RFP 27-20 - Drawings.pdf
PDF 19 MB Posted
- Solicitation number
- 2138156
- Issued by
- Erie County, New York
About this file
RFP 27-20: 907 Michigan Ave Community Outreach and Engagement Center Phase II
This is a Request for Proposals (RFP) issued by Roswell Park Comprehensive Cancer Center for general construction management services related to Phase II of the Community Outreach and Engagement Center located at 907 Michigan Avenue, Buffalo, New York. The project involves construction of an approximately 4,600 square foot addition to the existing facility, including a 20+ seat classroom, large collaboration room, two community co-working rooms, semi-private drop-down areas, public gathering space, and expansion of the community gallery. The expansion will also include private offices and hoteling workstations to support additional staff, with a partial second story and basement designed to accommodate future growth and storage. The RFP was issued on August 10, 2026, with a pre-bid meeting scheduled for Monday, August 24, 2026. Interested bidders must contact Rob Henschel at rob.henschel@roswellpark.org with "RFP #27-20" in the subject line to receive the complete request for proposals document.
The project is subject to Minority and Women-Owned Business Enterprise (MWBE) contracting goals of 15 percent for Minority Business Enterprises (MBE) and 15 percent for Women Business Enterprises (WBE), with a Service-Disabled Veteran-Owned Business (SDVOB) goal of 6 percent. Roswell Park strongly encourages selected firms to team or partner with MWBEs in their proposals. Prior awards for identical or substantially similar procurements have been made to Telco Construction, Arc Construction, LeChase Construction, and The Liro Group. The construction documents include detailed architectural, structural, civil, mechanical, fire protection, plumbing, and electrical drawings prepared by Young Architectural LLC with consultation from Siracuse Engineers PC, Salas O'Brien Consulting and Engineering, and Watts Architects & Engineers. The construction documents set an expiration date of May 31, 2027, and December 31, 2028, for various permit and design specifications.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFP 27-20 - Specifications.pdf | ||
| RFP 27-20 Addendum 1_9.2.26.pdf | ||
| RFP 27-20 Addendum 2_9.9.26.pdf | ||
| RFP 27-20 Addendum 3_9.16.26.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EARTH
X
X
X
XX
X
ARCHITECTURAL SYMBOLS
X
XX
XAXXX
X
X
X
GRAVEL
CONCRETE
MASONRY (CMU)
MASONRY (BRICK)
STEEL
GYPSUM WALL BOARD
RIGID INSULATION
PLYWOOD
WOOD
BATT INSULATION
WOOD BLOCKING
DEMOLITION KEYED NOTE
KEYED NOTEX
DOOR TYPE
WINDOW TYPEX
PARTITION TYPE
DETAIL IDENTIFICATION
ALTERNATE NUMBER
SPACE IDENTIFICATION
ALT. #____
ROOM
XX
XX SF
SECTION MARKER
ELEVATION MARKER
EXTERIOR ELEVATION X
XX
NORTH ARROW
GRAPHIC DESCRIPTION
METAL PANEL
DRAWING LIST
SHEET
NUMBER SHEET NAME
GENERAL
G001 COVER SHEET
G002 CODE COMPLIANCE REVIEW
CIVIL
C101 CIVIL DEMOLITION AND ESC PLAN
C111 CIVIL SITE PLAN
C121 CIVIL SITE UTILITY PLAN
C131 CIVIL SITE GRADING PLAN
C501 CIVIL ESC AND SITE DETAILS
C502 CIVIL PLANNING AND UTILITY DETAILS
STRUCTURAL
S001 SYMBOLS, ABBREVIATIONS, GENERAL NOTES & DESIGN CRITERIA
S002 COMPONENTS & CLADDING WIND LOADING
S003 CONCRETE PIER DETAILS
S004 TYPICAL CONCRETE DETAILS
S005 TYPICAL FRAMING DETAILS
S006 COLUMN SCHEDULE & COLUMN BASE DETAILS
S006.1 COLUMN SCHEDULE & COLUMN BASE DETAILS - ALTERNATE 1
S007 SHEAR WALL DETAILS
S007.1 SHEAR WALL DETAILS - ALTERNATE 1
S100 FOUNDATION / FIRST FLOOR PLAN
S100.1 FOUNDATION / FIRST FLOOR PLAN - ALTERNATE 1
S101 SECOND FLOOR / LOW ROOF FRAMING PLAN
S101.1 TRUSS BOTTOM CHORD / LOW ROOF FRAMING PLAN - ALTERNATE 1
S102 ROOF FRAMING PLAN
S102.1 ROOF FRAMING PLAN - ALTERNATE 1
S200 CONCRETE SECTIONS
S201 FRAMING SECTIONS
S201.1 FRAMING SECTIONS - ALTERNATE 1
ARCHITECTURE
AD001 FIRST FLOOR & ROOF DEMOLITION PLANS
A001 FIRST FLOOR PLAN
A001.1 FIRST FLOOR PLAN - ALTERNATE 1
A002 SECOND FLOOR PLAN
A002.1 SECOND FLOOR PLAN - ALTERNATE 1
A003 ROOF PLAN
A101 FIRST FLOOR REFLECTED CEILING PLAN
A102 SECOND FLOOR REFLECTED CEILING PLAN
A201 EXTERIOR ELEVATIONS & BUILDING SECTIONS
A351 WALL SECTIONS
A400 INTERIOR ELEVATIONS AND TYPICAL TOILET FIXTURE MOUNTING HEIGHTS
A451 ENLARGED STAIR PLAN AND DETAILS
A501 ROOF DETAILS
A502 INTERIOR AND MILLWORK DETAILS
A600 DOOR SCHEDULE, DOOR & FRAME TYPES, PARTITION TYPES
A601 CURTAIN WALL TYPE, STOREFRONT TYPE, AND DETAILS
A700 MATERIAL FINISH AND SIGNAGE LEGENDS AND TRANSITION DETAILS
A701 FIRST FLOOR FINISH PLAN
MECHANICAL
M001 FIRST FLOOR PLANS - HVAC
M001.1 FIRST FLOOR PLAN - HVAC - ALTERNATE 1
M002 PARTIAL ROOF PLANS - HVAC
M401 ENLARGED MECHANICAL ROOM PLANS - HVAC
M401.1 ENLARGED MECHANICAL ROOM PLANS - HVAC - ALTERNATE 1
M601 SYMBOLS LIST, SCHEDULES & DETAILS - HVAC
M701 TEMPERATURE CONTROLS - HVAC
FIRE PROTECTION
FP000 SYMBOL LIST, GENERAL NOTES AND DETAILS - FIRE PROTECTION
FP001 FLOOR PLANS - FIRE PROTECTION
FP001.1 FLOOR PLANS - FIRE PROTECTION - ALTERNATE 1
PLUMBING
P000 SYMBOLS LIST, GENERAL NOTES, DETAILS AND SCHEDULES - PLUMBING
P001 SITE PLAN - PLUMBING
P002 FOUNDATION PLAN - PLUMBING
P003 FIRST FLOOR PLAN - PLUMBING
P004 PARTIAL FLOOR PLANS - PLUMBING
P500 DETAILS - PLUMBING
ELECTRICAL
E000 SYMBOLS LIST, LUMINAIRE SCHEDULE AND GENERAL NOTES - ELECTRICAL
E001 SITE PLAN - ELECTRICAL
E002 FIRST FLOOR PLAN - LIGHTING
E003 FIRST FLOOR PLAN - POWER & SYSTEMS
E004 SECOND FLOOR PLAN - POWER, SYSTEMS & LIGHTING
E004.1 SECOND FLOOR PLAN - POWER, SYSTEMS & LIGHTING - ALTERNATE 1
E500 DETAILS - ELECTRICAL
E600 ONE-LINE DIAGRAM & SCHEDULES - ELECTRICAL
PROJECT INFORMATION:
ISSUE DATE:
REVISIONS:
SHEET TITLE:
This is a single sheet of a cohesive set of construction documents, including drawings and specifications. Interpretation of information presented is to be based on the entire set of documents
Drawn By:
Project NO.:
Copyright 2026, Young Architectural, LLC
REV. DATE DESCRIPTION
EXPIRATION DATE:
CIVIL ENGINEER
BUFFALO OFFICE
50 ELK ST. STE 200
BUFFALO, NY 14210
FAX: 716.842.1807
ROCHESTER OFFICE
85 ALLEN ST. STE 310
ROCHESTER,NY 14608
FAX: 585.461.4771
PHONE: 716.842.1800
WWW.YOUNGANDWRIGHT.COM
CONSULTANTS:
SITE LOCATION MAP
STRUCTURAL ENGINEER
MEP ENGINEER
CIVIL ENGINEER
MEP ENGINEER STRUCTURAL ENGINEER
It is a violation of the law for any person, unless acting under the direction of a licensed architect, to alter an item in any way. If an item bearing the seal of an architect is altered, the altering architect shall affix to his item the seal and the notation "altered by" followed by his signature and the date of such alteration, and a specific description of the alteration
SHEET NUMBER:
ADDITIONAL BUILDINGS:
BID DOCUMENTS
G001
COVER SHEET
ROSWELL 907
COMMUNITY
OUTREACH AND
ENGAGEMENT
CENTER
CT/CK/BH/JD
08/10/2026
25103
ROSWELL PARK
907 MICHIGAN AVE
BUFFALO, NY, 14203
716.845.2300 www.roswellpark.org
COMMUNITY OUTREACH & ENGAGEMENT CENTER
960 BUSTI AVENUE, SUITE 120
BUFFALO, NY 14213
