RFB942600-01 - DAS CC IDALS Hoover - Drawings.pdf
PDF 13 MB Posted
- Attached to
- DAS CC IDALS Hoover 5th Floor Renovation
- Solicitation number
- RFB942600-01
- Issued by
- Polk County, Des Moines City, Iowa
About this file
This appears to be a set of architectural drawings file (RFB942600-01) related to a renovation project for the Iowa Department of Administrative Services (DAS) and Iowa Department of Agriculture and Land Stewardship (IDALS) at the Hoover Building's 5th floor. However, there seems to be a discrepancy in the description as it mentions "CDC Warehouse" and "Individual Serving Drink Mix," which does not align with the file name indicating building renovation drawings. Without access to view the actual drawings file contents, I cannot provide specific details about the renovation plans, specifications, or technical requirements that would typically be included in such architectural documentation.
Due to the limited information available and potential inconsistency in the source data, I cannot confidently provide details about pricing, funding, or other specific project parameters that would normally be visible in construction drawings or renovation documentation.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
362S125-30 16" 15'-6"
600S125-30 16" 22'-11"
5/8" TYPE X GYPSUM BOARD
SOUND INSULATION, UNO
PLAN
A3
A6
WALL TYPE
STUD
DESIGNATION
SPACING
MAX. HEIGHT
(5 PSF, L/240)
FIRE RATING /
UL DESIGN
NOTES:
1. REFER TO DETAIL FOR TOP OF WALL BRACING AT ALL WALLS U.N.O.
SOUND
TRANSMISSION
(STC)
METAL STUDS
1/ G1-10
5/8" TYPE 'X' GYP BD
SOUND BATT
INSULATION
3 5/8" METAL STUDS
BATT INSULATION
FOR SOUND
EXTEND 1 STUD ABOVE
CEILING TILE EVERY
4'-0". NOTCH EXISTING
METAL CEILING TILE AS
REQ'D. NOTCH TO BE
CUT TIGHT TO STUD AS
TO NOT BE VISIBLE
WHEN GYPSUM BOARD
IS INSTALLED.
KICKER AT EACH
EXTENDED STUD,
ALTERNATE
DIRECTIONS
BLOCKING AS REQ'D
EXISTING
STRUCTURE ABOVE
EXISTING METAL
CEILING TILE
PROJECT GENERAL NOTES
A. ALL WORK SHALL CONFORM TO THE CONTRACT DOCUMENTS, WHICH INCLUDE,
BUT ARE NOT LIMITED TO, THE OWNER - CONTRACTOR AGREEMENT, THE
PROJECT MANUAL (WHICH INCLUDES GENERAL AND SUPPLEMENTARY
CONDITIONS AND SPECIFICATIONS), DRAWINGS OF ALL DISCIPLINES AND ALL
ADDENDA, MODIFICATIONS AND CLARIFICATIONS ISSUED BY THE ARCHITECT /
ENGINEER.
B. CONTRACT DOCUMENTS SHALL BE ISSUED TO ALL SUBCONTRACTORS BY THE
PRIME CONTRACTOR IN COMPLETE SETS IN ORDER TO ACHIEVE THE FULL
EXTENT AND COMPLETE COORDINATION OF ALL WORK. CONTRACTOR IS
RESPONSIBLE FOR COORDINATING AND CORRELATING QUANTITIES AND
DIMENSIONS.
C. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. NOTIFY
ARCHITECT/ENGINEER OF ANY DISCREPANCIES OR CONDITIONS REQUIRING
INFORMATION OR CLARIFICATION BEFORE PROCEEDING WITH THE WORK.
D. FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS. NOTIFY ARCHITECT /
ENGINEER OF ANY DISCREPANCIES OR CONDITIONS REQUIRING INFORMATION
OR CLARIFICATION BEFORE PROCEEDING WITH THE WORK.
E. DETAILS SHOWN ARE INTENDED TO BE INDICATIVE OF THE PROFILES AND TYPE
OF DETAILING REQUIRED THROUGHOUT THE WORK. DETAILS NOT SHOWN ARE
SIMILAR IN CHARACTER TO DETAILS SHOWN. WHERE SPECIFIC DIMENSIONS,
DETAILS OR DESIGN INTENT CANNOT BE DETERMINED, NOTIFY ARCHITECT /
ENGINEER BEFORE PROCEEDING WITH THE WORK.
F. ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE APPLIED,
INSTALLED, CONNECTED, ERECTED, CLEANED AND CONDITIONED ACCORDING TO
MANUFACTURERS' INSTRUCTIONS. IN CASE OF DISCREPANCIES BETWEEN
MANUFACTURERS' INSTRUCTIONS AND THE CONTRACT DOCUMENTS, NOTIFY
ARCHITECT / ENGINEER BEFORE PROCEEDING WITH THE WORK.
G. LARGE-SCALE, MORE SPECIFIC DETAILS TAKE PRECEDENCE OVER
SMALLER-SCALE, LESS SPECIFIC DETAILS AND INFORMATION. MORE STRINGENT
REQUIREMENTS FOR CODE, PRODUCTS AND INSTALLATION TAKE PRECEDENCE
OVER LESS STRINGENT REQUIREMENTS. NOTIFY ARCHITECT/ENGINEER OF ANY
DISCREPANCIES OR CONDITIONS REQUIRING INFORMATION OR CLARIFICATION
BEFORE PROCEEDING WITH THE WORK.
H. PROVIDE CONTINUOUS SEALANT AROUND ALL MATERIALS AT ALL INTERIOR AND
EXTERIOR WALL PENETRATIONS. REFER TO SPECIFICATIONS FOR APPROPRIATE
SEALANT.
I. ALL DISSIMILAR METALS SHALL BE EFFECTIVELY ISOLATED FROM EACH OTHER
TO AVOID GALVANIC CORROSION.
J. SEAL ALL OPENINGS IN WALLS, FLOORS, CEILINGS, AND ROOFS, AROUND DUCTS,
PIPES, VENTS, TRAPS, CONDUIT AND ALL OTHER PENETRATIONS WITH FIRE
STOPPING AS SPECIFIED AND REQUIRED BY CODES. IF FIRE STOPPING IS NOT
REQUIRED AT PENETRATIONS PER CODE, SEAL WITH CONTINUOUS SEALANT.
K. PROVIDE TEMPORARY WALLS, ENCLOSURES, DUST SHIELDS AND WALK-OFF MATS
AS REQUIRED TO SEPARATE DEMOLITION AND CONSTRUCTION FROM EXISTING
BUILDING.
L. PROVIDE BRACING AND SHORING AS REQUIRED TO PROTECT EXISTING
STRUCTURE TO REMAIN. PROVIDE SECURE AND WEATHERPROOF ENCLOSURE OF
TEMPORARY OPENINGS IN EXTERIOR WALLS. PROTECT ALL BUILDING
COMPONENTS FROM DAMAGE DURING DEMOLITION AND CONSTRUCTION.
M. RESTORE ALL EXISTING AREAS AFFECTED BY DEMOLITION AND RELATED NEW
CONSTRUCTION TO THEIR ORIGINAL CONDITION, INCLUDING BUT NOT LIMITED TO
WALLS, FLOORS, AND CEILINGS AND THEIR ASSOCIATED FINISHES.
N. PROVIDE SOLID WALL BACKING WITH METAL OR FIRE-RETARDANT WOOD
BLOCKING BEHIND DOOR HARDWARE SUCH AS WALL STOPS, BUMPERS, HOLD
OPENS, ETC. AND AT ALL ITEMS REQUIRING FASTENING THROUGH GYP BD. TO
BLOCKING
O. RENDERED IMAGES MAY NOT BE AN ACCURATE REPRESENTATION OF BUILDING
CONDITIONS, REFER TO PLANS AND DETAILS CONTAINED WITHIN FOR SCOPE OF
WORK.
SHEET INDEX
SHEET # SHEET TITLE
GENERAL
G1-10 TITLE SHEET, SHEET INDEX, PROJECT GENERAL NOTES
G1-21 CODE DATA AND CODE DATA PLAN
ARCHITECTURAL
A1-11 LEVEL 5 DEMOLITION PLAN
A1-21 LEVEL 5 FLOOR PLAN
A1-31 LEVEL 5 REFLECTED CEILING PLAN AND DETAILS
A1-41 LEVEL 5 FINISH PLAN & SCHEDULE
PLUMBING
MP0-01 DIV 21,22,23 SYMBOLS / ABBREVIATIONS
P1-11 FIFTH FLOOR PLUMBING DEMOLITION PLAN
P2-10 FOURTH FLOOR PLUMBING PLAN
P2-11 FIFTH FLOOR PLUMBING PLAN
P6-11 PLUMBING ISOMETRICS, DETAILS, SCHEDULES, AND SPECIFICATIONS
FIRE PROTECTION
FP2-11 FIFTH FLOOR FIRE PROTECTION PLAN
MECHANICAL
M1-11 FIFTH FLOOR MECHANICAL DEMOLITION PLAN
M2-11 FIFTH FLOOR MECHANICAL PLAN
M4-11 MECHANICAL DETAILS
M5-11 MECHANICAL SCHEDULES AND SPECIFICATIONS
ELECTRICAL
E1-11 LEVEL 5 ELECTRICAL DEMOLITION PLAN
E2-11 LEVEL 5 POWER AND FIRE ALARM PLAN
E2-12 LEVEL 5 POWER DEVICE DIMENSIONS
E2-21 LEVEL 5 LIGHTING PLAN
E4-10 ELECTRICAL SYMBOLS, SCHEDULES, AND DETAILS
TECHNOLOGY
T2-11 FIFTH FLOOR TECHNOLOGY PLAN
T2-21 LEVEL 5 SOUND MASKING FLOOR PLAN
T3-11 TECHNOLOGY ENLARGEMENTS AND DETAILS
T6-11 TECHNOLOGY DETAILS, RISERS, AND MATERIAL SCHEDULES
217 EAST 2ND STREET
SUITE 110
DES MOINES, IOWA 50309
PHONE: 515.243.9143
DES MOINES OFFICE
/2
/4
R E
F E
R E
N C
E S
C A
L E
SHEET
PROJECT
PROJECT NO.
FILE NAME
DRAWN BY
DESIGNED BY
ORIGINAL ISSUE DATE
CLIENT PROJECT NO.
TITLE
REVIEWED BY
PROJECT INDEX:
OWNER: PROJECT ADDRESS:
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
WITHOUT PRIOR WRITTEN CONSENT.
© 2024 I & S GROUP, INC.
MANAGING OFFICE:
1/21/2025 3:21:56 PM
G1-10
TITLE SHEET,
SHEET INDEX,
PROJECT
GENERAL NOTES
DAS CC IDALS
HOOVER
DES MOINES IOWA
KKT
KKT
01/21/2025
EMS
9426.00
24-31954
5TH FLOOR
RENOVATION
HOOVER STATE OFFICE BUILDING
1305 EAST WALNUT STREET
DES MOINES, IOWA 50319
PROJECT MANAGER: PYLAR EATON
EMAIL: PYLAR.EATON@ISGINC.COM
IOWA DEPT OF ADMINISTRATIVE
SERVICES
MICHAEL BRADBURY
1305 EAST WALNUT STREET
DES MOINES, IOWA 50319
PHONE #
FAX #
DES MOINES, IOWA
G1-10 TITLE SHEET, SHEET INDEX, PROJECT GENERAL NOTES
DAS CC IDALS HOOVER 5TH FLOOR RENOVATION
200 31954 G1-10
ISG PROJECT # 24-31954
3" = 1'-0"A
WALL TYPE A (METAL STUD PARTITION)
1/2" = 1'-0"1
TYPICAL WALL CONNECTION TO
EXISTING STRUCTURE
VICINITY MAP
DAS PROJECT #9426.00 RFP: 942600-01
CONTRACTOR
PARKING
BID ALTERNATES:
BID ALTERNATE #1
• BASE BID: NO SOUND MASKING IN WORK AREA.
