About this file
River Park Electrical Relocation Project Summary
This is a project description document for the City of Watsonville, California, detailing electrical infrastructure work at River Park located at 100 East Front Street, Watsonville. The project scope encompasses removal of the existing electrical service and installation of new PG&E electrical service infrastructure. Additional work includes installation of electrical conduit to an existing building and minor concrete work associated with the relocation. The project represents a complete electrical service upgrade and relocation effort at the municipal park facility.
The document provides general project overview information establishing the scope of work and location but does not contain detailed specifications regarding project timeline, bidding deadlines, site visit requirements, pre-bid meetings, contract award dates, pricing terms, or contract duration in the materials presented. Interested contractors should refer to the associated state and local contract opportunity listing for complete bidding requirements, submission deadlines, and project specifications necessary to prepare and submit proposals for this electrical relocation work.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| River_Park_Electrical_Relocation.pdf | ||
| PG&E_Trench_Packet.pdf | ||
| Payment_Bond_QB.pdf | ||
| Performance_Bond_QB.pdf | ||
| Sample_Insurance_Endorsement.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Date
SHEET
of
Approved by
Checked by Scale
Designed by Job No.
PREPARED BY:
DESCRIPTION DATE
REVISIONS: CITY OF WATSONVILLE, CALIFORNIA
PARKS AND COMMUNITY SERVICES
E FRONT ST. WATSONVILLE, CA 95076
RIVER PARK FENCE RELOCATION
1 5 C-1
NEW FENCE PLAN
CITY TO PLACE TEMPORARY CHAIN LINK FENCE
AROUND CONSTRUCTION AREA AND ON
COMMON STAGING AREA
FENCING CONTRACTOR TO INSTALL
NEW 8 FT TALL SECURITY FENCE AT
SAME LOCATION AS EXISTING
CHAIN LINK FENCE SPAN BETWEEN
COMMUNITY GARDEN AND PARK
SCOPE OF WORK
1. DEMOLISH EXISTING MAIN ELECTRICAL SERVICE PANEL
2. DEMOLISH EXISTING CITY OWNED UTILITY POLE
3. PROVIDE AND INSTALL A NEW 200 AMP ELECTRICAL SERVICE PANEL AND RELOCATE/REROUTE EXISTING CONDUCTORS FROM EXISTING BUILDING TO NEW SPLICE BOX
4. PROVIDE AND INSTALL ELECTRICAL UNDERGROUND PER PG&E TRENCH PACKAGE
5. PROVIDE AND INSTALL ALL ELECTRICAL ACCESSORIES REQUIRED TO HAVE A COMPLETE ELECTRICAL SERVICE INSTALLATION
6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE CURRENT ELECTRICAL CODE
FENCING CONTRACTOR TO INSTALL NEW 8 FT
TALL FENCE PRIOR TO DEMOLISH EXISTING FENCE
TO MAINTAIN A SECURE PLAY AREA DURING
CONSTRUCTION
ELECTRICAL CONTRACTOR TO
INSTALL NEW ELECTRICAL PANEL
BOARD. SEE SHEET C-3
FENCING CONTRACTOR TO HAND/VACC EXCAVATE
HOLES WITHIN TREE DRIP LINES. ADJUST POST
LOCATIONS TO MISS ROOTS LARGER THAN 2" DIA.
CLEANLY CUT ROOTS 2" DIA. OR SMALLER WITH
LOPPERS
FENCING CONTRACTOR SHALL NOT INSTALL DOWELS
INTO EXISTING CONCRETE FOUNDATIONS
FENCING CONTRACTOR TO INSTALL STORM DRAIN
INLET FILTER FABRIC PRIOR TO COMMENCING ANY
CONSTRUCTION ACTIVITIES
FENCING CONTRACTOR TO PROVIDE POSITIVE
DRAINAGE AWAY FROM CONCRETE SLAB TO ALLOW
RUNOFF TO FLOW PER EXISTING DRAINAGE
CONDITIONS
FENCING CONTRACTOR TO INSTALL NEW FENCE
FOUNDATIONS STAGGERED FROM EXISTING FENCE
FOUNDATIONS AND PROVIDE SPACING BETWEEN
EXISTING FOUNDATION AND IMPROVEMENTS
of
Approved by
Checked by Scale
Designed by Job No.
PREPARED BY:
DESCRIPTION DATE
REVISIONS: CITY OF WATSONVILLE, CALIFORNIA
PARKS AND COMMUNITY SERVICES
E FRONT ST. WATSONVILLE, CA 95076
RIVER PARK FENCE RELOCATION
2 5 C-2
DEMOLITION PLAN
CITY CREW TO DEMOLISH SECTION OF EXISTING
CONCRETE BASE UP TO NEW FENCE + 250 SF.
