RFB951100-01 Post 13 Upper Parking Lot - Bid Drawings.pdf
PDF 6 MB Posted
- Attached to
- DPS Post 13 Upper Parking Lot Replacement
- Solicitation number
- RFB951100-01
- Issued by
- Harrison County, Iowa
About this file
Bid Drawings for DPS Post 13 Upper Parking Lot Replacement
These are construction bid drawings prepared by Bolton & Menk, Inc. for the Iowa Department of Administrative Services (DAS) for the replacement of the upper parking lot at the Department of Public Safety (DPS) Post 13 located at 1300 S. Grand Avenue, Mount Pleasant, Iowa. The project involves complete removal and replacement of approximately 1,309 square yards of existing driveway pavement, 90 square yards of sidewalk, and associated site improvements including drainage, grading, landscaping, signage, and stoop/storefront modifications. Key bid items include 1,307 square yards of 6-inch Portland cement concrete (PCC) pavement, 1,418 square yards of subgrade preparation, modified subbase installation, 4-inch and 6-inch PCC sidewalk construction, detectable warning surfaces, removal and replacement of stoop slab or foundation (base bid versus alternate A), downspout boot installation with 4-inch trenched tile drainage, pavement markings, traffic signage with posts, mailbox salvage and reinstallation, hydraulic seeding, and sodding of disturbed areas. The drawings include 12 sheets covering typical sections, details, quantity estimates, parking lot layout, grading and erosion control plans, jointing layout, and stoop/storefront replacement specifications. An optional pre-bid meeting is scheduled for May 12, 2026, at 10:00 am at the project site, with bid submission required by 2:00 pm on June 4, 2026, through the IMPACS procurement system, with bid opening at 3:00 pm the same day. Construction must be completed no later than October 16, 2026.
The drawings specify a C-4 PCC mix with minimum 4,000 PSI compressive strength at 28 days, with epoxy-coated reinforcement and detailed joint specifications including expansion joints, contraction joints, and tied joints. The project includes phased construction to maintain vehicular access to the lower parking lot throughout the work period, with temporary mailbox service and delivery signage required during construction. Existing utility locations are shown at Quality Level D (based on existing utility records) per CI/ASCE 38-02 standards, with contractors required to notify Iowa One Call (1-800-292-8989) and field-verify all subsurface utilities prior to construction. The project is exempt from Iowa Sales Tax, and Davis-Bacon Wages do not apply. Bidders are encouraged to utilize certified Targeted Small Businesses as subcontractors in accordance with Iowa Code Chapter 73. The estimated project quantities and bid items are detailed on sheet C.01, with estimate reference notes and descriptions provided on sheet C.02. All bidders must submit bid security equal to 5% of the total bid amount in the form of a bid bond, cashier's check, or certified check. The Iowa Department of Administrative Services reserves the right to reject any and all bids and waive irregularities in the bidding process.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
AA
DM
IN
_S T_
IA
\2
5X
0\
CA
D\
C3 D\
A0
1.
dw g 4/
/2
:1
6:
A M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF ADMINISTRATIVE SERVICES
DPS POST 13 - UPPER PARKING LOT REPLACEMENT
FAM
TJN
FAM
9511.000
0 ISSUED FOR BID 04/07/2026430 E GRAND AVENUE, SUITE 101
DES MOINES, IA 50309
Phone: (515) 259-9190
Email: DesMoines@bolton-menk.com www.bolton-menk.comR
TH
IS
S
HE
ET
S
ET
IS
IN
TE
N
DE
D
TO
B E
PL
O
TT
ED
IN
C
O
LO
R
A.01
TITLE SHEET
R
MOUNT PLEASANT, IA
DPS POST 13 - UPPER PARKING LOT REPLACEMENT
DAS PROJECT #9511.00
MAY, 2026
NOTE: EXISTING UTILITY INFORMATION SHOWN ON THIS
PLAN HAS BEEN PROVIDED BY THE UTILITY OWNER. THE
CONTRACTOR SHALL FIELD VERIFY EXACT LOCATIONS PRIOR
TO COMMENCING CONSTRUCTION AS REQUIRED BY STATE
LAW. NOTIFY IOWA ONE CALL 1-800-292-8989 OR 811
THE SUBSURFACE UTILITY INFORMATION IN THIS PLAN IS
UTILITY QUALITY LEVEL D UNLESS OTHERWISE NOTED. THIS
UTILITY LEVEL WAS DETERMINED ACCORDING TO THE
GUIDELINES OF CI/ASCE 38-02, ENTITLED "STANDARD
GUIDELINES FOR THE COLLECTION AND DEPICTION OF
EXISTING SUBSURFACE UTILITY DATA."
PROJECT LOCATION
MAP OF THE
CITY OF MOUNT PLEASANT
HENRY COUNTY, IA
IOWA DEPARTMENT OF ADMINISTRATIVE SERVICES
CONSTRUCTION PLANS FOR
THE 2026 EDITION OF THE "IOWA STATEWIDE URBAN
SPECIFICATIONS FOR PUBLIC IMPROVEMENTS".
MUTCD 2009 AS ADOPTED BY IOWA DEPARTMENT OF
TRANSPORTATION.
ALL APPLICABLE FEDERAL, STATE, AND LOCAL LAWS AND
ORDINANCES WILL BE COMPLIED WITHIN THE CONSTRUCTION
OF THIS PROJECT.
GOVERNING SPECIFICATIONS
HENRY COUNTY, IA
MY LICENSE RENEWAL DATE IS
PAGES OR SHEETS COVERED BY THIS SEAL:
LIC. NO. DATE:
MY LICENSE RENEWAL DATE IS
PAGES OR SHEETS COVERED BY THIS SEAL:
LIC. NO. DATE:
I OWAI OWAI OWA
LI
CE
NS
ED
PR
OFESSIONAL ENGINEER
I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS
PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION
AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER
UNDER THE LAWS OF THE STATE OF IOWA.
P28860
12/31/2027
SHEETS A.01 - R.01
FORREST A.
MARTINSON
P28860
FORREST A. MARTINSON
INDEX OF SHEETS
SHEET NUMBER SHEET TITLE REVISION ISSUE DATE
A.01 TITLE SHEET 0 04/07/2026
A.02 LEGEND 0 04/07/2026
B.01 TYPICAL SECTIONS 0 04/07/2026
B.02 TYPICAL DETAILS 0 04/07/2026
C.01 ESTIMATED PROJECT QUANTITIES 0 04/07/2026
C.02 ESTIMATE REFERENCE NOTES 0 04/07/2026
D.01 PARKING LOT LAYOUT 0 04/07/2026
D.02 PLAN & PROFILE - ENTRANCE DRIVE 0 04/07/2026
F.01 REMOVALS 0 04/07/2026
G.01 CONTROL POINTS & ALIGNMENT DATA 0 04/07/2026
J.01 STAGING 0 04/07/2026
L.01 JOINTING LAYOUT 0 04/07/2026
R.01 GRADING & EROSION CONTROL 0 04/07/2026
S.01 STOOP REPLACEMENT AND STOREFRONT MODIFICATIONS 0 04/07/2026
MY LICENSE RENEWAL DATE IS
PAGES OR SHEETS COVERED BY THIS SEAL:
LIC. NO. DATE:
MY LICENSE RENEWAL DATE IS
PAGES OR SHEETS COVERED BY THIS SEAL:
LIC. NO. DATE:
I OWAI OWAI OWA
LI
CE
NS
ED
PR
OFESSIONAL ENGINEER
I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS
PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION
AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER
UNDER THE LAWS OF THE STATE OF IOWA.
P25714
12/31/2026
SHEET S.01
CHRISTOPHER
L. MARTIN
P25714
CHRISTOPHER L. MARTIN
1300 S. GRAND AVE.
MT PLEASANT, IOWA 52641
04/20/2026
04/20/2026
/2
INDEX OF SHEETS
SHEET NUMBER SHEET TITLE REVISION ISSUE DATE
A.01 TITLE SHEET 0 04/27/2026
A.02 LEGEND 0 04/27/2026
B.01 TYPICAL SECTIONS 0 04/27/2026
B.02 TYPICAL DETAILS 0 04/27/2026
C.01 ESTIMATED PROJECT QUANTITIES 0 04/27/2026
C.02 ESTIMATE REFERENCE NOTES 0 04/27/2026
D.01 PARKING LOT LAYOUT 0 04/27/2026
D.02 PLAN & PROFILE - ENTRANCE DRIVE 0 04/27/2026
F.01 REMOVALS 0 04/27/2026
G.01 CONTROL POINTS & ALIGNMENT DATA 0 04/27/2026
J.01 STAGING 0 04/27/2026
L.01 JOINTING LAYOUT 0 04/27/2026
R.01 GRADING & EROSION CONTROL 0 04/27/2026
S.01 STOOP REPLACEMENT AND STOREFRONT MODIFICATIONS 0 04/27/2026
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
AA
DM
IN
_S T_
IA
\2
5X
0\
CA
D\
C3 D\
A0
1.
