDIATION PER CIH REPORT TO BE PERFORMED AS
NEEDED PER PHASE.
6. ALL WORK TO BE PERFORMED AFTER HOURS FROM 8 PM TO
4:30 AM, NO DAYTIME WORK ALLOWED ON ANY PHASES.
7. ICRA BARRIERS TO REMAIN IN PLACE FOR THE DURATION OF
THE PHASE.
8. CONSTRUCTION EGRESS TO BE CONFIRMED FOR EACH PHASE
WITH THE VA.
PHASE 1:
1. REAR DISHWASHER AND CART WASH DEMOLITION AND NEW
SURFACES.
2. PULPER DEMOLITION & PIPE PREPARATIONS PER PLUMBING
REQUIREMENTS. CURB DEMOLITION AND REFINISH ROOM.
3. SUSHI AREA INSTALLATION FOR TEMPORARY TRAY LINE
UTILITIES, REMOVE WALL PREPARATION SINKS, AND RETURN
TO VA. INSTALL UTILITIES FOR TEMPORARILY RELOCATED
EXISTING TRAY LINE EQUIPMENT AND REFINISH WALLS WHERE
DISTURBED TO MATCH ADJACENT EXISTING.
4. INSTALL NEW FLOORING IN THIS AREA.
5. COORDINATE WITH VA FOR COOKING SHUT DOWN SCHEDULES.
6. OCCUPANT'S EXIT THROUGH 1PC06 & 1V712 DURING THIS
PHASE.
PHASE 2:
1. RETHERM 1V708 RENOVATION TO ADD TEMPORARY UTILITIES,
WALL AND DOOR FOR TEMPORARY OFFICE LOCATION.
2. DEMOLITION AND CONSTRUCTION OF 1V104A WAREWASH ONCE
REAR DISHWASHER 1P601 IS IN SERVICE.
3. VA TO SHIFT KITCHEN WORK ON COOKING SIDE OF KITCHEN
ONCE SUSHI AREA HAS BEEN FINISHED TO MOVE TEMPORARY
TRAY LINE THERE.
4. OFFICES CORRIDOR AND TRAINING AREA FINISHES (FLOOR AND
CEILINGS) REPLACED DURING NIGHTS ONLY. CORRIDOR AND
EXISTING SINGLE OFFICES TO REMAIN ACCESSIBLE AND IN USE
DURING DAYTIME WORKING HOURS.
5. OCCUPANT'S EXIT THROUGH 1PC06 & 1V712 DURING THIS
PHASE.
PHASE 3:
1. OFFICES DEMOLITION AND CONSTRUCTION OF NEW OFFICES.
2. REAR STORAGES, POTS AND PANS AND PATH THROUGH
ELEVATORS EXIT.
3. 1V105 FREEZER, 1V806 REFRIGERATION, 1V803 BULK
REFRIGERATED STORAGE & 1V805 VENDING STORAGE &
COOLER TO BE COORDINATED WITH VA FOR ACTIVATION
RENTALS.
4. 1V104 SERVERY RETAIL FOOD SERVICE AND DRINK COUNTER
TO BE COORDINATED WITH VA.
5. OCCUPANT'S EXIT THROUGH 1PC02 DURING THIS PHASE.
PHASE 4:
1. DEMOLISH TEMPORARY OFFICE UTILITIES, WALL & DOOR IN
RETHERM 1V708.
2. REPLACE FLOOR IN ONE (1) COOLER/FREEZER FLOOR
REPLACEMENT AT A TIME SO THAT GOODS CAN BE MOVED TO
OTHER COOLERS OR FOR THE RENTAL REDUCTION.
3. 1V704 MEAL CARTS/REFRIGERATOR & 1V103 REFRIGERATED
STORAGE TO BE COORDINATED WITH VA FOR ACTIVATION
RENTALS.
4. 1V104 SERVERY RETAIL CENTER ISLAND AND DRINK COUNTER
TO BE COORDINATED WITH VA.
5. OCCUPANT'S EXIT THROUGH 1PC02 DURING THIS PHASE.
1P106
ALL PHASES:
PHASE 1:
PHASE 2:
PHASE 3:
PHASE 4: CONSTRUCTION EGRESS
Revisions: Date:
Date: 2024.08.28 16:58:43-04'00'
C
G
H
272829
1VC07
AISLE
1V704
MEAL
CARTS/REFRIGERATOR 1V802
BULK CARTS
STAGING
1V806
REFRIGERATION/
COMPRESSOR
ROOM
1V101c
BLAST CHILLER
1PC06a
ELEV LOBBY
1VC08
AISLE
12 12
1V708
TEMPORARY OFFICE
TEMPORARILY
RELOCATED
EXISTING
TRAYLINE
SEE G002
1V702
TEMPORARY
TRAYLINE
A3B
TEMP
6' - 0"
KITCHEN FLOORING PER AF-121.
REPLACE COUNTER TOP TO MATCH EXISTING MATERIAL AND
FINISHES. REFER TO DETAILS AND ELEVATIONS.
REPLACE TRAY LINE. REFER TO C&T DESIGN EQUIPMENT CO.
INC PLAN FOR LOCATION AND CONFIGURATION.
REPLACE FOOD MURAL IN WALL COVERING. COORDINATE
WITH INTERIOR DESIGN FOR SPECIFIC SELECTION.
REPLACE DISHWASH EQUIPMENT PER C&T DOCUMENTS.
PROPOSED FLOOR PLAN NOTES
1. REFER TO C&T PLANS IN K SHEETS AND C&T
DOCUMENTS IN SPECIFICATIONS FOR MORE
INFORMATION FOR EXACT LOCATIONS AND
CONFIGURATIONS FOR THE NEW EQUIPMENT.
2. REFER TO TEMPORARY LAYOUT FOR THE PROPOSED
OFFICE LOCATION ON SHEET G-003.
3. REFER TO MEP DRAWINGS FOR MORE INFORMATION.
4. REFER TO ENLARGED LAYOUTS FOR MORE DETAILS IN
REGARD FURNITURE AND EQUIPMENT.
5. REFER TO SPECIFICATIONS FOR WALL PROTECTION
INFORMATION.
6. REFER TO AE-502 FOR SLAB AND INTERSTITIAL FLOOR
DETAILS.
KEYNOTES NOTES
NOT IN CONTRACT
SCOPE LEGEND
PLACEMENT OF CARD READER (CR) LOCATION.
HAND SINKS. COORDINATE WITH K SHEETS AND
MECHANICAL/ PLUMBING FOR ADDITIONAL
INFORMATION.
REINSTALL COMMERCIAL SINKS.
PLACE OFFICE TEMPORARY WALL, DOOR, AND
OFFICE FURNITURES/ EQUIPMENT IN THE RETHERM
DURING CONSTRUCTION PHASING PERIOD FOR
TEMPORARY PLACEMENT.
WALL PROTECTION OVER EXISTING WALL.
REINSTALL EXISTING EQUIPMENT/ PLUMBING
FIXTURES AFTER FOR FLOOR FINISH PLACEMENT.
COORDINATE WITH MECHANICAL AND ELECTRICAL
FOR ADDITIONAL DETAILS.
FURRED WALL PLACEMENT WITH HAND SINK AND
EYEWASH STATION.
FINISHES TO MATCH ADJACENT EXISTING EACH SIDE.
EDGE OF EXISTING WALL TO REMAIN.
PLACE CORNER GUARD.
SEE ELECTRICAL FOR UNISTRUT INSTUCTIONS.16
3603 NW 98th Street, Suite B Gainesville, FL 32606 Phone: (352) 474-6124 Fax: (352) 553-4437
COA: FL #29758
AKEA Design Project No. AD213-23
Design, Inc.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE LAKE NONA
BUILDING 2 FOR CANTEEN
ORLANDO, FLORIDA
OF
ARCHITECT - OF - RECORD FL. REG. NO.
675-23-103
FINAL CONSTRUCTION
DRAWINGS
This item has been electronically signed and sealed by the individual named at right.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
8/
/2
1:
:1
PM
JRF SNG
JENNIFER R. FONG AR97191
G-003
LEVEL 1, AREA D3 - TEMPORARY PHASING
PLAN
3 69AUGUST 22, 2024
SCALE: 1/4" = 1'-0"1 LEVEL 1, AREA D3 - TEMPORARY PHASING PLAN
E1 E2 E3
E4
C1
A3 A2
A1 B1
B2
CLINIC
HOSPITAL
D1 D2 D3
D4 D5 D6
P-W P-E
A4
W
KEY PLAN
NTS
W
Revisions: Date:
Date: 2024.08.28 16:59:33-04'00'
3'-6"
5' -0
5'
-0
CL
UP
UP
UPUP
UP
UP
DN
UP
DN
UP
UP
UPUP
UP
UP
DN
UP DN
S
C
E
E1
C
THIS PROPOSED PROJECT WILL RENOVATE
22,777 SF OF EXISTING SPACE ON THE 1ST FLOOR OF THE LAKE NONA
CANTEEN TO PROVIDE SPACE FOR CANTEEN INCLUDING SUPPORT SPACES.
CLASSIFICATION OF WORK - REMODELING TO AN EXISTING HOSPITAL.
1. OCCUPANCY CLASSIFICATION: EXISTING HOSPITAL
CHAPTER 19 NFPA 101
2. CONSTRUCTION TYPE - (NFPA TYPE II (222))
3. BUILDING HEIGHTS AND AREAS
HEIGHT - UNLIMITED
NUMBER OF STORIES - UNLIMITED
AREA, PER FLOOR - UNLIMITED
4. FIRE RESISTANCE AND PROTECTION
BUILDING ELEMENT HOURLY RATING
PRIMARY STRUCTURAL FRAME EXSTING TO REMAIN
BEARING EXTERIOR WALLS EXSTING TO REMAIN
BEARING INTERIOR WALLS EXSTING TO REMAIN
NONBEARING EXTERIOR WALLS EXSTING TO REMAIN
NONBEARING INTERIOR WALLS EXSTING TO REMAIN
FLOOR EXSTING TO REMAIN
ROOF EXSTING TO REMAIN
SPRINKLERED - YES TYPE - WET PIPE, TYPICAL
FIRE ALARM - YES
CURRENT PROJECT DOES NOT MODIFY EXISTING PATH OF EGRESS
6. ACCESSIBILITY
100% ACCESSIBLE - YES
VERTICAL ACCESSIBILITY - N.A.
