RFQ Southwestern Maintenance - rvsd LRM 12.14.21 (1).docx

DOCX document 757 KB Posted

Attached to
OSR SOUTHWESTERN MAINTENANCE OPEN-END
Solicitation number
ARFQ 0313 DEP2200000044 1
Issued by
Preston County, West Virginia

About this file

This is a Request for Quotation (RFQ) issued by the West Virginia Department of Environmental Protection for maintenance services in the southwestern region of the state. The solicitation seeks bids to establish an open-end contract providing all equipment, labor, materials, and services necessary for maintenance projects across ten counties: Putnam, Clay, Boone, Mingo, Cabell, Kanawha, Logan, Lincoln, Mason, and Wayne Counties, plus the portion of Nicholas County west of US Route 19. The contract requires vendors to supply an extensive array of heavy equipment including various dozers (D-8N, D-6H, D-3G LGP, D-5G LGP), loaders, excavators, pumps, and specialized machinery such as vibratory rollers and graders. Additionally, vendors must provide materials including various types of stone, pipe (PVC and HDPE), seed mixtures for revegetation, fertilizers, lime, mulch, geotextiles, and erosion control products. Individual work directives will not exceed $25,000, and vendors must acknowledge receipt of work directives and obtain a signed Notice to Proceed before commencing work. The document does not specify a pre-bid meeting, response deadline, or contract award date; however, it was revised on October 27, 2014, and dated December 14, 2021.

Pricing shall be submitted through the wvOASIS system on a unit price basis for all specified items and services. The vendor is responsible for all mileage and travel costs, which should be incorporated into flat fees or hourly rates rather than billed separately. Mobilization and demobilization costs are incidental to hourly rates for most equipment items. All material bid items are priced as delivered to the site with installation costs paid under labor and machine hours unless otherwise specified. A one-year warranty period commences on the final date of service, with consideration given to unforeseen conditions during that period. The contract requires vendors to designate a primary contract manager available during normal business hours and maintain compliance with all applicable laws, rules, and ordinances. The vendor must demonstrate the ability to supply multiple pieces of equipment and materials concurrently or consecutively as requested and shall provide qualified operators with each piece of equipment as part of the hourly rate.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SPECIFICATIONS

1. PURPOSE AND SCOPE: The West Virginia Department of Environmental Protection is soliciting bids to establish an open-end contract for maintenance services to provide all equipment, labor, materials, and other necessary services for the southwestern region of West Virginia.

2. DEFINITIONS: The terms listed below shall have the meanings assigned to them below. Additional definitions can be found in section 2 of the Standard Specifications for Construction and Reclamation – Time and Materials Contract.

2.1 “Contract Services” means supplying all labor, materials and other necessary services for maintenance of projects in the southwestern region of the West Virginia Department of Environmental Protection/Office of Special Reclamation. Counties included in this defined region being: Putnam, Clay, Boone, Mingo, Cabell, Kanawha, Logan, Lincoln, Mason, and Wayne Counties. Also, that portion of Nicholas county laying to the west of US Route 19.

2.2 “Pricing Page” means the schedule of prices, estimated order quantity, and totals contained in wvOASIS and used to evaluate the Solicitation responses.

3. PRE-BID MEETING:

A pre-bid meeting will not be held.

4. MANDATORY REQUIREMENTS:

4.1 Contract services will be ordered by the Assistant Director of the Office of Special Reclamation or his representative by issuance of a Work Directive, which shall include the name and permit number for the site, location and the cost estimate (estimated quantity of work to be done, specified equipment, and materials to be used.)

4.2 The vendor shall acknowledge receipt and acceptance by signing, dating and forwarding back to the Director or his representative, the Work Directive for the project requested. The cost estimate shall be in accordance with the unit prices provided in the solicitation response.

4.3 WV DEP will issue a Notice to Proceed which will specify cost of project and starting and ending dates. The vendor shall not begin work until a signed Notice to Proceed has been issued by the WVDEP.

4.4 Project costs should not exceed the amount of the Work Directive. Any changes pertaining to the Work Directive shall require written justification and approval form WVDEP.

4.5 Individual Work Directives will not exceed $25,000.00.

4.6 It shall be the contractor’s responsibility to check and locate all utilities within the work area to provide and maintain a safe working area in addition to preventing damage to the utilities.

4.7 Vendor must have the ability to supply all specified equipment, labor, and materials upon request of the West Virginia Department of Environmental Protection/Office of Special Reclamation.

4.8 Vendor must have the ability to supply all specified equipment, labor, and materials on multiple individual projects either concurrently or consecutively if requested by the West Virginia Department of Environmental Protection/Office of Special Reclamation.

4.9 All specified equipment shall be supplied with a qualified operator by the vendor as part of the hourly rate for each piece of specified equipment.

4.10 Mandatory Contract Services Requirements and Deliverables: Contract Services must meet or exceed the mandatory requirements listed below.

4.10.1 Crawler Dozer-Caterpillar D-8N or equivalent

4.10.1.1 Crawler Dozer-Caterpillar D-8N or equivalent must have 285 minimum flywheel horsepower, equipped with a U-Type Dozer Blade.

4.10.2 Crawler Dozer-Caterpillar D-6H or equivalent.

4.10.2.1 Crawler Dozer-Caterpillar D-6H or equivalent must have 165 minimum flywheel horsepower, equipped with a straight or angle- type dozer blade.

4.10.3 Crawler Dozer-Caterpillar D-3G LGP or equivalent

4.10.3.1 Crawler Dozer-Caterpillar D-3G LGP or equivalent must have 52 minimum flywheel horsepower, equipped with a straight or angle-type dozer blade.