dw g 4/
/2
:1
6:
A M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF ADMINISTRATIVE SERVICES
DPS POST 13 - UPPER PARKING LOT REPLACEMENT
FAM
TJN
FAM
9511.000
0 ISSUED FOR BID 04/07/2026430 E GRAND AVENUE, SUITE 101
DES MOINES, IA 50309
Phone: (515) 259-9190
Email: DesMoines@bolton-menk.com www.bolton-menk.comR
TH
IS
S
HE
ET
S
ET
IS
IN
TE
N
DE
D
TO
B E
PL
O
TT
ED
IN
C
O
LO
R
A.02
LEGEND
EXISTING TOPOGRAPHIC SYMBOLS
GRADING INFORMATION
1:4
F F F F
E E E E
G G G G
XXXXXXXXXXXX
EXISTING PRIVATE UTILITY LINES
STORM SEWER RECTANGULAR CASTING
STORM SEWER CIRCULAR CASTING
STORM SEWER FLARED END / APRON
CURB BOX
FIRE HYDRANT
MANHOLE
WATER REDUCER
WATER BEND
PROPOSED TOPOGRAPHIC SYMBOLS
CLEANOUT
LIFT STATION
RIP RAP
OE OE OE OE
C C C C
DRAINAGE FLOW
BENCH
BUSH
CATCH BASIN CIRCULAR CASTING
CURB STOP
CATCH BASIN RECTANGULAR CASTING
SIGNAL CONTROL CABINET
CLEAN OUT
DRINKING FOUNTAIN
FLARED END / APRON
FLAG POLE
FUEL PUMP
GRILL
HANDICAP SPACE
HANDHOLE
FIRE HYDRANT
MAILBOX
MANHOLE-HEAT
MANHOLE-ELECTRIC
MANHOLE-GAS
MANHOLE-SANITARY SEWER
MANHOLE-STORM SEWER
MANHOLE-COMMUNICATION
MANHOLE-UTILITY
PEDESTRIAN PUSH BUTTON
PEDESTAL-ELECTRIC
PEDESTAL-COMMUNICATION
VALVE POST INDICATOR
PARKING METER
LIGHT POLE
POLE-UTILITY
POST
PICNIC TABLE
RAILROAD SIGNAL POLE
REGULATION STATION GAS
TREE-DECIDUOUS
SATELLITE DISH
SIGN TRAFFIC
WATER SPIGOT
IRRIGATION SPRINKLER HEAD
IRRIGATION VALVE BOX
TREE STUMP
TELEPHONE BOOTH
TRANSFORMER-ELECTRIC
TREE-DEAD
TRASH CAN
TRAFFIC SIGNAL
VALVE
WETLAND
WELL
TREE-CONIFEROUS
GUY WIRE ANCHOR
LIFT STATION
LIFT STATION CONTROL PANEL
MANHOLE-WATER
BASKETBALL POST
CULVERT END
SOIL BORING
G/L G/L
ABBREVIATIONS
A ALGEBRAIC DIFFERENCE
ADJ ADJUST
ALT ALTERNATE
B-B BACK TO BACK
BLDG BUILDING
BMP BEST MANAGEMENT PRACTICE
BR BEGIN RADIUS
BV BUTTERFLY VALVE
CB CATCH BASIN
C&G CURB AND GUTTER
CIP CAST IRON PIPE
CIPP CURED-IN-PLACE PIPE
CL CENTER LINE
CL. CLASS
CMP CORRUGATED METAL PIPE
C.O. CHANGE ORDER
COMM COMMUNICATION
CSP CORRUGATED STEEL PIPE
CLVT CULVERT
DIA DIAMETER
DIP DUCTILE IRON PIPE
DWY DRIVEWAY
E EXTERNAL CURVE DISTANCE
ESMT EASEMENT
ELEC ELECTRIC
ELEV/EL ELEVATION
EOF EMERGENCY OVERFLOW
ER END RADIUS
EX EXISTING
FES FLARED END SECTION
F-F FACE TO FACE
FF FINISHED FLOOR
F&I FURNISH AND INSTALL
FM FORCEMAIN
FO FIBER OPTIC
F.O. FIELD ORDER
GRAN GRANULAR
GRAV GRAVEL
GU GUTTER
GV GATE VALVE
HDPE HIGH DENSITY POLYETHYLENE
HH HANDHOLE
HMA HOT MIX ASPHALT
HP HIGH POINT
HWL HIGH WATER LEVEL
HYD HYDRANT
I INVERT
K CURVE COEFFICIENT
L LENGTH
LO LOWEST OPENING
LP LOW POINT
LT LEFT
MH MANHOLE
MIN MINIMUM
MR MID RADIUS
NIC NOT IN CONTRACT
NMC NON-METALLIC CONDUIT
NTS NOT TO SCALE
NWL NORMAL WATER LEVEL
OHW ORDINARY HIGH WATER LEVEL
PC POINT OF CURVE
PCC PORTLAND CEMENT CONCRETE
PE PERMANENT EASEMENT
PED PEDESTRIAN, PEDESTAL
PERF PERFORATED PIPE
PERM PERMANENT
PI POINT OF INTERSECTION
PL PROPERTY LINE
PRC POINT OF REVERSE CURVE
PT POINT OF TANGENT
PVC POLYVINYL CHLORIDE PIPE
PVMT PAVEMENT
R RADIUS
RCP REINFORCED CONCRETE PIPE
RET RETAINING
R/W RIGHT-OF-WAY
RSC RIGID STEEL CONDUIT
RT RIGHT
SAN SANITARY SEWER
SCH SCHEDULE
SERV SERVICE
SHLD SHOULDER
STA STATION
STD STANDARD
STM STORM SEWER
TC TOP OF CURB
TE TEMPORARY EASEMENT
TEMP TEMPORARY
TNH TOP NUT HYDRANT
TP TOP OF PIPE
TYP TYPICAL
VCP VITRIFIED CLAY PIPE
VERT VERTICAL
VPC VERTICAL POINT OF CURVE
VPI VERTICAL POINT OF INTERSECTION
VPT VERTICAL POINT OF TANGENT
WM WATERMAIN
WS WATER SERVICE
AC ACRES
CF CUBIC FEET
CV COMPACTED VOLUME
CY CUBIC YARD
EA EACH
EV EXCAVATED VOLUME
LB POUND
LF LINEAR FEET
LS LUMP SUM
LV LOOSE VOLUME
SF SQUARE FEET
SV STOCKPILE VOLUME
SY SQUARE YARD
UNDERGROUND FIBER OPTIC
UNDERGROUND ELECTRIC
UNDERGROUND GAS
UNDERGROUND COMMUNICATION
OVERHEAD ELECTRIC
OVERHEAD COMMUNICATION
OVERHEAD UTILITY
953.53
EXISTING CONTOUR MINOR
EXISTING CONTOUR MAJOR
PROPOSED CONTOUR MINOR
PROPOSED CONTOUR MAJOR
PROPOSED GRADING LIMITS / SLOPE LIMITS
PROJECT LIMITS
PROPOSED SPOT ELEVATION
RISE:RUN (SLOPE)
OC OC OC OC
OU OU OU OU
STORM SEWER OUTLET STRUCTURE
STORM SEWER OVERFLOW STRUCTURE
STA:5+67.19
980.87
TRAFFIC ARM BARRIER
VENT PIPE
TILE INLET
TILE RISER
SIREN
DRIVE-THRU MICROPHONE
METER
ACCESS GRATE
FILL PIPE
DOWN SPOUT
BIRD FEEDER
ANTENNA
AIR CONDITION UNIT
NOTE:
EXISTING UTILITY INFORMATION SHOWN ON THIS PLAN HAS BEEN PROVIDED BY THE UTILITY OWNER. THE CONTRACTOR SHALL FIELD VERIFY EXACT LOCATIONS PRIOR TO COMMENCING CONSTRUCTION AS REQUIRED BY STATE LAW. NOTIFY IOWA ONE CALL - 1-800-292-8989
THE SUBSURFACE UTILITY INFORMATION IN THIS PLAN IS UTILITY QUALITY LEVEL D UNLESS OTHERWISE NOTED. THIS UTILITY LEVEL WAS DETERMINED ACCORDING TO THE GUIDELINES OF CI/ASCE 38-02, ENTITLED "STANDARD GUIDELINE FOR INVESTIGATING AND DOCUMENTING
EXISTING UTILITIES".
UTILITIES IDENTIFIED WITH A QUALITY LEVEL OTHER THAN D:
LINE TYPES FOLLOW THE FORMAT: UTILITY TYPE - QUALITY LEVEL
EXAMPLE: UNDERGROUND GAS, QUALITY LEVEL A
UTILITY QUALITY LEVEL (A,B,C,D) DEFINITIONS CAN BE FOUND IN CI/ASCE 38-22.
UTILITY QUALITY LEVELS:
LEVEL D - INFORMATION COMES SOLELY FROM EXISTING UTILITY RECORDS.
LEVEL C - SURVEYING ABOVE GROUND UTILITY FACILITIES, SUCH AS MANHOLES, VALVE BOXES, ETC; AND CORRELATING THIS INFORMATION WITH
EXISTING UTILITY RECORDS.
LEVEL B - THE USE OF SURFACE GEOPHYSICAL TECHNIQUES TO DETERMINE THE EXISTENCE AND HORIZONTAL POSITION OF UNDERGROUND
UTILITIES.
LEVEL A - THE USE OF NONDESTRUCTIVE DIGGING EQUIPMENT AT HORIZONTAL AND VERTICAL POSITION OF UNDERGROUND UTILITIES, AS WELL
AS THE TYPE, SIZE, CONDITION, MATERIAL, AND OTHER CHARACTERISTICS.
G-A G-A
UTILITY MARKER
VALVE VAULT
WET WELL
YARD HYDRANTY
BARRICADE PERMANENT
TILE OUTLET
EXISTING UTILITY LINES
| FM | | FM |
> SS > > SS >
>> DT >> >> DT >>
>> ST >> >> ST >>
WM WM
WS WS WS WS
PROPOSED UTILITY LINES
> SS > > SS >
SURVEY SYMBOLS
> SSS > > SSS >
R/W R/W R/W
R/W R/W R/W
SURVEY LINES
o o o
PAVEMENT MARKING
AUTO SPRINKLER CONNECTION
WETLAND DELINEATED MARKER
CONTROLLED ACCESS
BOUNDARY
CENTERLINE
EXISTING EASEMENT LINE
PROPOSED EASEMENT LINE
EXISTING LOT LINE
PROPOSED LOT LINE
EXISTING RIGHT-OF-WAY
PROPOSED RIGHT-OF-WAY
SETBACK LINE
SECTION LINE
BUSH LINE
TREE LINE
GUARD RAIL
FENCE-DECORATIVE
FENCE
RETAINING WALL
PIPE CASING
WATER SERVICE
WATERMAIN
STORM SEWER DRAIN TILE
STORM SEWER
SANITARY SERVICE
SANITARY SEWER
FORCEMAIN
WATER TEE
WATER CROSS
WATER SLEEVE
WATER CAP / PLUG
WATER VALVE
EXISTING TOPOGRAPHIC LINES
QUARTER LINE
SIXTEENTH LINE
TRAFFIC SIGNS
BOLLARD
TEMPORARY EASEMENT
LIGHT POLE
VAULT
WW
BENCHMARK LOCATION
MONUMENT FOUND
CAST IRON MONUMENT
CONTROL POINT STONE MONUMENT
TRENCHLESS PIPE (PLAN VIEW)
TRENCHLESS PIPE (PROFILE VIEW)
ELECTRIC CAR CHARGE STATIONEV
H
F
CLVT
CO
B
B
AC
CP
L
C
E
G
H
U
S
D
W
MANHOLE-RECLAIMED WATERW
M
C
E
P
Y
WW
WS
V
V
U
TRASH
TILE
G
| FM | | FM |
> SS > > SS > > SS >
> SSS > > SSS >
WM WM
WS WS WS WS
>> ST >> >> ST >>
>> DT >> >> DT >>
WATER SERVICE
WATERMAIN
STORM SEWER DRAIN TILE
STORM SEWER
SANITARY SERVICE
SANITARY SEWER
FORCEMAIN
WR WR WR WR WR WR RECLAIMED WATER
/2
EXISTING PAVEMENT, 5-6.5", REFER TO
GEOTECH REPORT AND G.01 FOR LOCATIONS
1 EXISTING PAVEMENT
NOT TO SCALE
18"
7'
R7-8 SIGN
VAN
ACCESSIBLE
2" SQUARE STEEL
POST (14 GAUGE)
4'
R7-8b
FOR VAN ACCESSIBLE
SPACES ONLY
2-1/4" OUTER
SOCKET
(12 GAUGE)
BOTTOM OF 2"
SQUARE STEEL POST
2-1/4" OUTER SOCKET
TO BE 2-3" ABOVE
GRADE
4 SIGN INSTALLATION
NOT TO SCALE
RESERVED
PARKING
PAVEMENT, PCC, 6 INCH, CLASS C
12 INCH SUBGRADE PREPARATION
3 PAVEMENT, PCC, 6 INCH, CLASS C
NOT TO SCALE
SUBBASE, MODIFIED, 6 INCH
SIDEWALK, PCC, 4 INCH, CLASS C
2 SIDEWALK, PCC, 4 INCH, CLASS C
NOT TO SCALE
SUBBASE, MODIFIED, 4 INCH
5 CLASS 'A' SIDEWALK AT LANDING
NOT TO SCALE
2' DETECTABLE
WARNING
1.5% TARGET, 2.0% MAX
6 INCH CURB AT LANDING
SEE L.01 FOR TAPER ON RAMP
1/2" EXPANSION JOINT
AND POLYURETHANE SEALANT
SIDEWALK, PCC, 6 INCH
SUBBASE, MODIFIED, 4 INCH
PAVEMENT, PCC, 6 INCH
SUBBASE, MODIFIED, 6 INCH
12 INCH SUBGRADE PREPARATION
6 CLASS 'A' SIDEWALK AT RAMP
NOT TO SCALE
1.5% TARGET, 2.0% MAX SEE L.01 FOR TAPER ON RAMP1/2" EXPANSION JOINT
AND POLYURETHANE SEALANT
PCC, 6 INCH MIN.
