Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT STAMPCONSULTANTS
321 4 5 6 7 8 9 10
523A5-18-371
VAMC BROCKTON
940 BELMONT STREET
BROCKTON, MA 02301
BUILDING 4 ELEVATOR
REPLACEMENT
872 Massachusetts Avenue, Suite 2-9 Cambridge, MA 02139
T: 617.335.5186
William Pevear Architects, Inc.
63 Pleasant Street
T: 617.926.9300
RSE Associates, Inc.
STRUCTURAL:
101 Summer Street
T: 617.574.5099
Van Deusen & Associates
ELEVATOR CONSULTANT:
142 Hanlon Road
T: 508.397.5417
Hastings Consulting, Inc.
CODE CONSULTANT:
Watertown, MA 02472Boston, MA 02210 Holliston, MA 01746
Drawing Scale
08/16/2019
63 Franklin Street
T: 617.542.0810
Architectural Engineers, Inc.
MECH / ELEC / PLUMBING:
Boston, MA 02110
C :\U se rs
\a do rn .W
PA
\D oc um en ts
\V A_
Br oc kt on
_B
El ev at or
U pg ra de
-2
5_ ad or n@ w illi am pe ve ar
.c om
.rv t
/1
2/
0:
:5
AM
4.GI000
Cover
DEPARTMENT OF VETERANS AFFAIRS
VAMC BROCKTON
BUILDING 4 ELEVATOR REPLACEMENT
VA Project # 523A5-18-371 WPA Project # 1628
ARCHITECT
MECH / ELEC / PLUMBING
STRUCTURAL
CODE CONSULTANT
William Pevear Architects, Inc.
872 Massachusetts Avenue, Suite 2-9 Cambridge, MA 02139 T: 617.335.5186
Architectural Engineers, Inc.
63 Franklin Street Boston, MA 02110 T: 617.542.0810 F: 617.542.8451
RSE Associates, Inc.
63 Pleasant Street Watertown, MA 02472 T: 617.926.9300
Hastings Consulting, Inc.
142 Hanlon Road Holliston, MA 01746 T: 508.397.5417
940 Belmont Street Brockton, MA 02301
CONSTRUCTION DOCUMENTS
PROPOSED RENOVATIONS
THIS LOCATION
ELEVATOR CONSULTANT
VDA, Inc. (Van Deusen & Associates)
100 Summer Street, Suite 1600 Boston, MA 02210 T: 617.574.5099
100% SUBMISSION
STANDISH RD
PLYMOUTH AVE
BUILDING #20
N
BUILDING #3 BUILDING #2
BU
IL
DI
NG
#1
BUILDING #4
BELMONT ST
BELMONT ST
MASS AVE
MA
SS
A
VE
MA
NL
EY
S
T
PLYMOUTH AVE
STANDISH RD
MA
NL
EY
S
T
Revisions: Date:
Addendum #1 12/12/2025
Addendum #1 12/12/2025
MATERIAL INDICATIONS
ACOUSTICAL TILE OR PANEL
ALUMINUM
BITUMINOUS CONCRETE
BRICK
CERAMIC TILE
(OMIT AT SMALLER SCALES)
CONCRETE
CONCRETE MASONRY UNIT
EARTH
FLASHING
GLASS
GYPSUM BOARD
INSULATION, BATT OR BLANKET
INSULATION, RIGID
METAL LATH
MORTAR
PLASTIC LAMINATE
PLYWOOD
STEEL
WOOD FINISH
WOOD MILLWORK
WOOD FRAMING THROUGH
MEMBER
WOOD FRAMING
INTERRUPTED MEMBER
WATERPROOFING
SYMBOLS
COLUMN LINE
DOOR SYMBOL
WINDOW SYMBOL WIN
CASEWORK
SYMBOLS
?PAINT COLOR DESIGNATION
PARTITION TYPE SYMBOL B
ELEVATION MARKER TOP OF SLAB
ELEV = X'-X"
DETAIL IDENTIFICATION
SHEET NUMBER
DETAIL CALLOUT
SECTION IDENTIFICATION
SHEET NUMBER
WALL SECTION
SECTION IDENTIFICATION
SHEET NUMBER
BUILDING SECTION
SECTION IDENTIFICATION
SHEET NUMBER
DETAIL
DETAIL
9'-0"CH
TYPECEILING SYMBOL
CEILING TYPE
CEILING HEIGHT
ROOM IDENTIFICATION
Room name
XXXX
XXXX
XXXX
XXXX
Room name
ROOM TAG
ROOM FINISH
IDENTIFICATION
ROOM NAME
ROOM NUMBER
ROOM NAME
CEILING FINISH
WALL FINISH
BASE FINISH
FLOOR FINISH
TYPICAL DOOR; 90 DEGREE OPEN DOOR
180 DEGREE OPEN DOOR
DOORS
SEE DRAWING ---
SEE DRAWING ---
LINETYPES & GRAPHIC FILLS
MATCH LINE
OVERHEAD (OVERCOUNTER AND SOFFITS)
REFERENCE (COLUMN LINES AND MATCHLINES)
BELOW AND BEYOND
(UNDERCOUNTER AND FOOTINGS)
BREAK LINE
LIMIT OF WORK LINE
DOCUMENT REVISION
2 HOUR FIRE RATING
1 HOUR FIRE RATING
SMOKE PARTITION
WALL INDICATIONS
TYPICAL NEW CONSTRUCTION
TYPICAL WINDOW
WINDOW WALL
LOUVER
RECESSED ITEM
DA #?DEDUCT ALT SYMBOL
ELEVATION IDENTIFICATION
SHEET NUMBER
INTERIOR ELEVATION
XXX
EXISTING DOOR
W22M
CASEWORK FAMILY KEY
CASEWORK TYPE KEY
CASEWORK WIDTH KEY
XXX
DA #X
SHEET LIST
X.X
X.X
XX
DETAIL
DETAIL NAME
SCALE 1/8" = 1'-0"
U/S OF DECK STRUCTURE
ACOUSTICAL CEILING TILE
AREA NOT IN SCOPE
TEMPORARY WORK AREA
DEMOLITION AREA
GENERAL NOTES
1. DIMENSIONS TO LOCATE PARTITIONS ARE GIVEN TYPICALLY TO THE FINISHED
FACE. PARTITIONS THAT GRAPHICALLY CENTER ON A GRID OR WINDOW MULLION
ARE TO BE CENTERED AS SHOWN UNLESS OTHERWISE NOTED. NEW PARTITIONS
AND SURFACES THAT ARE SHOWN TO ALIGN WITH EXISTING SURFACES ARE TO BE
ALIGNED AND FINISHED SMOOTH AND FLUSH.
2. CONTRACT LIMIT LINES SHALL BE WHERE INDICATED ON THE
DRAWINGS. HOWEVER, IN ORDER TO COMPLETE OR FACILITATE INDICATED WORK,
CONTRACTOR MAY BE REQUIRED TO CARRY OUT WORK ADJACENT TO, BUT
OUTSIDE INDICATED LIMITS OR TO CONNECT UTILITIES BETWEEN NON
CONTIGUOUS WORK AREAS.
3. COORDINATE THE SIZE AND LOCATION OF ALL TEMPORARY ROOF PROTECTIVE
SURFACES AND WALKWAYS TO PROTECT ROOF, EQUIPMENT AND SYSTEMS.
CHANGE IN
ELEVATION TAG ± 1'-0"
& AND
L ANGLE
@ AT
CENTERLINE
Ø DIAMETER
# NUMBER
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
ALUM ALUMINUM
ALT ALTERNATE
AV AUDIOVISUAL
BOT BOTTOM
BOS BOTTOM OF STEEL
CG CORNER GUARD
CH CEILING HEIGHT
CJ CONTROL JOINT
CLG CEILING
CMU CONCRETE MASONRY UNIT
CO CASED OPENING
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CPT CARPET
CT CERAMIC TILE
CUH CABINET UNIT HEATER
DIA DIAMETER
DN DOWN
DWG DRAWING
E EAST
EIFS EXTERIOR INSULATION & FINISH SYSTEM
EJ EXPANSION JOINT
EP ELECTRICAL PANEL
EQ EQUAL
EQUIP EQUIPMENT
EXIST EXISTING
ETR EXISTING TO REMAIN
F/F FACE TO FACE
FACP FIRE ALARM CONTROL PANEL
FCO FLOOR CLEANOUT
FCU FAN COIL UNIT
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FDV FIRE DEPARTMENT VALVE
FEC FIRE EXTINGUISHER CABINET
FE FIRE EXTINGUISHER
FF FINISH FACE
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FHR FIRE HOSE RACK
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FTR FINNED TUBE RADIATION
G GAS
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GFRC GLASS FIBER REINFORCED CONCRETE
GFRG GLASS FIBER REINFORCED GYPSUM
GWB GYPSUM WALL BOARD
HB HOSE BIBB
HPT HIGH POINT
HR HOUR
HT HEIGHT
HVAC HEATING, VENTILATION, AIR CONDITIONING
HW HOT WATER
ID INSIDE DIAMETER
IF INSIDE FACE
IG INSULATED GLASS
INT INTERIOR
L LEFT
LAB LABORATORY
LPT LOW POINT
MAX MAXIMUM
MECH MECHANICAL
MH MANHOLE
MIN MINIMUM
MO MASONRY OPENING
N NORTH
NIC NOT IN CONTRACT
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED
OF/OI OWNER FURNISHED/OWNER INSTALLED
OFD OVERFLOW DRAIN
OPH OPPOSITE HAND
O OXYGEN
PA PANIC ALARM
QT QUARRY TILE
R RISER
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REF REFRIGERATOR
REQ REQUIRED
RO ROUGH OPENING
RWL RAIN WATER LEADER
S SOUTH
SHR SHOWER
SHRD SHOWER DRAIN
SIM SIMILAR
SS STAINLESS STEEL
STC SOUND TRANSMISSION CLASS
TD TRENCH DRAIN
TOC TOP OF CONCRETE SLAB
TOS TOP OF STEEL
TOW TOP OF WALL
TYP TYPICAL
UL UNDERWRITERS LABORATORIES
UON UNLESS OTHERWISE NOTED
U/S UNDERSIDE
VAC VACUUM
VCT VINYL COMPOSITION TILE
VIF VERIFY IN FIELD
W WEST
WH WALL HYDRANT
ABBREVIATIONS
CL
DEDUCT ALTERNATES
DA#1 EXISTING PASSENGER ELEVATOR TO REMAIN, INCLUDING ALL EQUIPMENT AND FINISHES.