CITY CREW TO DEMOLISH SECTION
OF EXISTING FENCE SPAN ( + 34 LF)
CITY CREW TO DEMOLISH EXISTING FENCE SPAN
AND BACKILL HOLES WITH CLSM (+ 594 LF)
EXISTING UNDERGROUND ELECTRICAL
ENCLOSURE AT ELECTRICAL POINT OF
CONNECTION TO BE REMOVED AND REPLACED
BY PG&E
ELECTRICAL CONTRACTOR TO RELOCATE
EXISTING CONDUCTORS FROM EXISTING
BUILDING TO NEW SPLICE BOX SEE SHEET C-3
SCOPE OF WORK
1. DEMOLISH EXISTING MAIN ELECTRICAL SERVICE PANEL
2. DEMOLISH EXISTING CITY OWNED UTILITY POLE
3. PROVIDE AND INSTALL A NEW 200 AMP ELECTRICAL SERVICE PANEL AND RELOCATE/REROUTE EXISTING CONDUCTORS FROM EXISTING BUILDING TO NEW SPLICE BOX
4. PROVIDE AND INSTALL ELECTRICAL UNDERGROUND PER PG&E TRENCH PACKAGE
5. PROVIDE AND INSTALL ALL ELECTRICAL ACCESSORIES REQUIRED TO HAVE A COMPLETE ELECTRICAL SERVICE INSTALLATION
6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE CURRENT ELECTRICAL CODE
of
Approved by
Checked by Scale
Designed by Job No.
PREPARED BY:
DESCRIPTION DATE
REVISIONS: CITY OF WATSONVILLE, CALIFORNIA
PARKS AND COMMUNITY SERVICES
E FRONT ST. WATSONVILLE, CA 95076
RIVER PARK FENCE RELOCATION
UTILITIES PLAN
C-3
CITY TO PLACE TEMPORARY CHAIN LINK FENCE
AROUND CONSTRUCTION AREA AND ON
COMMON STAGING AREA
NOTE� REFER TO THE PG&E TRENCH PACKAGE FOR
PROPER ELECTRICAL INSTALLATION
SCOPE OF WORK
1. DEMOLISH EXISTING MAIN ELECTRICAL SERVICE PANEL
2. DEMOLISH EXISTING CITY OWNED UTILITY POLE
3. PROVIDE AND INSTALL A NEW 200 AMP ELECTRICAL SERVICE PANEL AND RELOCATE/REROUTE EXISTING CONDUCTORS FROM EXISTING BUILDING TO NEW SPLICE BOX
4. PROVIDE AND INSTALL ELECTRICAL UNDERGROUND PER PG&E TRENCH PACKAGE
5. PROVIDE AND INSTALL ALL ELECTRICAL ACCESSORIES REQUIRED TO HAVE A COMPLETE ELECTRICAL SERVICE INSTALLATION
6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE CURRENT ELECTRICAL CODE
ELECTRICAL CONTRACTOR TO
DEMOLISH EXISTING LIGHTING AND
POLE. BACK FILLHOLES WITH CLSM
ELECTRICAL CONTRACTOR TO
COORDINATE WITH PG&E AT THE
BEGINNING OF CONSTRUCTION TO
SCHEDULE PG&E CREW TO SHUT OFF
POWER TO LIGHTS BEFORE POLE AND
LIGHT REMOVAL
ELECTRICAL CONTRACTOR SHALL UNDERMINE
EXISTING CURB BOARD AND FENCE FOR
ELECTRICAL CONDUIT INSTALLATION.
CONTRACTOR MAY CUT WALL BOARD AS NEEDED
AND SHALL RESTORE IN-KING TO PRE-EXISTING
CONDITIONS
FENCING CONTRACTOR TO INSTALL STORM
DRAIN INLET FILTER FABRIC PRIOR TO
COMMENCING ANY CONSTRUCTION ACTIVITIES
ELECTRICAL CONTRACTOR TO INSTALL A
CONCRETE UNDERGROUND ELECTRICAL SPLICE
ENCLOSURE WITH A REINFORCED CONCRETE
BOLTED DOWN LID. SIZE SHALL BE APPROPRIATE
TO INDUSTRY STANDARDS AND PG&E
GREENBOOK MANUAL
ELECTRICAL CONTRACTOR TO INSTALL 2-2" DIA.
SCH. 40 PVC CONDUITS SEE DETAIL 5 ON SHEET
C-4. CONTRACTOR TOMATCH EXISTING
CONDUCTORS FROM BUILDING TO EQUIPMENT
CONTROL BOX.
ELECTRICAL CONTRACTOR TO INSTALL 1-3" DIA.
SCH. 40 PVC CONDUIT FROM ELECTRICAL TIE-IN
TO NEW PG&E METER, + 97 LF. CONTRACTOR TO
INSTALL LONG CONDUITS SWEEPS WITH 30"
MSWEEP RADIOUS WHERE APPLICABLE, CONDUIT
BEND RADIUS SHALL BE NO LESS THAN 24
INCHES. PG&E TO INSPECT TRENCH PRIOR TO
ANY BACKFILL OVER CONDUIT
ELECTRICAL CONTRACTOR SHALL UNDERMINE
EXISTING CURB BOARD AND FENCE FOR
ELECTRICAL CONDUIT INSTALLATION.