• BID ALTERNATE: INSTALL SOUND MASKING IN WORK AREA.
BID ALTERNATE #2
• BASE BID: REUSE EXISTING THERMOSTATS.
• BID ALTERNATE: REPLACE THERMOSTATS AS IDENTIFIED IN DRAWINGS.
REFER TO ASSOCIATED PLANS FOR MORE INFORMATION ON EACH ALTERNATE.
PRINTED SIGNATURE
SIGNATURE DATE
LICENSE RENEWAL DATELICENSE NUMBER
SEAL
S N
E C I
W
E
LANOISSEFORP
L D
IO A
N R
E E
NI
G
E
I HEREBY CERTIFY THAT THE PORTION OF THIS
TECHNICAL SUBMISSION DESCRIBED BELOW WAS
PREPARED BY ME OR UNDER MY DIRECT SUPERVISION
AND RESPONSIBLE CHARGE. I AM A DULY LICENSED
ENGINEER UNDER THE LAWS OF THE STATE OF IOWA.
SHEETS COVERED BY THIS SEAL:
BRETT
WALKER
P28162 12/31/2026P28162
BRETT WALKER
01/21/2025
I HEREBY CERTIFY THAT THE PORTION OF THIS
TECHNICAL SUBMISSION DESCRIBED BELOW WAS
PREPARED BY ME OR UNDER MY DIRECT SUPERVISION
AND RESPONSIBLE CHARGE. I AM A DULY LICENSED
ARCHITECT UNDER THE LAWS OF THE STATE OF IOWA.
PRINTED SIGNATURE
SIGNATURE DATE
LICENSE RENEWAL DATELICENSE NUMBER
SEAL
S N
E C I
W
R T
E
C E
TI
H
C A
LANOISSEFORP
L D
IO A SHEETS COVERED BY THIS SEAL:
ERICA
SCHAEFER
07376 06/30/202607376
ERICA M. SCHAEFER
01/21/2025
PRINTED SIGNATURE
SIGNATURE DATE
LICENSE RENEWAL DATELICENSE NUMBER
SEAL
S N
E C I
W
E
LANOISSEFORP
L D
IO A
N R
E E
NI
G
E
I HEREBY CERTIFY THAT THE PORTION OF THIS
TECHNICAL SUBMISSION DESCRIBED BELOW WAS
PREPARED BY ME OR UNDER MY DIRECT SUPERVISION
AND RESPONSIBLE CHARGE. I AM A DULY LICENSED
ENGINEER UNDER THE LAWS OF THE STATE OF IOWA.
SHEETS COVERED BY THIS SEAL:
ADAM
PULS
P23206 12/31/2025P23206
ADAM W. PULS
01/21/2025
PRINTED SIGNATURE
SIGNATURE DATE
LICENSE RENEWAL DATELICENSE NUMBER
SEAL
S N
E C I
W
E
LANOISSEFORP
L D
IO A
N R
E E
NI
G
E
I HEREBY CERTIFY THAT THE PORTION OF THIS
TECHNICAL SUBMISSION DESCRIBED BELOW WAS
PREPARED BY ME OR UNDER MY DIRECT SUPERVISION
AND RESPONSIBLE CHARGE. I AM A DULY LICENSED
ENGINEER UNDER THE LAWS OF THE STATE OF IOWA.
SHEETS COVERED BY THIS SEAL:
ROYAL
STREED
P26593 12/31/2026P26593
ROYAL D. STREED
01/21/2025
G1-10
G1-21
A1-11
A1-21
A1-31
A1-41
A1-31
MP0-01 P1-11
P2-10
P2-11
P6-11
FP2-11
E1-11
E2-11
E2-12
E2-21
E4-10 T2-11
T2-21
T3-11
T6-11
REVISION SCHEDULE
DATE DESCRIPTION BY
M1-11
M2-11
M4-11
M5-11
CODE DATA PLAN KEY
EXIT
FIRE EXTINGUISHER
SEMI-RECESSED FIRE
EXTINGUISHER CABINET
FE
FEC
FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE
BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL
REQUIRED TO HAVE PROTECTED OPENINGS OR
PENETRATIONS SHALL BE EFFECTIVELY AND PERMANENTLY
IDENTIFIED WITH SIGNS OR STENCILING. SUCH
IDENTIFICATION SHALL:
1. BE LOCATED IN ACCESSIBLE CONCEALED FLOOR, FLOOR-
CEILING OR ATTIC SPACES
2. BE LOCATED WITHIN 15 FEET OF THE END OF EACH WALL
AND AT INTERVALS NOT EXCEEDING 30 FEET MEASURED
HORIZONTALLY ALONG THE WALL OR PARTITION, AND
3. INCLUDE LETTERING NOT LESS THAN 3 INCHES IN HEIGHT
WITH A MINIMUM 3/8" STROKE IN A CONTRASTING COLOR
INCORPORATING THE SUGGESTED WORDING "FIRE
AND/OR SMOKE BARRIER - PROTECT ALL OPENINGS" OR
OTHER SIMILAR WORDING.
COMMON PATH OF TRAVEL
WALL LEGEND
EXISTING CONSTRUCTION TO REMAIN
NEW CONSTRUCTION
CONTRACTOR TO VERIFY EXISTING RATED WALL
CONSTRUCTION IN FIELD AND REPORT ANY
DISCREPANCIES TO THE PROJECT ARCHITECT.
H521
STORAGE H519
STAIR
H520
ELECH522
COMM
H532
ELEC
H534
COMM
H515
WOMENS
H553
STORAGE
H509
ELEV
H511
ELEV
H503
ELEV
H505
ELEV
H507
STAIR
H563
MENS
H594
COMM
H592
ELEC
H575
FREIGHT
ELEV
H571
EQUIP
H569
STORAGE
H567
STAIR
H577
VENDING
H588
STORAGE
H572
COMM
H570
ELEC
H523
CORR
OPEN TO BELOW
H579
BREAK
ROOM
H501
ELEV
LOBBY
H513
CORRIDOR
H540
OFFICE
COS
H542
OFFICE
SEC
H544
RR
H546
CONFERENCE
H548
OFFICE
D. SEC
H550
OFFICE
REG
H552
OFFICE
REG
H554
OFFICE
CFO
H568
OFFICE
STATE VET
H574
OFFICE
ASST VET
H576
OFFICE
ASST VET
H578
OFFICE
CLIMATE
H584
OFFICE
HR
H586
CONFIDENTIAL
ROOM
H560
CONFERENCE
H562
CONFERENCE
H558
OFFICE
LEGAL
H524
COLLABORATION
H518
CONFERENCE
H516
LARGE
CONFERENCE
H512
OFFICE
S / W
H514
OFFICE
S / W
H590
OPEN
OFFICE
H561
CORRIDOR
H564
OPEN
OFFICE
H538
OPEN
OFFICE
H516B
H516A
H518
H512
H514
H
H
H
H
H
H
H544
H
H
H A
H A
H
H569
H568
H574
H576
H578
H584
H586
H545
KITCHENETTE
H573
JANITOR
H 2H545
NOT IN SCOPE
NOT IN SCOPE
NOTE: FURNITURE SHOWN FOR REFERENCE
ONLY. OWNER TO PROVIDE FURNITURE.
FE - NEW
FE - NEW
H510
OPEN
OFFICE
THIS SPACE TO BE OCCUPIED AT A
LATER DATE BY ANOTHER TENANT.
ARCHITECTURAL SCOPE OF THIS
SPACE IS UPDATING FINISHES.
SEE DEMOLITION PLAN FOR
LIMITED DEMO IN THIS AREA.
TWO EXITS REQUIRED FROM H510,
SPACED OVER 1/3 DIAGONAL OF ROOM
104'-4 " D
IA
GONAL
1/3 D
IA
GONAL =
4'-9 1/2
FEC
FE
FEC
FEC
FE
FE
FEC
41' - 0"
COMMON PATH: 69' < 75'
H510A
R1A
R1A
R1A
V E
R
IF
Y W
O
W N
E R
P L
A N
S
V E
R
IF
Y W
O
W N
E R
P L
A N
S
V E
R
IF
Y W
O
W N
E R
P L
A N
S
MOUNTING HEIGHTS AND STANDARDS
WALL-MOUNT LAVATORY
(WITH KNEE AND TOE
CLEARANCES)
DROP-IN LAVATORY (WITH
KNEE AND TOE
CLEARANCES)
MIN
8"
M
IN9
*K C
H
MAX
6" MIN
11"
KNEE
CLEARANCE
AREA
TOE
CLEARANCE
AREA
25" MAX
17" MIN
*T S
H
*T S
H
MIN
8"
M
IN9
*K C
H
MAX.
6" MIN
11"
25" MAX
17" MIN
KNEE
CLEARANCE
AREA
TOE
CLEARANCE
AREA
18 1/4" MIN.
W H
IC
H
E V
E R
I S
G
R E
A T
E R
WATER CLOSET
REAR WALL
WATER CLOSET
SIDE WALL
24" MIN 12" MIN
*WCC
*G B
H
24" MIN
42" MAX
7"-9"
M
IN
/2
M
IN
*G B
H
*V B
H
M
IN
12" MAX 42" MIN
*VBC
54" MIN
OPERABLE PARTS OF
DISPENSERS AND SANITARY
PRODUCT RECEPTACLES
SHALL BE LOCATED WITHIN
HATCHED AREA (ONLY
APPLICABLE FOR ADULT
RESTROOMS)
60" CLEAR FLOOR SPACE
*W C
S 4
M A
X
*T P
H
MIRROR
24" MIN
M
IN
S U
R F
A C
E O
F M
IR
R
O R
M
A X
T O
R E
F L E
C T
IV
E
NOTE:
35" IF NOT LOCATED
ABOVE LAVS, SINKS
OR COUNTERS
CENTER ON
LAV BELOW
SOAP
DISPENSER
PAPER
TOWEL
DISPENSER
O P
E R
A B
L E
P A
R T
T
O H
IG
H
E S
T
FIRE EXTINGUISHER
OR CABINET
T O
T O
P O
F H
A N
D L
E
OR
FIXTURE CLEARANCES
DESCRIPTION
*GBH GRAB BAR HEIGHT
*TPH TOILET TISSUE DISPENSER HEIGHT
*WCC WATER CLOSET CENTER LINE
*WCS WATER CLOSET SEAT HEIGHT
*TSH TOP OF SINK OR COUNTER HEIGHT
*KCH KNEE CLEARANCE HEIGHT
*VBH VERTICAL GRAB BAR HEIGHT
*VBC VERTICAL GRAB BAR CENTERLINE
*HDH HIGH DRINKING FOUNTAIN SPOUT HEIGHT
*LDH LOW DRINKING FOUNTAIN SPOUT HEIGHT
*DSD DRINKING FOUNTAIN SPOUT DEPTH
FIXTURE GROUPS
*URH URINAL RIM HEIGHT
ADULTS (>12 YR)
33" - 36"
18" - 48"
17" - 18"
17" - 19"
34"
27"
39" - 41"
39" - 41"
38" - 43"
36"
5"
R1
ACCESSIBLE
NA
18" - 48"
16" - 18"
17" - 19"
34"
27"
NA
NA
38" - 43"
36"
5"
STANDARD
S
17" 24"
GRAB BARS NIC. PROVIDE
BLOCKING FOR FUTURE
GRAB BARS. TYPICAL.