SUBBASE, MODIFIED, 4 INCH
PAVEMENT, PCC, 6 INCH
SUBBASE, MODIFIED, 6 INCH
12 INCH SUBGRADE PREPARATION
7 CLASS 'A' SIDEWALK
NOT TO SCALE
1.5% TARGET, 2.0% MAX
1/2" EXPANSION JOINT
AND POLYURETHANE SEALANT
PCC, 4 INCH MIN.
SUBBASE, MODIFIED, 4 INCH
PAVEMENT, PCC, 6 INCH
SUBBASE, MODIFIED, 6 INCH
12 INCH SUBGRADE PREPARATION
TAPER2'
TAPER2'
1'
1'
DOWNSPOUT
BOOT ADAPTOR
EXISTING DOWNSPOUT,
LENGTH TO BE MODIFIED FOR
BOOT INSTALLATION.
CONTRACTOR TO VERIFY SIZE
PRIOR TO ORDERING BOOT.
CLEANOUT
2x MINIMUM CONCRETE ANCHOR BOLT
TO BRICK BUILDING. RUBBER SPACER OR
AS REQUIRED BY MANUFACTURER.
90 DEGREE SWEEP, OR
2x 45 DEGREE BENDS
4 INCH PVC TO DRAIN,
SEE PLANS FOR CONTINUATION
8 CASTIRON DOWNSPOUT BOOT
NOT TO SCALE
PARKING
VISITOR
R78PG SIGN
18"
7'
R7330 SIGN
2" SQUARE STEEL
POST (14 GAUGE)
4'
2-1/4" OUTER
SOCKET
(12 GAUGE)
BOTTOM OF 2"
SQUARE STEEL POST
2-1/4" OUTER SOCKET
TO BE 2-3" ABOVE
GRADE
9 SIGN INSTALLATION
NOT TO SCALE
CLEAN OUT 12" MINIMUM
ABOVE GRADE
12" MINIMUM COVER
ABOVE BOOT ADAPTOR
SEE PLANS FOR GRADE
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
AA
DM
IN
_S T_
IA
\2
5X
0\
CA
D\
C3 D\
B0
1.
dw g 4/
/2
:1
6:
A M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF ADMINISTRATIVE SERVICES
DPS POST 13 - UPPER PARKING LOT REPLACEMENT
FAM
TJN
FAM
9511.000
0 ISSUED FOR BID 04/07/2026430 E GRAND AVENUE, SUITE 101
DES MOINES, IA 50309
Phone: (515) 259-9190
Email: DesMoines@bolton-menk.com www.bolton-menk.comR
TH
IS
S
HE
ET
S
ET
IS
IN
TE
N
DE
D
TO
B E
PL
O
TT
ED
IN
C
O
LO
R
B.01
TYPICAL SECTIONS
T
See Detail A or B
'C'
CONTRACTION JOINT
4'' ± 1
16'' Saw CutJoint Sealant Material 4'' ± 18''
T/4 ± 1/4''.
A
A
Crack or Joint Line
DETAIL A
(Saw cut formed by conventional concrete sawing equipment.)
8'' to 5
16'' Saw CutJoint Sealant Material 4'' ± 18''
1 14'' ± 14''
Crack or Joint Line
A
A
DETAIL B
(Saw cut formed by approved early concrete sawing equipment.)
Bottom of Saw Cut Top of Curb Saw Cut
1 12''
Top of Slab Joint Sealant Material
T/4 ± 1/4''
'C'
JOINT IN CURB
(Match 'CT', 'CD', or 'C' joint in pavement.)
Pavement Edge 15'' min.9'' min.
T at 12'' Centers.
24'' Long #4 Tie Bar
'RT'
ABUTTING PAVEMENT JOINT
RIGID TIE
Hole Diameter 1/8'' Larger than Tie Bar
L
TT/2
L/2
BAR PLACEMENT
(Applies to all joints unless otherwise detailed.)
See Detail C
T
'B'
PLAIN JOINT
(Abutting Pavement Slabs)
DETAIL C
Joint Sealant Material 4'' ± 1
16'' Saw Cut
1 14'' ± 14'' Saw Cut
4'' ± 18''
Crack or Joint Line
A
A
2" to 34''
Top of Pavement Sealant
SECTION A-A
(Detail at Edge of Pavement)
T < 8'' 24'' Long at 30'' Centers
Joint Bars
'BT-5' #4
Bar Length and Spacing
T
9'' min. 15'' min.
of Joint not required3 4'' Dia. Hole for BT-3 and BT-4 Joint 8'' Dia. Hole for BT-5 Joint
'BT'
ABUTTING PAVEMENT JOINT - RIGID TIE (Drilled)
T
T < 8'' 36'' Long at 30'' Centers
Joint Bars 'L-1' #4
Bar Length and Spacing
CONTRACTION JOINT
See Detail D-2
'L-1' interchangeable with 'BT-1' subject to pouring sequence
Crack or Joint Line
T/3 ± 14''
Joint Sealant Material 4'' ± 1
16'' Saw Cut
DETAIL D-2
18'' Long 3/4" Dowel at 12'' Centers Width
(See Detail F)
T
'ED'
DOWELED EXPANSION JOINT
See Detail F, Predrill or preform holes in joint material for appropriate dowel size.
DETAIL F
8''
Joint Filler
2'' Joint Sealant Material15
Hole Diameter 1/8'' Larger than Dowel
Resilient Joint Filler
See Detail F
1'' Nominal 'E'
1'' EXPANSION JOINT
Edge with 1/8 inch tool for length of joint
Sawing and Sealing
'L'
Saw Cut
FORM
GRADE
ELEV.
Slope as per plans
2''
2''
6"
6" STANDARD CURB
R 3"
R 3"
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
AA
DM
IN
_S T_
IA
\2
5X
0\
CA
D\
C3 D\
B0
1.
dw g 4/
/2
:1
6:
A M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF ADMINISTRATIVE SERVICES
DPS POST 13 - UPPER PARKING LOT REPLACEMENT
FAM
TJN
FAM
9511.000
0 ISSUED FOR BID 04/07/2026430 E GRAND AVENUE, SUITE 101
DES MOINES, IA 50309
Phone: (515) 259-9190
Email: DesMoines@bolton-menk.com www.bolton-menk.comR
TH
IS
S
HE
ET
S
ET
IS
IN
TE
N
DE
D
TO
B E
PL
O
TT
ED
IN
C
O
LO
R
B.02
TYPICAL DETAILS
NOTES:
1. JOINT DETAILS SHOWN ARE PROJECT SPECIFIC SUDAS DETAILS AS
REFERRED TO ON SHEET D.02
2. CHANGES IN CONSTRUCTION ACTIVITIES MAY REQUIRE THE
IMPLEMENTATION OF OTHER JOINT DETAILS.
3. REFER TO 7010.101 (PV-101) FOR FULL LIST OF SUDAS JOINT DETAILS
4. REFER TO 7010.102 (PV-102) FOR FULL LIST OF SUDAS CURB DETAILS
ESTIMATED PROJECT QUANTITIES (ALTERNATE A)
ITEM NO. ITEM CODE ITEM UNIT QUANTITY AS-BUILT QTY.
A1 7030-999-A REMOVAL OF STOOP FOUNDATION, INSTALL STOOP FOUNDATION AND SLAB LS 1
ESTIMATED PROJECT QUANTITIES - BASE BID
ITEM NO. ITEM CODE ITEM UNIT QUANTITY AS-BUILT QTY.
1 2010-C CLEARING, GRUBBING, AND LANDSCAPE REMOVALS LS 1
2 2010-D-1 TOPSOIL, ON-SITE CY 161
3 2010-E EXCAVATION, CLASS 10 CY 210
4 2010-G SUBGRADE PREPARATION SY 1418
5 2010-J SUBBASE, MODIFIED, 6 INCHES SY 1418
6 4020-E-1 TILE, TRENCHED, 4 INCH LF 60
7 4020-999-A DOWNSPOUT BOOT, CASTIRON LS 1
8 7010-A PAVEMENT, PCC, 6 INCH, C4-WR-C20 SY 1307
9 7030-A-1 REMOVAL OF SIDEWALK SY 90
10 7030-E SIDEWALK, PCC, 4 INCH SY 59
11 7030-E SIDEWALK, CLASS 'A', PCC, 6 INCH SY 39
12 7030-G DETECTABLE WARNING SF 12
13 7030-999-A REMOVAL OF STOOP SLAB LS 1
14 7030-999-A REPLACE STOOP SLAB ON EXISTING STOOP FOUNDATION LS 1
15 7040-H PAVEMENT REMOVAL SY 1309
16 8020-B PAINTED PAVEMENT MARKINGS, SOLVENT/WATERBORNE STA 2
17 8020-G PAINTED SYMBOLS AND LEGENDS, WATERBORNE OR SOLVENT EA 1
18 8040-A TRAFFIC SIGNS, ADA EA 1
19 8040-A TRAFFIC SIGNS, VISITOR, 12X18 EA 2
20 8040-D PERFORATED SQUARE STEEL TUBE POSTS LF 30
21 8040-G PERFORATED SQUARE STEEL TUBE POSTS ANCHORS, BREAKAWAY, 2 INCH EA 3
22 8040-I REMOVE SIGNS EA 4
23 8040-999-X SALVAGE AND REINSTALL MAILBOX EA 1
24 9010-B HYDRAULIC SEEDING, SEEDING, FERTILIZING, AND MULCHING, TYPE 1 - PERMANENT LAWN AC 0.3
25 9020-A SOD SY 230
26 9040-F-1 WATTLE, COMPOST/MULCH SOCK LF 1000
27 9040-F-2 WATTLE, REMOVAL LF 1000
28 11010-A CONSTRUCTION SURVEY LS 1
29 11020-A MOBILIZATION LS 1
30 11030-A MAINTENANCE OF POSTAL SERVICE LS 1
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
AA
DM
IN
_S T_
IA
\2
5X
0\
CA
D\
C3 D\
C0
1.
dw g 4/
/2
:1
7:
A M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF ADMINISTRATIVE SERVICES
DPS POST 13 - UPPER PARKING LOT REPLACEMENT
FAM
TJN
FAM
9511.000
0 ISSUED FOR BID 04/07/2026430 E GRAND AVENUE, SUITE 101
DES MOINES, IA 50309
Phone: (515) 259-9190
Email: DesMoines@bolton-menk.com www.bolton-menk.comR
TH
IS
S
HE
ET
S
ET
IS
IN
TE
N
DE
D
TO
B E
PL
O
TT
ED
IN
C
O
LO
R
C.01
QUANTITIES
ESTIMATE REFERENCE INFORMATION
ITEM NO. ITEM
CODE DESCRIPTION
1 2010-C CLEARING, GRUBBING, AND LANDSCAPE REMOVALS
SEE SHEET F.01.