4.10.4 Crawler Dozer-Caterpillar D-5G LGP or equivalent.

4.10.4.1 Crawler Dozer-Caterpillar D-5G LGP or equivalent must have 67 minimum flywheel horsepower, equipped with a straight or angle-type dozer blade.

4.10.5 Crawler Loader-Caterpillar 931C or equivalent.

4.10.5.1 Crawler Loader-Caterpillar 931C or equivalent must have 67 minimum flywheel horsepower with standard 1.05 yd. bucket.

4.10.6 Backhoe Loader, Rubber-Tired or equivalent.

4.10.6.1 Backhoe Loader, Rubber-Tired must have 60 minimum flywheel horsepower loader bucket capacity-minimum 1 cubic yard; backhoe bucket size-minimum 6.0 cubic feet.

4.10.7 Hydraulic Excavator-Backhoe-Caterpillar 314 or equivalent.

4.10.7.1 Hydraulic Excavator-Backhoe-Caterpillar 314 or equivalent must have 90 minimum flywheel horsepower, equipped with standard bucket.

4.10.8 Hydraulic Excavator-Backhoe-Caterpillar 318 or equivalent.

4.10.8.1 Hydraulic Excavator-Backhoe-Caterpillar 318 or equivalent must have 115 minimum flywheel horsepower, equipped with standard bucket.

4.10.9 Hydraulic Excavator-Backhoe-Caterpillar 325 or equivalent.

4.10.9.1 Hydraulic Excavator-Backhoe-Caterpillar 325 or equivalent must have 173 minimum flywheel horsepower, equipped with standard bucket.

4.10.10 Hydraulic Excavator-Backhoe Long Reach, John Deere 790ELC or equivalent.

4.10.10.1 Hydraulic Excavator-Backhoe Long Reach, John Deere 790 or equivalent must have 155 minimum flywheel horsepower, maximum reach at ground level of 59 feet minimum, equipped with standard bucket.

4.10.11 Skid steer loader Bobcat T190 or equivalent.

4.10.11.1 Skid steer loader Bobcat T190 or equivalent must have 66 minimum horsepower and hydraulic output of 16.96 gpm to 26.40 gpm equipped with 72-inch rotary cutter capable of cutting up to 3-inch diameter material.

4.10.11.2 Mobilization and Demobilization shall be incidental to the hourly rate.

4.10.12 Skid steer loader Bobcat T190 or equivalent.

4.10.12.1 Skid steer loader Bobcat T190 or equivalent must have 66 minimum horsepower and hydraulic output of 16.96 gpm to 26.40 gpm equipped with 74-inch utility bucket.

4.10.12.2 Mobilization and Demobilization shall be incidental to the hourly rate.

4.10.13 Articulated Truck – Caterpillar D250E or equivalent.

4.10.13.1 Articulated Truck – Caterpillar D250E or equivalent must have 260 minimum flywheel horsepower with minimum 25-ton capacity.

4.10.14 Truck, Tandem Axle.

4.10.14.1 Truck, Tandem Axle must have rear dump, 8 to 10 cubic yard capacity, 35,000 GVW minimum, 210 flywheel horsepower equipped with a sealed tailgate.

4.10.14.2 Mobilization and Demobilization shall be incidental to the hourly rate.

4.10.15 Tractor with low boy.

4.10.15.1 Tractor with low boy must be licensed for 110,000 pounds. This item is intended for mobilization and demobilization of equipment. To include all permits and fees necessary for legal transportation of equipment. All other costs including break-down and put-together costs of equipment will be incidental to the other items – per hour. Hourly Rate will be paid one (1) time in and one time out while the truck is loaded for each machine used on the project.

4.10.16 Single Smooth Drum Vibratory Roller.

4.10.16.1 Single Smooth Drum Vibratory Roller shall be a Bomag BW145D-40 or equivalent with a minimum centrifugal force of 22,000 pounds.

4.10.17 Mini Hydraulic Excavator equipped with standard bucket.

4.10.17.1 Mini Hydraulic Excavator equipped with standard bucket shall be a Cat 305 CR or equivalent with a minimum 39 flywheel horsepower.

4.10.17.2 Mobilization and Demobilization shall be incidental to the hourly rate.

4.10.18 Mini Hydraulic Excavator equipped with brush mower/mulcher.

4.10.18.1 Mini Hydraulic Excavator equipped with brush mower/mulcher shall be a Cat 305 CR or equivalent with a minimum 39 flywheel horsepower and minimum auxiliary hydraulic flow of 15 gpm. It shall be equipped with a Rockhound 30EX brush mower or equivalent, featuring a flail style cutter drum.

4.10.18.2 Mobilization and Demobilization shall be incidental to the hourly rate.

4.10.19 Motor Grader.

4.10.19.1 Motor Grader shall be a Cat 120M2 or equivalent with a minimum 145 flywheel horsepower.

4.10.20 Pressure Washer.

4.10.20.1 Pressure Washer shall be able to produce a maximum flow rate of a minimum 2.5 gpm and produce maximum pressure of minimum 3,300 psi.

4.10.20.2 Pressure Washer shall be provided with a minimum 300-gallon portable water tank, plumbed to provide water supply for the pressure washer when requested.

4.10.20.3 Pressure washer shall be provided with a jetter drain cleaning kit, including 150 foot of jetter hose on projects when requested.

