RFB949600-01 - Drawings.pdf

PDF 2 MB Posted

Attached to
DOC North Central Correctional Facility Replace Windows in Education Building
Solicitation number
RFB949600-01
Issued by
Carroll County, Iowa

About this file

This is a Request for Bids (RFB949600-01) issued by the Iowa Department of Administrative Services (DAS) on behalf of the Iowa Department of Corrections (DOC) for the replacement of windows in the Education Building at North Central Correctional Facility located in Rockwell City, Iowa. The project encompasses the demolition and replacement of existing windows throughout the facility, with contractors responsible for providing all materials, labor, and installation services. The scope includes window removal, substrate preparation, installation of new windows with proper flashing and sealing, interior patching and finishing, and site cleanup. Specific window types are designated throughout the facility on Floors 1, 2, and 3, with detailed specifications and dimensions provided in the architectural drawings. The bid due date is June 1, 2026, at 2:00 PM CDT, with bid opening scheduled for May 7, 2026, at 9:30 AM CDT. All prospective bidders must review the complete project manual, drawings, and bid requirements available for download, with questions directed to Michael Bradbury at michael.bradbury@das.iowa.gov or +1 515-823-9327.

Bid security in the form of a bond equal to 5% of the total bid amount is required with each submission. The State of Iowa actively seeks subcontractor participation from Targeted Small Businesses in accordance with Chapter 73 of the Code of Iowa; bidders must submit detailed pre-bid contract information identifying all subcontractors and corresponding dollar amounts. The project is classified under commodity codes related to building construction services, glass and windows, and doors and windows installation, allowing qualified contractors in these specializations to compete. No incumbent vendors or specific technology integration requirements are identified. The specific budget or award value has not been disclosed in the RFB notice; interested bidders should contact the procurement contact for additional financial details or consult the complete project manual for estimated costs. All contractor personnel are required to complete background checks and PREA training prior to site access, and all work must comply with applicable Iowa codes including the 2024 International Building Code and related standards.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ABBREVIATIONS

AB AIR BARRIER

AFF ABOVE FINISH FLOOR

ACT ACOUSTICAL CEILING TILE

ALT. ALTERNATE

ALUM. ALUMINUM

APPROX. APPROXIMATE

ARCH. ARCHITECT (URAL)

AVB AIR AND VAPOR BARRIER

BD. BOARD

BES BUILDING ENVELOPE SEALANT

BG BUMPER GUARD

BGW BELOW GRADE WATERPROOFING

MEMBRANE

B.O. BOTTOM OF

BRG. BEARING

CC CUBICLE CURTAIN

CFCI CONTRACTOR FURNISHED-CONTRACTOR

INSTALLED

CG CORNER GUARD

CJ CONTROL JOINT

CL CENTERLINE

CLG. CEILING

CMU CONCRETE MASONRY UNIT

COL. COLUMN

CONC. CONCRETE

CONST. CONSTRUCTION

CONT. CONTINUOUS

CORR. CORRIDOR

CPT. CARPET

CR CHAIR RAIL

CT CERAMIC TILE

DIA. DIAMETER

DIM. DIMENSION

DN. DOWN

DS DOWNSPOUT

DTL. DETAIL

DVB DECK VAPOR BARRIER

DWG. DRAWING

EA. EACH

EG END GUARD

EJ EXPANSION JOINT

ELEC. ELECTRICAL

ELEV. ELEVATOR

EPT EPOXY PAINT

EQ. EQUAL

EQUIP. EQUIPMENT

EW EACH WAY

EXIST. EXISTING

EXP. EXPOSED

EXT. EXTERIOR

FAF FLUID APPLIED FLOORING

FD FLOOR DRAIN

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FIN. FINISH (ED)

FLR. FLOOR

FND. FOUNDATION

FRP FIBERGLASS REINFORCED PANEL

FRT FIRE RETARDANT TREATED

FTG. FOOTING

FV FIELD VERIFY

GA. GAUGE

GALV. GALVANIZED

GC GENERAL CONTRACTOR

GFRG GLASS FIBER REINFORCED GYPSUM

GL GLASS

GYP. GYPSUM

GWB GYPSUM WALL BOARD

HM HOLLOW METAL

HORIZ. HORIZONTAL

HR HANDRAIL

HVAC HEATING, VENTILATING, AIR CONDITIONING

INT. INTERIOR

JST. JOIST

JT. JOINT

KIT. KITCHEN

LAV. LAVATORY

MAX. MAXIMUM

MB MARKER BOARD

MDF MEDIUM DENSITY FIBERBOARD

MECH. MECHANICAL

MFR. MANUFACTURER

MIN. MINIMUM

MISC. MISCELLANEOUS

MTL. METAL

NIC NOT IN CONTRACT

NOM. NOMINAL

NTS NOT TO SCALE

OC ON CENTER

OFOI OWNER FURNISHED-OWNER INSTALLED

OFCI OWNER FURNISHED-CONTRACTOR

INSTALLED

ORD OVERFLOW ROOF DRAIN

PL PLASTIC LAMINATE

PNL PANEL

PT. PAINT

R / RAD. RADIUS

RAF RAISED ACCESS FLOOR

RD ROOF DRAIN

REF. REFERENCE, REFER TO

REFR. REFRIGERATOR

REINF. REINFORCE (D) (ING)

