RFB949600-01 - Drawings.pdf
PDF 2 MB Posted
- Solicitation number
- RFB949600-01
- Issued by
- Carroll County, Iowa
About this file
This is an architectural drawings document prepared for the Iowa Department of Administrative Services (DAS) on behalf of the Iowa Department of Corrections (DOC) for the North Central Correctional Facility Education Building Window Replacement project located in Rockwell City, Iowa. The project involves the removal and replacement of windows throughout the education building at the correctional facility. The drawings include site plans, floor plans for multiple levels, exterior elevations, and detailed window specifications and installation diagrams. The project encompasses numerous window types designated as Window A through Window L, with variations including standard insulated glazing (IG), insulated panels (IP), and fire-rated (FR) options across three floors of the building. The bid due date is June 1, 2026, at 2:00 PM CDT, with bid opening scheduled for May 7, 2026, at 9:30 AM CDT. The drawings are dated April 27, 2026, and were prepared by CMBA Architects of Spencer, Iowa, with architect Adam Van Gorp, AIA, responsible for the design. The construction is classified as a Level 1 alteration under the 2024 International Existing Building Code, with the building using Type VB construction, two stories, and approximately 35 feet in height.
The project specifications require contractors to coordinate extensively with North Central Correctional Facility staff regarding site access, gate passing, and work phasing room by room. All contractor personnel must complete background checks and PREA training before accessing the facility. Daily tool inventory requirements apply, with all construction equipment to be removed from the site daily except for a secured job box on the roof. Contractors must maintain weather-tight conditions throughout construction, handle daily waste removal, and protect existing utilities, grass areas, and finishes. Material specifications include moisture-treated exterior blocking, composite trim with solid surface sills, prefinished aluminum flashing, insulation, weather barriers, and backer rod and sealant at all window locations. Window grids are noted as an alternate bid item. Bid security of 5 percent of the total bid amount is required, and contractors must submit Subcontractor Targeted Small Business Enterprise Pre-Bid Contract Information as part of the bidding process to promote small business participation in accordance with Iowa Code Chapter 73. The specific project budget has not been disclosed in the available documentation.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ABBREVIATIONS
AB AIR BARRIER
AFF ABOVE FINISH FLOOR
ACT ACOUSTICAL CEILING TILE
ALT. ALTERNATE
ALUM. ALUMINUM
APPROX. APPROXIMATE
ARCH. ARCHITECT (URAL)
AVB AIR AND VAPOR BARRIER
BD. BOARD
BES BUILDING ENVELOPE SEALANT
BG BUMPER GUARD
BGW BELOW GRADE WATERPROOFING
MEMBRANE
B.O. BOTTOM OF
BRG. BEARING
CC CUBICLE CURTAIN
CFCI CONTRACTOR FURNISHED-CONTRACTOR
INSTALLED
CG CORNER GUARD
CJ CONTROL JOINT
CL CENTERLINE
CLG. CEILING
CMU CONCRETE MASONRY UNIT
COL. COLUMN
CONC. CONCRETE
CONST. CONSTRUCTION
CONT. CONTINUOUS
CORR. CORRIDOR
CPT. CARPET
CR CHAIR RAIL
CT CERAMIC TILE
DIA. DIAMETER
DIM. DIMENSION
DN. DOWN
DS DOWNSPOUT
DTL. DETAIL
DVB DECK VAPOR BARRIER
DWG. DRAWING
EA. EACH
EG END GUARD
EJ EXPANSION JOINT
ELEC. ELECTRICAL
ELEV. ELEVATOR
EPT EPOXY PAINT
EQ. EQUAL
EQUIP. EQUIPMENT
EW EACH WAY
EXIST. EXISTING
EXP. EXPOSED
EXT. EXTERIOR
FAF FLUID APPLIED FLOORING
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FIN. FINISH (ED)
FLR. FLOOR
FND. FOUNDATION
FRP FIBERGLASS REINFORCED PANEL
FRT FIRE RETARDANT TREATED
FTG. FOOTING
FV FIELD VERIFY
GA. GAUGE
GALV. GALVANIZED
GC GENERAL CONTRACTOR
GFRG GLASS FIBER REINFORCED GYPSUM
GL GLASS
GYP. GYPSUM
GWB GYPSUM WALL BOARD
HM HOLLOW METAL
HORIZ. HORIZONTAL