4.10.20.4 Mobilization and Demobilization shall be incidental to the hourly rate.

4.10.21 Vibratory Rammer.

4.10.21.1 Vibratory Rammer shall be a Wacker Neuson BS50-4S or equivalent.

4.10.21.2 Mobilization and Demobilization shall be incidental to the hourly rate.

4.10.22 Seed mixture for revegetation.

4.10.22.1 Seed mixture for revegetation must be applied after seed bed preparation and consist of the following:

Vegetative SpeciesRate/Acre
Birdsfoot Trefoil@ 15 lbs/acre
Annual Ryegrass@ 15 lbs/acre
Orchard Grass@ 15 lbs/acre
Red Clover@ 10 lbs/acre
Foxtail Millet@ 12 lbs/acre

or Winter Wheat @ 20 lbs/acre

4.10.22.2 Herbaceous legume must be treated with the appropriate bacterium before seeding. On areas that are steeply sloping (steeper than 1.7:1), slide prone or drainage conveyance structures substitute Crown Vetch (Coronilla Varia) at 20 lbs/acre for Birdsfoot Trefoil.

4.10.22.3 Use Annual Ryegrass only in mixtures seeded after August 1 and before May 1.

4.10.22.4 Use only certified “blue tag” seed. Seed-rate suggested is for pure live seed (PLS) in lbs/acre.

4.10.22.5 Price per acre shall include delivery to the site and application.

4.10.23 Seed mixture for vegetative enhancement.

4.10.23.1 Seed mixture for vegetative enhancement must be applied for vegetation enhancement and consist of the following:

Vegetative SpeciesRate/Acre
Birdsfoot Trefoil@ 5 lbs/acre
Orchard Grass@ 5 lbs/acre
Red Clover@ 5 lbs/acre

4.10.23.2 Herbaceous legume must be treated with the appropriate bacterium before seeding. On areas that are steeply sloping (steeper than 1.7:1), slide prone or drainage conveyance structures

REQUEST FOR QUOTATION

SOUTHWESTERN OPEN-END MAINTENANCE

Revised 10/27/2014 substitute Crown Vetch (Coronilla Varia) at 20 lbs. /acre for Birdsfoot Trefoil.

4.10.23.3 Use only certified “blue tag” seed. Seed-rate suggested is for pure live seed (PLS) in lbs. /acre.

4.10.23.4 Price per acre shall include delivery to the site and application.

4.10.24 Additional seed mixture for woodland post mining land use.

4.10.24.1 Additional seed mixture for woodland post mining land use must be applied for woodland post-mining land use projects and consist of the following:

Vegetative SpeciesRate/Acre
Black Locust@ 3 lbs/acre

4.10.24.2 Use only certified “blue tag” seed. Seed-rate suggested is for pure live seed (PLS) in lbs/acre.

4.10.24.3 Price per acre shall include delivery to the site and application.

4.10.25 Agriculture Lime

4.10.25.1 Agriculture Lime must be a minimum of 85% CaCO3.

4.10.25.2 Price per ton shall include delivery to the site and application.

4.10.26 Fertilizer 10-20-10.

4.10.26.1 Price per ton shall include delivery to the site and application.

4.10.27 Fertilizer 18-46-0.

4.10.27.1 Price per ton shall include delivery to the site and application.

4.10.28 Mulch, Cellulose Fiber

4.10.28.1 Mulch, Cellulose Fiber shall be Terra-Mulch Cellulose Fiber or equivalent.

4.10.28.2 Price per ton shall include delivery to the site and application.

4.10.29 Mulch, Hay or Straw

4.10.29.1 Price per ton shall include delivery to the site and application.

4.10.30 Stone - 2-inch sandstone, delivered to site.

4.10.31 Stone - shot sandstone, delivered to site.

4.10.32 Stone - gabion sandstone 4-inch x 8 inch, delivered to site.

4.10.33 Stone - shot limestone, delivered to site.

4.10.34 Stone - Type 3 – Rip-Rap limestone 36-inch x 6 inch, delivered to site.

4.10.35 Stone - Type 2 – Rip-Rap limestone 30-inch x 6 inch, delivered to site.

4.10.36 Stone - Type 1 – Rip-Rap limestone 12-inch x 3 inch, delivered to site.

4.10.37 Stone - gabion limestone 4-inch x 8 inch, delivered to site.

4.10.38 Stone - limestone 2 inches, delivered to site.

4.10.39 Stone - No. 57 limestone, delivered to site.

4.10.40 Stone - crusher run, limestone, delivered to site.

4.10.41 Limestone Sand

4.10.41.1 Limestone sand must be a minimum of 92% CaCO3 with particle size of 5% maximum retained on a #10 mesh screen, 15% maximum retained on a #20 mesh screen, 30% maximum passing a #60 screen, delivered to site.

4.10.42 Limestone Sand

4.10.42.1 Limestone sand must be a minimum of 97% CaCO3 16 mesh (Glass Factory Limestone Sand) with particle size of 0% retained on a #12 mesh screen, 20% maximum retained on a #20 mesh screen, 20% maximum passing a #70 screen, delivered to site.