REQ. REQUIRED

REV. REVISION (S), REVISED

RF RESILIENT FLOORING

RM. ROOM

RO ROUGH OPENING

RP RESIN PANEL

RTU ROOF TOP UNIT

SAB SOUND ATTENUATING BATTS

SCHED. SCHEDULE

SF SQUARE FEET

SIM. SIMILAR

SPEC SPECIFICATION

SS SOLID SURFACE

STD. STANDARD

STL. STEEL

SSTL STAINLESS STEEL

STOR. STORAGE

STRUCT. STRUCTURAL

SUSP. SUSPENDED

TB TACK BOARD

TERR. TERRAZZO

T.O. TOP OF

T.O.B. TOP OF BEAM

T.O.C. TOP OF CONCRETE

T.O.F. TOP OF FOOTING

T.O.W. TOP OF WALL

TWP THROUGH-WALL PENETRATION

TYP. TYPICAL

UVB UNDER-SLAB VAPOR BARRIER

VAR. VARIES

VB VAPOR BARRIER

VERT. VERTICAL

WB WALL BASE

WC WALLCOVERING

WD WOOD

WDF WOOD FLOORING

WDB WOOD BASE

WP WALL PROTECTION

WT WINDOW TREATMENT

EARTH

SITE SPOT ELEVATION

NEW FINISH

SPOT GRADE

NEW / EXISTING WALL CONSTRUCTION COLUMN GRID LINE

NEW AND EXISTING

FINISH SPOT

GRADE

TOP OF CURB

BOT. OF CURB

7.3

N:

7.3

E:

4.8

TC:

7.3

BC:

4.8

EXISTING CONTOUR LINE

NEW CONTOUR LINE

APPROX. TEST BORING LOCATION

PROPERTY LINE

CENTER LINES/ PROJECTED LINES

MATCH LINE

LEVEL LINE

MAIN FLOOR

ELEV. 110'- 0"

ROOM NAME AND NUMBER

DOOR NUMBER

ROOM NUMBER

ALPHABET CHARACTERS USED TO

DISTINGUISH BETWEEN MULTIPLE

DOORS THAT ARE ASSOCIATED WITH

PARTICULAR ROOMS

WINDOW TYPE

KEY NOTES

INDICATES A NOTE FOR A SPECIFIC ITEM

ALL KEY NOTES ARE COMPILED UNDER THE TITLE

BAR "KEY NOTES".

BUILDING SECTION / WALL SECTION

SECTION DIRECTION

DETAIL NUMBER

SHEET NUMBER

DETAILS

DETAIL NUMBER

SHEET NUMBER

EXTERIOR ELEVATION

REVISION MARKER

SHEET NUMBER

ELEVATION NUMBER

ELEVATION DIRECTION

NEW

EXISTING

(SCREENED)

A1.01 1

XX

A

A

A1.01

SIM

NEW

EXISTING

(SCREENED)

OR

INTERIOR ELEVATION

A1.01 1

GRAPHIC SYMBOLS

MATERIAL INDICATIONS

NEW EXISTING

A

A1.01

SIM

SHEET NUMBER

ELEVATION NUMBER

ROOM NAME

150 SF

101 ROOM NUMBER

ROOM SQUARE FOOTAGE

SPOT ELEVATION

8'-0"

TOILET ACCESSORIES TAG

A

WALL TAG ASSEMBLY TYPE TAG

METAL STUDS

METAL SECTION

CMU (STD. WT.)

WOOD STUDS

PLYWOOD

INSULATION

(BLANKET OR BATT)

GLASS FIBER REINFORCED

GYPSUM BOARD

GRAVEL / SAND FILL

CONCRETE

BRICK

STONE

FINISHED WOOD

RIGID INSULATION

SEALANT

GYPSUM BOARD

EXISTING CONSTRUCTION

METAL (LARGE SCALE)

WOOD BLOCKING

ACOUSTICAL CEILING

ELEVATION DIRECTION

W1

101A

101A5 DIGIT

4 DIGIT

B-3

W

B

F

K

ROOM NAME

WALLS

BASE

FLOOR

NOTE

ROOM FINISH TAG

ROOM NAME

ROOM NUMBER

ROOM WALL FINISH

ROOM WALL BASE FINISH

ROOM FLOOR FINISH

ROOM KEYNOTES

MINERAL WOOL SPRAY FOAM AIR SEAL

PROJECT LOCATION

PROFESSIONAL SEALS

ADAM DONAVAN

VAN GORP

07319

S

O

N D

RP

IOWA

L

IC

E E

FESSIONAL

A R

C H

IT

E

C T

Signature

Pages or sheets covered by this seal:

Printed or typed name:

I hereby certify that the portion of this technical submission described below was prepared by me or under my direct supervision and responsible charge. I am a duly Licensed Architect under the laws of the State of

Date

License Number:

My license renewal date is

ARCHITECT

ADAM DONAVAN VAN GORP

07319

JUNE 30TH, 2027

ALL "T" & "A" SHEETS

C M

B A

A R

C H

IT

E

C T

S

G R

A N

D A

V E

S P

E N

C E

R , I

A

(P

) 7

.2

.3

D A

T E

P R

O J

E C

T

PL

O

T D

AT

E

FI

LE

P

AT

H

COPYRIGHT. Permission to reproduce all or part of this drawing is hereby granted solely for the limited purpose of construction of this project or archiving. Unauthorized copying, disclosure or construction use without written permission of Cannon Moss Brygger & Associates is prohibited by copyright law.