THIS ITEM INCLUDES THE REMOVAL AND LAWFUL DISPOSAL OF LANDSCAPE EDGER, RETAINGWALL BRICK, ROCK MULCH, AND PLANT MATERIAL AS IDENTIFIED ON SHEET F.01, AND REMOVAL AND REINSTALLATION OF THESE ITEMS AS REQUIRED FOR CONSTRUCTION OF OTHER ELEMENTS
IN THIS PROJECT.
ALL LANDSCAPING NOT IDENTIFIED FOR REMOVAL SHALL BE PROTECTED.
2 2010-D-1 TOPSOIL, ON-SITE
TOPSOIL WITHIN THE GRADING LIMITS OF THE PROJECT SHALL BE STRIPPED AT A MINIMUM OF 8", SALVAGED, AND RESPREAD AT A MINIMUM DEPTH OF 6". ITEM INCLUDES HAULING OFF-SITE TO STORE AND HAULING BACK IN IF NEEDED. SALVAGED TOPSOIL SHALL REMAIN WITHIN THE RIGHT-OF-WAY UNLESS AGREEMENTS MADE WITH THE PROPERTY OWNER. CONTRACTOR IS RESPONSIBLE FOR RESTORATION COST IF OUTSIDE
OF GRADING LIMITS.
QUANTITIY IS CALCULATED BASED ON AREA OF DISTRUBANCE 6500 SF, AT A DEPTH OF 8" OF TOPSOIL TO BE SALVAGED. THIS ITEM SHALL BE
PAID ON A PERCENT COMPLETE BASIS, AND NO MEASUREMENT WILL BE MADE.
3 2010-E EXCAVATION, CLASS 10
THIS ITEM SHALL INCLUDE THE REMOVAL OF EXISTING SOIL, HAULING, DISPOSAL/EXPORT AND RE-GRADING AS NEEDED PER PLAN TO FACILITATE ALL PROPOSED SECTIONS. ALL BORROW SHALL BE PROVIDED BY THE CONTRACTOR. EXCESS OR UNSUITABLE EXCAVATED MATERIAL WILL BECOME PROPERTY OF THE CONTRACTOR AND WILL BE HAULED OFF-SITE INCIDENTAL TO THE ITEM. NO ADDITIONAL PAYMENT WILL BE ALLOWED FOR OVERHAUL OF WASTE. TOPSOIL SHALL BE PLACED AND SPREAD TO A MINIMUM THICKNESS OF 6" IN ALL DISTURBED TURF
AREAS AND PAID FOR AS TOPSOIL, ON-SITE.
RAW CUT = 77 CY, RAW FILL = 212 CY, ADJUSTED FILL (1.35 FACTOR) = 287 CY
NET EARTHWORK = 210 CY
RAW EARTHWORK QUANTITIES ARE FOR INFORMATIONAL PURPOSES ONLY ARE A COMPARISON OF EXISTING CONDITIONS AND PROPOSED CONDITIONS AND MAY INCLUDE MATERIALS AND OPERATIONS PAID FOR UNDER OTHER BID ITEMS E.G. PAVEMENT REMOVAL, STORM SEWER TRENCHED, PCC PAVEMENT, SUBBASE, TOPSOIL, COMPOST AMENDMENT, ETC. MEASUREMENT WILL NOT BE MADE AND QUANTITY PAID WILL
BE ON A PERCENT OF ITEM COMPLETE.
4 2010-G SUBGRADE PREPARATION
CONTRACTOR SHALL PROOF ROLL THE EXISTING SUBGRADE IMMEDIATELY FOLLOWING REMOVAL OF PAVEMENT TO IDENTIFY YIELDING SOILS PER THE GEOTECHNICAL REPORT'S RECOMMENDATION. UNSUITABLE SOILS SHALL BE REMOVED AND HAULED OFF SITE AND REPLACED WITH SUITABLE SOILS FROM ON-SITE. FOLLOWING PROOFROLLING SUBGRADE SHALL BE SCARIFIED, MOISTURE CONDITIONED, GRADED, AND
COMPACTED.
5 2010-J SUBBASE, MODIFIED, 6 INCHES
THIS ITEM INCLUDES, BUT IS NOT LIMITED TO, COMPACTION OF SUBGRADE, FURNISHING, PLACING, COMPACTING, AND TRIMMING TO THE
PROPER GRADE.
6 4020-E-1 TILE, TRENCHED, 4 INCH
THIS ITEM IS FOR CONNECTION THE DOWNSPOUT BOOT TO THE EXISTING PIPE AS SHOWN ON SHEET D.01. PIPE MATERIALS SHALL COMPLY WITH SUDAS 4020 2.01E POLYVINYL CHLORIDE PIPE, OR 2.01F HIGH DENSITY POLYETHYLENE PIPE.
NATIVE BACKFILL SHALL BE FREE OF MATERIAL COULD DAMAGE THE PIPE.
7 4020-999-A DOWNSPOUT BOOT, CASTIRON
CONTRACTOR SHALL FIELD VERIFY DOWNSPOUT SIZE PRIOR TO SUBMITTING PRODUCT TO ENGINEER FOR ACCEPTANCE. SEE DETAIL 8/B.01
8 7010-A PAVEMENT, PCC, 6 INCH, C4-WR-C20
CONCRETE SHALL BE A C-4 MIX WITH A MINIMUM COMPRESSIVE STRENGTH OF 4,000 PSI AT 28 DAYS. SLAG IS NOT ALLOWED. CURB AND GUTTER SECTION IS INCLUDE IN THE AREA OF THIS ITEM AND SHALL BE INCIDENTAL TO PAVEMENT CONSTRUCTION. REINFORCEMENT SHALL BE EPOXY COATED. 6 INCH MODIFIED SUBBASE SHALL BE PLACED UNDER THE PAVEMENT AND IS PAID FOR UNDER A SEPARATE BID ITEM. NO ADDITIONAL PAYMENT FOR COLD WEATHER PAVING OPERATIONS. FINAL TRIMMING OF SUBGRADE OR SUBBASE, INTEGRAL CURB, BARS AND REINFORCEMENT, JOINTS AND SEALING, SURFACE CURING AND PAVEMENT PROTECTION, SAFETY FENCING, CONCRETE FOR RIGID HEADERS, AND BOXOUTS FOR FIXTURES SHALL BE INDICENTAL TO THIS ITEM.
9 7030-A-1 REMOVAL OF SIDEWALK
ALL REMOVALS TO BE MARKED AND MEASURED BY THE ENGINEER. FULL DEPTH SAW CUTS ALONG THE REMOVAL LIMITS ARE INCIDENTAL TO THIS ITEM. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADDITIONAL REMOVAL, EARTHWORK, SUBGRADE PREPARATION, MODIFIED SUBBASE AND PAVING EXPENSES DUE TO DAMAGED EDGES. ADDITIONAL REMOVAL TO BE DETERMINED BY ENGINEER. PAYMENT SHALL BE
MADE FOR THE AREA OF PAVEMENT REMOVED REGARDLESS OF THICKNESS.
10 7030-E SIDEWALK, PCC, 4 INCH
CONCRETE WILL BE C OR M MIX WITH A MINIMUM COMPRESSIVE STRENGTH OF 4,000 PSI AT 28 DAYS. SLAG IS NOT ALLOWED. COMPACTION OF SUBGRADE IS INCIDENTAL TO THIS ITEM. CONCRETE TESTING WILL BE PROVIDED BY THE OWNER. NO EXTRA PAYMENT FOR COLD WEATHER
PAVING.
11 7030-E SIDEWALK, CLASS 'A', PCC, 6 INCH
CONCRETE WILL BE C OR M MIX WITH A MINIMUM COMPRESSIVE STRENGTH OF 4,000 PSI AT 28 DAYS. SLAG IS NOT ALLOWED. COMPACTION OF SUBGRADE IS INCIDENTAL TO THIS ITEM. CONCRETE TESTING WILL BE PROVIDED BY THE OWNER. NO EXTRA PAYMENT FOR COLD WEATHER
PAVING.
12 7030-G DETECTABLE WARNING
DETECTABLE WARNINGS SHALL MEET CURRENT PROWAG STANDARDS.
13 7030-999-A REMOVAL OF STOOP SLAB
CONTRACTOR SHALL DEMOLISH EXISTING STOOP SLAB AND COORDINATE WITH ENGINEER TO EVALUATE CONDITION OF EXISTING STOOP FOUNDATION WALLS. IF EXISTING FOUNDATION WALLS APPEAR TO BE APPROPRIATELY SIZED AND CONSTRUCTED OF SOUND CONCRETE CAPABLE OF RECEIVING NEW DOWELS, CONTRACTOR SHALL REPLACE STOOP SLAB ON EXISTING STOOP FOUNDATION.
IF FOUNDATION IS FOUND INAPPROPRIATE FOR REUSE, ALTERNATE A SCOPE WILL BE REQUIRED.
STOREFRONT THRESHOLD, STOREFRONT CAULKING, AND DOOR OPENER PEDESTAL REPLACEMENT ARE REQUIRED FOR EITHER SCOPE OF WORK
AND IS INCLUDED IN THIS ITEM.
14 7030-999-A REPLACE STOOP SLAB ON EXISTING STOOP FOUNDATION
FOLLOWING EVALUATION OF THE EXISTING STOOP FOUNDATION WALLS AND AS DIRECTED BY ENGINEER:
CONTRACTOR SHALL DRILL AND EPOXY INDICATED BENT DOWELS INTO EXISTING STOOP FOUNDATION WALLS AND REPLACE STOOP SLAB AS
INDICATED ON SHEET S.01
IF ALTERNATE A ITEM IS REQUIRED, THIS ITEM WILL BE REMOVED FROM CONTRACT.
15 7040-H PAVEMENT REMOVAL
CONTRACTOR SHALL PROTECT EXISTING PAVEMENT TO REMAIN. CONTRACTOR SHALL REPLACE PAVEMENT DAMAGED DURING CONSTRUCTION
AT NO ADDITIONAL COST.
16 8020-B PAINTED PAVEMENT MARKINGS, SOLVENT/WATERBORNE
CONTRACTOR SHALL REMOVE SURFACE CURE PRIOR TO INSTALLING PAVEMENT MARKINGS. REFLECTORIZING GLASS SPHERES SHALL BE
INSTALLED WITH ALL PAVEMENT MARKINGS.
17 8020-G PAINTED SYMBOLS AND LEGENDS, WATERBORNE OR SOLVENT
CONTRACTOR SHALL REMOVE SURFACE CURE PRIOR TO INSTALLING PAVEMENT MARKINGS. REFLECTORIZING GLASS SPHERES SHALL BE
INSTALLED WITH ALL PAVEMENT MARKINGS.
18 8040-A TRAFFIC SIGNS, ADA
SEE DETAIL 4/B.01.
THIS ITEM SHALL BE FOR SIGN R7-8 AND PLAQUE R78PG.