4.10.43 Pipe - 12-inch schedule 40 P.V.C.

4.10.43.1 Pipe - 12-inch schedule 40 P.V.C. or equivalent shall be provided with a bell end for assembly.

4.10.44 Pipe - 12-inch 45° schedule 40 P.V.C.

4.10.45 Pipe - 12-inch 90° schedule 40 P.V.C.

4.10.46 Pipe - 12-inch cap schedule 40 P.V.C.

4.10.47 Pipe - Tee, 12-inch schedule 40 P.V.C.

4.10.48 Pipe - 6-inch solid schedule 40 pipe P.V.C.

4.10.49 Pipe - 6-inch perforated schedule 40 pipe P.V.C.

4.10.50 Pipe - 6 inch “T” schedule 40 P.V.C.

4.10.51 Pipe - 6-inch screw on cap schedule 40 P.V.C.

4.10.52 Pipe - 6-inch solid end cap schedule 40 P.V.C.

4.10.53 Pipe - 6-inch 45° schedule 40 P.V.C.

4.10.54 Pipe - 6-inch connector schedule 40 P.V.C

4.10.55 Pipe - 6-inch 90° schedule 40 P.V.C.

4.10.56 Pipe - 6 inch 22½° schedule 40 P.V.C.

4.10.57 18-inch HDPE Pipe

4.10.57.1 18-inch HDPE shall be DR17 fusible HDPE pipe. Cost of pipe shall include the use of a fusing machine when required for assembly.

4.10.58 12-inch HDPE Pipe

4.10.58.1 12-inch HDPE shall be DR17 fusible HDPE pipe. Cost of pipe shall include the use of a fusing machine when required for assembly.

4.10.59 6-inch HDPE Pipe

4.10.59.1 6-inch HDPE shall be DR17 fusible HDPE pipe. Cost of pipe shall include the use of a fusing machine when required for assembly.

4.10.60 4-inch HDPE Pipe

4.10.60.1 4-inch HDPE shall be DR17 fusible HDPE pipe. Cost of pipe shall include the use of a fusing machine when required for assembly.

4.10.61 18-inch HDPE Pipe Fittings

4.10.61.1 18-inch HDPE pipe fittings shall be DR17 fusible HDPE pipe fittings of any of the following types: Tees, Wyes, 45°s, and 90°s. Cost of fittings shall include the use of a fusing machine when required for assembly.

4.10.62 12-inch HDPE pipe fittings

4.10.62.1 12-inch HDPE pipe fittings shall be DR17 fusible HDPE pipe fittings of any of the following types: Tees, Wyes, 45°s, and 90°s. Cost of fittings shall include the use of a fusing machine when required for assembly.

4.10.63 6-inch HDPE Pipe Fittings

4.10.63.1 4.6 inch HDPE pipe fittings shall be DR17 fusible HDPE pipe fittings of any of the following types: Tees, Wyes, 45°s, 90°s, HDPE to stainless steel male threaded transition, cam and groove hose fitting with lockable dust cap. Cost of fittings shall include the use of a fusing machine when required for assembly.

4.10.64 4-inch HDPE Pipe Fittings

4.10.64.1 4-inch HDPE pipe fittings shall be DR17 fusible HDPE pipe fittings of any of the following types: Tees, Wyes, 45°s, and 90°s. Cost of fittings shall include the use of a fusing machine when required for assembly.

4.10.65 6-inch Stainless Steel Knife Valves

4.10.65.1 6-inch Stainless Steel Knife Valves shall be “316 Grade” stainless steel and shall be equipped with a handwheel, nitrile gaskets and all stainless-steel mounting hardware.

4.10.65.2 All mounting hardware shall have a waterproof “anti-seize” lubricant applied during the installation thereof.

4.10.66 4-inch Stainless Steel Knife Valves

4.10.66.1 4-inch Stainless Steel Knife Valves shall be “316 Grade” stainless steel and shall be equipped with a handwheel, nitrile gaskets and all stainless-steel mounting hardware.

4.10.66.2 All mounting hardware shall have a waterproof “anti-seize” lubricant applied during the installation thereof.

4.10.67 10-foot Farm Gate

4.10.67.1 Farm Gate shall be 10-foot-long, tube gate with 16-gauge tubing of 2-inch diameter. Price of gate shall include all hardware needed for installation, including two (2) 6 inch by 8-foot CCA pressure treated wood posts.

4.10.67.2 Gate price shall include delivery to site.

4.10.67.3 Installation shall be paid under equipment and labor hours.

4.10.68 18-foot Pipe Gate

4.10.68.1 18-foot Pipe Gate shall be fabricated in accordance to the attached drawing (Attachment B) and shall be thoroughly cleaned, primed and painted green, utilizing Carboline brand Rustbond FC primer and two to three coats of Carboline brand Carbothane 133 HB paint, or approved equivalents.

4.10.68.2 Gate price shall include delivery to site.

4.10.68.3 Installation shall be paid under equipment and labor hours.

4.10.69 Bentonite Sealer

4.10.69.1 Bentonite Sealer shall be sodium bentonite with no additives, in powder or granular form upon request.

4.10.70 12-inch HI-Q Dual Walled Corrugated Culvert or equivalent

4.10.70.1 HI-Q Dual Walled Corrugated Culvert or equivalent must be 20-foot section.

4.10.70.2 Price per each shall include delivery to site.

4.10.71 18-inch HI-Q Dual Walled Corrugated Culvert or equivalent

4.10.71.1 HI-Q Dual Walled Corrugated Culvert or equivalent must be 20-foot section.

4.10.71.2 Price per each shall include delivery to site.

4.10.72 24-inch HI-Q Dual Walled Corrugated Culvert or equivalent

4.10.72.1 HI-Q Dual Walled Corrugated Culvert or equivalent must be 20-foot section.

4.10.72.2 Price per each shall include delivery to site.

4.10.73 Trailer Mounted 6-inch Water Pump.

4.10.73.1 Water pump must be 6-inch diameter input and output gas and/or diesel powered with trailer mounting

4.10.73.2 Mobilization and Demobilization shall be incidental to the hourly rate.

4.10.73.3 Set up and breakdown shall be incidental to the hourly rate.

4.10.73.4 Pump must be capable of producing a minimum 75% of the manufacturer’s rated output (gpm) and be operated at the pump motors rated maximum continuous performance for the duration of pumping.