PROJECT INFORMATION
LIFE SAFETY NOTES
1. FIRE RESISTANCE RATED PARTITIONS ARE INDICATED
WITH LINE TYPES AS DEFINED IN THE LEGEND.
PROTECT FIRE RESISTANCE RATED PARTITION
PERIMETER JOINTS AND PENETRATIONS WITH UL
TESTED SYSTEMS TO MAINTAIN RATING INDICATED.
2. REFER TO FIRE-PROTECTION SPRINKLER AND FIRE
ALARM SPECIFICATIONS AND DRAWINGS FOR
ADDITIONAL INFORMATION.
3. EXISTING FIRE EXTINGUISHERS CABINETS TO REMAIN
UNDISTURBED. NEW FEC TO MATCH EXISTING.
APPLICABLE CODES
BUILDING CODE:
2021 INTERNATIONAL BUILDING CODE,
2021 FIRE CODE: NFPA 1, FIRE CODE,
2021 LIFE SAFETY CODE: NFPA 101, LIFE SAFETY CODE,
NATIONAL ELECTRIC CODE: NFPA 70,
2021 ACCESSIBILITY CODE: ARCHITECTURAL BARRIERS ACT
ACCESSIBILITY STANDARDS (ABAAS) INCLUDING VA SUPPLEMENT,
BARRIER FREE DESIGN STANDARD (PG-18-13) REV. 11/1/2022
VA TIL STANDARDS 2023
JURISDICTION
Building Code Authority: Department of Veterans Affairs Fire Code Authority: Department of Veterans Affairs
TD = TRAVEL DISTANCE TO EXIT
CPT = COMMON PATH TRAVEL
B
C
D
F
G
H
J
K
L
262728293031323334353637
1.12.13.14.15.16.17.13.2 2.2
C.2
D.2
B.2
C.1
D.1
B.11.2 8.12.0 7.3 1.72.7
32.3
EXISTING EXIT
N.I.C.
N.I.C.
N.I.C.
N.I.C.
N.I.C.
N.I.C.
H-1
EXISTING
TD=117'- 9"
EX
IS
TI
N
G
TD
=1
8"
EXISTING
TD=141'- 8"
H-2
EXISTING
EXIT
EXISTING
EXIT
EXIT
778 SF
Area
600 SF
Area
21281 SF
Area
76 SF
Area
42 SF
Area
1N601
CANTEEN RETAIL
FEC
EX
IS
T.
FE
C
EXIST.
FEC
EX
IS
T.
FE
C
FEC
EXIST.
FEC
EXIST.
FEC
1PC01a
TRAINING AREA
1V101
FOOD PRODUCTION
1VC07
AISLE
1V702
TRAY ASSEMBLY
1P106
CHIEF CANTEEN1PC02
CORRIDOR
1PC01
AISLE
1V803
BULK
REFRIGERATED
STORAGE
1V805a
VENDING COOLER
1V805
VENDING STORAGE
1V712
RECEIVING
1P601c
SANITARY SUPPLY
1P601
DISHWASH
1V721
EXTRACTOR
1V802
BULK CARTS
STAGING
1V708
RETHERM
1V704
MEAL
CARTS/REFRIGERATOR
1V101c
BLAST CHILLER
1V101b
POT/PAN WASH
1V105
FREEZER
1V103
REFRIGERATED
STORAGE
1V104
SERVERY
1VC08
AISLE
1P601a
CART/CAN WASH
1PC06a
ELEV LOBBY
1V806
REFRIGERATION
1PC06
CORRIDOR
1V101a
DAY COOLER
1P108
INTERNSHIP
1P111
DIET TECH
1P110
ASSIST. CHIEF
1P109
DIET TECH/ INTERN
DIRECTOR
1P104
STORAGE
1V104a
OPEN OFFICE
1V712a
RECEIVING OFFICE
1P107
CHIEF FNS
1P105
NUTRITION
THERAPY
1P103
PROGRAM
MANAGER
DEDUCT
ALTERNATE #1
1-HR FIRE/SMOKE
-STORAGE ROOMS
-CLEAN SUPPLY ROOMS
-SOIL HOLD
-LARGER THAN 100SF
2-HR FIRE/SMOKE
(TRAVEL DISTANCE 300' OR LESS)
- SMOKE BARRIER
2-HR FIRE
-STAIRS
-FLOOR TO FLOOR OPENINGS
-OCCUPANCY SEPARATION
EXIT LIGHT - SINGLE FACE
EXIT LIGHT - DIRECTIONAL (ONE
WAY)
EXIT LIGHT - DIRECTIONAL (TWO
WAY)
EXIT LIGHT - DOUBLE FACE
EXIT PATH
DISTANCE TO SMOKE PARTITION OR
EXIT
FEC FIRE EXTINGUISHER CABINET
(WITHIN 75' OF ANY POINT)
EXIT
3603 NW 98th Street, Suite B Gainesville, FL 32606 Phone: (352) 474-6124 Fax: (352) 553-4437
COA: FL #29758
AKEA Design Project No. AD213-23
Design, Inc.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE LAKE NONA
BUILDING 2 FOR CANTEEN
ORLANDO, FLORIDA
OF
ARCHITECT - OF - RECORD FL. REG. NO.
675-23-103
FINAL CONSTRUCTION
DRAWINGS
This item has been electronically signed and sealed by the individual named at right.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
8/
/2
1:
:4
PM
JRF SNG
JENNIFER R. FONG AR97191
G-004
LEVEL 1, AREA D3 - LIFE SAFETY PLAN
4 69AUGUST 22, 2024
SCALE: 1/16" = 1'-0"1 LEVEL 1, AREA D3 - LIFE SAFETY PLAN
E1 E2 E3
E4
C1
A3 A2
A1 B1
B2
CLINIC
HOSPITAL
D1 D2 D3
D4 D5 D6
P-W P-E
A4
W
KEY PLAN
NTS
W
• HOSPITAL AREA- 155,287 SF
• CANTEEN SCOPE AREA- 22,777 SF
Revisions: Date:
Date: 2024.08.28 17:05:54-04'00'
COMPRESSED CARPET 1/4" MAX BELOW THRESHOLD
THRESHOLD
A. TRANSITION BETWEEN FLOOR FINISHES
B. THRESHOLD
C. LEVEL CHANGES
FFL
SIGN POST
CONSTRUCTION
ACCESSIBLE
ROUTE WALK
PROTRUDING OBJECT
FREESTANDING OBJECT MOUNTED ON POSTS OR PYLON MAY
OVERHANG 12"MAX FROM 27" TO 80"ABOVE FINISH FLOOR
OBJECT PROJECTION FROM WALL BETWEEO 27" TO 80" ABOVE
FINISH FLOOR SHALL PROTRUDE NO MORE THAN 4"
ACCESSIBLE ROUTE
OBJECT PROJECTION FROM WALL LESS THAN 27" ABOVE
FINISH FLOOR MAY PROTRUDE ANY AMOUNT
FLOOR SHALL BE SLIP-RESISTANT SURFACE AND LEVEL
WITH MAX 1/4" CHANGE IN LEVEL
MENWOMEN RESTROOM
"C" "B" "A"
1 1/2 O.D. GRAB BAR -1 1/2"
FROM WALL-3'-6" LONG MTD.
12" FROM BACK WALL
H.C. URINAL
GRAB
BAR
SOAP
DISPENSER
ALIGN
MIRROR
PAPER TOWEL
DISPENSER,
MANUAL OR
TOUCHLESS
TOILET
TISSUE
DISP.
HAND DRYER
ALL MOUNTING HEIGHTS SHALL COMPLY WITH THE CURRENT A.D.A. STANDARDS AND THE ARCHITECTURAL ACCESS BOARD
1. HAND OPERATED FLUSH CONTROLS @44" A.F.F. (MAX.) TO BE ON THE WIDE SIDE OF TOILET AREA
2. TOE & KNEE SPACE SHALL COMPLY WITH A.D.A. - E.W.C. (4.15), LAVATORY (4.19)
3. SURFACE MOUNTED TOWEL DISPENSER AND SANITARY NAPKIN DISPENSER MAX. HEIGHT 53" A.F.F.
4. INSULATE HOT WATER PIPES AND DRAINS TO PROTECT AGAINST CONTACT - HANDISHIELD OR EQUAL. ALL NEW AND EXISTING SINK
LOCATIONS (AS REQUIRED).
NOTES:
1. 1/2" MAXIMUM TOTAL HEIGHT WITH 1/4" MAXIMUM VERTICAL
CHANGE AT EDGE.
2. 1 : 2 SLOPED BEVEL REQUIRED IF LEVEL CHANGE IS OVER
1/4" VERTICAL LEVEL CHANGE.
3. 1/4" MAXIMUM VERTICAL LEVEL CHANGE.
WHEELCHAIR ACCESS CLEAR SPACE @
LAVATORIES
CLEAR SPACE @ WATER
CLOSET FRONT ACCESS
CLEAR SPACE @
WATER CLOSET
CLEAR SPACE @ WATER
CLOSET SIDE ACCESS
ADA WASHROOM FIXTURE - MOUNTING HEIGHTS GENERAL NOTES:
HANDICAP
LAVATORY
1' -3
2'
-6 " M
IN
IM
U M
1'-5"MIN.
1' -3
4'-0" MINIMUM6"
4' -0
1' -3
2' -6
"M
IN
IM
U
M
1' -3
4'-8"
5' -0
1' -3
2' -6
"M
IN
IM
U
M
1' -3
4'-8"
4' -0
1' -3
2' -6
"M
IN
IM
U
M
5'-6"
1' -3
"�5'- 0"
MINIM
UM
WHEELC
HAIR
TURNIN
G SPACE
18" MIN
" M
IN 48
" M
IN
" M
IN
12" MIN
36" MIN
" M
IN
42" MIN
" M
IN
22" MIN 42
" M
IN
22" MIN
" M
IN
24" MIN
" M
IN
24" MIN
" M
IN
" M
IN
24" MIN
" M
IN
24" MIN
48" MIN
48" MIN
48" MIN
10" MAX.
