River_Park_Fence_Relocation_Project_Elect.pdf

PDF 2 MB Posted

Attached to
River Park Electrical Relocation
Solicitation number
PK-26-15096-QB
Issued by
Santa Cruz County, California

About this file

River Park Electrical Relocation Project Summary

This is a project description document for the City of Watsonville, California, detailing electrical infrastructure work at River Park located at 100 East Front Street, Watsonville. The project scope encompasses removal of the existing electrical service and installation of new PG&E electrical service infrastructure. Additional work includes installation of electrical conduit to an existing building and minor concrete work associated with the relocation. The project represents a complete electrical service upgrade and relocation effort at the municipal park facility.

The document provides general project overview information establishing the scope of work and location but does not contain detailed specifications regarding project timeline, bidding deadlines, site visit requirements, pre-bid meetings, contract award dates, pricing terms, or contract duration in the materials presented. Interested contractors should refer to the associated state and local contract opportunity listing for complete bidding requirements, submission deadlines, and project specifications necessary to prepare and submit proposals for this electrical relocation work.

View the file

Other files

File Type Posted
River_Park_Electrical_Relocation.pdf PDF
PG&E_Trench_Packet.pdf PDF
Payment_Bond_QB.pdf PDF
Performance_Bond_QB.pdf PDF
Sample_Insurance_Endorsement.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Date

SHEET

of

Approved by

Checked by Scale

Designed by Job No.

PREPARED BY:

DESCRIPTION DATE

REVISIONS: CITY OF WATSONVILLE, CALIFORNIA

PARKS AND COMMUNITY SERVICES

E FRONT ST. WATSONVILLE, CA 95076

RIVER PARK FENCE RELOCATION

1 5 C-1

NEW FENCE PLAN

CITY TO PLACE TEMPORARY CHAIN LINK FENCE

AROUND CONSTRUCTION AREA AND ON

COMMON STAGING AREA

FENCING CONTRACTOR TO INSTALL

NEW 8 FT TALL SECURITY FENCE AT

SAME LOCATION AS EXISTING

CHAIN LINK FENCE SPAN BETWEEN

COMMUNITY GARDEN AND PARK

SCOPE OF WORK

1. DEMOLISH EXISTING MAIN ELECTRICAL SERVICE PANEL

2. DEMOLISH EXISTING CITY OWNED UTILITY POLE

3. PROVIDE AND INSTALL A NEW 200 AMP ELECTRICAL SERVICE PANEL AND RELOCATE/REROUTE EXISTING CONDUCTORS FROM EXISTING BUILDING TO NEW SPLICE BOX

4. PROVIDE AND INSTALL ELECTRICAL UNDERGROUND PER PG&E TRENCH PACKAGE

5. PROVIDE AND INSTALL ALL ELECTRICAL ACCESSORIES REQUIRED TO HAVE A COMPLETE ELECTRICAL SERVICE INSTALLATION

6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE CURRENT ELECTRICAL CODE

FENCING CONTRACTOR TO INSTALL NEW 8 FT

TALL FENCE PRIOR TO DEMOLISH EXISTING FENCE

TO MAINTAIN A SECURE PLAY AREA DURING

CONSTRUCTION

ELECTRICAL CONTRACTOR TO

INSTALL NEW ELECTRICAL PANEL

BOARD. SEE SHEET C-3

FENCING CONTRACTOR TO HAND/VACC EXCAVATE

HOLES WITHIN TREE DRIP LINES. ADJUST POST

LOCATIONS TO MISS ROOTS LARGER THAN 2" DIA.

CLEANLY CUT ROOTS 2" DIA. OR SMALLER WITH

LOPPERS

FENCING CONTRACTOR SHALL NOT INSTALL DOWELS

INTO EXISTING CONCRETE FOUNDATIONS

FENCING CONTRACTOR TO INSTALL STORM DRAIN

INLET FILTER FABRIC PRIOR TO COMMENCING ANY

CONSTRUCTION ACTIVITIES

FENCING CONTRACTOR TO PROVIDE POSITIVE

DRAINAGE AWAY FROM CONCRETE SLAB TO ALLOW

RUNOFF TO FLOW PER EXISTING DRAINAGE

CONDITIONS

FENCING CONTRACTOR TO INSTALL NEW FENCE

FOUNDATIONS STAGGERED FROM EXISTING FENCE

FOUNDATIONS AND PROVIDE SPACING BETWEEN

EXISTING FOUNDATION AND IMPROVEMENTS

of

Approved by

Checked by Scale

Designed by Job No.

PREPARED BY:

DESCRIPTION DATE

REVISIONS: CITY OF WATSONVILLE, CALIFORNIA

PARKS AND COMMUNITY SERVICES

E FRONT ST. WATSONVILLE, CA 95076

RIVER PARK FENCE RELOCATION

2 5 C-2

DEMOLITION PLAN

CITY CREW TO DEMOLISH SECTION OF EXISTING

CONCRETE BASE UP TO NEW FENCE + 250 SF.