4.10.73.5 Vendor shall also provide a minimum of 100 feet of suction line, a minimum of 150 feet of discharge line and a bolt on float for each suction line upon request. Vendor shall provide all fittings and connections necessary for use of pumps in manner requested by agency.

4.10.74 Trailer Mounted 6-inch Trash Pump.

4.10.74.1 Trash pump must be 6-inch diameter input and output gas and/or diesel powered with trailer mounting and be able to pump up to 3-inch solids.

4.10.74.2 Mobilization and Demobilization shall be incidental to the hourly rate.

4.10.74.3 Set up and breakdown shall be incidental to the hourly rate.

4.10.74.4 Pump must be capable of producing 75% of the manufacturer’s rated output (gpm) and be operated at the pump motors rated maximum continuous performance for the duration of pumping.

4.10.74.5 Vendor shall also provide a minimum of 100 feet of suction line, a minimum of 150 feet of discharge line and a bolt on float for each suction line upon request. Vendor shall provide all fittings and connections necessary for use of pumps in manner requested by agency.

4.10.75 Trailer Mounted Trash/Sludge High Head/High Volume.

4.10.75.1 Trailer mounted trash/sludge high head/high volume pump (Godwin HL5M Dri–Prime) or equivalent must be 6-inch diameter input and output gas and/or diesel powered with trailer mounting and be able to pump up to 3-inch solids

4.10.75.2 Mobilization and Demobilization shall be incidental to the hourly rate.

4.10.75.3 Set up and breakdown shall be incidental to the hourly rate.

4.10.75.4 Pump must be capable of producing a minimum 75% of the manufacturer’s rated output (gpm) and be operated at the pump motors rated maximum continuous performance for the duration of pumping.

4.10.75.5 Vendor shall also provide a minimum of 100 feet of suction line, a minimum of 150 feet of discharge line and a bolt on float for each suction line upon request. Vendor shall provide all fittings and connections necessary for use of pumps in manner requested by agency.

4.10.76 4-inch Trash Water Pump.

4.10.76.1 Trash water pump must be 4-inch diameter input and output gas and/or diesel powered.

4.10.76.2 Mobilization and Demobilization shall be incidental to the hourly rate.

4.10.76.3 Set up and breakdown shall be incidental to the hourly rate.

4.10.76.4 Pump must be capable of producing 75% of the manufacturer’s rated output (gpm) and be operated at the pump motors rated maximum continuous performance for the duration of pumping.

4.10.76.5 Vendor shall also provide a minimum of 100 feet of suction line, a minimum of 150 feet of discharge line and a bolt on float for each suction line upon request. Vendor shall provide all fittings and connections necessary for use of pumps in manner requested by agency.

4.10.77 3-inch Trash Water Pump.

4.10.77.1 Trash water pump must be 3-inch diameter input and output gas and/or diesel powered.

4.10.77.2 Mobilization and Demobilization shall be incidental to the hourly rate.

4.10.77.3 Set up and breakdown shall be incidental to the hourly rate.

4.10.77.4 Pump must be capable of producing a minimum 75% of the manufacturer’s rated output (gpm) and be operated at the pump motors rated maximum continuous performance for the duration of pumping.

4.10.77.5 Vendor shall also provide a minimum of 100 feet of suction line, a minimum of 150 feet of discharge line and a bolt on float for each suction line upon request. Vendor shall provide all fittings and connections necessary for use of pumps in manner requested by agency.

4.10.78 2-inch Trash Water Pump.

4.10.78.1 Trash water pump must be 2-inch diameter input and output gas and/or diesel powered.

4.10.78.2 Mobilization and Demobilization shall be incidental to the hourly rate.

4.10.78.3 Set up and breakdown shall be incidental to the hourly rate.

4.10.78.4 Pump must be capable of producing a minimum 75% of the manufacturer’s rated output (gpm) and be operated at the pump motors rated maximum continuous performance for the duration of pumping.

4.10.78.5 Vendor shall also provide a minimum of 100 feet of suction line, a minimum of 150 feet of discharge line and a bolt on float for each suction line upon request. Vendor shall provide all fittings and connections necessary for use of pumps in manner requested by agency.

4.10.79 Engineering Fabric for Drainage

4.10.79.1 Engineering fabric for drainage must be for subsurface drainage – in accordance with Section 715.11.4 “Engineering Fabric” of the West Virginia Division of Highways, standard specification roads and bridges (non-woven).

4.10.80 Engineering Fabric for Stabilization

4.10.80.1 Engineering fabric for stabilization must be for separation and stabilization – in accordance with Section 715.11.8 and 715.11.9 “Engineering Fabric” of the West Virginia Division of Highways, standard specification roads and bridges (woven).

4.10.81 Textured HPDE Geomembrane

4.10.81.1 Textured HPDE geomembrane must be Poly-Flex 60 mil. or equivalent. Roll width may be site dependent.

4.10.81.2 Price shall include any necessary seaming and delivery to the site.

4.10.82 Laborer

4.10.82.1 Laborer must include basic hand tools i.e. shovel, chainsaw, drill, Stihl professional weed trimmer or equivalent, with minimum 1.4 bhp, etc.

4.10.82.2 Laborer shall be equipped to provide welding and or cutting torch services upon request.

4.10.82.3 Mobilization and demobilization shall be incidental to the hourly rate.

4.10.83 Silt fence

4.10.83.1 Silt fence must be provided and installed to manufacturer’s specifications, minimum 24-inch-high to conform to requirements of Section 715.11.5 of the WVDOH standard specification.