A
M
IN
MATERIALS KEY
WOOD
SAND
STEEL
GRAVEL
GYPSUM BOARD
PLYWOOD
CONCRETE (SECTION)
GRANULAR FILL
EARTH
CMU (SECTION)
BATT INSULATION
BRICK
RIGID INSULATION
OR SHEATHING
SYNTHETIC STUCCO
TAGS AND SYMBOLS
SECTION
INTERIOR /
EXTERIOR
ELEVATION
DETAIL CALLOUT
AREA OF DETAIL
LEVEL 1
100'-0"
ELEVATION
WINDOW TYPE
DRAWING
TITLE
SHEET NUMBER
DETAIL NUMBER
ABBREVIATIONS
SPRAY IN PLACE
INSULATION
MATERIAL TYPE
FLOOR
MATERIAL TYPE
CASEWORK
TAG
VIEW NAME
1/8" = 1'-0"
FIN#
F FIN#
AL15
CDS
W#
H# D#
MOD LINE 1
MOD LINE 2
CDS CATALOG NUMBER FROM
NORTH AMERICAN
ARCHITECTURAL WOODWORK
STANDARDS (NAAWS)
(IF "M" IS INCLUDED SEE NOTE
BELOW FOR DESCRIPTION OF
MODIFICATION)
NOMINAL DEPTH
NOMINAL HEIGHT
NOMINAL WIDTH
DESCRIPTION OF MODIFICATION
FROM CDS CATALOG
A1-11
A1-11
SECTION NUMBER
SHEET NUMBER
A1-11
ELEVATION NUMBER
SHEET NUMBER
DENOTES
ANNOTATION IS
REFERENCING
ANOTHER VIEW
NEW
CONSTRUCTION
GRIDS
EXISTING
CONSTRUCTION
GRIDS
WALL TYPE M12
KEYNOTE TAG 3
DOOR NUMBERS 101
1 1
B
A
N
/2
/4
R E
F E
R E
N C
E S
C A
L E
SHEET
PROJECT
PROJECT NO.
FILE NAME
DRAWN BY
DESIGNED BY
ORIGINAL ISSUE DATE
CLIENT PROJECT NO.
TITLE
REVIEWED BY
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
WITHOUT PRIOR WRITTEN CONSENT.
© 2024 I & S GROUP, INC.
1/21/2025 3:22:01 PM
G1-21
CODE DATA AND
CODE DATA PLAN
DAS CC IDALS
HOOVER
DES MOINES IOWA
KKT
KKT
01/21/2025
EMS
9426.00
24-31954
5TH FLOOR
RENOVATION
G1-21 CODE DATA AND CODE DATA PLAN
200 31954 G1-21
SHEET NOT VALID UNLESS THIS TEXT IS COLOR.
GENERAL CODE DATA
PROJECT DESCRIPTION:
INTERIOR RENOVATION OF EXISTING OFFICE SPACE ON FIFTH
FLOOR OF HOOVER BUILDING AT IOWA CAPITOL COMPLEX.
(GRAY SHADED AREAS ON PLAN ARE NOT IN ARCHITECTURAL
SCOPE.)
APPLICABLE CODES:
2015 INTERNATIONAL EXISTING BUILDING CODE
OCCUPANCY:
B-BUSINESS
CONSTRUCTION TYPE:
UNKNOWN
EXISTING BUILDING (1975) IS SPRINKLED 5 STORIES ABOVE
GRADE, CONCRETE PRIMARY STRUCTURAL ELEMENTS
FIRE PROTECTION SYSTEMS:
MODIFICATION OF EXISTING SPRINKLER SYSTEM
PROJECT SCOPE:
TOTAL AREA IN SCOPE: 30,106 SF
PLUMBING FIXTURES:
EXISTING TO REMAIN, NO CHANGE IN OCCUPANCY OR SPACE
USE
NOTE: ONE RESTROOM ADDED OFF PRIVATE OFFICE H542,
COMPLIES WITH IBC 1109.2 AND ICC A117.1 - 603.
FIRE SUPPRESSION NOTES
THROUGHOUT AREA OF WORK, MODIFY EXISTING AND / OR
PROVIDE A NEW NFPA 13 FIRE SUPPRESSION (SPRINKLER)
SYSTEM. THE LICENSED AUTOMATIC SPRINKLER SYSTEM
DESIGNER / INSTALLER SHALL FIELD VERIFY ALL CONDITIONS
PRIOR TO BID. THE NFPA 13 SPRINKLER SYSTEM SHALL BE
DESIGNED, INSTALLED, MODIFIED AND TESTED BY A LICENSED
AUTOMATIC SPRINKLER SYSTEM DESIGNER / INSTALLER AND
SHALL MEET ALL APPLICABLE CODE REQUIREMENTS. THE
LICENSED AUTOMATIC SPRINKLER SYSTEM DESIGNER SHALL
PROVIDE AUTOMATIC SPRINKLER SYSTEM DESIGN
DOCUMENTS AND SHALL SUBMIT THEM TO ALL APPLICABLE
JURISDICTIONS AND AUTHORITIES AND SHALL PROCURE ALL
NECESSARY PERMITS. SPRINKLER DESIGNER / INSTALLER
SHALL PAY ALL NECESSARY PERMITTING FEES.
DESIGN OF NEW / MODIFIED NFPA 13 SPRINKLER SYSTEM
SHALL BE BASED ON, BUT NOT LIMITED TO THE FOLLOWING
CRITERIA:
1. COMPLY WITH NFPA 13 AND ALL OTHER APPLICABLE
CODES.
2. MODIFY EXISTING SPRINKLER HEAD LAYOUT TO PROVIDE
ADEQUATE COVERAGE PER CODE REQUIREMENTS.
3. MODIFY EXISTING SPRINKLER HEAD AND PIPING LAYOUT
INCLUDING ALL DROPS, ARM-OVERS AND MAIN PIPES TO
AVOID RELOCATED DIFFUSERS, LIGHT FIXTURES,
MECHANICAL WORK, PLUMBING WORK, ELECTRICAL WORK,
DEMOLITION WORK, NEW CONSTRUCTION WORK AND ALL
OTHER WORK AND COMPONENTS IN THE CONTRACT.
4. COMPLETE ALL TEMPORARY AND PERMANENT WORK
NECESSARY FOR THE REMOVAL AND REPLACEMENT OF
CEILING GRIDS, INCLUDING NEW CEILING GRIDS AND GRIDS
REMOVED AND REPLACED ONLY TO COMPLETE OTHER
WORK.
5. PROVIDE PROPER COVERAGE IN CONCEALED SPACES AS
REQUIRED PER CODE.
6. WHERE INSTALLING NEW WORK ADJACENT TO EXISTING,
MATCH NEW COMPONENTS TO EXISTING COMPONENTS
WITHIN CODE LIMITATIONS.
7. ALL NEW AND RELOCATED SPRINKLER PIPING AND
COMPONENTS SHALL BE CONCEALED ABOVE CEILINGS AND
WITHIN WALLS.
8. ALL SPRINKLER HEADS TO BE INSTALLED IN ACOUSTICAL
CEILING TILE SHALL BE INSTALLED IN CENTER OF TILE.
(MODIFIED OR ADDITION TO EXISTING SPRINKLER SYSTEM)
3/32" = 1'-0"1
LEVEL 5 CODE DATA FLOOR PLAN
# POUND OR NUMBER
@ AT
ACP ACOUSTICAL CEILING PANEL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH DISABILITIES ACT
ADD ADDENDUM
ADDL ADDITIONAL
ADJ ADJACENT
AFF ABOVE FINISH FLOOR
AFG ABOVE FINISHED GRADE
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
APPROX APPROXIMATELY
ARCH ARCHITECTURAL
AWP ACOUSTICAL WALL PANEL
B BASE
BD BOARD
BL BROADLOOM CARPET
BLDG BUILDING
BO BOTTOM OF OR BY OWNER
BR BRICK
BRG BEARING
BSMT BASEMENT
C CONDUIT
CFS COLD FORMED STEEL
CG CORNER GUARD
CIP CAST IN PLACE
CJ CONTROL JOINT OR CONSTRUCTION JOINT
CL CENTERLINE
CLG CEILING
CLR CLEAR
CM CORRUGATED METAL
CMU CONCRETE MASONRY UNIT
CO CLEANOUT
CONC CONCRETE
CONF CONFERENCE
CONT CONTINUOUS
CPT CARPET
CR CHAIR RAIL
CRK CORK
CT TILE
CURT PRIVACY CURTAIN
CY CUBIC YARD
DEMO DEMOLITION
DF DRINKING FOUNTAIN
DH DOOR HOLDER (MAGNETIC)
DIA DIAMETER
DLS DIMENSIONAL LETTER SIGNAGE
EA EACH
EC ELECTRICAL CONTRACTOR
EF EXHAUST FAN
EIFS EXTERIOR INSULATION FINISH SYSTEM
ELEC ELECTRICAL
ELEV ELEVATION
EMERG EMERGENCY
ENCL ENCLOSURE
EPDM ETHYLENE PROPYLENE DIENE MONOMER
EPX EPOXY
EQ EQUAL
EQUIP EQUIPMENT
ETC ETCETERA
EWC ELECTRIC WATER COOLER
EWC ELECTRIC WATER COOLER
EX EXISTING
EXP EXPANSION, EXPOSED
EXT EXTERIOR
F&I FURNISH AND INSTALL
FA FRESH AIR
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FBO FURNISHED BY OTHERS
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FLOOR FINISH
FFE FINISHED FLOOR ELEVATION
FRP FIBERGLASS REINFORCED PLASTIC
FRZ FREEZER
FS FLOOR SINK
FT FOOT OR FEET
FTG FOOTING
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERATOR
GFCI GROUND FAULT CIRCUIT INTERRUPT
GL GLAZING
GND GROUND
GYP GYPSUM
HD HUB DRAIN
HDG HOT DIP GALVANIZED
HDW HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HSS HOLLOW STRUCTURAL SECTION
HT HEIGHT
HVAC HEATING VENTILATION AND AIR CONDITIONING
ID INSIDE DIAMETER
IG ISOLATED GROUND
IMP INSULATED METAL PANEL
INFO INFORMATION
INP IN-PLACE
INSUL INSULATION
INT INTERIOR
J JUNCTION BOX
JAN JANITOR
JBE JOIST BEARING ELEVATION
JST JOIST
KES KITCHEN EQUIPMENT SUPPLIER
kW KILOWATT
LAV LAVATORY
LB POUND
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LN LINEAR
LVT LUXURY VINYL TILE
MATL MATERIAL
MAX MAXIMUM
MB MARKER BOARD
MECH MECHANICAL
MEP MECHANICAL , ELECTRICAL, PLUMBING
MEZZ MEZZANINE
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTD MOUNTED
MTL METAL
MULL MULLION
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OC ON CENTER
OCEW ON CENTER EACH WAY
OD OUTSIDE DIAMETER
OH OVERHEAD
OHD OVERHEAD DOOR
OL OVERALL LENGTH
OPNG OPENING
ORD OVERFLOW ROOF DRAIN
OSB ORIENTED STRAND BOARD
PC PHOTO CELL, POLISHED CONCRETE
PLAM PLASTIC LAMINATE
PLWP PLASTIC LAMINATE WALL PANEL
PNT PAINT
PNT-#E EPOXY PAINT
POLYETH POLYETHYLENE
POLYISO POLYISOCYANURATE
PRV POWER ROOF VENTILATOR
PVC POLYVINYL CHLORIDE
QT QUARRY TILE
QTZ QUARTZ
RA RETURN AIR
RB RESILIENT BASE
RBR RUBBER
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REF REFRIGERATOR
REINF REINFORCED
REQD REQUIRED
RES RESINOUS FLOOR
REV REVISION / REVISED
RM ROOM
RO ROUGH OPENING
ROW / R/W RIGHT OF WAY
RP RESIN PANEL
RTE REFER TO ELEVATION
RTU ROOF TOP UNIT
SA SUPPLY AIR
SC SEALED CONCRETE
SF SQUARE FOOT
SIM SIMILAR
SM SURFACE MOUNTED
SPEC SPECIFICATION
SS SOLID SURFACE
SSTL STAINLESS STEEL
STD STANDARD
STN STONE
STOR STORAGE
SUSP SUSPENDED
SV SHEET VINYL
SY SQUARE YARDS
T&G TONGUE AND GROOVE
T&P TEMPERATURE AND PRESSURE
TB TACK BOARD
TBD TO BE DETERMINED
TD TRENCH DRAIN
TEC TECTUM
TEL TELEPHONE
TEMP TEMPERATURE
TER TERRAZZO
TO TOP OF
TOF TOP OF FOOTING
TOL TOP OF LEDGE
TOS TOP OF STEEL
TOW TOP OF WALL
TR TAMPER RESISTANT
TS TUBE STEEL / THRESHOLD / TRANSITION STRIP
TV TELEVISION
TYP TYPICAL
UG UNDERGROUND
UH UNIT HEATER
UNO UNLESS NOTED OTHERWISE
VCT VINYL COMPOSITE TILE
VERT VERTICAL
VEST VESTIBULE
VF VINYL FLOOR
VIF VERIFY IN FIELD
VTR VENT THROUGH ROOF
VWP VENEER WALL PANEL
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WCG WALL COVERING
WD WOOD
WF WINDOW FILM
WG WALL GUARD
WH WALL HYDRANT
WHTR WATER HEATER
WP WEATHERPROOF
WT WINDOW TREATMENT
WWF WELDED WIRE FABRIC
XFMR TRANSFORMER
REVISION SCHEDULE
DATE DESCRIPTION BY
F
WALL LEGEND
EXISTING CONSTRUCTION TO REMAIN
DEMOLITION
DEMOLITION SHEET NOTES
A. EXISTING CONDITIONS SHOWN ON DRAWINGS REPRESENT
CURRENT BUILDING. IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO EXAMINE THE DRAWINGS AND FIELD
VERIFY EXISTING CONDITIONS TO DETERMINE SCOPE OF
DEMOLITION WORK REQUIRED TO COMPLETE THE
REMODELING WORK INDICATED ON THE DRAWINGS PRIOR
TO PERFORMING WORK. ADDITIONAL WORK THAT IS
REQUIRED, WAS VISIBLE, AND COULD HAVE BEEN IDENTIFIED
DURING BIDDING SHALL BE COMPLETED BY THE
RESPONSIBLE TRADE CONTRACTOR(S) AT NO ADDITIONAL
COST TO THE OWNER.