716.852.1894 EXT.116
www.siracusengineers.com
SIRACUSE ENGINEERS PC
60 LAKEFRONT BOULEVARD, SUITE 320
BUFFALO, NY 14202
716.845.5092 www.salasobrien.com
Salas O'Brien Consulting and Engineering
95 PERRY STREET, SUITE 300
BUFFALO, NY 14203
716.206.5100 watts-ae.com
WATTS ARCHITECTS & ENGINEERS
05.31.2027
SIRACUSE ENGINEERS PC
716.852.1894 EXT.116
Salas O'Brien Consulting and Engineering
716.845.5092
WATTS ARCHITECTS & ENGINEERS
716.206.5100
907 MICHIGAN AVE
BUFFALO, NY 14203
ROSWELL 907 COMMUNITY OUTREACH AND ENGAGEMENT CENTER
907 MICHIGAN AVE
BUFFALO, NY 14203
08/10/2026
ROSWELL COMMUNITY OUTREACH AND
ENGAGEMENT CENTER
PHASE 2
PHASE 2
ROSWELL COMMUNITY OUTREACH AND ENGAGEMENT CENTER
PR#: 25103
PR#: 251236.00
PR#: 20250675
A / E ARCHITECT / ENGINEER
ACT ACOUSTICAL TILE OR PANE
ADA AMERICANS WITH DISABILITIES ACT
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
ALT ALTERNATE / ALTERNATIVE
AP ACCESS PANEL
APPROX APPROXIMATELY
ASB ASBESTOS
ASTM AMERICAN SOCIETY FOR TESTING & MATERIALS
AWT ACOUSTICAL WALL TREATMENT
BC BUILDING CODE
BD BOARD
BFF BELOW FINISHED FLOOR
BM BENCHMARK
BOS BOTTOM OF STEEL
BRDG BRIDGING
BRK FACE BRICK
BUR BUILT - UP ROOFING
CAB CABINET
CB CATCH BASIN
CD CONSTRUCTION DOCUMENTS
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLL CONTRACT LIMIT LINE
CMT CERAMIC MOSAIC TILE
CMTB CERAMIC MOSAIC TILE BASE
CMU CONCRETE MASONRY UNIT
CO CLEANOUT
COL COLUMN
CONC CAST IN PLACE CONCRETE
CPT CARPET
CPTB CARPET BASE
CR CLOSET ROD
CRG CORNER GUARD
CRT COLORED CONCRETE
CT CERAMIC TILE
CTB CERAMIC TILE COVER BASE
CTR CENTER
CW COLD WATER
DBL DOUBLE
DEMO DEMOLITION
DET DETAIL
DF DRINKING FOUNTAIN
DIM DIMENSION
DL DEAD LOAD
DN DOWN
DOUG FIR DOUGLAS FIR
DR DOOR
DW DISHWASHER
DWG DRAWING
EC ELECTRICAL CONTRACTOR
EGB EXTERIOR GYPSUM BOARD
EIFS EXTERIOR INSULATION & FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ENTR ENTRANCE
EPNT EPOXY PAINT
EQ EQUAL
ERD EXISTING ROOF DRAIN
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXP EXPOSED
EXP BT EXPANSION BOLT
EXT EXTERIOR
EXT GR EXTERIOR GRADE
FD FLOOR DRAIN
FDTN FOUNTAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISHED FLOOR
FF&E FURNITURE, FIXTURE & EQUIPMENT
FIN FINISH
FLM FLOOR MAT
FOS FACE OF STUD
FOW FACE OF WALL
FT FEET / LONG
FTG FOOTING
FV FIELD VERIFY
GB GRAB BAR
GC ALL CONTRACTOR
GLU LAM GLUED LAMINATED BEAM
GR GRADE
GWB GYPSUM WALL BOARD
HC HANDICAP
HCWD HOLLOW CORE WOOD DOOR
HD HEAVY DUTY
HDWD HARDWOOD
HM HOLLOW METAL
HT HEIGHT
HVAC HEATING, VENTILATING, AIR CONDITIONING
HWY HARDWOOD FLOOR
HYD HYDRANT
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION / INSULATED
INT INTERIOR
JT JOINT
KD KILN DRIED
KIT KITCHEN
LAM LAMINATED
LAV LAVATORY
LCD LINEAR CEILING DIFFUSER
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LWC LIGHTWEIGHT CONCRETE
MAX MAXIMUM
MC MECHANICAL CONTRACTOR
MDO MEDIUM DENSITY OVERLAY
MF MILL FINISH
MFD MANUFACTURED
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MR MOISTURE RESISTANT
MWP MEMBRANE WATERPROOFING
NA NOT APPLICABLE
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OA OUTSIDE AIR
OC ON CENTER
OF OUTSIDE FACE
OFCI OWNER FURNISHED - CONTRACTOR INSTALLED
OH DR OVERHEAD DOOR
PA PIPE ANCHOR
PBD PARTICLE BOARD
PC PLUMBING CONTRACTOR
PCC PRECAST CONCRETE
PEJ PRE-MOLDED EXPANSION JOINT
PL PROPERTY LINE
PLAM PLASTIC LAMINATE
PNT PAINT / PAINTED
PR PORCELAIN TILE
PRB PORCELAIN TILE BASE
PREFAB PREFABRICATED
PTAC PACKAGED TERMINAL AIR CONDITIONER
PVC POLYVINYL CHLORIDE
QT QUARRY TILE
QTB QUARRY TILE BASE
QTY QUANTITY
R RADIUS
RA RETURN AIR
RC REINFORCED CONCRETE
RCB RUBBER COVER BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REBAR REINFORCING STEEL BARS
REF REFRIGERATOR
REINF REINFORCING
REQD REQUIRED
REV REVISION
RFLM RECESSED FLOOR MAT
RM ROOM
RO ROUGH OPENING
RTU ROOF TOP UNIT
RW RESCUE WINDOW
SA SUPPLY AIR
SCWD SOLID CORE WOOD DOOR
SD STORM DRAIN
SF SQUARE FOOT / SQUARE FEET
SHT SHEET
SIM SIMILAR
SJI STEEL JOIST INSTITUTE
SK SKETCH
SPF SPRUCE - PINE - FIR
SS STAINLESS STEEL
STC SOUND TRANSMISSION COEFFICIENT
STD STANDARD
T&G TONGUE & GROOVE
TB THROUGH BOLT
TEMP TEMPERED
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOS TOP OF STEEL
TR THERMAL RESISTANCE
TYP TYPICAL
UBC UNIFORM BUILDING CODE
UH UNIT HEATER
UL UNDERWRITERS LABRATORIES
UNO UNLESS NOTED OTHERWISE
UV UNIT VENTILATOR
VAR VARIES
VCB VINYL COVER BASE
VCT VINYL COMPOSITE TILE
VEST VESTIBULE
VIF VERIFY IN FIELD
VS VENT STACK
VSN VINYL STAIR NOSING
VYL VINYL WALL COVERING
WC WATER CLOSET
WCO WALL CLEAN OUT
WD WOOD
WH WALL HUNG
WL WIND LOAD
WWF WELDED WIRE FABRIC
WWM WELDED WIRE MESH
STANDARD ABBREVIATIONS
Bid 08.10.26 BID DOCUMENTS
FP-1HR FP-1HRFP-1HR
FB-1HR FB-1HRFB-1HR
FW-1HR FW-1HRFW-1HR
FP-2HR FP-2HRFP-2HR
E1FP E1FPE1FP
E1FB E1FBE1FB
UP
DN DN
DN
UP
FP-1HR FP-1HR
E1FB E1FBE1FB E1FB
E1
FB
E1
FB
E1
FB
E1
FB
E1FB E1FBE1FB
E1
FB
E1FB E1FBE1FB
E1FB E1FBE1FB E1FB E1FB E1FB E1FB
E1
FB
E1
FB
E1
FB
E1
FB
E1
FB
E1FB E1FBE1FB E1FB E1FB E1FB E1FB E1FB E1FB
E1
FB
E1
FB
E1
FB
E1FB E1FBE1FB E1FB E1FB E1FB E1FB
E1FBE1FB
E1FBE1FB
E1
FB
E1
FB
FB-1HR FB-1HR
FB-1HR FB-1HR
FB-1HR FB-1HR
FB
-1
H R
FB
-1
H R
FB
-1
H R
FB
-1
H R
FB
-1
H R
FB
-1
H R
FB
-1
H R
FP-1HR FP-1HRFP-1HR
FP-1HR FP-1HRFP-1HR
FP-1HRFP-1HR
FP-1HR FP-1HRFP-1HR FP-1HR FP-1HR FP-1HR FP-1HR FP-1HR
FP-1HR FP-1HRFP-1HR FP-1HR
FP-1HR
FP
-1
H R
FP
-1
H R
FP
-1
H R
FP-1HR FP-1HRFP-1HR FP-1HR
FP
-1
H R
CODE PLAN SYMBOLS
EFE
EXISTING FIRE EXTINGUISHER
FE
FIRE EXTINGUISHER
AED
NEW AUTOMATED EXTERNAL DEFIBRILLATOR
EXIT SIGN
DIRECTIONAL EXIT SIGN
RW RESCUE WINDOW
R AREA OF REFUGE
E-X BUILDING EXIT NUMBER
LEVEL 2 ALTERATIONS
ADDITION
EGRESS PATH & TRAVEL DISTANCE
HANDICAPPED / ACCESSIBLE SPACE / STATION
FEC
FIRE EXTINGUISHER AND CABINET
X' - X"X' - X"
DF DRINKING FOUNTAIN
1 HOUR RATED
FIRE PARTITION
1 HOUR RATED
FIRE BARRIER
1 HOUR RATED
FIRE WALL
2 HOUR RATED
FIRE PARTITION
FIRE RATING LEGEND
EXISTING 1
HOUR RATED
FIRE PARTITION
EXISTING 1
HOUR RATED
FIRE BARRIER
SMOKE ZONE
DEMARCATION
BUILDING AREA INFORMATION
FIRE AREA INFORMATION
FIRE AREA
BUILDING AREA 1ST FLOOR & 2ND FLOOR OCCUPIABLE SF
NOTE: BUILDING AREAS ARE ASSUMED BASED ON AVAILABLE INFORMATION PROVIDED IN
RECORD DRAWINGS AND DIRECT FIELD OBSERVATION. CONDITIONS THAT ARE CONCEALED
BY EXISTING CONSTRUCTION OR NOT DETAILED IN AVAILABLE RECORD DRAWINGS MAY
DIFFER FROM THE ARCHITECT'S ASSUMPTIONS.
EXISTING
BUILDING AREA 1 5,874 SF
ACTUAL SF ALLOWABLE SF
11,311 SF (SEE ALLOWABLE
BUILDING AREA)
FIRE
AREA 1 10,917 SF
PROPOSED ADDITION
BUILDING AREA 4,487 SF
TOTAL BUILDING AREA 10,361 SF
ASSEMBLY
616 SF
COMMUNITY HALL
J-202
BUSINESS
239 SF
COE LAB CONFERENCE
ROOM
J-203
BUSINESS
93 SF
COE LAB
STUDIO 1
J-210
BUSINESS
95 SF
COE LAB
STUDIO 2
J-209
STORAGESTORAGE
71 SF
STORAGE
J-208
489 SF
CORRIDOR
J-201
BUSINESS
32 SF
WORKSPACE
J-206
BUSINESS
103 SF
COE OFFICE
J-207
BUSINESS
115 SF
COE OFFICE
J-218
BUSINESS
94 SF
COE OFFICE
J-216
204 SF
OFFICE HALLWAY
J-214
BUSINESS
118 SF
COE OFFICE
J-219
BUSINESS
94 SF
COE OFFICE
J-215
68 SF
WELLNESS ROOM
J-213
43 SF
T.R.
J-212
48 SF
T.R.