TYPICAL EXISTING WALL
2-HOUR RATED WALL
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT STAMPCONSULTANTS
321 4 5 6 7 8 9 10
523A5-18-371
VAMC BROCKTON
940 BELMONT STREET
BROCKTON, MA 02301
BUILDING 4 ELEVATOR
REPLACEMENT
872 Massachusetts Avenue, Suite 2-9 Cambridge, MA 02139
T: 617.335.5186
William Pevear Architects, Inc.
63 Pleasant Street
T: 617.926.9300
RSE Associates, Inc.
STRUCTURAL:
101 Summer Street
T: 617.574.5099
Van Deusen & Associates
ELEVATOR CONSULTANT:
142 Hanlon Road
T: 508.397.5417
Hastings Consulting, Inc.
CODE CONSULTANT:
Watertown, MA 02472Boston, MA 02210 Holliston, MA 01746
Drawing Scale
08/16/2019
63 Franklin Street
T: 617.542.0810
Architectural Engineers, Inc.
MECH / ELEC / PLUMBING:
Boston, MA 02110
C :\U se rs
\a do rn .W
PA
\D oc um en ts
\V A_
Br oc kt on
_B
El ev at or
U pg ra de
-2
5_ ad or n@ w illi am pe ve ar
.c om
.rv t
/1
2/
0:
:2
AM
12" = 1'-0"
4.GI001
Sheet List and General Notes
SHEET LIST
NUMBER NAME
Current Revision
Name Date
GENERAL INFORMATION
4.GI000 Cover Addendum #1 12/12/2025 4.GI001 Sheet List and General Notes Addendum #1 12/12/2025 4.HA101 Abatement Plan 4.GI110 Construction Access for Penthouse Equipment 4.GI111 General Construction Access & Phase 1 4.GI120 Construction Sequencing & Circulation - Phase 2 & 3
ARCHITECTURAL
4.AD110 Demo Floor Plans and Temp. Work Area Partitions 4.AS110 Floor Plans Addendum #1 12/12/2025 4.AS120 Reflected Ceiling Plans 4.AS410 Interior Elevations Addendum #1 12/12/2025 4.AS701 Elevator Cab Interior Elevations & Details 4.AS801 Elevator Sections and Details Addendum #1 12/12/2025 4.AS802 Door and Partition Schedules, Equipment Schedule, and Interior Details Addendum #1 12/12/2025 4.AS803 Typical Exterior Details 4.AS804 Food Service Ramp
STRUCTURE
4.SS110 Roof / Penthouse Framing Plan 4.SS111 Penthouse Roof Framing Plan & Details
FIRE PROTECTION
4.FA000 Fire Protection Legend, Notes & Abbreviations 4.FD103 Fire Protection Roof / Penthouse Demolition Plan 4.FA203 Fire Protection Roof / Penthouse Plan
PLUMBING
4.PL000 Plumbing Legend, Notes & Abbreviations 4.PL200 Plumbing Pipe Basement Plan
MECHANICAL
4.MH000 Mechanical Legend 4.MD104 Mechanical Roof / Penthouse Demolition Plan 4.MH203 Mechanical Roof / Penthouse Plan 4.MH300 Mechanical Sections 4.MH500 Mechanical Details
ELECTRICAL
4.ES000 Electrical Legend 4.ED100 Electrical Basement and Elevator Pit Demolition Plan 4.ED103 Electrical Roof / Penthouse Demolition Plan 4.ES200 Electrical Basement and Elevator Pit Plan 4.ES203 Electrical Roof / Penthouse Plan 4.ES300 Electrical Conduit Routing Plans 4.ES600 Electrical Systems Diagrams Grand total: 34
Revisions: Date:
Addendum #1 12/12/2025
Addendum #1 12/12/2025 Addendum #1 12/12/2025 Addendum #1 12/12/2025 Addendum #1 12/12/2025 Addendum #1 12/12/2025
Addendum #1 12/12/2025
Addendum #1 12/12/2025
Addendum #1 12/12/2025 Addendum #1 12/12/2025
DN
UP
DN
EXISTING EXTERIOR
COURTYARD
EXISTING
PARKING
EXISTING
PARKING
EXISTING
WARD B
EXISTING
WARD CEXISTING
WARD A
STANDISH RD
PLYMOUTH AVE
CONSTRUCTION VEHICLE ACCESS FOR PENTHOUSE EQUIPMENT
BASEMENT FLOOR
CONSTRUCTION
ACCESS ENTRY
4.GI110
PENTHOUSE
FLOOR ACCESS
EXISTING
BLDG #20
APPROX. LOCATION
OF EXIST. SIGN
4.AS804
R 50
0"
WALKWAY
40' - 0"
STABALIZE CONSTRUCTION
ACCESS AREA
SA3
SA4
SA1
SA2
SA2TEMPORARY
RAMP
AT END OF CONSTRUCTION CONTRACTOR
SHALL RESTORE SITE TO INITIAL CONDITION
PRIOR TO CONSTRUCTION
ALL CRANE ACTIVITY MUST BE PERFORMED WHEN THERE ARE NO
PEOPLE BELOW THE LIFTING. THIS MAY REQUIRE OFF-HOUR CRANE
LIFTING. THIS MAY REQUIRE PROVIDING TEMPORARY PROTECTION OF
THE ROOF TO ENSURE A LIFT DOES NOT PENETRATE ROOF
13 23
15 17 19 21
14 22
K
E
H
G
15b 16 2016b 17b 18 19b 20b 21b
I
F
ELEVATOR MACHINE
PLATFORM
STAIR
ST1A301
ELEVATOR
MACHINE
ROOM
PHA03
EXISTING WARD B EXISTING WARD C
ALCOVE
A119
VAC PUMP
ROOM
PHC04
LOCATION OF EXISTING
PIPING/CONDUIT
EXISTING
EXHAUST FAN
EXISTING MEDIUM
PRESSURE STEAM &
CONDENSATE LINE
OVERHEAD
LOCATION OF
EXISTING MECH.
EQUIPMENT
LOCATION OF EXISTING
ROOF MECH. EQUIPMENT
PROVIDE PROTECTIVE COVER
OVER ROOF FOR ACCESS PATH
TO ELEVATOR MECH. ROOM,
RAMP OVER EXIST.
PIPING/CONDUIT, TYP.
ROOF PENTHOUSE ACCESS
ASSEMBLY AREA
FOR PHASE 2 & 3
PENTHOUSE
EQUIPMENT
PROVIDE TEMP. VENTILATION
FOR SHAFT AS REQ. TO OBTAIN
NEGATIVE PRESSURE
LOCATION OF NEW SPLIT
DUCTLESS CONDENSOR,
SEE MECHANICAL DRAWINGS
LOCATION OF EXISTING
ROOF MECH. EQUIPMENT
ISOLATE AND PROTECT EXISTING
EQUIPMENT IN THIS SPACE FROM DAMAGE
DURING TRANSFER OF EQUIPMENT
ELEVATOR
MACHINE
PLATFORM
PHA04
SA5
SA5
SA5
SA5
PROVIDE 18"x18"x2"
SPLASH BLOCK UNDER
NEW CONDENSATE DRAIN
PROVIDE 3/4" EXTERIOR
GRADE PLYWOOD SHEATHING
OVER MIN. 2" EPS OR SIMILAR
INSULATION OVER EXIST.
ROOF
BUILD UP INSULATION TO RAMP
OVER CONDUITS, PARRAPETS,
AND OTHER ROOF TOP
CONDITIONS AS REQ.
2"-3" COARSE AGGREGATE
MIN. 6" THICK
EX
IS
TI
NG
P
AR
KI
NG
NOTES:
1. THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION THAT WILL PREVENT
TRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC RIGHT-OF-WAYS. THIS MAY
REQUIRE TOP DRESSING, REPAIR AND/OR CLEANOUT OF ANY MEASURES USED
TO TRAP SEDIMENT.
2. WHEN NECESSARY, WHEELS SHALL BE CLEANED PRIOR TO ENTRANCE ONTO
PUBLIC RIGHT-OF-WAY.
3. WHEN WASHING IS REQUIRED IT SHALL BE DONE ON AN AREA STABILIZED WITH
CRUSHED STONE WHICH DRAINS TO AN APPROVED SEDIMENT TRAP OR
SEDIMENT BASIN.
4. RESTORE & REPAIR TO CONDITION PRIOR TO CONSTRUCTION ALL DAMAGED &
MODIFIED SITE ELEMENTS INCLUDING BUT NOT LIMITED TO ROADWAY, PAVING,
STRIPING, CURBS, TREES, SHRUBS, PLANTINGS & GRASSES, SIGNAGE & EDGING.
SITE AND ACCESS KEYNOTES:
EXISTING PARKING SPACES TO BE BLOCKED DURING ROOFTOP EQUIPMENT LOADING / UNLOADING ONLY, PARKING TO REMAIN OTHERWISE. 14-CALENDAR DAY WRITTEN NOTICE TO VA IS REQUIRED TO TAKE OVER PARKING SPACES FOR CRANE ACCESS FOR LOADING/UNLOADING EQUIPMENT.
PROTECT EXISTING STRUCTURES, SITE ELEMENTS, AND TREES FROM DAMAGE. WRAP EXISTING TREES WITH TWO LAYERS OF BURLAP AND WITH TWO LAYERS OF STANDARD SNOW
FENCE, WIRE TO FASTEN SECURELY.
PROVIDE TEMPORARY PREFABRICATED METAL RAMP (WOOD RAMP SYSTEM SHALL BE PROHIBITED) AT BUILDING #20 TO ACCOMODATE FOOD TRANSFER TO BUILDING #4. BASIS OF
DESIGN PRODUCT: AMRAMP, PRO SERIES COMMERCIAL RAMP.
CONTRACTOR TO USE LOADING DOCK FOR EQUIPMENT AND SUPPLY DELIVERIES. CONTRACTOR SHALL COORDINATE SCHEDULE OF DELIVERIES WITH VA AND HAVE LIMIT TIME
AVAILABLE.