19 8040-A TRAFFIC SIGNS, VISITOR, 12X18
SEE DETAIL 9/B.01
20 8040-D PERFORATED SQUARE STEEL TUBE POSTS
SEE DETAIL 4/B.01 AND 9/B.01
21 8040-G PERFORATED SQUARE STEEL TUBE POSTS ANCHORS, BREAKAWAY, 2 INCH
SEE DETAIL 4/B.01 AND 9/B.01
22 8040-I REMOVE SIGNS
23 8040-999-X SALVAGE AND REINSTALL MAILBOX
CONTRACTOR SHALL REMOVE EXISTING MAILBOX AND POST. REINSTALL MAILBOX AS SHOWN ON D.02. INSTALL ON NEW POST IF EXISTING IS
DAMAGED DURING CONSTRUCTION.
CONTRACTOR SHALL AT THEIR OWN DISCRETION USE THE EXISTING MAILBOX IN THE TEMPORARY LOCATION.
24 9010-B HYDRAULIC SEEDING, SEEDING, FERTILIZING, AND MULCHING, TYPE 1 - PERMANENT LAWN SEED ALL AREAS DISTURBED BY CONSTRUCTION AS INDICATED ON PLANS. THE COST FOR WATERING UNTIL SEED ESTABLISHMENT IS ACCEPTED SHALL BE CONSIDERED INCIDENTAL TO THIS ITEM. ROCK PICKING, FINISH GRADING, SEED BED PREP AND RESEEDING ARE CONSIDERED INCIDENTAL TO THIS ITEM. SEED AND FERTILIZER SHALL BE APPLIED PRIOR TO MULCHING. THE CONTRACTOR IS RESPONSIBLE FOR MOWING AND MAINTAINING SEEDED AREAS UNTIL THE PROJECT IS ACCEPTED BY THE OWNER. SEEDING OF AREAS DISTURBED OUTSIDE OF THE CONSTRUCTION LIMITS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AT NO ADDITIONAL COST TO OWNER. THE SEEDING RATE SHALL BE AT LEAST 260 LBS/ACRE. APPLY A 6-24-24, NITROGEN, PHOSPHATE, POTASH, COMMERCIAL FERTILIZER OR EQUIVALENT AT THE RATE OF 300 LBS
PER ACRE. APPLY MULCHING PER MANUFACTERS RECOMMENDATIONS.
SEEDING AREAS ASSUMED FOR TWO APPLICATIONS OVER THE AREAS DISTURBED.
25 9020-A SOD
A. SOD ALL AREAS DISTURBED BY CONSTRUCTION UNLESS INDICATED ON PLANS. COST FOR WATERING SHALL BE CONSIDERED INCIDENTAL TO THIS ITEM. ROCK PICKING, FINISH GRADING, AND REWORK, INCLUDING REGRADING AND ADJUSTING GRADING, ARE CONSIDERED INCIDENTAL TO THIS ITEM. CONTRACTOR RESPONSIBLE FOR PROTECTING ALL SODDED AREAS THRU ESTABLISHMENT AND ACCEPTANCE. CONTRACTOR RESPONSIBLE FOR MOWING AND MAINTAINING SODDED AREAS UNTIL PROJECT IS ACCEPTED BY OWNER. SODDING OF AREAS OUTSIDE OF CONSTRUCTION LIMITS SHALL BE RESPONSIBILITY OF CONTRACTOR AT NO ADDITIONAL COST TO OWNER.
26 9040-F-1 WATTLE, COMPOST/MULCH SOCK
COMPOST/MULCH SOCK SHALL BE SELF WEIGHTED SO THAT WHEN PLACED ON PAVEMENT, STAKING IS NOT REQUIRED TO PREVENT
MOVEMENT CAUSED BY WATER.
27 9040-F-2 WATTLE, REMOVAL
CONTRACTOR SHALL REMOVE COMPOST/MULCH SOCK IN ITS ENTIRETY. MATERIAL FROM DAMAGED SOCKS SHALL BE REMOVED AND NOT
SPREAD ON SITE.
28 11010-A CONSTRUCTION SURVEY
CONTRACTOR TO PROVIDE CONSTRUCTION STAKING AS NECESSARY FOR CONSTRUCTION. MONUMENTS WITHIN CONSTRUCTION LIMITS TO BE
PROTECTED AND RESETTING OF DISTURBED MONUMENTS SHALL BE INCIDENTAL TO THIS ITEM.
CONTROL POINTS AND ALIGNMENT DATA ARE SHOWN ON G.01.
BOLTON & MENK TO PROVIDE THE FOLLOWING SUPPLEMENTAL DIGITAL DESIGN FILES:
- ALIGNMENT AND PROPOSED SURFACE DATA AS .XML
- CONTROL POINTS AS .CSV
- PROPOSED BASE LINE WORK AS .DWG
29 11020-A MOBILIZATION
CONTRACTOR SHALL PROVIDE TEMPORARY PLYWOOD/LAMINATED SIGNAGE TO MAINTAIN PACKAGE DELIVERY ON SITE. MAINTENANCE OF ACCESS TO THE LOWER PARKING LOT AT ALL TIMES THROUGH CONSTRUCTION SHALL BE INCIDENTAL TO THIS ITEM.
30 11030-A MAINTENANCE OF POSTAL SERVICE
CONTRACTOR SHALL MAINTAIN UNINTERUPTED POSTAL SERVICE BY USE OF TEMPORARY MAILBOX OR SETTING AND PROTECTING EXISTING
MAILBOX ON SITE.
SEE J.01 FOR LOCATION OF TEMPORARY SERVICE.
ESTIMATE REFERENCE INFORMATION (ALTERNATE A)
ITEM NO. ITEM
CODE DESCRIPTION
A1 7030-999-A REMOVAL OF STOOP FOUNDATION, INSTALL STOOP FOUNDATION AND SLAB
AFTER EVALUATION BY ENGINEER, IF FOUNDATION IS FOUND INAPPROPRIATE FOR REUSE, REMOVE STOOP FOUNDATIONS IN THEIR ENTIRETY
AND REPLACE STOOP FOOTING AND TOPING SLAB AS INDICATED ON SHEET S.01.
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
AA
DM
IN
_S T_
IA
\2
5X
0\
CA
D\
C3 D\
C0
1.
dw g 4/
/2
:1
7:
A M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF ADMINISTRATIVE SERVICES
DPS POST 13 - UPPER PARKING LOT REPLACEMENT
FAM
TJN
FAM
9511.000
0 ISSUED FOR BID 04/07/2026430 E GRAND AVENUE, SUITE 101
DES MOINES, IA 50309
Phone: (515) 259-9190
Email: DesMoines@bolton-menk.com www.bolton-menk.comR
TH
IS
S
HE
ET
S
ET
IS
IN
TE
N
DE
D
TO
B E
PL
O
TT
ED
IN
C
O
LO
R
C.02
ESTIMATE REFERENCE NOTES
>>DT >>
>>DT >>
>>DT >>
>>DT>>
DT
DT
DT
1+00
2+00
G/L G/L
G/L G/L
G/L G/L
G/L G/L
G/L G/L
G/L G/L
G/L G/L G/L G/L G/L
G/L
G/L G/L
G/L G/L
G/LG/LG/LG/LG/LG/LG/LG/LG/LG/LG/LG/LG/LG/L
G/ L
G/L
G/ L
G/ L
G/L
G/L
G/ L
G/LG/LG/LG/
L
G/ L
G/L
GGGGGGGGGGGGGGGGGGGGGGGGGGGGGG
DT
DT
F
F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F
P
E
W S
FFE = 696.85
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W R/W R/W R/W R/W R/W R/W R/W
0.
4%
2.
0%
1.
5%
1.
5%
PROPOSED GRADE AT
BUILDING CORNER:696.10
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
AA
DM
IN
_S T_
IA
\2
5X
0\
CA
D\
C3 D\
D0
1.
dw g 4/
/2
:1
7:
A M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF ADMINISTRATIVE SERVICES
DPS POST 13 - UPPER PARKING LOT REPLACEMENT
FAM
TJN
FAM
9511.000
0 ISSUED FOR BID 04/07/2026430 E GRAND AVENUE, SUITE 101
DES MOINES, IA 50309
Phone: (515) 259-9190
Email: DesMoines@bolton-menk.com www.bolton-menk.comR
TH
IS
S
HE
ET
S
ET
IS
IN
TE
N
DE
D
TO
B E
PL
O
TT
ED
IN
C
O
LO
R
R
FEETSCALE
0 5 10
HORZ. D.01
PARKING LOT LAYOUT
LEGEND
6" PCC PAVEMENT
CURB TRANSITION
4" PCC SIDEWALK
ADA RAMP (6" PCC)
TURNING SPACE (6" PCC)
DETECTABLE WARNING
22'
10' 8' 9' 9' 9' 9' 9' 10'
11'
18'
18'
R5' R5'
7'
6' 6'7'
5'
5' 7' TYP.
VAN ACCESSIBLE HC SIGN
DETAIL 4, B.01
VISITOR PARKING SIGN
DETAIL9, B.01
4 INCH YELLOW PAVEMENT MARKING
INSTALL DOWNSPOUT BOOT
ON EXISTING DOWN SPOUT.
DETAIL 8, B.01
4 INCH DRAINAGE PIPE,
SMOOTH INTERIOR NON-PERFORATED
2% MINIMUM TO DRAIN
SEE S.01 FOR STOOP AND STOREFRONT DETAILS.
PROTECT CONDUIT IN PLACE.
CONTRACTOR SHALL REMOVE AND REPLACE CONDUIT IF DAMAGED
DURING CONSTRUCTION AT NO ADDITIONAL COST TO OWNER.
STOREFRONT AND EXTERIOR WALL SHALL BE PROTECTED AT ALL TIMES
FROM DAMAGE, CONCRETE SPLATTER, ETC.
CONTRACTOR TO PROTECT
HOSEBID AND MOAT IN PLACE
PROTECT LIGHT POLE AND
UNDERGROUND UTILITIES
DURING CONSTRUCTION.
CONTRACTOR TO PROVIDE
ADAPTORS AND CONNECT
TO EXISTING DRAIN PIPE.
11'
5' CURB
TRANSITION
13'
5' CURB TRANSITION
13' 2'
2' CURB TRANSITION
13'
5' CURB TRANSITION
2'
5' 5'
11' 60.8'
PRIOR TO PIPE INSTALLATION, VERIFY
POTENTIAL UTILITY AND STRUCTURAL
CONFLICTS WITH TILE DEPTH AND
ALIGNMENT. COORDINATE WITH
ENGINEER ANY VARIANCE FROM DESIGN.
CLASS 'A' SIDEWALK, SEE
DETAIL 5, 6, 7 ON B.01
20'
DT
>>0+00 1+00 2+00 3+00
4+00
5+
6+
BP
: 0
+0 0.