HR HANDRAIL
HVAC HEATING, VENTILATING, AIR CONDITIONING
INT. INTERIOR
JST. JOIST
JT. JOINT
KIT. KITCHEN
LAV. LAVATORY
MAX. MAXIMUM
MB MARKER BOARD
MDF MEDIUM DENSITY FIBERBOARD
MECH. MECHANICAL
MFR. MANUFACTURER
MIN. MINIMUM
MISC. MISCELLANEOUS
MTL. METAL
NIC NOT IN CONTRACT
NOM. NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OFOI OWNER FURNISHED-OWNER INSTALLED
OFCI OWNER FURNISHED-CONTRACTOR
INSTALLED
ORD OVERFLOW ROOF DRAIN
PL PLASTIC LAMINATE
PNL PANEL
PT. PAINT
R / RAD. RADIUS
RAF RAISED ACCESS FLOOR
RD ROOF DRAIN
REF. REFERENCE, REFER TO
REFR. REFRIGERATOR
REINF. REINFORCE (D) (ING)
REQ. REQUIRED
REV. REVISION (S), REVISED
RF RESILIENT FLOORING
RM. ROOM
RO ROUGH OPENING
RP RESIN PANEL
RTU ROOF TOP UNIT
SAB SOUND ATTENUATING BATTS
SCHED. SCHEDULE
SF SQUARE FEET
SIM. SIMILAR
SPEC SPECIFICATION
SS SOLID SURFACE
STD. STANDARD
STL. STEEL
SSTL STAINLESS STEEL
STOR. STORAGE
STRUCT. STRUCTURAL
SUSP. SUSPENDED
TB TACK BOARD
TERR. TERRAZZO
T.O. TOP OF
T.O.B. TOP OF BEAM
T.O.C. TOP OF CONCRETE
T.O.F. TOP OF FOOTING
T.O.W. TOP OF WALL
TWP THROUGH-WALL PENETRATION
TYP. TYPICAL
UVB UNDER-SLAB VAPOR BARRIER
VAR. VARIES
VB VAPOR BARRIER
VERT. VERTICAL
WB WALL BASE
WC WALLCOVERING
WD WOOD
WDF WOOD FLOORING
WDB WOOD BASE
WP WALL PROTECTION
WT WINDOW TREATMENT
EARTH
SITE SPOT ELEVATION
NEW FINISH
SPOT GRADE
NEW / EXISTING WALL CONSTRUCTION COLUMN GRID LINE
NEW AND EXISTING
FINISH SPOT
GRADE
TOP OF CURB
BOT. OF CURB
7.3
N:
7.3
E:
4.8
TC:
7.3
BC:
4.8
EXISTING CONTOUR LINE
NEW CONTOUR LINE
APPROX. TEST BORING LOCATION
PROPERTY LINE
CENTER LINES/ PROJECTED LINES
MATCH LINE
LEVEL LINE
MAIN FLOOR
ELEV. 110'- 0"
ROOM NAME AND NUMBER
DOOR NUMBER
ROOM NUMBER
ALPHABET CHARACTERS USED TO
DISTINGUISH BETWEEN MULTIPLE
DOORS THAT ARE ASSOCIATED WITH
PARTICULAR ROOMS
WINDOW TYPE
KEY NOTES
INDICATES A NOTE FOR A SPECIFIC ITEM
ALL KEY NOTES ARE COMPILED UNDER THE TITLE
BAR "KEY NOTES".
BUILDING SECTION / WALL SECTION
SECTION DIRECTION
DETAIL NUMBER
SHEET NUMBER
DETAILS
DETAIL NUMBER
SHEET NUMBER
EXTERIOR ELEVATION
REVISION MARKER
SHEET NUMBER
ELEVATION NUMBER
ELEVATION DIRECTION
NEW
EXISTING
(SCREENED)
A1.01 1
XX
A
A
A1.01
SIM
NEW
EXISTING
(SCREENED)
OR
INTERIOR ELEVATION
A1.01 1
GRAPHIC SYMBOLS
MATERIAL INDICATIONS
NEW EXISTING
A
A1.01
SIM
SHEET NUMBER
ELEVATION NUMBER
ROOM NAME
150 SF
101 ROOM NUMBER
ROOM SQUARE FOOTAGE
SPOT ELEVATION
8'-0"
TOILET ACCESSORIES TAG
A
WALL TAG ASSEMBLY TYPE TAG
METAL STUDS
METAL SECTION
CMU (STD. WT.)
WOOD STUDS
PLYWOOD
INSULATION
(BLANKET OR BATT)
GLASS FIBER REINFORCED
GYPSUM BOARD
GRAVEL / SAND FILL
CONCRETE
BRICK
STONE
FINISHED WOOD
RIGID INSULATION
SEALANT
GYPSUM BOARD
EXISTING CONSTRUCTION
METAL (LARGE SCALE)
WOOD BLOCKING
ACOUSTICAL CEILING
ELEVATION DIRECTION
W1
101A
101A5 DIGIT
4 DIGIT
B-3
W
B
F
K
ROOM NAME
WALLS
BASE
FLOOR
NOTE
ROOM FINISH TAG
ROOM NAME
ROOM NUMBER
ROOM WALL FINISH
ROOM WALL BASE FINISH
ROOM FLOOR FINISH
ROOM KEYNOTES
MINERAL WOOL SPRAY FOAM AIR SEAL
PROJECT LOCATION
PROFESSIONAL SEALS
ADAM DONAVAN
VAN GORP
07319
S
O
N D
RP
IOWA
L
IC
E E
FESSIONAL
A R
C H
IT
E
C T
Signature
Pages or sheets covered by this seal:
Printed or typed name:
I hereby certify that the portion of this technical submission described below was prepared by me or under my direct supervision and responsible charge. I am a duly Licensed Architect under the laws of the State of
Date
License Number:
My license renewal date is
ARCHITECT
ADAM DONAVAN VAN GORP
07319
JUNE 30TH, 2027
ALL "T" & "A" SHEETS
C M
B A
A R
C H
IT
E
C T
S
G R
A N
D A
V E
S P
E N
C E
R , I
A
(P
) 7
.2
.3
D A
T E
P R
O J
E C
T
PL
O
T D
AT
E
FI
LE
P
AT
H
COPYRIGHT. Permission to reproduce all or part of this drawing is hereby granted solely for the limited purpose of construction of this project or archiving. Unauthorized copying, disclosure or construction use without written permission of Cannon Moss Brygger & Associates is prohibited by copyright law.