SAFETY RAILING SYSTEM: SAFETY RAILING SYSTEM SHALL BE NEW AND REMAIN IN PLACE UNTIL AFTER PROJECT IS COMPLETED. SAFETY RAILING SYSTEM SHALL BE INSTALLED PRIOR TO CONTRACTOR ACCESSING ANY PORTION OF WORK INCLUDING BUT NOT LIMITED TO REPLACEMENT OF ROOF ACCESS DOOR. BASIS OF DESIGN PRODUCT: GARLOCK
RAILGAURD 200 NON-PENETRATING SAFETY GUARDRAIL SYSTEM.
SA1
SA2
SA3
SA4
SA5
SITE AND ACCESS GENERAL NOTES:
1. COORDINATE AND IMPLIMENT ALL SAFETY PROTOCOLS IDENTIFIED BY VA TO ENSURE SAFETY OF WORKERS, STAFF, AND RESIDENTS.
2. STAGING DRAWINGS FOR REFERENCE ONLY. CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY FOR STAGING, DELIVERY, REMOVAL OF EXISTING SALVAGE AND PATCHING AND REPAIRING DAMAGED AND DISTURBED CONDITIONS. PROVIDE COR WITH DETAILED STAGING AND SEQUENCE PLAN. MINIMIZE ON-SITE DISTURBANCE AND EXTERIOR HOSPITAL
INTERRUPTION.
3. CONTRACTOR SHALL VERIFY IN FIELD AND COORDINATE ALL ASPECTS OF STAGING.
4. DELIVERIES AND STAGING SHALL BE JIT (JUST IN TIME). EQUIPMENT DELIVERY AND CONTRACTOR CIRCULATION ROUTES ARE TENTATIVE AND SUBJECT TO OTHER CONCURRENT PROJECTS AT THE TIME WORK COMMENCES. CONTRACTOR MUST COORDINATE WITH VA TO ACCOMPLISH PROJECT GIVEN CONDITIONS AT HAND.
5. EXISTING ROOF WARRANTY: THE CONTRACTOR SHALL ARRANGE WITH TREMCO INC. (508) 243-5062, AND SHALL CARRY ALL RELATED COSTS FOR THE MANUFACTURER'S TECHNICAL INSPECTOR BE ON-SITE TO VERIFY THAT TEMPORARY PROTECTION IS ADEQUATE, AND THAT THE EXISTING ROOF SYSTEM WAS NOT DAMAGED DURING DELIVERY AND REMOVAL OF NEW EQUIPMENT IN ORDER TO CONTINUE COVERAGE OF THE MANUFACTURER'S ROOF SYSTEM WARRANTY FOR THE DURATION OF THE WARRANTY TERMS.
6. DO NOT OVERLOAD EXISTING STRUCTURE - PROVIDE TEMPORARY SUPPORT OF ELEVATOR EQUIPMENT SO LOADING ON EXISTING SLAB DOES NOT EXCEED 100 PSF. COORDINATE
EQUIPMENT PATH AS REQUIRED.
7. EXISTING TO BE SALVAGED MAY BE TEMPORARILY STORED IN PENTHOUSE PENDING COMPLETION OF NEW INSTALL.
8. LOCATION, SWING, AND CAPACITY OF BOOM CRANE OR SIMILAR BY GC.
9. CONTRACTOR SHALL NOT USE ROOF AS STORAGE FOR EQUIPMENT OR SUPPLIES.
10. CONTRACTOR LAYDOWN AREA ALLOWED BUT MAY BE LOCATED OUTSIDE OF CONSTRUCTION SITE. CONTRACTOR SHALL MAKE REQUEST FOR LAYDOWN AREA TO COR WITH NO LESS
THAN 21 DAY NOTICE.
11. PROJECT IS CARRY-IN, CARRY-OUT.
12. CONTRACTOR SHALL COORDINATE CRANE LIFT WITH COR AND PROVIDE MINIMUM 21-DAY NOTICE. CRANE OPERATIONS MAY BE REQUIRED OFF-HOURS TO MINIMIZE DISRUPTIONS TO
HOSPITAL OPERATIONS.
EXIST. TREE: WRAP WITH TWO LAYERS OF
BURLAP AND WITH TWO LAYERS OF STANDARD
SNOW FENCE, WIRE TO FASTEN SECURELY.
TREE PROTECTION
FENCE: USE STANDARD
CHAIN LINK FENSE, 6'HT.
METAL POST TO SUPPORT FENCE,
(6 REQUIRED), DRIVEN INTO THE
GROUND 2'-0" MINIMUM., EQUAL
SPACING AROUND TREE.
8'- 0"
M
IN
9'-4" MIN.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT STAMPCONSULTANTS
321 4 5 6 7 8 9 10
523A5-18-371
VAMC BROCKTON
940 BELMONT STREET
BROCKTON, MA 02301
BUILDING 4 ELEVATOR
REPLACEMENT
872 Massachusetts Avenue, Suite 2-9 Cambridge, MA 02139
T: 617.335.5186
William Pevear Architects, Inc.
63 Pleasant Street
T: 617.926.9300
RSE Associates, Inc.
STRUCTURAL:
101 Summer Street
T: 617.574.5099
Van Deusen & Associates
ELEVATOR CONSULTANT:
142 Hanlon Road
T: 508.397.5417
Hastings Consulting, Inc.
CODE CONSULTANT:
Watertown, MA 02472Boston, MA 02210 Holliston, MA 01746
Drawing Scale
08/16/2019
63 Franklin Street
T: 617.542.0810
Architectural Engineers, Inc.
MECH / ELEC / PLUMBING:
Boston, MA 02110
C :\U se rs
\d co ok .W
PA
\D oc um en ts
\V A_
Br oc kt on
_B
El ev at or
U pg ra de
_d co ok w illi am pe ve ar
.c om
.rv t
8/
/2
:4 9:
A
M
As indicated
4.GI110
Construction Access for Penthouse Equipment
1" = 40'-0"1 Site Plan - Construction Vehicle Access
N
1/8" = 1'-0"2 Penthouse Equipment Plan
SCALE: 1 1/2" = 1'-0"
31 DETAIL - TEMPORARY ROOF PROTECTION
SCALE: 1 1/2" = 1'-0"
32 DETAIL PLAN - CONSTRUCTION ACCESS AREA
NOT TO SCALE
33 DETAIL PLAN - TREE PROTECTION
Revisions: Date:
UP
13 23
15 17 19 21
14 22
K
E
H
G
15b 16 2016b 17b 18 19b 20b 21b
I
F
STAIR
ST1A001
ELEVATOR
LOBBY
A0188
CORRIDOR
CRA001
ELEVATOR
LOBBY
A040
SERVICE
ELEVATOR
S-9
FIRE
CLOSET
FCA001
PASSENGER
ELEVATOR
P-8
EXISTING WARD C
KINESIO
THERAPY
CLINIC
A020
A+C CLINIC
A018
UPPER
PART
SERVICE
ROOM
A017
EQUIPMENT
ROOM
A002
FOOD
CART
STORAGE
A001D
ELEC
A038
OFFICE
A039
TOILET
A019
CORRIDOR
CRA002
PIPE
SPACE
A019A
WOODWORKING
SHOP
A110
MECH
ROOM
A111
OFFICE
A112
TEL
A113
ACCESS
ENTRY
CONSTRUCTION ACCESS
PIPE
SPACE
PHC06
STAIRS
PHC07
STORAGE
PHC08CONFERENCE
ROOM
PHC09
SOILED
LINEN
COLLECTION
PHC10
MECH
ROOM
PHC12
FORMS
ROOM
PHC13
TOILET
PHC17
VESTIBULE
PHC18
RECREATION
PHC19
PM SHOP
PHC20
VESTIBULE
PHC21
OXYGEN
STORAGE
PHC22 OFFICE
PHC23
OFFICE
PHC24
STORAGE
PHC25 OFFICE
PHC26
OFFICE
PHC27
LOUNGE
PHC28
TOILET
PHC29
ALCOVE
PHC30
LOCKER
ROOM
PHC31OFFICE
PHC32
OFFICE
PHC33
OFFICE
PHC34
OFFICE
PHC35 OFFICE
PHC36
KITCHEN
PHC37
TOILET
PHC38
OFFICE
PHC39
OFFICE
PHC40
EXISTING LOADING DOCK
EXISTING 1-HR
SMOKE BARRIER
EXISTING 1-HR
SMOKE BARRIER
4.GI120
0a
STORAGE
PHC41
TEMP.
WORK
AREA
TEMP.
WORK
AREA
17 19
K K
E E
H H
G G
16 2016b 17b 18 19b 20b 21b
I
F
STAIR
ST1A301
ELEVATOR
MACHINE
ROOM
PHA03
ALCOVE
A119
VAC PUMP
ROOM
PHC04
ELEVATOR
MACHINE
PLATFORM
PHA04
PHC04a
PHC04
PHA03
PHA04
C
C
NEW HOISTING BEAM,
SEE STRUCTURAL
PHASE 1 GENERAL SCOPE
1. REFER TO SHEET 4.AD110 FOR DEMO NOTES AND KEY.
2. MODIFY AND INSTALL NEW DOOR PHC04a.
3. PROVIDE NEW RATED PARTITIONS AND DOORS AT PHC04, PHA03, & PHA03a.
4. INSTALL NEW HOISTING BEAM AT ELEVATOR MACHINE PLATFORM.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT STAMPCONSULTANTS
321 4 5 6 7 8 9 10
523A5-18-371
VAMC BROCKTON
940 BELMONT STREET
BROCKTON, MA 02301
BUILDING 4 ELEVATOR
REPLACEMENT
872 Massachusetts Avenue, Suite 2-9 Cambridge, MA 02139
T: 617.335.5186
William Pevear Architects, Inc.
63 Pleasant Street
T: 617.926.9300
RSE Associates, Inc.
STRUCTURAL:
101 Summer Street
T: 617.574.5099
Van Deusen & Associates
ELEVATOR CONSULTANT:
142 Hanlon Road
T: 508.397.5417
Hastings Consulting, Inc.
CODE CONSULTANT:
Watertown, MA 02472Boston, MA 02210 Holliston, MA 01746
Drawing Scale
08/16/2019
63 Franklin Street
T: 617.542.0810
Architectural Engineers, Inc.