SHEET INDEX

REVISIONS

SHEET

/1

/2

:4

7:

A

M

A u to d e sk

D o c s:

D

A S

D O

C N

C C

F E d u c a ti o n B u ild in g

W in d o w R e p la c e m e n t/ D

D A

S D

O C

N C

C F

W in d o w R e p la c e m e n t C e n tr a l.

rv t

.0

T

IT

L E

DAS DOC NCCF EDUCATION BUILDING WINDOW

REPLACEMENT

IOWA DAS

ROCKWELL CITY, IA

T0.01

R O

C K

W E

L L

C

IT

Y , I

A

D A

S D

O C

N C

C F

E D

U C

A T

IO

N

B U

IL

D

IN

G

W

IN

D O

W R

E P

L A

C E

M E

N T

IO

W

A D

A S

GENERAL

T0.01 TITLE

ARCHITECTURAL

A1.00 SITE PLANS

A2.00 FLOOR PLANS

A3.00 EXTERIOR ELEVATIONS & RCP

A5.00 WINDOW AND DETAILS

A5.01 WINDOW DETAILS

OWNERS PROJECT NUMBER: 9496.00

RFP 949600-01

PROJECT SUMMARY

STATE OF IOWA:

OWNER

ARCHITECT

BUILDING OFFICIAL:

REPLACEMENT OF WINDOWS ON THE NORTH CENTRAL CORRECTIONAL FACILITY INDICATED WINDOWS

AS SHOWN ON THE DRAWINGS. REFERENCE FULL BUILDING DRAWINGS FOR CODE INFORMATION

ADDRESSING THE EXISTING BUILDING.

• 2024 IBC: ALL APPLICABLE CHAPTERS

• 2024 International Building Code as adopted by Iowa Administrative Rule chapters 661-201 and 661-301

• 2024 International Fire Code as adopted by Iowa Administrative Rule chapters 661-201

• 2012 International Energy Conservation Code as adopted by Iowa Administrative Rule chapters 661-303

• 2024 International Existing Building Code as adopted by Iowa Administrative Rule chapters 661-301 and 661-350

• 2012 NFPA 101 Life Safety Code as adopted by Iowa Administrative Rule chapter 661-205

• 2010 Americans with Disabilities Act as adopted by Iowa Administrative Rule chapter 661-302

• State Mechanical Code as adopted by the Department of Public Health Iowa Administrative Rule chapter 641-61

• State Plumbing Code as adopted by the Department of Public Health Iowa Administrative Rule chapter 641-25

• State Electrical Code as adopted by the State Electrical Licensing Board Iowa Administrative Rule chapter 661-504

• ANSI 117.1, 2009, ALL APPLICABLE CHAPTERS

Iowa Department of Administrative Services Owner's Representative:

Jennie Elliott State Design & Construction Resources Bureau 109 S.E. 13th Street Des Moines, IA 50319 Office: 515-745-3244

CMBA Architects 505 Grand Avenue Spencer, IA 51301

PH: 712-262-3426

Architect Responsible: Adam Van Gorp, AIA Email: vangorp.a@cmbaarchitects.com

The Iowa Department of Inspections, Appeals, and Licensing, Building & Construction Division

LEVEL 1 ALTERATION: PER IEBC

On Site Contact:

Plant Operations Manager:

Wade Hammen 313 Lanedale Rockwell City, IA 50579

PH: 712-830-5540

IBC 2024 REQ / ALLOWED PROVIDED

USE AND OCCUPANCY

CONSTRUCTION TYPE

AUTOMATIC SPRINKLER SYSTEM

BUILDING HEIGHT

BUILDING STORIES

LARGEST FLOOR AREA / STORY /

1ST FLOOR AREA

CHAPTER 3

SECTION 602 / TABLE 601

SECTION 903

TABLE 504.3

TABLE 504.3

TABLE 506.2

YES

55' MAX

2 STORIES

E

VB

NO

Appx. 35'

NOT TO SCALE

NO. DESCRIPTION DATE

05/01/2026

X

X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X

X

X X

X X

X X

X X

X X

X

X

X

X X

X X

X X

X X

X X

X X

X

X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X

X

X X

X X

X X

X X

X X

X X

X

X

X

X X

X X

X

X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X

X

X

X X

X X

X X

X X

X X

X X

X

X X

X X X X X X X X X X X X X

X

X X

X

X

X X

X X

X X

X X

X X

X X

X

X

X

X X

X X

X X

X X

X

X

X X

X

X

X

X X

X

GENERAL NOTES

KEYNOTES

BUILDING LOCATION

CONTRACTOR PARKING

SALLY PORT - SITE ACCESS ONLY THROUGH THIS GATE

CONTRACTOR TO COORDINATE IN ADVANCE WITH OWNER FOR ALL

GATE PASSING.

SEE SPECIFICATIONS FOR DAILY TOOL INVENTORY REQUIREMENTS.