SHEET INDEX
REVISIONS
SHEET
/1
/2
:4
7:
A
M
A u to d e sk
D o c s:
D
A S
D O
C N
C C
F E d u c a ti o n B u ild in g
W in d o w R e p la c e m e n t/ D
D A
S D
O C
N C
C F
W in d o w R e p la c e m e n t C e n tr a l.
rv t
.0
T
IT
L E
DAS DOC NCCF EDUCATION BUILDING WINDOW
REPLACEMENT
IOWA DAS
ROCKWELL CITY, IA
T0.01
R O
C K
W E
L L
C
IT
Y , I
A
D A
S D
O C
N C
C F
E D
U C
A T
IO
N
B U
IL
D
IN
G
W
IN
D O
W R
E P
L A
C E
M E
N T
IO
W
A D
A S
GENERAL
T0.01 TITLE
ARCHITECTURAL
A1.00 SITE PLANS
A2.00 FLOOR PLANS
A3.00 EXTERIOR ELEVATIONS & RCP
A5.00 WINDOW AND DETAILS
A5.01 WINDOW DETAILS
OWNERS PROJECT NUMBER: 9496.00
RFP 949600-01
PROJECT SUMMARY
STATE OF IOWA:
OWNER
ARCHITECT
BUILDING OFFICIAL:
REPLACEMENT OF WINDOWS ON THE NORTH CENTRAL CORRECTIONAL FACILITY INDICATED WINDOWS
AS SHOWN ON THE DRAWINGS. REFERENCE FULL BUILDING DRAWINGS FOR CODE INFORMATION
ADDRESSING THE EXISTING BUILDING.
• 2024 IBC: ALL APPLICABLE CHAPTERS
• 2024 International Building Code as adopted by Iowa Administrative Rule chapters 661-201 and 661-301
• 2024 International Fire Code as adopted by Iowa Administrative Rule chapters 661-201
• 2012 International Energy Conservation Code as adopted by Iowa Administrative Rule chapters 661-303
• 2024 International Existing Building Code as adopted by Iowa Administrative Rule chapters 661-301 and 661-350
• 2012 NFPA 101 Life Safety Code as adopted by Iowa Administrative Rule chapter 661-205
• 2010 Americans with Disabilities Act as adopted by Iowa Administrative Rule chapter 661-302
• State Mechanical Code as adopted by the Department of Public Health Iowa Administrative Rule chapter 641-61
• State Plumbing Code as adopted by the Department of Public Health Iowa Administrative Rule chapter 641-25
• State Electrical Code as adopted by the State Electrical Licensing Board Iowa Administrative Rule chapter 661-504
• ANSI 117.1, 2009, ALL APPLICABLE CHAPTERS
Iowa Department of Administrative Services Owner's Representative:
Jennie Elliott State Design & Construction Resources Bureau 109 S.E. 13th Street Des Moines, IA 50319 Office: 515-745-3244
CMBA Architects 505 Grand Avenue Spencer, IA 51301
PH: 712-262-3426
Architect Responsible: Adam Van Gorp, AIA Email: vangorp.a@cmbaarchitects.com
The Iowa Department of Inspections, Appeals, and Licensing, Building & Construction Division
LEVEL 1 ALTERATION: PER IEBC
On Site Contact:
Plant Operations Manager:
Wade Hammen 313 Lanedale Rockwell City, IA 50579
PH: 712-830-5540
IBC 2024 REQ / ALLOWED PROVIDED
USE AND OCCUPANCY
CONSTRUCTION TYPE
AUTOMATIC SPRINKLER SYSTEM
BUILDING HEIGHT
BUILDING STORIES
LARGEST FLOOR AREA / STORY /
1ST FLOOR AREA
CHAPTER 3
SECTION 602 / TABLE 601
SECTION 903
TABLE 504.3
TABLE 504.3
TABLE 506.2
YES
55' MAX
2 STORIES
E
VB
NO
Appx. 35'
NOT TO SCALE
NO. DESCRIPTION DATE
05/01/2026
X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
X
X X
X X
X X
X X
X X
X
X
X
X X
X X
X X
X X
X X
X X
X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
X
X X
X X
X X
X X
X X
X X
X
X
X
X X
X X
X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
X
X
X X
X X
X X
X X
X X
X X
X
X X
X X X X X X X X X X X X X
X
X X
X
X
X X
X X
X X
X X
X X
X X
X
X
X
X X
X X
X X
X X
X
X
X X
X
X
X
X X
X
GENERAL NOTES
KEYNOTES
BUILDING LOCATION
CONTRACTOR PARKING
SALLY PORT - SITE ACCESS ONLY THROUGH THIS GATE
CONTRACTOR TO COORDINATE IN ADVANCE WITH OWNER FOR ALL
GATE PASSING.
SEE SPECIFICATIONS FOR DAILY TOOL INVENTORY REQUIREMENTS.