" M
AX
24" MAX.
" M
AX
" M
AX
M
IN
20"-25"20" MAX.
" M
AX
" M
AX
" M
AX
1'-6"
3'-0"6"
2' -1
0" 1'
-7 " 48
" A .F
.F
(M
AX
"(M
AX
1' -6
2' -5
M
IN
2' -1
0" (M
AX
3' -4
M
AX
6"
9"
" A
.F .F
" A
.F .F
(M
AX
" M
IN
12" MAX
" M
IN
36" MIN CLEAR
4" 12"
1/ 2"
M
AX
P
IL
E H
EI
G
H T
1/ 4"
M
AX
1/ 2"
M
AX
1/ 4"
1/ 4"
-1 /2
1/
4" M
AX
FRONT APPROACH
PULL SIDE
FRONT APPROACH
PUSH SIDE
FRONT APPROACH PUSH
SIDE DOOR PROVIDED
WITH BOTH CLOSER AND
LATCH
HINGE APPROACH
FULL SIDE
HINGE APPROACH
PUSH SIDE
HINGE APPROACH PUSH
SIDE DOOR WITH
CLOSER AND LATCH
LATCH APPROACH
PULL SIDE
LATCH APPROACH
PULL SIDE
DOOR WITH CLOSER
LATCH APPROACH
PUSH SIDE DOOR
WITH CLOSER
DOORS IN
SERIES
LATCH APPROACH
PUSH SIDE
DOORS IN SERIES
DOORS IN SERIESHINGE APPROACH
PULL SIDE
(b)(a) (b)(a)
OBSTRUCTED HIGH
FORWARD REACH
OBSTRUCTED HIGH
FORWARD REACH
UNOBSTRUCTED
FORWARD REACH
OBSTRUCTED HIGH
SIDE REACH
OBSTRUCTED HIGH
SIDE REACH
UNOBSTRUCTED
HIGH SIDE REACH
BLUE BACKGROUND W/
WHITE TEXT AND SYMBOLS
NOTE: DO NOT PLACE ON DOORS.
PROTRUDING HAZARD
DOOR APPROACHES
REACH RANGES
RESTROOMS
PROTRUDING HAZARD INTERIOR ACCESS ROUTE IMPEDIMENTS
LEVEL CHANGES
A-101 DETAIL NUMBER
SHEET WHERE DRAWN
DETAIL REFERENCE
SIM
A
NEW GRID
IDENTIFICATION
LAYOUT GRID LINES
A102
ELEVATION NUMBER AND
DIRECTION OF VIEW
SHEET WHERE DRAWN
INTERIOR ELEVATION REFERENCE
101 ROOM NUMBER
ROOM NAME
ROOM TAG
ROOM NUMBER
ROOM FINISH
BASE FINISH
WALL FINISH
ROOM NAME
FINISH PLAN ROOM TAG
SECTION NUMBER
SHEET WHERE DRAWN
DIRECTION OF VIEW
A-101
SIM
SECTION
A-101
SIM
ELEVATION NUMBER
AND DIRECTION
SHEET WHERE DRAWN
SECTION DETAIL REFERENCE
PARTITION TYPE IDENTIFICATION MARK
A
EXISTING GRID
IDENTIFICATION
ELEVATION NUMBER
DIRECTION OF VIEW1
A-101
SIM
EXTERIOR ELEVATION
SHEET WHERE DRAWN
SCALE: 1/8" = 1'-0"
BASIC DRAWING
TITLE
DRAWING TITLE SYMBOLS
VIEW NAME
INDICATES HEIGHT
ABOVE PROJECT DATUM
+10'-0"
SECOND LEVEL
NAME OF LEVEL
LEVEL LINE
SEE CORRESPONDING
NUMBERED KEY NOTE ON SHEET
WHERE REFERENCE OCCURS
KEYED NOTE MARKED
REVISION NUMBER - SEE
REVISION HISTORY ON THE TITLE
BLOCK OF EACH SHEET
EXTENT OF CURRENT
REVISION
REVISION NUMBER AND EXTENT
CEILING TYPE TAG
CEILING TYPE TAG WITH
CEILING HEIGHT. HEIGHT
INDICATED IS AFF
2'X2' RECESSED LIGHT
FIXTURE
2'X4' RECESSED
LIGHT FIXTURE
FIRE PROTECTION-
SPRINKLER HEAD
F FIRE PROTECTION-
FIRE ALARM DEVICE
GYPSUM BOARD
CEILING OR SOFFIT
GWB
APC CEILING - 2X2 OR 2X4
AS INDICATED ON CEILING PLAN
ACT- ACOUSTICAL
CEILING TILES
COVE LIGHT (NOT ALL
INDICATED)
RECESSED LINEAR
LIGHT FIXTURE
PENDANT/SUSPENDED
LIGHT FIXTURE
PENDANT/SUSPENDED
LIGHT FIXTURE
EXIT SIGN,
SINGLE-SIDED EXIT SIGN,
DOUBLE-SIDED
HVAC SUPPLY
GRILLE
HVAC RETURN
GRILLE
HVAC SWITCHED
EXHAUST GRILLE
HVAC SUPPLY/RETURN
LINEAR DIFFUSER
ACCESS PANEL
ARCHITECTURAL REFERENCE SYMBOLS REFLECTED CEILING PLAN SYMBOLS
FLOOR PLAN SYMBOLS ARCHITECTURAL MATERIAL INDICATIONS
EARTH RIGID INSULATION
STEEL
PLYWOOD
GYPSUM WALL BOARD
ASPHALT
SAND
GROUT
DIMENSIONAL LUMBER
CONTINUOUS WOOD
FRAMING
DIMENSIONAL LUMBER
WOOD BLOCKING
CONCRETE MASONRY
UNIT
PRECAST CONCRETE
BRICK
CONCRETE
ALUMINUM
FINISH LUMBER
GRAVEL
GRANULAR DRAINAGE
MATERIAL
STONE
BATT INSULATION
DOOR OPENING
OVERHEAD
ROLLING DOOR
INTERIOR GLAZED
WINDOW
WINDOW TYPE
EQUIPMENT TYPE#i
DIMENSION SYMBOL
BASE CABINETS
BASE AND WALL
CABINETS
WALL CABINETS
TOILET PARTITION
AND DOOR
HANDRAIL
BUMPER GUARD
CORNER GUARD
CGCG
OVERHEAD ITEMS
UNDER-COUNTER ITEMS
NOT-IN-CONTRACT ITEMSNIC
FEC
FIRE EXTINGUISHER
CABINET
FE
FIRE EXTINGUISHER
(MOUNT 3'-6" AFF)
URINAL
LAVATORY -
COUNTERTOP
LAVATORY -
PEDESTAL/WALL HUNG
UTILITY SINK
FLOOR FINISH
TRANSITION SYMBOL
XXX-X
XXX-X
JANITOR'S
RECEPTOR
SHOWER
FLOOR DRAIN IN
SLOPING FLOOR
FD
FLOOR JUNCTION
BOX
ROOF SAFETY TIE-
BACK
ROOF DRAIN
RD
OVER FLOW ROOF
DRAIN
ORD
DOOR OPENING MARK
XX
X
SINGLE OPENING DOOR
DOUBLE ACTING DOOR
XX
X
XX
X
PAIR DOORS -
EQUAL SIZES
XX
X
PAIR DOORS -
UNEQUAL SIZES
XX
X
PAIR DOORS -
DOUBLE EGRESS
XXX
SLIDING DOOR -
BETWEEN JAMBS
DOOR WITH SIDE LIGHT
XX
X
PAIR - BI FOLD DOOR
XXX
@ AT
A AIR
AB AIR BARRIER
AB ANCHOR BOLT
AC AIR CONDITIONING
ACC ACCESSIBLE
ADD ADDENDUM
ADDL ADDITIONAL
ADJ ADJACENT
ADMIN ADMINISTRATIVE
AESS ARCHITECTURAL EXPOSED
STRUCTURAL STEEL
AFF ABOVE FINISHED FLOOR
AGGR AGGREGATE
AHJ AUTHORITIES HAVING JURISDICTION
AHU AIR HANDLING UNIT
AIC AMP INTERRUPTING CAPACITY
ALT ALTERNATE
ALUM ALUMINUM
AMP AMPERE
AMPC ACOUSTICAL METAL PAN CEILING
AOR AREA OF REFUGE
AP ACCESS PANEL
APC ACOUSTICAL PANEL CEILING
APPROX APPROXIMATE
AR ARGON
ARCH ARCHITECTURAL/ARCHITECT
PCC PRECAST CONCRETE
ASPH ASPHALT
ASSY ASSEMBLY
AT AIR TERMINAL DEVICE
AUTO AUTOMATIC
AV AUDIO VISUAL
AVE AVENUE
AVG AVERAGE
AVTR ACID VENT THROUGH ROOF
AW ACID WASTE
AWC ACOUSTIC WOOD CEILING
AWP ACOUSTICAL WALL PANEL
BD BOARD
BITUM BITUMINOUS
BL BORROWED LIGHT
BLDG BUILDING
BLKG BLOCKING/BLOCK
BLKT BLANKET
BM BENCH MARK
BOD BASIS OF DESIGN
BOS BOTTOM OF STEEL
BPL BASE PLATE
BRG BEARING
BRK BRICK
BSL BIO SAFETY LEVEL
BSMT BASEMENT
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
BTWN BETWEEN
BUR BUILT-UP ROOFING
C CHANNEL
C/C CENTER TO ROOFING
CAB CABINET
CAP CAPACITY
CB CATCH BASIN
CC CUBICAL CURTAIN
CFCI CONTRACTOR FURNISHED CONTRACTOR
INSTALLED
CFMF COLD FORM METAL FRAMING
CFOI CONTRACTOR FURNISHED OWNER
INSTALLED
CH BD CHALKBOARD
CHWS/R CHILLED WATER SUPPLY/RETURN
CG CORNER GAURD
CIP CAST IN PLACE CONCRETE
CIRC CIRCULATE/CIRCULATING
CJ CONTROL JOINT
CK CORK FLOORING
CL CENTERLINE
CLG CEILING
CLO CLOSET
CLR CLEAR
CM CONSTRUCTION MANAGER
CMU CONCRETE MASONRY UNIT
CO CARBON MONOXIDE
CO CLEANOUT
CO2 CARBON DIOXIDE
COL COLUMN
COMB COMBINATION/COMBINED
COMP COMPOSITE
CONC CONCRETE
COND CONDENSATE
CONF CONFERENCE
CONN CONNECTION/CONNECT
CONSTR CONSTRUCTION
CONT CONTINUOUS/CONNECT
CONTR CONTRACT(OR)
CONV CONVECTOR
COR CONTRACT OFFICER REPRESENTATIVE
CORP CORRIDOR
CP CONTROL PANEL
CPT CARPET
CR CARD READER
CS CUP SINK
CSK COUNTERSINK
CT CERAMIC TILE
CTR CENTER
CU CUBIC
CU FT CUBIC FEET
CU FT CUBIC FEET
CU YD CUBIC YARD(S)
CUH CABINET UNIT HEATER
CW COLD WATER
CW CURTAIN WALL
D DEPTH
DBL DOUBLE
DEPT DEPARTMENT
DH DOUBLE HUNG
DIA DIAMETER
DIAG DIAGONAL
DIFF DIFFERENCE
DIFF DIFFUSER
DIM DIMENSION
DIR DIRECTION
DISP DISPENSER
DISTR PNL DISTRIBUTION PANEL
DIV DIVISION
DL DEAD LOAD
DL DIVIDED LITES
DN DOWN
DO DOOR OPERATOR