B. REPORT ANY DISCREPANCIES TO THE ARCHITECT FOR
REVIEW. WORK DONE WITHOUT RESOLUTION OF
DISCREPANCIES MUST BE REDONE AT THE REQUEST OF THE
ARCHITECT AT NO ADDITIONAL COST TO THE CONTRACT.
C. DEMOLITION OF ANY EXISTING CONSTRUCTION SHALL
INCLUDE WHAT IS NECESSARY AND REQUIRED TO
ACCOMMODATE THE REQUIREMENTS OF NEW
CONSTRUCTION.
D. ALL LOOSE FURNISHINGS (CHAIRS, TABLES, DESKS, ETC.)
SHALL BE REMOVED AND RE-INSTALLED BY THE OWNER
UNLESS NOTED OTHERWISE.
E. ALL CORING THRU EXISTING FLOORS, WALLS & CEILINGS
SHALL BE PERFORMED BY THE CONTRACTOR REQUIRING
THE SAME.
F. ALL ROOF PENETRATIONS SHALL BE PERFORMED BY THE
TRADE REQUIRING THE SAME. PATCHING & FLASHING ROOF
SHALL BE PERFORMED BY THE ROOFING CONTRACTOR.
G. VERIFY WITH OWNER FOR ITEMS TO BE SALVAGED BEFORE
STARTING DEMOLITION WORK.
H. COORDINATE DEMOLITION OF LOAD BEARING WALLS &
STRUCTURAL ELEMENTS WITH STRUCTURAL PLANS.
I. CONSTRUCT DUST PROOF PARTITIONS TO SEPARATE AREAS
OF CONSTRUCTION FROM ADJACENT OCCUPIED AREAS
OUTSIDE SCOPE OF CONSTRUCTION.
J. AT OPENINGS IN EXISTING MASONRY WALLS, REMOVE
EXISTING WALL TO NEAREST MASONRY JOINT. SEE FLOOR
PLAN FOR OPENING SIZES. SAWTOOTH INTO EXISTING JAMB.
MATCH ADJACENT FINISHES, UNLESS NOTED OTHERWISE.
K. REQUIRED MEANS OF EGRESS FROM THE BUILDING SHALL
BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION
WHEN THE BUILDING REMAINS OCCUPIED. IN THE EVENT
THAT AN EXISTING MEANS OF EGRESS CANNOT BE
MAINTAINED, THE PRIME CONTRACTOR SHALL PROVIDE AN
APPROVED TEMPORARY MEANS OF EGRESS.
L. MAINTAIN THE INTEGRITY OF ALL EXISTING RATED
ELEMENTS, FIRE SEAL ANY PENETRATIONS WITH U.L.
APPROVED ASSEMBLY.
M. CONTRACTOR IS TO VERIFY THE EXACT LOCATION OF ALL
EXISTING UTILITIES PRIOR TO DEMOLITION ACTIVITIES.
N. DO NOT INTERRUPT EXISTING UTILITIES, EXCEPT WHEN
AUTHORIZED IN WRITING BY AHJ. PROVIDE TEMPORARY
SERVICES DURING INTERRUPTIONS TO EXISTING UTILITIES,
AS ACCEPTABLE TO GOVERNING AUTHORITIES.
O. WHEN UTILITY SERVICES ARE REQUIRED TO BE REMOVED,
RELOCATED, OR ABANDONED, PROVIDE BYPASS
CONNECTIONS TO MAINTAIN CONTINUITY OF SERVICE
BEFORE PROCEEDING WITH REMOVAL.
P. WHERE EXISTING INTERIOR PARTITIONS ARE REPLACED OR
REMOVED, REMOVE MEP SYSTEMS BACK TO PANEL, OR
MECHANICAL ROOM OR FARTHEST POSSIBLE POINT
WITHOUT DISTURBING EXISTING CONSTRUCTION, REMOVE
EXISTING MECHANICAL EQUIPMENT, RELOCATE POWER PER
MEP DRAWINGS
Q. ALL WALLS IN EXISTING ROOMS IN WHICH WORK IS
OCCURRING: A) REPAIR HOLES, DEFECTS, ETC. IN EXISTING
WALLS; B) AT REPAIRS AND UNPAINTED CMU, PROVIDE
BLOCK FILL PAINT AND TWO FINISH COATS OF PAINT; C)
PROVIDE ONE FINISH COAT OF PAINT OVER EXISTING
PAINTED WALLS.
R. PROTECT ALL DEVICES AND EQUIPMENT TO REMAIN OR BE
SALVAGED. REFER TO MECHANICAL AND ELECTRICAL
DRAWINGS.
11 22 33 55 66 77 88 1010 1111 121244 99
AA
BB
CC
DD
EE
FF6
/8
/8
D2
D2
D1
D5D5
D2
D2
D2 D2
D1D1
D1
D2
D1
D1
D1 D1
D2D2D2D2
D4
D2
D2
D2
D4
D1D1
D1
D1D1
D4
D4
D4
D4
D4
D4 D4
D4
D4 D4
D4 D4
D4
D4
D5
D1
D2
D2
D1
D1
D4
D4 D4
D6
D6 D6
D6
D6
D6
D6
D6
D6
D6
D6
D6
D9 D9 D6
D6
D6
D6
D6
D9
D9
D9
D9
D9
D9
D9 D9
D9 D9D9D9
D9 D9 D9 D9
D9 D9 D9 D9 D9 D9
D9
D10
H542
OFFICE
H544
OFFICE
H546
CONF
H548
OFFICE
H550
OFFICE
H564
OPEN
OFFICE
H540
OPEN
OFFICE
H576
OPEN
OFFICE
H578
OFFICE
H560
CONF
H562
CONF
H532
ELEC
H534
COMM
H515
WOMENS
H511
ELEV
H509
ELEV
H513
CORRIDOR
H501
ELEV
LOBBY
H505
ELEV
H503
ELEV
H507
STAIR
H553
STORAGE
H561
CORRIDOR
H594
COMM
H592
ELEC
H563
MENS
H571
EQUIP
H569
STORAGE
H573
JANITOR
H575
FREIGHT
ELEV H579
BREAK
ROOM
H577
VENDING
H567
STAIR
H570
ELEC
H572
COMM
H588
STORAGE
H523
CORR
H519
STAIR
H521
STORAGE
H522
COMM
H520
ELEC
H582
OFFICE
H530
OFFICE
H532
OPEN
OFFICE
H534
CONF
D3
D3
D7
A1-11
A1-11
D12
D13
D13
D8
D8
D8
D8
COORDINATE W/ NEW WORK
33' - 7 3/4"
C O
O R
D
IN
A T
E W
N
E W
W O
R K
/8
D11
C O
O R
D
IN
A T
E W
N
E W
W O
R K
/8
COORDINATE W/ NEW WORK
6' - 3 3/4"
D8
D8
D8
REMOVE TRAY THAT
EXTENDS INTO ROOM.
ENSURE DOORS ARE
SECURED IN CLOSED
POSITION.
N
/2
/4
R E
F E
R E
N C
E S
C A
L E
SHEET
PROJECT
PROJECT NO.
FILE NAME
DRAWN BY
DESIGNED BY
ORIGINAL ISSUE DATE
CLIENT PROJECT NO.
TITLE
REVIEWED BY
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
WITHOUT PRIOR WRITTEN CONSENT.
© 2024 I & S GROUP, INC.
1/21/2025 3:22:04 PM
A1-11
LEVEL 5
DEMOLITION
PLAN
DAS CC IDALS
HOOVER
DES MOINES IOWA
KKT
KKT
01/21/2025
EMS
9426.00
24-31954
5TH FLOOR
RENOVATION
A1-11 LEVEL 5 DEMOLITION PLAN
400 31954 A1-11
KEYNOTE LEGEND
D1 REMOVE/DEMOLISH EXISTING WALL AS INDICATED. PATCH
AND REPAIR ADJACENT WALL AND CEILING TO REMAIN.
D2 REMOVE/DEMOLISH EXISTING DOOR AND FRAME.
D3 CUT HOLE IN EXISTING WALL TO INCORPORATE NEW WORK.
D4 REMOVE EXISTING FLOOR COVERING, PREP SURFACE FOR
NEW FINISH.
D5 REMOVE/DEMOLISH EXISTING WINDOW GLAZING AND FRAME.
D6 REMOVE/DEMOLISH EXISTING STONE BASE THROUGHOUT
WORK AREA (NIC). PATCH AND REPAIR WALL AND PREPARE
FOR NEW FINISHES.
D7 REMOVE WHITEBOARD. PATCH AND REPAIR WALL.
D8 REMOVE AND SALVAGE EXISTING CEILING GRID, TILES, AND
ACCESSORIES - TURN OVER TO OWNER. REFER TO
ELECTRICAL FOR EXISTING LIGHT FIXTURES.
D9 REMOVE / DEMOLISH EXISTING VINYL BASE THROUGHOUT
WORK AREA. SKIM COAT WALL AND PREPARE FOR NEW BASE.
D10 REMOVE EXISTING HOLLOW METAL FRAME AND PREPARE
OPENING FOR NEW DOOR AND FRAME.