PC: 3+29.67
PC: 4+73.33
PT: 4+24.85
PT: 5+43.42
R219'
R50'
ST
G/L G/L
G/L G/L
G/L
G/L G/L G/L G/L G/L G/L G/L
G/L
G/L
G/L
G/ L
G/L
G/L
G/L
G/L
G/L
G/L
G/L G/L
G/LG/LG/LG/LG/LG/LG/LG/L
G/L
G/ L
G/L
ST
F F F F F
F F
F F F F F F F
WM WM WM WM WM WM WM WM WM WM
W M
WM
CLVT
CLVT
TILE
F
W
G
G
G
G
G
G G
G G
G G
G
GGGGGGGGGGGGGGGGGGGGGGGGGGGG
DT
F F F F F F F F F F F F F F F F F F F F F F F F
P W
S
FFE = 696.85
R/W
R/W
R/W
R/W
R/W
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
R/W R/W
S. GRAND AVE
22'
22'
2.
0%
.0
2.
0%
.0
0.
4%
2.
0%
2.
0%
2.
0%
2.0% 2.0%
0.9% 1.2%
0.6% 1.0%
1.
5%
1.
5%
18" STM
INV = 684.80
-0.71% -1.00% -1.00% -1.06% 1.52%
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
AA
DM
IN
_S T_
IA
\2
5X
0\
CA
D\
C3 D\
D0
1.
dw g 4/
/2
:1
7:
A M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF ADMINISTRATIVE SERVICES
DPS POST 13 - UPPER PARKING LOT REPLACEMENT
FAM
TJN
FAM
9511.000
0 ISSUED FOR BID 04/07/2026430 E GRAND AVENUE, SUITE 101
DES MOINES, IA 50309
Phone: (515) 259-9190
Email: DesMoines@bolton-menk.com www.bolton-menk.comR
TH
IS
S
HE
ET
S
ET
IS
IN
TE
N
DE
D
TO
B E
PL
O
TT
ED
IN
C
O
LO
R
R
FEETSCALE
0 20 40
HORZ. D.02
PLAN & PROFILE - ENTRANCE DRIVE
TIE NEW PCC PAVEMENT TO EXISTING WITH
#4 REBAR 36 INCH ON CENTER
OR
#3 REBAR 18 INCH ON CENTER
CENTERLINE JOINT SHALL BE TIED JOINT (TYP.)
#4 REBAR 36 INCH ON CENTER
OR
#3 REBAR 18 INCH ON CENTER
CONTRACTOR TO MAKE FINAL SAW CUT IMMEDIATELY
PRIOR TO PAVING. ADDITIONAL SAW CUTS, PAVEMENT
REMOVALS, AND PCC PAVEMENT REQUIRED DUE TO
DAMAGED HMA INTERFACE SHALL BE INCIDENTAL TO
CONSTRUCTION.
REINSTALL SALVAGED MAILBOX
REMOVE 1309 SY DRIVEWAY PAVEMENT
SEE GEOTECH REPORT FOR DETAILS.
REMOVE 90 SY SIDEWALK PAVEMENT
ST
F F F F F
F F
F F F F F F F
WM WM WM WM WM WM WM WM WM WM
W M
WM
CLVT
CLVT
TILE
F
W
G
G
G
G
G
G G
G G
G G
G
GGGGGGGGGGGGGGGGGGGGGGGGGGGG
DT
F F F F F F F F F F F F F F F F F F F F F F F F
P W
S
FFE = 696.85
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
FULL DEPTH SAW CUT AT REMOVAL LIMITS.
PROTECT PAVEMENT TO REMAIN.
PROTECT EXISTING CULVERT TO REMAIN.
SEE PROFILE ON D.02 FOR DETAILS ON CROSSING DEPTH
REMOVE AND SALVAGE MAILBOX FOR REINSTALL.
SEE J.01 FOR TEMPORARY MAILBOX LOCATION
SEE D.02 FOR REINSTALLATION LOCATION.
REMOVE SIGN
BASE BID:
DEMO EXISTING STOOP SLAB. COORDINATE
WITH ENGINEER IMMEDIATELY FOLLOWING
REMOVAL OF TOP SLAB.
SEE ESTIMATE REFERENCE NOTES FOR
CONTINUATION OF BASE BID OR ALT A
S. GRAND AVE
CONTRACTOR TO PROTECT EXISTING
STOREFRONT AND BUILDING EXTERIOR
FROM DAMAGE AT ALL TIMES.
PROTECTION SHALL BE SELF SUPPORTED
AND NOT AFFIXED TO THE BUILDING.
FULL DEPTH SAW CUT AT REMOVAL LIMITS. DOUBLE SAW
CUT AS NECESSARY TO PROTECT PAVEMENT TO REMAIN
AND MAINTAIN CLEAN JOINT TO MATCH TO.
NO ADDITIONAL PAYMENT WILL BE MADE FOR ADDITIONAL
SAW CUTS, REMOVALS OR PCC PAVEMENT NECESSARY TO
REMEDY DAMAGED EDGE DURING CONSTRUCTION
PRIOR TO PAVEMENT REMOVALS, CUT PIPE TO
PREVENT DAMAGE OF PIPE TO REMAIN.
REMOVE DRAIN INTAKE, SEE IMAGE ON BOTTOM
RIGHT OF THIS PAGE
LIMIT PIPE REMOVALS ONLY AS NECESSARY TO
FACILITATE CONNECTION AND INSTALLATION AS
SHOWN ON D.01
REMOVE LANDSCAPE BLOCK, PLANT
MATERIAL AND ROCK MULCH
REMOVE LANDSCAPE EDGE AND
PLANT MATERIAL WITHIN. PROTECT
LIGHT POLE AND UTILITIES.
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
AA
DM
IN
_S T_
IA
\2
5X
0\
CA
D\
C3 D\
F0
1.
dw g 4/
/2
:1
7:
A M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF ADMINISTRATIVE SERVICES
DPS POST 13 - UPPER PARKING LOT REPLACEMENT
FAM
TJN
FAM
9511.000
0 ISSUED FOR BID 04/07/2026430 E GRAND AVENUE, SUITE 101
DES MOINES, IA 50309
Phone: (515) 259-9190
Email: DesMoines@bolton-menk.com www.bolton-menk.comR
TH
IS
S
HE
ET
S
ET
IS
IN
TE
N
DE
D
TO
B E
PL
O
TT
ED
IN
C
O
LO
R
R
FEETSCALE
0 10 20
HORZ. F.01
EXISTING CONDITIONS
VIEW OF DRAIN INTAKE FROM WEST, LOOKING EAST.
UNDERGROUND UTILITIES:
UTILITIES SHOW ON THESE PLANS ARE DRAWN IN BASED ON FIELD LOCATES, UTILITY MAPS, AND HISTORICAL DATA. NOT ALL UTILITIES WITHIN THIS SITE MAY BE SHOWN, AND NOT ALL UTILITIES SHOWN MAY BE ACCURATE. CONTRACTOR SHALL HAVE ALL PUBLIC AND PRIVATE UTILITIES LOCATED AND POTHOLED PRIOR TO
CONSTRUCTION AS NECESSARY TO PROTECT UTILITIES IN PLACE.
F F F F F
F F
F F F F F F F l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l
CLVT
CLVT
TILE
F
W
G
G
G
G
G
G G
G G
G G
G
GGGGGGGGGGGGGGGGGGGGGGGGGGGG
F F F F F F F F F F F F F F F F F F F F F F F F
P l l
W S
FFE = 696.85
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
0+00 1+00 2+00 3+00
4+00
5+
6+
6+42.88
BP
: 0
+0 0.
PC
: 3
+2 9.
PT: 4+24.85
PC: 4+73.33
PT: 5+43.42
EP: 6+42.88
POINT NORTHING-EASTING DATA
POINT NUMBER
RAW DESCRIPTION
VFCP CP
VFCP 5/8" ALUM DOT ROW
VFCP CP
ELEVATION
696.000
683.740
689.040
NORTH
352785.58
353225.94
353066.42
EAST
2181987.27
2182014.39
2182081.26
L1
L2
L3
C1
C2
ALIGNMENT - CENTERLINE
NUMBER
L1
C1
L2
C2
L3
START STATION
0+00
3+29.67
4+24.85
4+73.33
5+43.42
END STATION
3+29.67
4+24.85
4+73.33
5+43.42
6+42.88
LENGTH
329.67
95.18
48.48
70.09
99.45
DELTA
23°42'40"
65°50'08"
RADIUS
230.00
61.00
CHORD
94.50
66.30
START N
352701.27
353030.88
353122.97
353166.97
353202.36
START E
2182048.18
2182041.77
2182020.56
2182000.20
2181944.14
END N
353030.88
353122.97
353166.97
353202.36
353201.21
END E
2182041.77
2182020.56
2182000.20
2181944.14
2181844.69
LINE / CHORD DIRECTION
N1° 06' 51"W
N12° 58' 11"W
N24° 49' 30"W
N57° 44' 35"W
S89° 20' 21"W
SOIL BORING #3
APPROX. 5 INCH ASPHALT
EXISTING PAVEMENT
SOIL BORING #2
APPROX. 6.5 INCH ASPHALT
EXISTING PAVEMENT
SOIL BORING #1
APPROX. 6 INCH ASPHALT
EXISTING PAVEMENT
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
AA
DM
IN
_S T_
IA
\2
5X
0\
CA
D\
C3 D\
G0
1.
dw g 4/
/2
:1
7:
A M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF ADMINISTRATIVE SERVICES
DPS POST 13 - UPPER PARKING LOT REPLACEMENT
FAM
TJN
FAM
9511.000
0 ISSUED FOR BID 04/07/2026430 E GRAND AVENUE, SUITE 101
DES MOINES, IA 50309
Phone: (515) 259-9190
Email: DesMoines@bolton-menk.com www.bolton-menk.comR
TH
IS
S
HE
ET
S
ET
IS
IN
TE
N
DE
D
TO
B E
PL
O
TT
ED
IN
C
O
LO
R
G.01
REFERENCES AND BENCHMARKS
R
FEETSCALE
0 20 40
HORZ.
SOIL BORING NOTES:
SEE GEOTECHNICAL REPORT FOR DETAILS.
F F F F F
F F
F F F F F F F l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l
CLVT
CLVT
TILE
F
W
G
G
G
G
G
G G
G G
G G
G
GGGGGGGGGGGGGGGGGGGGGGGGGGGG
F F F F F F F F F F F F F F F F F F F F F F F F
P l l
W S
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
PHASE 2A
PHASE 2B
S. GRAND AVE
CONTRACTOR TO PROVIDE TEMPORARY
SIGNAGE TO MAINTAIN DELIVERIES
"USE LOWER PARKING LOT AND REAR
DOOR FOR DELIVERIES..."
COORDINATE WITH OWNER FOR EXACT
VERBIAGE.
MAINTAIN ACCESS WITH GRAVEL.
REDUCE ACCESS ONLY WHEN
PAVING HALF ENTRANCE WIDTH
CONTRACTOR TO PROVIDE TEMPORARY MAIL BOX AT
THIS LOCATION. INSTALLATION SHALL COMPLY WITH
UNITED STATES POSTAL SERVICE REQUIREMENTS TO
ENSURE UN-INTERRUPTED MAIL DELIVERY.
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
AA
DM
IN
_S T_
IA
\2
5X
0\
CA
D\
C3 D\
J0
1.
dw g 4/
/2
:1
7:
A M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF ADMINISTRATIVE SERVICES
DPS POST 13 - UPPER PARKING LOT REPLACEMENT
FAM
TJN
FAM
9511.000
0 ISSUED FOR BID 04/07/2026430 E GRAND AVENUE, SUITE 101
DES MOINES, IA 50309
Phone: (515) 259-9190
Email: DesMoines@bolton-menk.com www.bolton-menk.comR
TH
IS
S
HE
ET
S
ET
IS
IN
TE
N
DE
D
TO
B E
PL
O
TT
ED
IN
C
O
LO
R
J.01
STAGTING
R
FEETSCALE
0 20 40
HORZ.