4.10.84 Grout

4.10.84.1 Grout must be provided to consist of one-part Portland cement and three parts sand mixed with water to produce workable consistency. Cement to meet requirement of Section 701.1 and sand to meet requirements of Sections 702.1 or 702.2 of the WVDOH standard specifications.

4.10.85 Concrete

4.10.85.1 Concrete must meet applicable provisions of Section 601 of the WVDOH standard specifications (Attachment A).

4.10.86 Landfill disposal fee

4.10.86.1 Landfill disposal fee must be only for trash and debris disposal. Transportation of items will be reimbursed under trucking bid item.

4.10.87 Hay bales

4.10.87.1 Hay bales must be provided on-site, installed and staked per standard OSR technical specifications.

4.10.88 3-foot Floating baffle curtains

4.10.88.1 3-foot Floating baffle curtains must be three (3) foot in depth, 18-ounce rubberized coated material with UV rating 20 x 20 nylon per square inch for strength, no sewing all seams heat seals.

4.10.88.2 Two (2) foot long styrofoam block for floats in top spaced with grommets in between each block, block size based on depth.

¼ inch stainless cable in main top and extended out to the point of anchorage, approximately ten (10) feet from edge of water.

4.10.88.3 5/16-inch chain, heat sealed into bottom, extended out each end to point of anchorage.

4.10.88.4 Price shall include delivery to site and all labor and materials for installation in pond, as required.

4.10.89 5-foot Floating baffle curtains

4.10.89.1 5-foot Floating baffle curtains must be five (5) foot in depth, 18-ounce rubberized coated material with UV rating 20 x 20 nylon per square inch for strength, no sewing all seams heat seals.

4.10.89.2 Two (2) foot long Styrofoam block for floats in top spaced with grommets in between each block, block size based on depth.

¼ inch stainless cable in main top and extended out to the point of anchorage, approximately ten (10) feet from edge of water.

4.10.89.3 5/16-inch chain, heat sealed into bottom, extended out each end to point of anchorage.

4.10.89.4 Price shall include delivery to site and all labor and materials for installation in pond, as required.

4.10.90 Wire mesh fencing

4.10.90.1 Zinc coated (galvanized) iron or steel farm-field (woven wire) fencing. Fencing shall meet the requirements of ASTM A 116, Design No. 1047-6-9, Zinc Coating Class 1. Where fencing is joined onto existing fence, Type FE-4-5 Oval Sleeve Wire Splices or equivalent splices will be used. Where fencing is attached to posts, 1 ½ inch galvanized fence staples will be used.

4.10.90.2 Price shall include delivery to site and all labor and materials for installation required.

4.10.91 Fence posts/Bracing posts 4-inch x 4-inch x 8-foot.

4.10.91.1 All posts must be extreme/severe (minimum AWPA Use Category UC4B or CCA rating of .40 weather treated wood. Square posts must be a minimum of 4-inch x 4 inch. Round posts may be used provided that a minimum of 6-inch diameter is used. Where installed in the ground, posts shall be installed a minimum depth of 3 feet with all fill compacted and extended above ground as directed.

4.10.91.2 Price shall include delivery to site and all labor and materials for installation.

4.10.92 Utility Relocation

4.10.92.1 Utility relocation is a no bid item and shall be reimbursed at actual cost.

4.10.93 Silt Bag

4.10.93.1 Bags shall be 10-foot x 15 foot with a 4-inch opening. Constructed of a permeable fabric.

4.10.93.2 Price shall include delivery to site and all labor and materials for installation.

4.10.94 Barbed Wire for Fencing

4.10.94.1 Wire must be a galvanized wire 15.5 gauge with 4-point Barbs. Rolls will be standard 1/4-mile (1320 foot) roll. Barbed wire shall be attached to fence post with metal wire staples.

4.10.94.2 Price shall include delivery to site and all labor and materials for installation.

4.10.95 Fence Posts/Bracing Posts, 6-inch x 6-inch x 8 foot

4.10.95.1 All posts must be extreme/severe (minimum AWPA). Use Category UC4B or CCA rating of .40 weather treated wood. Square posts must be a minimum of 6-inch x 6-inch x 8 foot. Round posts may be used provided that a minimum of 6-inch diameter is used. Where installed in the ground, posts must be installed a minimum depth of 3 feet with all fill compacted and extended above ground as directed.

4.10.95.2 Price shall include delivery to site and all labor and materials for installation.

4.10.96 Rolled Erosion Control Product (RECP)- Jute

4.10.96.1 Material must be Biodegradable 100% Jute fabric. Staples shall be used every 12 inches along the top and bottom edges to secure the fabric and every 18 to 24 inches across the fabric to minimize shifting. Square yardage calculations shall include a minimum of 4-inch overlap between sections.

4.10.96.2 Price shall include delivery to site and all labor and materials for installation.

4.10.97 Rolled Erosion Control Product (RECP)- Plastic

4.10.97.1 Material must be composed of at least 80% aspen wood fibers. Topped with a photo/biodegradable plastic netting. Green color is desirable. Biodegradable stakes shall be used to secure the material following the manufacturer's recommendation.

4.10.97.2 Price shall include delivery to site and all labor and materials for installation.

5. TRAVEL: Vendor shall be responsible for all mileage and travel costs, including travel time, associated with performance of this Contract. Any anticipated mileage or travel costs may be included in the flat fee or hourly rate listed on Vendor’s bid, but such costs will not be paid by the Agency separately.