CONTRACTOR IS RESPONSIBLE FOR HAULING MATERIALS INCLUDING
CONSTRUCTION WASTE IN AND OUT OF THE OUTERMOST FENCED
AREA EACH DAY. MAY BE SUBJECT TO INSPECTION.
PROTECT UNDERGROUND UTILITY LINES IDENTIFIED ON THE SITE
PLAN. VERIFY LOCATION WITH OWNER.
ALL CONTRACTORS PERSONNEL ARE TO HAVE BACKGROUND CHECKS
PRE-APPROVED AND COMPLETE PREA TRAINING BEFORE BEING
ALLOWED ON SITE FOR WORK.
CONTRACTOR TO COORDINATE IN ADVANCE WITH NCCF STAFF FOR
ALL GATE PASSING. GATE LOCATIONS ARE IDENTIFIED IN THE
DOCUMENTS. KEEP GATES CLEAR AT ALL TIMES EXCEPT FOR
COORDINATED PASSING.
ALL WORK AREAS ARE TO BE THOROUGHLY CLEANED AT THE END OF
EACH DAY.
SEE SPECIFICATION FOR DAILY TOOL INVENTORY REQUIREMENTS. A
STANDARDIZED LIST OF DAILY TOOLS ENTERING AND EXITING IS
PREFERRED. ALL CONSTRUCTION EQUIPMENT MUST BE REMOVED
FROM THE SITE DAILY TO THE DESIGNATED STAGING AREA IN THE
PARKING LOT WITH THE EXCEPTION OF A JOB BOX THAT CAN REMAIN
SECURED ON THE ROOF AREA.
SEE SPECIFICATIONS FOR SITE ACCESS, STORAGE, WASTE REMOVAL,
AND WORK HOURS.
PROTECT GRASS AREAS FROM EQUIPMENT AND LIFTS. SEE DRAWING
FOR PROTECTED UNDERGROUND UTILITY LINES. DAMAGE IS THE
RESPONSIBILITY OF THE CONTRACTOR TO REPAIR.
A
B
C
LEGEND
UTILITY AREA - PRESSURE SENSITIVE
D
E
F
G
H
I
J
GATE
FENCE X-X-X-X-X
1" = 20'-0"1
SITE PLAN
C M
B A
A R
C H
IT
E
C T
S
G R
A N
D A
V E
S P
E N
C E
R , I
A
(P
) 7
.2
.3
REVISIONS
SHEET
D A
T E
P R
O J
E C
T
PL
O
T D
AT
E
FI
LE
P
AT
H
COPYRIGHT. Permission to reproduce all or part of this drawing is hereby granted solely for the limited purpose of construction of this project or archiving. Unauthorized copying, disclosure or construction use without written permission of Cannon Moss Brygger & Associates is prohibited by copyright law.
IF THIS DRAWING IS NOT 30"x42" IT IS NOT TO SCALE
/1
/2
:4
7:
A
M
A u to d e sk
D o c s:
D
A S
D O
C N
C C
F E d u c a ti o n B u ild in g
W in d o w R e p la c e m e n t/ D
D A
S D
O C
N C
C F
W in d o w R e p la c e m e n t C e n tr a l.
rv t
A1.00
R O
C K
W E
L L
C
IT
Y , I
A
.0
D A
S D
O C
N C
C F
E D
U C
A T
IO
N
B U
IL
D
IN
G
W
IN
D O
W R
E P
L A
C E
M E
N T
IO
W
A D
A S
S
IT
E P
L A
N S
N
UP
UP
H EADINTERIO R SILL ANG LE INTERIOR JAM B ANG LE
T ypica l 2 P lacesSILL
UP
UP
DEMO PLAN GENERAL NOTES
KEYNOTES
DEMO WINDOW AND ALL TRIM ITEMS
PATCH AREA AROUND WINDOW - SEE ELEVATION 6/A3.00
WINDOW TO HAVE LEVER HANDLES FOR QUICK EXITING (TILT-AND-
TURN). WINDOW TO SWING INWARD.
REMOVE AND REINSTALL STAIR AS REQUIRED TO INSTALL WINDOW.
DASHED LINES INDICATE DEMOLITION. NOT ALL ITEMS NOTED FOR
CLARITY.
EACH CONTRACTOR TO CAREFULLY EXAMINE EXISTING CONDITIONS
PRIOR TO TIME OF BID.
CONTRACTOR SHALL INFILL, OR PATCH AND REPAIR ANY OPENING IN
EXISTING WALLS AS REQUIRED TO MAINTAIN EXISTING OR NEW RATED
CONSTRUCTION.
PATCH AND REPAIR EXISTING SURFACES, INDICATED TO REMAIN,
DAMAGED DURING DEMOLITION. PREPARE FOR INSTALLATION OF NEW
FINISHES AS SPECIFIED.
PROTECT EXISTING FINISHES TO REMAIN.
FINISHES AND OTHER ITEMS INDICATED FOR DEMOLITION SHALL BE
ADEQUATELY REMOVED TO PROVIDE A SUITABLE SUBSTRATE FOR THE
INSTALLATION OF PROPOSED MATERIALS AND FINISHES.
MAINTAIN WEATHER TIGHT CONDITIONS ON ALL EXISTING SPACES
THROUGHOUT CONSTRUCTION.