D11 DEMOLISH PORTION OF BULKHEAD AS REQUIRED FOR NEW
OPERABLE PARTITION WALL AND POCKET INSTALLATION.
COORDINATE WITH PARTITION WALL MFR REQ'S FOR POCKET
SIZE.
D12 REMOVE TRAY THAT EXTENDS INTO H569 FROM EQUIP H571.
REFER TO H569 DEMO PHOTO ON THIS SHEET.
D13 COORDINATE WITH OWNER FOR REMOVAL OF EXISTING
WALL-MOUNTED EQUIPMENT.
3/32" = 1'-0"4
LEVEL 5 DEMOLITION PLAN
1/8" = 1'-0"2
H560 AND H562 PARTIAL REFLECTED
CEILING DEMO PLAN
1/8" = 1'-0"1
H544 AND H546 PARTIAL REFLECTED
CEILING DEMO PLAN
NOT TO SCALE3
H569 DEMO PHOTO
WALL LEGEND
EXISTING CONSTRUCTION TO REMAIN
NEW CONSTRUCTION
FLOOR PLAN SHEET NOTES
• ALL INTERIOR PARTITION WALLS SHALL BE WALL TYPE A3,
UNLESS OTHERWISE NOTED.
• PATCH AND REPAIR ALL WALLS PRIOR TO PAINTING,
INCLUDING DAMAGE FROM REMOVAL OF EXISTING
EQUIPMENT AND ACCESSORIES.
• SKIM COAT WALL WHERE RUBBER BASE WAS REMOVED
FOR SMOOTH SUBSTRATE PRIOR TO NEW BASE INSTALL.
• INTERIOR WALL DIMENSIONS ARE FROM FACE OF EXISTING
FINISH AND FACE OF STUD WALL, UNLESS NOTED
OTHERWISE.
• PAINT ALL EXPOSED METALS INCLUDING, BUT NOT LIMITED
TO COLUMNS, RISERS, STRINGERS, HANDRAILS,
GUARDRAILS, EXPOSED LINTELS AND FLOOR EDGES,
UNLESS NOTED OTHERWISE.
• INSTALL FIRE TREATED BLOCKING AS REQUIRED IN ALL
PARTITIONS TO RECEIVE COUNTERS, SHELVING, MARKER
BOARDS, TV'S, ETC.
• ALL WALL MOUNTED ITEMS TO SIT FLUSH ON A WALL
SURFACE. IN INSTANCES WHERE A WALL MOUNTED ITEM IS
TO BE INSTALLED ON TWO DIFFERENT FINISH
THICKNESSES, PROVIDE A HARDBOARD BACKER FOR THE
ITEM TO SIT FLUSH. PROVIDE SEALANT AROUND ALL EDGES
OF BACKER AND PAINT TO MATCH ADJACENT SURFACE
• REVIEW ELECTRICAL BOXES IN WALLS THROUGHOUT
WORK AREA AND INFILL ALL UNUSED BOXES. COORDINATE
WITH CM AND ELECTRICAL CONTRACTOR.
11 22 33 55 66 77 88 1010 1111 121244 99
AA
BB
CC
DD
EE
FF
11 22 33 55 66 77 88 1010 1111 121244 99
AA
BB
CC
DD
EE
FF
H521
STORAGE H519
STAIR
H520
ELEC
H522
COMM
H532
ELEC
H534
COMM
H515
WOMENS
H553
STORAGE
H509
ELEV
H511
ELEV
H503
ELEV
H505
ELEV
H507
STAIR
H563
MENS
H594
COMM
H592
ELEC
H575
FREIGHT
ELEV
H571
EQUIP
H569
STORAGE
H567
STAIR
H577
VENDING
H588
STORAGE
H572
COMM
H570
ELEC
H523
CORR
OPEN TO BELOW
H579
BREAK
ROOM
H501
ELEV
LOBBY
H513
CORRIDOR
H540
OFFICE
COS
H542
OFFICE
SEC
H544
RR
H546
CONFERENCE
H548
OFFICE
D. SEC
H550
OFFICE
REG
H552
OFFICE
REG
H554
OFFICE
CFO
H568
OFFICE
STATE VET
H574
OFFICE
ASST VET
H576
OFFICE
ASST VET
H578
OFFICE
CLIMATE
H584
OFFICE
HR
H586
CONFIDENTIAL
ROOM
H560
CONFERENCE
H562
CONFERENCE
H558
OFFICE
LEGAL
H524
COLLABORATION
H518
CONFERENCE
H516
LARGE
CONFERENCE
H512
OFFICE
S / W
H514
OFFICE
S / W
H590
OPEN
OFFICE
H561
CORRIDOR
H564
OPEN
OFFICE
H538
OPEN
OFFICE
A1-41
A3
A3
H516B
H516A
H518
H512
H514
/8
/8
H
H
H
H
H
H
H544
H
H
H A
H A
H
H569
H568
H574
H576
H578
H584
H586
A3
A3
A3
10' - 9 5/8" 23' - 8 7/8" 5' - 10 7/8" 20' - 4 7/8" 20' - 0 7/8" 11' - 1 7/8" 11' - 1 7/8" 12' - 6 7/8"
/8
/8
16' - 1 1/4"
/8
/8
/8
/8
/8
/8
11' - 1 7/8" 14' - 11 7/8" 33' - 2 7/8" 1' - 5 1/8" ±
/8
/8
3' - 6" 1' - 6"
A1-41
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3 A3
A3
A3
A3
A3
A3
A3
A3
H545
KITCHENETTE
C L E
A R
C L
E A
R
CLEAR
15' - 4"
CLEAR
10' - 9"
CLEAR
23' - 4"
CLEAR
20' - 0"
CLEAR
19' - 8"
CLEAR
10' - 9"
CLEAR
10' - 9"
CLEAR
12' - 2"
C L E
A R
6' - 6"
CLEAR
15' - 9"
C L E
A R
C L E
A R
C L E
A R
C L E
A R
C L E
A R
C L E
A R
/8
H573
JANITOR
A1-41
C L E
A R
EQ EQ
8' - 0" 8' - 6"
VIF
20' - 10"
V
IF
V
IF
/8
7' - 3" 6' - 5"
A1-31 2 A1-31
1 1
H
H545
6 6
A3
/8
ALIGN
15' - 8 7/8"
ALIGNALIGN
C L E
A R
CLEAR
10' - 9"
CLEAR
14' - 7"
CLEAR
32' - 10"
A3
2' - 0"
2' - 0"
FURNITURE AND ELECTRICAL
IN THIS SPACE N.I.C.
A3
A3
A3
A3
18 18
A3
A3
H510
OPEN
OFFICE
"H510A
ALIGN
METAL FRAME
FRAME TYPES
METAL FRAME
2"
WIDTH
DOOR 2"
D O
O R
H E
IG
H
T
2" 3' - 0"
2"
2' - 0" 2"
5' - 6"
ALUMINUM FRAME
ALUMINUM FRAME
2" 3' - 0" 2" 3' - 10" 2" 3' - 10" 2" 3' - 10" 2" 3' - 10" 2" 3' - 10" 2"
23' - 4"
2" 3' - 0" 2" 3' - 11" 2" 3' - 11" 2" 3' - 11" 2" 3' - 11" 2"
19' - 8"
G2 G2 G2 G2 G2 G2 G2 G2 G2 G2
ALUMINUM FRAME
G2
2" 3' - 0" 2" 2' - 0" 2" 3' - 4" 2"
9' - 0"
G2 G2 G1
ALUMINUM FRAME
G2
2"3' - 0"2"2' - 0"2"4' - 4"2"
10' - 0"
G2G2G1
ALUMINUM FRAME
G2
2" 3' - 0" 2" 2' - 0" 2"2' - 11" 2" 2' - 11" 2"
11' - 8"
G2 G2 G1 G1
G2 G2 G1 G1 G1G1G1G1G1G2G2
FL
FLUSH
DOOR TYPES
NL
NARROW LITE
M A
X
6" 8"
W1
TRANSACTION
WINDOW TYPES
3' - 6"
1"x 1" ANODIZED
ALUMINUM CHANNEL
BUTT JOINT w/ CLEAR
SEALANT
G-3
1' - 6"3
OPENING w/ EASED
EXPOSED EDGES
1/4" SPEAK
HOLES IN
3 1/2" Ø
CIRCLE
N
/2
/4
R E
F E
R E
N C
E S
C A
L E
SHEET
PROJECT
PROJECT NO.
FILE NAME
DRAWN BY
DESIGNED BY
ORIGINAL ISSUE DATE
CLIENT PROJECT NO.
TITLE
REVIEWED BY
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
WITHOUT PRIOR WRITTEN CONSENT.
© 2024 I & S GROUP, INC.
1/21/2025 3:22:07 PM
A1-21
LEVEL 5 FLOOR
PLAN
DAS CC IDALS
HOOVER
DES MOINES IOWA
KKT
KKT
01/21/2025
EMS
9426.00
24-31954
5TH FLOOR
RENOVATION
A1-21 LEVEL 5 FLOOR PLAN
400 31954 A1-21
KEYNOTE LEGEND
1 PROVIDE BLOCKING IN WALL FOR MONITOR MOUNTING.
3 NEW CONFERENCE WALLS TO DECK IN ROOMS H560 / H562.
ALL OTHER WALLS TO UNDERSIDE OF EXISTING CEILING.
4 PANEL PARTITION WALL WITH INTEGRATED MARKER BOARD
EACH SIDE - 21'-2"W x 8'-6"H.
6 PATCH AND REPAIR GYPSUM BOARD FROM REMOVAL OF
STONE WALL BASE, FINISH TO MATCH EXISTING.
16 GYPSUM CONTROL JOINT EACH SIDE OF WALL ALIGNED
WITH OPERABLE PARTITION. PROVIDE BLOCKING IN WALL
PER OPERABLE PARTITION MFR REQ'S.
17 OPERABLE PARTITION WALL POCKET DEPTH AND WIDTH TO
BE COORDINATED WITH MFR REQUIREMENTS.
18 INFILL WINDOW OPENINGS WITH METAL STUD AND GYP TO
MATCH ADJACENT WALL.
20 PROVIDE BLOCKING IN WALL FOR MONITOR MOUNTING.
REMOVE GYPSUM AS REQUIRED FOR BLOCKING
INSTALLATION. PATCH WALL TO MATCH ADJACENT
SURFACES.
21 COORDINATE WITH OWNER FOR REINSTALLATION OF
WALL-MOUNTED EQUIPMENT.
22 DASHED LINE INDICATES CEILING SCOPE ON 4TH FLOOR:
REMOVE AND REINSTALL 4TH FLOOR CEILING TILES ONLY
AS REQUIRED FOR NEW WORK. ENSURE TILES ARE
INSTALLED PROPERLY AND LAYING FLAT WHEN WORK IS
COMPLETE. REFER TO PLUMBING DRAWINGS FOR
LOCATIONS OF PIPING.
3/32" = 1'-0"1
LEVEL 5 FLOOR PLAN
DOOR SCHEDULE
MARK ROOM NAME WIDTH HEIGHT
DOOR
TYPE DOOR MATERIAL
FRAME
TYPE FRAME MATERIAL
FIRE
RATING
POWER
REQUIRED
ACCESS
CONTROL
AUTO
OPERATOR
(ADA) HOLD OPEN
EGRESS
EXIT
HARDWARE
GROUP COMMENTS
H510A OPEN OFFICE 3' - 0" 7' - 0" FL HOLLOW METAL 1 HOLLOW METAL 7.0 PANIC BAR W/ LOCAL ALARM.
H512 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.
H514 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.
H516A LARGE CONFERENCE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 3.1 PASSAGE HARDWARE.
H516B LARGE CONFERENCE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 3.1 PASSAGE HARDWARE.