6. FACILITIES ACCESS: Performance of Contract Services may require access cards and/or keys to gain entrance to Agency’s facilities. In the event that access cards and/or keys are required:

6.1 Vendor must identify principal service personnel which will be issued access cards and/or keys to perform service.

6.2 Vendor will be responsible for controlling cards and keys and will pay replacement fee, if the cards or keys become lost or stolen.

6.3 Vendor shall notify Agency immediately of any lost, stolen, or missing card or key.

6.4 Anyone performing under this Contract will be subject to Agency’s security protocol and procedures.

6.5 Vendor shall inform all staff of Agency’s security protocol and procedures.

7. Delivery: Inspection of each project will be made by the Director or his authorized representative as work is completed. A final inspection will be made when all work is completed. A Warranty inspection will be conducted on each project during the warranty period. Consideration will be made during the warranty period for unforeseen and unanticipated conditions encountered. A warranty period of one (1) year shall commence on final date of service as stated on the final invoice for the work directive. All items must be bid and bid in unit measure specified in the quantity column.

All equipment identified by trade name is interchangeable with an equivalent approved by the Department of Environmental Protection.

7.1 The quantities are applied for bidding purposes only; actual quantities shall be based on work performed and may be more or less depending on the necessity for maintenance work.

7.2 All equipment used must be in good operable condition at all times and be readily available.

7.3 All materials must have approval from a DEP representative.

7.4 Labor for operating equipment and installing materials shall be incidental to each item unless otherwise specified by the contract.

7.5 Labor for operating equipment and installing materials shall be incidental to each item unless otherwise specified by the contract.

7.6 Material Bid Items shall be priced as delivered to the site, with installation paid under labor and machine hours, unless specifically noted to the contrary.

8. REPORTS: The contractor shall provide written work reports on any / all projects at the request of the Director of the Office of Special Reclamation (OSR) or an authorized representative. Work reports will provide information necessary to evaluate the overall project and may include, (but not be limited to): type of equipment on site, equipment hourly use readings, man hours utilized, details of specific work performed at the site, specific problems encountered at the site, start and end times and date(s) of service. Report form will be provided by OSR or approved for use by OSR prior to use and submittal. Work reports will be constructed to illustrate day-to-day activity on the project and provide all required criteria.

9. VENDOR DEFAULT

9.1 The following shall be considered a vendor default under this Contract.

9.1.1 Failure to perform Contract Services in accordance with the requirements contained herein.

9.1.2 Failure to comply with other specifications and requirements contained herein.

9.1.3 Failure to comply with any laws, rules, and ordinances applicable to the Contract Services provided under this Contract.

9.1.4 Failure to remedy deficient performance upon request.

9.2 The following remedies shall be available to Agency upon default.

9.2.1 Immediate cancellation of the Contract.

9.2.2 Immediate cancellation of one or more release orders issued under this Contract.

9.2.3 Any other remedies available in law or equity.

11. MISCELLANEOUS:

11.1 Contract Manager: During its performance of this Contract, Vendor must designate and maintain a primary contract manager responsible for overseeing Vendor’s responsibilities under this Contract. The Contract manager must be available during normal business hours to address any customer service or other issues related to this Contract. Vendor should list its Contract manager and his or her contact information below.

Contract Manager: _________________________ Telephone Number: ________________________ Fax Number: ______________________________ Email Address: ____________________________

ATTACHMENT A

APPENDIX OF REFERENCED DOH SPECIFICATIONS

SECTION 601 STRUCTURAL CONCRETE

601.1-DESCRIPTION:

This work shall consist of furnishing and placing Portland cement concrete for structures, and incidental construction, in accordance with these specifications and in reasonably close conformity with the lines, grades and dimensions as shown on the Plans or established by the Engineer.

All concrete shall be air-entrained.

Classes of concrete shall be used as indicated below unless noted otherwise on the Plans:

Class A concrete shall be used in railing, cribbing, precast shapes, for filler, and in steel grid floors.

Class K concrete shall be used in all sidewalks, parapets, decks, and median barriers when they are part of the bridge superstructure.

Class B concrete shall be used in all beams and girders, roadway sidewalks, columns, hammerhead piers, arch rings including ties and spandrel walls, rigid frames, box culverts, heavily reinforced abutments, retaining walls, footings, pedestals and other areas not specifically designated as to class of concrete.

Class C concrete shall be used in massive footings and pedestals, massive pier shafts, gravity walls and, in general, for non-reinforced concrete or lightly reinforced concrete.

Class D concrete shall be used as unformed and non-reinforced concrete for backfilling of any excavated pockets or voids on which footings are to be located.

Class H concrete shall be used for bridge decks and other bridge elements when designated in the plans.

If the Contractor so elects, the Engineer may permit the use of a higher class concrete than the particular class designated for the work, in which event the higher class concrete shall meet the Specifications applicable without additional compensation. If the contractor uses a higher class concrete, and the strength specimens do not meet the minimum strength requirement of that higher class concrete, no penalty will be applied, provided that the strength specimens exceed the minimum strength requirement of the concrete that was originally designated for the work.

When called for on the Plans, an admixture of water-reducing retarder shall be added to all concrete so specified. A retarder may be used in other concrete at the Contractor’s option.

The work will be accepted in accordance with these Specifications and the applicable requirement of 105, 106, and 109.

All classes of concrete shall be designated as modified when using increased design strength.

All classes of concrete shall be designated as architectural when using additional formwork as shown in Section 601.8.10.

A hydration control admixture may be used at the Contractor’s option provided that the conditions in section 601.7 are met.

Shipping and Storage of Cement: Cement shall be shipped from retested and approved bins at the mill or distribution terminals, Cement stored by Contractor for a period longer than 90 days shall be retested before being used in the work. Cement failing to meet any of the specified requirements at any time prior to incorporation into the work will be rejected and shall be removed from the work. Cements of different brands, types, or from different mills shall be stored separately.