DPTN DEMOUNTABLE PARTITION
DR DOOR
DS DOWNSPOUT
DTL DETAIL
DW DISHWASHER
DWG DRAWING
DWR DRAWER
DWTR DUMBWAITER
ARCHITECTURAL ABBREVIATIONS
E EAST
EA EACH
EC ELECTRICAL CONTRACTOR
ED EMERGENCY DEPARTMENT
EEW EMERGENCY EYE WASH
EF EXHAUST FAN
EFG ENTRANCE FLOOR GRILL
EFM ENTRANCE FLOOR MAT
EH EXHAUST HOOD
EIFS EXTERIOR FINISH INSULATION SYSTEM
EL ELEVATION
ELEC ELECTRIC (ELECTRICAL)
ELEV ELEVATOR
EMBED EMBEDDED
EMER EMERGENCY
EMT ELECTRICAL METALLIC TUBING
ENCL ENCLOSURE
ENTR ENTRANCE
EP ELECTRICAL PANEL
EPO EMERGENCY POWER OUTLET
EPT EPOXY PAINT
EPX EPOXY
EQ EQUAL
EQUIP EQUIPMENT
ES EMERGENCY SHOWER
ESR ELASOMETRIC SHEET ROOFING
ETR EXISTING GTO REMAIN
EWC ELECTRIC WATER COOLER
EWS EMERGENCY SHOWER AND EYE WASH
EXC EXCAVATE(D)
EXH EXHAUST
EXIST EXISTING
EXP EXPOSED
EXT EXTERIOR
F FAHRENHEIT
FA FIRE ALARM
FB FLOOR BOX
FCU FAN COIL UNIT
FD FLOOR DRAIN
FDC FIRE DEPT CONNECTION
FDTN FOUNDATION
FDV FIRE DEPT VALVE
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISHED FLOOR
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FHR FIRE HOSE RACK
FIN FINISH (ED)
FIXT FIXTURE
FLEX FLEXIBLE
FLR FLOOR
FP FIRE PROTECTION
FPM FEET PER MINUTE
FPS FEET PER SECOND
FR FIRE RETARDANT/RESISTANT
FRP FIBERGLASS REINFORCED
PANEL/POLYESTER/PLASTIC
FRT FIRE RESISTANT TREATED
FRZ FREEZER
FT FEET
FTG FOOTING
GA GAGE (GAUGE)
GAL GALLON(S)
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERAL
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GFRC GLASS FIBER REINFORMCENT
CONCRETE
GFRP GLASS FIBER REINFORCED PLASTER
GL GLASS
GPC GROUND POLISHED CONCRETE
GRT GROUT
GWB GYPSUM WALL BOARD
HB HOSE BIBB
HD HEAD
HD HUB DRAIN
HDWD HARDWOOD
HDWE HARDWARE
HE HELIUM
HEX HEXAGON
HM HOLLOW METAL
HO ELECTROMAGNETIC HOLD OPEN
HOLD HOLD DIMENSION
HORIZ HORIZONTAL
HP HIGH POINT
HP HORSEPOWER
HPC HIGH PERFORMANCE COATING
HR HOUR
HSKPG HOUSEKEEPING
HSS HOLLOW STRUCTURAL SHAPE
HT HEIGHT
HVAC HEATING, VENTILATING & AIR
CONDITIONING
HW HOT WATER
HWS HEAD WELDED STUD
HYD HYDROGEN
IB INTEGRAL BLINDS
ICRA INFECTION CONTROL RISK ASSESSMENT
ID INSIDE DIAMETER/DIMENSION
IMP INSULATED METAL PANEL
IN INCH(ES)
INCL INCLUDE
INFO INFORMATION
INSUL INSULATION/INSULATED
INT INTEGRAL
INV INVERT
INV EL INVERT ELEVATION
JAN JANITOR
JAN CLO JANITOR CLOSET
J-BOX JUNCTION BOX
JST JOIST
JT JOINT
K KIP (1000 LB)
KO KNEE SPACE OPENING
KPL KICK PLATE
KV KILOVOLT
KW KILOWATTS
KWH KILOWATT HOUR
L ANGLE
L LENGTH/LONG
LAB LABORATORY
LAN LOCAL AREA NETWORK
LAV LAVATORY
LBS POUND(S) / LBS
LEV LEVEL
LF LINEAR FOOT
LFG LAB FURNISHINGS CONTRACTOR
LH LEFT HAND
LINO LINOLEUM
LKR LOCKER
LL LIVE LOAD
LN2 LIQUID NITROGEN
LNDG LANDING
LOC LOCATION (LOCATE)
LONG LONGITUDINAL
LPT LOW POINT
LT GA LIGHT GAGE
LTG LIGHTING
LTG PNL LIGHTING PANEL
LVR LOUVER
LW LIGHTWEIGHT
M METER
MACH MACHINE
MAN MANUAL
MATL MATERIAL
MAX MAXIMUM
MB MARKER BOARD
MC MECHANICAL CONTRACTOR
MCC MOTOR CONTROL CENTER
MDO MEDIUM DENSITY OVERLAY
MECH MECHANICAL
MECH RM MECHANICAL EQUIPMENT ROOM
MED MEDICINE/MEDICAL
MED MEDIUM
MEMB MEMBRANE
MEP MECHANICAL, ELECTRICAL, PLUMBING
MEZZ MEZZANINE
MFR MANUFACTURER
MGR MANAGER
MH MANHOLE
MIC MOBILE INSTRUMENT CART
MICRO MICROWAVE
MIN MINIMUM
MIN MINUTE
MIR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING/MOULDING
mm MILLIMETER
MO MASONRY OPENING
MPH MILES PER HOUR
MTD MOUNTED
MTG MOUNTING
MTL METAL
N NORTH
N2 NITROGEN, PIPED GAS
NA NOT APPLICABLE
NG NATURAL GAS
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT IN SCALE
NW NORMAL WEIGHT
O OXYGEN, PIPED GAS
OA OUTSIDE AIR
OA OVERALL
OC ON CENTER
OCC OCCUPANCY/OCCUPATION/OCCUPY
OD DRAIN (OVERFLOW)
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED, CONTRACTOR
INSTALLED
OFF OFFICE/OFFICER
OFOI OWNER FURNISHED,OWNER INSTALLED
OH OPPOSITE
OHSC OVER HEAD SERVICE CARRIER
OPNG OPENING
OPP OPPOSITE
OR OPERATING ROOM
OSHA OCCUPATIONAL SAFETY AND HEALTH
ASSOCIATION
OZ OUNCE
PCC PRECAST CONCRETE - STRUCTURAL
PCF POUNDS PER CUBIC FOOT
PERF PERFORATED
PH PHASE
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLF POUNDS PER LINEAR FOOT
PLYWD PLYWOOD
PNL PANEL/PANELING
PR PAIR
PREFAB PREFABRICATED
PREFIN PREFINISHED
PREP PREPARATION
PS PROJECTION SCREEN
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT
P-TYPE PARTITION TYPE
PVC POLYVINYL CHLORIDE
PVMT PAVEMENT / PAVING
PW POLISHED WATER
QT QUARRY TILE
QTY QUANTITY
R RADIUS
R RISER
RA RETURN AIR
RB RESILIENT BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REC RECESSED
RECPT RECEPTACLE
REF REFERENCE
REF REFRIGERATOR
REINF REINFORCED/REINFORCEMENT
REQ REQUIRED
RET RETURN
REV REVISION
RF RESINOUS FLOORING
RH RELATIVE HUMIDITY
RH RIGHT HAND
RM ROOM
RO REVERSE OSMOSIS
RO ROUGH OPENING
RPM REVOLUTION PER MINUTE
RUB RUBBER FLOORING
RV ROOF VENT
S SOUTH
SA SUPPLY AIR
SAN SANITARY
SC SEALED CONCRETE
SCF STATIC CONTROL FLOORING
SCHED SCHEDULE
SECT SECTION
SF SQUARE FOOT
SGL SINGLE
SHT SHEET
SHT MTL SHEET METAL
SHWR SHOWER
SIM SIMILAR
SOG SLAB ON GRADE
SPEC SPECIFICATION
SPKR SPEAKER
SPP SOLID PHENOLIC PANELS
SQ IN SQUARE INCHES
SQ YD SQUARE YARD
SS STAINLESS STEEL
SSM SOLID SURFACE MATERIAL
ST STONE
ST STREET
STD STANDARD
STL STEEL
STOR STORAGE
STRUC STRUCTURAL /STRUCTURE
SUSP SUSPENDED
SV SHEET VINYL
SVT SOLID VINYL TILE
SW SWITCH
T TEMPERED
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TA TOILET ACCESSORIES
TB TACKBOARD
TBB TILE BACKER BOARD
TBD TO BE DETERMINED
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPERATURE/TEMPERED
THK THICK/THICKNESS
TLT TOILET
TO TOP OF
TPO THERMOPLASTIC OLEFIN
TR TELECOM ROOM
TRDT TREATED
TS TUBE STEEL
TSTAT THERMOSTAT
TV TELEVISION
TYP TYPICAL
TZ TERRAZZO
UC UNDER COUNTER
UL UNDERWRITERS LABORATORY
UNO UNLESS NOTED OTHERWISE
UPH UPHOLSTERY
UPS UNINTERRUPTED POWER SUPPLY
UTIL UTILITY
UV ULTRAVIOLET
VA VETERAN ADMINISTRATION
VAR VARIES
VAV VARIABLE AIR VOLUME
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VFD VARIABLE FREQUENCY DRIVE
VIF VERIFY IN FIELD
VOL VOLUME
VR VAPOR RETARDER
VTR VENT THRU ROOF
W WEST
W WIDTH
W/ WITH
W/O WITHOUT
WC WALL COVERING
WD WOOD
WF WIDE FLANGE STEEL BEAM
WP WALL PROTECTION
WP WORKING POINT
WT WINDOW TREATMENTS
WT WEIGHT
WTR WATER
WHEEL CHAIR
CLEARANCE
CENTERLINE
ø 5' - 0
#i CEILING TYPE
? KEYNOTE SYMBOL
### DOOR TYPE TAG
Ref
ELEVATION NUMBER
SYMBOL
EXIT SIGN SYMBOL
ACT-?