CONTRACTOR IS RESPONSIBLE FOR HAULING MATERIALS INCLUDING

CONSTRUCTION WASTE IN AND OUT OF THE OUTERMOST FENCED

AREA EACH DAY. MAY BE SUBJECT TO INSPECTION.

PROTECT UNDERGROUND UTILITY LINES IDENTIFIED ON THE SITE

PLAN. VERIFY LOCATION WITH OWNER.

ALL CONTRACTORS PERSONNEL ARE TO HAVE BACKGROUND CHECKS

PRE-APPROVED AND COMPLETE PREA TRAINING BEFORE BEING

ALLOWED ON SITE FOR WORK.

CONTRACTOR TO COORDINATE IN ADVANCE WITH NCCF STAFF FOR

ALL GATE PASSING. GATE LOCATIONS ARE IDENTIFIED IN THE

DOCUMENTS. KEEP GATES CLEAR AT ALL TIMES EXCEPT FOR

COORDINATED PASSING.

ALL WORK AREAS ARE TO BE THOROUGHLY CLEANED AT THE END OF

EACH DAY.

SEE SPECIFICATION FOR DAILY TOOL INVENTORY REQUIREMENTS. A

STANDARDIZED LIST OF DAILY TOOLS ENTERING AND EXITING IS

PREFERRED. ALL CONSTRUCTION EQUIPMENT MUST BE REMOVED

FROM THE SITE DAILY TO THE DESIGNATED STAGING AREA IN THE

PARKING LOT WITH THE EXCEPTION OF A JOB BOX THAT CAN REMAIN

SECURED ON THE ROOF AREA.

SEE SPECIFICATIONS FOR SITE ACCESS, STORAGE, WASTE REMOVAL,

AND WORK HOURS.

PROTECT GRASS AREAS FROM EQUIPMENT AND LIFTS. SEE DRAWING

FOR PROTECTED UNDERGROUND UTILITY LINES. DAMAGE IS THE

RESPONSIBILITY OF THE CONTRACTOR TO REPAIR.

A

B

C

LEGEND

UTILITY AREA - PRESSURE SENSITIVE

D

E

F

G

H

I

J

GATE

FENCE X-X-X-X-X

1" = 20'-0"1

SITE PLAN

C M

B A

A R

C H

IT

E

C T

S

G R

A N

D A

V E

S P

E N

C E

R , I

A

(P

) 7

.2

.3

REVISIONS

SHEET

D A

T E

P R

O J

E C

T

PL

O

T D

AT

E

FI

LE

P

AT

H

COPYRIGHT. Permission to reproduce all or part of this drawing is hereby granted solely for the limited purpose of construction of this project or archiving. Unauthorized copying, disclosure or construction use without written permission of Cannon Moss Brygger & Associates is prohibited by copyright law.

IF THIS DRAWING IS NOT 30"x42" IT IS NOT TO SCALE

/1

/2

:4

7:

A

M

A u to d e sk

D o c s:

D

A S

D O

C N

C C

F E d u c a ti o n B u ild in g

W in d o w R e p la c e m e n t/ D

D A

S D

O C

N C

C F

W in d o w R e p la c e m e n t C e n tr a l.

rv t

A1.00

R O

C K

W E

L L

C

IT

Y , I

A

.0

D A

S D

O C

N C

C F

E D

U C

A T

IO

N

B U

IL

D

IN

G

W

IN

D O

W R

E P

L A

C E

M E

N T

IO

W

A D

A S

S

IT

E P

L A

N S

N

UP

UP

H EADINTERIO R SILL ANG LE INTERIOR JAM B ANG LE

T ypica l 2 P lacesSILL

UP

UP

DEMO PLAN GENERAL NOTES

KEYNOTES

DEMO WINDOW AND ALL TRIM ITEMS

PATCH AREA AROUND WINDOW - SEE ELEVATION 6/A3.00

WINDOW TO HAVE LEVER HANDLES FOR QUICK EXITING (TILT-AND-

TURN). WINDOW TO SWING INWARD.

REMOVE AND REINSTALL STAIR AS REQUIRED TO INSTALL WINDOW.

DASHED LINES INDICATE DEMOLITION. NOT ALL ITEMS NOTED FOR

CLARITY.

EACH CONTRACTOR TO CAREFULLY EXAMINE EXISTING CONDITIONS

PRIOR TO TIME OF BID.

CONTRACTOR SHALL INFILL, OR PATCH AND REPAIR ANY OPENING IN

EXISTING WALLS AS REQUIRED TO MAINTAIN EXISTING OR NEW RATED

CONSTRUCTION.

PATCH AND REPAIR EXISTING SURFACES, INDICATED TO REMAIN,

DAMAGED DURING DEMOLITION. PREPARE FOR INSTALLATION OF NEW

FINISHES AS SPECIFIED.

PROTECT EXISTING FINISHES TO REMAIN.

FINISHES AND OTHER ITEMS INDICATED FOR DEMOLITION SHALL BE

ADEQUATELY REMOVED TO PROVIDE A SUITABLE SUBSTRATE FOR THE

INSTALLATION OF PROPOSED MATERIALS AND FINISHES.

MAINTAIN WEATHER TIGHT CONDITIONS ON ALL EXISTING SPACES

THROUGHOUT CONSTRUCTION.