Shipping and Storage of Pozzolanic Additives: Pozzolanic additives shall be shipped from only those sources approved by the Division. Bulk Pozzolanic additives shall be stored at the job site in weatherproof bins. Pozzolanic additives from different sources or from different lots at the same source shall be stored separately.

701.1-PORTLAND CEMENT:

Portland cement shall conform to the requirements of ASTM C 150, Type I.

702.1-FINE AGGREGATE FOR PORTLAND CEMENT CONCRETE:

702.1.1-General Requirement: Fine aggregate shall consist of natural sand, manufactured sand, or a combination thereof, conforming to the requirements of these Specifications.

702.1.2-Deleterious Substances: The Maximum percentages of deleterious substances shall not exceed the limits below.

MATERIAL
PERCENT BY WEIGHT

Amount finer than No. 200 (75 µm) sieve for manufactured fine aggregate (determined by AASHTO T 11 and T 27) A manufactured fine aggregate is one which has been reduced in particle size by crushing.

Amount finer than No. 200 (75 µm) sieve for all other sands (determined by AASHTO T 11 and T 27)
3
Coal and other lightweight deleterious material (determined by MP 702.01.20)
2
Friable particles (determined by MP 703.01.20)
1

Larger percentages passing the No.200 (75 µm) sieve in the fine aggregate fraction will be permitted if the percent passing the No. 200 (75 µm) sieve in the coarse aggregate fraction (703.4) is less than the specified maximum. In no event, however, shall the percent passing the No. 200 (75 µm) sieve in the total concrete aggregate be greater than an amount which would exist if both aggregate fractions contained their specified maximum percentage passing the No. 20 (75 µm) sieve.

702.1.3-Soundness (Determined by NP 703.00.22): When the fine aggregate is subjected to five alternations of the sodium sulphate soundness test, the weighted loss shall not exceed 10 percent by weight.

702.1.4-Organic Impurities (Determines by AASHTO T21): When the fine aggregate is subjected to the organic impurities test, the color shall not be darker than the standard. In the event a color darker than the standard is produced, the acceptability of the material will be determined as specified in 702.1.5.

702.1.5-Mortar Strength (Determined by AASTHO T71): Fine aggregate failing the organic impurities test shall be subjected to the test for mortar making properties. The fine aggregate shall develop a compressive strength at the age of seven days when sing Type I or II cement, or at three days when using Type III cement, of no less than 90 percent of the strength developed by a mortar prepared in the same manner with the same cement and graded Ottawa sand having a fineness modulus of 2.4 plus or minus 0.10.

702.1.7-Uniformity of Grading: The gradation limits given in 702.1.6 represent the extreme limits which shall determine suitability of material from all sources of supply. The gradation of material from any one source, however, shall be reasonable uniform.

702.2-MORTAR SAND:

Sand (natural or manufactured) shall meet the requirement of AASHTO M 45, except delete 4.1 through 4.4 and substitute the following:

Aggregate for use in masonry mortar shall be graded within the following limits:

SIEVE SIZE
PERCENT PASSING
No. 4(3.75 mm)
100
No. 8 (2.36 mm)
90-100
No. 100 (150 µm)
0-30
No. 200 (75 µm)
0-10

715.11.4-Engineering Fabric For Subsurface Drainage: Engineering fabric for subsurface drainage shall meet the applicable requirements of AASHTO M 288, Section 7, Class 2. Additionally, the permittivity shall be a minimum of 0.2 sec-1 and the apparent opening size shall be no larger than No. 60 (250 µm) sieve.

715.11.5-Engineering Fabric For Sediment Control (Silt Fence): Engineering fabric for sediment control shall beet the applicable requirements of AASHTO M 288, Section 8.

715.11.8-Engineering Fabric For Separation: Engineering fabric for separation shall meet the applicable requirement of AASHTO M 288, Section 7, Class 2.

715.11.9-Engineering Fabric For Stabilization: Engineering fabric for stabilization shall meet the applicable requirement of AASHTO M 299, Section 7, Class 1.

Permit Numbering Series http://www.wvgs.wvnet.edu/oginfo/pipeline/series.html West Virginia Geological and Economic Survey http://www.wvgs.wvnet.edu/ Precision Services, Inc. Document Warehouse http://depcitrucfs.executive.stateofwv.gov/ GIS/WVDEP Resource Data View http://tagis.dep.wv.gov/fogm/

9'

114" STEEL PLA're (WELDED CONSTRIJCllON)12·

WELD POINT

GA're PIPE

WELD

ENTIRE CIRCUMFERENCE

soxrr:, PIPE

OFLOCK

LOCK BOX DETAIL

18' f f/2 " I.D.UNE PIPE ONINSIDE, WELDED ONENDS TOBEUSEDAS HINGEPINS (Typical_,-•l

3'

AREA TOBEEXCAVATED TOALLOW FORINSTALJ.ATION OFGATE, BACKFILLED ANDCOMPACTED.

NOTES: GREASEFTT11NGSSHALL BEINSTALLED AT EACHHINGEPOINT.

ALL ENDSOF PIPESHALL BE WELDEDCLOSED. ALL STEELPIPESHALL BESCHEDULE#.

PIPEGATE, 18-FOOT DETAIL

6" 1.0. PIPE, WELDED

(TYPICAL BOlli SIOES)

'"U '"U m G) m

0m0·

:::0 mI z image1.png image2.png image3.png image4.png image5.png

File details come from the government source that posted it. Updated .