ACT-?
NORTH ARROW
SYMBOL
X WALL TAG SYMBOL
#t
Zone Name ZONE TAG SYMBOL
BREAK LINE SYMBOL
DEMO APC CEILING - 2X2 OR 2X4
AS INDICATED ON CEILING PLAN
ACT- ACOUSTICAL
CEILING TILES
ADA COMPLIANCE DETAILS
WOOD
SVT-1 SOLID VINYL TILE
LVT-1 LUXURY VINYL TILE
VCT-1 VINYL COMPOSITE TILE
WSF-1 WELDED SEAM FLOORING
RES-3 RESINOUS FLOORING
SC-1 SEALED CONCRETE
GLASS
T
T
1-HR FIRE/SMOKE
2-HR FIRE/SMOKE
(TRAVEL DISTANCE 300' OR
LESS)
- SMOKE BARRIER
2-HR FIRE
-STAIRS
-FLOOR TO FLOOR OPENINGS
-OCCUPANCY SEPARATION
????? SIGNAGE SYMBOL
3603 NW 98th Street, Suite B Gainesville, FL 32606 Phone: (352) 474-6124 Fax: (352) 553-4437
COA: FL #29758
AKEA Design Project No. AD213-23
Design, Inc.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE LAKE NONA
BUILDING 2 FOR CANTEEN
ORLANDO, FLORIDA
OF
ARCHITECT - OF - RECORD FL. REG. NO.
675-23-103
FINAL CONSTRUCTION
DRAWINGS
This item has been electronically signed and sealed by the individual named at right.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
8/
/2
1:
:4
PM
JRF SNG
JENNIFER R. FONG AR97191
AG-001
ARCHITECTURAL GENERAL NOTES,
ABBREVIATIONS AND SYMBOLS
5 69AUGUST 22, 2024
Revisions: Date:
Date: 2024.08.28 17:06:33-04'00'
UP
DN
F
G
H
J
K
L
2627282930313233
32.3
EXISTING FLOORING
TO REMAIN
N.I.C.
N.I.C.
N.I.C.
N.I.C.
DEDUCT
ALTERNATE #1
DEMOLITION KEYNOTES
GENERAL DEMOLITION
FLOOR PLAN NOTES
1. FIELD VERIFY ACTUAL CONDITIONS &
DIMENSIONS TO EXISTING ELEMENTS - NOTIFY
ARCHITECT AND VA COR OF DISCREPANCIES &
UNDOCUMENTED CONDITIONS THAT CONFLICT
WITH NEW WORK.
2. COORDINATE WITH VA COR FOR REMOVING
FURNITURE/ COUNTER(S) OR ANY MOVABLE
PART(S) IF NECESSARY AND STORE FOR
FUTURE USE.
3. REFER TO MECHANICAL, PLUMBING, AND
ELECTRICAL DRAWINGS FOR POWER,
LIGHTING, THE EXACT LOCATIONS OF FLOOR
DEMOLITION/PROPOSED DRAINS, IF
APPLICABLE.
4. REFER TO G-002 PHASING PLAN FOR
INSTRUCTION OF THE DEMOLITION SCOPE OF
WORK IN THIS PROJECT.
5. PATCH FINISHES & MATERIALS DISTURBED IN
DEMOLITION & IN THE EXECUTION OF NEW
WORK TO MATCH ADJACENT SURFACES.
6. REMOVE/ RELOCATE MOVEABLE EQUIPMENT
AS NECESSARY PER THE NEW EQUIPMENT
LAYOUT PER PHASING PLAN.
7. REFER TO C&T PLANS IN K SHEETS AND C&T
DOCUMENTS IN SPECIFICATIONS FOR
EQUIPMENT DEMOLITION AND EXISTING
EQUIPMENT TO PROTECT & REINSTALL.
8. REMOVE KITCHEN EQUIPMENT, PREPARATION
SINKS AND FURNITURE FOR FLOOR
INSTALLATION. TEMPORARILY CAP AND
PROTECT PLUMBING AND OTHER UTILITIES AS
NECESSARY. TEMPORARILY PROTECT AND
STORE DURING TEMPORARY REMOVAL FOR
REINSTALLATION IN ITS ORIGINAL LOCATION
AND RECONNECTING WITH THE EXISTING
UTILITIES.
SEE K SHEETS AND PLUMBING FOR SINK
REPLACEMENT INFORMATION.
REMOVE EXISTING WALL COVERING OF FOOD
MURAL IN SERVERY AREA. REPLACE PER
INTERIOR DESIGN SELECTION.
4 REMOVE, STORE, PROTECT, AND REINSTALL
EXISTING OFFICE WORKSTATIONS, STORAGE
EQUIPMENT IN THE CORRIDOR.
REMOVE, STORE, PROTECT, AND REINSTALL
EXISTING COUNTER ELECTRIC SODA FOUNTAIN
SYSTEM. REMOVE COUNTERTOP AND
BACKSPLASH. EXISTING CASEWORK TO REMAIN.
REMOVE EXISTING FLOOR FINISH AND WALL
GUARDS AS APPLICABLE. PROTECT FLOOR
DRAINS DURING CONSTRUCTION.
DEMOLISH EXISTING WALL AND WALL GUARDS.
DEMOLISH EXISTING HOLLOW METAL WINDOWS
AND FRAMES.
DEMOLISH EXISTING DOOR AND HARDWARE.
RETURN ALL HARDWARE TO VA FOR PROCESSING.
NOT IN CONTRACT
LEGEND
DEMOLISH EXISTING CONCRETE CURB. REPAIR TO
RECEIVE NEW FINISHES.
DEMOLISH TRAY RETURN EQUIPMENT, WALL
ABOVE TO SOFFIT, SIGNAGE. PATCH AND REPAIR
TO RECEIVE NEW ENCLOSURE REFER TO MEP
FOR ADDITIONAL DEMOLITION SCOPE.
REMOVE CEILING TILES AS NEEDED.
REMOVE EXISTING PREPARATION SINKS AND
RETURN TO OWNER.
15 DEMOLISH FOOD WASTE PULPER SYSTEM WITH
CONTROL PANEL.
16 EXISTING HOODS TO REMAIN IN PLACE DURING
RENOVATION. ICRA BARRIERS TO BE
COORDINATED AND APPROVED BY VA.
17 DEMOLISH WATER PRESSURE HOSE BIB. REFER
TO MEP FOR DEMOLITION SCOPE.
18 REMOVE EXISTING SAFEGUARD POWER WASHER.
PREPARE FOR REINSTALLATION ONCE WALL IS
REBUILT.
MOLD REMEDIATION FOCUS PER VA. REFER TO
CIH REPORT IN SPECIFICATIONS FOR MORE
DETAILS.
19 REMOVE EXISTING DRAIN FOR REUSE. REFER TO
PLUMBING FOR ADDITIONAL DETAILS.
20 REFINISH WITH STAINLESS STEEL.
21 REMOVE EXISTING CARD READER. REFER TO
ELECTRICAL FOR MORE INFORMATION.
REFER TO MEP DRAWING FOR
ADDITIONAL INFORMATION.
DEMOLISH CEILING TILES, GRID, AND
APPURTENANCES. REFER TO MEP/FP FOR
ADDITIONAL INFORMATION.
REMOVE EXISTING STAINLESS STEEL WALL PANEL
& CART BUMPER RAIL. REMOVE EXISTING GWB TO
CEILING ON ROOM 1P601a SIDE ONLY.
SLAB DEMOLITION PER 2/ AE-502. COORDINATE
WITH PLUMBING FOR LOCATION. 23
SLAB CHANGES PER 1/ AE-502. COORDINATE WITH
PLUMBING AND 2/ AE402 FOR SIZE AND LOCATION.