J-211
BUSINESS
116 SF
COE OFFICE
J-221
STORAGESTORAGE
158 SF
MECHANICAL
J-107C
BUSINESS
113 SF
OFFICE
J-110
BUSINESS
99 SF
OFFICE
J-111
BUSINESS
112 SF
OFFICE
J-112
BUSINESS
104 SF
OFFICE
J-113
BUSINESS
103 SF
OFFICE
J-109
89 SF
CORRIDOR
117A
152 SF
MEN TLT
J-115T
138 SF
WOMEN TLT
J-114T
ASSEMBLY
896 SF
CONFERENCE ROOM
J-118
99 SF
VESTIBULE
J-122
STORAGESTORAGE
120 SF
STORAGE
J-123
98 SF
KITCHEN
J-120
51 SF
TOILET
J-116T
BUSINESS
71 SF
OFFICE
J-106
STORAGESTORAGE
75 SF
STORAGE
J-103
BUSINESS
85 SF
CONSULT
J-102
BUSINESS
118 SF
COE OFFICE
J-220
BUSINESS
84 SF
WORKROOM
J-105
BUSINESS
426 SF
RECEPTION
J-108
33 SF
ENTRY
J-101
BUSINESS
245 SF
COMMUNITY COMMONS
J-204
'-6
'-6
62'-6"62'-6"
BUSINESS
32 SF
WORKSPACE
J-205
48'-6"48'-6"
EFE
19' - 10"19' - 10"
EFE
EFE
EFE
30 SF
RISER ROOM
J-217
17 SF
CUSTODIAN
FE
30' - 10"
47' - 2" 24' - 11"
30' - 7"
E-X
E-X
E-X
E-X
C
481 SF
MECHANICAL
J-223
STORAGESTORAGE
530 SF
MECHANICAL
J-224
OPEN TO BELOW
ROOF BELOW
27' - 8"
FE
30' - 6"
YEARS OF CONSTRUCTION
YEAR OF
CONSTRUCTION
ORIGINAL
TOTALS
221 SF
BASEMENT FIRST FLOOR SECOND FLOOR ADDITION SIZE
383 SF
604 SF
1,637 SF
3,567 SF
3,281 SF
8,485 SF
625 SF
1,206 SF
1,828 SF
2,483 SF
3,950 SF
4,487 SF
10,917 SF
(3,950 SF)PROPOSED
ADDITION
(4,487 SF)
ORIGINAL
(2,483 SF)
PLUMBING FIXTURE CALCULATION
OCCUPANCY REQUIRED AMOUNT PER OCCUPANCY
TOTAL AMOUNT OF PLUMBING
FIXTURES REQUIRED
PER OCCUPANCY LOAD
6 6
LAVATORIESWATER CLOSETS
TOTAL AMOUNT OF PLUMBING
FIXTURES PROVIDED
LAVATORIES
1 11 PER 40 FOR
FIRST 80, 1
PER 80 FOR
REMAINDER
LAVATORIESWATER CLOSETSBUSINESS
OCCUPANTS
MALE AND FEMALE
1 PER 25 FOR FIRST 50, 1 PER
50 FOR REMAINDER
WATER CLOSETS
99 FEMALE
1 PER 65
LAVATORIES
1 11 PER 200
LAVATORIESWATER CLOSETSASSEMBLY
OCCUPANTS
MALE
1 PER 125
WATER CLOSETS
5 FEMALE
1 PER 100
LAVATORIES
1 11 PER 100
LAVATORIESWATER CLOSETSSTORAGE
OCCUPANTS
MALE
1 PER 100
WATER CLOSETS
3 3
LAVATORIESWATER CLOSETS
TOTAL AMOUNT OF PLUMBING
FIXTURES REQUIRED
EXPIRATION DATE:
BUFFALO OFFICE
50 ELK ST. STE 200
BUFFALO, NY 14210
FAX: 716.842.1807
ROCHESTER OFFICE
85 ALLEN ST. STE 310
ROCHESTER,NY 14608
FAX: 585.461.4771
PHONE: 716.842.1800
WWW.YOUNGANDWRIGHT.COM
PROJECT INFORMATION:
SHEET TITLE:
This is a single sheet of a cohesive set of construction documents, including drawings and specifications. Interpretation of information presented is to be based on the entire set of documents
Drawn By:
Project NO.:
Copyright 2026, Young Architectural, LLC
It is a violation of Title VIII, Arcticle 147 of NYS Education Law for any person, unless acting under direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to affix his or her seal and the notation
"altered by" followed by his or her signature and a specific description of the alterations made.
SHEET NUMBER:
CONSULTANTS:
STRUCTURAL ENGINEER
MEP ENGINEER
CIVIL ENGINEER
ISSUE DATE:
REVISIONS:
REV. DATE DESCRIPTION
ADDITIONAL BUILDINGS:
05.31.2027
G002
CODE COMPLIANCE
REVIEW
ROSWELL 907
COMMUNITY
OUTREACH AND
ENGAGEMENT
CENTER
CT
25103
SIRACUSE ENGINEERS PC
716.852.1894 EXT.116
Salas O'Brien Consulting and Engineering
716.845.5092
WATTS ARCHITECTS & ENGINEERS
716.206.5100
PR#: 25103
PR#: 251236.00
PR#: 20250675
08/10/2026
907 MICHIGAN AVE
BUFFALO, NY 14203
ROSWELL COMMUNITY OUTREACH AND
ENGAGEMENT CENTER
PHASE 2
YESNOSPRINKLER
CODE COMPLIANCE INFORMATION
THE FOLLOWING PAGES ARE AN EVALUATION BASED ON OUR INTERPRETATION OF EXISTING BUILDING CODE OF NEW YORK STATE 2025, THE BUILDING CODE OF NEW YORK STATE 2025, AND THE 2025 NYS ASHRAE CODES. FURTHER MODIFICATIONS TO THIS DOCUMENTS AND THE CONSTRUCTION DRAWINGS MAY BE REQUIRED UPON REVIEW BY THE LOCAL MUNICIPALITY HAVING JURISDICTION.
DESCRIPTION OF PROJECT: THE PROJECT CONSISTS OF ADDITION AND ALTERATIONS TO THE EXISTING ROSWELL COMMUNITY OUTREACH
AND ENGAGEMENT CENTER LOCATED IN 907 MICHIGAN AVENUE, BUFFALO, NY.
BUILDING SUMMARY
EXISTING ADDITION
GROUP B - BUSINESS
TYPE 5B
2 STORIES
APPROXIMATELY 26' - 1/2"
YES
YES
YES
YESYES
YES
YES
YES
GROUP B - BUSINESS
TYPE 5B
2 STORIES
APPROXIMATELY 26' - 1/2"
BUILDING OCCUPANCY
CONSTRUCTION CLASSIFICATION
HEIGHT (STORIES)
HEIGHT (FEET)
AUTOMATIC FIRE DETECTION
FIRE ALARM SYSTEM
SMOKE CONTROL
MEANS OF EGRESS LIGHTING
SCALE: 1/8" = 1'-0"1 FIRST FLOOR CODE COMPLIANCE PLAN
SCALE: 1/8" = 1'-0"2 SECOND FLOOR CODE COMPLIANCE PLAN
132OCCUPANT LOAD (BUILDING TOTAL)
MICHIGAN AVENUE (66.0')
C O
N C
. W
AL
K
C O
N C
. W
AL
K
C O
N C
. W
AL
K
C O
N C
. W
AL
K
COVERED
WD. PO.
8.
0'
6.2'
9.
3'
6.
6'
COVERED
CONC. PO.
CONC.
UTILITY PAD
14.7'
7.
2'
1 STY. W.F.
BUILDING #907
C O
N C
. P
AD
H
YD
W V
H
YD
W V
W V
W V
W V
SM
H
R
IM
:6
.3
SM
H
R
IM
:6
.3
N . I
N V.
;6
.1
(1 2"
C
LA
Y)
S.
IN
V.
;6
.1
(1
2" C
LA
Y)
C O
EM
H
R
IM
;6
.6
EM
H
C B
R
IM
:6
.5
W . I
N V.
;6
.5
C B R
IM
:6
.7
(F U
LL
O
F D
EB
R
IS
GRASS
G R
AS
S
LANDSCAPING
LA
N
D
SC
AP
IN
G
LA
N
D
SC
AP
IN
G
BI
T.
PA
R
KI
N
G
LO
T
C O
636.0
638.0
636.5
636.0
636.0
635.5
634.5
634.0
633.5 632.5
637.5
637.5
637.5
637.0
636.5
637.5
PP
PPPP
PP
PP OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOE
W V
SMH
RIM:634.33
(UNABLE TO OPEN)
SA
SASASASASASASASASASASASA
ST
CONC. WALK
STSTSTST
ST
H
AN
D H
O
LE
LA
N
D
SC
AP
IN
G
LA
N
D
SC
AP
IN
G
6"
" 8"
PL
PL
PL
PL
PLPL
O E
O E
637.0
636.0
635.0
634.5
635.5
636.5
637.5
EX
. I
P.
1.
' E
EX
. R
EB
AR
0.
' E
CONC. WALK
635.0 E. LINE MICHIGAN AVENUE
GRANITE CURB
GRANITE CURB
C O
N C
. C U
R B
CONC. CURB
SMH
RIM:634.17
N. INV.;626.92 (12" CLAY)
S. INV.;626.92 (12" CLAY)
YD
R
IM
;6
.1
S.
IN
V.
;6
.7
(8
" P
VC
E.
IN
V.
;6
.6
(8
" P
VC
YD
R
IM
:6
.5
N . I
N V.
;6
.1
(8 " P
VC
S.
IN
V.
;6
.9
(8
" P
VC
C B
R
IM
:6
.9
N . I
N V.
;6
.9
(8 " H
D
PE
S.
IN
V.
;6
.7
(1
2" H
D
PE
E.
IN
V.
;6
.9
(6
" P
VC
BU
IL
D
IN
G C
O
LU
M N
(T
YP
WD. FNC.
WD. FNC.
CH. LINK FNC.
5' SETBACK
15' SETBACK
BENCHMARK: "X" MARK ON
BONNET BOLT ON HYDRANT
ELEV:637.45
EXIST. WATER MAIN
APPROX. LOCATION, NFV
636.5
637.0
637.5
633.0
ST
ST
ST ST ST ST
917 MICHIGAN
AVE.
PL
P L P L
PL PL
ST ST ST ST ST ST ST ST ST ST ST ST
EXIST. 30" RCP STORM SEWER, FROM RECORD
DRAWINGS, NFV
EXIST. 12" CLAY SAN. SEWER
EXIST. WALL MOUNTED ELECTRIC
METERS (4)
EXIST. 6" SMT STORM FOR
DOWNSPOUTS
(BASED ON RECORD DRAWINGS ONLY,
NFV)
EXTEND TEMPORARY
CONSTRUCTION FENCE TO EXIST.
SITE FENCE
166 MAPLE STREET LOT TO BE USED FOR CONTRACTOR
STORAGE. AREA HAS NOT BEEN SURVEYED OR FIELD VERIFIED.
CONTRACTOR TO PROVIDE TEMPORARY CONSTRUCTION FENCE
AND SILT FENCE AROUND PERIMETER.
3 2
CONTRACTOR TO REMOVE SECTION
OF CHAINLINK FENCE AS NEEDED
FOR ACCESS TO STORAGE AREA
STORE FENCING FOR RE-USE.
20 LF +/-
EXTEND STABILIZED
CONSTRUCTION ENTRANCE INTO
166 MAPLE STREET STORAGE
AREA. REFER TO 6/C-501
ALTERNATE #2 WORK AREA
CONTRACTOR TO PROTECT
EXISTING RODENT CONTROL WIRE
MESH ON PHASE 1 BUILDING
3CONTRACTOR SHALL AVOID BLOCKING ROADWAY
EXCEPT WHEN NECESSARY FOR CONSTRUCTION.
CONTRACTOR SHALL ENSURE THAT ROADWAY IS
OPEN BEFORE AND AFTER CONSTRUCTION
ACTIVITIES. NO CONSTRUCTION FENCING
ALLOWED IN ROADWAY.
9 CONTRACTOR TO PROTECT
EXISTING WALL MOUNTED
ELECTRIC METERS
CONTRACTOR TO LOCATE AND
PROTECT EXISTING STORM
EXPIRATION DATE:
BUFFALO OFFICE
50 ELK ST. STE 200
BUFFALO, NY 14210
FAX: 716.842.1807
ROCHESTER OFFICE
85 ALLEN ST. STE 310
ROCHESTER,NY 14608
FAX: 585.461.4771
PHONE: 716.842.1800
WWW.YOUNGANDWRIGHT.COM
12.31.2028
ROSWELL 907
COMMUNITY
OUTREACH AND
ENGAGEMENT
CENTER
PROJECT INFORMATION:
SHEET TITLE:
This is a single sheet of a cohesive set of construction documents, including drawings and specifications. Interpretation of information presented is to be based on the entire set of documents
Drawn By:
Project NO.:
Copyright 2026, Young Architectural, LLC
It is a violation of Title VIII, Arcticle 147 of NYS Education Law for any person, unless acting under direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to affix his or her seal and the notation
"altered by" followed by his or her signature and a specific description of the alterations made.