CITY CREW TO DEMOLISH SECTION

OF EXISTING FENCE SPAN ( + 34 LF)

CITY CREW TO DEMOLISH EXISTING FENCE SPAN

AND BACKILL HOLES WITH CLSM (+ 594 LF)

EXISTING UNDERGROUND ELECTRICAL

ENCLOSURE AT ELECTRICAL POINT OF

CONNECTION TO BE REMOVED AND REPLACED

BY PG&E

ELECTRICAL CONTRACTOR TO RELOCATE

EXISTING CONDUCTORS FROM EXISTING

BUILDING TO NEW SPLICE BOX SEE SHEET C-3

SCOPE OF WORK

1. DEMOLISH EXISTING MAIN ELECTRICAL SERVICE PANEL

2. DEMOLISH EXISTING CITY OWNED UTILITY POLE

3. PROVIDE AND INSTALL A NEW 200 AMP ELECTRICAL SERVICE PANEL AND RELOCATE/REROUTE EXISTING CONDUCTORS FROM EXISTING BUILDING TO NEW SPLICE BOX

4. PROVIDE AND INSTALL ELECTRICAL UNDERGROUND PER PG&E TRENCH PACKAGE

5. PROVIDE AND INSTALL ALL ELECTRICAL ACCESSORIES REQUIRED TO HAVE A COMPLETE ELECTRICAL SERVICE INSTALLATION

6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE CURRENT ELECTRICAL CODE

of

Approved by

Checked by Scale

Designed by Job No.

PREPARED BY:

DESCRIPTION DATE

REVISIONS: CITY OF WATSONVILLE, CALIFORNIA

PARKS AND COMMUNITY SERVICES

E FRONT ST. WATSONVILLE, CA 95076

RIVER PARK FENCE RELOCATION

UTILITIES PLAN

C-3

CITY TO PLACE TEMPORARY CHAIN LINK FENCE

AROUND CONSTRUCTION AREA AND ON

COMMON STAGING AREA

NOTE� REFER TO THE PG&E TRENCH PACKAGE FOR

PROPER ELECTRICAL INSTALLATION

SCOPE OF WORK

1. DEMOLISH EXISTING MAIN ELECTRICAL SERVICE PANEL

2. DEMOLISH EXISTING CITY OWNED UTILITY POLE

3. PROVIDE AND INSTALL A NEW 200 AMP ELECTRICAL SERVICE PANEL AND RELOCATE/REROUTE EXISTING CONDUCTORS FROM EXISTING BUILDING TO NEW SPLICE BOX

4. PROVIDE AND INSTALL ELECTRICAL UNDERGROUND PER PG&E TRENCH PACKAGE

5. PROVIDE AND INSTALL ALL ELECTRICAL ACCESSORIES REQUIRED TO HAVE A COMPLETE ELECTRICAL SERVICE INSTALLATION

6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE CURRENT ELECTRICAL CODE

ELECTRICAL CONTRACTOR TO

DEMOLISH EXISTING LIGHTING AND

POLE. BACK FILLHOLES WITH CLSM

ELECTRICAL CONTRACTOR TO

COORDINATE WITH PG&E AT THE

BEGINNING OF CONSTRUCTION TO

SCHEDULE PG&E CREW TO SHUT OFF

POWER TO LIGHTS BEFORE POLE AND

LIGHT REMOVAL

ELECTRICAL CONTRACTOR SHALL UNDERMINE

EXISTING CURB BOARD AND FENCE FOR

ELECTRICAL CONDUIT INSTALLATION.

CONTRACTOR MAY CUT WALL BOARD AS NEEDED

AND SHALL RESTORE IN-KING TO PRE-EXISTING

CONDITIONS

FENCING CONTRACTOR TO INSTALL STORM

DRAIN INLET FILTER FABRIC PRIOR TO

COMMENCING ANY CONSTRUCTION ACTIVITIES

ELECTRICAL CONTRACTOR TO INSTALL A

CONCRETE UNDERGROUND ELECTRICAL SPLICE

ENCLOSURE WITH A REINFORCED CONCRETE

BOLTED DOWN LID. SIZE SHALL BE APPROPRIATE

TO INDUSTRY STANDARDS AND PG&E

GREENBOOK MANUAL

ELECTRICAL CONTRACTOR TO INSTALL 2-2" DIA.

SCH. 40 PVC CONDUITS SEE DETAIL 5 ON SHEET

C-4. CONTRACTOR TOMATCH EXISTING

CONDUCTORS FROM BUILDING TO EQUIPMENT

CONTROL BOX.

ELECTRICAL CONTRACTOR TO INSTALL 1-3" DIA.