OWNER WILL REMOVE ALL WINDOW COVERINGS
OWNER WILL MOVE FURNITURE AND EQUIPMENT TO MAKE WAY FOR
WORK TO BE PERFORMED
COORDINATE PHASING OF DEMOLITION WITH OWNER ROOM BY ROOM
REMOVE AND REPLACE ANY ROTTEN / COMPROMISED SUBSTRATES OR
FRAMING.
OWNER WILL REMOVE WINDOW AC UNITS AND FANS. OWNER WILL
REINSTALL WINDOW AC AND FANS.
A
B
C
D
E
FLOOR PLAN GENERAL NOTES
SEE SHEET T0.01 FOR ALL NOTES AND ABBREVIATIONS
CONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS AND NOTIFY
ARCHITECT OF ANY DISCREPANCIES PRIOR TO BEGINNING THE
AFFECTED WORK.
DO NOT SCALE DRAWINGS, FOLLOW DIMENSIONS.
PATCH AND REPAIR EXISTING WALLS, FLOORS, CEILINGS, ETC., THAT
ARE SHOWN TO REMAIN BUT ARE DAMAGED DUE TO CONSTRUCTION
WORK. THIS SHALL INCLUDE REPAIRING FINISHES DAMAGED BY THE
REMOVAL OR INSTALLATION OF NEW MECHANICAL, ELECTRICAL, OR
FIRE PROTECTION WORK OR DEVICES.
COORDINATE PHASING OF PLACING WINDOWS WITH OWNER ROOM BY
ROOM.
A
B
C
D
E
F
G
H
I
J
A3.00
A3.00
A3.00
A3.00
ED2-21
ED2-26
ED2-12
ED2-18
ED2-17
ED2-16
ED3-11
ED2-19D.1
A A A A
B
J
AAAA
D.1
E
D
A3.00
A3.00
A3.00
A3.00
ED1-13
ED1-12
ED1-17
F I H I
A3.00
A3.00
A3.00
A3.00
A.1A.1ACC
C.1
D.1
D
D D A.1 A.1
D
ED3-24
ED3-19
RD3-20
ED3-18
ED3-15
ED3-14
ED3-12
ED3-30
C
ED1-13
ED1-12 ED1-17
11 1 1 1
ED2-12
ED2-26
ED2-21
ED2-19
ED2-18
ED2-18
ED2-16
ED3-11
ED3-18
RD3-20
ED3-19
ED3-24
ED3-30
ED3-12
ED3-15
ED3-14
1 1 1 1 1 1
1/8" = 1'-0"2
FLOOR 02 - DEMO
1/8" = 1'-0"5 Floor 02
C M
B A
A R
C H
IT
E
C T
S
G R
A N
D A
V E
S P
E N
C E
R , I
A
(P
) 7
.2
.3
REVISIONS
SHEET
D A
T E
P R
O J
E C
T
PL
O
T D
AT
E
FI
LE
P
AT
H
COPYRIGHT. Permission to reproduce all or part of this drawing is hereby granted solely for the limited purpose of construction of this project or archiving. Unauthorized copying, disclosure or construction use without written permission of Cannon Moss Brygger & Associates is prohibited by copyright law.
IF THIS DRAWING IS NOT 30"x42" IT IS NOT TO SCALE
/1
/2
:4
7:
A
M
A u to d e sk
D o c s:
D
A S
D O
C N
C C
F E d u c a ti o n B u ild in g
W in d o w R e p la c e m e n t/ D
D A
S D
O C
N C
C F
W in d o w R e p la c e m e n t C e n tr a l.
rv t
A2.00
R O
C K
W E
L L
C
IT
Y , I
A
.0
D A
S D
O C
N C
C F
E D
U C
A T
IO
N
B U
IL
D
IN
G
W
IN
D O
W R
E P
L A
C E
M E
N T
IO
W
A D
A S
F L
O O
R P
L A
N S
1/8" = 1'-0"6 Floor 01
1/8" = 1'-0"4
FLOOR 3 - RCP
1/8" = 1'-0"3 Floor 01 - DEMO
1/8" = 1'-0"1 Floor 03 - DEMO
N
N
NN
N
N
GENERAL NOTES
KEYNOTES
PREP WINDOW WITHOUT NAILING FLANGE AS NEEDED.
WINDOW TO HAVE LEVER HANDLES FOR QUICK EXITING (TILT-AND-
TURN). WINDOW TO SWING INWARD.
COMPOSITE TRIM
SOLID SURFACE SILL
BISCUIT JOIN AND GLUE JOINTS TOGETHER
MECHANICAL AND ELECTRICAL EQUIPMENT AND COMPONENTS ARE
ILLUSTRATED FOR CONTEXT AND COORDINATION PURPOSES ONLY. SEE
MECHANICAL AND ELECTRICAL DOCUMENTS.
PROVIDE PROPER ANCHORAGE OF ALL WALL-ATTACHED ITEMS
MAINTAINING THE CONTINUITY OF THE COMPLETE AIR/MOISTURE
BARRIER.
ALL EXTERIOR WALL ASSEMBLIES SHALL BE PROPERLY FLASHED AND
SEALED WEATHER-TIGHT .