PHASING NOTES:
PHASE 1:
- REMOVE EXISTING PAVEMENT. LIMIT REMOVALS WHERE POSSIBLE TO
MAINTAIN ACCESS TO LOWER PARKING LOT AND NOT EXPOSE SUBGRADE FOR
EXTENDED PERIOD OF TIME.
- LOWER PARKING LOT SHALL REMAIN ACCESSIBLE TO VEHICULAR TRAFFIC
THROUGH THE DURATION OF CONSTRUCTION.
- CONTRACTOR SHALL PROTECT EXISTING SUBGRADE FROM EXCESS MOISTURE
WHERE PAVEMENT IS REMOVED.
PHASE 2:
- CONTRACTOR SHALL PROVIDE AGGREGATE RAMP BETWEEN PAVEMENT AND
SUBGRADE TO MAINTAIN ACCESS TO SITE AND LOWER PARKING LOT
- CONTRACTOR SHALL PERFORM WORK FOR PHASE 2A AND 2B IN THE ORDER
THAT BEST SUITS CONTRACTIBILITY AND MAINTAINING ACCESS
GGGGGGGGGGGGGGGGGGGGGGGGGGGGGG
DT
DT
F
F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F
P
E
W S
FFE = 696.85
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W R/W R/W R/W R/W R/W R/W R/W
>>DT >>
>>DT >>
>>DT >>
>>DT >>
>>DT>>
DT
DT
DT
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W R/W R/W R/W R/W R/W R/W R/W
6'7' 6'
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
692.15
693.14
693.31
694.05
696.61
696.61
696.81 696.81
11'
693.99 693.81
R5' R5'
10.0'
10.0'
1.
5%
1.
5%
693.43 TC
692.93 FG
693.72 TC
693.22 FG
3.
T
C
3.
F G
3.
T
C
3.
F G
693.17 TC
693.17 FG
693.75 TC
693.25 FG
693.94 TC
693.44 FG
3.
T
C
3.
F G
693.70 TC
693.20 FG
693.02 TC
692.53 FG
692.44 TC
692.45 FG
3.
T
C
3.
F G
3.
T
C
3.
F G
1.0%
49.0'
1.
5% 7.
0'
1.
5%7.
0'
1.
5% 6.
5'
1.
5%6.
5'
1.
5% 7.
0'
2.
0%4.
0'
2.
0%6.
0'
0.0%
11.0'
2.
0% 5.
0'
2.
0% 5.
0'
0.0%
11.0'
1.
5%7.
0'
1.
5%
.0
1.
5% 9.
0'
1.
5% 9.
0'
1.
5% 9.
0'
0.7%
11.0'
1.0%
10.0'
1.0%
9.0'
1.0%
9.0'
1.0%
9.0'
1.0%
9.0'
1.0%
9.0'
1.0%
9.0'
1.0%
10.0'
1.0%
9.0'
1.0%
9.0'
1.0%
9.0'
1.0%
9.0'
1.0%
1.
5%
1.0%8.0%1.1%
0.7%
693.09 TC
692.90 FG
7.3%
1.
5% 9.
0'
1.0%
9.0' 1.0%
9.0' 1.0%
693.21 TC
692.72 FG
7' TYP.
5' TYP.
4.5%
693.04
692.91
692.77
692.64
692.95
692.82
692.68
692.55 692.46
692.59
692.73
692.86 692.77
692.64
692.50
692.37 692.28
692.41
692.55
692.68
692.31
692.18
692.73
692.86
693.00
693.13
693.22
693.09
692.95
692.82
693.06
692.91
692.99
693.58 TC
693.08 FG
693.49 TC
692.99 FG
693.40 TC
692.90 FG
693.31 TC
692.81 FG
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
AA
DM
IN
_S T_
IA
\2
5X
0\
CA
D\
C3 D\
L0
1.
dw g 4/
/2
:1
7:
A M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF ADMINISTRATIVE SERVICES
DPS POST 13 - UPPER PARKING LOT REPLACEMENT
FAM
TJN
FAM
9511.000
0 ISSUED FOR BID 04/07/2026430 E GRAND AVENUE, SUITE 101
DES MOINES, IA 50309
Phone: (515) 259-9190
Email: DesMoines@bolton-menk.com www.bolton-menk.comR
TH
IS
S
HE
ET
S
ET
IS
IN
TE
N
DE
D
TO
B E
PL
O
TT
ED
IN
C
O
LO
R
R
FEETSCALE
0 5 10
HORZ. L.01
JOINTING LAYOUT
LEGEND
6" PCC PAVEMENT
CURB TRANSITION
4" PCC SIDEWALK
ADA RAMP (6" PCC)
TURNING SPACE (6" PCC)
DETECTABLE WARNING
B.01
B.01
B.01
1 INCH EXPANSION JOINT
SAWN JOINT (TYP.)
TIED JOINT (TYP.)
#4 REBAR 36 INCH ON CENTER
OR
# 3 REBAR 18 INCH ON CENTER
1/2 INCH EXPANSION JOINT
AT CLASS 'A' SIDEWALK
F F F F F
F F
F F F F F F F l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l
CLVT
CLVT
TILE
F
W
G
G
G
G
G
G G
G G
G G
G
GGGGGGGGGGGGGGGGGGGGGGGGGGGG
F F F F F F F F F F F F F F F F F F F F F F F F
P W
S
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
SOD
INSTALL BMP IN FRONT OF PIPE APRON
692 691
691692
4'
2'
2'
2'
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
AA
DM
IN
_S T_
IA
\2
5X
0\
CA
D\
C3 D\
R0
1.
dw g 4/
/2
:1
8:
A M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF ADMINISTRATIVE SERVICES
DPS POST 13 - UPPER PARKING LOT REPLACEMENT
FAM
TJN
FAM
9511.000
0 ISSUED FOR BID 04/07/2026430 E GRAND AVENUE, SUITE 101
DES MOINES, IA 50309
Phone: (515) 259-9190
Email: DesMoines@bolton-menk.com www.bolton-menk.comR
TH
IS
S
HE
ET
S
ET
IS
IN
TE
N
DE
D
TO
B E
PL
O
TT
ED
IN
C
O
LO
R
R.01
EROSION CONTROL PLAN - POST CONSTRUCTION
R
FEETSCALE
0 20 40
HORZ.
NOTE:
1. TEMPORARY EROSIONS CONTROL BEST MANAGEMENT PRACTICES
(BMPs) AS SHOWN ON THIS PLAN SHEET THAT WILL NOT BE
INCORPORATED INTO THE FINAL PRODUCT ARE
RECOMMENDATIONS. THE CONTRACTOR IS RESPONSIBLE FOR
DESIGNING, INSTALLING, AND MODIFYING BMPs AS NECESSARY
TO PREVENT ILLICIT DISCHARGE FROM THE PROJECT SITE.
2. SOD SHALL BE INSTALL ON DOWN HILL SIDE EDGE OF PAVEMENT
AS SHOWN.
3. INSTALL COMPOST/MULCH SOCK OR OTHER SELF-WEIGHTING
TYPE BMP ON PAVEMENT UP-STREAM FROM SOD UNTIL SOD IS
FULLY ROOTED. REMOVE BMP IN ITS ENTIRETY FROM SITE.
COMPOST/MULCH FROM BMP SHALL NOT BE SPREAD ON SITE.
4. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO SITE AS SHOW
BY LIMITS OF SOD AND SEEDING.
5. CONTRACTOR IS RESPONSIBLE FOR THEIR CONSTRUCTION
OPERATIONS ON SITE AND SHALL RE-ESTABLISH GRADE AND
RE-SEED ANY ADDITIONAL DISTURBANCE AT NO ADDITIONAL
COST TO THE OWNER.
MAJOR CONTOUR - EXISTING
MINOR CONTOUR - EXISTING
MAJOR CONTOUR - PROPOSED
MINOR CONTOUR - PROPOSED
COMPOST/MULCH SOCK
TYPE 1 LAWN - HYDROSEED
EROSION CONTROL LEGEND
SOD
O M
S.01
STOOP REPLACEMENT AND STOREFRONT MODIFICATIONS
DESIGN CRITERIA:
1. CODES AND STANDARDS:
2024 IBC/ASCE 7-22
OCCUPANCY/RISK CATEGORY II
2. DESIGN DEAD LOADS:
CONCRETE: 150 PCF
3. DESIGN LIVE LOADS:
EXIT WAYS: 100 PSF
4. DESIGN SNOW LOADS:
GROUND SNOW LOAD: Pg = 38 PSF
6. SEISMIC LOAD:
SEISMIC IMPORTANCE FACTOR: Ie = 1.00
MAPPED SPECTRAL ACCELERATION, SHORT: SS = 0.15
MAPPED SPECTRAL ACCELERATION, 1-SEC: S1 = 0.079
SITE CLASS: D
DESIGN SPECTRAL ACCELERATION, SHORT: SDS = 0.14
DESIGN SPECTRAL ACCELERATION, 1-SEC: SD1 = 0.11
SEISMIC DESIGN CATEGORY: B
GENERAL NOTES
DESIGN:
1. GEOTECHNICAL EXPLORATION HAS NOT BEEN PERFORMED FOR THIS PROJECT. THE
FOUNDATION HAS BEEN DESIGNED IN ACCORDANCE WITH THE MAXIMUM ASSUMED VALUES
PERMITTED BY THE 2024 INTERNATIONAL BUILDING CODE.
2 BACKFILLING:
A. DO NOT BACKFILL PIT WALLS UNTIL ADEQUATE TEMPORARY BRACING IS INSTALLED.
B. BACKFILL UNDER FOUNDATION WITH CONCRETE OR AS APPROVED BY SOILS ENGINEER.
SPREAD FOOTINGS:
1. FOOTINGS SHALL BEAR ON SOIL CAPABLE OF SUSTAINING A NET BEARING PRESSURE UNDER
FULL SERVICE LIVE AND DEAD LOAD AS FOLLOWS:
1,500 PSF FOR FOUNDATIONS BEARING ON SUITABLE NATIVE SOIL OR ENGINEERED FILL
2. ALL BEARING MATERIAL SHALL BE INSPECTED BY A QUALIFIED TECHNICIAN PRIOR TO
CONCRETE PLACEMENT. A QUALIFIED TECHNICIAN SHALL BE THE SOLE JUDGE AS TO THE
SUITABILITY OF THE BEARING MATERIAL. FOOTING ELEVATIONS SHALL BE ADJUSTED AS
REQUIRED. OVEREXCAVATION MAY BE REQUIRED.