SCH. 40 PVC CONDUIT FROM ELECTRICAL TIE-IN

TO NEW PG&E METER, + 97 LF. CONTRACTOR TO

INSTALL LONG CONDUITS SWEEPS WITH 30"

MSWEEP RADIOUS WHERE APPLICABLE, CONDUIT

BEND RADIUS SHALL BE NO LESS THAN 24

INCHES. PG&E TO INSPECT TRENCH PRIOR TO

ANY BACKFILL OVER CONDUIT

ELECTRICAL CONTRACTOR SHALL UNDERMINE

EXISTING CURB BOARD AND FENCE FOR

ELECTRICAL CONDUIT INSTALLATION.

CONTRACTOR MAY CUT WALL BOARD AS NEEDED

AND SHALL RESTORE IN-KING TO PRE-EXISTING

CONDITIONS

C-4

CITY OF WATSONVILLE, CALIFORNIA

PARKS AND COMMUNITY SERVICES

Date

SHEET

of

Approved by

Checked by Scale

Designed by Job No.

NOT TO SCALE

RIVER PARK FENCE RELOCATION

PREPARED BY:

DESCRIPTION DATE

REVISIONS:

E FRONT ST. WATSONVILLE, CA 95076

DETAILS PLAN

58"

42"

15"

EXISTING

GRADE

34"- 9F EXPANDED STEEL MESH

WELDED TO FRAMES, TYP.

HINGES, SEE NOTE 6, TYP.

4"X2" RECTANGULAR

STEEL HSS WELDED TO

RIGID STEEL PIPE, TYP.

LOCKABLE LATCH

SEE NOTE 7

1 14"X1 14"X18" WELDED

ANGLE STEEL, TYP.

SIDE VIEW

ENCLOSURE FRAME

SEE NOTE 3, TYP.

GATE FRAME: 11 GA.

" X

" A500

GRADE B STEEL SQUARE HSS

TUBE, TYP.

WELDED JOINT

ENCLOSURE FRAME

SEE NOTE 3, TYP.

STEEL LEG ANGLE

SEE NOTE 4,TYP.

SEE NOTE 1

SEE NOTE 1

SEE NOTE 2

WELDED JOINT, TYP.

STEEL LEG ANGLE

SEE NOTE 4, TYP.

ENCLOSURE MOUNTS

SEE NOTE 5, TYP.

FRONT VIEW

SEE NOTE

12, TYP.

66"

60"

12" MIN.

TYP.

60" MIN

56" O.C.

70"

42"

4" MIN. TYP.

NEW LOW PROFILE 200A

ELECTRICAL PG&E

SMART METER

FRONT VIEW SIDE VIEW

5" GALV. RIGID STEEL PIPE WITH TOP CAPS

ELECTRICAL EQUIPMENT

12" SLOPE, TYP.

CONTROL

EQUIPMENT

CABINET &

CONTROL

EQUIPMENT

EXISTING

GRADE,

TYP.

1" THICK PRESSURE TREATED WOODEN

BOARD

BOARD

FASTENERS

PER LATEST

VERSION OF

PG&E

GREENBOOK

MANUAL

GALV. STEEL BOLT WITH

(2) NUTS AND WASHER,

TYP.

1- 1

2" MIN. STRUT

CHANNEL AND

REQUIRED HARDWARE,

TYP.

(4)HOLLOW METAL

SQUARE TUBE, TYP.

SEE NOTE 6

SEE NOTE

8, TYP.

3"

3"

TYP.

2"

12" MIN. IN

PG&E TRENCH

24" MIN

12"-18"

COMPETENT NATIVE SOIL

COMPACTED IN NO LESS

THAN TWO LIFTS TO 90% R.C.

6" WARNING ELECTRICAL TAPE

PER PG&E DOCUMENT 03819

RIGID SCH 40 PVC CONDUIT,

TYP.

EXISTING GRADE

COMPACTED

BEDDING SAND

REVISIONS:

PREPARED BY:

DESCRIPTION DATE

CITY OF WATSONVILLE, CALIFORNIA

PARKS AND COMMUNITY SERVICES

E FRONT ST. WATSONVILLE, CA 95076

RIVER PARK FENCE RELOCATION

TEMPORARY FENCE PLAN

Approved by

Checked by

Designed by Job No.

Scale -

- SHEET

of1

C-5

Date

LEGEND

TEMPORARY FENCE TF TF

TF TF TEMPORARY FENCE

TF TF TF TF TF TF TF

TF

TF

TF

TF

TF

TF

TF

TF

TF TF TF TF

TF

TF

TF

TF

C,TY TO ,N6TALL TEMPORARY C+A,N L,N. FENCE

OR ,N6TALL TEMPORARY ORANGE 6AFETY FENCE

ARO8ND CON6TR8CT,ON AREA ,N PAR. TO