ENSURE ALL WEEPS, THRU WALL FLASHING AND OTHER DRAINAGE
CAVITIES REMAIN OPEN TO ALLOW CONDENSATION AND MOISTURE TO
ESCAPE. SEALANT SHALL BE APPLIED TO THE UNDERSIDE OF ALL
FLASHING AND DRIPS.
EIFS TRIM TO BE PAINTED TO MATCH THE ADJACENT EXISTING EIFS
COLOR.
EXTERIOR STAIRS TO REMAIN CLEAR AT ALL TIMES FOR EXITING
PURPOSES.
A
B
C
D
E
F
LEGEND
EXISTING WALL MOUNTED AIR CONDITIONER TO REMAIN
REMOVE AND REPLACE DAMAGED WALL PLASTER.
- REPLACE WITH GYPSUM BOARD.
- TEXTURE TO MATCH EXISTING WALL.
- PRIME ONLY, OWNER WILL PAINT
J B
B.1B.1 A.1A.1
A A A A
DD
A.1
A A
A.1
A
A
A
CC
F
DC
L
I H I
K
H
D.1 D.1 E
D.1D
C.1
H
D
G
B
8' - 5 1/2"
A.1 A.1
A.1A.1
ED3-24
V A
R
IE
S V
A R
IE
S
/2
5 1/2" VARIES 5 1/2"
6" VARIES 6"
V A
R
IE
S
C M
B A
A R
C H
IT
E
C T
S
G R
A N
D A
V E
S P
E N
C E
R , I
A
(P
) 7
.2
.3
REVISIONS
SHEET
D A
T E
P R
O J
E C
T
PL
O
T D
AT
E
FI
LE
P
AT
H
COPYRIGHT. Permission to reproduce all or part of this drawing is hereby granted solely for the limited purpose of construction of this project or archiving. Unauthorized copying, disclosure or construction use without written permission of Cannon Moss Brygger & Associates is prohibited by copyright law.
IF THIS DRAWING IS NOT 30"x42" IT IS NOT TO SCALE
/1
/2
:4
7:
A
M
A u to d e sk
D o c s:
D
A S
D O
C N
C C
F E d u c a ti o n B u ild in g
W in d o w R e p la c e m e n t/ D
D A
S D
O C
N C
C F
W in d o w R e p la c e m e n t C e n tr a l.
rv t
A3.00
R O
C K
W E
L L
C
IT
Y , I
A
.0
D A
S D
O C
N C
C F
E D
U C
A T
IO
N
B U
IL
D
IN
G
W
IN
D O
W R
E P
L A
C E
M E
N T
IO
W
A D
A S
E X
T E
R
IO
R E
L E
V A
T
IO
N S
R
C P
1/8" = 1'-0"1 East
1/8" = 1'-0"2 North
1/8" = 1'-0"4 South
1/8" = 1'-0"3 West
1/8" = 1'-0"7
FLOOR 3 - RCP
1/2" = 1'-0"6
TYP. INTERIOR PATCH
1/2" = 1'-0"5
TYP. INTERIOR TRIM
A5.00
A5.00
V
IF
6'
V
IF
3'
VIF.
2' - 6"
A5.00
IG
6"
MIN.
1/4"
V
IF
/4
6"
6"
M
IN
1/
VIF.
7 1/4" 6"
6"
M
IN
1/
VIF.
7 1/4" 6"
A5.00
A5.00
A5.00
V
IF
VIF.
3'-6"
IG
V
IF
3'
V
IF
3'
VIF.
2' - 1"
A5.00
A5.00
A5.00
IG
A5.01
A5.01
A5.01
V
IF
V
IF
2"
VIF.
2'-3" 2"
IP
V
IF
V
IF
VIF.
3' - 1"
A5.00
A5.00
A5.00
IG
1'
/2
8' - 5 1/2"
6"
M
IN
1/
VIF.
7 1/4" 6"
A5.00
A5.00
A5.00
V
IF
6'
V
IF
3'
VIF.
2' - 6"
IG
GENERAL NOTES
ALL EXTERIOR BLOCKING TO BE MOISTURE TREATED (EXTERIOR
ROUGH OPENINGS, AND ANY WOOD IN CONTRACT WITH CONCRETE).
ENSURE ALL WEEPS, THRU WALL FLASHING AND OTHER DRAINAGE
CAVITIES REMAIN OPEN TO ALLOW CONDENSATION AND MOISTURE TO
ESCAPE. SEALANT SHALL BE APPLIED TO THE UNDERSIDE OF ALL
FLASHING AND DRIPS.
FIELD VERIFY EXISTING CONDITIONS IN CONJUNCTION WITH NEW
CONSTRUCTION. NOTIFY ARCHITECT OF DISCREPANCIES.
ALL EXTERIOR WALL TYPES ARE SHOWN IN GRAY FOR REFERENCE
ONLY, VERIFY WALL MAKEUP AND DIMENSIONS IN FIELD.
SHIM WINDOWS WITH EITHER CEDAR WOOD, TREATED WOOD, OR
PLASTIC SHIMS.
FOAM IN PLACE ALL VOIDS AROUND WINDOW TO PROVIDE A
CONTINUOUS INSULATION BARRIER BETWEEN THE WINDOW AND THE
WALL.
ALL BLOCKING TO BE MECHANICALLY FASTENED AND SET IN
ADHESIVE.