3. BOTTOM OF EXTERIOR FOOTINGS SHALL BEAR A MINIMUM OF 3'-6" BELOW FINAL GRADE.
FOUNDATIONS
1. CONCRETE SHALL BE CONSTRUCTED IN ACCORDANCE WITH IBC CHAPTER 19 AND ACI 318.
2. PROVIDE CONCRETE MIX DESIGNS COMPLYING WITH ACI PRC-211.1 RECOMMENDATIONS.
COMPRESSIVE STRENGTHS, f'c, INDICATED ARE AT 28 DAYS. CONCRETE MATERIALS AND
MIXTURES FOR BUILDING ELEMENTS SHALL BE AS FOLLOWS:
A. CONCRETE MATERIALS:
i. CEMENT: ASTM C150, TYPE I OR ASTM C595, TYPE IL
ii. AGGREGATES: ASTM C33
iii. FLY ASH: ASTM C618, CLASS C OR F; LIMIT TO 25% OF TOTAL CEMENTITOUS MATERIAL
iv. ADMIXUTRES: AS RECOMMENDED IN ACI PRC-211.1 AND AT RATES RECOMMENDED
BY MANUFACTURER:
a. AIR ENTRAINMENT: ASTM C260
b. WATER REDUCING, RETARDING AND/OR ACCELERATING: ASTM C494, TYPE A-G
B. DESIGN MIXTURES:
i. FOUNDATION WALLS AND STOOP SLABS:
f'c = 4,500 PSI w/c = 0.45 MAX
AIR CONTENT = 6% +/- 1.5%
SLUMP = 4"-8" FOR CONCRETE w/ VERIFIED SLUMP OF 2"-4" BEFORE ADDING HIGH-
RANGE WATER-REDUCING OR PLASTICIZING ADMIXTURE
MAX. AGGREGATE SIZE = 1"
3. REINFORCING SHALL CONFORM TO ASTM A615, GR. 60, INCLUDING TIES AND STIRRUPS.
4. ALL REINFORCING SHALL BE DETAILED, FABRICATED AND PLACED, IN ACCORDANCE WITH ACI
DETAILING MANUAL. NO FIELD BENDING OF REINFORCEMENT SHALL BE PERMITTED EXCEPT
WHERE SPECIFICALLY NOTED IN THE DRAWINGS.
5. ALL REINFORCING SHALL BE SUPPORTED IN FORMS, SPACED WITH NECESSARY ACCESSORIES
AND SHALL BE SECURELY WIRED TOGETHER, IN ACCORDANCE WITH CRSI"REINFORCING BAR
DETAILING". ALL DOWELS, ANCHOR RODS, EMBEDS, SLEEVES AND OTHER EMBEDDED ITEMS SHALL
BE SECURELY TIED AND SUPPORTED PRIOR TO POURING CONCRETE.
NO WET-SETTING SHALL BE PERMITTED.
6. MINIMUM CONCRETE COVER, UNLESS NOTED OTHERWISE:
A. UNFORMED SURFACE IN CONTACT WITH THE GROUND: 3 IN.
B. FORMED SURFACES EXPOSED TO EARTH OR WEATHER: 1 1/2 IN. FOR #5 BAR OR
SMALLER 2 IN FOR #6 BAR OR LARGER
C. FORMED SURFACES NOT EXPOSED TO EARTH OR WEATHER:
1. WALLS, SLABS: 3/4 IN.
2. BEAMS, GIRDERS AND COLUMNS (TO TIES OR STIRRUPS): 1 1/2 IN.
7. ALL CONSTRUCTION JOINTS SHOWN ON DRAWINGS SHALL BE INCORPORATED INTO THE
STRUCTURE, UNLESS THEIR ELIMINATION IS APPROVED BY THE ENGINEER. ADDITIONAL
CONSTRUCTION JOINTS, REQUIRED TO FACILITATE CONSTRUCTION, SHALL BE LOCATED AT
POINTS OF MINIMUM SHEAR AND SHALL BE DETAILED ON SHOP DRAWINGS. REINFORCEMENT SHALL
PASS CONTINUOUSLY THROUGH THE JOINT.
8. ALL ABUTTING CONCRETE MEMBERS SHALL BE DOWELED TOGETHER, UNLESS POURED
MONOLITHICALLY. DOWELS SHALL BE EQUAL IN SIZE AND SPACING TO THE REINFORCING IN THE
ADJACENT MEMBER. WHERE CONCRETE IS PLACED AGAINST HARDENED CONCRETE, THE SURFACE
SHALL BE ROUGHENED TO MINIMUM 1/4" AMPLITUDE.
9. STOOP SLABS SHALL HAVE A BROOMED FINISH. WHERE FINISH IS NOT SPECIFIED, CONFORM TO
REQUIREMENTS OF ACI 301.
10. CIVIL DRAWINGS SHALL BE REFERRED TO FOR DRAINS,SLEEVES, OUTLET BOXES, CONDUIT, ETC.
11. LAP SPLICES SHALL BE A MINIMUM OF 24".
12. PROVIDE STANDARD HOOKS ON BARS TERMINATING AT A CONCRETE FACE UNLESS NOTED (E.G.:
SLAB EDGES, EXPANSION JOINTS, AND AT: TOP, BOTTOM AND ENDS OF WALLS, ETC...).
13. FOLLOW RECOMMENDATIONS OF ACI PRC-305 AND ACI PRC-306 WHEN CONCRETING DURING
HOT OR COLD WEATHER, RESPECTIVELY.
14. FORMWORK DESIGN AND CONSTRUCTION SHALL COMPLY WITH GUIDELINES OF ACI PRC-347
TO PROVIDE FORMWORK THAT WILL PRODUCE CONCRETE COMPLYING WITH TOLERANCES
OF ACI SPEC-117.
15. CONCRETE SHALL BE CURED AND PROTECTED IN ACCORDANCE WITH ACI PRC-308.
16. WHERE INDICATED IN DRAWINGS, PROVIDE SLAB ISOLATION JOINT FILLER COMPLYING WITH ASTM D1751, CELLULOSE FIBER. JOINT FILLER SHALL BE 1/2" THICK, HEIGHT EQUAL TO SLAB
THICKNESS, WITH REMOVABLE TOP SECTION FORMING 1/2" DEEP SEALANT POCKET AFTER
REMOVAL.
17. JOINT SEALANT: SONOLASTIC MASTERSEAL NP-1 (OR APPROVED EQUAL), ONE COMPONENT
MOISTURE CURING POLYURETHANE. ASTM C920, TYPE S, GRADE NS, CLASS 35, USES A AND T.
BACKER ROD IS REQUIRED BELOW JOINT SEALANT PER MANUFACTURERS WRITTEN INSTRUCTIONS.
CONCRETEMISCELLANEOUS
1. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS, SUCH AS DIMENSIONS, ELEVATIONS, CONFIGURATION, AND DETAILS OF EXISTING STRUCTURES AND CONDITIONS
WHERE THEY AFFECT NEW CONSTRUCTION. NOTIFY ENGINEER IMMEDIATELY IF ANY
DEVIATIONS FROM ANTICIPATED CONDITIONS ARE DISCOVERED. CONFIRM FIELD VERIFIED
CONDITIONS & DIMENSIONS WITH ENGINEER PRIOR TO START OF CONSTRUCTION.
2. COORDINATION W/ COMPLETE SET OF CONTRACT DOCUMENTS: THE CONTRACT DOCUMENTS
ARE ONE COMPLETE, COMPREHENSIVE AND INCLUSIVE DOCUMENT CONSISTING OF THE
AGGREGATE COLLECTION OF DRAWINGS AND SPECIFICATIONS FOR ALL OF THE DISCIPLINES'
DIVISIONS (E.G. SITE, CIVIL, ETC.). NO SINGLE DISCIPLINE DIVISION IS AUTONOMOUS NOR DOES
IT STAND-ALONE FROM ANY OR ALL OTHER DISCIPLINE DIVISIONS.
3. VERIFY ALL DIMENSIONS, ELEVATIONS, DEPRESSIONS, INSERTS, EMBEDDED ITEMS. EQUIPMENT
PADS AND SUPPORTS, OPENINGS, DETAILS, AND CONDITIONS BY CROSS-REFERENCING TO
CIVIL SECTIONS.
4. SEE CIVIL DRAWINGS FOR DIMENSIONS NOT SHOWN ON STRUCTURAL DRAWINGS.
5. NO OPENING SHALL BE MADE IN ANY STRUCTURAL MEMBER WITHOUT THE WRITTEN APPROVAL
OF THE ENGINEER.
6. NO CHANGE IN SIZE OR DIMENSION OF STRUCTURAL MEMBERS SHALL BE MADE WITHOUT THE
WRITTEN APPROVAL OF THE ENGINEER.
7. OPENINGS 1'-4" AND LESS ON A SIDE ARE GENERALLY NOT SHOWN ON THE STRUCTURAL
DRAWINGS. REFER TO CIVIL DRAWINGS FOR COORDINATION OF SUCH OPENINGS.
8. THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. THE CONTRACTOR
IS RESPONSIBLE FOR FURNISHING ALL TEMPORARY BRACING AND/OR SUPPORT THAT MAY BE
REQUIRED AS THE RESULT OF THE CONTRACTOR'S CONSTRUCTION METHODS AND/OR
SEQUENCES.
9. DO NOT SCALE THESE DRAWINGS, USE DIMENSIONS.
10. THE CONTRACTOR SHALL INFORM THE ENGINEER IN WRITING OF ANY DEVIATION FROM THE
CONTRACT DOCUMENTS. THE CONTRACTOR SHALL NOT BE RELIEVED OF THE RESPONSIBILITY
FOR SUCH DEVIATION BY THE ENGINEER'S APPROVAL OF SHOP DRAWINGS, PRODUCT DATA,
ETC., UNLESS HE HAS SPECIFICALLY INFORMED THE ENGINEER OF SUCH DEVIATION AT THE
TIME OF SUBMISSION, AND THE ENGINEER HAS GIVEN WRITTEN APPROVAL TO THE SPECIFIC
DEVIATION.
11. ALL THINGS WHICH, IN THE OPINION OF THE CONTRACTOR, APPEAR TO BE DEFICIENCIES, OMISSIONS, CONTRADICTIONS, OR AMBIGUITIES, IN THE PLANS AND SPECIFICATIONS SHALL BE
BROUGHT TO THE ATTENTION OF THE ENGINEER. PLANS AND/OR SPECIFICATIONS WILL BE
CORRECTED, OR WRITTEN INTERPRETATION OF THE ALLEGED DEFICIENCY, OMISSION,
CONTRADICTION OR AMBIGUITY WILL BE MADE BY THE ENGINEER BEFORE THE EFFECTED
WORK PROCEEDS.
12. ASTM AND OTHER CODE STANDARDS REFERENCED IN THESE DRAWINGS SHALL BE THE
VERSION REFERENCED BY THE APPLICABLE VERSION OF IBC.
1. THE FOLLOWING ITEMS SHALL BE SUBMITTED FOR REVIEW:
• CONCRETE MIX DESIGNS, INCLUDING PRODUCT DATA
• CONCRETE REINFORCEMENT
• JOINT SEALANT
2. CONTRACTOR SHALL REVIEW EACH SUBMITTAL FOR CONFORMANCE WITH CONTRACT
DOCUMENTS. SUBMITTALS NOT REVIEWED BY THE CONTRACTOR AND STAMPED SUCH WILL BE
REJECTED AND SENT BACK TO THE CONTRACTOR FOR REVIEW. IT IS THE CONTRACTOR'S
This is the start of the file's text. The full file is on GovTribe.