OWNER WILL REMOVE ALL WINDOW COVERINGS

OWNER WILL MOVE FURNITURE AND EQUIPMENT TO MAKE WAY FOR

WORK TO BE PERFORMED

COORDINATE PHASING OF DEMOLITION WITH OWNER ROOM BY ROOM

REMOVE AND REPLACE ANY ROTTEN / COMPROMISED SUBSTRATES OR

FRAMING.

OWNER WILL REMOVE WINDOW AC UNITS AND FANS. OWNER WILL

REINSTALL WINDOW AC AND FANS.

A

B

C

D

E

FLOOR PLAN GENERAL NOTES

SEE SHEET T0.01 FOR ALL NOTES AND ABBREVIATIONS

CONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS AND NOTIFY

ARCHITECT OF ANY DISCREPANCIES PRIOR TO BEGINNING THE

AFFECTED WORK.

DO NOT SCALE DRAWINGS, FOLLOW DIMENSIONS.

PATCH AND REPAIR EXISTING WALLS, FLOORS, CEILINGS, ETC., THAT

ARE SHOWN TO REMAIN BUT ARE DAMAGED DUE TO CONSTRUCTION

WORK. THIS SHALL INCLUDE REPAIRING FINISHES DAMAGED BY THE

REMOVAL OR INSTALLATION OF NEW MECHANICAL, ELECTRICAL, OR

FIRE PROTECTION WORK OR DEVICES.

COORDINATE PHASING OF PLACING WINDOWS WITH OWNER ROOM BY

ROOM.

A

B

C

D

E

F

G

H

I

J

A3.00

A3.00

A3.00

A3.00

ED2-21

ED2-26

ED2-12

ED2-18

ED2-17

ED2-16

ED3-11

ED2-19D.1

A A A A

B

J

AAAA

D.1

E

D

A3.00

A3.00

A3.00

A3.00

ED1-13

ED1-12

ED1-17

F I H I

A3.00

A3.00

A3.00

A3.00

A.1A.1ACC

C.1

D.1

D

D D A.1 A.1

D

ED3-24

ED3-19

RD3-20

ED3-18

ED3-15

ED3-14

ED3-12

ED3-30

C

ED1-13

ED1-12 ED1-17

11 1 1 1

ED2-12

ED2-26

ED2-21

ED2-19

ED2-18

ED2-18

ED2-16

ED3-11

ED3-18

RD3-20

ED3-19

ED3-24

ED3-30

ED3-12

ED3-15

ED3-14

1 1 1 1 1 1

1/8" = 1'-0"2

FLOOR 02 - DEMO

1/8" = 1'-0"5 Floor 02

C M

B A

A R

C H

IT

E

C T

S

G R

A N

D A

V E

S P

E N

C E

R , I

A

(P

) 7

.2

.3

REVISIONS

SHEET

D A

T E

P R

O J

E C

T

PL

O

T D

AT

E

FI

LE

P

AT

H

COPYRIGHT. Permission to reproduce all or part of this drawing is hereby granted solely for the limited purpose of construction of this project or archiving. Unauthorized copying, disclosure or construction use without written permission of Cannon Moss Brygger & Associates is prohibited by copyright law.

IF THIS DRAWING IS NOT 30"x42" IT IS NOT TO SCALE

/1

/2

:4

7:

A

M

A u to d e sk

D o c s:

D

A S

D O

C N

C C

F E d u c a ti o n B u ild in g

W in d o w R e p la c e m e n t/ D

D A

S D

O C

N C

C F

W in d o w R e p la c e m e n t C e n tr a l.

rv t

A2.00

R O

C K

W E

L L

C

IT

Y , I

A

.0

D A

S D

O C

N C

C F

E D

U C

A T

IO

N

B U

IL

D

IN

G

W

IN

D O

W R

E P

L A

C E

M E

N T

IO

W

A D

A S

F L

O O

R P

L A

N S

1/8" = 1'-0"6 Floor 01

1/8" = 1'-0"4

FLOOR 3 - RCP

1/8" = 1'-0"3 Floor 01 - DEMO

1/8" = 1'-0"1 Floor 03 - DEMO

N

N

NN

N

N

GENERAL NOTES

KEYNOTES

PREP WINDOW WITHOUT NAILING FLANGE AS NEEDED.

WINDOW TO HAVE LEVER HANDLES FOR QUICK EXITING (TILT-AND-

TURN). WINDOW TO SWING INWARD.

COMPOSITE TRIM

SOLID SURFACE SILL

BISCUIT JOIN AND GLUE JOINTS TOGETHER

MECHANICAL AND ELECTRICAL EQUIPMENT AND COMPONENTS ARE

ILLUSTRATED FOR CONTEXT AND COORDINATION PURPOSES ONLY. SEE

MECHANICAL AND ELECTRICAL DOCUMENTS.

PROVIDE PROPER ANCHORAGE OF ALL WALL-ATTACHED ITEMS

MAINTAINING THE CONTINUITY OF THE COMPLETE AIR/MOISTURE

BARRIER.

ALL EXTERIOR WALL ASSEMBLIES SHALL BE PROPERLY FLASHED AND

SEALED WEATHER-TIGHT .