SHEET NUMBER:
CONSULTANTS:
STRUCTURAL ENGINEER
SIRACUSE ENGINEERS PC
MEP ENGINEER
ME ENGINEERING
CIVIL ENGINEER
WATTS ARCHITECTS AND ENGINEERS
716.206.5100
PR#: 2XXXX
PR#: 2XXXX
PR#: 20250675
08.10.2026ISSUE DATE:
REVISIONS:
REV. DATE DESCRIPTION
907 MICHIGAN AVE
BUFFALO, NY 14203
ROSWELL COMMUNITY
OUTREACH AND
ENGAGEMENT CENTER
PHASE 2
ADDITIONAL BUILDINGS:
APB
25103
R :\2
5\
R
PC
I O ut re ac h
En ga
\1 8.
C
AD
D \C iv \2
5_
D em o.
dw g Au g
, 2
6, :0 8p m
716.852.1894 EXT.116
716.845.5092
DASNY/BID SUBMISSION08.10.2026
CIVIL
DEMOLITION AND
ESC PLAN
C-101
SCALE: 1" = 10'1 CIVIL DEMOLITION AND EROSION AND SEDIMENTATION CONTROL PLAN
R :\2
5\
R
PC
I O ut re ac h
En ga
\1 8.
C
AD
D \C iv \2
5_
D em o.
dw g Au g
, 2
6, :0 8p m
EROSION CONTROL LEGEND (REFER TO C-501)
SYMBOLFEATURE/ DETAIL REF.KEY#
X
DEMOLITION GENERAL NOTES:
1. THE PURPOSE OF THIS PLAN IS TO IDENTIFY WHICH EXISTING SITE
IMPROVEMENTS ARE TO REMAIN AND WHICH ARE TO BE DEMOLISHED. THE
CONTRACTOR SHALL REVIEW THE DOCUMENTS IN THEIR ENTIRETY AND PERFORM
REMOVALS AS REQUIRED TO COMPLETE THE WORK.
2. THIS PLAN IS BASED ON EXISTING CONDITIONS TOPOGRAPHIC BASE MAPPING
FROM FIELD SURVEY BY 360 LAND SURVEY, DPC., FEBRUARY 19, 2026. SOME
UTILITIES HAVE BEEN ADDED BASED ON RECORD DRAWINGS. THE CONTRACTOR IS
RESPONSIBLE FOR FIELD VERIFICATION OF THE LOCATIONS AND DEPTHS OF ALL
EXISTING UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. CONTACT
UNDERGROUND FACILITY PROTECTION ORGANIZATION (UFPO) 1-800-962-7962 TWO
(3) FULL WORKING DAYS BEFORE EXCAVATION OPERATIONS.
4. COORDINATE START-UP AND ALL DEMOLITION ACTIVITIES WITH THE ARCHITACT
OR CONSTRUCTION MANAGER.
5. THE CONTRACTOR SHALL LOCATE MARK SAFEGUARD AND PRESERVE ALL SURVEY
CONTROL MONUMENTS IN THE AREAS OF DEMOLITION.
6. DEMOLITION SHALL BE KEPT WITHIN THE LIMITS SHOWN ON THE PLAN. THE
CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS AND VEGETATION
OUTSIDE THE LIMITS OF DEMOLITION.
DEMOLITION NOTES:
1. PAVEMENT DEMOLITION SHALL INCLUDE REMOVAL AND DISPOSAL OF EXISTING
BASE MATERIAL DOWN TO EXISTING SUBGRADE.
2. EXISTING ASPHALT PAVEMENT TO BE REMOVED SHALL BE SAW-CUT AT THE LIMITS
AS SHOWN ON THE PLANS. IN AREAS OF NEW CURBS AND SIDEWALKS SAW-CUT
LIMITS SHALL BE A MINIMUM OF 1-FOOT CLEARANCE OUTSIDE OF NEW CURB OR
SIDEWALK LINES (TYPICAL). ANY ADDITIONAL PAVEMENT REMOVAL FOR THE
CONVENIENCE OF THE CONTRACTOR SHALL BE REPLACED AT CONTRACTOR'S
EXPENSE.
3. ALL EXISTING CONCRETE TO BE REMOVED SHALL BE SAW CUT AT THE NEAREST
JOINT, OR REMOVED AND REPLACED AT THE NEAREST EXPANSION JOINT AS
NECESSARY, (COORDINATE WITH THE ARCHITECT).
4. EXISTING SITE FURNISHINGS TO BE REMOVED SHALL BE DISMANTLED AND
TEMPORARILY STORED ON-SITE FOR REUSE AS DIRECTED BY THE CONSTRUCTION
MANAGER OR ARCHITECT. ALL SITE FURNISHINGS NOT TO BE REUSED SHALL BE
DISPOSED OF BY THE CONTRACTOR.
5. EXISTING UNDERGROUND FACILITIES TO BE REMOVED SHALL BE EXCAVATED AND
COMPLETELY REMOVED DOWN TO SUITABLE BEDDING MATERIAL OR SUBGRADE.
ALL EXCAVATIONS OR VOIDS SHALL BE BACKFILLED AND COMPACTED WITH
APPROVED EARTH OR SELECT MATERIAL AS SPECIFIED.
6. ALL EXISTING UNDERGROUND PIPES TO BE ABANDONED IN PLACE SHALL BE
FILLED, CAPPED OR PLUGGED IN AN APPROVED MANNER.
7. ALL SITE DEMOLITION SHALL BE IN CONFORMANCE WITH THE PROJECT MANUAL
AND TECHNICAL SPECIFICATIONS, SECTIONS ON SITE CLEARING AND SELECTIVE
DEMOLITION.
8. ALL DEMOLITION DEBRIS SHALL BE TRANSPORTED OFF-SITE AND LEGALLY
DISPOSED OF BY THE CONTRACTOR UNLESS DIRECTED OTHERWISE BY THE
OWNER OR CONSTRUCTION MANAGER. ALL TRANSPORTATION AND DISPOSAL
COSTS INCLUDING ANY NECESSARY PERMITS AND FEES SHALL BE INCLUDED IN
THE CONTRACT PRICE.
STORMWATER POLLUTION PREVENTION NOTES:
1.TAKE THE FOLLOWING STEPS TO PREVENT LITTER, CHEMICALS AND
DEBRIS FROM ENTERING STORM DRAINS AND DISCHARGES:
A. PROPERLY INSTALL AND MAINTAIN EROSION AND SEDIMENT
CONTROL DEVICES AS OUTLINED IN THE PROJECT DOCUMENTS
AND IN COMPLIANCE WITH THE LATEST EDITION OF THE NEW YORK
STATE STANDARDS AND SPECIFICATIONS FOR THE EROSION AND
SEDIMENT CONTROL.
B. PROPERLY CONTAIN AND DISPOSE OF MATERIALS USED ON SITE.
THE CONTRACTOR TO CONTACT THE NYSDEC SPILLS HOTLINE
(1-800-457-7362) IN THE EVENT A SPILL OCCURS DURING
CONSTRUCTION.
C. CLEAN UP SPILLS IMMEDIATELY TO MINIMIZE SAFETY HAZARDS
AND PREVENT SPREADING.
D. CONTROL LITTER BY SWEEPING AND PICKING IT UP DAILY.
E. IF POSSIBLE, DO NOT STORE FUEL OR PETROLEUM PRODUCTS ON
SITE. IF FUEL/PETROLEUM PRODUCTS ARE STORED ON SITE:
a. USE SECONDARY CONTAINMENT MEASURES.
b. HAVE EQUIPMENT ON SITE TO CONTAIN AND CLEAN UP
SPILLS IN FUEL STORAGE AREAS OR ON BOARD MAINTENANCE
AND FUELING VEHICLES.
c. CONTAIN AND CLEAN UP SPILLS IMMEDIATELY.
d. USE PREVENTATIVE MAINTENANCE FOR ON-SITE EQUIPMENT.
e. OVERSEE ALL FILLING OPERATIONS.
F. PRACTICE GOOD HOUSEKEEPING AND EDUCATE EMPLOYEES ON
POLLUTION PREVENTION MEASURES.
a. STORE MATERIALS AND CHEMICALS IN A NEAT AND ORDERLY
MANNER AND IN AREAS DESIGNATED FOR SUCH STORAGE.
b. ROUTINELY DISPOSE OF GARBAGE, RUBBISH, CONSTRUCTION WASTE AND SANITARY WASTE.
c. PROMPTLY CLEAN UP ANY SPILLS.
d. ALL POINTS OF CONSTRUCTION INGRESS AND EGRESS TO BE
PROTECTED TO PREVENT THE DEPOSITION OF MATERIALS
ONTO TRAVERSE PUBLIC THOROUGHFARE(S) EITHER BY
INSTALLING AND MAINTAINING A STABILIZED CONSTRUCTION
ENTRANCE OR BY WASHING VEHICLE WHEELS IN A SAFE
DISPOSAL AREA. MATERIALS DEPOSITED ONTO PUBLIC
THOROUGHFARE(S) TO BE REMOVED IMMEDIATELY. PROPER
PRECAUTIONS ARE TO BE TAKEN TO ENSURE THAT MATERIALS
DEPOSITED ONTO PUBLIC THOROUGHFARE(S) ARE REMOVED
SO THAT THEY DO NOT ENTER DRAINAGE SYSTEMS. SWEEPING
OF ROADS UTILIZED DURING CONSTRUCTION SHALL BE DONE
ON A DAILY BASIS AT A MINIMUM OR AS ORDERED BY THE
OWNER.
e. THE CONTRACTOR TO PROVIDE DUST CONTROL MEASURES
BEFORE DUST MIGRATES OFF-SITE. SITE CONTRACTOR TO
HAVE A WATER TRUCK OR OTHER ACCEPTABLE MEANS OF
CONTROLLING DUST AVAILABLE AT ALL TIMES.
f. PRODUCTS TO BE KEPT IN THEIR ORIGINAL CONTAINERS WITH
THE ORIGINAL MANUFACTURER'S LABEL.
g. SUBSTANCES ARE NOT TO BE MIXED WITH ONE ANOTHER
UNLESS RECOMMENDED BY THE MANUFACTURER.
h. WHENEVER POSSIBLE, PRODUCT IS TO BE USED UP OR
PACKAGES RESEALED BEFORE PROPER DISPOSAL OF
CONTENTS AND CONTAINERS OFF-SITE.
i. MANUFACTURERS' RECOMMENDATIONS FOR PROPER USE AND
DISPOSAL ARE TO BE FOLLOWED.
j. INSPECTION TO BE MADE FOR PROPER USE AND DISPOSAL
OF MATERIALS DURING PERIODIC INSPECTIONS AND RECORDED
ON THE INSPECTION REPORT FORM.