H518 CONFERENCE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 3.0 PASSAGE HARDWARE. FIELD VERIFY
WALL THICKNESS FOR FRAME DEPTH.
H540 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.1 SINGLE ACTION OFFICE HARDWARE.
H542 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.
H544 RR 3' - 0" 7' - 0" FL WOOD 1 HOLLOW METAL 2.0 SINGLE ACTION PRIVACY HARDWARE.
H545 KITCHENETTE 3' - 0" 7' - 0" FL WOOD 1 HOLLOW METAL 4.0 PASSAGE HARDWARE.
H546 CONFERENCE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 3.0 PASSAGE HARDWARE.
H548 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.
H550 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.
H552 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.
H554 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.
H558 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.
H560 CONFERENCE 3' - 0" 7' - 0" NL WOOD 1 HOLLOW METAL ● ● 6.1 LOCK W/ CARD READER.
H560A CONFERENCE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM ● ● 6.0 LOCK W/ CARD READER.
H562 CONFERENCE 3' - 0" 7' - 0" NL WOOD 1 HOLLOW METAL ● ● 6.0 LOCK W/ CARD READER.
H562A CONFERENCE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM ● ● 6.0 LOCK W/ CARD READER.
H568 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.
H569 STORAGE 3' - 0" 6' - 9 3/4" FL WOOD 1 HOLLOW METAL 5.0 STOREROOM HARDWARE.
FIELD VERIFY EXISTING OPENING.
H574 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.
H576 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.
H578 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.
H584 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.
H586 CONFIDENTIAL ROOM 3' - 0" 7' - 0" NL WOOD 1 HOLLOW METAL 1.0 SINGLE ACTION OFFICE HARDWARE.
GLAZING SCHEDULE
MARK MATERIAL THICKNESS COMMENTS
NON-INSULATED
G-1 GLAZING UNIT 1/4"
G-2 GLAZING UNIT,
TEMPERED
1/4"
G-3 GLAZING UNIT,
TEMPERED
3/8"
DOOR SCHEDULE GENERAL NOTES:
1. CARD READER PROVIDED AND INSTALLED BY OWNER. ROUGH IN FOR CARD READER BY CONTRACTOR.
2. DOOR HARDWARE STYLE AND FINISH TO MATCH EXISTING HARDWARE TO REMAIN. COORDINATE WITH SPEC AND OWNER.
F
F F F F FF
F
F
FF F F F F
G F
I V
S V
S
V S
F
F F
F
TT
T
T
T
T
T
T
T T
T
T
TT T T T T T
T
T T
T
T
T
T
T
T TT
T
T T
T
T
T
T
T
T
T
RCP SHEET NOTES
• COORDINATE WITH MECHANICAL, PLUMBING, FIRE
PROTECTION AND ELECTRICAL FOR EXACT LOCATIONS
OF CEILING FIXTURES, DIFFUSERS, SPRINKLER HEADS,
ETC.
• REFER TO HVAC PLANS FOR THE LOCATION OF ANY AND
ALL PLENUM CEILING SPACES. ALL WALLS AND SOFFITS
CREATING THE PLENUM SHALL EXTEND TO THE
UNDERSIDE OF STRUCTURE ABOVE AND BE SEALED.
• ENSURE ALL CEILING TILES ARE LAYING FLAT PRIOR TO
PAINTING.
11 22 33 55 66 77 88 1010 1111 121244 99
AA
BB
CC
DD
EE
FF
11 22 33 55 66 77 88 1010 1111 121244 99
AA
BB
CC
DD
EE
FF
H564
OPEN
OFFICE
H538
OPEN
OFFICE
H590
OPEN
OFFICE
H524
COLLABORATION
H579
BREAK
ROOM
H512
OFFICE
H514
OFFICE
H516
LARGE
CONFERENCE
H518
CONFERENCE
H523
CORR
H568
OFFICE
H574
OFFICE
H576
OFFICE
H578
OFFICE
H584
OFFICE
H586
CONFIDENTIAL
ROOM
H554
OFFICE
H552
OFFICE
H550
OFFICE
H548
OFFICEH546
CONFERENCE
H558
OFFICE H560
CONFERENCE
H562
CONFERENCE
H542
OFFICE
H540
OFFICE
H544
RR
H561
CORRIDOR
H569
STORAGE
ACT-1
9' - 0"
ACT-1
9' - 0"
GYP BD
8' - 6"
H519
STAIR
H521
STORAGE
H515
WOMENS
H511
ELEV
H509
ELEV
H553
STORAGE
H513
CORRIDOR
H501
ELEV
LOBBY
H503
ELEV
H505
ELEV
H507
STAIR
H563
MENS
H571
EQUIP
H567
STAIR
H577
VENDING
H575
FREIGHT
ELEV
H545
KITCHENETTE
PNT-3
A1-31
PNT-3 PNT-3
PNT-3
PNT-3 PNT-3
PNT-3
PNT-3
PNT-3
PNT-3
PNT-3
PNT-3
PNT-3
PNT-3
PNT-3 PNT-3 PNT-3
PNT-3
PNT-3
PNT-3
PNT-3
PNT-3
PNT-3
PNT-3
PNT-3
PNT-3
PNT-3PNT-3
PNT-3 PNT-3 PNT-3
PNT-3
PNT-3
PNT-3
PNT-3
PNT-3
PNT-3
A1-31
GYP BD
9' - 0"
H510
OPEN
OFFICE
FOAM TAPE
.060 THICKNESS BREAK
METAL. COLOR TO MATCH
STOREFRONT/ CURTAIN
WALL
DOUBLE STICK TAPE EA. SIDE
RIGID INSULATION
WALL BELOW
5/8" GYP. BD. SEE WALL TYPES.
LIGHT GAUGE METAL STUD
SOUND ATTENUATION
INSULATION. REFER TO WALL
TYPES.
EXISTING SILL BELOW
FOAM TAPE
.060 THICKNESS BREAK
METAL. COLOR TO MATCH
STOREFRONT/ CURTAIN
WALL
DOUBLE STICK TAPE EA. SIDE
RIGID INSULATION
WALL BELOW
5/8" GYP. BD. SEE WALL TYPES.
LIGHT GAUGE METAL STUD
SOUND ATTENUATION
INSULATION. REFER TO WALL
TYPES.
EXISTING SILL BELOW
EXISTING STOREFRONT
FRAME
HANGER RODS BY
OPERABLE WALL
CONTRACTOR. FOR
SUPPORT ABOVE, REFER
TO DETAIL
5/8" GYPSUM BOARD,
TYPICAL
HANGER BRACKET
VINYL SEAL
EQ EQ
SUSPENDED
ACOUSTICAL CEILING
TILE ASSEMBLY
3 5/8" METAL
STUDS @ 16" OC
CONTINUOUS
REMOVABLE GYP BOARD
PANEL FOR ACCESS TO
HANGER RODS
REFER TO PLAN
FOLDING PANEL
PARTITION
4/ A1-31
METAL STUD BOX HEADER
SOUND ATTENUATION
BLANKET WHERE INDICATED.
3 5/8" METAL STUDS TO
UNDERSIDE OF EXISTING
CEILING, UNO
5/8" GYP. BOARD, TYPICAL
HOLLOW METAL FRAME
SEALANT ALL SIDES OF FRAME
REFER TO DOOR SCHEDULE
FOR DOOR TYPE
METAL STUD BOX HEADER
SOUND ATTENUATION
BLANKET WHERE INDICATED.
5/8" GYP. BOARD,
TYPICAL
3/8" TREATED
WOOD SHIM
TRANSOM HEAD
DOOR HEAD
SEALANT WITH BACKER
ROD EACH SIDE
ALUMINUM
STOREFRONT FRAMING
ALUMINUM DOOR, REFER
TO DOOR SCHEDULE
EXISTING CEILING
TO REMAIN, PAINT
KICKER AT EACH
EXTENDED STUD,
ALTERNATE DIRECTIONS
EXTEND 1 STUD ABOVE CEILING
TILE EVERY 4'-0". NOTCH
EXISTING METAL CEILING TILE
AS REQ'D. NOTCH TO BE CUT
TIGHT TO STUD AS TO NOT BE
VISIBLE WHEN GYPSUM BOARD
IS INSTALLED.
SEALANT (BOTH SIDES OF FRAME)
HOLLOW METAL FRAME W/
METAL STUD ANCHORS.
1/4" GLAZING, SEE SCHEDULE W/
APPLIED CONTINUOUS STOPS
METAL STUDS, SOUND
ATTENUATION INSULATION, AND
GYP BD. REFER TO WALL TYPES.
METAL STUDS, SOUND
ATTENUATION INSULATION, AND
GYP BD. REFER TO WALL TYPES.
SEALANT (BOTH
SIDES OF FRAME)
1/4" GLAZING - REFER TO SCHEDULE W/
APPLIED CONTINUOUS STOPS
METAL STUD BOX HEADER
HOLLOW METAL FRAME.
REFER TO SCHEDULE.
HOLLOW METAL FRAME
SEALANT BOTH
SIDES OF FRAME
REFER TO DOOR SCHEDULE
FOR DOOR TYPE
SOUND ATTENUATION
BLANKET WHERE INDICATED.
5/8" GYP. BOARD, TYPICAL
METAL STUDS, REFER TO
PLAN AND WALL TYPES.
ACT-1
9' - 0"
5/8" TYPE 'X'
GYP BD
SOUND BATT
INSULATION
3 5/8" METAL
STUDS
EXISTING
STRUCTURE
ABOVE
EXISTING METAL
CEILING TILE
PROVIDE
SEALANT AT
TOP OF WALL,
BOTH SIDES
1/2"
/2
/2
PARTITION ATTACHMENTS
PER MANUFACTURER
W8X18 BETWEEN CONCRETE
WEBS WHERE PARTITION
ATTACHMENTS ARE REQUIRED
(2) ASTM A325 3/4"⌀ BOLTS
GROUP A-N, TYPICAL
L4X3.5X3/84"
NOTE: FIELD VERIFY BEAM
PLACEMENTS WITH PARTITION
ATTACHMENT LOCATIONS
N
/2
/4
R E
F E
R E
N C
E S
C A
L E
SHEET
PROJECT
PROJECT NO.
FILE NAME
DRAWN BY
DESIGNED BY
ORIGINAL ISSUE DATE
CLIENT PROJECT NO.
TITLE
REVIEWED BY
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
WITHOUT PRIOR WRITTEN CONSENT.
© 2024 I & S GROUP, INC.
1/21/2025 3:22:13 PM
A1-31
LEVEL 5
REFLECTED
CEILING PLAN
AND DETAILS
DAS CC IDALS
HOOVER
DES MOINES IOWA
KKT
KKT
01/21/2025
EMS
9426.00
24-31954
5TH FLOOR
RENOVATION
A1-31 LEVEL 5 REFLECTED CEILING PLAN AND DETAILS
400 31954 A1-31
KEYNOTE LEGEND
5 NEW 24"X24" ACCESS PANEL IN CEILING. LOCATE PIPES
PRIOR TO INSTALLATION, COORDINATE FINAL ACCESS
PANEL LOCATION WITH PIPES. ALIGN ACCESS PANEL WITH
EXISTING CEILING TILE SEAMS WHERE POSSIBLE.
8 MODIFY CEILING GRID AND TILES AS REQUIRED FOR NEW
WALL INSTALLATION WITH CLEAN CUTS AND TRANSITIONS
FOR A FINISHED END PRODUCT. REUSE COMPONENTS
WHERE POSSIBLE, PROVIDE NEW COMPONENTS AS
NECESSARY.
19 ALIGN NORTH FACE OF POCKET WITH EXISTING NORTH
FACE OF BULKHEAD.