CONTRACTOR MAY CUT WALL BOARD AS NEEDED
AND SHALL RESTORE IN-KING TO PRE-EXISTING
CONDITIONS
C-4
CITY OF WATSONVILLE, CALIFORNIA
PARKS AND COMMUNITY SERVICES
Date
SHEET
of
Approved by
Checked by Scale
Designed by Job No.
NOT TO SCALE
RIVER PARK FENCE RELOCATION
PREPARED BY:
DESCRIPTION DATE
REVISIONS:
E FRONT ST. WATSONVILLE, CA 95076
DETAILS PLAN
58"
42"
15"
EXISTING
GRADE
34"- 9F EXPANDED STEEL MESH
WELDED TO FRAMES, TYP.
HINGES, SEE NOTE 6, TYP.
4"X2" RECTANGULAR
STEEL HSS WELDED TO
RIGID STEEL PIPE, TYP.
LOCKABLE LATCH
SEE NOTE 7
1 14"X1 14"X18" WELDED
ANGLE STEEL, TYP.
SIDE VIEW
ENCLOSURE FRAME
SEE NOTE 3, TYP.
GATE FRAME: 11 GA.
" X
" A500
GRADE B STEEL SQUARE HSS
TUBE, TYP.
WELDED JOINT
ENCLOSURE FRAME
SEE NOTE 3, TYP.
STEEL LEG ANGLE
SEE NOTE 4,TYP.
SEE NOTE 1
SEE NOTE 1
SEE NOTE 2
WELDED JOINT, TYP.
STEEL LEG ANGLE
SEE NOTE 4, TYP.
ENCLOSURE MOUNTS
SEE NOTE 5, TYP.
FRONT VIEW
SEE NOTE
12, TYP.
66"
60"
12" MIN.
TYP.
60" MIN
56" O.C.
70"
42"
4" MIN. TYP.
NEW LOW PROFILE 200A
ELECTRICAL PG&E
SMART METER
FRONT VIEW SIDE VIEW
5" GALV. RIGID STEEL PIPE WITH TOP CAPS
ELECTRICAL EQUIPMENT
12" SLOPE, TYP.
CONTROL
EQUIPMENT
CABINET &
CONTROL
EQUIPMENT
EXISTING
GRADE,
TYP.
1" THICK PRESSURE TREATED WOODEN
BOARD
BOARD
FASTENERS
PER LATEST
VERSION OF
PG&E
GREENBOOK
MANUAL
GALV. STEEL BOLT WITH
(2) NUTS AND WASHER,
TYP.
1- 1
2" MIN. STRUT
CHANNEL AND
REQUIRED HARDWARE,
TYP.
(4)HOLLOW METAL
SQUARE TUBE, TYP.
SEE NOTE 6
SEE NOTE
8, TYP.
3"
3"
TYP.
2"
12" MIN. IN
PG&E TRENCH
24" MIN
12"-18"
COMPETENT NATIVE SOIL
COMPACTED IN NO LESS
THAN TWO LIFTS TO 90% R.C.
6" WARNING ELECTRICAL TAPE
PER PG&E DOCUMENT 03819
RIGID SCH 40 PVC CONDUIT,
TYP.
EXISTING GRADE
COMPACTED
BEDDING SAND
REVISIONS:
PREPARED BY:
DESCRIPTION DATE
CITY OF WATSONVILLE, CALIFORNIA
PARKS AND COMMUNITY SERVICES
E FRONT ST. WATSONVILLE, CA 95076
RIVER PARK FENCE RELOCATION
TEMPORARY FENCE PLAN
Approved by
Checked by
Designed by Job No.
Scale -
- SHEET
of1
C-5
Date
LEGEND
TEMPORARY FENCE TF TF
TF TF TEMPORARY FENCE
TF TF TF TF TF TF TF
TF
TF
TF
TF
TF
TF
TF
TF
TF TF TF TF
TF
TF
TF
TF
C,TY TO ,N6TALL TEMPORARY C+A,N L,N. FENCE
OR ,N6TALL TEMPORARY ORANGE 6AFETY FENCE
ARO8ND CON6TR8CT,ON AREA ,N PAR. TO
PRE9ENT PEDE6TR,AN6 FROM :AL.,NG ,NTO
CON6TR8CT,ON =ONE
| Sheets and Views |
| Layout1 |
| C2.pdf |
| Sheets and Views |
| Layout1 |
| C3.pdf |
| Sheets and Views |
| Layout1 |
| C4.pdf |
| Sheets and Views |
| Layout1 |
| C5.pdf |
| Sheets and Views |
| Layout1 |
File details come from the government source that posted it. Updated .