G. FOR CONSTRUCTION WASTE:
a. SELECT A DESIGNATED WASTE AREA.
b. PROVIDE AN ADEQUATE NUMBER OF CONTAINERS WITH LIDS
OR COVERS THAT CAN BE PLACED OVER CONTAINERS PRIOR
TO RAINFALL.
c. WHEN POSSIBLE, LOCATE CONTAINERS IN A COVERED AREA.
d. ARRANGE FOR WASTE COLLECTION PRIOR TO CONTAINER
OVERFLOW.
e. IF A CONTAINER DOES SPILL, CLEAN IT UP IMMEDIATELY.
f. CONSTRUCTION WASTE TO BE COLLECTED, REMOVED AND
DISPOSED OF IN AUTHORIZED DISPOSAL AREAS.
g. DISPOSAL METHODS TO MEET THE REQUIREMENTS OF
FEDERAL, STATE AND LOCAL AUTHORITIES.
2. UTILIZE THE POLLUTION PREVENTION MEASURES OUTLINES ABOVE
TO PREVENT POLLUTANTS FROM STORED MATERIALS FROM
REACHING THE STORMWATER CONVEYANCE DEVICES AND
DISCHARGES.
3. IF FIELD CONDITIONS RENDER THE EROSION AND SEDIMENT
CONTROL MEASURES INEFFECTIVE IN MINIMIZING POLLUTANTS FROM
STORMWATER DISCHARGES THEN THE OWNER SHALL UPDATE OR
AMEND THE CONTRACT DRAWINGS TO ADDRESS THE DEFICIENCY.
THE CONTRACTOR TO INSTALL/CONSTRUCT ANY NEW FACILITIES
WITHIN 24-HOURS OF NOTIFICATION AS A RESULT OF THE
MODIFICATIONS.
4. UPON FINAL STABILIZATION OF THE SITE, REMOVE TEMPORARY
EROSION AND SEDIMENT CONTROL DEVICES. REPLACE FAILING OR
UNSATISFACTORY MEASURES. CLEAN STORMWATER CATCH BASINS,
MANHOLES AND PIPING. AS NECESSARY.
BACK, TOP OF CURB ELEV. BC:
BITUMINOUS BIT.
BUILDING BLDG.
CATCH BASIN SQUARE CB
CATCH BASIN ROUND CB
CONCRETE CONC.
CONTROL POINT CP
CORNER COR.
DECIDUOUS TREE W/ DIA
DEED D.
DIAMETER DIA.
EAST E.
ELEVATION ELEV
ELECTRICAL MANHOLE EMH
EXISTING EX.
FENCE FNC.
FIRST FLOOR ELEVATION FFE:
HYDRANT HYD.
INVERT INV.
IRON PIPE IP.
LIBER L
LIGHTPOLE LP
MAP MP.
MEASURED MS.
NORTH N.
PAGE P.
POLYVINYL CHLORIDE PVC
PORCH PO.
POWER POLE PP
SANITARY SEWER CO
CLEAN OUT
SANITARY SEWER SMH
MANHOLE
SOUTH S.
SPOT ELEVATION
STORY STY.
TOP OF CURB TC:
TYPICAL TYP.
WATER VALVE WV
WEST W.
WITH W/
WOOD WD.
WOODFRAME W.F.
YARD DRAIN YD
DETAIL TOPOGRAPHIC LIMITS
FENCE LINE
MAJOR CONTOUR LINE (2.0')
MINOR CONTOUR LINE (0.5')
XXX
18"
0 L
AN
D
SU
RV
EY
SA
ST
OE
XXX
PLPROPERTY LINE
OVERHEAD ELECTRIC
SANITARY SEWER LINE
STORM SEWER LINE
REMOVALS
1. REMOVE AND DISPOSE OF CONCRETE SIDEWALK
2. REMOVE AND DISPOSE OF ASPHALT PAVEMENT
3. SAWCUT ASPHALT / SAWCUT CONCRETE SIDEWALK AT
NEAREST JOINT
4. REMOVE AND DISPOSE OF CONCRETE CURB
5. PROVIDE TEMPORARY CONSTRUCTION FENCE AND 10'
WIDE DOUBLE SWING GATE, TO BE REMOVED UPON
PROJECT COMPLETION
6. REMOVE WOODEN WALKWAY, RAILINGS, AND WALKWAY
FOUNDATION AT EXISTING BUILDING ENTRANCE
7. TOPSOIL STOCKPILE AND LAWN REMOVAL AS NECESSARY
8. REMOVE EXISTING SHRUBS
9. REMOVE EXISTING TREE
X
DEMO LEGEND:
CONTRACT LIMIT LINE
CONCRETE SIDEWALK REMOVAL
ASPHALT PAVEMENT REMOVAL
SAWCUT ASPHALT/ SAWCUT CONCRETE SIDEWALK AT
NEAREST JOINT
REMOVE AND DISPOSE OF CONCRETE CURB
TEMPORARY CHAINLINK CONSTRUCTION FENCE, TO BE
REMOVED UPON PROJECT COMPLETION; REFER TO
DETAIL 13/C-501
NEW SANITARY SEWER CLEANOUT (FOR ESC
COORDINATION, REFER TO C-121)
NEW STORM SEWER CLEANOUT (FOR ESC
COORDINATION, REFER TO C-121)
NEW CATCH BASIN (FOR ESC COORDINATION, REFER TO
C-121)
COMPOSITE SILT FENCE
REFER TO DETAIL 3/C-501
SEDIMENT LOG (PAVEMENT)
REFER TO DETAIL 4/C-501
INLET PROTECTION
REFER TO DETAIL 1 & 2/C-501
CONC.TRUCK WASHOUT BASIN
REFER TO DETAIL 5/C-501
STABILIZED CONSTRUCTION ENTRANCE
REFER TO DETAIL 6/C-501
AutoCAD SHX Text
FFE:638.08
AutoCAD SHX Text
FFE:638.04
AutoCAD SHX Text
TC:636.33
AutoCAD SHX Text
TC:635.97
AutoCAD SHX Text
BC:635.61
AutoCAD SHX Text
TC:635.54
AutoCAD SHX Text
FFE:638.22
AutoCAD SHX Text
TC:632.20
AutoCAD SHX Text
BC:631.84
AutoCAD SHX Text
TC:633.15
AutoCAD SHX Text
BC:632.72
AutoCAD SHX Text
BC:633.42
AutoCAD SHX Text
TC:633.85
AutoCAD SHX Text
BC:634.05
AutoCAD SHX Text
TC:634.48
AutoCAD SHX Text
TC:635.23
AutoCAD SHX Text
BC:634.83
AutoCAD SHX Text
BC:637.53
AutoCAD SHX Text
BC:637.48
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text
TC:637.99
AutoCAD SHX Text
TC:638.04
AutoCAD SHX Text
SCALE: 1''= 10'-0"
AutoCAD SHX Text
AutoCAD SHX Text 10'
AutoCAD SHX Text 10'
AutoCAD SHX Text 5'
AutoCAD SHX Text
%%UEXISTING LEGEND:
AutoCAD SHX Text
TC:000.00
AutoCAD SHX Text 000.00
AutoCAD SHX Text
BC:000.00
AutoCAD SHX Text E
AutoCAD SHX Text S
O
N C
. W
AL
K
C O
N C
. W
AL
K
C O
N C
. W
AL
K
COVERED
WD. PO.
8.
0'
6.2'
9.
3'
6.
6'
COVERED
CONC. PO.
CONC.
UTILITY PAD
14.7'
7.
2'
1 STY. W.F.
BUILDING #907
C O
N C
. P
AD
EM
H
R
IM
;6
.6
EM
H
GRASS
G R
AS
S
LANDSCAPING
LA
N
D
SC
AP
IN
G
BI
T.
PA
R
KI
N
G
LO
T
638.0
636.5
636.0
635.5
634.5
634.0
633.5 632.5
637.5
637.5
637.5
637.0
637.5
PP
PPPP
PP
PP OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOE
CONC. WALK
H
AN
D H
O
LE
LA
N
D
SC
AP
IN
G
LA
N
D
SC
AP
IN
G
PL
PL
P L
PL
PLPL
O E
O E
637.0
636.0
635.0
634.5
635.5
636.5
637.5
EX
. I
P.
1.
' E
EX
. R
EB
AR
0.
' E
635.0 E. LINE MICHIGAN AVENUE
GRANITE CURB
GRANITE CURB
C O
N C
. C U
R B
CONC. CURB
BU
IL
D
IN
G C
O
LU
M N
(T
YP
WD. FNC.
WD. FNC.
CH. LINK FNC.
5' SETBACK
15' SETBACK
BENCHMARK: "X" MARK ON
BONNET BOLT ON HYDRANT
ELEV:637.45
637.0
637.5
633.0
917 MICHIGAN
AVE.
PL
P L P L
PL PL
ALTERNATE #2 WORK AREA
2.00' TYP.
R2.50'
(60 LF +/-)
10.75'
4.00'
8.00'
4.00' TYP.
2.00' TYP.
4.00'
67.00' +/-
37.00'
R2.50'
73.00' +/-
103 LF +/-
7.42'
18.00' +/-
RESET CHAINLINK FENCE
20 LF +/-
CONTRACTOR TO REMOVE CONSTRUCTION ENTRANCE AND
FENCING IN STAGING AREA, UPON PROJECT COMPLETION.
RESTORE DAMAGED LAWN AREA WITH 6" NEW TOPSOIL IN
ESTABLISHED TURF, SLOPE TO DRAIN TOWARDS ROADWAY .
FINISHED GRADE SHALL BE 1/2" BELOW SIDEWALK TO ALLOW FOR
DRAINAGE.
LAWN/LANDSCAPE RESTORATION AS NEEDED,
MATCH EXISTING
BACKUP GENERATOR PAD
REFER TO E-SERIES DRAWINGS
4.00'
4.00'
17.00'
4.00'
6.50 TYP.
VRF PAD,
REFER TO M-SERIES DRAWINGS
(REMOVE EXISTING SOIL AND
INSTALL STONE MULCH
BETWEEN FENCES)
65.00' +/-
EXPIRATION DATE:
BUFFALO OFFICE
50 ELK ST. STE 200
BUFFALO, NY 14210
FAX: 716.842.1807
ROCHESTER OFFICE
85 ALLEN ST. STE 310
ROCHESTER,NY 14608
FAX: 585.461.4771
PHONE: 716.842.1800
WWW.YOUNGANDWRIGHT.COM
12.31.2028
ROSWELL 907
COMMUNITY
OUTREACH AND
ENGAGEMENT
CENTER
PROJECT INFORMATION:
SHEET TITLE:
This is a single sheet of a cohesive set of construction documents, including drawings and specifications. Interpretation of information presented is to be based on the entire set of documents
Drawn By:
Project NO.:
Copyright 2026, Young Architectural, LLC
It is a violation of Title VIII, Arcticle 147 of NYS Education Law for any person, unless acting under direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to affix his or her seal and the notation
"altered by" followed by his or her signature and a specific description of the alterations made.
SHEET NUMBER:
CONSULTANTS:
STRUCTURAL ENGINEER
SIRACUSE ENGINEERS PC
MEP ENGINEER
ME ENGINEERING
CIVIL ENGINEER
WATTS ARCHITECTS AND ENGINEERS
716.206.5100
PR#: 2XXXX
PR#: 2XXXX
PR#: 20250675
08.10.2026ISSUE DATE:
REVISIONS:
REV. DATE DESCRIPTION
907 MICHIGAN AVE
BUFFALO, NY 14203
ROSWELL COMMUNITY
OUTREACH AND
ENGAGEMENT CENTER
PHASE 2
ADDITIONAL BUILDINGS:
APB
25103
R :\2
5\
R
PC
I O ut re ac h
En ga
\1 8.