1U701b
OFFICE;
SUPERVISOR
1U701
CASHIER
1U701c
OFFICE; LOANS
1G304
RETAIL STORAGE
1N601
CANTEEN RETAIL
1P106
CHIEF CANTEEN
1P105
NUTRITION
THERAPY
1P107
CHIEF FNS
1P103
PROGRAM
MANAGER
1PC01a
SECRETARY/WAIT
1PC01b DIET TECHS 1PC01c
COORDINATION
CENTER
1N602
ADMIN CLERKS
1U702c
TRAVEL CLERK
1U702
TRAVEL CLERK
1U702b
AGENT CASHIER
1U702a
AGENT CASHIER
1U301
COMM
1N601b
COMM
1N601a
ELEC 1V705
COMM
1V703
ELEC
1V112b
COMM
1V112a
ELEC
1V811
ELEC
1U501c
HAC
1U501
PHARMACY
1U502a
WAITING
1U501a
CONSULT
1N403
OFFICE (DAV)
1N405
OFFICE
1N406
OFFICE (PVA)
1N203
OFFICE
(FDVA/STATE)1N204
OFFICE
(FDVA/STATE)
1N206
OFFICE
(FDVA/STATE)
1N404
OFFICE (PVA)
1V803
BULK
REFRIGERATED
STORAGE
1V805a
VENDING COOLER
1V805
VENDING STORAGE
1V712
RECEIVING
1P601
DISHWASH
1V721
EXTRACTOR
1V802
BULK CARTS
STAGING
1V708
RETHERM
1V704
MEAL
CARTS/REFRIGERATOR
1V702
TRAY ASSEMBLY
1V101c
BLAST CHILLER
1V101b
POT/PAN WASH
1V701
TRAY CART
1V101
FOOD PRODUCTION
1V101a
DAY COOLER
1N606
MONEY ROOM
1N608
ASST CHIEF (FOOD)
1V812
NON-FOOD
STORAGE
1V112
DRY STORAGE
1V110
INGREDIENT ROOM
1G304a
HAC
1V104a
WAREWASH
1UC02
CORRIDOR
1V105
FREEZER
1V103
REFRIGERATED
STORAGE
1U701a
VAULT
1V809
ELEC
1M811
CONCESSIONS
1P606
CLEANING EQUIP
1P602
SANITARY SUPPLY
1V104
SERVERY
1U302
HAC
1U501b
O.P. SECURE
PRESCRIPTION
STORAGE
1N607
TOILET
1U502
PICK-UP WINDOW
1V712a
RECEIVING OFFICE
1NC06
CORRIDOR
1G302a
LOCKERS MALE
1UC02
CORRIDOR
1PC02
CORRIDOR
1VC07
AISLE
1VC08
AISLE
1N605
TOILET
1V106
DETERGENT RM
1V102
SODA CLOSET
1V104b
PIZZA OVEN
1P601a
CART/CAN WASH
1PC06a
ELEV LOBBY
1V806
REFRIGERATION
1N205
OFFICE
(FAVA/STATE)
1UC05
AISLE
1V811a
ELEC
1UC07
AISLE
1PC01
AISLE
1PC06
CORRIDOR
1NC02
PASSAGE
1NC04
CORRIDOR
1US01
STAIR - PHARMACY
1VS01
STAIR
1PS01
STAIR
1PE01
ELEVATOR
1PE02
ELEVATOR
1U701d
ATM WORKROOM
1G304b
VESTIBULE
1P601c
SANITARY SUPPLY
1V104
SERVERY
1P608
HAC
1UC03
PASSAGE
1U303
ELEC
3603 NW 98th Street, Suite B Gainesville, FL 32606 Phone: (352) 474-6124 Fax: (352) 553-4437
COA: FL #29758
AKEA Design Project No. AD213-23
Design, Inc.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE LAKE NONA
BUILDING 2 FOR CANTEEN
ORLANDO, FLORIDA
OF
ARCHITECT - OF - RECORD FL. REG. NO.
675-23-103
FINAL CONSTRUCTION
DRAWINGS
This item has been electronically signed and sealed by the individual named at right.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
8/
/2
1:
:5
PM
JRF SNG
JENNIFER R. FONG AR97191
AD-101
LEVEL 1, AREA D3 - DEMOLITION 1ST FLOOR
PLAN
6 69AUGUST 22, 2024
SCALE: 1/8" = 1'-0"1 LEVEL 1, AREA D3 - DEMOLITION 1ST FLOOR PLAN E1 E2 E3
E4
C1
A3 A2
A1 B1
B2
CLINIC
HOSPITAL
D1 D2 D3
D4 D5 D6
P-W P-E
A4
W
KEY PLAN
NTS
W
Revisions: Date:
Date: 2024.08.28 17:13:20-04'00'
UP
DN
C
F
G
H
J
K
L
2627282930313233
32.3
N.I.C.
AE-301
AE-402
1V101
FOOD PRODUCTION
1V101b
POT/PAN WASH
1VC07
AISLE
1V702
TRAY ASSEMBLY
1V704
MEAL
CARTS/REFRIGERATOR
1V708
RETHERM
1V802
BULK CARTS
STAGING
1V806
REFRIGERATION/
COMPRESSOR
ROOM
1V101c
BLAST CHILLER
1V103
REFRIGERATED
STORAGE
1V105
FREEZER
1V110
INGREDIENT ROOM1V106
DETERGENT RM
1U302
HAC 1UC03
PASSAGE
1U301
COMM
1U303
ELEC
1V102
SODA CLOSET
1NC06
CORRIDOR
1N606
MONEY ROOM
1N608
ASST CHIEF (FOOD)
1N607
TOILET
1N605
TOILET
1V101a
DAY COOLER
1P601a
CART/CAN WASH
1P601
DISHWASH
1V721
EXTRACTOR
1V703
ELEC
1V705
COMM
1P608
HAC
1PC01
AISLE
1P103
PROGRAM
MANAGER
1P105
NUTRITION
THERAPY
1P107
CHIEF FNS
1P606
CLEANING EQUIP
1PC06
CORRIDOR
1PC06a
ELEV LOBBY
1V811
ELEC
1V811a
ELEC
1V809
ELEC
1VC08
AISLE
1V812
NON-FOOD
STORAGE
1V112
DRY STORAGE
1V112a
ELEC
1V112b
COMM
1V104b
PIZZA OVEN
1V805
VENDING STORAGE
1V805a
VENDING COOLER
1V803
BULK
REFRIGERATED
STORAGE
AE-401
1N601
CANTEEN RETAIL
1N601a
ELEC
1N601b
COMM
1N405
OFFICE
1N404
OFFICE (PVA)
1NC04
CORRIDOR
1N406
OFFICE (PVA)
1N205
OFFICE
(FAVA/STATE)
1N203
OFFICE
(FDVA/STATE)
1NC02
PASSAGE
1G302a
LOCKERS MALE
1G302b
TLT & SHWR MALE
1PC02
CORRIDOR
1PC01a
TRAINING AREA
1G304
RETAIL STORAGE
1G304b
VESTIBULE
1G304a
HAC
1PE02
ELEVATOR
1PE01
ELEVATOR
1U702c
TRAVEL CLERK
1U702b
AGENT CASHIER
1U702a
AGENT CASHIER
1U702
TRAVEL CLERK
1UC05
AISLE
1UC07
AISLE
1U701c
OFFICE; LOANS
1N602
ADMIN CLERKS
1U701b
OFFICE;
SUPERVISOR
1U701
CASHIER
1U701a
VAULT
1M811
CONCESSIONS
1N403
OFFICE (DAV)
1U501
PHARMACY
1U502
PICK-UP WINDOW
1U501a
CONSULT
1US01
STAIR - PHARMACY
1U501c
HAC
1U501b
O.P. SECURE
PRESCRIPTION
STORAGE
1V112
DRY STORAGE
1VS01
STAIR
1P111
DIET TECH
1P108
INTERNSHIP
1P109
DIET TECH/ INTERN
DIRECTOR
1P110
ASSIST. CHIEF
1V104
SERVERY
N.I.C.
N.I.C.
N.I.C.
1P104
STORAGE
N.I.C.
AE-702
AE-702
1V104a
OPEN OFFICE
A3A
A3D
A3D
1P110 A3D
1P111
A3D
B23
1P1081P109
A3D
A3D
A3A
1P C
B22 B22
B22B22
B22B22
C2C
C2C
C2C
C2C
1V712a
RECEIVING OFFICE
1V104
SERVERY
AE-702
1P106
CHIEF CANTEEN
1P601c
SANITARY SUPPLY
1P602
SANITARY SUPPLY
10' - 0" 22' - 6"
10' - 0" 25' - 5" 4' - 5"
6'
0"
A3D
C3A
1V712
RECEIVING
CR
EX
IS
T.
C
R
C2CC2C
CR
AE-501 4
AE-501
AE-501
AE-501
DEDUCT
ALTERNATE #1
AE-501
AE-501
AE-501
0"
1'
2' - 6"
KITCHEN FLOORING PER AF-121.
REPLACE COUNTER TOP TO MATCH EXISTING MATERIAL AND
FINISHES. REFER TO DETAILS AND ELEVATIONS.
REPLACE TRAY LINE. REFER TO C&T DESIGN EQUIPMENT CO.
INC PLAN FOR LOCATION AND CONFIGURATION.
REPLACE FOOD MURAL IN WALL COVERING. COORDINATE
WITH INTERIOR DESIGN FOR SPECIFIC SELECTION.
REPLACE DISHWASH EQUIPMENT PER C&T DOCUMENTS.
PROPOSED FLOOR PLAN NOTES
1. REFER TO C&T PLANS IN K SHEETS AND C&T
DOCUMENTS IN SPECIFICATIONS FOR MORE
INFORMATION FOR EXACT LOCATIONS AND
CONFIGURATIONS FOR THE NEW EQUIPMENT.
2. REFER TO TEMPORARY LAYOUT FOR THE PROPOSED
OFFICE LOCATION ON SHEET G-003.
3. REFER TO MEP DRAWINGS FOR MORE INFORMATION.
4. REFER TO ENLARGED LAYOUTS FOR MORE DETAILS IN
REGARD FURNITURE AND EQUIPMENT.