ENSURE ALL WEEPS, THRU WALL FLASHING AND OTHER DRAINAGE

CAVITIES REMAIN OPEN TO ALLOW CONDENSATION AND MOISTURE TO

ESCAPE. SEALANT SHALL BE APPLIED TO THE UNDERSIDE OF ALL

FLASHING AND DRIPS.

EIFS TRIM TO BE PAINTED TO MATCH THE ADJACENT EXISTING EIFS

COLOR.

EXTERIOR STAIRS TO REMAIN CLEAR AT ALL TIMES FOR EXITING

PURPOSES.

A

B

C

D

E

F

LEGEND

EXISTING WALL MOUNTED AIR CONDITIONER TO REMAIN

REMOVE AND REPLACE DAMAGED WALL PLASTER.

- REPLACE WITH GYPSUM BOARD.

- TEXTURE TO MATCH EXISTING WALL.

- PRIME ONLY, OWNER WILL PAINT

J B

B.1B.1 A.1A.1

A A A A

DD

A.1

A A

A.1

A

A

A

CC

F

DC

L

I H I

K

H

D.1 D.1 E

D.1D

C.1

H

D

G

B

8' - 5 1/2"

A.1 A.1

A.1A.1

ED3-24

V A

R

IE

S V

A R

IE

S

/2

5 1/2" VARIES 5 1/2"

6" VARIES 6"

V A

R

IE

S

C M

B A

A R

C H

IT

E

C T

S

G R

A N

D A

V E

S P

E N

C E

R , I

A

(P

) 7

.2

.3

REVISIONS

SHEET

D A

T E

P R

O J

E C

T

PL

O

T D

AT

E

FI

LE

P

AT

H

COPYRIGHT. Permission to reproduce all or part of this drawing is hereby granted solely for the limited purpose of construction of this project or archiving. Unauthorized copying, disclosure or construction use without written permission of Cannon Moss Brygger & Associates is prohibited by copyright law.

IF THIS DRAWING IS NOT 30"x42" IT IS NOT TO SCALE

/1

/2

:4

7:

A

M

A u to d e sk

D o c s:

D

A S

D O

C N

C C

F E d u c a ti o n B u ild in g

W in d o w R e p la c e m e n t/ D

D A

S D

O C

N C

C F

W in d o w R e p la c e m e n t C e n tr a l.

rv t

A3.00

R O

C K

W E

L L

C

IT

Y , I

A

.0

D A

S D

O C

N C

C F

E D

U C

A T

IO

N

B U

IL

D

IN

G

W

IN

D O

W R

E P

L A

C E

M E

N T

IO

W

A D

A S

E X

T E

R

IO

R E

L E

V A

T

IO

N S

R

C P

1/8" = 1'-0"1 East

1/8" = 1'-0"2 North

1/8" = 1'-0"4 South

1/8" = 1'-0"3 West

1/8" = 1'-0"7

FLOOR 3 - RCP

1/2" = 1'-0"6

TYP. INTERIOR PATCH

1/2" = 1'-0"5

TYP. INTERIOR TRIM

A5.00

A5.00

V

IF

6'

V

IF

3'

VIF.

2' - 6"

A5.00

IG

6"

MIN.

1/4"

V

IF

/4

6"

6"

M

IN

1/

VIF.

7 1/4" 6"

6"

M

IN

1/

VIF.

7 1/4" 6"

A5.00

A5.00

A5.00

V

IF

VIF.

3'-6"

IG

V

IF

3'

V

IF

3'

VIF.

2' - 1"

A5.00

A5.00

A5.00

IG

A5.01

A5.01

A5.01

V

IF

V

IF

2"

VIF.

2'-3" 2"

IP

V

IF

V

IF

VIF.

3' - 1"

A5.00

A5.00

A5.00

IG

1'

/2

8' - 5 1/2"

6"

M

IN

1/

VIF.

7 1/4" 6"

A5.00

A5.00

A5.00

V

IF

6'

V

IF

3'

VIF.

2' - 6"

IG

GENERAL NOTES

ALL EXTERIOR BLOCKING TO BE MOISTURE TREATED (EXTERIOR

ROUGH OPENINGS, AND ANY WOOD IN CONTRACT WITH CONCRETE).

ENSURE ALL WEEPS, THRU WALL FLASHING AND OTHER DRAINAGE

CAVITIES REMAIN OPEN TO ALLOW CONDENSATION AND MOISTURE TO

ESCAPE. SEALANT SHALL BE APPLIED TO THE UNDERSIDE OF ALL

FLASHING AND DRIPS.

FIELD VERIFY EXISTING CONDITIONS IN CONJUNCTION WITH NEW

CONSTRUCTION. NOTIFY ARCHITECT OF DISCREPANCIES.

ALL EXTERIOR WALL TYPES ARE SHOWN IN GRAY FOR REFERENCE

ONLY, VERIFY WALL MAKEUP AND DIMENSIONS IN FIELD.

SHIM WINDOWS WITH EITHER CEDAR WOOD, TREATED WOOD, OR

PLASTIC SHIMS.

FOAM IN PLACE ALL VOIDS AROUND WINDOW TO PROVIDE A

CONTINUOUS INSULATION BARRIER BETWEEN THE WINDOW AND THE

WALL.

ALL BLOCKING TO BE MECHANICALLY FASTENED AND SET IN

ADHESIVE.