VERIFY ALL OPENING SIZES IN FIELD, SIZES MAY VARY. WHEN SIZING
WINDOWS ACCOUNT FOR BLOCKING AND SHIMMING.
ALL WINDOW GRIDS WILL BE BID AS ALTERNATE 1.
A
B
C
D
KEYNOTES
EXISTING WALL
WINDOW AS SCHEDULED - VERIFY ALL SIZES IN FIELD.
BACKER ROD AND SEALANT
BLOCKING AS REQUIRED - TREATED
SOLID SURFACE SILL
SEALANT
COMPOSITE EXTENSION JAMB - VERIFY WALL DEPTH IN FIELD
EIFS SYSTEM
PREFINISHED ALUMINUM FLASHING - COLOR TO MATCH WINDOW
FRAME
FLASHING TAPE
INSULATION 6" X 3"
EXISTING WEATHER BARRIER
WEATHER BARRIER - TO WRAP INTO OPENING
PLASTER FINISH - PATCH BACK AS NEEDED
WINDOW NAILING FLANGE - SET IN SEALANT AND MECHANICALLY
FASTENED
COMPOSITE WINDOW TRIM
SHIM AS REQUIRED
WINDOW HARDWARE
ALUMINUM BREAK METAL WRAP - COLOR TO MATCH WINDOW FRAME
MULLED WINDOW JOINT
MAXIMIZE LOWER WINDOW SIZE - REMOVE UPPER WINDOW IF
POSSIBLE.
E
F
G
H
LEGEND
IP - INSULATED PANEL - PROVIDE TWO PANELS PER WINDOW
RF - INSULATED FIRE RATED GLAZING
IG - INSULATED GLAZING
I
6"
M
IN
1/
VIF.
7 5/8" 6"
6"
MIN.
1/4"
V
IF
/8
6"
6"
M
IN
1/
VIF.
7 5/8" 6"
A5.00
A5.00
A5.01
V
IF
V
IF
/4
VIF.
2'-1"
IG
V
IF
V
IF
2"
VIF.
2'-9" 2"
A5.01
A5.01
A5.01
IP
A5.01
A5.01
A5.01
V
IF
/2
V
IF
2"
VIF.
1'-9" 2"
IP
V
IF
F
IV
VIF.
2'-1"
A5.01
A5.01
A5.01
FR
A5.01
A5.01
A5.01
V
IF
VIF.
3'-6"
FR
V
IF
3'
V
IF
3'
VIF.
2' - 1"
A5.01
A5.01
A5.01
FR
V
IF
V
IF
VIF.
2'-7"
A5.01
A5.01
A5.00
FR
V A
R Y
M A
Y
H E
IG
H
T
M A
X
IM
IZ
E
V
IF
V
IF
A5.01
A5.01
A5.01
FR
FR
V A
R Y
M A
Y
H E
IG
H
T
M A
X
IM
IZ
E
V
IF
V
IF
A5.01
A5.01
A5.01
FR
FR
V A
R Y
M A
Y
H E
IG
H
T
M A
X
IM
IZ
E
V
IF
V
IF
A5.01
A5.01
A5.01
FR
FR
C M
B A
A R
C H
IT
E
C T
S
G R
A N
D A
V E
S P
E N
C E
R , I
A
(P
) 7
.2
.3
REVISIONS
SHEET
D A
T E
P R
O J
E C
T
PL
O
T D
AT
E
FI
LE
P
AT
H
COPYRIGHT. Permission to reproduce all or part of this drawing is hereby granted solely for the limited purpose of construction of this project or archiving. Unauthorized copying, disclosure or construction use without written permission of Cannon Moss Brygger & Associates is prohibited by copyright law.
IF THIS DRAWING IS NOT 30"x42" IT IS NOT TO SCALE
/1
/2
:4
7:
A
M
A u to d e sk
D o c s:
D
A S
D O
C N
C C
F E d u c a ti o n B u ild in g
W in d o w R e p la c e m e n t/ D
D A
S D
O C
N C
C F
W in d o w R e p la c e m e n t C e n tr a l.
rv t
A5.00
R O
C K
W E
L L
C
IT
Y , I
A
.0
D A
S D
O C
N C
C F
E D
U C
A T
IO
N
B U
IL
D
IN
G
W
IN
D O
W R
E P
L A
C E
M E
N T
IO
W
A D
A S
W
IN
D O
W A
N D
D E
T A
IL
S
WINDOWS
WINDOW A
3" = 1'-0"6
JAMB
3" = 1'-0"5
HEAD
3" = 1'-0"7
SILL
WINDOW C WINDOW D
WINDOW IWINDOW F
3" = 1'-0"1
A.1 HEAD
WINDOW A.1
3" = 1'-0"2
HEAD
3" = 1'-0"3
JAMB
3" = 1'-0"4 Detail 3
WINDOW L
WINDOW H
WINDOW K
WINDOW EWINDOW C.1 WINDOW D.1
FIRE RATED FIRE RATED
FIRE RATED FIRE RATED FIRE RATED
WINDOW G
FIRE RATED
WINDOW J
EGRES -FIRE RATED
WINDOW B WINDOW B.1
6"
M
IN
1/
VIF.
7 1/4" 6"
6"
MIN.