C
AD
D \C iv \2
5_
Si te
.d w g Au g
, 2
6, :0 9p m
716.852.1894 EXT.116
716.845.5092
DASNY/BID SUBMISSION08.10.2026
CIVIL SITE PLAN
C-111
SCALE: 1" = 10'1 CIVIL SITE PLAN
NEW WORK LEGEND:
CONTRACT LIMIT LINE
ALTERNATE #2 WORK AREA
BUILDING ADDITION
NEW CONCRETE SIDEWALK
NEW ASPHALT PAVEMENT
NEW WOODEN FENCE (MATCH EXISTING)
RESET CHAINLINK FENCE
NEW TREE PLANTING (1/C-502)
NEW SHRUB PLANTING (2/C-502)
LAWN RESTORATION
BIOSWALE
NEW CONCRETE CURB
STONE MULCH
GENERAL SITE WORK NOTES
1. COORDINATE START-UP AND ALL CONSTRUCTION ACTIVITIES WITH THE ARCHITECT AND OWNER.
2. CONSTRUCTION METHODS AND MATERIALS NOT SPECIFIED ON THESE PLANS ARE TO MEET OR EXCEED
THE STANDARD SPECIFICATIONS AS SPECIFIED IN THE CONTRACT PROJECT MANUAL.
3. ALL CONSTRUCTION IN LOCAL, COUNTY OR STATE RIGHT-OF-WAYS SHALL BE IN CONFORMANCE WITH
ALL REQUIREMENTS, RULES AND SPECIFICATIONS OF THE CORRESPONDING AGENCY. ALL WORK
PERMITS AND FEES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
4. THE CONTRACTOR SHALL CONDUCT THE WORK IN A MANNER THAT WILL INSURE, AS FAR AS
PRACTICABLE, THE LEAST OBSTRUCTION TO TRAFFIC AND SHALL PROVIDE FOR THE CONVENIENCE AND SAFETY OF THE GENERAL PUBLIC AND RESIDENTS ALONG AND ADJACENT TO HIGHWAYS IN THE
CONSTRUCTION AREA IN AN ADEQUATE AND SATISFACTORY MANNER.
5. THE CONTRACTOR SHALL MAINTAIN SERVICE OF ALL EXISTING SITE UTILITIES DURING CONSTRUCTION.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DISRUPTION OF UTILITY SERVICE AND DAMAGE TO EXISTING SITE FEATURES, INCLUDING UNDERGROUND UTILITIES, RESULTING FROM THEIR OPERATIONS
IN EXECUTION OF THE WORK.
6. THE CONTRACTOR SHALL LOCATE MARK SAFEGUARD AND PRESERVE ALL SURVEY CONTROL
MONUMENTS AND R.O.W MONUMENTS IN THE AREAS OF CONSTRUCTION.
7. REFERENCES TO N.Y.S.D.O.T. STANDARDS SHALL MEAN THE "STANDARD SPECIFICATIONS,
CONSTRUCTION AND MATERIALS, OFFICE OF ENGINEERING, NEW YORK STATE DEPARTMENT OF
TRANSPORTATION SEPTEMBER 1, 2025" WITH ALL CURRENT ADDENDA.
8. DEMOLITION, STAGING AND GRADING SHALL BE KEPT WITHIN THE CONTRACT LIMIT LINE AS SHOWN ON THE PLANS. CONTRACTOR SHALL PROTECT EXISTING TREES AND VEGETATION DESIGNATED TO BE
SAVED, BOTH INSIDE AND OUTSIDE THE CONTRACT LIMIT LINE.
9. THE CONTRACTOR SHOULD LOCATE ALL PERTINENT PROPERTY, EASEMENT AND/OR RIGHT OF WAY
LINES PRIOR TO COMMENCEMENT OF THE WORK. THE CONTRACTOR SHALL NOT TRESPASS OR
COMMENCE WORK ON OTHER PROPERTIES, EASEMENTS, OR RIGHT OF WAYS WITHOUT PROPERLY
NOTIFYING AND MEETING THE NECESSARY REQUIREMENTS OF THE PROPERTY OWNER OR
AUTHORIZED AGENCY.
SITE LAYOUT NOTES:
1. ALL SITE LAYOUT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. ALL COSTS FOR SITE
LAYOUT SHALL BE INCLUDED IN THE CONTRACT PRICE.
2. ALL SITE LAYOUT SHALL BE IN ACCORDANCE WITH THE PLANS. THE CONTRACTOR SHALL
VERIFY ALL GRADES, ELEVATIONS AND DIMENSIONS IN THE FIELD. ANY DISCREPANCIES
AND/OR CONFLICTS SHALL BE IMMEDIATELY REPORTED TO THE ARCHITECT AND ENGINEER
FOR RESOLUTION PRIOR TO CONTINUING WITH THE AFFECTED WORK.
3. ALL DIMENSIONS ARE TO THE FACE OF CURB UNLESS INDICATED OTHERWISE.
4. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS (BY OTHERS) FOR EXACT NUMBERS,
LOCATIONS AND DIMENSIONS OF VESTIBULE EXIT PORCHES, PRECISE BUILDING DIMENSIONS
AND EXACT LOCATIONS AND NUMBER OF BUILDING UTILITY ENTRANCES.
5. BUILDING DIMENSIONS AS SHOWN ARE NOT INTENDED FOR ACTUAL BUILDING LAYOUT.
SPECIFIC LAYOUT DIMENSIONS SHOULD UTILIZE THE ACTUAL BUILDING PLANS. ANY
DISCREPANCIES BETWEEN BUILDING PLANS AND THOSE INDICATED ON THESE PLANS
SHOULD BE REPORTED TO THE ARCHITECT AND ENGINEER PRIOR TO PROCEEDING WITH THE
WORK. THE CONTRACTOR SHOULD STAKE OUT AND VERIFY EACH OF THE DIMENSIONS
INDICATED PRIOR TO COMMENCEMENT OF WORK.
6. ALL NEW SIDEWALKS WIDTHS AS SHOWN ARE EXCLUSIVE OF INTEGRAL CURB UNLESS NOTED
OTHERWISE. SIDEWALK LOCATIONS TO BE COORDINATED WITH BUILDING ENTRANCES ON
ARCHITECTURAL PLANS.
BACK, TOP OF CURB ELEV. BC:
BITUMINOUS BIT.
BUILDING BLDG.
CATCH BASIN SQUARE CB
CATCH BASIN ROUND CB
CONCRETE CONC.
CONTROL POINT CP
CORNER COR.
DECIDUOUS TREE W/ DIA
DEED D.
DIAMETER DIA.
EAST E.
ELEVATION ELEV
ELECTRICAL MANHOLE EMH
EXISTING EX.
FENCE FNC.
FIRST FLOOR ELEVATION FFE:
HYDRANT HYD.
INVERT INV.
IRON PIPE IP.
LIBER L
LIGHTPOLE LP
MAP MP.
MEASURED MS.
NORTH N.
PAGE P.
POLYVINYL CHLORIDE PVC
PORCH PO.
POWER POLE PP
SANITARY SEWER CO
CLEAN OUT
SANITARY SEWER SMH
MANHOLE
SOUTH S.
SPOT ELEVATION
STORY STY.
TOP OF CURB TC:
TYPICAL TYP.
WATER VALVE WV
WEST W.
WITH W/
WOOD WD.
WOODFRAME W.F.
YARD DRAIN YD
DETAIL TOPOGRAPHIC LIMITS
FENCE LINE
MAJOR CONTOUR LINE (2.0')
MINOR CONTOUR LINE (0.5')
XXX
18"
0 L
AN
D
SU
RV
EY
SA
ST
OE
XXX
PLPROPERTY LINE
OVERHEAD ELECTRIC
SANITARY SEWER LINE
STORM SEWER LINE
QTY KEY BOTANICAL NAME COMMON NAME SIZE ROOT COMMENT
PLANT LEGEND
PG/MA
- BS BUXUS SEMPERVIRENS BOXWOOD 18" HT. MIN. No.3 cont SPACED 5' O.C
- PA PYRUS ARBUTIFOLIA RED CHOKE BERRY 18" HT. MIN. No.3 cont SPACED 5' O.C.
- HP HYDRANGEA PANICULATA 'BOBO' BOBO HARDY HYDRANGEA 15" HT. MIN. No.3 cont SPACED 3'-4' O.C.
HA/HP/BS/MS
11+/-
- CS CORNUS SERICEA RED TWIG DOGWOOD 18" HT. MIN. No.3 cont SPACED 5' O.C
- MS MISCANTHUS SINENSIS "LITTLE MISS" LITTLE MISS DWARF MAIDEN GRASS 15" HT. MIN. No.3 cont SPACED 3' O.C.
X
1. CONCRETE SIDEWALK (7,8/C-501)
2. ASPHALT PAVEMENT (10/C-501)
3. WOODEN FENCE (12/C-501)
4. BIOSWALE (3/C-502)
5. NEW CONCRETE CURB (11/C-501)
6. STONE MULCH (9/C-501)
DETAILS KEY:
X
1. LAWN RESTORATION
2. NEW SIGN, REFER TO A-SERIES DRAWINGS
3. MULCH PLANTING BED
ANNOTATION KEY:
BS/PA/PV/HA/HP/CS/MS
40+/-
- PV PANICUM VIRGATUM 'PRAIRIE SKY' PRAIRIE SKY SWITCHGRASS CLUMP No.3 cont SPACED 3'-4' OC
CS
PV
PLANTING NOTE:
MULTIPLE PLANT TYPES LISTED ON A SINGLE LINE INDICATE POSSIBLE PLANTING OPTIONS.
BOTTOM NUMBER INDICATES APPROXIMATE AMOUNT BASED ON SPACING. OWNER TO CONFIRM
PLANT TYPES AND CONFIGURATION.
- PG PICEA GLAUCA 'CONICA' DWARF ALBERTA SPRUCE 18" HT.MIN. No.3 cont SPACED 5' O.C.
- HA HYDRANGEA ARBORESCENS 'BLUSH' BLUSH SMOOTH HYDRANGEA 15" HT. MIN. No.3 cont SPACED 3'-4' O.C.
- MA MALUS X 'SNOWDRIFT' SNOWDRIFT FLOWERING CRABAPPLE 18" HT. MIN. No.3 cont SPACED 5' O.C.
BIOSWALE
PLANTING:
PG/MA
AutoCAD SHX Text
FFE:638.08
AutoCAD SHX Text
FFE:638.04
AutoCAD SHX Text
TC:636.33
AutoCAD SHX Text
TC:635.97
AutoCAD SHX Text
BC:635.61
AutoCAD SHX Text
TC:635.54
AutoCAD SHX Text
FFE:638.22
AutoCAD SHX Text
TC:632.20
AutoCAD SHX Text
BC:631.84
AutoCAD SHX Text
TC:633.15
AutoCAD SHX Text
BC:632.72
AutoCAD SHX Text
BC:633.42
AutoCAD SHX Text
TC:633.85
AutoCAD SHX Text
BC:634.05
AutoCAD SHX Text
TC:634.48
AutoCAD SHX Text
TC:635.23
AutoCAD SHX Text
BC:634.83
AutoCAD SHX Text
BC:637.53
AutoCAD SHX Text
BC:637.48
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
TC:637.99
AutoCAD SHX Text
TC:638.04
AutoCAD SHX Text
SCALE: 1''= 10'-0"
AutoCAD SHX Text
AutoCAD SHX Text 10'
AutoCAD SHX Text 10'
AutoCAD SHX Text 5'
AutoCAD SHX Text
%%UEXISTING LEGEND:
AutoCAD SHX Text
TC:000.00
AutoCAD SHX Text 000.00
AutoCAD SHX Text
BC:000.00
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text
SHRUBS
TREES
638.00
636.00
635.00 636.00
637.00
638.00
638.00
637.50
637.50
635.00
634.00 633.50
635.50
636.50
636.50
635.00
634.50
636.00 635.50
638.00
MICHIGAN AVENUE (66.0')
C O
N C
. W
AL
K
C O
N C
. W
AL
K
C O
N C
. W
AL
K
COVERED
WD. PO.
