RFQ_CDS250560_Euster_Brown_Rehabilitation_-_Addendum_2.pdf
PDF 137 KB Posted
- Attached to
- Euster Brown Rehabilitation
- Solicitation number
- RFQ# CDS/250560
- Issued by
- Marion County, Orlando City, Florida
About this file
This document is Addendum #2 for the City of Ocala's Request for Quotation (RFQ# CDS/250560) for the Euster Brown Rehabilitation project. The addendum provides specific details for contractors regarding rehabilitation work, including modifications to plumbing, HVAC, electrical systems, and water heater installation. Key scope items include adding a cleanout at the front of the home, installing a shower valve/head trim kit, building a closet for the air handler, replacing interior and exterior light fixtures with LED-compatible options, and installing the water heater in the same closet as the air handler. The addendum is dated June 23, 2025, and is addressed to all bidders, with instructions that all proposed changes and fixtures must be approved by the owner or Rehab Specialist.
While the addendum itself does not provide pricing or funding details, the associated contract opportunity summary indicates this is a comprehensive residential rehabilitation project for a property located at 617 NW 1st Street in Ocala, Florida. The project requires Florida-licensed General or Building Contractors to complete a full home renovation within 90 days, with a 10-day maximum start after the Notice to Proceed. Contractors must have a minimum of three years of residential rehabilitation experience and carry $1,000,000 per occurrence Commercial General Liability insurance. The project includes a $300 permit cost allowance, requires obtaining all necessary City of Ocala permits, and mandates a 12-month material and labor warranty.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Date: June 23, 2025
To: All bidders
From: Ashley Presley, Buyer
Solicitation Number: RFQ# CDS/250560
Solicitation Title: Euster Brown Rehabilitation
Item 2 Plumbing
• Add cleanout at the front of home between city sewer and vent. Secure vent from falling as necessary.
Install shower valve/head trim kit in front bathroom. Replace valve as necessary.
Item 4 HVAC
• Build closet in area where current air handler is located. Closet shall be closed on all sides except for access door/s at the front. Closet shall be built from wall to wall.
Item 5 Electrical
• Install LED bulbs in exterior all exterior fixtures. Replace all interior light fixtures with builder grade
(Project Source equal/better) fixtures capable of receiving standard LED bulbs w/medium base.
Replace ceiling fans with similar size. Living room chandelier can remain if owner wants to keep it and it works, otherwise replace with standard fixture. Fixtures shall be approved by the owner or the
Rehab Specialist. Smoke alarms are addressed in the Work Write Up.
Item 6 Water Heater
• Water heater shall be installed in the same closet as the air handler.
Addendum # 2
SECTION 1. SOLICITATION ADDITIONS, CLARIFICATIONS AND CORRECTIONS
| Item 2 Plumbing |
| Add cleanout at the front of home between city sewer and vent. Secure vent from falling as |
| necessary. |
| Install shower valve/head trim kit in front bathroom. Replace valve as necessary. |
| Item 4 HVAC |
| Item 5 Electrical |
| Item 6 Water Heater |
| Water heater shall be installed in the same closet as the air handler. |