MECH / ELEC / PLUMBING:
Boston, MA 02110
C :\U se rs
\d co ok .W
PA
\D oc um en ts
\V A_
Br oc kt on
_B
El ev at or
U pg ra de
_d co ok w illi am pe ve ar
.c om
.rv t
8/
/2
:4 9:
A
M
1/8" = 1'-0"
4.GI111
General Construction Access & Phase 1
1/8" = 1'-0"1 Construction Access - Basement
1/8" = 1'-0"2 Floor Plan - Roof / Penthouse - Phase 1
UP DN
UP DN DN
UP
17 19
K K
E E
H H
G G
16 2016b 17b 18 19b 20b
I
F
STAIR
ST1A001
ELEVATOR
LOBBY
A0188
CORRIDOR
CRA001
SERVICE
ELEVATOR
S-9
FIRE
CLOSET
FCA001
PASSENGER
ELEVATOR
P-8
KINESIO
THERAPY
CLINIC
A020
A+C CLINIC
A018
FOOD
CART
STORAGE
A001D
OFFICE
A039
TOILET
A019
CORRIDOR
CRA002
PIPE
SPACE
A019A
WOODWORKING
SHOP
A110
OFFICE
A112
TEL
A113
PHASE 3
TEMP.
WORK
AREA
+/-32sf
17 19
K K
E E
H H
G G
16 2016b 17b 18 19b 20b
I
F
CORRIDOR
CRA101
ELEVATOR
LOBBY
A100A
STAIR
ST1A101
LOBBY
AREA
A104
PASSENGER
ELEVATOR
P-8
SERVICE
ELEVATOR
S-9
FIRE
CLOSET
FCA101
DINING /
RECREATION
ROOM
C100
DINING /
RECREATION
ROOM
B100
RESPIRATORY
THERAPY
A101A
PREP
STORAGE
A101B
ALCOVE
A101
HAC
152A
CLOSET
A100B
EMPLOYEE
LOCKERS/
CONFERENCE
A107
LOCKER
ROOM
SOCIAL
WORKER
OFFICE
A108
OFFICE
A103
WOMENS
TOILET
A106
MENS
TOILET
A105
VCT
A109
TEL
146A
PHASE 3
TEMP.
WORK
AREA
+/-33sf
US
ER
A
CC
ES
S
17 19
K K
E E
H H
G G
16 2016b 17b 18 19b 20b
I
F
ELEVATOR
LOBBY
A200A
CORRIDOR
CRA201
STAIR
ST1A201
SERVICE
ELEVATOR
S-9
PASSENGER
ELEVATOR
P-8
FIRE
CLOSET
FCA201
STORAGE
250A
RESPIRATORY
THERAPY
A114
DINING
ROOM/
RECREATION
ROOM
C200
DINING
ROOM/
RECREATION
ROOM
B200
TEL
A201
CHASE
CLASS
ROOM
A116
EMPLOYEE
LOCKERS/
CONFERENCE
CLOSET
205A
ELEC
A117
SOCIAL
WORKER
OFFICE
CLOSET
A204A
UTILITY
A118
O.T.
OFFICE
SOCIAL
WORKER
OFFICE
203A
SOCIAL
WORKER
OFFICE
PHASE 3
TEMP.
WORK
AREA
+/-35sf
17 19
K K
E E
H H
G G
16 2016b 17b 18 19b 20b
I
F
STAIR
ST1A301
ELEVATOR
MACHINE
ROOM
PHA03
ALCOVE
A119
VAC PUMP
ROOM
PHC04
APPROX. LOCATION OF
EXISTING ROOF MECH.
EQUIPMENT
TEMP.
ASSEMBLY /
STORAGE FOR
PHASE 1 & 2
ELEVATOR
MACHINE
PLATFORM
PHA04
PHASE 3
TEMP. WORK
AREA +/-130sf
17 19
K K
E E
H H
G G
16 2016b 17b 18 19b 20b
I
F
STAIR
ST1A001
ELEVATOR
LOBBY
A0188
CORRIDOR
CRA001
ELEVATOR
LOBBY
A040
SERVICE
ELEVATOR
S-9
FIRE
CLOSET
FCA001
PASSENGER
ELEVATOR
P-8
KINESIO
THERAPY
CLINIC
A020
A+C CLINIC
A018
FOOD
CART
STORAGE
A001D
OFFICE
A039
TOILET
A019
CORRIDOR
CRA002
PIPE
SPACE
A019A
WOODWORKING
SHOP
A110
OFFICE
A112
TEL
A113
PHASE 2
TEMP.
WORK AREA
+/-26sf
EXIT DOOR TO SECURE
OUTDOOR SPACE
STORAGE
PHC41
17 19 21
K K
E E
H H
G G
2017b 18 19b 20b 21b
I
F
CORRIDOR
CRA101
ELEVATOR
LOBBY
A100A
STAIR
ST1A101PASSENGER
ELEVATOR
P-8
SERVICE
ELEVATOR
S-9
FIRE
CLOSET
FCA101
DINING /
RECREATION
ROOM
C100
DINING /
RECREATION
ROOM
B100
RESPIRATORY
THERAPY
A101A
PREP
STORAGE
A101B
ALCOVE
A101
HAC
152A
CLOSET
A100B
WOMENS
TOILET
A106
VCT
A109
QUIET
ROOM
TEL
146A
CHASE
PHASE 2
TEMP. WORK
AREA +/-95sf
TEMP. EXIT THRU
DINING/RECREATION
ROOM DURING PHASE 2
DOORS TO BE TEMPORARILY
LOCKED DURING PHASE 2
US
ER
A
CC
ES
S
NOTE: OPTION FOR ACCESS ROUTE
THRU OTHER DINING/RECREATION
ROOM AS NEEDED
17 19 21
K K
E E
H H
G G
2017b 18 19b 20b 21b
I
F
ELEVATOR
LOBBY
A200A
CORRIDOR
CRA201
STAIR
ST1A201
SERVICE
ELEVATOR
S-9
PASSENGER
ELEVATOR
P-8
FIRE
CLOSET
FCA201
STORAGE
250A
RESPIRATORY
THERAPY
A114
DINING
ROOM/
RECREATION
ROOM
C200
TEL
A201
CHASE
CLASS
ROOM
A116
QUIET
ROOM
SOCIAL
WORKER
OFFICE
UTILITY
A118
SOCIAL
WORKER
OFFICE
PHASE 2
TEMP. WORK
AREA +/-94sf
TEMP. EXIT THRU
DINING/RECREATION
ROOM DURING PHASE 2
DOOR TO BE TEMPORARILY
LOCKED DURING PHASE 2
NOTE: OPTION FOR ACCESS ROUTE
THRU OTHER DINING/RECREATION
ROOM AS NEEDED
17 19
K K
E E
H H
G G
16 2016b 17b 18 19b 20b
I
F
STAIR
ST1A301
ELEVATOR
MACHINE
ROOM
PHA03
ALCOVE
A119
VAC PUMP
ROOM
PHC04
APPROX. LOCATION OF
EXISTING ROOF MECH.
EQUIPMENT
TEMP.
ASSEMBLY /
STORAGE FOR
PHASE 1 & 2
ELEVATOR
MACHINE
PLATFORM
PHA04
PHASE 2
TEMP. WORK
AREA +/-200sf
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT STAMPCONSULTANTS
321 4 5 6 7 8 9 10
523A5-18-371
VAMC BROCKTON
940 BELMONT STREET
BROCKTON, MA 02301
BUILDING 4 ELEVATOR
REPLACEMENT
872 Massachusetts Avenue, Suite 2-9 Cambridge, MA 02139
T: 617.335.5186
William Pevear Architects, Inc.
63 Pleasant Street
T: 617.926.9300
RSE Associates, Inc.
STRUCTURAL:
101 Summer Street
T: 617.574.5099
Van Deusen & Associates
ELEVATOR CONSULTANT:
142 Hanlon Road
T: 508.397.5417
Hastings Consulting, Inc.
CODE CONSULTANT:
Watertown, MA 02472Boston, MA 02210 Holliston, MA 01746
Drawing Scale
08/16/2019
63 Franklin Street
T: 617.542.0810
Architectural Engineers, Inc.
MECH / ELEC / PLUMBING:
Boston, MA 02110
C :\U se rs
\d co ok .W
PA
\D oc um en ts
\V A_
Br oc kt on
_B
El ev at or
U pg ra de
_d co ok w illi am pe ve ar
.c om
.rv t
8/
/2
:5 0:
A
M
1/8" = 1'-0"
4.GI120
Construction Sequencing & Circulation - Phase 2 & 3
1/8" = 1'-0"0a Floor Plan - Basement - Phase 3 1/8" = 1'-0"1a Floor Plan - First Floor - Phase 3
1/8" = 1'-0"2a Floor Plan - Second Floor - Phase 3 1/8" = 1'-0"3a Floor Plan - Roof / Penthouse - Phase 3
1/8" = 1'-0"0b Floor Plan - Basement - Phase 2 1/8" = 1'-0"1b Floor Plan - First Floor - Phase 2
1/8" = 1'-0"2b Floor Plan - Second Floor - Phase 2 1/8" = 1'-0"3b Floor Plan - Roof / Penthouse - Phase 2
DA #1
ELEVATOR MACHINE
PLATFORM
STAIR
ST1A301
ELEVATOR
MACHINE
ROOM
PHA03
ALCOVE
A119
NOT IN SCOPE
NOT IN SCOPE
EXISTING
EXHAUST FAN
EXISTING MEDIUM PRESSURE
STEAM OVERHEAD
EXISTING CONDENSATE LINE
OVERHEAD
APPROX. LOCATION OF
EXISTING MECH. EQUIP
ST1A301
PHC04
PHC04a
PHC03
UP
SERVICE
ELEVATOR
S-9
PASSENGER
ELEVATOR
P-8
36"x36" METAL ACCESS
DOOR AND FRAME
SERVICE
ROOM
A017
LINE OF UPPER PART SERVICE ROOM
BASEMENT LEVEL - SEE SHEET 4.GI111
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT STAMPCONSULTANTS
321 4 5 6 7 8 9 10
523A5-18-371
VAMC BROCKTON
940 BELMONT STREET
BROCKTON, MA 02301
BUILDING 4 ELEVATOR
REPLACEMENT
872 Massachusetts Avenue, Suite 2-9 Cambridge, MA 02139
T: 617.335.5186
William Pevear Architects, Inc.
63 Pleasant Street
T: 617.926.9300
RSE Associates, Inc.