VERIFY ALL OPENING SIZES IN FIELD, SIZES MAY VARY. WHEN SIZING

WINDOWS ACCOUNT FOR BLOCKING AND SHIMMING.

ALL WINDOW GRIDS WILL BE BID AS ALTERNATE 1.

A

B

C

D

KEYNOTES

EXISTING WALL

WINDOW AS SCHEDULED - VERIFY ALL SIZES IN FIELD.

BACKER ROD AND SEALANT

BLOCKING AS REQUIRED - TREATED

SOLID SURFACE SILL

SEALANT

COMPOSITE EXTENSION JAMB - VERIFY WALL DEPTH IN FIELD

EIFS SYSTEM

PREFINISHED ALUMINUM FLASHING - COLOR TO MATCH WINDOW

FRAME

FLASHING TAPE

INSULATION 6" X 3"

EXISTING WEATHER BARRIER

WEATHER BARRIER - TO WRAP INTO OPENING

PLASTER FINISH - PATCH BACK AS NEEDED

WINDOW NAILING FLANGE - SET IN SEALANT AND MECHANICALLY

FASTENED

COMPOSITE WINDOW TRIM

SHIM AS REQUIRED

WINDOW HARDWARE

ALUMINUM BREAK METAL WRAP - COLOR TO MATCH WINDOW FRAME

MULLED WINDOW JOINT

MAXIMIZE LOWER WINDOW SIZE - REMOVE UPPER WINDOW IF

POSSIBLE.

E

F

G

H

LEGEND

IP - INSULATED PANEL - PROVIDE TWO PANELS PER WINDOW

RF - INSULATED FIRE RATED GLAZING

IG - INSULATED GLAZING

I

6"

M

IN

1/

VIF.

7 5/8" 6"

6"

MIN.

1/4"

V

IF

/8

6"

6"

M

IN

1/

VIF.

7 5/8" 6"

A5.00

A5.00

A5.01

V

IF

V

IF

/4

VIF.

2'-1"

IG

V

IF

V

IF

2"

VIF.

2'-9" 2"

A5.01

A5.01

A5.01

IP

A5.01

A5.01

A5.01

V

IF

/2

V

IF

2"

VIF.

1'-9" 2"

IP

V

IF

F

IV

VIF.

2'-1"

A5.01

A5.01

A5.01

FR

A5.01

A5.01

A5.01

V

IF

VIF.

3'-6"

FR

V

IF

3'

V

IF

3'

VIF.

2' - 1"

A5.01

A5.01

A5.01

FR

V

IF

V

IF

VIF.

2'-7"

A5.01

A5.01

A5.00

FR

V A

R Y

M A

Y

H E

IG

H

T

M A

X

IM

IZ

E

V

IF

V

IF

A5.01

A5.01

A5.01

FR

FR

V A

R Y

M A

Y

H E

IG

H

T

M A

X

IM

IZ

E

V

IF

V

IF

A5.01

A5.01

A5.01

FR

FR

V A

R Y

M A

Y

H E

IG

H

T

M A

X

IM

IZ

E

V

IF

V

IF

A5.01

A5.01

A5.01

FR

FR

C M

B A

A R

C H

IT

E

C T

S

G R

A N

D A

V E

S P

E N

C E

R , I

A

(P

) 7

.2

.3

REVISIONS

SHEET

D A

T E

P R

O J

E C

T

PL

O

T D

AT

E

FI

LE

P

AT

H

COPYRIGHT. Permission to reproduce all or part of this drawing is hereby granted solely for the limited purpose of construction of this project or archiving. Unauthorized copying, disclosure or construction use without written permission of Cannon Moss Brygger & Associates is prohibited by copyright law.

IF THIS DRAWING IS NOT 30"x42" IT IS NOT TO SCALE

/1

/2

:4

7:

A

M

A u to d e sk

D o c s:

D

A S

D O

C N

C C

F E d u c a ti o n B u ild in g

W in d o w R e p la c e m e n t/ D

D A

S D

O C

N C

C F

W in d o w R e p la c e m e n t C e n tr a l.

rv t

A5.00

R O

C K

W E

L L

C

IT

Y , I

A

.0

D A

S D

O C

N C

C F

E D

U C

A T

IO

N

B U

IL

D

IN

G

W

IN

D O

W R

E P

L A

C E

M E

N T

IO

W

A D

A S

W

IN

D O

W A

N D

D E

T A

IL

S

WINDOWS

WINDOW A

3" = 1'-0"6

JAMB

3" = 1'-0"5

HEAD

3" = 1'-0"7

SILL

WINDOW C WINDOW D

WINDOW IWINDOW F

3" = 1'-0"1

A.1 HEAD

WINDOW A.1

3" = 1'-0"2

HEAD

3" = 1'-0"3

JAMB

3" = 1'-0"4 Detail 3

WINDOW L

WINDOW H

WINDOW K

WINDOW EWINDOW C.1 WINDOW D.1

FIRE RATED FIRE RATED

FIRE RATED FIRE RATED FIRE RATED

WINDOW G

FIRE RATED

WINDOW J

EGRES -FIRE RATED

WINDOW B WINDOW B.1

6"

M

IN

1/

VIF.

7 1/4" 6"

6"

MIN.