3/32" = 1'-0"8
LEVEL 5 REFLECTED CEILING PLAN
3" = 1'-0"1
INTERIOR WALL TO GLAZING
3" = 1'-0"2
INTERIOR WALL TO MULLION
1 1/2" = 1'-0"3
FOLDING PANEL PARTITION HEAD
1 1/2" = 1'-0"9
HM DOOR HEAD AT METAL STUDS
1 1/2" = 1'-0"11
ALUM HEAD AT METAL STUDS
1 1/2" = 1'-0"5
HM LITE JAMB AT METAL STUDS
1 1/2" = 1'-0"6
HM LITE HEAD AT METAL STUDS
1 1/2" = 1'-0"7
HM DOOR JAMB AT METAL STUDS
3/4" = 1'-0"10
TOP OF WALL AT CONF
ROOMS H560 & H562
1 1/2" = 1'-0"4
PARTITION SUPPORT DETAIL
C
W
B
F
ROOM #
ROOM NAME
CEILING
WALL
BASE
FLOOR
FINISHES LISTED IN ROOM
TAG APPLY TO ALL
ELEMENTS IN ROOM,
UNLESS NOTED OTHERWISE
THE FOLLOWING SYMBOL
APPLIES TO FINISHES
DIFFERENT FROM THOSE
NOTED IN ROOM TAG:
FIN#
ROOM / FINISH TAG
THE FOLLOWING SYMBOL
INDICATES: "REFER TO
ELEVATIONS" FOR
ADDITIONAL FINISH
INFORMATION
FIN#
H521
STORAGE
H519
STAIR
H520
ELEC
H522
COMM
H532
ELEC
H534
COMM
H515
WOMENS
H553
STORAGE
H509
ELEV
H511
ELEV
H503
ELEV
H505
ELEV
H507
STAIR
H563
MENS
H594
COMM
H592
ELEC
H575
FREIGHT
ELEV
H571
EQUIP
C
W
B
F
H569
STORAGE
EXIST
EXIST
B-1
SC
H567
STAIR
H577
VENDING
C
W
B
F
H588
STORAGE
PNT-3
PNT-1
EXIST
EXIST
H572
COMM
H570
ELEC
H523
CORR
H579
BREAK
ROOM
H501
ELEV
LOBBY
H513
CORRIDOR
C
W
B
F
H540
OFFICE
PNT-3
PNT-1
B-1
CPT-1
C
W
B
F
H542
OFFICE
PNT-3
PNT-1
B-1
CPT-1
C
W
B
F
H544
RR
PNT-2
PNT-1
B-1
LVT-1
C
W
B
F
H546
CONFERENCE
PNT-3
PNT-1
B-1
CPT-1
C
W
B
F
H548
OFFICE
PNT-3
PNT-1
B-1
CPT-1
C
W
B
F
H550
OFFICE
PNT-3
PNT-1
B-1
CPT-1
C
W
B
F
H552
OFFICE
PNT-3
PNT-1
B-1
CPT-1
C
W
B
F
H554
OFFICE
PNT-3
PNT-1
B-1
CPT-1
C
W
B
F
H568
OFFICE
PNT-3
PNT-1
B-1
CPT-1
C
W
B
F
H574
OFFICE
PNT-3
PNT-1
B-1
CPT-1
C
W
B
F
H576
OFFICE
PNT-3
PNT-1
B-1
CPT-1
C
W
B
F
H578
OFFICE
PNT-3
PNT-1
B-1
CPT-1
C
W
B
F
H584
OFFICE
PNT-3
PNT-1
B-1
CPT-1
C
W
B
F
H586
CONFIDENTIAL
ROOM
PNT-3
PNT-1
B-1
CPT-1
C
W
B
F
H560
CONFERENCE
PNT-3
PNT-1
B-1
CPT-1
C
W
B
F
H562
CONFERENCE
PNT-3
PNT-1
B-1
CPT-1
C
W
B
F
H558
OFFICE
PNT-3
PNT-1
B-1
CPT-1
C
W
B
F
H524
COLLABORATION
PNT-3
PNT-1/2
B-1
CPT-1
C
W
B
F
H518
CONFERENCE
PNT-3
PNT-1
B-1
CPT-1
C
W
B
F
H516
LARGE
CONFERENCE
PNT-3
PNT-1
B-1
CPT-1
C
W
B
F
H512
OFFICE
PNT-3
PNT-1
B-1
CPT-1
C
W
B
F
H514
OFFICE
PNT-3
PNT-1
B-1
CPT-1
C
W
B
F
H590
OPEN
OFFICE
PNT-3
PNT-1
B-1
CPT-1
H561
CORRIDOR
C
W
B
F
H564
OPEN
OFFICE
PNT-3
PNT-1
B-1
CPT-1
C
W
B
F
H538
OPEN
OFFICE
PNT-3
PNT-1
B-1
CPT-1
C
W
B
F
H545
KITCHENETTE
PNT-2
PNT-1
B-1
LVT-1
PNT-EX
PN
T-
PN
T-
PN
T-
PN
T-
PN
T-
PN
T-
PN
T-
PN
T-
2 PN
T-
PN
T-
PN
T-
PN
T-
PN
T-
PN
T-
PNT-2 PNT-2
PNT-2
PN
T-
PNT-2
PN
T-
PNT-2
PN
T-
PN
T-
PN
T-
PN
T-
PN
T-
PN
T-
C
W
B
F
H510
OPEN
OFFICE
PNT-3
PNT-1
B-1
CPT-1
AA
H544
A1-41
5' - 10 7/8"
H544
RR
H545
KITCHENETTE
A3
A3
A3
A1-41 6
H545
1' - 5"
FD
/8
2' - 10"
3' - 0" 2' - 6"
PLAM-1
B-1
PNT-EX
PLAM-1
A1-41
A1-41
PLAM-2
FILLER FILLER
6' - 0"
A1-41
A1-41
PNT-1
3' - 6"
W1
A1-41
PNT-EX
TPD
R1A
SD
MR1
GB3
GB2
B-1
PNT-EX
B-1
TPD
PNT-EX
R1A
GB1
GB3
1' - 6"
PLAM WRAP, REFER TO
FINISH ELEVATIONS
1/2" PLYWOOD TYPICAL
HEAVY DUTY BLIND METAL
SHELF BRACKETS AND
POSTS
1" MELAMINE TOP, DOWELED &
GLUED
1/2" MELAMINE BACK LET IN SIDES,
TOP, BOTTOM (HOT GLUE
PERIMETER)
1" ADJUSTABLE MELAMINE SHELVES
3/4" MELAMINE SIDES, DOWELED &
GLUED (PLAM FINISHED END'S AS
NOTED)
1" PLAM BOTTOM, DOWELED &
GLUED
1' - 2"
3/4" PLAM DOOR
R E
F E
R T
O E
L E
V A
T
IO
N S
PLAM COUNTERTOPS W/ 4" BACK
SPLASH. HEAVY GAUGE BACKER
SHEET
3/4" MELAMINE SUBTOP,
DOWELED & GLUED
1" ADJUSTABLE MELAMINE SHELF
1/2" MELAMINE BACK HOUSED IN
SIDES (HOT GLUED AT PERIMETER)
3/4" MELAMINE SIDES, DOWELED
& GLUED. (PLAM FE'S AS NOTED)
3/4" MELAMINE BOTTOM
DOWELED & GLUED
ELEVATIONS
REFER TO
R E
F E
R T
O E
L E
V A
T
IO
N S
/2
3/4" PLAM DRAWER AND DOOR
PULLS
BASE, REFER TO FINISH PLANS4
1 1/2"
/2
/2
M
IN
2' - 0"
M
IN
11" MIN.
8" MIN.
REFER TO ELEVATIONS FOR FINISHES
AND CTOP EDGE STYLE
WALL LINE
1 1/2" THICK PLASTIC LAMINATE
FINISHED SUPPORT PANELS
BETWEEN EACH SINK- TYP.
SECURE TO WALL. PROVIDE
METAL THREADED INSERTS
FOR REMOVABLE PANEL
COUNTERTOP W/ SINK,
REFER TO SPECS FOR SINK
TYPE
2x4 HARDWOOD
BLOCKING CONT.
3/4" THICK REMOVABLE PLASTIC
LAMINATE FACED SHROUD-
SPLIT @ SUPPORTS BETWEEN
SINKS. PROVIDE 3 VANDAL
RESISTANT HEAD SCREWS @
EACH SIDE OF PANEL
CC
3.05 New Fifth Floor
142' - 0"
1"
9 7/8"
/2
CLEAR SILICONE SEALANT
@ PERIMETER OF ALUM.
CHANNEL, BOTH SIDES
ALUMINUM CHANNEL,
TOP AND BOTTOM
3/8" CLEAR TEMPERED
GLAZING
SOLID SURFACE
TRANSACTION TOP
4" MAX
CORRIDOROFFICE
SD
PTD
B-1
PNT-EX
N
/2
/4
R E
F E
R E
N C
E S
C A
L E
SHEET
PROJECT
PROJECT NO.
FILE NAME
DRAWN BY
DESIGNED BY
ORIGINAL ISSUE DATE
CLIENT PROJECT NO.
TITLE
REVIEWED BY
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
WITHOUT PRIOR WRITTEN CONSENT.
© 2024 I & S GROUP, INC.
1/21/2025 3:22:20 PM
A1-41
LEVEL 5 FINISH
PLAN &
SCHEDULE
DAS CC IDALS
HOOVER
DES MOINES IOWA
KKT
KKT
01/21/2025
EMS
9426.00
24-31954
5TH FLOOR
RENOVATION
A1-41 LEVEL 5 FINISH PLAN & SCHEDULE
400 31954 A1-41
KEYNOTE LEGEND
2 PAINT SIDE OF DOOR FRAMES WITHIN THE NEW WORK AREA
ON EXISTING DOORS. TRANSITION COLOR AT THE DOOR
STOP SO ONLY ONE FRAME COLOR IS VISIBLE FROM EACH
SIDE.
7 PAINT BOTH SIDES OF DOOR FRAME.
10 PAINT WALL TO MATCH EXISTING.
11 CLEAN AND PAINT EXPOSED MASONRY.
12 REFRIGERATOR BY OWNER.
13 MICROWAVE BY OWNER.
14 COFFEE MAKER BY OWNER.
15 UNDER-COUNTER REFRIGERATOR BY OWNER.
INTERIOR FINISH SCHEDULE
MARK MATERIAL TYPE MANUFACTURER MODEL / SIZE COLOR ADDITIONAL INFORMATION COMMENTS
CEILING
ACT-1 ACOUSTIC CEILING
TILE
ARMSTRONG 584B HUMIGUARD PLUS
24"x24"x7/8"
TO MATCH EXISTING CORRIDOR H561 ACT
DOORS
WD-1 WOOD WHITE OAK ALPINE, AL18 MATCH EXISTING WOOD DOORS.
FLOOR
CPT-1 CARPET TILE SHAW CONTRACT DIFFUSE COLOR 24x24
ECOWORX
78721 WARM BLUE STYLE #5T478 COORDINATE PATTERN / DIRECTION WITH
OWNER. PROVIDE TRANSITIONS TO
DIFFERENT MATERIALS UNDER DOORS.
LVT-1 LUXURY VINYL TILE MOHAWK REFORESTATION 862 MARION COORDINATE PATTERN / DIRECTION WITH
OWNER. PROVIDE TRANSITIONS TO
DIFFERENT MATERIALS UNDER DOORS.