1/4"
6"
V
IF
/4
6"
M
IN
1/
7 1/4" 6"
GENERAL NOTES
ALL EXTERIOR BLOCKING TO BE MOISTURE TREATED (EXTERIOR
ROUGH OPENINGS, AND ANY WOOD IN CONTRACT WITH CONCRETE).
ENSURE ALL WEEPS, THRU WALL FLASHING AND OTHER DRAINAGE
CAVITIES REMAIN OPEN TO ALLOW CONDENSATION AND MOISTURE TO
ESCAPE. SEALANT SHALL BE APPLIED TO THE UNDERSIDE OF ALL
FLASHING AND DRIPS.
FIELD VERIFY EXISTING CONDITIONS IN CONJUNCTION WITH NEW
CONSTRUCTION. NOTIFY ARCHITECT OF DISCREPANCIES.
ALL EXTERIOR WALL TYPES ARE SHOWN IN GRAY FOR REFERENCE
ONLY, VERIFY WALL MAKEUP AND DIMENSIONS IN FIELD.
SHIM WINDOWS WITH EITHER CEDAR WOOD, TREATED WOOD, OR
PLASTIC SHIMS.
FOAM IN PLACE ALL VOIDS AROUND WINDOW TO PROVIDE A
CONTINUOUS INSULATION BARRIER BETWEEN THE WINDOW AND THE
WALL.
ALL BLOCKING TO BE MECHANICALLY FASTENED AND SET IN
ADHESIVE.
VERIFY ALL OPENING SIZES IN FIELD, SIZES MAY VARY. WHEN SIZING
WINDOWS ACCOUNT FOR BLOCKING AND SHIMMING.
ALL WINDOW GRIDS WILL BE BID AS ALTERNATE 1.
A
B
C
D
KEYNOTES
EXISTING WALL
WINDOW AS SCHEDULED - VERIFY ALL SIZES IN FIELD.
BACKER ROD AND SEALANT
BLOCKING AS REQUIRED - TREATED
SOLID SURFACE SILL
SEALANT
COMPOSITE EXTENSION JAMB - VERIFY WALL DEPTH IN FIELD
EIFS SYSTEM
PREFINISHED ALUMINUM FLASHING - COLOR TO MATCH WINDOW
FRAME
FLASHING TAPE
INSULATION 6" X 3"
EXISTING WEATHER BARRIER
WEATHER BARRIER - TO WRAP INTO OPENING
PLASTER FINISH - PATCH BACK AS NEEDED
WINDOW NAILING FLANGE - SET IN SEALANT AND MECHANICALLY
FASTENED
COMPOSITE WINDOW TRIM
SHIM AS REQUIRED
WINDOW HARDWARE
ALUMINUM BREAK METAL WRAP - COLOR TO MATCH WINDOW FRAME
MULLED WINDOW JOINT
MAXIMIZE LOWER WINDOW SIZE - REMOVE UPPER WINDOW IF
POSSIBLE.
E
F
G
H
LEGEND
IP - INSULATED PANEL - PROVIDE TWO PANELS PER WINDOW
RF - INSULATED FIRE RATED GLAZING
IG - INSULATED GLAZING
I
6"
MIN.
1/4"
6"
/8
/4
6"
M
IN
1/
VIF.
9 1/8" 2 3/4"
6"
M
IN
1/
9 1/8" 2 3/4"
1'
7/
8' - 5 1/2"
6"
M
IN
1/
9 1/8" 2 3/4"
C M
B A
A R
C H
IT
E
C T
S
G R
A N
D A
V E
S P
E N
C E
R , I
A
(P
) 7
.2
.3
REVISIONS
SHEET
D A
T E
P R
O J
E C
T
PL
O
T D
AT
E
FI
LE
P
AT
H
COPYRIGHT. Permission to reproduce all or part of this drawing is hereby granted solely for the limited purpose of construction of this project or archiving. Unauthorized copying, disclosure or construction use without written permission of Cannon Moss Brygger & Associates is prohibited by copyright law.
IF THIS DRAWING IS NOT 30"x42" IT IS NOT TO SCALE
/1
/2
:4
7:
A
M
A u to d e sk
D o c s:
D
A S
D O
C N
C C
F E d u c a ti o n B u ild in g
W in d o w R e p la c e m e n t/ D
D A
S D
O C
N C
C F
W in d o w R e p la c e m e n t C e n tr a l.
rv t
A5.01
R O
C K
W E
L L
C
IT
Y , I
A
.0
D A
S D
O C
N C
C F
E D
U C
A T
IO
N
B U
IL
D
IN
G
W
IN
D O
W R
E P
L A
C E
M E
N T
IO
W
A D
A S
W
IN
D O
W D
E T
A
IL
S
3" = 1'-0"6
HEAD
3" = 1'-0"7
JAMB
3" = 1'-0"8
SILL
3" = 1'-0"1
WINODW G & H
3" = 1'-0"4
JAMB
3" = 1'-0"5
SILL
3" = 1'-0"3
HEAD
3" = 1'-0"2
HEAD
| Sheets |
| T0.01 - TITLE |
| A1.00 - SITE PLANS |
| A2.00 - FLOOR PLANS |
| A3.00 - EXTERIOR ELEVATIONS & RCP |
| A5.00 - WINDOW AND DETAILS |
| A5.01 - WINDOW DETAILS |
File details come from the government source that posted it. Updated .