1/4"

6"

V

IF

/4

6"

M

IN

1/

7 1/4" 6"

GENERAL NOTES

ALL EXTERIOR BLOCKING TO BE MOISTURE TREATED (EXTERIOR

ROUGH OPENINGS, AND ANY WOOD IN CONTRACT WITH CONCRETE).

ENSURE ALL WEEPS, THRU WALL FLASHING AND OTHER DRAINAGE

CAVITIES REMAIN OPEN TO ALLOW CONDENSATION AND MOISTURE TO

ESCAPE. SEALANT SHALL BE APPLIED TO THE UNDERSIDE OF ALL

FLASHING AND DRIPS.

FIELD VERIFY EXISTING CONDITIONS IN CONJUNCTION WITH NEW

CONSTRUCTION. NOTIFY ARCHITECT OF DISCREPANCIES.

ALL EXTERIOR WALL TYPES ARE SHOWN IN GRAY FOR REFERENCE

ONLY, VERIFY WALL MAKEUP AND DIMENSIONS IN FIELD.

SHIM WINDOWS WITH EITHER CEDAR WOOD, TREATED WOOD, OR

PLASTIC SHIMS.

FOAM IN PLACE ALL VOIDS AROUND WINDOW TO PROVIDE A

CONTINUOUS INSULATION BARRIER BETWEEN THE WINDOW AND THE

WALL.

ALL BLOCKING TO BE MECHANICALLY FASTENED AND SET IN

ADHESIVE.

VERIFY ALL OPENING SIZES IN FIELD, SIZES MAY VARY. WHEN SIZING

WINDOWS ACCOUNT FOR BLOCKING AND SHIMMING.

ALL WINDOW GRIDS WILL BE BID AS ALTERNATE 1.

A

B

C

D

KEYNOTES

EXISTING WALL

WINDOW AS SCHEDULED - VERIFY ALL SIZES IN FIELD.

BACKER ROD AND SEALANT

BLOCKING AS REQUIRED - TREATED

SOLID SURFACE SILL

SEALANT

COMPOSITE EXTENSION JAMB - VERIFY WALL DEPTH IN FIELD

EIFS SYSTEM

PREFINISHED ALUMINUM FLASHING - COLOR TO MATCH WINDOW

FRAME

FLASHING TAPE

INSULATION 6" X 3"

EXISTING WEATHER BARRIER

WEATHER BARRIER - TO WRAP INTO OPENING

PLASTER FINISH - PATCH BACK AS NEEDED

WINDOW NAILING FLANGE - SET IN SEALANT AND MECHANICALLY

FASTENED

COMPOSITE WINDOW TRIM

SHIM AS REQUIRED

WINDOW HARDWARE

ALUMINUM BREAK METAL WRAP - COLOR TO MATCH WINDOW FRAME

MULLED WINDOW JOINT

MAXIMIZE LOWER WINDOW SIZE - REMOVE UPPER WINDOW IF

POSSIBLE.

E

F

G

H

LEGEND

IP - INSULATED PANEL - PROVIDE TWO PANELS PER WINDOW

RF - INSULATED FIRE RATED GLAZING

IG - INSULATED GLAZING

I

6"

MIN.

1/4"

6"

/8

/4

6"

M

IN

1/

VIF.

9 1/8" 2 3/4"

6"

M

IN

1/

9 1/8" 2 3/4"

1'

7/

8' - 5 1/2"

6"

M

IN

1/

9 1/8" 2 3/4"

C M

B A

A R

C H

IT

E

C T

S

G R

A N

D A

V E

S P

E N

C E

R , I

A

(P

) 7

.2

.3

REVISIONS

SHEET

D A

T E

P R

O J

E C

T

PL

O

T D

AT

E

FI

LE

P

AT

H

COPYRIGHT. Permission to reproduce all or part of this drawing is hereby granted solely for the limited purpose of construction of this project or archiving. Unauthorized copying, disclosure or construction use without written permission of Cannon Moss Brygger & Associates is prohibited by copyright law.

IF THIS DRAWING IS NOT 30"x42" IT IS NOT TO SCALE

/1

/2

:4

7:

A

M

A u to d e sk

D o c s:

D

A S

D O

C N

C C

F E d u c a ti o n B u ild in g

W in d o w R e p la c e m e n t/ D

D A

S D

O C

N C

C F

W in d o w R e p la c e m e n t C e n tr a l.

rv t

A5.01

R O

C K

W E

L L

C

IT

Y , I

A

.0

D A

S D

O C

N C

C F

E D

U C

A T

IO

N

B U

IL

D

IN

G

W

IN

D O

W R

E P

L A

C E

M E

N T

IO

W

A D

A S

W

IN

D O

W D

E T

A

IL

S

3" = 1'-0"6

HEAD

3" = 1'-0"7

JAMB

3" = 1'-0"8

SILL

3" = 1'-0"1

WINODW G & H

3" = 1'-0"4

JAMB

3" = 1'-0"5

SILL

3" = 1'-0"3

HEAD

3" = 1'-0"2

HEAD

Sheets
T0.01 - TITLE
A1.00 - SITE PLANS
A2.00 - FLOOR PLANS
A3.00 - EXTERIOR ELEVATIONS & RCP
A5.00 - WINDOW AND DETAILS
A5.01 - WINDOW DETAILS

File details come from the government source that posted it. Updated .