STRUCTURAL:
101 Summer Street
T: 617.574.5099
Van Deusen & Associates
ELEVATOR CONSULTANT:
142 Hanlon Road
T: 508.397.5417
Hastings Consulting, Inc.
CODE CONSULTANT:
Watertown, MA 02472Boston, MA 02210 Holliston, MA 01746
Drawing Scale
07/17/2019
63 Franklin Street
T: 617.542.0810
Architectural Engineers, Inc.
MECH / ELEC / PLUMBING:
Boston, MA 02110
C :\U se rs
\d co ok .W
PA
\D oc um en ts
\V A_
Br oc kt on
_B
El ev at or
U pg ra de
_d co ok w illi am pe ve ar
.c om
.rv t
6/
/2
2:
:4
PM
Plans
Revisions: Date:
1/4" = 1'-0"1 Existing Floor Plan - Roof / Penthouse
1/4" = 1'-0"2 Existing Floor Plan - Pipe Basement
Abatement Plan
4.HA101
Project Director
MFD DJA
Mabbett & Associates, Inc.
5 Alfred Circle Bedford, MA 01730-2318
T. 781-275-6050 www.mabbett.com
1/4" = 1'-0"
Crawlspace Abatement Notes:
Penthouse Abatement Notes:
HATCHED AREAS INDICATE POSITIVE DETECTION OF ASBESTOS
CONTAINING BUILDING COMPONENTS
REMOVE VISIBLE DEBRIS AND INSTALL EPDM ISOLATION MEMBRANE
OVER CONTAMINATED SOIL.
Hazardous Materials Legend
E
H
G
15b 16 2016b 17b 18 19b 20b 21b
I
F
PROVIDE LOOSE LINTEL AT NEW
DUCT OPENING IN EXISTING WALL
PROVIDE TEMP SUPPORT OF ELEVATOR EQUIPMENT SO
LOADING ON EXISTING SLAB DOES NOT EXCEED 100 PSF.
COORDINATE EQUIPMENT PATH AS REQUIRED
PROVIDE LOOSE LINTEL AT
ENLARGED DOOR OPENING IN
EXISTING WALL
(3) L4x3-1/2x5/16 (GALV)
(3 ) L
4x 3-
1/ 2x
5/
(G
AL
V)
1' - 9"
1'
9"8"
8" 7"
7" 1'
9"
1' - 9"
PROPOSED OPENING IN EXISTING SLAB. LOCATE
EXISTING REBAR AND ADJUST OPENING LOCATION
SO AS TO CUT NO MORE THAN 2 BARS EACH WAY.
COORDINATE SLAB OPENINGS WITH EXISTING
SHEAVE BEAMS AND PROPOSED EQUIPMENT.
PROPOSED OPENING IN EXISTING SLAB. LOCATE
EXISTING REBAR AND ADJUST OPENING LOCATION
SO AS TO CUT NO MORE THAN 2 BARS EACH WAY.
COORDINATE SLAB OPENINGS WITH EXISTING
SHEAVE BEAMS AND PROPOSED EQUIPMENT.
H
G
17b 18 19b
I
F
10"
24"x24" SUMP PIT
8"
10" 3"
24"x24" SUMP PIT
4.SS110
8"
3"
FACE OF PIT WALL
#4 NOSING DRILL AND EPOXY
INTO EXISTING SLAB/WALL EA
END, TYP (4) SIDES.
FACE OF PIT WALL
TYP
FACE OF PIT WALL
FACE OF PIT WALL
#4 NOSING DRILL AND EPOXY
INTO EXISTING SLAB/WALL EA
END, TYP (4) SIDES.
8"
VIF
1' - 2"
VIF
4"
6"
6" CIP CONC SLAB & WALLS
REINF W/ #4@12" OC EW
DRILL AND EPOXY DWL INTO EXIST
#4 NOSING BAR, DRILL AND EPOXY
INTO EXISTING STUCTURE EA END.
TYP (4) SIDES
EXISTING PIT SLAB,
ROUGHEN EDGE
EXISTING PIT WALL
CAST CONCRETE TO
FILL ANY VOIDS DURING
EXCAVATION, TYP ALL
SIDES
PROVIDE WATERSTOP
6" 6"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT STAMPCONSULTANTS
321 4 5 6 7 8 9 10
523A5-18-371
VAMC BROCKTON
940 BELMONT STREET
BROCKTON, MA 02301
BUILDING 4 ELEVATOR
REPLACEMENT
872 Massachusetts Avenue, Suite 2-9 Cambridge, MA 02139
T: 617.335.5186
William Pevear Architects, Inc.
63 Pleasant Street
T: 617.926.9300
RSE Associates, Inc.
STRUCTURAL:
101 Summer Street
T: 617.574.5099
Van Deusen & Associates
ELEVATOR CONSULTANT:
142 Hanlon Road
T: 508.397.5417
Hastings Consulting, Inc.
CODE CONSULTANT:
Watertown, MA 02472Boston, MA 02210 Holliston, MA 01746
Drawing Scale
08/16/2019
63 Franklin Street
T: 617.542.0810
Architectural Engineers, Inc.
MECH / ELEC / PLUMBING:
Boston, MA 02110
C :\U se rs
\S co tt\ D oc um en ts
\1
-0
1- Br oc kt on E le va to r_
R ev
_s co tt.
rv t
8/
/2
2:
:0
PM
As indicated
4.SS110
ROOF / PENTHOUSE FRAMING PLAN
1/4" = 1'-0" 1PENTHOUSE FRAMING PLAN
STRUCTURAL DRAWINGS PROVIDED BY SER SUBMITTED FOR PERMIT DO NOT INCLUDE DESIGN OF THE
SYSTEMS LISTED ABOVE.
D. ALL OTHER SYSTEMS NOTED AS SUCH IN PROJECT SPECIFICATIONS.
C. TEMPORARY SHORING WORK.
B. STRUCTURAL STEEL CONNECTIONS NOT FULLY DETAILED IN CONTRACT DRAWINGS (SHEAR
CONNECTIONS, MOMENT CONNECTIONS).
A. LIGHT GAUGE METAL SYSTEMS
13. THE FOLLOWING SHALL BE DESIGNED BY A REGISTERED DESIGN PROFESSIONAL (RDP) NOT UNDER THE CONTROL OF THE STRUCTURAL ENGINEER OF RECORD (SER) AND SUBMITTED FOR REVIEW WITH
CALCULATIONS PREPARED, STAMPED, AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER
REGISTERED IN THE PROJECT'S STATE:
F. WHERE INDICATED ON THE DRAWINGS OR PROJECT SPECIFICATIONS.
E. WIND BEARING OR LOAD BEARING LIGHT GAUGE METAL FRAMING
D. INSTALLATION OF EXPANSION AND ADHESIVE ANCHORS
C. MASONRY WORK WHERE NOTED ON THE DRAWINGS
B. SHOP WELDING PROCEDURES
A. ALL STRUCTURAL STEEL WELDING AND HIGH STRENGTH BOLTING (EXCEPT METAL STUDS, FURRING, ETC.)
12. THE OWNER WILL RETAIN AN INDEPENDENT TESTING AGENCY TO INSPECT THE FOLLOWING TYPES OF
WORK. SEE THE PROJECT SPECIFICATIONS FOR SPECIFIC REQUIREMENTS.
11. SEE ARCHITECTURAL DRAWINGS FOR WATERPROOFING AND DAMPPROOFING DETAILS.
MECHANICAL AREAS.......................................... 200 PSF
STORAGE AREAS................................................ 125 PSF
FLOORS................................................................ 100 PSF
ROOFS.................................................................. 20 PSF
LIVE LOAD
DESIGN IS IN ACCORDANCE WITH THE MASSACHUSSETS STATE BUILDING CODE, 9TH ED.
10. DESIGN BASIS:
9. ALL MECHANICAL SYSTEMS SUSPENDED LOADS EXCEEDING 100 POUNDS SHALL BE REVIEWED BY THE
STRUCTURAL ENGINEER PRIOR TO INSTALLATION UNLESS SPECIFICALLY DETAILED ON THE...
8. OPENING, POCKETS, ETC. LARGER THAN 6" SHALL NOT BE PLACED IN CONCRETE SLABS, DECKS, OR WALLS UNLESS SPECIFICALLY DETAILED ON THE STRUCTURAL DRAWINGS. NOTIFY THE STRUCTURAL ENGINEER WHEN DRAWINGS BY OTHERS SHOW OPENINGS, POCKETS, ETC LARGER THAN 6" WHICH
ARE NOT SHOWN ON THE STRUCTURAL DRAWINGS, BUT WHICH ARE LOCATED IN STRUCTURAL...
D. SIZE AND LOCATION OF MACHINE OR EQUIPMENT BASES, ANCHOR BOLTS FOR MOTOR MOUNTS, EXCEPT AS SHOWN OR NOTED.
C. CONCRETE INSERTS FOR ELECTRICAL, MECHANICAL, OR PLUMBING FIXTURES.
B. ELECTRICAL CONDUIT RUNS, BOXES, OUTLETS IN WALLS AND SLABS
A. PIPE AND DUCT RUNS, SLEEVES, HANGERS, TRENCHES, WALL AND SLAB OPENINGS, ETC. EXCEPT
AS SHOWN OR NOTED.
7. SEE THE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR THE FOLLOWING:
F. DIMENSIONS NOT SHOWN ON STRUCTURAL DRAWINGS.
E. FINISHED FLOOR AND EXTERIOR ELEVATIONS.
D. FLOOR AND ROOF FINISHES.
C. SIZE AND LOCATION OF ALL DOOR AND WINDOW OPENINGS EXCEPT AS SHOWN.
B. SIZE AND LOCATION OF ALL CONCRETE CURBS, FLOOR DRAINS, SLOPES, INSERTS, ETC. EXCEPT AS
SHOWN.
A. SIZE AND LOCATION OF ALL INTERIOR AND EXTERIOR NON BEARING PARTITIONS.
6. SEE THE ARCHITECTURAL DRAWINGS FOR THE FOLLOWING:
5. IN THE EVENT THAT CERTAIN DETAILS OF THE CONSTRUCTION ARE NOT FULLY SHOWN OR NOTED ON THE DRAWINGS, THEIR CONSTRUCTION SHALL BE OF THE SAME TYPE AS FOR SIMILAR CONDITIONS...
4. THE CONTRACTOR SHALL SUBMIT COMPLETE SHOP DRAWINGS FOR THE ENGINEER'S APPROVAL FOR ALL PARTS OF THE WORK, INCLUDING A DESCRIPTION OF DEMOLITION, CONSTRUCTION METHODS, AND SEQUENCING WHERE APPLICABLE. EXISTING FIELD CONDITIONS SHALL BE INCORPORATED INTO SUBMITTALS. NO PERFORMANCE OF THE WORK INCLUDING, BUT NOT LIMITED TO, DEMOLITION OF THE
EXISTING STRUCTURE, OR FABRICATION OR ERECTION OF NEW STRUCTURAL ELEMENTS SHALL
COMMENCE WITHOUT REVIEW OF THE SHOP DRAWINGS BY THE ENGINEER.
3. ALL WORK IS TO BE CARRIED OUT IN ACCORDANCE WITH THE SPECIFICATIONS AND THE
MASSACHUSETTS STATE BUILDING CODE, 9TH ED.
2. THE CONTRACTOR SHALL COMPARE STRUCTURAL DRAWINGS WITH THE ARCHITECTURAL DRAWINGS BEFORE COMMENCING WITH THE WORK AND SHALL NOTIFY THE ARCHITECT AND ENGINEER OF ANY DISCREPANCIES REQUIRING CLARIFICATION OR REVISIONS. DO NOT SCALE STRUCTURAL DRAWINGS.
REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS NOT SHOWN.
1. CONTRACTOR SHALL DETERMINE EXISTING CONDITIONS WHERE REQUIRED AND VERIFY ALL FIELD
CONDITIONS FOR CLEARANCES, DIMENSIONS AND ELEVATIONS SHOWN ON DRAWINGS. ANY
DISCREPANCIES SHALL BE MARKED ON A PRINT OF THE STRUCTURAL DRAWING AND FORWARDED
IMMEDIATELY TO THE ENGINEER.
GENERAL NOTES
4. SHEETING, SHORING AND BRACING FOR THE LATERAL SUPPORT OF EXCAVATION SHALL REMAIN IN PLACE UNTIL ALL PERMANENT STRUCTURAL SYSTEMS AT AND BELOW GROUND LEVEL ARE COMPLETE.
FOR FURTHER INFORMATION ON LATERAL SUPPORT OF EXCAVATION, SEE SPECIFICATIONS.
3 CONSTRUCTION LOADS SHALL NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT. PROVIDE ADEQUATE SHORING AND/OR BRACING WHERE STRUCTURE HAS NOT ATTAINED DESIGN STRENGTH.
2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE PROPER SHORING AND BRACING
WHEREVER NECESSARY. SHOP DRAWINGS FOR SUCH SHORING SHALL BE PREPARED BY A
PROFESSIONAL ENGINEER RETAINED BY THE CONTRACTOR, IN ACCORDANCE WITH ALL APPLICABLE
CURRENT RULES AND REGULATIONS.
1. ALL TEMPORARY WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE
MASSACHUSETTS STATE BUILDING CODE, 9TH ED.
TEMPORARY WORK
15. SUBMIT SHOP DRAWINGS TO ARCHITECT FOR REVIEW AND OBTAIN ACCEPTANCE PRIOR TO START OF
FABRICATION.
14. SHOP PAINTING OF STEEL IS NOT REQUIRED UNLESS OTHERWISE NOTED.
13. ALL STEEL EXPOSED TO THE WEATHER IN THE COMPLETED BUILDING SHALL BE COATED WITH ZINC RICH
PRIMER UNLESS NOTED OTHERWISE.
12. STRUCTURAL STEEL FRAMING SHALL BE TRUE AND PLUMB BEFORE CONNECTIONS ARE FINALLY BOLTED
OR WELDED.
11. CONTRACTOR SHALL FURNISH ALL PLATES, CLIP ANGLES, CONNECTIONS, ETC. REQUIRED FOR THE
COMPLETION OF THE STRUCTURE EVEN IF EVERY SUCH ITEM IS NOT SHOWN ON THE CONTRACT
DOCUMENTS.
10. FIELD CUTTING OF STRUCTURAL STEEL OR ANY FIELD MODIFICATIONS OF STRUCTURAL STEEL SHALL NOT BE MADE WITHOUT PRIOR WRITTEN APPROVAL BY ARCHITECT FOR EACH SPECIFIC CASE. NO TORCH CUTTING SHALL BE ALLOWED IN THE FIELD EXCEPT FOR SPECIFIC LOCATIONS SHOWN ON THE DRAWINGS FOR PORTIONS OF EXISTING BEAMS TO BE REMOVED. GRIND ALL FIELD CUTS OF STEEL TO BE SMOOTH.
9. REFER TO STEELWORK SPECIFICATIONS FOR STEELWORK PROTECTION AND COATINGS.
8. WELD LENGTHS CALLED FOR ON PLANS ARE THE NET EFFECTIVE LENGTH REQUIRED. ALL BUTT WELDS
SHALL BE FULL PENETRATION UNLESS OTHERWISE NOTED. ALL GROOVE WELDS SHALL BE FULL
PENETRATION UNLESS OTHERWISE NOTED. FILLET WELDS SHALL BE A MINIMUM OF 3/16".
7. ALL WELDED CONNECTIONS SHALL CONFORM TO THE AWS.D1.1 LATEST EDITION. ALL WELDERS SHALL BE
LICENSED AND QUALIFIED AS REQUIRED BY GOVERNING CODES.
6. WELDING ELECTRODES SHALL CONFORM TO AWS E70XX ELECTRODES OR AS OTHERWISE REQUIRED BY THE SPECIFICATIONS, WHERE WELD LENGTH IS NOT SHOWN, IT SHALL BE THE FULL LENGTH OF THE JOINT.
d. SIMPLE SHEAR CONNECTION SHALL BE CAPABLE OF END ROTATION PER AISC REQUIREMENTS FOR
"UNRESTRAINED MEMBERS."
c. SHEAR CONNECTIONS FOR OTHER MEMBERS SHALL BE SIMPLE SHEAR CONNECTIONS WITH EITHER SLIP CRITICAL TYPE HIGH STRENGTH BOLTS OR BEARING TYPE HIGH STRENGTH BOLTS (ASSUME
THREADS INCLUDED IN SHEAR PLANE FOR ALLOWABLE VALUES.)
b. STANDARD, OVERSIZED, OR HORIZONTAL SHORT SLOTTED HOLES IN WEBS OF BEAMS
a. 3/4 INCH MINIMUM BOLT DIAMETER, TWO BOLTS MINIMUM
5. BOLTED CONNECTIONS SHALL BE AS FOLLOWS:
HIGH STRENGTH BOLTS ASTM A325 OR A490
ANGLES, CHANNELS, PLATES AND BARS ASTM A36
WIDE FLANGE ROLLED SHAPES ASTM A992 GRADE 50
4. STRUCTURAL STEEL SHALL BE THE FOLLOWING GRADES:
3. STRUCTURAL STEEL SHALL BE DETAILED IN ACCORDANCE WITH "DETAILING FOR STEEL CONSTRUCTION
(AISC)" AND, WHERE REQUIRED, DESIGNED IN ACCORDANCE WITH THE CITED REFERENCES.
2. STRUCTURAL STEEL WORK SHALL CONFORM TO "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS (AISC 2010)"; "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS & BRIDGES (AISC 2010)"; AND
"STRUCTURAL WELDING CODE - STEEL (AWS D1.1-94)"
1. STRUCTURAL STEEL WORK SHALL CONFORM TO THE REQUIREMENTS OF THESE NOTES, THE
SPECIFICATIONS, AND THE MASSACHUSETTS STATE BUILDING CODE, 9TH ED.
STRUCTURAL STEEL
1/4" = 1'-0" 2BASEMENT FLOOR PLAN
1/2" = 1'-0" 3SECTION - SUMP PIT SLAB
G
15b 16 2016b 17b 18 19b 20b 21b
I
F
W 8x
4.SS111H
O
IS
TI
N
G B
EA
M
WELD W BEAM TO ANCHOR PLATE
FASTENED TO EXISTING COLUMN.
TYPICAL EACH END
VI
F
BE
AM
L
EN
G
TH
Roof 339' - 11 1/4"1 5/8"
1"
1/
2"
EXISTING CONC
RIBBED SLAB
EXISTING 12"x12"
CONC COLUMN
W8x15 HOISTING BM
PROVIDE 3/8" SHEAR TAB
W/ (2) 3/4"Ø A325 BOLTS
HOISTING BM
4.SS111
TYP
TY
P
1/
4"
B.O. EXIST SLAB
ANCHOR PLATE
CENTER ON COLUMN
G
1/2"Ø HILTI HIT-Z ANCHOR
EMBED = 4 3/4"
PL 3/8"x2 1/2"x2 1/2"
PLATE WASHER
W/ STD HOLES
PL 3/4"x10"x1'-5 1/4"
ANCHOR PLATE
W/ OVS HOLES
EXIST 12"x12"
CONC COLUMN
DO NOT CUT REBAR WHEN
DRILLING ANCHORS
2" 2"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT STAMPCONSULTANTS
321 4 5 6 7 8 9 10
523A5-18-371
VAMC BROCKTON
940 BELMONT STREET
BROCKTON, MA 02301
BUILDING 4 ELEVATOR
REPLACEMENT
872 Massachusetts Avenue, Suite 2-9 Cambridge, MA 02139
T: 617.335.5186
William Pevear Architects, Inc.
63 Pleasant Street
T: 617.926.9300
RSE Associates, Inc.
STRUCTURAL:
101 Summer Street
T: 617.574.5099
Van Deusen & Associates
ELEVATOR CONSULTANT:
142 Hanlon Road
T: 508.397.5417
Hastings Consulting, Inc.
CODE CONSULTANT:
Watertown, MA 02472Boston, MA 02210 Holliston, MA 01746
Drawing Scale
08/16/2019
63 Franklin Street
T: 617.542.0810
Architectural Engineers, Inc.
MECH / ELEC / PLUMBING:
Boston, MA 02110
C :\U se rs
\S co tt\ D oc um en ts
\1
-0
1- Br oc kt on E le va to r_
R ev
_s co tt.
rv t
8/
/2
2:
:0
PM
As indicated
4.SS111
PENTHOUSE ROOF FRAMING PLAN &
DETAILS
1/4" = 1'-0" 1PENTHOUSE ROOF FRAMING PLAN
3/4" = 1'-0" 2SECTION - ANCHOR PLATE
3/4" = 1'-0" 3PLAN DETAIL - ANCHOR PLATE
U
UP
E
H
G
17b 18 19b
I
F
STAIR
ST1A001
ELEVATOR
LOBBY
A0188
CORRIDOR
CRA001
SERVICE
ELEVATOR
S-9
FIRE
CLOSET
FCA001
PASSENGER
ELEVATOR
P-8
D04
D04
± 3' - 3 1/2" 8' - 0"
MIN
6' - 0"
MIN
6' - 0"± 2' - 0 1/2"
T
T
TEMPORARILY RELOCATE WALL MTD.
AED TO OUTSIDE OF TEMP. WORK
AREA DURING CONSTRUCTION.
RETURN AED TO EXIST. LOCATION
AFTER COMPLETION OF WORK
AED
PROVIDE FALL PROTECTION AT ALL
OPEN SHAFT LOCATIONS AT ALL
TIMES, TYP.
COORD. PARTITION LOCATION
WITH EXISTING CEILING, TYP.
SEE SHEET 4.AS120, TYP.
E
H
G
17b 18 19b
I
F
CORRIDOR
CRA101
ELEVATOR
LOBBY
A100A
STAIR
ST1A101
PASSENGER
ELEVATOR
P-8
SERVICE
ELEVATOR
S-9
FIRE
CLOSET
FCA101
SMOKE DOOR
D02
D02 D02
D02
D02
D04
D06
D06
± 2' - 6 1/4" ± 8' - 9 1/4"
TEMP. PARTITION TO BE DEMOLISHED
AT END OF PHASE, TYP.
REFER TO SHEET 4.GI120 FOR PHASING
T
E
H
G
17b 18 19b
I
F
ELEVATOR
LOBBY
A200A
STAIR
ST1A201
SERVICE
ELEVATOR
S-9
PASSENGER
ELEVATOR
P-8 FIRE
CLOSET
FCA201
CORRIDOR
C2-1
D01
D01 D01
D01
D01
D04
D06
D07
MI
N
1'
- 6
± 3' - 11 3/4" ± 7' - 3 3/4"
T
E
H
G
15b 16 2016b 17b 18 19b 20b 21b
I
F
ELEVATOR MACHINE
PLATFORM ABOVE ±6'-5"
STAIR
ST1A301
ELEVATOR
MACHINE
ROOM
PHA03
ALCOVE
A119
NOT IN SCOPE
NOT IN SCOPE
EXISTING
EXHAUST FAN
EXISTING MEDIUM PRESSURE
STEAM OVERHEAD
EXISTING CONDENSATE LINE
OVERHEAD
APPROX. LOCATION OF
EXISTING MECH. EQUIP
DEMO GUARD RAIL
CUT OPENING IN EXISTING SLAB,
SEE STRUCTURAL DRAWINGS
FOR SIZING AND COORD.
CUT OPENING IN EXISTING SLAB,
SEE STRUCTURAL DRAWINGS
FOR SIZING AND COORD.
DEMO GUARD RAIL
DEMO GUARD RAIL
DEMO EXISTING ELEVATOR
MACHINE EQUIPMENT
DEMO EXISTING ELEVATOR
MACHINE EQUIPMENT
DEMO EXISTING ELEVATOR
MACHINE EQUIPMENT
ETR
PHC04
PHC04a
D05
D08
NOTE:
SEE SHEET 4.GI110 FOR ACCESS AND
TEMPORARY ROOF PROTECTION
PHC03
CUT OPENING IN WALL
FOR NEW LOUVERS,
SEE MECHANICAL
D08
DEMO WALL TO
UNDERSIDE OF
STRUCTURE
H
G
17b 18
I
F
NOT IN SCOPE
SERVICE
ELEVATOR
S-9
PASSENGER
ELEVATOR
P-8
CORE SLAB, STEM WALL / MASONRY
PARTITION AS REQ. TO ACCOMODATE
NEW EQUIPMENT AND CONNECTIONS,
SEE MEP DRAWINGS
CORE SLAB, STEM WALL / MASONRY
PARTITION AS REQ. TO ACCOMODATE
NEW EQUIPMENT AND CONNECTIONS,
SEE MEP DRAWINGS
DEMOLITION GENERAL NOTES
ICRA GENERAL NOTES
1. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY AND ADDRESS
EXISTING CONDITIONS AS REQUIRED TO ACCOMPLISH THE NEW WORK SHOWN OR
REASONABLY IMPLIED. THE INTENDED SCOPE AREA OF DEMOLITION IS GENERALLY
INDICATED WITH DASHED LINES ON THE DRAWINGS, BUT THIS SCOPE IS DIAGRAMMATIC IN
NATURE AND IS COMPLEMENTED BY THE COMPLETE SET OF CONTRACT DOCUMENTS.
2. THE CONTRACTOR SHALL EXERCISE CARE SO THAT ONLY THE CONSTRUCTION
INDICATED OR REASONABLY IMPLIED TO BE REMOVED SHALL BE DEMOLISHED. THE
EXISTING TO REMAIN SHALL BE LEFT INTACT AND PROTECTED FROM DAMAGE. IN AREAS
WHERE CONSTRUCTION IS IDENTIFIED TO BE REMOVED, STRUCTURAL ELEMENTS SHALL BE
PRESERVED UON.
3. CONTRACTOR SHALL CLEAN SITE OF ALL DEBRIS DAILY. WASTE AND DEBRIS MUST BE
DISPOSED OF IN ACCORDANCE WITH ALL MUNICIPAL, STATE AND FEDEREAL REGULATION.
NO WASTE OR DEBRIS SHALL BE DISPOSED OF ON VA PROPERTY.
4. PRIOR TO DEMOLITION VERIFY W/ COR ALL ELEMENTS IDENTIFIED FOR SALVAGE FOR
REUSE ON THIS PROJECT OR FOR VA USE ELSEWHERE. ALL OTHER EXISTING MATERIALS
INDICATED TO BE REMOVED AND NOT REUSED SHALL BECOME THE PROPERTY OF THE
CONTRACTOR, WHO SHALL REMOVE THEM FROM THE SITE.
5. TAKE ALL PRECAUTIONS TO PREVENT DAMAGE TO EXISTING SURFACES TO REMAIN OR
ANY SALVAGE ITEMS. WHEN REMOVING PORTIONS OF WALL OR CEILINGS TAKE ALL
PRECAUTIONS TO PREVENT STRUCTURAL DAMAGE.
6. ANY DAMAGE TO STRUCTURE, FINISHES, ETC. DUE TO WORK SHALL BE REPAIRED BY
CONTRACTOR AT NO COST TO VA.
7. SEE MEP/FP DRAWINGS FOR SYSTEM DEMOLITION. TAKE ALL PRECAUTIONS TO PREVENT
DAMAGE. REMOVE, REPLACE, OR CAP AS REQUIRED TO PRESERVE SERVICE TO BE
MAINTAINED. IN THE EVENT DAMAGE OCCURS, PATCH ALL SURFACES DISTURBED BY
DEMOLITION.
8. CONTRACTOR TO COORDINATE WITH THE OWNER FOR ANY REQUIRED MEP/FP SYSTEM
SHUT DOWNS AND START-UPS RELEVANT TO DEMOLITION, ESPECIALLY AT THE OCCUPIED
SPACES. CAP OR RECONNECT MEP/FP SYSTEMS SERVING OCCUPIED AREAS OUTSIDE OF
PROJECT SCOPE.
9. PROTECT, PATCH AND REPAIR ALL FINISHES ADJACENT TO THE DEMOLITION AREA.
10. ALL SALVAGED ITEMS TO BE RETURNED TO VA.
DEMOLITION KEYNOTES
BASEMENT / FIRST FLOOR / SECOND FLOOR:
Type C Construction: Work that generates a moderate to high level of dust or requires demolition or removal of any fixed building components or assemblies; Risk Group 2 (VA to confirm) medium risk = Class III ICRA precautions to include:
During Construction:
1. Remove or Isolate HVAC system in area where work is being done to prevent contamination of duct system.
2. Complete all critical barriers i.e. sheetrock, plywood, plastic, to seal area from non-work area or implement control cube method (cart with plastic covering and sealed connection to work site with HEPA vacuum for vacuuming prior to exit) before construction begins.
3. Maintain negative air pressure within work site utilizing HEPA equipped air filtration units.
4. Contain construction waste before transport in tightly covered containers.
5. Cover transport receptacles or carts. Tape covering unless solid lid.
After Construction:
1. Do not remove barriers from work area until completed project is inspected by the owner’s Safety Department and
Infection Prevention & Control Department and thoroughly cleaned by the owner’s Environmental Services Department.
2. Remove barrier materials carefully to minimize spreading of dirt and debris associated with construction.
3. Vacuum work area with HEPA filtered vacuums.
4. Wet mop area with cleaner/disinfectant.
5. Upon completion, restore HVAC system where work was performed.
PENTHOUSE:
Type C construction: Work that generates a moderate to high level of dust or requires demolition or removal of any fixed building components or assemblies; Risk Group 0 (VA to confirm) no risk- patients and medical staff do not have access to penthouse and therefore there should be no risk.
REMOVE WALL COVERING, PREP FOR PAINT.
REMOVE AS REQUIRED TO EFFECT WORK, INCLUDE BUT NOT LIMITED TO: GUARDRAIL SYSTEMS, WALL
PROTECTION, BASE. PATCH AND MATCH UON.
CLEAN AND REMOVE INBEDS AND FASTENERS FROM EQUIPMENT REMOVED.
PROVIDE 2-HOUR RATED TEMPORARY PARTITION SEALED AT FLOOR TO U/S OF STRUCTURAL DECK ABOVE FOR CONSTRUCTION WORK AREA. PATCH AND MATCH AT FLOOR AND CEILING FINISHES AS REQUIRED FOR
UNIFORM FINISH.
REMOVE WALL, DOOR FRAME, AND DOOR AS REQUIRED TO ENLARGE DOOR TO ACCOMODATE EQUIPMENT
REMOVAL AND NEW EQUIPMENT INSTALL. DO NOT MODIFY DOORS IF NOT REQUIRED.
SEAL DOOR OPENING PRIOR TO CONSTRUCTION TO PROTECT FROM DUST AND DEBRIS AS REQ. BY ICRA, PROVIDE CONTRACTOR ACCESS TO WORK AREA ONLY AS REQ.
SALVAGE DOOR LEAF AND SEAL DOOR OPENING PRIOR TO CONSTRUCTION TO PROTECT FROM DUST AND DEBRIS, PROVIDE CONTRACTOR ACCESS TO WORK AREA AS REQ. BY ICRA. REFINISH DOOR LEAF, AND RE-
INSTALL PIOR TO COMPLETION OF PROJECT.
REMOVE PARTITION AND PREP FOR NEW. REMOVE ALL ASSOCIATED CABLES AND PIPING AS REQ. TO
REMOVE PARTITION AND PROVIDE NEW AS NECESSARY.
D01
D02
D03
D04
D05
D06
D07
GENERAL NOTES
1. CONTRACTOR MAY BE REQUIRED TO PERFORM WORK IN AREA DEFINED AS "NOT IN
SCOPE" AS REQ. FOR VARIOUS MINOR MODIFICATIONS, UTILITY CONNECTIONS, AND
GENERAL ACCESS AS MAY BE REQ. TO COMPLETE WORK AS INTENDED.
2. PROVIDE (2) COATS MINIMUM FINISH PAINT (P1) ON PATIENT SIDE ON ALL TEMPORARY
PARTITIONS.
D08
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT STAMPCONSULTANTS
321 4 5 6 7 8 9 10
523A5-18-371
VAMC BROCKTON
940 BELMONT STREET
BROCKTON, MA 02301
BUILDING 4 ELEVATOR
REPLACEMENT
872 Massachusetts Avenue, Suite 2-9 Cambridge, MA 02139
T: 617.335.5186
William Pevear Architects, Inc.
63 Pleasant Street
T: 617.926.9300
RSE Associates, Inc.
STRUCTURAL:
101 Summer Street
T: 617.574.5099
Van Deusen & Associates
ELEVATOR CONSULTANT:
142 Hanlon Road
T: 508.397.5417
Hastings Consulting, Inc.
CODE CONSULTANT:
Watertown, MA 02472Boston, MA 02210 Holliston, MA 01746
Drawing Scale
08/16/2019
63 Franklin Street
T: 617.542.0810
Architectural Engineers, Inc.
MECH / ELEC / PLUMBING:
Boston, MA 02110
C :\U se rs
\d co ok .W
PA
\D oc um en ts
\V A_
Br oc kt on
_B
El ev at or
U pg ra de
_d co ok w illi am pe ve ar
.c om
.rv t
8/
/2
:4 9:
A
M
As indicated
4.AD110
Demo Floor Plans and Temp. Work Area Partitions
1/4" = 1'-0"2 Demo Floor Plan - Basement 1/4" = 1'-0"3 Demo Floor Plan - First Floor
1/4" = 1'-0"4 Demo Floor Plan - Second Floor
1/4" = 1'-0"5 Demo Floor Plan - Roof / Penthouse
1/4" = 1'-0"1 Demo Floor Plan - Pipe Basement
UP DN
UP
E
H
G
17b 18 19b
I
F
STAIR
ST1A001
ELEVATOR
LOBBY
A0188
CORRIDOR
CRA001
ELEVATOR
LOBBY
A040
SERVICE
ELEVATOR
S-9
FIRE
CLOSET
FCA001
PASSENGER
ELEVATOR
P-8
4.AS4101
4.AS4104
4.AS801
4.AS801
4.AS801
4.AS801
4.AS701
4.AS701
5'
- 2 5/
8"
MA
TC
H
EX
IS
T.
4'
- 6
2'
- 8 3/
8"
1'
- 1 1"
6"
4'
- 6 5/
8"
MA
TC
H
EX
IS
T.
3'
- 1 0"
9'
- 1 3/
8"
± 8' - 9 1/2" ± 1' - 2"
EXIST. WATER
FOUNTAIN
P1 P1
P1
P1
E
H
G
17b 18 19b
I
F
CORRIDOR
CRA101
ELEVATOR
LOBBY
A100A
STAIR
ST1A101PASSENGER
ELEVATOR
P-8
SERVICE
ELEVATOR
S-9
FIRE
CLOSET
FCA101
4.AS410
4.AS4109
SMOKE DOOR
4'
- 8 5/
8"
MA
TC
H
EX
IS
T.
4'
- 6
7 3
/8"
2'
- 2
7/ 8"
MA
TC
H
EX
IS
T.
3'
- 1 0"
3'
- 0 5/
8"
1'
- 7
± 9' - 7"
LOBBY
AREA
A104
1'
- 2 1/
2"
8'
- 7
1/ 2"
± 8' - 9 1/2"
P1
P1
P1
P1
P1
E
H
G
17b 18 19b
I
F
ELEVATOR
LOBBY
A200A
CORRIDOR
CRA201
STAIR
ST1A201
SERVICE
ELEVATOR
S-9
PASSENGER
ELEVATOR
P-8 FIRE
CLOSET
FCA201
4.AS410
4.AS41014
4'
- 8 5/
8"
MA
TC
H
EX
IS
T.
4'
- 6
7 3
/8"
4'
- 7
5/ 8"
MA
TC
H
EX
IS
T.
3'
- 1 0"
3/ 8"
± 9' - 9"
1'
- 2 1/
2"
8'
- 7
1/ 2"
± 8' - 9 1/2"
P1
P1
P1
P1
P1
E
H
G
15b 16 2016b 17b 18 19b 20b 21b
I
F
ELEVATOR MACHINE
PLATFORM ABOVE ±6'-5"
STAIR
ST1A301ELEVATOR
MACHINE
ROOM
PHA03
EXISTING
EXHAUST FAN
EXISTING MEDIUM PRESSURE
STEAM OVERHEAD
EXISTING CONDENSATE LINE
OVERHEAD
APPROX. LOCATION OF
EXISTING MECH. EQUIP ALCOVE
A119
4.AS8034
NEW RATED DOOR FOR
EQUIPMENT AT ELEVATOR
MACHINE PLATFORM LEVEL
NOT IN SCOPE
4.AS410 21
4.AS410
4.AS41023
PHA04
NEW FLOOR FINISH AT
ELEVATOR MACHINE
PLATFORM, FLASH
PATCH CONCRETE
DECK AS REQ.
4.AS410 18
4.AS803
C
C
C
C
4.AS803
7'
- 1 1 1
/2"
4"
± 10' - 10" ± 13' - 2 1/2"
ELEVATOR
MACHINE
PLATFORM
PHA04
ALIGN FACE OF
NEW PARTITION W/
EXIST. PARTITION
BELOW
PASSENGER ELEVATOR
P-8 MACHINE
SERVICE ELEVATOR
S-9 MACHINE
(2) MACHINE CONTROLLER, W/
NEW POWER DISCONNECT
ETR
VAC PUMP
ROOM
PHC04PHA04a11
4.AS802
PHC04a
RATED ACCESS PANEL
FOR ACCESS BELOW STAIR
4.AS803
4.AS410 20
4.AS410 24
C
PHA03
REMOVABLE PIPE
GUARDRAIL AT
ACCESS DOOR
EQ-1
EQ-2
EM-S9
EM-P8
EC-P8
EC-S9
4.AS802
4.AS41025
PHC04
C
C1
P3 PTD YELLOW
SAFETY STRIPING
ON FLOOR
P3 PTD YELLOW SAFETY
STRIPING ON FLOOR
4.AS802
4.AS802
4.AS803
4.AS41027
4.AS410
P1P1
4'
- 0 5/
8"
P1
P1
P1
5 1
/4"
P1
P1
P1
P1
P1
P1
P1
P1
P1
P1 P1
P1P1
C1
METAL BAR GRILLE AT
OPENING, FLUSH WITH
FLOOR, OPENINGS SIZED
TO REJECT 1" BALL
METAL BAR GRILLE AT
OPENING, FLUSH WITH
FLOOR, OPENINGS SIZED
TO REJECT 1" BALL
H
G
17b 18
I
F
SERVICE
ELEVATOR
S-9
PASSENGER
ELEVATOR
P-8
9'
- 2
± 8' - 11"
7'
- 8
± 8' - 11"
OIL MINDER SUMP PUMP IN ELEVATOR
PIT W/ CONTROLS LOCATED IN
ELEVATOR MACHINE ROOM
OIL MINDER SUMP PUMP IN ELEVATOR
PIT W/ CONTROLS LOCATED IN
ELEVATOR MACHINE ROOM
CORE SLAB AS REQ. FOR PUMP
CONNECT TO EXIST.,
SEE MEP DRAWINGS
CORE SLAB AS REQ. FOR PUMP
METAL BAR GRILLE AT OPENING,
FLUSH WITH FLOOR, OPENINGS
SIZED TO REJECT 1" BALL
METAL BAR GRILLE AT OPENING,
FLUSH WITH FLOOR, OPENINGS
SIZED TO REJECT 1" BALL
4.AS802
4.AS802
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT STAMPCONSULTANTS
321 4 5 6 7 8 9 10
523A5-18-371
VAMC BROCKTON
940 BELMONT STREET
BROCKTON, MA 02301
BUILDING 4 ELEVATOR
REPLACEMENT
872 Massachusetts Avenue, Suite 2-9 Cambridge, MA 02139
T: 617.335.5186
William Pevear Architects, Inc.
63 Pleasant Street
T: 617.926.9300
RSE Associates, Inc.
STRUCTURAL:
101 Summer Street
T: 617.574.5099
Van Deusen & Associates
ELEVATOR CONSULTANT:
142 Hanlon Road
T: 508.397.5417
Hastings Consulting, Inc.
CODE CONSULTANT:
Watertown, MA 02472Boston, MA 02210 Holliston, MA 01746
Drawing Scale
08/16/2019
63 Franklin Street
T: 617.542.0810
Architectural Engineers, Inc.
MECH / ELEC / PLUMBING:
Boston, MA 02110
C :\U se rs
\a do rn .W
PA
\D oc um en ts
\V A_
Br oc kt on
_B
El ev at or
U pg ra de
-2
5_ ad or n@ w illi am pe ve ar
.c om
.rv t
/1
2/
0:
:0
AM
1/4" = 1'-0"
4.AS110
Floor Plans
1/4" = 1'-0"2 Floor Plan - Basement 1/4" =…