8.
0'
6.2'
9.
3'
6.
6'
COVERED
CONC. PO.
CONC.
UTILITY PAD
14.7'
7.
2'
1 STY. W.F.
BUILDING #907
C O
N C
. P
AD
H
YD
W V
W V
C O
EM
H
GRASS
G R
AS
S
LANDSCAPING
LA
N
D
SC
AP
IN
G
C O
638.0
636.5
636.0
635.5
634.5
634.0
633.5 632.5
637.5
637.5
637.5
637.0
637.5
PP
PP
PP
OEOEOEOEOEOEOEOEOEOEOEOEOEOEOE
W V
(U N
AB
LE
T O
O
PE
N
SMH
RIM:634.33
(UNABLE TO OPEN)
SASASASASASASASASASA CONC. WALK
STSTSTST
ST
H
AN
D H
O
LE
LA
N
D
SC
AP
IN
G
LA
N
D
SC
AP
IN
G
PL
PL
PL
637.0
636.0
635.0
634.5
635.5
636.5
637.5
EX
. I
P.
1.
' E
EX
. R
EB
AR
0.
' E
635.0
C O
N C
. C U
R B
CONC. CURB
SMH
RIM:634.17
N. INV.;626.92 (12" CLAY)
S. INV.;626.92 (12" CLAY)
YD
R
IM
;6
.1
S.
IN
V.
;6
.7
(8
" P
VC
E.
IN
V.
;6
.6
(8
" P
VC
YD
R
IM
:6
.5
N . I
N V.
;6
.1
(8 " P
VC
S.
IN
V.
;6
.9
(8
" P
VC
C B
R
IM
:6
.9
N . I
N V.
;6
.9
(8 " H
D
PE
S.
IN
V.
;6
.7
(1
2" H
D
PE
E.
IN
V.
;6
.9
(6
" P
VC
BU
IL
D
IN
G C
O
LU
M N
(T
YP
WD. FNC.
CH. LINK FNC.
5' SETBACK
15' SETBACK
BENCHMARK: "X" MARK ON
BONNET BOLT ON HYDRANT
ELEV:637.45
EXIST. WATER MAIN
APPROX. LOCATION, NFV
637.0
637.5
633.0
ST
ST
ST ST ST ST
917 MICHIGAN
AVE.
PL
P L P L
PL PL
ST ST ST ST ST ST ST ST
EXIST. 30" RCP STORM SEWER, FROM RECORD
DRAWINGS, NFV
EXIST. 12" CLAY SAN. SEWER
EXIST. WALL MOUNTED ELECTRIC
METERS (4)
EXIST. 6" SMT STORM FOR
DOWNSPOUTS
(BASED ON RECORD DRAWINGS ONLY,
NFV)
BIOSWALE,
REFER TO C-111
5.00' MIN. (TYP.)
NEW CATCH BASIN, CB-1
RIM: 634.00
E. 6" IN INV. 630.00
W. 6" OUT INV. 629.98
MIN. INV. AT BLDG TO
MAINTAIN 1.0% SLOPE:
6" INV. 630.10
EXIST. 4" WATER
ELEV. AT BLDG:
629.66 +/-
(FROM RECORD
DRAWINGS, NFV)
+/-12 LF 6" SICPP
@1.0 % MIN.
35 LF 6" SICPP
@ 1.0% MIN.
70 LF 4" PVC
(SDR-35)
@2.0% SLOPE MIN.
8 LF 4" PVC
(SDR-35)
@2.0% SLOPE MIN. MIN. INV. AT BUILDING TO
MAINTAIN 2.0% SLOPE:
4" INV. 631.93
6" SICPP OUTLET INV. 634.00
37 LF 6" SICPP
@1.0 % MIN.
6" SICPP INV. 634.37
6" SICPP INV. 635.23
SAN. C.O
CONNECT TO EXIST. STORM,
FIELD VERIFY EXISTING INV.
STORM C.O
8"x4" TAPPING SLEEVE AND
VALVE
4" DIA 45 DEGREE BENDS
+/- 87 LF 4" DI FIRE
PROTECTION LINE
STORM C.O
STORM C.O
86 LF 6" SICPP
@1.0 % MIN.
1.5' MIN. VERTICAL
SEPARATION BETWEEN
WATER AND SANITARY
4" GATE
VALVE
REFER TO PLUMBING
DRAWINGS FOR
CONTINUATION
6" INV. 627.20
EXIST. 30" INV. 626.08 +/-
CONTRACTOR TO LOCATE
AND PROTECT EXISTING
UTILITIES AT BUILDING
CORNER
4" INV. AT SAN CONNECTION:
630.55
7 LF 6" SICPP
@ 1.0% MIN.
STORM C.O
EX
IS
T.
2" S
AN
EX
IS
T.
" W
AT
ER
EX
IS
T.
0" S
T.
0.
' M
IN
1.
' M
IN
1.
' M
IN
. FINISHED GRADE
STORM C.O.
EXPIRATION DATE:
BUFFALO OFFICE
50 ELK ST. STE 200
BUFFALO, NY 14210
FAX: 716.842.1807
ROCHESTER OFFICE
85 ALLEN ST. STE 310
ROCHESTER,NY 14608
FAX: 585.461.4771
PHONE: 716.842.1800
WWW.YOUNGANDWRIGHT.COM
12.31.2028
ROSWELL 907
COMMUNITY
OUTREACH AND
ENGAGEMENT
CENTER
PROJECT INFORMATION:
SHEET TITLE:
This is a single sheet of a cohesive set of construction documents, including drawings and specifications. Interpretation of information presented is to be based on the entire set of documents
Drawn By:
Project NO.:
Copyright 2026, Young Architectural, LLC
It is a violation of Title VIII, Arcticle 147 of NYS Education Law for any person, unless acting under direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to affix his or her seal and the notation
"altered by" followed by his or her signature and a specific description of the alterations made.
SHEET NUMBER:
CONSULTANTS:
STRUCTURAL ENGINEER
SIRACUSE ENGINEERS PC
MEP ENGINEER
ME ENGINEERING
CIVIL ENGINEER
WATTS ARCHITECTS AND ENGINEERS
716.206.5100
PR#: 2XXXX
PR#: 2XXXX
PR#: 20250675
08.10.2026ISSUE DATE:
REVISIONS:
REV. DATE DESCRIPTION
907 MICHIGAN AVE
BUFFALO, NY 14203
ROSWELL COMMUNITY
OUTREACH AND
ENGAGEMENT CENTER
PHASE 2
ADDITIONAL BUILDINGS:
APB
25103
R :\2
5\
R
PC
I O ut re ac h
En ga
\1 8.
C
AD
D \C iv \2
5_
U til ity .d w g
Au g
, 2
6, :1
2p m
716.852.1894 EXT.116
716.845.5092
DASNY/BID SUBMISSION08.10.2026
CIVIL SITE
UTILITY PLAN
C-121
SCALE: 1" = 10'1 CIVIL SITE UTILITY PLAN
NEW WORK LEGEND:
CONTRACT LIMIT LINE
NEW SANITARY SEWER
NEW SANITARY SEWER CLEANOUT (C.O)
NEW STORM PIPE
NEW STORM CLEANOUT (C.O)
DOWNSPOUT LOCATION
(REFER TO A-SERIES DRAWINGS)
NEW CATCH BASIN
BIOSWALE (REFER TO C-111)
NEW FIRE PROTECTION WATER LINE
NEW WATER VALVE
NEW 4" PERFORATED SICPP UNDERDRAIN
R :\2
5\
R
PC
I O ut re ac h
En ga
\1 8.
C
AD
D \C iv \2
5_
U til ity .d w g
Au g
, 2
6, :1
2p m
GENERAL UTILITY CONSTRUCTION NOTES:
1. ALL EXISTING CONDITIONS HAVE BEEN SURVEYED OR DESIGNED BY OTHERS. NO WARRANTY
OF THE ACCURACY OF THE LOCATIONS OF EXISTING SITE IMPROVEMENTS BY OTHERS AS
SHOWN HEREON IS EXPRESSED OR IMPLIED BY WATTS ENGINEERS.
2. THE CONTRACTOR SHALL VERIFY ALL GRADES, ELEVATIONS AND DIMENSIONS IN THE FIELD.
ANY DISCREPANCIES AND/OR CONFLICTS WITH OTHER EXISTING OR PROPOSED
IMPROVEMENTS SHALL BE REPORTED TO THE ARCHITECT AND ENGINEER FOR RESOLUTION.
3. ALL CONSTRUCTION IN PUBLIC RIGHT-OF-WAYS SHALL BE IN CONFORMANCE WITH ALL
SPECIFICATIONS, RULES AND REGULATIONS OF THE CORRESPONDING AGENCY HAVING
JURISDICTION. ALL NECESSARY WORK PERMITS, TAP PERMITS, AND FEES SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR.
4. THE CONTRACTOR SHALL RESTORE ALL EXISTING SITE IMPROVEMENTS TO THEIR ORIGINAL
CONDITION AS NECESSARY INCLUDING EXISTING UTILITIES, LAWN AREAS, SIDEWALKS,
PAVEMENT, CURBS, SIGNS, FENCES, ETC.
5. THE CONTRACTOR SHALL MAINTAIN SERVICE OF ALL EXISTING SITE UTILITIES DURING
CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR ANY DISRUPTION OF UTILITY
SERVICES AND DAMAGE TO EXISTING SITE IMPROVEMENTS, INCLUDING UNDERGROUND
UTILITIES, RESULTING FROM THE OPERATIONS IN EXECUTION OF THE WORK.
6. IT IS THE CONTRACTOR'S RESPONSIBILITY TO SECURE THE WORK AREA AND PROVIDE SAFETY
BARRIERS AROUND ANY AREAS OF INCOMPLETE WORK. MINIMUM REQUIREMENTS SHALL BE
THAT ANY OPEN TRENCHES SHALL BE SURROUNDED BY CONTINUOUS FOUR-FOOT HIGH
ORANGE PLASTIC CONSTRUCTION BARRIER FENCING OR COVERED WITH 1-INCH THICK STEEL
PLATE.
7. WHERE EXCAVATIONS CROSS EXISTING UTILITIES THE CONTRACTOR SHALL PROVIDE
TEMPORARY SUPPORTS AS REQUIRED. TEMPORARY SUPPORTS SHALL BE REMOVED UPON
COMPLETION OF BACKFILLING AND COMPACTION.
8. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE DESIGN AND CONSTRUCTION OF STABLE
TEMPORARY TRENCHES INCLUDING UTILIZATION OF TEMPORARY SHEETING, BRACING AND
DEWATERING AS NECESSARY TO MAINTAIN TRENCH STABILITY AND SAFETY.
9. UTILITIES CONSTRUCTED IN FILL OR BACKFILL SHALL UTILIZE SELECT FILL MATERIAL
COMPACTED TO 95% OF MAXIMUM DENSITY AT +/- 2% OF THE OPTIMUM MOISTURE CONTENT AS
DETERMINED BY THE MODIFIED PROCTOR METHOD (ASTM D1557). FILL OR BACKFILL MATERIAL
SHALL BE PLACED PRIOR TO EXCAVATION OF UTILITY TRENCHES.
10. FINAL RESTORATION SHALL INCLUDE CLEARING OF DEBRIS FROM ALL EXISTING AND NEW
MANHOLES AND JET-FLUSHING OF ALL EXISTING AND NEW STORM AND SANITARY SEWER LINES
AFFECTED BY CONSTRUCTION.
BACK, TOP OF CURB ELEV. BC:
BITUMINOUS BIT.
BUILDING BLDG.
CATCH BASIN SQUARE CB
CATCH BASIN ROUND CB
CONCRETE CONC.
CONTROL POINT CP
CORNER COR.
DECIDUOUS TREE W/ DIA
DEED D.
DIAMETER DIA.
EAST E.
ELEVATION ELEV
ELECTRICAL MANHOLE EMH
EXISTING EX.
FENCE FNC.
FIRST FLOOR ELEVATION FFE:
HYDRANT HYD.
INVERT INV.
IRON PIPE IP.
LIBER L
LIGHTPOLE LP
MAP MP.
MEASURED MS.
NORTH N.
PAGE P.
POLYVINYL CHLORIDE PVC
PORCH PO.
POWER POLE PP
SANITARY SEWER CO
CLEAN OUT
SANITARY SEWER SMH
MANHOLE
SOUTH S.
SPOT ELEVATION
STORY STY.
TOP OF CURB TC:
TYPICAL TYP.
WATER VALVE WV
WEST W.
WITH W/
WOOD WD.
WOODFRAME W.F.
YARD DRAIN YD
DETAIL TOPOGRAPHIC LIMITS
FENCE LINE
MAJOR CONTOUR LINE (2.0')
MINOR CONTOUR LINE (0.5')
XXX
18"
0 L
AN
D
SU
RV
EY
SA
ST
OE
XXX
PLPROPERTY LINE
OVERHEAD ELECTRIC
SANITARY SEWER LINE
STORM SEWER LINE
WATER SERVICE NOTES:
1. ALL WATER LINES CONSTRUCTED UNDER PAVED AREAS SHALL BE BACKFILLED WITH
SELECT BACKFILL, PLACED IN UNIFORM LIFTS OF A MAXIMUM THICKNESS NOT EXCEEDING
A LOOSE MEASUREMENT OF SIX (6) INCHES AND MECHANICALLY COMPACTED.
2. ALL WATER MAIN CONSTRUCTION SHALL CONFORM TO THE AUTHORITY HAVING
JURISDICTION PLUMBING DEPT. REQUIREMENTS.
3. NEW WATERLINES SHALL BE INSTALLED TO MAINTAIN A MINIMUM 5 FEET HORIZONTAL AND
1.5 FEET VERTICAL SEPARATION FROM EXISTING AND PROPOSED SANITARY AND STORM
SEWERS.
4. ALL NEW WATER SERVICES SHALL BE PRESSURE TESTED, CLEANED, CHLORINATED,
FLUSHED AND BACTERIOLOGICALLY TESTED IN ACCORDANCE WITH AWWA C-600, SECTION
4 AND AWWA C-651 (EXCLUDING SECTION 5.1), LATEST REVISIONS. DISINFECTION SHALL
ALSO BE IN COMPLIANCE WITH AWWA C-651.
SCALE: 1" = 20'H; 1" = 5'V2 NEW STORM SEWER: BLDG TO EXISTING 30" STORM
AutoCAD SHX Text
FFE:638.08
AutoCAD SHX Text
FFE:638.04
AutoCAD SHX Text
TC:636.33
AutoCAD SHX Text
TC:635.97
AutoCAD SHX Text
BC:635.61
AutoCAD SHX Text
TC:635.54
AutoCAD SHX Text
FFE:638.22
AutoCAD SHX Text
TC:632.20
AutoCAD SHX Text
BC:631.84
AutoCAD SHX Text
TC:633.15
AutoCAD SHX Text
BC:632.72
AutoCAD SHX Text
BC:633.42
AutoCAD SHX Text
TC:633.85
AutoCAD SHX Text
BC:634.05
AutoCAD SHX Text
TC:634.48
AutoCAD SHX Text
TC:635.23
AutoCAD SHX Text
BC:634.83
AutoCAD SHX Text
BC:637.53
AutoCAD SHX Text
BC:637.48
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text
TC:637.99
AutoCAD SHX Text
TC:638.04
AutoCAD SHX Text
WV
AutoCAD SHX Text
SCALE: 1''= 10'-0"
AutoCAD SHX Text
AutoCAD SHX Text 10'
AutoCAD SHX Text 10'
AutoCAD SHX Text 5'
AutoCAD SHX Text
%%UEXISTING LEGEND:
AutoCAD SHX Text
TC:000.00
AutoCAD SHX Text 000.00
AutoCAD SHX Text
BC:000.00
AutoCAD SHX Text E
AutoCAD SHX Text S
WV
O
N C
. W
AL
K
C O
N C
. W
AL
K
C O
N C
. W
AL
K
COVERED
WD. PO.
8.
0'
6.2'
9.
3'
6.
6'
COVERED
CONC. PO.
CONC.
UTILITY PAD
14.7'
7.
2'
1 STY. W.F.
BUILDING #907
C O
N C
. P
AD
H
YD
W V
H
YD
W V
W V
SM
H
R
IM
:6
.3
SM
H
R
IM
:6
.3
N . I
N V.
;6
.1
(1 2"
C
LA
Y)
S.
IN
V.
;6
.1
(1
2" C
LA
Y)
C O
EM
H
R
IM
;6
.6
EM
H
C B
R
IM
:6
.5
W . I
N V.
;6
.5
C B R
IM
:6
.7
(F U
LL
O
F D
EB
R
IS
GRASS
G R
AS
S
LANDSCAPING
LA
N
D
SC
AP
IN
G
BI
T.
PA
R
KI
N
G
LO
T
C O
636.0
638.0
636.5
636.0
636.0
635.5
634.5
634.0
633.5 632.5
637.5
637.5
637.5
637.0
636.5
637.5
PP
PPPP
PP
PP OEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOEOE
W V
SMH
RIM:634.33
(UNABLE TO OPEN)
SA
SASASASASASASASASASASASA
ST
CONC. WALK
STSTSTST
ST
H
AN
D H
O
LE
LA
N
D
SC
AP
IN
G
LA
N
D
SC
AP
IN
G
PL
PL
P L
PL
PLPL
O E
637.0
636.0
635.0
634.5
635.5
636.5
637.5
EX
. I
P.
1.
' E
EX
. R
EB
AR
0.
' E
635.0 E. LINE MICHIGAN AVENUE
GRANITE CURB
GRANITE CURB
C O
N C
. C U
R B
CONC. CURB
SMH
RIM:634.17
N. INV.;626.92 (12" CLAY)
S. INV.;626.92 (12" CLAY)
YD
R
IM
;6
.1
S.
IN
V.
;6
.7
(8
" P
VC
E.
IN
V.
;6
.6
(8
" P
VC
YD
R
IM
:6
.5
N . I
N V.
;6
.1
(8 " P
VC
S.
IN
V.
;6
.9
(8
" P
VC
C B
R
IM
:6
.9
N . I
N V.
;6
.9
(8 " H
D
PE
S.
IN
V.
;6
.7
(1
2" H
D
PE
E.
IN
V.
;6
.9
(6
" P
VC
BU
IL
D
IN
G C
O
LU
M N
(T
YP
WD. FNC.
WD. FNC.
CH. LINK FNC.
5' SETBACK
15' SETBACK
BENCHMARK: "X" MARK ON
BONNET BOLT ON HYDRANT
ELEV:637.45
EXIST. WATER MAIN
APPROX. LOCATION, NFV
636.5
637.0
637.5
633.0
ST
ST
ST ST ST ST
917 MICHIGAN
AVE.
PL
P L P L
PL PL
ST ST ST ST ST ST ST ST ST ST ST ST
EXIST. 30" RCP STORM SEWER, FROM RECORD
DRAWINGS, NFV
EXIST. 12" CLAY SAN. SEWER
EXIST. WALL MOUNTED ELECTRIC
METERS (4)
EXIST. 6" SMT STORM FOR
DOWNSPOUTS
(BASED ON RECORD DRAWINGS ONLY,
NFV)
F.F.E: 638.08
F.G: 637.95
638.00
MATCH EXIST.
ELEV.
F.F.E: 638.08
636.00
MATCH EXIST.
ELEV.
635.00 636.00
F.G: 637.99
FG: 638.08
(AT BLDG. CORNER)
2%
SL
O
PE
637.00
F.G: 635.57
F.G: 637.63
FG: 638.08
(AT EXIST. DOOR)
F.G: 637.86
638.00
638.00 F.G: 637.91
4.50%
SLO
PE
637.50
637.50
1.
5%
SL
O
PE
1.
5%
SL
O
PE
1.5%
SLOPE
635.00
634.00 633.50
635.50 F.G: 635.59
636.50
636.50
635.00
634.50
636.00 635.50
F.G: 637.50
MATCH EXIST.
ELEV.
638.00 F.G: 637.57
F.G: 637.91 F.G: 637.85
MATCH EXIST. ELEV.
F.G: 637.66
F.G: 637.71
F.G: 637.77
F.G: 637.76
MATCH EXIST.
ELEV.
EXPIRATION DATE:
BUFFALO OFFICE
50 ELK ST. STE 200
BUFFALO, NY 14210
FAX: 716.842.1807
ROCHESTER OFFICE
85 ALLEN ST. STE 310
ROCHESTER,NY 14608
FAX: 585.461.4771
PHONE: 716.842.1800
WWW.YOUNGANDWRIGHT.COM
12.31.2028
ROSWELL 907
COMMUNITY
OUTREACH AND
ENGAGEMENT
CENTER
PROJECT INFORMATION:
SHEET TITLE:
This is a single sheet of a cohesive set of construction documents, including drawings and specifications. Interpretation of information presented is to be based on the entire set of documents
Drawn By:
Project NO.:
Copyright 2026, Young Architectural, LLC
It is a violation of Title VIII, Arcticle 147 of NYS Education Law for any person, unless acting under direction of a licensed architect, to alter any item on this document in any way. Any licensee who alters this document is required by law to affix his or her seal and the notation
"altered by" followed by his or her signature and a specific description of the alterations made.
SHEET NUMBER:
CONSULTANTS:
STRUCTURAL ENGINEER
SIRACUSE ENGINEERS PC
MEP ENGINEER
ME ENGINEERING
CIVIL ENGINEER
WATTS ARCHITECTS AND ENGINEERS
716.206.5100
PR#: 2XXXX
PR#: 2XXXX
PR#: 20250675
08.10.2026ISSUE DATE:
REVISIONS:
REV. DATE DESCRIPTION
907 MICHIGAN AVE
BU…