5. REFER TO SPECIFICATIONS FOR WALL PROTECTION
INFORMATION.
6. REFER TO AE-502 FOR SLAB AND INTERSTITIAL FLOOR
DETAILS.
KEYNOTES NOTES
NOT IN CONTRACT
SCOPE LEGEND
PLACEMENT OF CARD READER (CR) LOCATION.
HAND SINKS. COORDINATE WITH K SHEETS AND
MECHANICAL/ PLUMBING FOR ADDITIONAL
INFORMATION.
REINSTALL COMMERCIAL SINKS.
PLACE OFFICE TEMPORARY WALL, DOOR, AND
OFFICE FURNITURES/ EQUIPMENT IN THE RETHERM
DURING CONSTRUCTION PHASING PERIOD FOR
TEMPORARY PLACEMENT.
WALL PROTECTION OVER EXISTING WALL.
REINSTALL EXISTING EQUIPMENT/ PLUMBING
FIXTURES AFTER FOR FLOOR FINISH PLACEMENT.
COORDINATE WITH MECHANICAL AND ELECTRICAL
FOR ADDITIONAL DETAILS.
FURRED WALL PLACEMENT WITH HAND SINK AND
EYEWASH STATION.
FINISHES TO MATCH ADJACENT EXISTING EACH SIDE.
EDGE OF EXISTING WALL TO REMAIN.
PLACE CORNER GUARD.
SEE ELECTRICAL FOR UNISTRUT INSTUCTIONS.16
CANTEEN
3603 NW 98th Street, Suite B Gainesville, FL 32606 Phone: (352) 474-6124 Fax: (352) 553-4437
COA: FL #29758
AKEA Design Project No. AD213-23
Design, Inc.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE LAKE NONA
BUILDING 2 FOR CANTEEN
ORLANDO, FLORIDA
OF
ARCHITECT - OF - RECORD FL. REG. NO.
675-23-103
FINAL CONSTRUCTION
DRAWINGS
This item has been electronically signed and sealed by the individual named at right.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
8/
/2
1:
:1
PM
JRF SNG
JENNIFER R. FONG AR97191
AE-101
LEVEL 1, AREA D3 - 1ST FLOOR PLAN
7 69AUGUST 22, 2024
SCALE: 1/8" = 1'-0"1 LEVEL 1, AREA D3 - 1ST FLOOR PLAN
ROOM # ROOM NAME AREA
1VC07 AISLE 1237 SF
1PC01 AISLE 260 SF
1VC08 AISLE 915 SF
1P110 ASSIST. CHIEF 114 SF
1V101c BLAST CHILLER 44 SF
1V802 BULK CARTS STAGING 395 SF
1V803 BULK REFRIGERATED
STORAGE
658 SF
1P601a CART/CAN WASH 319 SF
1P106 CHIEF CANTEEN 160 SF
1PC02 CORRIDOR 181 SF
1PC06 CORRIDOR 229 SF
1V101a DAY COOLER 176 SF
1P111 DIET TECH 263 SF
1P109 DIET TECH/ INTERN
DIRECTOR
117 SF
1P601 DISHWASH 596 SF
1PC06a ELEV LOBBY 489 SF
1V721 EXTRACTOR 108 SF
1V101 FOOD PRODUCTION 3801 SF
1V105 FREEZER 573 SF
1P108 INTERNSHIP 313 SF
1V704 MEAL
CARTS/REFRIGERATOR
722 SF
1V104a OPEN OFFICE 731 SF 1V101b POT/PAN WASH 293 SF
1V712 RECEIVING 170 SF
1V103 REFRIGERATED STORAGE 814 SF
1V806 REFRIGERATION 278 SF
1V708 RETHERM 749 SF
1P601c SANITARY SUPPLY 77 SF
1V104 SERVERY 4144 SF
1P104 STORAGE 24 SF
1PC01a TRAINING AREA 170 SF
1V702 TRAY ASSEMBLY 417 SF
1V805a VENDING COOLER 115 SF
1V805 VENDING STORAGE 176 SF
E1 E2 E3
E4
C1
A3 A2
A1 B1
B2
CLINIC
HOSPITAL
D1 D2 D3
D4 D5 D6
P-W P-E
A4
W
KEY PLAN
NTS
W
Revisions: Date:
Date: 2024.08.28 17:22:52-04'00'
UP
DN
C
1P108
1P111
1P109
1P110
1P
F
G
H
J
K
L
2627282930313233
32.3
1V112b
COMM
1V112a
ELEC
INGREDIENT ROOM
1V110
RES 6A
RES 6A
1V811
ELEC
1V811a
ELEC
1V809
ELEC
SODA CLOSET
1V102
RES 6A
RES 6A
1N601
CANTEEN RETAIL
1U301
COMM 1U303
ELEC
1UC03
PASSAGE
1U302
HAC
1U501b
O.P. SECURE
PRESCRIPTION
STORAGE
1U501
PHARMACY
1U502
PICK-UP WINDOW
1N606
MONEY ROOM
1U702b
AGENT CASHIER
1U702a
AGENT CASHIER
1U702
TRAVEL CLERK
1U702c
TRAVEL CLERK
1U701c
OFFICE; LOANS
1N605
TOILET
1N607
TOILET
1N608
ASST CHIEF (FOOD)
1U701b
OFFICE;
SUPERVISOR
1U701a
VAULT
1U701
CASHIER
1UC07
AISLE
1N602
ADMIN CLERKS
1M811
CONCESSIONS
1N405
OFFICE
1N403
OFFICE (DAV)
1N404
OFFICE (PVA)
1N203
OFFICE
(FDVA/STATE)
1N205
OFFICE
(FAVA/STATE)
1N406
OFFICE (PVA)
1G302b
TLT & SHWR MALE
1G302a
LOCKERS MALE
1G304
RETAIL STORAGE
1G304b
VESTIBULE
1G304a
HAC
1N601b
COMM
1N601a
ELEC
1PE02
ELEVATOR
1PE01
ELEVATOR
1PS01
STAIR
CLEANING EQUIP
1P606
RES 6A
RES 6A
1P608
HAC
1P107
CHIEF FNS
1P105
NUTRITION
THERAPY
1P103
PROGRAM
MANAGER
1V705
COMM
1V703
ELEC
NON-FOOD STORAGE
1V812
RES 6A
RES 6A
1VS01
STAIR
PIZZA OVEN
1V104b
RES 6A
RES 6A
1U501a
CONSULT
1UC05
AISLE
1US01
STAIR - PHARMACY
1U501c
HAC
DETERGENT RM
1V106
RES 6A
RES 6A
1U501.2
1U701.1
1U701.2
1U501.1
DRY STORAGE
1V112
RES 6A
RES 6A
INTERNSHIP
1P108
LVT
RB
P-1
ACT-1
DIET TECH/ INTERN
DIRECTOR
1P109
LVT
RB
P-1
ACT-1
ASSIST. CHIEF
1P110
LVT
RB
P-1
ACT-1
1P106
CHIEF CANTEEN
AISLE
1PC01
LVT
RB
P-1
ACT-1
DIET TECH
1P111
LVT
RB
P-1
ACT-1
FOOD PRODUCTION
1V101
RES 6A
RES 6A
TRAY ASSEMBLY
1V702
RES 6A
RES 6A
MEAL
CARTS/REFRIGERATOR
1V704
RES 6A
RES 6A
BULK CARTS STAGING
1V802
RES 6A
RES 6A
REFRIGERATION/
COMPRESSOR ROOM
1V806
RES 6A
RES 6A
REFRIGERATED STORAGE
1V103
RES 6A
RES 6A
FREEZER
1V105
RES 6A
RES 6A
BULK REFRIGERATED
STORAGE
1V803
RES 6A
RES 6A
CART/CAN WASH
1P601a
RES 6A
RES 6A
SSP
ACT-2
ELEV LOBBY
1PC06a
RES 6A
RES 6A
RECEIVING
1V712
RES 6A
RES 6A
RECEIVING OFFICE
1V712a
RES 6A
RES 6A
VENDING STORAGE
1V805
RES 6A
RES 6A
VENDING COOLER
1V805a
RES 6A
RES 6A
EXTRACTOR
1V721
RES 6A
RES 6A
DISHWASH
1P601
RES 6A
RES 6A
SSP
ACT-2
SERVERY
1V104
RES 6A
RES 6A
AISLE
1VC08
RES 6A
RES 6A
BLAST CHILLER
1V101c
RES 6A
RES 6A
POT/PAN WASH
1V101b
RES 6A
RES 6A
DAY COOLER
1V101a
RES 6A
RES 6A
N.I.C.
N.I.C.
N.I.C.
N.I.C.
N.I.C.
(TYP.)
TRAINING AREA
1PC01a
LVT
RB
P-1
ACT-1
STORAGE
1P104
LVT
LVT
P-1
ACT-1
SANITARY SUPPLY
1P602
RES 6A
RES 6A
CORRIDOR
1PC06
RES 6A
RES 6A
AISLE
1VC07
RES 6A
RES 6A
RETHERM
1V708
RES 6A
RES 6A
OPEN OFFICE
1V104a
LVT
RB
P-1
ACT-1
SERVERY
1V104
RES 6A
RES 6A
SANITARY SUPPLY
1P601c
RES 6A
RES 6A
ACT-1
CORRIDOR
1PC02
RES
RB
CT
FEC
EX
IS
T.
FE
C
EXIST.
FEC
EX
IS
T.
FE
C
FEC
EXIST.
FEC
EXIST.
FEC
EDGE OF SSP
DEDUCT
ALTERNATE #1
1. MATCH, PATCH, AND EXTEND WALL, FLOOR, BASE, AND
CEILING FINISHES TO PROVIDE INCONSPICUOS
TRANSITION BETWEEN ELEMENTS.
2. DRAWINGS USE ABBREVIATED CODES (FOR EXAMPLE,
P1) TO IDENTIFY MATERIALS AND PRODUCTS. REFER TO
THE SPECIFICATIONS FOR CODE DEFINITIONS.