SC SEALED CONCRETE LATICRETE
INTERNATIONAL
L&M DRESS & SEAL CLEAN AND SEAL EXISTING CONCRETE
PLASTIC LAMINATE
PLAM-1 PLASTIC LAMINATE ARBORITE W449 EV RIFT NATURAL OAK MILLWORK
PLAM-2 PLASTIC LAMINATE ARBORITE P396 VL ARCTIC TUNDRA COUNTERTOPS
WALL
PNT-1 PAINT SHERWIN WILLIAMS SW7015 REPOSE GRAY WALLS & PILLARS
PNT-2 PAINT SHERWIN WILLIAMS SW6230 RAINSTORM ACCENT PAINT
PNT-3 PAINT SHERWIN WILLIAMS B42W02181 WHITE PRO INDUSTRIAL WATERBORNE
ACRYLIC DRYFALL FLAT
CEILINGS
PNT-4 PAINT SHERWIN WILLIAMS SW7019 GAUNTLET GRAY DOOR FRAMES
PNT-EX PAINT SHERWIN WILLIAMS MATCH ADJACENT
WALLS
PAINT TO INSIDE CORNERS FOR
CLEAN TRANSITION
WALLS
WALL BASE
B-1 VINYL BASE JOHNSONITE #48 GREY INSTALL ON ALL CASEWORK TOE
KICKS, U.N.O.
3/32" = 1'-0"13
LEVEL 5 FINISH PLAN
1/4" = 1'-0"1
ENLARGED RR H544 /
KITCHENETTE H545
3/8" = 1'-0"2
KITCHENETTE H545
3/8" = 1'-0"3
COLLABORATION H524
3/8" = 1'-0"4
CORRIDOR H561
3/8" = 1'-0"6
RR H544 - EAST
3/8" = 1'-0"7
RR H544 - SOUTH
EQUIPMENT SCHEDULE
MARK DESCRIPTION COMMENTS
PROVIDED
BY
INSTALLED
BY
GB1 36" HORIZONTAL GRAB BAR INSTALL BLOCKING FOR GRAB BAR.
GRAB BAR TO BE INSTALLED IN
FUTURE.
CONTRACTOR CONTRACTOR
GB2 42" HORIZONTAL GRAB BAR INSTALL BLOCKING FOR GRAB BAR.
GRAB BAR TO BE INSTALLED IN
FUTURE.
CONTRACTOR CONTRACTOR
GB3 18" VERTICAL GRAB BAR INSTALL BLOCKING FOR GRAB BAR.
GRAB BAR TO BE INSTALLED IN
FUTURE.
CONTRACTOR CONTRACTOR
MR1 Mirror 24"x36" CONTRACTOR CONTRACTOR
PTD Touchless Paper Towel Dispenser GP-59462A OWNER CONTRACTOR
SD Automated Touchless Soap Dispenser GJ-P191904 OWNER CONTRACTOR
TPD 2-Roll Side-by-Side Toilet Paper Dispenser 56784 OWNER CONTRACTOR
1 1/2" = 1'-0"8
FLOATING SHELF
1" = 1'-0"9
UPPER CABINET
1" = 1'-0"10
BASE CABINET
1" = 1'-0"11
ADA SINK CABINET DETAIL
3/4" = 1'-0"12
TRANSACTION WINDOW
EQUIPMENT SCHEDULE GENERAL NOTES:
1. COORDINATE FINAL INSTALLATION LOCATIONS WITH OWNER.
3/8" = 1'-0"5
RR H544 - NORTH
24/12
FIRE/SMOKE DAMPER
SMOKE DAMPER
FIRE DAMPER
MANUAL DAMPER
GRAVITY BACKDRAFT
DAMPER
MOTORIZED DAMPER
GALVANIZED
STEEL ELBOW
FLEX DUCT
(5'-0" MAX. LENGTH
OF ONE BRANCH) GALVANIZED STEEL
ELBOW AT DIFFUSER
CONNECTION
DIFFUSER
VOLUME
DAMPER
TAKE-OFF
CEILING
RADIATION
DAMPER
EXISTING
DUCTWORK
TO REMAIN
DEMOLISHED
DUCTWORK
BRANCH BALANCING DAMPER
DUCT SIZE
IN FREE
AREA
45 DEGREE
SHOE-TAP
TAKE-OFF
MITERED
ELBOWS
TURNING
VANES
EXHAUST OR
RETURN AIR
INLET
EXHAUST OR RETURN
AIR GRILLE
TYPICAL FLEXIBLE
DUCT CONNECTION
(BEFORE AND AFTER
EQUIPMENT)
NOTES:
• THIS DRAWING IS FOR INFORMATIONAL
PURPOSES ONLY. ITEMS SHOWN ARE NOT
NECESSARILY USED ON THIS PROJECT.
• DUCT SIZE: FIRST NUMBER INDICATES
DIMENSION OF SIDE SHOWN. THE SECOND
NUMBER INDICATES SIDE NOT SHOWN
- RECTANGULAR DUCT SIZEXX/XX
- ROUND DUCT SIZEX"Ø
- FLAT OVAL DUCT SIZEXX/XX"Ø
- CONNECT TO EXISTING
- THERMOSTAT
- TEMPERATURE SENSOR (DDC)
- HUMIDITY SENSOR
- DUCT SMOKE DETECTOR
- CARBON MONOXIDE SENSOR
- CARBON DIOXIDE SENSOR
- NITROGEN DIOXIDE SENSOR
- PRESSURE SENSOR
SYMBOL LEGEND
DUCTWORK LEGENDHVAC PIPING LEGEND
- HYDRONIC WATER SUPPLYHWS
- HYDRONIC WATER RETURNHWR
- LOW PRESSURE STEAMSTM-L#
- LOW PRESSURE CONDENSATE RETURNCD-L#
- CHILLED WATER SUPPLYCWS
- CHILLED WATER RETURNCWR
A-XX/XX
CFM
GRILLE, REGISTER, DIFFUSER TYPE.
DESIGN CFM
GRILLE, REGISTER, DIFFUSER TAG
A - Ø"
EXTERNAL
INSULATED
DUCT
LINED
DUCTWORK
UNLINED
DUCTWORK
EQUIPMENT
ROUND
SPIN-IN
TAKE-OFF
ACCESS PANEL
FOR TURNING VANES
DUCT INLET SIZE
- SUPPLY AIR DUCT UP / DOWN
- RETURN AIR DUCT UP / DOWN
- EXHAUST AIR DUCT UP / DOWN
DUCTWORK SYMBOLS
- CONDENSER WATER SUPPLYCNDS
- CONDENSER WATER RETURNCNDR
FABRIC DUCT SPIRAL DUCT
- BALL VALVE
- BUTTERFLY VALVE
- GATE VALVE
- GAS COCK
- CHECK VALVE
- IN LINE PUMP
- STRAINER
- BALANCING VALVE
- UNION
- PIPING DROP
- INLINE PIPING DROP
- PIPING RISE
- PIPE CAP
- PIPE BREAK
- GLOBE VALVE (NORMALLY CLOSED)
- RELIEF VALVE
FOS
FOR
FUEL OIL SUPPLY
FUEL OIL RETURN
DOMESTIC HOT WATER
DOMESTIC COLD WATER
VENT
DOMESTIC HOT WATER
RECIRCULATION
NATURAL GAS
SANITARY WASTE
- METER
- WALL / END CLEANOUT
- THERMOMETER
- FLOOR DRAIN
- FLOOR SINK
- WALL HYDRANT/ HOSE BIBB
REDUCED PRESSURE PRINCIPLE
BACKFLOW PREVENTER
M
NG
W
V
DCW
DHW
DHWR
FP-W
LIQUID PROPANE
GREASE VENT
GREASE WASTE
FIRE PROTECTION - WET
CONDENSATE DRAIN
COMPRESSED AIR
CD
CA
GW
GV
LP
SANITARY ACID VENT
SANITARY ACID WASTEAW
AV
ST-O STORM OVERFLOW
ST-P STORM PRIMARY
- ISOLATION VALVE
PIPING SYMBOLS
- CLEAN OUT
PLUMBING PIPING LEGEND
IFS
IFR
- IN FLOOR HEATING SUPPLY
- IN FLOOR HEATING RETURN
- GLOBE VALVE
- GATE VALVE (NORMALLY CLOSED)
- NEEDLE VALVE (NORMALLY CLOSED)
- NEEDLE VALVE
- FLEXIBLE CONNECTOR
- 2 WAY CONTROL VALVE
- 3 WAY CONTROL VALVE
RS
RL
- REFRIGERATION SUCTION
- REFRIGERATION LIQUID
T
T S
H
P
NO2
CO2
CO
SD
- INLINE PIPING RISE
FP-D FIRE PROTECTION - DRY
FP-PA FIRE PROTECTION - PRE-ACTION
PIPING TAGS
##"-XXX
NOMINAL PIPE SIZE
PIPE SYSTEM ABBREVIATION
##"-XXX (##) FIXTURE UNITS / FLOW
SHEET ANNOTATION SYMBOLS
01 - KEYNOTE
01 - REVISION NUMBER
- DETAIL NUMBER ON SHEET
- SHEET NUMBER
TYPICAL ANNOTATIONS
A.F.F. - ABOVE FINISH FLOOR
EA - EXHAUST AIR
OA - OUTSIDE AIR (UNCONDITIONED)
RA - RETURN AIR
SA - SUPPLY AIR
N.I.C. - NOT IN CONTRACT
BOB - BOTTOM OF BEAM
BOD - BOTTOM OF DUCT
BOJ - BOTTOM OF JOIST
BOP - BOTTOM OF PIPE
BOS - BOTTOM OF STEEL
CL - CENTERLINE
DN - DOWN
DIA - DIAMETER
FT - FEET
HD - HEAD
HP - HORSEPOWER
KW - KILOWATT
PH. - PHASE
GC - GENERAL CONTRACTOR
MC - MECHANICAL CONTRACTOR
PC - PLUMBING CONTRACTOR
MFR - MANUFACTURER
NC - NORMALLY CLOSED
NO - NORMALLY OPEN
OFCI - OWNER FURNISHED,
CONTRACTOR INSTALLED
OFOI - OWNER FURNISHED,
OWNER INSTALLED
PD - PRESSURE DROP (FEET)
PSIA - POUNDS PER SQUARE INCH,
ATMOSPHERIC
RPM - REVOLUTIONS PER MINUTE
BTU/H - BRITISH THERMAL
UNITS PER HOUR
CFM - CUBIC FEET PER MINUTE
ACH - AIR CHANGES PER HOUR
GPM - GALLONS PER MINUTE
MBH - THOUSANDS OF BTUs PER HOUR
A - AMPS
MCA - MINIMUM CIRCUIT AMPACITY
MOCP - MAXIMUM OVER CURRENT PROTECTION
PSIG - POUNDS PER SQUARE INCH,
GAUGE
FPM - FEET PER MINUTE
DB - DECIBELS
DDC - DIRECT DIGITAL CONTROL
ESP - EXTERNAL STATIC PRESSURE
EAT - ENTERING AIR TEMPERATURE (°F)
LAT
EWT
LWT
- LEAVING AIR TEMPERATURE (°F)
- ENTERING WATER TEMPERATURE (°F)
- LEAVING WATER TEMPERATURE (°F)
NC - NOISE CRITERIA
RH - RELATIVE HUMIDITY
BMS - BUILDING MANAGEMENT SYSTEM
FDC - FIRE DEPARTMENT CONNECTION
FLA - FULL LOAD AMPS
TOB - TOP OF BEAM
TOD - TOP OF DUCT
TOP - TOP OF PIPE
TOS - TOP OF STEEL
UP - UP
V / VOLT. - VOLTAGE
TYP. - TYPICAL
TSP - TOTAL STATIC PRESSURE
VFD - VARIABLE FREQUENCY DRIVE
VTR - VENT THROUGH ROOF
TON - TON OF COOLING (12,000 BTU/H)
- PIPE ANCHOR
- PIPE GUIDE
- STEAM TRAP
##' - ##" - SPOT ELEVATION
(BOTTOM OF ELEMENT)
DEMOLISHED
E…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .