Roof Hatchguard Spec.docx

DOCX document 32 KB Posted

Attached to
Furnish and Install Rooftop Fall Protection Equipment
Solicitation number
D19-033-O
Issued by
Wisconsin

About this file

This is a technical specifications document for roof hatch fall protection equipment required by the University of Wisconsin-Milwaukee as part of a rooftop fall protection furnish and install project. The specification calls for the Safety Rail Company SRC Roof HatchGuard Non-Penetrating Fall Protection system, which includes railings and a self-closing gate designed to protect personnel accessing roof hatches. Two roof hatch sizes are specified: 36 x 42 inches and 36 x 58 inches. The system must comply with OSHA standards including 29 CFR 1910.28(b), 1910.29, 1926.501(b)(4), and 1926.502. Key features of the required equipment include one-piece welded design requiring no assembly, no drilling into the hatch or roof, a 24-inch safe landing zone, built-in grab bars, and a 42-inch nominal height railing system constructed of 2-inch by 14-gauge hot-rolled square tubing. The system must withstand a minimum 200-pound structural load in any direction and include roof pads to protect the membrane.

Contractor responsibilities include field measurements to verify hatch dimensions before fabrication, procurement of crane lift services for rooftop delivery, and securing all necessary permits for traffic control and lane closures during material delivery. The specification requires manufacturer's one-year warranty and submission of manufacturer data sheets, preparation instructions, storage and handling requirements, installation methods, and shop drawings prior to work commencement. Materials must be delivered in undamaged condition in manufacturer's unopened packaging, inspected upon receipt, palletized and labeled by roof level, and stored until installation. The manufacturer must provide American Welding Society certification documentation for AWS D1.1 and AWS D1.3 welding standards prior to shipment. All steel surfaces must be hot-dip zinc galvanized, and installed products must be protected until project completion with damaged items repaired or replaced before substantial completion.

View the file

Other files

File Type Posted
Roof Guardrail Spec.docx DOCX document
D19-033-OA.docx DOCX document
DOA-3832 Bidder Required Form.doc DOC document
D19-033-O.docx DOCX document
Fall Prevention 5-10-2019.pdf PDF
Roof Walkway Spec.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Roof Hatch HatchGuard Railing System Specifications

PART 1 GENERAL

1.1 SECTION INCLUDES

A.Roof Hatch fall protection. (SRC HatchGuard Guarding System)
1.2REFERENCES

A. Occupational Safety & Health Administration (OSHA):

1.29 CFR 1910.28(b) – Duty to Have Fall Protection and Falling Object Protection
2. 29 CFR 1910.29(b) – Fall Protection Systems and Falling Object Protection-criteria and practices.
3.29 CFR 1910.23 – Walking-Working Surfaces - Fixed Ladders.
4.29 CFR 1926.500 - Scope, Application, Definitions Applicable to this Subpart.
5.29 CFR 1926.501 - Duty to Have Fall Protection.
6.29 CFR 1926.502 - Fall Protection Systems Criteria and Practices.
7.29 CFR 1926.503 - Training Requirements.

1.3 SUBMITTALS

A.Manufacturer's data sheets on each product to be used, including:
1.Preparation instructions and recommendations.
2.Storage and handling requirements and recommendations.
3.Installation methods.
B.Shop Drawings: Drawings showing plans, elevations, sections and details of components.
1.4DELIVERY, STORAGE, AND HANDLING
A.Deliver materials to the job site in good condition and adequately protected against damage as handrails are a finished product.
B.Inspect rail sections for damage before signing the receipt from the trucking company. Truck driver must note damaged goods on the bill of lading if damaged product is found.
C.Store products in manufacturer's unopened packaging until ready for installation.

D. Products to be palletized and labeled by roof level or designated drop zone.

1.5PROJECT CONDITIONS
A.Field Measurements: Where handrails and railings are indicated to fit to other construction, check actual dimensions of other construction by accurate field measurements before fabrication.

B. Contractor is responsible for crane lift service to deliver materials to rooftop work areas.

C. Contractor is responsible for procuring all necessary permits for traffic control and lane closures which may be required during crane lift as well as providing all necessary barriers and personnel for vehicular and pedestrian traffic control during crane lifting operations.

1.6WARRANTY
A.Warranty: Provide manufacture's one (2) year warranty.

PART 2 PRODUCTS

2.1 MANUFACTURERS

A.Acceptable Manufacturer: Safety Rail Company, LLC., Spring Park, MN 55384
B.Substitutions: Owner approved substitutions permitted

2.2 SYSTEMS

2.2 ROOF HATCH GUARDING:

A. Provide Safety Rail Company roof hatch guarding including railings and self-closing gate.

1. Product: SRC Roof HatchGuard, Non-Penetrating Fall Protection.

2. Roof Hatch Size (W x L): 36 x 42 in.

3. Roof Hatch Size (W x L): 36 x 58 in.

4. OSHA-compliant fall protection per 29 CFR 1910.2928, CFR 1910.29, 29 CFR 1926.501(b) (4) and 29 CFR 1926.502.

5. One-piece, welded design. No assembly required.

6. No drilling into hatch or roof. Elastomeric tipped compression bolts are tightened against the curb of the roof hatch.

7. Self-closing gate included.

8. 24 inch (610 mm) safe landing zone. Personnel can safely step out of the hatch and gain their footing, prior to engaging the gate.

9. Built-in grab bars.

10. Finish: Steel surfaces.

a. Hot Dip Zinc Galvanized.

B. Roof Hatch Protection: Provide freestanding pedestrian egress barrier system on roof, including railings, bases, and hardware.

1.Approved Product: SRC HatchGuard Rail System or owner approved substitution
2.Standards: System shall have top and mid rail in accordance with OSHA Standards - 29 CFR 1910.29 (b).
3.Structural Load: 200 lb (90.7 kg), minimum, in any direction to all components in accordance with OSHA Regulation 29 CFR 1926.502.
4.Height: 42 inches, nominal.
5.Railings: 2” x 14ga HR square tubing free of sharp edges and snag points with built-in grab bars for safe egress/ingress.
6.Self-closing gate included

7. Quality/Standards Certifications: Manufacturer must be American Welding Society Welding Certified for Welding Standards AWS D1.1 & AWS D1.3 Third party qualification documentation required prior to shipment

2.3 ACCESSORIES

A. Roof Pads: Provide the following pad under each base to protect roof membrane.

2.4 FINISHES

Finish: Hot Dip Zinc Galvanized

PART 3 EXECUTION

3.1 EXAMINATION

A. Do not begin installation until substrates have been properly prepared.

B. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.

3.2 PREPARATION

C. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.

3.3 INSTALLATION

D. Install in accordance with manufacturer's instructions.

3.4 PROTECTION

E. Protect installed products until completion of project.

F. Touch-up, repair or replace damaged products before Substantial Completion.

END OF SECTION