3. FLOOR FINISH NOTES AND CODES:
A. EXTEND FLOOR FINISH UNDER CASEWORK
EXCEPT WHERE INTEGRAL BASE OCCURS.
B. CENTER FLOOR TRANSITIONS UNDER DOOR IN
CLOSED POSITION UNLESS NOTED OTHERWISE.
C. PROVIDE FLOOR LEVELING PRIOR TO FLOOR
FINISH INSTALLATION.
D. REFER TO FIRE PROTECTION DRAWINGS FOR
ADDITIONAL INFORMATION ON FLOOR DRAINS.
E. REFER TO VA STANDARD AND INTERIOR
DESIGNER FOR INITIAL DETERMINATION OF
COLOR SELECTION AND SURFACE TEXTURE.
F. REFER TO SPEC SECTION 09 06 00 SCHEDULE
FOR FINISHES FOR MORE INFORMATION.
FINISH PLAN NOTES
FLOOR FINISH CODES
FLOOR FINISHES ARE INDICATED WITH HATCH PATTERNS. SEE
FINISH KEY BELOW
BASE FINISH CODES
RB - RESILIENT BASE
WALL FINISH CODES
WHERE ONE TYPE OF WALL FINISH IS USED THROUGHOUT A
ROOM, THE FINISH CODE IS INDICATED ONLY IN THE ROOM
IDENTIFICATION TAG. WHERE MULTIPLE WALL FINISHES OCCUR,
WALL FINISH SYMBOLS ARE USED FOR EACH WALL.
P# - PAINT
PT - PORCELAIN TILE (FLOOR AND BASE)
WD - WOOD
RWC - RIGID VINYL WALL PROTECTION SHEET
SS - SOLID SURFACE
PLAN LEGEND
ROOM NAMEROOM NAME
ROOM NUMBER
FLOOR FINISH
BASE FINISH
WALL FINISH
ROOM IDENTIFICATION
TAG, CONSISTING OF:
FLOOR FINISH & DRAIN
LEGEND
RES 6A - RESILIENT FLOOR FINISH
LVT- LUXURY VINYL TILES
CORNER GUARD
WALL PROTECTION
NOT IN CONTRACT
SCOPE LEGEND
CEILING FINISH
FLOOR FINISH ABBREVIATION
RES 6A - RESILIENT FLOOR FINISH
LVT - LUXURY VINYL TILES
EXISTING - EXISTING FLOORING
ACT 1 - ACOUSTICAL CEILING TILE (REGULAR)
ACT 2 - ACOUSTICAL CEILING TILE (WATERPROOF)
RB- RESILIENT BASE
SSP- STAINLESS STEEL WALL PANEL
FLOOR TRANSITION
TYPES OF FLOOR DRAINS (FOR
ADDITIONAL DETAILS, REFER TO
MECHANICAL DRAWINGS.
SIGNAGE
IDENTIFICATION TAG
ROOM NUMBER
1 LEVEL THE OPEN OFFICE FLOOR BEFORE PLACING
FLOOR FINISH.
STAINLESS STEEL WALL PROTECTION PER 3/AE-501.
FLOOR FINISH KEYNOTE
3603 NW 98th Street, Suite B Gainesville, FL 32606 Phone: (352) 474-6124 Fax: (352) 553-4437
COA: FL #29758
AKEA Design Project No. AD213-23
Design, Inc.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
RENOVATE LAKE NONA
BUILDING 2 FOR CANTEEN
ORLANDO, FLORIDA
OF
ARCHITECT - OF - RECORD FL. REG. NO.
675-23-103
FINAL CONSTRUCTION
DRAWINGS
This item has been electronically signed and sealed by the individual named at right.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
8/
/2
1:
:1
PM
JRF SNG
JENNIFER R. FONG AR97191
AF-121
LEVEL 1, AREA D3 - FINISH FLOOR PLAN
8 69AUGUST 22, 2024
SCALE: 1/8" = 1'-0"1 LEVEL 1, AREA D3 - FINISH FLOOR PLAN E1 E2 E3
E4
C1
A3 A2
A1 B1
B2
CLINIC
HOSPITAL
D1 D2 D3
D4 D5 D6
P-W P-E
A4
W
KEY PLAN
NTS
W
Revisions: Date:
Date: 2024.08.28 17:21:59-04'00'
S
S
F
G
H
J
K
L
2627282930313233
32.3
1U701b
OFFICE;
SUPERVISOR
1U701
CASHIER
1U701c
OFFICE; LOANS
1G304
RETAIL STORAGE
1N601
CANTEEN RETAIL
1P105
NUTRITION
THERAPY
1P107
CHIEF FNS
1P103
PROGRAM
MANAGER
1N602
ADMIN CLERKS
1U702c
TRAVEL CLERK
1U702
TRAVEL CLERK
1U702b
AGENT CASHIER
1U702a
AGENT CASHIER
1U303
ELEC
1U301
COMM
1N601b
COMM
1N601a
ELEC
1V112b
COMM
1V112a
ELEC
1V811
ELEC
1U501c
HAC
1U501
PHARMACY
1U501a
CONSULT
1N403
OFFICE (DAV)
1N405
OFFICE
1N406
OFFICE (PVA)
1N203
OFFICE
(FDVA/STATE) 1G302b
TLT & SHWR MALE
1N404
OFFICE (PVA)
1N606
MONEY ROOM
1N608
ASST CHIEF (FOOD)
1V812
NON-FOOD
STORAGE
1V112
DRY STORAGE
1V110
INGREDIENT ROOM
1G304a
HAC
1U701a
VAULT
1V809
ELEC
1M811
CONCESSIONS
1P606
CLEANING EQUIP
1P602
SANITARY SUPPLY
1U302
HAC
1U501b
O.P. SECURE
PRESCRIPTION
STORAGE
1N607
TOILET
1U502
PICK-UP WINDOW
1V712a
RECEIVING OFFICE
1NC06
CORRIDOR
1U301
COMM
1G302a
LOCKERS MALE
1PC02
CORRIDOR
1N605
TOILET
1V106
DETERGENT RM1V102
SODA CLOSET
1V104b
PIZZA OVEN
1P608
HAC1N205
OFFICE
(FAVA/STATE)
1UC05
AISLE
1V811a
ELEC
1UC07
AISLE
1NC02
PASSAGE
1NC04
CORRIDOR
1US01
STAIR - PHARMACY
1VS01
STAIR
1PS01
STAIR
1PE01
ELEVATOR
1PE02
ELEVATOR
1G304b
VESTIBULE
1PC01a
TRAINING AREA
1P110
ASSIST. CHIEF
1P109
DIET TECH/ INTERN
DIRECTOR
1P108
INTERNSHIP
1PC01
AISLE
1P111
DIET TECH
1VC07
AISLE
1P601a
CART/CAN WASH
1P601
DISHWASH
1V721
EXTRACTOR
1P601c
SANITARY SUPPLY
1V702
TRAY ASSEMBLY
1V704
MEAL
CARTS/REFRIGERATOR
1V708
RETHERM
1V802
BULK CARTS
STAGING
1V806
REFRIGERATION/
COMPRESSOR
ROOM
1V803
BULK
REFRIGERATED
STORAGE
1V805
VENDING STORAGE
1V712
RECEIVING
1V805a
VENDING COOLER
1V101
FOOD PRODUCTION
1V101b
POT/PAN WASH
1V103
REFRIGERATED
STORAGE
1V101a
DAY COOLER
1VC08
AISLE
1V105
FREEZER
1P106
CHIEF CANTEEN
1PC06a
ELEV LOBBY
1PC06
CORRIDOR
1V104
SERVERY
1 1
N.I.C.
N.I.C.
N.I.C.
N.I.C.
1V104a
OPEN OFFICE 1
9' - 0"
9' - 0"
9' - 0"
9' - 0"9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
CEILING CEILING
CEILING CEILING
CEILING CEILING
CEILING
CEILING
CEILING
CEILING
AE-501
DEDUCT
ALTERNATE #1 NEW REFLECTED
CEILING PLAN NOTES
1. EXISTING CEILING TILES, LIGHT FIXTURES,
HVAC DIFFUSERS, AND FIRE SPRINKLERS
ARE TO REMAIN UNDISTURBED, EXCEPT
FOR THE AREAS INDICATED ON THE PLAN.
REFER TO MEP ENGINEERING DRAWINGS
AND FIRE SPRINKLER DRAWINGS FOR
ADDITIONAL INFORMATION.
2. PROTECT ALL ITEMS NOT NOTED TO BE
REMOVED (FIELD VERIFY ALL CONDITIONS)
AND COORDINATE ALL WORK WITH THE
GOVERNMENT TO MINIMIZE DISRUPTION
TO EXISTING FACILITIES OPERATIONS.
3. CONTRACTOR TO PATCH, REPAIR, AND
PAINT (REFINISH) SURFACES AND
BUILDING ELEMENTS DAMAGED BY THE
ADDITION OR REMOVAL OF MECHANICAL
AND ELECTRICAL ITEMS. PATCH AND
REPAIR ALL SURFACES TO MATCH
EXISTING SURFACES. NOTIFY COR OF
UNFORESEEN CIRCUMSTANCES.
4. REFER TO MEP DRAWINGS FOR THE
ITEMS THAT NEED TO BE REMOVED/
DEMOLISHED FOR THE AREAS INDICATED
ON THE DEMOLITION CEILING PLAN.
REFLECTED CEILING
PLAN KEYNOTES
NEW CEILING GRID AND TILES. LIGHT FIXTURES,
FIRE SPRINKLERS HEAD, FIRE ALARM,
SPEAKERS, HVAC DIFFUSERS, ETC. PER
ENGINEERS DRAWINGS.
REPLACE CEILINNG TILES AS NEEDED.
EXISTING HOODS TO REMAIN OPERATIONAL AS
APPLICABLE PER CONSTRUCTION PHASE.
LEGEND
NOT IN CONTRACT
3603 NW 98th Street, Suite B Gainesville, FL 32606 Phone: (352) 474-6124 Fax: (352) 553-4437
COA: FL #29758
AKEA…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .