RFB942600-01 - DAS CC IDALS Hoover - Drawings.pdf

PDF 13 MB Posted

Attached to
DAS CC IDALS Hoover 5th Floor Renovation
Solicitation number
RFB942600-01
Issued by
Polk County, Des Moines City, Iowa

About this file

This appears to be a set of architectural drawings file (RFB942600-01) related to a renovation project for the Iowa Department of Administrative Services (DAS) and Iowa Department of Agriculture and Land Stewardship (IDALS) at the Hoover Building's 5th floor. However, there seems to be a discrepancy in the description as it mentions "CDC Warehouse" and "Individual Serving Drink Mix," which does not align with the file name indicating building renovation drawings. Without access to view the actual drawings file contents, I cannot provide specific details about the renovation plans, specifications, or technical requirements that would typically be included in such architectural documentation.

Due to the limited information available and potential inconsistency in the source data, I cannot confidently provide details about pricing, funding, or other specific project parameters that would normally be visible in construction drawings or renovation documentation.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

362S125-30 16" 15'-6"

600S125-30 16" 22'-11"

5/8" TYPE X GYPSUM BOARD

SOUND INSULATION, UNO

PLAN

A3

A6

WALL TYPE

STUD

DESIGNATION

SPACING

MAX. HEIGHT

(5 PSF, L/240)

FIRE RATING /

UL DESIGN

NOTES:

1. REFER TO DETAIL FOR TOP OF WALL BRACING AT ALL WALLS U.N.O.

SOUND

TRANSMISSION

(STC)

METAL STUDS

1/ G1-10

5/8" TYPE 'X' GYP BD

SOUND BATT

INSULATION

3 5/8" METAL STUDS

BATT INSULATION

FOR SOUND

EXTEND 1 STUD ABOVE

CEILING TILE EVERY

4'-0". NOTCH EXISTING

METAL CEILING TILE AS

REQ'D. NOTCH TO BE

CUT TIGHT TO STUD AS

TO NOT BE VISIBLE

WHEN GYPSUM BOARD

IS INSTALLED.

KICKER AT EACH

EXTENDED STUD,

ALTERNATE

DIRECTIONS

BLOCKING AS REQ'D

EXISTING

STRUCTURE ABOVE

EXISTING METAL

CEILING TILE

PROJECT GENERAL NOTES

A. ALL WORK SHALL CONFORM TO THE CONTRACT DOCUMENTS, WHICH INCLUDE,

BUT ARE NOT LIMITED TO, THE OWNER - CONTRACTOR AGREEMENT, THE

PROJECT MANUAL (WHICH INCLUDES GENERAL AND SUPPLEMENTARY

CONDITIONS AND SPECIFICATIONS), DRAWINGS OF ALL DISCIPLINES AND ALL

ADDENDA, MODIFICATIONS AND CLARIFICATIONS ISSUED BY THE ARCHITECT /

ENGINEER.

B. CONTRACT DOCUMENTS SHALL BE ISSUED TO ALL SUBCONTRACTORS BY THE

PRIME CONTRACTOR IN COMPLETE SETS IN ORDER TO ACHIEVE THE FULL

EXTENT AND COMPLETE COORDINATION OF ALL WORK. CONTRACTOR IS

RESPONSIBLE FOR COORDINATING AND CORRELATING QUANTITIES AND

DIMENSIONS.

C. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. NOTIFY

ARCHITECT/ENGINEER OF ANY DISCREPANCIES OR CONDITIONS REQUIRING

INFORMATION OR CLARIFICATION BEFORE PROCEEDING WITH THE WORK.

D. FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS. NOTIFY ARCHITECT /

ENGINEER OF ANY DISCREPANCIES OR CONDITIONS REQUIRING INFORMATION

OR CLARIFICATION BEFORE PROCEEDING WITH THE WORK.

E. DETAILS SHOWN ARE INTENDED TO BE INDICATIVE OF THE PROFILES AND TYPE

OF DETAILING REQUIRED THROUGHOUT THE WORK. DETAILS NOT SHOWN ARE

SIMILAR IN CHARACTER TO DETAILS SHOWN. WHERE SPECIFIC DIMENSIONS,

DETAILS OR DESIGN INTENT CANNOT BE DETERMINED, NOTIFY ARCHITECT /

ENGINEER BEFORE PROCEEDING WITH THE WORK.

F. ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE APPLIED,

INSTALLED, CONNECTED, ERECTED, CLEANED AND CONDITIONED ACCORDING TO

MANUFACTURERS' INSTRUCTIONS. IN CASE OF DISCREPANCIES BETWEEN

MANUFACTURERS' INSTRUCTIONS AND THE CONTRACT DOCUMENTS, NOTIFY

ARCHITECT / ENGINEER BEFORE PROCEEDING WITH THE WORK.

G. LARGE-SCALE, MORE SPECIFIC DETAILS TAKE PRECEDENCE OVER

SMALLER-SCALE, LESS SPECIFIC DETAILS AND INFORMATION. MORE STRINGENT

REQUIREMENTS FOR CODE, PRODUCTS AND INSTALLATION TAKE PRECEDENCE

OVER LESS STRINGENT REQUIREMENTS. NOTIFY ARCHITECT/ENGINEER OF ANY

DISCREPANCIES OR CONDITIONS REQUIRING INFORMATION OR CLARIFICATION

BEFORE PROCEEDING WITH THE WORK.

H. PROVIDE CONTINUOUS SEALANT AROUND ALL MATERIALS AT ALL INTERIOR AND

EXTERIOR WALL PENETRATIONS. REFER TO SPECIFICATIONS FOR APPROPRIATE

SEALANT.

I. ALL DISSIMILAR METALS SHALL BE EFFECTIVELY ISOLATED FROM EACH OTHER

TO AVOID GALVANIC CORROSION.

J. SEAL ALL OPENINGS IN WALLS, FLOORS, CEILINGS, AND ROOFS, AROUND DUCTS,

PIPES, VENTS, TRAPS, CONDUIT AND ALL OTHER PENETRATIONS WITH FIRE

STOPPING AS SPECIFIED AND REQUIRED BY CODES. IF FIRE STOPPING IS NOT

REQUIRED AT PENETRATIONS PER CODE, SEAL WITH CONTINUOUS SEALANT.

K. PROVIDE TEMPORARY WALLS, ENCLOSURES, DUST SHIELDS AND WALK-OFF MATS

AS REQUIRED TO SEPARATE DEMOLITION AND CONSTRUCTION FROM EXISTING

BUILDING.

L. PROVIDE BRACING AND SHORING AS REQUIRED TO PROTECT EXISTING

STRUCTURE TO REMAIN. PROVIDE SECURE AND WEATHERPROOF ENCLOSURE OF

TEMPORARY OPENINGS IN EXTERIOR WALLS. PROTECT ALL BUILDING

COMPONENTS FROM DAMAGE DURING DEMOLITION AND CONSTRUCTION.

M. RESTORE ALL EXISTING AREAS AFFECTED BY DEMOLITION AND RELATED NEW

CONSTRUCTION TO THEIR ORIGINAL CONDITION, INCLUDING BUT NOT LIMITED TO

WALLS, FLOORS, AND CEILINGS AND THEIR ASSOCIATED FINISHES.

N. PROVIDE SOLID WALL BACKING WITH METAL OR FIRE-RETARDANT WOOD

BLOCKING BEHIND DOOR HARDWARE SUCH AS WALL STOPS, BUMPERS, HOLD

OPENS, ETC. AND AT ALL ITEMS REQUIRING FASTENING THROUGH GYP BD. TO

BLOCKING

O. RENDERED IMAGES MAY NOT BE AN ACCURATE REPRESENTATION OF BUILDING

CONDITIONS, REFER TO PLANS AND DETAILS CONTAINED WITHIN FOR SCOPE OF

WORK.

SHEET INDEX

SHEET # SHEET TITLE

GENERAL

G1-10 TITLE SHEET, SHEET INDEX, PROJECT GENERAL NOTES

G1-21 CODE DATA AND CODE DATA PLAN

ARCHITECTURAL

A1-11 LEVEL 5 DEMOLITION PLAN

A1-21 LEVEL 5 FLOOR PLAN

A1-31 LEVEL 5 REFLECTED CEILING PLAN AND DETAILS

A1-41 LEVEL 5 FINISH PLAN & SCHEDULE

PLUMBING

MP0-01 DIV 21,22,23 SYMBOLS / ABBREVIATIONS

P1-11 FIFTH FLOOR PLUMBING DEMOLITION PLAN

P2-10 FOURTH FLOOR PLUMBING PLAN

P2-11 FIFTH FLOOR PLUMBING PLAN

P6-11 PLUMBING ISOMETRICS, DETAILS, SCHEDULES, AND SPECIFICATIONS

FIRE PROTECTION

FP2-11 FIFTH FLOOR FIRE PROTECTION PLAN

MECHANICAL

M1-11 FIFTH FLOOR MECHANICAL DEMOLITION PLAN

M2-11 FIFTH FLOOR MECHANICAL PLAN

M4-11 MECHANICAL DETAILS

M5-11 MECHANICAL SCHEDULES AND SPECIFICATIONS

ELECTRICAL

E1-11 LEVEL 5 ELECTRICAL DEMOLITION PLAN

E2-11 LEVEL 5 POWER AND FIRE ALARM PLAN

E2-12 LEVEL 5 POWER DEVICE DIMENSIONS

E2-21 LEVEL 5 LIGHTING PLAN

E4-10 ELECTRICAL SYMBOLS, SCHEDULES, AND DETAILS

TECHNOLOGY

T2-11 FIFTH FLOOR TECHNOLOGY PLAN

T2-21 LEVEL 5 SOUND MASKING FLOOR PLAN

T3-11 TECHNOLOGY ENLARGEMENTS AND DETAILS

T6-11 TECHNOLOGY DETAILS, RISERS, AND MATERIAL SCHEDULES

217 EAST 2ND STREET

SUITE 110

DES MOINES, IOWA 50309

PHONE: 515.243.9143

DES MOINES OFFICE

/2

/4

R E

F E

R E

N C

E S

C A

L E

SHEET

PROJECT

PROJECT NO.

FILE NAME

DRAWN BY

DESIGNED BY

ORIGINAL ISSUE DATE

CLIENT PROJECT NO.

TITLE

REVIEWED BY

PROJECT INDEX:

OWNER: PROJECT ADDRESS:

THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,

INC. AND MAY NOT BE USED, COPIED OR DUPLICATED

WITHOUT PRIOR WRITTEN CONSENT.

© 2024 I & S GROUP, INC.

MANAGING OFFICE:

1/21/2025 3:21:56 PM

G1-10

TITLE SHEET,

SHEET INDEX,

PROJECT

GENERAL NOTES

DAS CC IDALS

HOOVER

DES MOINES IOWA

KKT

KKT

01/21/2025

EMS

9426.00

24-31954

5TH FLOOR

RENOVATION

HOOVER STATE OFFICE BUILDING

1305 EAST WALNUT STREET

DES MOINES, IOWA 50319

PROJECT MANAGER: PYLAR EATON

EMAIL: PYLAR.EATON@ISGINC.COM

IOWA DEPT OF ADMINISTRATIVE

SERVICES

MICHAEL BRADBURY

1305 EAST WALNUT STREET

DES MOINES, IOWA 50319

PHONE #

FAX #

DES MOINES, IOWA

G1-10 TITLE SHEET, SHEET INDEX, PROJECT GENERAL NOTES

DAS CC IDALS HOOVER 5TH FLOOR RENOVATION

200 31954 G1-10

ISG PROJECT # 24-31954

3" = 1'-0"A

WALL TYPE A (METAL STUD PARTITION)

1/2" = 1'-0"1

TYPICAL WALL CONNECTION TO

EXISTING STRUCTURE

VICINITY MAP

DAS PROJECT #9426.00 RFP: 942600-01

CONTRACTOR

PARKING

BID ALTERNATES:

BID ALTERNATE #1

• BASE BID: NO SOUND MASKING IN WORK AREA.

• BID ALTERNATE: INSTALL SOUND MASKING IN WORK AREA.

BID ALTERNATE #2

• BASE BID: REUSE EXISTING THERMOSTATS.

• BID ALTERNATE: REPLACE THERMOSTATS AS IDENTIFIED IN DRAWINGS.

REFER TO ASSOCIATED PLANS FOR MORE INFORMATION ON EACH ALTERNATE.

PRINTED SIGNATURE

SIGNATURE DATE

LICENSE RENEWAL DATELICENSE NUMBER

SEAL

S N

E C I

W

E

LANOISSEFORP

L D

IO A

N R

E E

NI

G

E

I HEREBY CERTIFY THAT THE PORTION OF THIS

TECHNICAL SUBMISSION DESCRIBED BELOW WAS

PREPARED BY ME OR UNDER MY DIRECT SUPERVISION

AND RESPONSIBLE CHARGE. I AM A DULY LICENSED

ENGINEER UNDER THE LAWS OF THE STATE OF IOWA.

SHEETS COVERED BY THIS SEAL:

BRETT

WALKER

P28162 12/31/2026P28162

BRETT WALKER

01/21/2025

I HEREBY CERTIFY THAT THE PORTION OF THIS

TECHNICAL SUBMISSION DESCRIBED BELOW WAS

PREPARED BY ME OR UNDER MY DIRECT SUPERVISION

AND RESPONSIBLE CHARGE. I AM A DULY LICENSED

ARCHITECT UNDER THE LAWS OF THE STATE OF IOWA.

PRINTED SIGNATURE

SIGNATURE DATE

LICENSE RENEWAL DATELICENSE NUMBER

SEAL

S N

E C I

W

R T

E

C E

TI

H

C A

LANOISSEFORP

L D

IO A SHEETS COVERED BY THIS SEAL:

ERICA

SCHAEFER

07376 06/30/202607376

ERICA M. SCHAEFER

01/21/2025

PRINTED SIGNATURE

SIGNATURE DATE

LICENSE RENEWAL DATELICENSE NUMBER

SEAL

S N

E C I

W

E

LANOISSEFORP

L D

IO A

N R

E E

NI

G

E

I HEREBY CERTIFY THAT THE PORTION OF THIS

TECHNICAL SUBMISSION DESCRIBED BELOW WAS

PREPARED BY ME OR UNDER MY DIRECT SUPERVISION

AND RESPONSIBLE CHARGE. I AM A DULY LICENSED

ENGINEER UNDER THE LAWS OF THE STATE OF IOWA.

SHEETS COVERED BY THIS SEAL:

ADAM

PULS

P23206 12/31/2025P23206

ADAM W. PULS

01/21/2025

PRINTED SIGNATURE

SIGNATURE DATE

LICENSE RENEWAL DATELICENSE NUMBER

SEAL

S N

E C I

W

E

LANOISSEFORP

L D

IO A

N R

E E

NI

G

E

I HEREBY CERTIFY THAT THE PORTION OF THIS

TECHNICAL SUBMISSION DESCRIBED BELOW WAS

PREPARED BY ME OR UNDER MY DIRECT SUPERVISION

AND RESPONSIBLE CHARGE. I AM A DULY LICENSED

ENGINEER UNDER THE LAWS OF THE STATE OF IOWA.

SHEETS COVERED BY THIS SEAL:

ROYAL

STREED

P26593 12/31/2026P26593

ROYAL D. STREED

01/21/2025

G1-10

G1-21

A1-11

A1-21

A1-31

A1-41

A1-31

MP0-01 P1-11

P2-10

P2-11

P6-11

FP2-11

E1-11

E2-11

E2-12

E2-21

E4-10 T2-11

T2-21

T3-11

T6-11

REVISION SCHEDULE

DATE DESCRIPTION BY

M1-11

M2-11

M4-11

M5-11

CODE DATA PLAN KEY

EXIT

FIRE EXTINGUISHER

SEMI-RECESSED FIRE

EXTINGUISHER CABINET

FE

FEC

FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE

BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL

REQUIRED TO HAVE PROTECTED OPENINGS OR

PENETRATIONS SHALL BE EFFECTIVELY AND PERMANENTLY

IDENTIFIED WITH SIGNS OR STENCILING. SUCH

IDENTIFICATION SHALL:

1. BE LOCATED IN ACCESSIBLE CONCEALED FLOOR, FLOOR-

CEILING OR ATTIC SPACES

2. BE LOCATED WITHIN 15 FEET OF THE END OF EACH WALL

AND AT INTERVALS NOT EXCEEDING 30 FEET MEASURED

HORIZONTALLY ALONG THE WALL OR PARTITION, AND

3. INCLUDE LETTERING NOT LESS THAN 3 INCHES IN HEIGHT

WITH A MINIMUM 3/8" STROKE IN A CONTRASTING COLOR

INCORPORATING THE SUGGESTED WORDING "FIRE

AND/OR SMOKE BARRIER - PROTECT ALL OPENINGS" OR

OTHER SIMILAR WORDING.

COMMON PATH OF TRAVEL

WALL LEGEND

EXISTING CONSTRUCTION TO REMAIN

NEW CONSTRUCTION

CONTRACTOR TO VERIFY EXISTING RATED WALL

CONSTRUCTION IN FIELD AND REPORT ANY

DISCREPANCIES TO THE PROJECT ARCHITECT.

H521

STORAGE H519

STAIR

H520

ELECH522

COMM

H532

ELEC

H534

COMM

H515

WOMENS

H553

STORAGE

H509

ELEV

H511

ELEV

H503

ELEV

H505

ELEV

H507

STAIR

H563

MENS

H594

COMM

H592

ELEC

H575

FREIGHT

ELEV

H571

EQUIP

H569

STORAGE

H567

STAIR

H577

VENDING

H588

STORAGE

H572

COMM

H570

ELEC

H523

CORR

OPEN TO BELOW

H579

BREAK

ROOM

H501

ELEV

LOBBY

H513

CORRIDOR

H540

OFFICE

COS

H542

OFFICE

SEC

H544

RR

H546

CONFERENCE

H548

OFFICE

D. SEC

H550

OFFICE

REG

H552

OFFICE

REG

H554

OFFICE

CFO

H568

OFFICE

STATE VET

H574

OFFICE

ASST VET

H576

OFFICE

ASST VET

H578

OFFICE

CLIMATE

H584

OFFICE

HR

H586

CONFIDENTIAL

ROOM

H560

CONFERENCE

H562

CONFERENCE

H558

OFFICE

LEGAL

H524

COLLABORATION

H518

CONFERENCE

H516

LARGE

CONFERENCE

H512

OFFICE

S / W

H514

OFFICE

S / W

H590

OPEN

OFFICE

H561

CORRIDOR

H564

OPEN

OFFICE

H538

OPEN

OFFICE

H516B

H516A

H518

H512

H514

H

H

H

H

H

H

H544

H

H

H A

H A

H

H569

H568

H574

H576

H578

H584

H586

H545

KITCHENETTE

H573

JANITOR

H 2H545

NOT IN SCOPE

NOT IN SCOPE

NOTE: FURNITURE SHOWN FOR REFERENCE

ONLY. OWNER TO PROVIDE FURNITURE.

FE - NEW

FE - NEW

H510

OPEN

OFFICE

THIS SPACE TO BE OCCUPIED AT A

LATER DATE BY ANOTHER TENANT.

ARCHITECTURAL SCOPE OF THIS

SPACE IS UPDATING FINISHES.

SEE DEMOLITION PLAN FOR

LIMITED DEMO IN THIS AREA.

TWO EXITS REQUIRED FROM H510,

SPACED OVER 1/3 DIAGONAL OF ROOM

104'-4 " D

IA

GONAL

1/3 D

IA

GONAL =

4'-9 1/2

FEC

FE

FEC

FEC

FE

FE

FEC

41' - 0"

COMMON PATH: 69' < 75'

H510A

R1A

R1A

R1A

V E

R

IF

Y W

O

W N

E R

P L

A N

S

V E

R

IF

Y W

O

W N

E R

P L

A N

S

V E

R

IF

Y W

O

W N

E R

P L

A N

S

MOUNTING HEIGHTS AND STANDARDS

WALL-MOUNT LAVATORY

(WITH KNEE AND TOE

CLEARANCES)

DROP-IN LAVATORY (WITH

KNEE AND TOE

CLEARANCES)

MIN

8"

M

IN9

*K C

H

MAX

6" MIN

11"

KNEE

CLEARANCE

AREA

TOE

CLEARANCE

AREA

25" MAX

17" MIN

*T S

H

*T S

H

MIN

8"

M

IN9

*K C

H

MAX.

6" MIN

11"

25" MAX

17" MIN

KNEE

CLEARANCE

AREA

TOE

CLEARANCE

AREA

18 1/4" MIN.

W H

IC

H

E V

E R

I S

G

R E

A T

E R

WATER CLOSET

REAR WALL

WATER CLOSET

SIDE WALL

24" MIN 12" MIN

*WCC

*G B

H

24" MIN

42" MAX

7"-9"

M

IN

/2

M

IN

*G B

H

*V B

H

M

IN

12" MAX 42" MIN

*VBC

54" MIN

OPERABLE PARTS OF

DISPENSERS AND SANITARY

PRODUCT RECEPTACLES

SHALL BE LOCATED WITHIN

HATCHED AREA (ONLY

APPLICABLE FOR ADULT

RESTROOMS)

60" CLEAR FLOOR SPACE

*W C

S 4

M A

X

*T P

H

MIRROR

24" MIN

M

IN

S U

R F

A C

E O

F M

IR

R

O R

M

A X

T O

R E

F L E

C T

IV

E

NOTE:

35" IF NOT LOCATED

ABOVE LAVS, SINKS

OR COUNTERS

CENTER ON

LAV BELOW

SOAP

DISPENSER

PAPER

TOWEL

DISPENSER

O P

E R

A B

L E

P A

R T

T

O H

IG

H

E S

T

FIRE EXTINGUISHER

OR CABINET

T O

T O

P O

F H

A N

D L

E

OR

FIXTURE CLEARANCES

DESCRIPTION

*GBH GRAB BAR HEIGHT

*TPH TOILET TISSUE DISPENSER HEIGHT

*WCC WATER CLOSET CENTER LINE

*WCS WATER CLOSET SEAT HEIGHT

*TSH TOP OF SINK OR COUNTER HEIGHT

*KCH KNEE CLEARANCE HEIGHT

*VBH VERTICAL GRAB BAR HEIGHT

*VBC VERTICAL GRAB BAR CENTERLINE

*HDH HIGH DRINKING FOUNTAIN SPOUT HEIGHT

*LDH LOW DRINKING FOUNTAIN SPOUT HEIGHT

*DSD DRINKING FOUNTAIN SPOUT DEPTH

FIXTURE GROUPS

*URH URINAL RIM HEIGHT

ADULTS (>12 YR)

33" - 36"

18" - 48"

17" - 18"

17" - 19"

34"

27"

39" - 41"

39" - 41"

38" - 43"

36"

5"

R1

ACCESSIBLE

NA

18" - 48"

16" - 18"

17" - 19"

34"

27"

NA

NA

38" - 43"

36"

5"

STANDARD

S

17" 24"

GRAB BARS NIC. PROVIDE

BLOCKING FOR FUTURE

GRAB BARS. TYPICAL.

A

M

IN

MATERIALS KEY

WOOD

SAND

STEEL

GRAVEL

GYPSUM BOARD

PLYWOOD

CONCRETE (SECTION)

GRANULAR FILL

EARTH

CMU (SECTION)

BATT INSULATION

BRICK

RIGID INSULATION

OR SHEATHING

SYNTHETIC STUCCO

TAGS AND SYMBOLS

SECTION

INTERIOR /

EXTERIOR

ELEVATION

DETAIL CALLOUT

AREA OF DETAIL

LEVEL 1

100'-0"

ELEVATION

WINDOW TYPE

DRAWING

TITLE

SHEET NUMBER

DETAIL NUMBER

ABBREVIATIONS

SPRAY IN PLACE

INSULATION

MATERIAL TYPE

FLOOR

MATERIAL TYPE

CASEWORK

TAG

VIEW NAME

1/8" = 1'-0"

FIN#

F FIN#

AL15

CDS

W#

H# D#

MOD LINE 1

MOD LINE 2

CDS CATALOG NUMBER FROM

NORTH AMERICAN

ARCHITECTURAL WOODWORK

STANDARDS (NAAWS)

(IF "M" IS INCLUDED SEE NOTE

BELOW FOR DESCRIPTION OF

MODIFICATION)

NOMINAL DEPTH

NOMINAL HEIGHT

NOMINAL WIDTH

DESCRIPTION OF MODIFICATION

FROM CDS CATALOG

A1-11

A1-11

SECTION NUMBER

SHEET NUMBER

A1-11

ELEVATION NUMBER

SHEET NUMBER

DENOTES

ANNOTATION IS

REFERENCING

ANOTHER VIEW

NEW

CONSTRUCTION

GRIDS

EXISTING

CONSTRUCTION

GRIDS

WALL TYPE M12

KEYNOTE TAG 3

DOOR NUMBERS 101

1 1

B

A

N

/2

/4

R E

F E

R E

N C

E S

C A

L E

SHEET

PROJECT

PROJECT NO.

FILE NAME

DRAWN BY

DESIGNED BY

ORIGINAL ISSUE DATE

CLIENT PROJECT NO.

TITLE

REVIEWED BY

THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,

INC. AND MAY NOT BE USED, COPIED OR DUPLICATED

WITHOUT PRIOR WRITTEN CONSENT.

© 2024 I & S GROUP, INC.

1/21/2025 3:22:01 PM

G1-21

CODE DATA AND

CODE DATA PLAN

DAS CC IDALS

HOOVER

DES MOINES IOWA

KKT

KKT

01/21/2025

EMS

9426.00

24-31954

5TH FLOOR

RENOVATION

G1-21 CODE DATA AND CODE DATA PLAN

200 31954 G1-21

SHEET NOT VALID UNLESS THIS TEXT IS COLOR.

GENERAL CODE DATA

PROJECT DESCRIPTION:

INTERIOR RENOVATION OF EXISTING OFFICE SPACE ON FIFTH

FLOOR OF HOOVER BUILDING AT IOWA CAPITOL COMPLEX.

(GRAY SHADED AREAS ON PLAN ARE NOT IN ARCHITECTURAL

SCOPE.)

APPLICABLE CODES:

2015 INTERNATIONAL EXISTING BUILDING CODE

OCCUPANCY:

B-BUSINESS

CONSTRUCTION TYPE:

UNKNOWN

EXISTING BUILDING (1975) IS SPRINKLED 5 STORIES ABOVE

GRADE, CONCRETE PRIMARY STRUCTURAL ELEMENTS

FIRE PROTECTION SYSTEMS:

MODIFICATION OF EXISTING SPRINKLER SYSTEM

PROJECT SCOPE:

TOTAL AREA IN SCOPE: 30,106 SF

PLUMBING FIXTURES:

EXISTING TO REMAIN, NO CHANGE IN OCCUPANCY OR SPACE

USE

NOTE: ONE RESTROOM ADDED OFF PRIVATE OFFICE H542,

COMPLIES WITH IBC 1109.2 AND ICC A117.1 - 603.

FIRE SUPPRESSION NOTES

THROUGHOUT AREA OF WORK, MODIFY EXISTING AND / OR

PROVIDE A NEW NFPA 13 FIRE SUPPRESSION (SPRINKLER)

SYSTEM. THE LICENSED AUTOMATIC SPRINKLER SYSTEM

DESIGNER / INSTALLER SHALL FIELD VERIFY ALL CONDITIONS

PRIOR TO BID. THE NFPA 13 SPRINKLER SYSTEM SHALL BE

DESIGNED, INSTALLED, MODIFIED AND TESTED BY A LICENSED

AUTOMATIC SPRINKLER SYSTEM DESIGNER / INSTALLER AND

SHALL MEET ALL APPLICABLE CODE REQUIREMENTS. THE

LICENSED AUTOMATIC SPRINKLER SYSTEM DESIGNER SHALL

PROVIDE AUTOMATIC SPRINKLER SYSTEM DESIGN

DOCUMENTS AND SHALL SUBMIT THEM TO ALL APPLICABLE

JURISDICTIONS AND AUTHORITIES AND SHALL PROCURE ALL

NECESSARY PERMITS. SPRINKLER DESIGNER / INSTALLER

SHALL PAY ALL NECESSARY PERMITTING FEES.

DESIGN OF NEW / MODIFIED NFPA 13 SPRINKLER SYSTEM

SHALL BE BASED ON, BUT NOT LIMITED TO THE FOLLOWING

CRITERIA:

1. COMPLY WITH NFPA 13 AND ALL OTHER APPLICABLE

CODES.

2. MODIFY EXISTING SPRINKLER HEAD LAYOUT TO PROVIDE

ADEQUATE COVERAGE PER CODE REQUIREMENTS.

3. MODIFY EXISTING SPRINKLER HEAD AND PIPING LAYOUT

INCLUDING ALL DROPS, ARM-OVERS AND MAIN PIPES TO

AVOID RELOCATED DIFFUSERS, LIGHT FIXTURES,

MECHANICAL WORK, PLUMBING WORK, ELECTRICAL WORK,

DEMOLITION WORK, NEW CONSTRUCTION WORK AND ALL

OTHER WORK AND COMPONENTS IN THE CONTRACT.

4. COMPLETE ALL TEMPORARY AND PERMANENT WORK

NECESSARY FOR THE REMOVAL AND REPLACEMENT OF

CEILING GRIDS, INCLUDING NEW CEILING GRIDS AND GRIDS

REMOVED AND REPLACED ONLY TO COMPLETE OTHER

WORK.

5. PROVIDE PROPER COVERAGE IN CONCEALED SPACES AS

REQUIRED PER CODE.

6. WHERE INSTALLING NEW WORK ADJACENT TO EXISTING,

MATCH NEW COMPONENTS TO EXISTING COMPONENTS

WITHIN CODE LIMITATIONS.

7. ALL NEW AND RELOCATED SPRINKLER PIPING AND

COMPONENTS SHALL BE CONCEALED ABOVE CEILINGS AND

WITHIN WALLS.

8. ALL SPRINKLER HEADS TO BE INSTALLED IN ACOUSTICAL

CEILING TILE SHALL BE INSTALLED IN CENTER OF TILE.

(MODIFIED OR ADDITION TO EXISTING SPRINKLER SYSTEM)

3/32" = 1'-0"1

LEVEL 5 CODE DATA FLOOR PLAN

# POUND OR NUMBER

@ AT

ACP ACOUSTICAL CEILING PANEL

ACT ACOUSTICAL CEILING TILE

ADA AMERICANS WITH DISABILITIES ACT

ADD ADDENDUM

ADDL ADDITIONAL

ADJ ADJACENT

AFF ABOVE FINISH FLOOR

AFG ABOVE FINISHED GRADE

AHU AIR HANDLING UNIT

ALT ALTERNATE

ALUM ALUMINUM

APPROX APPROXIMATELY

ARCH ARCHITECTURAL

AWP ACOUSTICAL WALL PANEL

B BASE

BD BOARD

BL BROADLOOM CARPET

BLDG BUILDING

BO BOTTOM OF OR BY OWNER

BR BRICK

BRG BEARING

BSMT BASEMENT

C CONDUIT

CFS COLD FORMED STEEL

CG CORNER GUARD

CIP CAST IN PLACE

CJ CONTROL JOINT OR CONSTRUCTION JOINT

CL CENTERLINE

CLG CEILING

CLR CLEAR

CM CORRUGATED METAL

CMU CONCRETE MASONRY UNIT

CO CLEANOUT

CONC CONCRETE

CONF CONFERENCE

CONT CONTINUOUS

CPT CARPET

CR CHAIR RAIL

CRK CORK

CT TILE

CURT PRIVACY CURTAIN

CY CUBIC YARD

DEMO DEMOLITION

DF DRINKING FOUNTAIN

DH DOOR HOLDER (MAGNETIC)

DIA DIAMETER

DLS DIMENSIONAL LETTER SIGNAGE

EA EACH

EC ELECTRICAL CONTRACTOR

EF EXHAUST FAN

EIFS EXTERIOR INSULATION FINISH SYSTEM

ELEC ELECTRICAL

ELEV ELEVATION

EMERG EMERGENCY

ENCL ENCLOSURE

EPDM ETHYLENE PROPYLENE DIENE MONOMER

EPX EPOXY

EQ EQUAL

EQUIP EQUIPMENT

ETC ETCETERA

EWC ELECTRIC WATER COOLER

EWC ELECTRIC WATER COOLER

EX EXISTING

EXP EXPANSION, EXPOSED

EXT EXTERIOR

F&I FURNISH AND INSTALL

FA FRESH AIR

FAAP FIRE ALARM ANNUNCIATOR PANEL

FACP FIRE ALARM CONTROL PANEL

FBO FURNISHED BY OTHERS

FD FLOOR DRAIN

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FF FLOOR FINISH

FFE FINISHED FLOOR ELEVATION

FRP FIBERGLASS REINFORCED PLASTIC

FRZ FREEZER

FS FLOOR SINK

FT FOOT OR FEET

FTG FOOTING

GA GAUGE

GALV GALVANIZED

GC GENERAL CONTRACTOR

GEN GENERATOR

GFCI GROUND FAULT CIRCUIT INTERRUPT

GL GLAZING

GND GROUND

GYP GYPSUM

HD HUB DRAIN

HDG HOT DIP GALVANIZED

HDW HARDWARE

HM HOLLOW METAL

HORIZ HORIZONTAL

HSS HOLLOW STRUCTURAL SECTION

HT HEIGHT

HVAC HEATING VENTILATION AND AIR CONDITIONING

ID INSIDE DIAMETER

IG ISOLATED GROUND

IMP INSULATED METAL PANEL

INFO INFORMATION

INP IN-PLACE

INSUL INSULATION

INT INTERIOR

J JUNCTION BOX

JAN JANITOR

JBE JOIST BEARING ELEVATION

JST JOIST

KES KITCHEN EQUIPMENT SUPPLIER

kW KILOWATT

LAV LAVATORY

LB POUND

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LN LINEAR

LVT LUXURY VINYL TILE

MATL MATERIAL

MAX MAXIMUM

MB MARKER BOARD

MECH MECHANICAL

MEP MECHANICAL , ELECTRICAL, PLUMBING

MEZZ MEZZANINE

MFR MANUFACTURER

MH MANHOLE

MIN MINIMUM

MISC MISCELLANEOUS

MO MASONRY OPENING

MTD MOUNTED

MTL METAL

MULL MULLION

NA NOT APPLICABLE

NIC NOT IN CONTRACT

NTS NOT TO SCALE

OC ON CENTER

OCEW ON CENTER EACH WAY

OD OUTSIDE DIAMETER

OH OVERHEAD

OHD OVERHEAD DOOR

OL OVERALL LENGTH

OPNG OPENING

ORD OVERFLOW ROOF DRAIN

OSB ORIENTED STRAND BOARD

PC PHOTO CELL, POLISHED CONCRETE

PLAM PLASTIC LAMINATE

PLWP PLASTIC LAMINATE WALL PANEL

PNT PAINT

PNT-#E EPOXY PAINT

POLYETH POLYETHYLENE

POLYISO POLYISOCYANURATE

PRV POWER ROOF VENTILATOR

PVC POLYVINYL CHLORIDE

QT QUARRY TILE

QTZ QUARTZ

RA RETURN AIR

RB RESILIENT BASE

RBR RUBBER

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

REF REFRIGERATOR

REINF REINFORCED

REQD REQUIRED

RES RESINOUS FLOOR

REV REVISION / REVISED

RM ROOM

RO ROUGH OPENING

ROW / R/W RIGHT OF WAY

RP RESIN PANEL

RTE REFER TO ELEVATION

RTU ROOF TOP UNIT

SA SUPPLY AIR

SC SEALED CONCRETE

SF SQUARE FOOT

SIM SIMILAR

SM SURFACE MOUNTED

SPEC SPECIFICATION

SS SOLID SURFACE

SSTL STAINLESS STEEL

STD STANDARD

STN STONE

STOR STORAGE

SUSP SUSPENDED

SV SHEET VINYL

SY SQUARE YARDS

T&G TONGUE AND GROOVE

T&P TEMPERATURE AND PRESSURE

TB TACK BOARD

TBD TO BE DETERMINED

TD TRENCH DRAIN

TEC TECTUM

TEL TELEPHONE

TEMP TEMPERATURE

TER TERRAZZO

TO TOP OF

TOF TOP OF FOOTING

TOL TOP OF LEDGE

TOS TOP OF STEEL

TOW TOP OF WALL

TR TAMPER RESISTANT

TS TUBE STEEL / THRESHOLD / TRANSITION STRIP

TV TELEVISION

TYP TYPICAL

UG UNDERGROUND

UH UNIT HEATER

UNO UNLESS NOTED OTHERWISE

VCT VINYL COMPOSITE TILE

VERT VERTICAL

VEST VESTIBULE

VF VINYL FLOOR

VIF VERIFY IN FIELD

VTR VENT THROUGH ROOF

VWP VENEER WALL PANEL

W/ WITH

W/O WITHOUT

WC WATER CLOSET

WCG WALL COVERING

WD WOOD

WF WINDOW FILM

WG WALL GUARD

WH WALL HYDRANT

WHTR WATER HEATER

WP WEATHERPROOF

WT WINDOW TREATMENT

WWF WELDED WIRE FABRIC

XFMR TRANSFORMER

REVISION SCHEDULE

DATE DESCRIPTION BY

F

WALL LEGEND

EXISTING CONSTRUCTION TO REMAIN

DEMOLITION

DEMOLITION SHEET NOTES

A. EXISTING CONDITIONS SHOWN ON DRAWINGS REPRESENT

CURRENT BUILDING. IT IS THE RESPONSIBILITY OF THE

CONTRACTOR TO EXAMINE THE DRAWINGS AND FIELD

VERIFY EXISTING CONDITIONS TO DETERMINE SCOPE OF

DEMOLITION WORK REQUIRED TO COMPLETE THE

REMODELING WORK INDICATED ON THE DRAWINGS PRIOR

TO PERFORMING WORK. ADDITIONAL WORK THAT IS

REQUIRED, WAS VISIBLE, AND COULD HAVE BEEN IDENTIFIED

DURING BIDDING SHALL BE COMPLETED BY THE

RESPONSIBLE TRADE CONTRACTOR(S) AT NO ADDITIONAL

COST TO THE OWNER.

B. REPORT ANY DISCREPANCIES TO THE ARCHITECT FOR

REVIEW. WORK DONE WITHOUT RESOLUTION OF

DISCREPANCIES MUST BE REDONE AT THE REQUEST OF THE

ARCHITECT AT NO ADDITIONAL COST TO THE CONTRACT.

C. DEMOLITION OF ANY EXISTING CONSTRUCTION SHALL

INCLUDE WHAT IS NECESSARY AND REQUIRED TO

ACCOMMODATE THE REQUIREMENTS OF NEW

CONSTRUCTION.

D. ALL LOOSE FURNISHINGS (CHAIRS, TABLES, DESKS, ETC.)

SHALL BE REMOVED AND RE-INSTALLED BY THE OWNER

UNLESS NOTED OTHERWISE.

E. ALL CORING THRU EXISTING FLOORS, WALLS & CEILINGS

SHALL BE PERFORMED BY THE CONTRACTOR REQUIRING

THE SAME.

F. ALL ROOF PENETRATIONS SHALL BE PERFORMED BY THE

TRADE REQUIRING THE SAME. PATCHING & FLASHING ROOF

SHALL BE PERFORMED BY THE ROOFING CONTRACTOR.

G. VERIFY WITH OWNER FOR ITEMS TO BE SALVAGED BEFORE

STARTING DEMOLITION WORK.

H. COORDINATE DEMOLITION OF LOAD BEARING WALLS &

STRUCTURAL ELEMENTS WITH STRUCTURAL PLANS.

I. CONSTRUCT DUST PROOF PARTITIONS TO SEPARATE AREAS

OF CONSTRUCTION FROM ADJACENT OCCUPIED AREAS

OUTSIDE SCOPE OF CONSTRUCTION.

J. AT OPENINGS IN EXISTING MASONRY WALLS, REMOVE

EXISTING WALL TO NEAREST MASONRY JOINT. SEE FLOOR

PLAN FOR OPENING SIZES. SAWTOOTH INTO EXISTING JAMB.

MATCH ADJACENT FINISHES, UNLESS NOTED OTHERWISE.

K. REQUIRED MEANS OF EGRESS FROM THE BUILDING SHALL

BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION

WHEN THE BUILDING REMAINS OCCUPIED. IN THE EVENT

THAT AN EXISTING MEANS OF EGRESS CANNOT BE

MAINTAINED, THE PRIME CONTRACTOR SHALL PROVIDE AN

APPROVED TEMPORARY MEANS OF EGRESS.

L. MAINTAIN THE INTEGRITY OF ALL EXISTING RATED

ELEMENTS, FIRE SEAL ANY PENETRATIONS WITH U.L.

APPROVED ASSEMBLY.

M. CONTRACTOR IS TO VERIFY THE EXACT LOCATION OF ALL

EXISTING UTILITIES PRIOR TO DEMOLITION ACTIVITIES.

N. DO NOT INTERRUPT EXISTING UTILITIES, EXCEPT WHEN

AUTHORIZED IN WRITING BY AHJ. PROVIDE TEMPORARY

SERVICES DURING INTERRUPTIONS TO EXISTING UTILITIES,

AS ACCEPTABLE TO GOVERNING AUTHORITIES.

O. WHEN UTILITY SERVICES ARE REQUIRED TO BE REMOVED,

RELOCATED, OR ABANDONED, PROVIDE BYPASS

CONNECTIONS TO MAINTAIN CONTINUITY OF SERVICE

BEFORE PROCEEDING WITH REMOVAL.

P. WHERE EXISTING INTERIOR PARTITIONS ARE REPLACED OR

REMOVED, REMOVE MEP SYSTEMS BACK TO PANEL, OR

MECHANICAL ROOM OR FARTHEST POSSIBLE POINT

WITHOUT DISTURBING EXISTING CONSTRUCTION, REMOVE

EXISTING MECHANICAL EQUIPMENT, RELOCATE POWER PER

MEP DRAWINGS

Q. ALL WALLS IN EXISTING ROOMS IN WHICH WORK IS

OCCURRING: A) REPAIR HOLES, DEFECTS, ETC. IN EXISTING

WALLS; B) AT REPAIRS AND UNPAINTED CMU, PROVIDE

BLOCK FILL PAINT AND TWO FINISH COATS OF PAINT; C)

PROVIDE ONE FINISH COAT OF PAINT OVER EXISTING

PAINTED WALLS.

R. PROTECT ALL DEVICES AND EQUIPMENT TO REMAIN OR BE

SALVAGED. REFER TO MECHANICAL AND ELECTRICAL

DRAWINGS.

11 22 33 55 66 77 88 1010 1111 121244 99

AA

BB

CC

DD

EE

FF6

/8

/8

D2

D2

D1

D5D5

D2

D2

D2 D2

D1D1

D1

D2

D1

D1

D1 D1

D2D2D2D2

D4

D2

D2

D2

D4

D1D1

D1

D1D1

D4

D4

D4

D4

D4

D4 D4

D4

D4 D4

D4 D4

D4

D4

D5

D1

D2

D2

D1

D1

D4

D4 D4

D6

D6 D6

D6

D6

D6

D6

D6

D6

D6

D6

D6

D9 D9 D6

D6

D6

D6

D6

D9

D9

D9

D9

D9

D9

D9 D9

D9 D9D9D9

D9 D9 D9 D9

D9 D9 D9 D9 D9 D9

D9

D10

H542

OFFICE

H544

OFFICE

H546

CONF

H548

OFFICE

H550

OFFICE

H564

OPEN

OFFICE

H540

OPEN

OFFICE

H576

OPEN

OFFICE

H578

OFFICE

H560

CONF

H562

CONF

H532

ELEC

H534

COMM

H515

WOMENS

H511

ELEV

H509

ELEV

H513

CORRIDOR

H501

ELEV

LOBBY

H505

ELEV

H503

ELEV

H507

STAIR

H553

STORAGE

H561

CORRIDOR

H594

COMM

H592

ELEC

H563

MENS

H571

EQUIP

H569

STORAGE

H573

JANITOR

H575

FREIGHT

ELEV H579

BREAK

ROOM

H577

VENDING

H567

STAIR

H570

ELEC

H572

COMM

H588

STORAGE

H523

CORR

H519

STAIR

H521

STORAGE

H522

COMM

H520

ELEC

H582

OFFICE

H530

OFFICE

H532

OPEN

OFFICE

H534

CONF

D3

D3

D7

A1-11

A1-11

D12

D13

D13

D8

D8

D8

D8

COORDINATE W/ NEW WORK

33' - 7 3/4"

C O

O R

D

IN

A T

E W

N

E W

W O

R K

/8

D11

C O

O R

D

IN

A T

E W

N

E W

W O

R K

/8

COORDINATE W/ NEW WORK

6' - 3 3/4"

D8

D8

D8

REMOVE TRAY THAT

EXTENDS INTO ROOM.

ENSURE DOORS ARE

SECURED IN CLOSED

POSITION.

N

/2

/4

R E

F E

R E

N C

E S

C A

L E

SHEET

PROJECT

PROJECT NO.

FILE NAME

DRAWN BY

DESIGNED BY

ORIGINAL ISSUE DATE

CLIENT PROJECT NO.

TITLE

REVIEWED BY

THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,

INC. AND MAY NOT BE USED, COPIED OR DUPLICATED

WITHOUT PRIOR WRITTEN CONSENT.

© 2024 I & S GROUP, INC.

1/21/2025 3:22:04 PM

A1-11

LEVEL 5

DEMOLITION

PLAN

DAS CC IDALS

HOOVER

DES MOINES IOWA

KKT

KKT

01/21/2025

EMS

9426.00

24-31954

5TH FLOOR

RENOVATION

A1-11 LEVEL 5 DEMOLITION PLAN

400 31954 A1-11

KEYNOTE LEGEND

D1 REMOVE/DEMOLISH EXISTING WALL AS INDICATED. PATCH

AND REPAIR ADJACENT WALL AND CEILING TO REMAIN.

D2 REMOVE/DEMOLISH EXISTING DOOR AND FRAME.

D3 CUT HOLE IN EXISTING WALL TO INCORPORATE NEW WORK.

D4 REMOVE EXISTING FLOOR COVERING, PREP SURFACE FOR

NEW FINISH.

D5 REMOVE/DEMOLISH EXISTING WINDOW GLAZING AND FRAME.

D6 REMOVE/DEMOLISH EXISTING STONE BASE THROUGHOUT

WORK AREA (NIC). PATCH AND REPAIR WALL AND PREPARE

FOR NEW FINISHES.

D7 REMOVE WHITEBOARD. PATCH AND REPAIR WALL.

D8 REMOVE AND SALVAGE EXISTING CEILING GRID, TILES, AND

ACCESSORIES - TURN OVER TO OWNER. REFER TO

ELECTRICAL FOR EXISTING LIGHT FIXTURES.

D9 REMOVE / DEMOLISH EXISTING VINYL BASE THROUGHOUT

WORK AREA. SKIM COAT WALL AND PREPARE FOR NEW BASE.

D10 REMOVE EXISTING HOLLOW METAL FRAME AND PREPARE

OPENING FOR NEW DOOR AND FRAME.

D11 DEMOLISH PORTION OF BULKHEAD AS REQUIRED FOR NEW

OPERABLE PARTITION WALL AND POCKET INSTALLATION.

COORDINATE WITH PARTITION WALL MFR REQ'S FOR POCKET

SIZE.

D12 REMOVE TRAY THAT EXTENDS INTO H569 FROM EQUIP H571.

REFER TO H569 DEMO PHOTO ON THIS SHEET.

D13 COORDINATE WITH OWNER FOR REMOVAL OF EXISTING

WALL-MOUNTED EQUIPMENT.

3/32" = 1'-0"4

LEVEL 5 DEMOLITION PLAN

1/8" = 1'-0"2

H560 AND H562 PARTIAL REFLECTED

CEILING DEMO PLAN

1/8" = 1'-0"1

H544 AND H546 PARTIAL REFLECTED

CEILING DEMO PLAN

NOT TO SCALE3

H569 DEMO PHOTO

WALL LEGEND

EXISTING CONSTRUCTION TO REMAIN

NEW CONSTRUCTION

FLOOR PLAN SHEET NOTES

• ALL INTERIOR PARTITION WALLS SHALL BE WALL TYPE A3,

UNLESS OTHERWISE NOTED.

• PATCH AND REPAIR ALL WALLS PRIOR TO PAINTING,

INCLUDING DAMAGE FROM REMOVAL OF EXISTING

EQUIPMENT AND ACCESSORIES.

• SKIM COAT WALL WHERE RUBBER BASE WAS REMOVED

FOR SMOOTH SUBSTRATE PRIOR TO NEW BASE INSTALL.

• INTERIOR WALL DIMENSIONS ARE FROM FACE OF EXISTING

FINISH AND FACE OF STUD WALL, UNLESS NOTED

OTHERWISE.

• PAINT ALL EXPOSED METALS INCLUDING, BUT NOT LIMITED

TO COLUMNS, RISERS, STRINGERS, HANDRAILS,

GUARDRAILS, EXPOSED LINTELS AND FLOOR EDGES,

UNLESS NOTED OTHERWISE.

• INSTALL FIRE TREATED BLOCKING AS REQUIRED IN ALL

PARTITIONS TO RECEIVE COUNTERS, SHELVING, MARKER

BOARDS, TV'S, ETC.

• ALL WALL MOUNTED ITEMS TO SIT FLUSH ON A WALL

SURFACE. IN INSTANCES WHERE A WALL MOUNTED ITEM IS

TO BE INSTALLED ON TWO DIFFERENT FINISH

THICKNESSES, PROVIDE A HARDBOARD BACKER FOR THE

ITEM TO SIT FLUSH. PROVIDE SEALANT AROUND ALL EDGES

OF BACKER AND PAINT TO MATCH ADJACENT SURFACE

• REVIEW ELECTRICAL BOXES IN WALLS THROUGHOUT

WORK AREA AND INFILL ALL UNUSED BOXES. COORDINATE

WITH CM AND ELECTRICAL CONTRACTOR.

11 22 33 55 66 77 88 1010 1111 121244 99

AA

BB

CC

DD

EE

FF

11 22 33 55 66 77 88 1010 1111 121244 99

AA

BB

CC

DD

EE

FF

H521

STORAGE H519

STAIR

H520

ELEC

H522

COMM

H532

ELEC

H534

COMM

H515

WOMENS

H553

STORAGE

H509

ELEV

H511

ELEV

H503

ELEV

H505

ELEV

H507

STAIR

H563

MENS

H594

COMM

H592

ELEC

H575

FREIGHT

ELEV

H571

EQUIP

H569

STORAGE

H567

STAIR

H577

VENDING

H588

STORAGE

H572

COMM

H570

ELEC

H523

CORR

OPEN TO BELOW

H579

BREAK

ROOM

H501

ELEV

LOBBY

H513

CORRIDOR

H540

OFFICE

COS

H542

OFFICE

SEC

H544

RR

H546

CONFERENCE

H548

OFFICE

D. SEC

H550

OFFICE

REG

H552

OFFICE

REG

H554

OFFICE

CFO

H568

OFFICE

STATE VET

H574

OFFICE

ASST VET

H576

OFFICE

ASST VET

H578

OFFICE

CLIMATE

H584

OFFICE

HR

H586

CONFIDENTIAL

ROOM

H560

CONFERENCE

H562

CONFERENCE

H558

OFFICE

LEGAL

H524

COLLABORATION

H518

CONFERENCE

H516

LARGE

CONFERENCE

H512

OFFICE

S / W

H514

OFFICE

S / W

H590

OPEN

OFFICE

H561

CORRIDOR

H564

OPEN

OFFICE

H538

OPEN

OFFICE

A1-41

A3

A3

H516B

H516A

H518

H512

H514

/8

/8

H

H

H

H

H

H

H544

H

H

H A

H A

H

H569

H568

H574

H576

H578

H584

H586

A3

A3

A3

10' - 9 5/8" 23' - 8 7/8" 5' - 10 7/8" 20' - 4 7/8" 20' - 0 7/8" 11' - 1 7/8" 11' - 1 7/8" 12' - 6 7/8"

/8

/8

16' - 1 1/4"

/8

/8

/8

/8

/8

/8

11' - 1 7/8" 14' - 11 7/8" 33' - 2 7/8" 1' - 5 1/8" ±

/8

/8

3' - 6" 1' - 6"

A1-41

A3

A3

A3

A3

A3

A3

A3

A3

A3

A3

A3

A3 A3

A3

A3

A3

A3

A3

A3

A3

H545

KITCHENETTE

C L E

A R

C L

E A

R

CLEAR

15' - 4"

CLEAR

10' - 9"

CLEAR

23' - 4"

CLEAR

20' - 0"

CLEAR

19' - 8"

CLEAR

10' - 9"

CLEAR

10' - 9"

CLEAR

12' - 2"

C L E

A R

6' - 6"

CLEAR

15' - 9"

C L E

A R

C L E

A R

C L E

A R

C L E

A R

C L E

A R

C L E

A R

/8

H573

JANITOR

A1-41

C L E

A R

EQ EQ

8' - 0" 8' - 6"

VIF

20' - 10"

V

IF

V

IF

/8

7' - 3" 6' - 5"

A1-31 2 A1-31

1 1

H

H545

6 6

A3

/8

ALIGN

15' - 8 7/8"

ALIGNALIGN

C L E

A R

CLEAR

10' - 9"

CLEAR

14' - 7"

CLEAR

32' - 10"

A3

2' - 0"

2' - 0"

FURNITURE AND ELECTRICAL

IN THIS SPACE N.I.C.

A3

A3

A3

A3

18 18

A3

A3

H510

OPEN

OFFICE

"H510A

ALIGN

METAL FRAME

FRAME TYPES

METAL FRAME

2"

WIDTH

DOOR 2"

D O

O R

H E

IG

H

T

2" 3' - 0"

2"

2' - 0" 2"

5' - 6"

ALUMINUM FRAME

ALUMINUM FRAME

2" 3' - 0" 2" 3' - 10" 2" 3' - 10" 2" 3' - 10" 2" 3' - 10" 2" 3' - 10" 2"

23' - 4"

2" 3' - 0" 2" 3' - 11" 2" 3' - 11" 2" 3' - 11" 2" 3' - 11" 2"

19' - 8"

G2 G2 G2 G2 G2 G2 G2 G2 G2 G2

ALUMINUM FRAME

G2

2" 3' - 0" 2" 2' - 0" 2" 3' - 4" 2"

9' - 0"

G2 G2 G1

ALUMINUM FRAME

G2

2"3' - 0"2"2' - 0"2"4' - 4"2"

10' - 0"

G2G2G1

ALUMINUM FRAME

G2

2" 3' - 0" 2" 2' - 0" 2"2' - 11" 2" 2' - 11" 2"

11' - 8"

G2 G2 G1 G1

G2 G2 G1 G1 G1G1G1G1G1G2G2

FL

FLUSH

DOOR TYPES

NL

NARROW LITE

M A

X

6" 8"

W1

TRANSACTION

WINDOW TYPES

3' - 6"

1"x 1" ANODIZED

ALUMINUM CHANNEL

BUTT JOINT w/ CLEAR

SEALANT

G-3

1' - 6"3

OPENING w/ EASED

EXPOSED EDGES

1/4" SPEAK

HOLES IN

3 1/2" Ø

CIRCLE

N

/2

/4

R E

F E

R E

N C

E S

C A

L E

SHEET

PROJECT

PROJECT NO.

FILE NAME

DRAWN BY

DESIGNED BY

ORIGINAL ISSUE DATE

CLIENT PROJECT NO.

TITLE

REVIEWED BY

THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,

INC. AND MAY NOT BE USED, COPIED OR DUPLICATED

WITHOUT PRIOR WRITTEN CONSENT.

© 2024 I & S GROUP, INC.

1/21/2025 3:22:07 PM

A1-21

LEVEL 5 FLOOR

PLAN

DAS CC IDALS

HOOVER

DES MOINES IOWA

KKT

KKT

01/21/2025

EMS

9426.00

24-31954

5TH FLOOR

RENOVATION

A1-21 LEVEL 5 FLOOR PLAN

400 31954 A1-21

KEYNOTE LEGEND

1 PROVIDE BLOCKING IN WALL FOR MONITOR MOUNTING.

3 NEW CONFERENCE WALLS TO DECK IN ROOMS H560 / H562.

ALL OTHER WALLS TO UNDERSIDE OF EXISTING CEILING.

4 PANEL PARTITION WALL WITH INTEGRATED MARKER BOARD

EACH SIDE - 21'-2"W x 8'-6"H.

6 PATCH AND REPAIR GYPSUM BOARD FROM REMOVAL OF

STONE WALL BASE, FINISH TO MATCH EXISTING.

16 GYPSUM CONTROL JOINT EACH SIDE OF WALL ALIGNED

WITH OPERABLE PARTITION. PROVIDE BLOCKING IN WALL

PER OPERABLE PARTITION MFR REQ'S.

17 OPERABLE PARTITION WALL POCKET DEPTH AND WIDTH TO

BE COORDINATED WITH MFR REQUIREMENTS.

18 INFILL WINDOW OPENINGS WITH METAL STUD AND GYP TO

MATCH ADJACENT WALL.

20 PROVIDE BLOCKING IN WALL FOR MONITOR MOUNTING.

REMOVE GYPSUM AS REQUIRED FOR BLOCKING

INSTALLATION. PATCH WALL TO MATCH ADJACENT

SURFACES.

21 COORDINATE WITH OWNER FOR REINSTALLATION OF

WALL-MOUNTED EQUIPMENT.

22 DASHED LINE INDICATES CEILING SCOPE ON 4TH FLOOR:

REMOVE AND REINSTALL 4TH FLOOR CEILING TILES ONLY

AS REQUIRED FOR NEW WORK. ENSURE TILES ARE

INSTALLED PROPERLY AND LAYING FLAT WHEN WORK IS

COMPLETE. REFER TO PLUMBING DRAWINGS FOR

LOCATIONS OF PIPING.

3/32" = 1'-0"1

LEVEL 5 FLOOR PLAN

DOOR SCHEDULE

MARK ROOM NAME WIDTH HEIGHT

DOOR

TYPE DOOR MATERIAL

FRAME

TYPE FRAME MATERIAL

FIRE

RATING

POWER

REQUIRED

ACCESS

CONTROL

AUTO

OPERATOR

(ADA) HOLD OPEN

EGRESS

EXIT

HARDWARE

GROUP COMMENTS

H510A OPEN OFFICE 3' - 0" 7' - 0" FL HOLLOW METAL 1 HOLLOW METAL 7.0 PANIC BAR W/ LOCAL ALARM.

H512 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.

H514 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.

H516A LARGE CONFERENCE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 3.1 PASSAGE HARDWARE.

H516B LARGE CONFERENCE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 3.1 PASSAGE HARDWARE.

H518 CONFERENCE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 3.0 PASSAGE HARDWARE. FIELD VERIFY

WALL THICKNESS FOR FRAME DEPTH.

H540 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.1 SINGLE ACTION OFFICE HARDWARE.

H542 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.

H544 RR 3' - 0" 7' - 0" FL WOOD 1 HOLLOW METAL 2.0 SINGLE ACTION PRIVACY HARDWARE.

H545 KITCHENETTE 3' - 0" 7' - 0" FL WOOD 1 HOLLOW METAL 4.0 PASSAGE HARDWARE.

H546 CONFERENCE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 3.0 PASSAGE HARDWARE.

H548 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.

H550 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.

H552 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.

H554 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.

H558 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.

H560 CONFERENCE 3' - 0" 7' - 0" NL WOOD 1 HOLLOW METAL ● ● 6.1 LOCK W/ CARD READER.

H560A CONFERENCE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM ● ● 6.0 LOCK W/ CARD READER.

H562 CONFERENCE 3' - 0" 7' - 0" NL WOOD 1 HOLLOW METAL ● ● 6.0 LOCK W/ CARD READER.

H562A CONFERENCE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM ● ● 6.0 LOCK W/ CARD READER.

H568 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.

H569 STORAGE 3' - 0" 6' - 9 3/4" FL WOOD 1 HOLLOW METAL 5.0 STOREROOM HARDWARE.

FIELD VERIFY EXISTING OPENING.

H574 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.

H576 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.

H578 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.

H584 OFFICE 3' - 0" 7' - 0" FL ALUMINUM ALUMINUM 1.0 SINGLE ACTION OFFICE HARDWARE.

H586 CONFIDENTIAL ROOM 3' - 0" 7' - 0" NL WOOD 1 HOLLOW METAL 1.0 SINGLE ACTION OFFICE HARDWARE.

GLAZING SCHEDULE

MARK MATERIAL THICKNESS COMMENTS

NON-INSULATED

G-1 GLAZING UNIT 1/4"

G-2 GLAZING UNIT,

TEMPERED

1/4"

G-3 GLAZING UNIT,

TEMPERED

3/8"

DOOR SCHEDULE GENERAL NOTES:

1. CARD READER PROVIDED AND INSTALLED BY OWNER. ROUGH IN FOR CARD READER BY CONTRACTOR.

2. DOOR HARDWARE STYLE AND FINISH TO MATCH EXISTING HARDWARE TO REMAIN. COORDINATE WITH SPEC AND OWNER.

F

F F F F FF

F

F

FF F F F F

G F

I V

S V

S

V S

F

F F

F

TT

T

T

T

T

T

T

T T

T

T

TT T T T T T

T

T T

T

T

T

T

T

T TT

T

T T

T

T

T

T

T

T

T

RCP SHEET NOTES

• COORDINATE WITH MECHANICAL, PLUMBING, FIRE

PROTECTION AND ELECTRICAL FOR EXACT LOCATIONS

OF CEILING FIXTURES, DIFFUSERS, SPRINKLER HEADS,

ETC.

• REFER TO HVAC PLANS FOR THE LOCATION OF ANY AND

ALL PLENUM CEILING SPACES. ALL WALLS AND SOFFITS

CREATING THE PLENUM SHALL EXTEND TO THE

UNDERSIDE OF STRUCTURE ABOVE AND BE SEALED.

• ENSURE ALL CEILING TILES ARE LAYING FLAT PRIOR TO

PAINTING.

11 22 33 55 66 77 88 1010 1111 121244 99

AA

BB

CC

DD

EE

FF

11 22 33 55 66 77 88 1010 1111 121244 99

AA

BB

CC

DD

EE

FF

H564

OPEN

OFFICE

H538

OPEN

OFFICE

H590

OPEN

OFFICE

H524

COLLABORATION

H579

BREAK

ROOM

H512

OFFICE

H514

OFFICE

H516

LARGE

CONFERENCE

H518

CONFERENCE

H523

CORR

H568

OFFICE

H574

OFFICE

H576

OFFICE

H578

OFFICE

H584

OFFICE

H586

CONFIDENTIAL

ROOM

H554

OFFICE

H552

OFFICE

H550

OFFICE

H548

OFFICEH546

CONFERENCE

H558

OFFICE H560

CONFERENCE

H562

CONFERENCE

H542

OFFICE

H540

OFFICE

H544

RR

H561

CORRIDOR

H569

STORAGE

ACT-1

9' - 0"

ACT-1

9' - 0"

GYP BD

8' - 6"

H519

STAIR

H521

STORAGE

H515

WOMENS

H511

ELEV

H509

ELEV

H553

STORAGE

H513

CORRIDOR

H501

ELEV

LOBBY

H503

ELEV

H505

ELEV

H507

STAIR

H563

MENS

H571

EQUIP

H567

STAIR

H577

VENDING

H575

FREIGHT

ELEV

H545

KITCHENETTE

PNT-3

A1-31

PNT-3 PNT-3

PNT-3

PNT-3 PNT-3

PNT-3

PNT-3

PNT-3

PNT-3

PNT-3

PNT-3

PNT-3

PNT-3

PNT-3 PNT-3 PNT-3

PNT-3

PNT-3

PNT-3

PNT-3

PNT-3

PNT-3

PNT-3

PNT-3

PNT-3

PNT-3PNT-3

PNT-3 PNT-3 PNT-3

PNT-3

PNT-3

PNT-3

PNT-3

PNT-3

PNT-3

A1-31

GYP BD

9' - 0"

H510

OPEN

OFFICE

FOAM TAPE

.060 THICKNESS BREAK

METAL. COLOR TO MATCH

STOREFRONT/ CURTAIN

WALL

DOUBLE STICK TAPE EA. SIDE

RIGID INSULATION

WALL BELOW

5/8" GYP. BD. SEE WALL TYPES.

LIGHT GAUGE METAL STUD

SOUND ATTENUATION

INSULATION. REFER TO WALL

TYPES.

EXISTING SILL BELOW

FOAM TAPE

.060 THICKNESS BREAK

METAL. COLOR TO MATCH

STOREFRONT/ CURTAIN

WALL

DOUBLE STICK TAPE EA. SIDE

RIGID INSULATION

WALL BELOW

5/8" GYP. BD. SEE WALL TYPES.

LIGHT GAUGE METAL STUD

SOUND ATTENUATION

INSULATION. REFER TO WALL

TYPES.

EXISTING SILL BELOW

EXISTING STOREFRONT

FRAME

HANGER RODS BY

OPERABLE WALL

CONTRACTOR. FOR

SUPPORT ABOVE, REFER

TO DETAIL

5/8" GYPSUM BOARD,

TYPICAL

HANGER BRACKET

VINYL SEAL

EQ EQ

SUSPENDED

ACOUSTICAL CEILING

TILE ASSEMBLY

3 5/8" METAL

STUDS @ 16" OC

CONTINUOUS

REMOVABLE GYP BOARD

PANEL FOR ACCESS TO

HANGER RODS

REFER TO PLAN

FOLDING PANEL

PARTITION

4/ A1-31

METAL STUD BOX HEADER

SOUND ATTENUATION

BLANKET WHERE INDICATED.

3 5/8" METAL STUDS TO

UNDERSIDE OF EXISTING

CEILING, UNO

5/8" GYP. BOARD, TYPICAL

HOLLOW METAL FRAME

SEALANT ALL SIDES OF FRAME

REFER TO DOOR SCHEDULE

FOR DOOR TYPE

METAL STUD BOX HEADER

SOUND ATTENUATION

BLANKET WHERE INDICATED.

5/8" GYP. BOARD,

TYPICAL

3/8" TREATED

WOOD SHIM

TRANSOM HEAD

DOOR HEAD

SEALANT WITH BACKER

ROD EACH SIDE

ALUMINUM

STOREFRONT FRAMING

ALUMINUM DOOR, REFER

TO DOOR SCHEDULE

EXISTING CEILING

TO REMAIN, PAINT

KICKER AT EACH

EXTENDED STUD,

ALTERNATE DIRECTIONS

EXTEND 1 STUD ABOVE CEILING

TILE EVERY 4'-0". NOTCH

EXISTING METAL CEILING TILE

AS REQ'D. NOTCH TO BE CUT

TIGHT TO STUD AS TO NOT BE

VISIBLE WHEN GYPSUM BOARD

IS INSTALLED.

SEALANT (BOTH SIDES OF FRAME)

HOLLOW METAL FRAME W/

METAL STUD ANCHORS.

1/4" GLAZING, SEE SCHEDULE W/

APPLIED CONTINUOUS STOPS

METAL STUDS, SOUND

ATTENUATION INSULATION, AND

GYP BD. REFER TO WALL TYPES.

METAL STUDS, SOUND

ATTENUATION INSULATION, AND

GYP BD. REFER TO WALL TYPES.

SEALANT (BOTH

SIDES OF FRAME)

1/4" GLAZING - REFER TO SCHEDULE W/

APPLIED CONTINUOUS STOPS

METAL STUD BOX HEADER

HOLLOW METAL FRAME.

REFER TO SCHEDULE.

HOLLOW METAL FRAME

SEALANT BOTH

SIDES OF FRAME

REFER TO DOOR SCHEDULE

FOR DOOR TYPE

SOUND ATTENUATION

BLANKET WHERE INDICATED.

5/8" GYP. BOARD, TYPICAL

METAL STUDS, REFER TO

PLAN AND WALL TYPES.

ACT-1

9' - 0"

5/8" TYPE 'X'

GYP BD

SOUND BATT

INSULATION

3 5/8" METAL

STUDS

EXISTING

STRUCTURE

ABOVE

EXISTING METAL

CEILING TILE

PROVIDE

SEALANT AT

TOP OF WALL,

BOTH SIDES

1/2"

/2

/2

PARTITION ATTACHMENTS

PER MANUFACTURER

W8X18 BETWEEN CONCRETE

WEBS WHERE PARTITION

ATTACHMENTS ARE REQUIRED

(2) ASTM A325 3/4"⌀ BOLTS

GROUP A-N, TYPICAL

L4X3.5X3/84"

NOTE: FIELD VERIFY BEAM

PLACEMENTS WITH PARTITION

ATTACHMENT LOCATIONS

N

/2

/4

R E

F E

R E

N C

E S

C A

L E

SHEET

PROJECT

PROJECT NO.

FILE NAME

DRAWN BY

DESIGNED BY

ORIGINAL ISSUE DATE

CLIENT PROJECT NO.

TITLE

REVIEWED BY

THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,

INC. AND MAY NOT BE USED, COPIED OR DUPLICATED

WITHOUT PRIOR WRITTEN CONSENT.

© 2024 I & S GROUP, INC.

1/21/2025 3:22:13 PM

A1-31

LEVEL 5

REFLECTED

CEILING PLAN

AND DETAILS

DAS CC IDALS

HOOVER

DES MOINES IOWA

KKT

KKT

01/21/2025

EMS

9426.00

24-31954

5TH FLOOR

RENOVATION

A1-31 LEVEL 5 REFLECTED CEILING PLAN AND DETAILS

400 31954 A1-31

KEYNOTE LEGEND

5 NEW 24"X24" ACCESS PANEL IN CEILING. LOCATE PIPES

PRIOR TO INSTALLATION, COORDINATE FINAL ACCESS

PANEL LOCATION WITH PIPES. ALIGN ACCESS PANEL WITH

EXISTING CEILING TILE SEAMS WHERE POSSIBLE.

8 MODIFY CEILING GRID AND TILES AS REQUIRED FOR NEW

WALL INSTALLATION WITH CLEAN CUTS AND TRANSITIONS

FOR A FINISHED END PRODUCT. REUSE COMPONENTS

WHERE POSSIBLE, PROVIDE NEW COMPONENTS AS

NECESSARY.

19 ALIGN NORTH FACE OF POCKET WITH EXISTING NORTH

FACE OF BULKHEAD.

3/32" = 1'-0"8

LEVEL 5 REFLECTED CEILING PLAN

3" = 1'-0"1

INTERIOR WALL TO GLAZING

3" = 1'-0"2

INTERIOR WALL TO MULLION

1 1/2" = 1'-0"3

FOLDING PANEL PARTITION HEAD

1 1/2" = 1'-0"9

HM DOOR HEAD AT METAL STUDS

1 1/2" = 1'-0"11

ALUM HEAD AT METAL STUDS

1 1/2" = 1'-0"5

HM LITE JAMB AT METAL STUDS

1 1/2" = 1'-0"6

HM LITE HEAD AT METAL STUDS

1 1/2" = 1'-0"7

HM DOOR JAMB AT METAL STUDS

3/4" = 1'-0"10

TOP OF WALL AT CONF

ROOMS H560 & H562

1 1/2" = 1'-0"4

PARTITION SUPPORT DETAIL

C

W

B

F

ROOM #

ROOM NAME

CEILING

WALL

BASE

FLOOR

FINISHES LISTED IN ROOM

TAG APPLY TO ALL

ELEMENTS IN ROOM,

UNLESS NOTED OTHERWISE

THE FOLLOWING SYMBOL

APPLIES TO FINISHES

DIFFERENT FROM THOSE

NOTED IN ROOM TAG:

FIN#

ROOM / FINISH TAG

THE FOLLOWING SYMBOL

INDICATES: "REFER TO

ELEVATIONS" FOR

ADDITIONAL FINISH

INFORMATION

FIN#

H521

STORAGE

H519

STAIR

H520

ELEC

H522

COMM

H532

ELEC

H534

COMM

H515

WOMENS

H553

STORAGE

H509

ELEV

H511

ELEV

H503

ELEV

H505

ELEV

H507

STAIR

H563

MENS

H594

COMM

H592

ELEC

H575

FREIGHT

ELEV

H571

EQUIP

C

W

B

F

H569

STORAGE

EXIST

EXIST

B-1

SC

H567

STAIR

H577

VENDING

C

W

B

F

H588

STORAGE

PNT-3

PNT-1

EXIST

EXIST

H572

COMM

H570

ELEC

H523

CORR

H579

BREAK

ROOM

H501

ELEV

LOBBY

H513

CORRIDOR

C

W

B

F

H540

OFFICE

PNT-3

PNT-1

B-1

CPT-1

C

W

B

F

H542

OFFICE

PNT-3

PNT-1

B-1

CPT-1

C

W

B

F

H544

RR

PNT-2

PNT-1

B-1

LVT-1

C

W

B

F

H546

CONFERENCE

PNT-3

PNT-1

B-1

CPT-1

C

W

B

F

H548

OFFICE

PNT-3

PNT-1

B-1

CPT-1

C

W

B

F

H550

OFFICE

PNT-3

PNT-1

B-1

CPT-1

C

W

B

F

H552

OFFICE

PNT-3

PNT-1

B-1

CPT-1

C

W

B

F

H554

OFFICE

PNT-3

PNT-1

B-1

CPT-1

C

W

B

F

H568

OFFICE

PNT-3

PNT-1

B-1

CPT-1

C

W

B

F

H574

OFFICE

PNT-3

PNT-1

B-1

CPT-1

C

W

B

F

H576

OFFICE

PNT-3

PNT-1

B-1

CPT-1

C

W

B

F

H578

OFFICE

PNT-3

PNT-1

B-1

CPT-1

C

W

B

F

H584

OFFICE

PNT-3

PNT-1

B-1

CPT-1

C

W

B

F

H586

CONFIDENTIAL

ROOM

PNT-3

PNT-1

B-1

CPT-1

C

W

B

F

H560

CONFERENCE

PNT-3

PNT-1

B-1

CPT-1

C

W

B

F

H562

CONFERENCE

PNT-3

PNT-1

B-1

CPT-1

C

W

B

F

H558

OFFICE

PNT-3

PNT-1

B-1

CPT-1

C

W

B

F

H524

COLLABORATION

PNT-3

PNT-1/2

B-1

CPT-1

C

W

B

F

H518

CONFERENCE

PNT-3

PNT-1

B-1

CPT-1

C

W

B

F

H516

LARGE

CONFERENCE

PNT-3

PNT-1

B-1

CPT-1

C

W

B

F

H512

OFFICE

PNT-3

PNT-1

B-1

CPT-1

C

W

B

F

H514

OFFICE

PNT-3

PNT-1

B-1

CPT-1

C

W

B

F

H590

OPEN

OFFICE

PNT-3

PNT-1

B-1

CPT-1

H561

CORRIDOR

C

W

B

F

H564

OPEN

OFFICE

PNT-3

PNT-1

B-1

CPT-1

C

W

B

F

H538

OPEN

OFFICE

PNT-3

PNT-1

B-1

CPT-1

C

W

B

F

H545

KITCHENETTE

PNT-2

PNT-1

B-1

LVT-1

PNT-EX

PN

T-

PN

T-

PN

T-

PN

T-

PN

T-

PN

T-

PN

T-

PN

T-

2 PN

T-

PN

T-

PN

T-

PN

T-

PN

T-

PN

T-

PNT-2 PNT-2

PNT-2

PN

T-

PNT-2

PN

T-

PNT-2

PN

T-

PN

T-

PN

T-

PN

T-

PN

T-

PN

T-

C

W

B

F

H510

OPEN

OFFICE

PNT-3

PNT-1

B-1

CPT-1

AA

H544

A1-41

5' - 10 7/8"

H544

RR

H545

KITCHENETTE

A3

A3

A3

A1-41 6

H545

1' - 5"

FD

/8

2' - 10"

3' - 0" 2' - 6"

PLAM-1

B-1

PNT-EX

PLAM-1

A1-41

A1-41

PLAM-2

FILLER FILLER

6' - 0"

A1-41

A1-41

PNT-1

3' - 6"

W1

A1-41

PNT-EX

TPD

R1A

SD

MR1

GB3

GB2

B-1

PNT-EX

B-1

TPD

PNT-EX

R1A

GB1

GB3

1' - 6"

PLAM WRAP, REFER TO

FINISH ELEVATIONS

1/2" PLYWOOD TYPICAL

HEAVY DUTY BLIND METAL

SHELF BRACKETS AND

POSTS

1" MELAMINE TOP, DOWELED &

GLUED

1/2" MELAMINE BACK LET IN SIDES,

TOP, BOTTOM (HOT GLUE

PERIMETER)

1" ADJUSTABLE MELAMINE SHELVES

3/4" MELAMINE SIDES, DOWELED &

GLUED (PLAM FINISHED END'S AS

NOTED)

1" PLAM BOTTOM, DOWELED &

GLUED

1' - 2"

3/4" PLAM DOOR

R E

F E

R T

O E

L E

V A

T

IO

N S

PLAM COUNTERTOPS W/ 4" BACK

SPLASH. HEAVY GAUGE BACKER

SHEET

3/4" MELAMINE SUBTOP,

DOWELED & GLUED

1" ADJUSTABLE MELAMINE SHELF

1/2" MELAMINE BACK HOUSED IN

SIDES (HOT GLUED AT PERIMETER)

3/4" MELAMINE SIDES, DOWELED

& GLUED. (PLAM FE'S AS NOTED)

3/4" MELAMINE BOTTOM

DOWELED & GLUED

ELEVATIONS

REFER TO

R E

F E

R T

O E

L E

V A

T

IO

N S

/2

3/4" PLAM DRAWER AND DOOR

PULLS

BASE, REFER TO FINISH PLANS4

1 1/2"

/2

/2

M

IN

2' - 0"

M

IN

11" MIN.

8" MIN.

REFER TO ELEVATIONS FOR FINISHES

AND CTOP EDGE STYLE

WALL LINE

1 1/2" THICK PLASTIC LAMINATE

FINISHED SUPPORT PANELS

BETWEEN EACH SINK- TYP.

SECURE TO WALL. PROVIDE

METAL THREADED INSERTS

FOR REMOVABLE PANEL

COUNTERTOP W/ SINK,

REFER TO SPECS FOR SINK

TYPE

2x4 HARDWOOD

BLOCKING CONT.

3/4" THICK REMOVABLE PLASTIC

LAMINATE FACED SHROUD-

SPLIT @ SUPPORTS BETWEEN

SINKS. PROVIDE 3 VANDAL

RESISTANT HEAD SCREWS @

EACH SIDE OF PANEL

CC

3.05 New Fifth Floor

142' - 0"

1"

9 7/8"

/2

CLEAR SILICONE SEALANT

@ PERIMETER OF ALUM.

CHANNEL, BOTH SIDES

ALUMINUM CHANNEL,

TOP AND BOTTOM

3/8" CLEAR TEMPERED

GLAZING

SOLID SURFACE

TRANSACTION TOP

4" MAX

CORRIDOROFFICE

SD

PTD

B-1

PNT-EX

N

/2

/4

R E

F E

R E

N C

E S

C A

L E

SHEET

PROJECT

PROJECT NO.

FILE NAME

DRAWN BY

DESIGNED BY

ORIGINAL ISSUE DATE

CLIENT PROJECT NO.

TITLE

REVIEWED BY

THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,

INC. AND MAY NOT BE USED, COPIED OR DUPLICATED

WITHOUT PRIOR WRITTEN CONSENT.

© 2024 I & S GROUP, INC.

1/21/2025 3:22:20 PM

A1-41

LEVEL 5 FINISH

PLAN &

SCHEDULE

DAS CC IDALS

HOOVER

DES MOINES IOWA

KKT

KKT

01/21/2025

EMS

9426.00

24-31954

5TH FLOOR

RENOVATION

A1-41 LEVEL 5 FINISH PLAN & SCHEDULE

400 31954 A1-41

KEYNOTE LEGEND

2 PAINT SIDE OF DOOR FRAMES WITHIN THE NEW WORK AREA

ON EXISTING DOORS. TRANSITION COLOR AT THE DOOR

STOP SO ONLY ONE FRAME COLOR IS VISIBLE FROM EACH

SIDE.

7 PAINT BOTH SIDES OF DOOR FRAME.

10 PAINT WALL TO MATCH EXISTING.

11 CLEAN AND PAINT EXPOSED MASONRY.

12 REFRIGERATOR BY OWNER.

13 MICROWAVE BY OWNER.

14 COFFEE MAKER BY OWNER.

15 UNDER-COUNTER REFRIGERATOR BY OWNER.

INTERIOR FINISH SCHEDULE

MARK MATERIAL TYPE MANUFACTURER MODEL / SIZE COLOR ADDITIONAL INFORMATION COMMENTS

CEILING

ACT-1 ACOUSTIC CEILING

TILE

ARMSTRONG 584B HUMIGUARD PLUS

24"x24"x7/8"

TO MATCH EXISTING CORRIDOR H561 ACT

DOORS

WD-1 WOOD WHITE OAK ALPINE, AL18 MATCH EXISTING WOOD DOORS.

FLOOR

CPT-1 CARPET TILE SHAW CONTRACT DIFFUSE COLOR 24x24

ECOWORX

78721 WARM BLUE STYLE #5T478 COORDINATE PATTERN / DIRECTION WITH

OWNER. PROVIDE TRANSITIONS TO

DIFFERENT MATERIALS UNDER DOORS.

LVT-1 LUXURY VINYL TILE MOHAWK REFORESTATION 862 MARION COORDINATE PATTERN / DIRECTION WITH

OWNER. PROVIDE TRANSITIONS TO

DIFFERENT MATERIALS UNDER DOORS.

SC SEALED CONCRETE LATICRETE

INTERNATIONAL

L&M DRESS & SEAL CLEAN AND SEAL EXISTING CONCRETE

PLASTIC LAMINATE

PLAM-1 PLASTIC LAMINATE ARBORITE W449 EV RIFT NATURAL OAK MILLWORK

PLAM-2 PLASTIC LAMINATE ARBORITE P396 VL ARCTIC TUNDRA COUNTERTOPS

WALL

PNT-1 PAINT SHERWIN WILLIAMS SW7015 REPOSE GRAY WALLS & PILLARS

PNT-2 PAINT SHERWIN WILLIAMS SW6230 RAINSTORM ACCENT PAINT

PNT-3 PAINT SHERWIN WILLIAMS B42W02181 WHITE PRO INDUSTRIAL WATERBORNE

ACRYLIC DRYFALL FLAT

CEILINGS

PNT-4 PAINT SHERWIN WILLIAMS SW7019 GAUNTLET GRAY DOOR FRAMES

PNT-EX PAINT SHERWIN WILLIAMS MATCH ADJACENT

WALLS

PAINT TO INSIDE CORNERS FOR

CLEAN TRANSITION

WALLS

WALL BASE

B-1 VINYL BASE JOHNSONITE #48 GREY INSTALL ON ALL CASEWORK TOE

KICKS, U.N.O.

3/32" = 1'-0"13

LEVEL 5 FINISH PLAN

1/4" = 1'-0"1

ENLARGED RR H544 /

KITCHENETTE H545

3/8" = 1'-0"2

KITCHENETTE H545

3/8" = 1'-0"3

COLLABORATION H524

3/8" = 1'-0"4

CORRIDOR H561

3/8" = 1'-0"6

RR H544 - EAST

3/8" = 1'-0"7

RR H544 - SOUTH

EQUIPMENT SCHEDULE

MARK DESCRIPTION COMMENTS

PROVIDED

BY

INSTALLED

BY

GB1 36" HORIZONTAL GRAB BAR INSTALL BLOCKING FOR GRAB BAR.

GRAB BAR TO BE INSTALLED IN

FUTURE.

CONTRACTOR CONTRACTOR

GB2 42" HORIZONTAL GRAB BAR INSTALL BLOCKING FOR GRAB BAR.

GRAB BAR TO BE INSTALLED IN

FUTURE.

CONTRACTOR CONTRACTOR

GB3 18" VERTICAL GRAB BAR INSTALL BLOCKING FOR GRAB BAR.

GRAB BAR TO BE INSTALLED IN

FUTURE.

CONTRACTOR CONTRACTOR

MR1 Mirror 24"x36" CONTRACTOR CONTRACTOR

PTD Touchless Paper Towel Dispenser GP-59462A OWNER CONTRACTOR

SD Automated Touchless Soap Dispenser GJ-P191904 OWNER CONTRACTOR

TPD 2-Roll Side-by-Side Toilet Paper Dispenser 56784 OWNER CONTRACTOR

1 1/2" = 1'-0"8

FLOATING SHELF

1" = 1'-0"9

UPPER CABINET

1" = 1'-0"10

BASE CABINET

1" = 1'-0"11

ADA SINK CABINET DETAIL

3/4" = 1'-0"12

TRANSACTION WINDOW

EQUIPMENT SCHEDULE GENERAL NOTES:

1. COORDINATE FINAL INSTALLATION LOCATIONS WITH OWNER.

3/8" = 1'-0"5

RR H544 - NORTH

24/12

FIRE/SMOKE DAMPER

SMOKE DAMPER

FIRE DAMPER

MANUAL DAMPER

GRAVITY BACKDRAFT

DAMPER

MOTORIZED DAMPER

GALVANIZED

STEEL ELBOW

FLEX DUCT

(5'-0" MAX. LENGTH

OF ONE BRANCH) GALVANIZED STEEL

ELBOW AT DIFFUSER

CONNECTION

DIFFUSER

VOLUME

DAMPER

TAKE-OFF

CEILING

RADIATION

DAMPER

EXISTING

DUCTWORK

TO REMAIN

DEMOLISHED

DUCTWORK

BRANCH BALANCING DAMPER

DUCT SIZE

IN FREE

AREA

45 DEGREE

SHOE-TAP

TAKE-OFF

MITERED

ELBOWS

TURNING

VANES

EXHAUST OR

RETURN AIR

INLET

EXHAUST OR RETURN

AIR GRILLE

TYPICAL FLEXIBLE

DUCT CONNECTION

(BEFORE AND AFTER

EQUIPMENT)

NOTES:

• THIS DRAWING IS FOR INFORMATIONAL

PURPOSES ONLY. ITEMS SHOWN ARE NOT

NECESSARILY USED ON THIS PROJECT.

• DUCT SIZE: FIRST NUMBER INDICATES

DIMENSION OF SIDE SHOWN. THE SECOND

NUMBER INDICATES SIDE NOT SHOWN

- RECTANGULAR DUCT SIZEXX/XX

- ROUND DUCT SIZEX"Ø

- FLAT OVAL DUCT SIZEXX/XX"Ø

- CONNECT TO EXISTING

- THERMOSTAT

- TEMPERATURE SENSOR (DDC)

- HUMIDITY SENSOR

- DUCT SMOKE DETECTOR

- CARBON MONOXIDE SENSOR

- CARBON DIOXIDE SENSOR

- NITROGEN DIOXIDE SENSOR

- PRESSURE SENSOR

SYMBOL LEGEND

DUCTWORK LEGENDHVAC PIPING LEGEND

- HYDRONIC WATER SUPPLYHWS

- HYDRONIC WATER RETURNHWR

- LOW PRESSURE STEAMSTM-L#

- LOW PRESSURE CONDENSATE RETURNCD-L#

- CHILLED WATER SUPPLYCWS

- CHILLED WATER RETURNCWR

A-XX/XX

CFM

GRILLE, REGISTER, DIFFUSER TYPE.

DESIGN CFM

GRILLE, REGISTER, DIFFUSER TAG

A - Ø"

EXTERNAL

INSULATED

DUCT

LINED

DUCTWORK

UNLINED

DUCTWORK

EQUIPMENT

ROUND

SPIN-IN

TAKE-OFF

ACCESS PANEL

FOR TURNING VANES

DUCT INLET SIZE

- SUPPLY AIR DUCT UP / DOWN

- RETURN AIR DUCT UP / DOWN

- EXHAUST AIR DUCT UP / DOWN

DUCTWORK SYMBOLS

- CONDENSER WATER SUPPLYCNDS

- CONDENSER WATER RETURNCNDR

FABRIC DUCT SPIRAL DUCT

- BALL VALVE

- BUTTERFLY VALVE

- GATE VALVE

- GAS COCK

- CHECK VALVE

- IN LINE PUMP

- STRAINER

- BALANCING VALVE

- UNION

- PIPING DROP

- INLINE PIPING DROP

- PIPING RISE

- PIPE CAP

- PIPE BREAK

- GLOBE VALVE (NORMALLY CLOSED)

- RELIEF VALVE

FOS

FOR

FUEL OIL SUPPLY

FUEL OIL RETURN

DOMESTIC HOT WATER

DOMESTIC COLD WATER

VENT

DOMESTIC HOT WATER

RECIRCULATION

NATURAL GAS

SANITARY WASTE

- METER

- WALL / END CLEANOUT

- THERMOMETER

- FLOOR DRAIN

- FLOOR SINK

- WALL HYDRANT/ HOSE BIBB

REDUCED PRESSURE PRINCIPLE

BACKFLOW PREVENTER

M

NG

W

V

DCW

DHW

DHWR

FP-W

LIQUID PROPANE

GREASE VENT

GREASE WASTE

FIRE PROTECTION - WET

CONDENSATE DRAIN

COMPRESSED AIR

CD

CA

GW

GV

LP

SANITARY ACID VENT

SANITARY ACID WASTEAW

AV

ST-O STORM OVERFLOW

ST-P STORM PRIMARY

- ISOLATION VALVE

PIPING SYMBOLS

- CLEAN OUT

PLUMBING PIPING LEGEND

IFS

IFR

- IN FLOOR HEATING SUPPLY

- IN FLOOR HEATING RETURN

- GLOBE VALVE

- GATE VALVE (NORMALLY CLOSED)

- NEEDLE VALVE (NORMALLY CLOSED)

- NEEDLE VALVE

- FLEXIBLE CONNECTOR

- 2 WAY CONTROL VALVE

- 3 WAY CONTROL VALVE

RS

RL

- REFRIGERATION SUCTION

- REFRIGERATION LIQUID

T

T S

H

P

NO2

CO2

CO

SD

- INLINE PIPING RISE

FP-D FIRE PROTECTION - DRY

FP-PA FIRE PROTECTION - PRE-ACTION

PIPING TAGS

##"-XXX

NOMINAL PIPE SIZE

PIPE SYSTEM ABBREVIATION

##"-XXX (##) FIXTURE UNITS / FLOW

SHEET ANNOTATION SYMBOLS

01 - KEYNOTE

01 - REVISION NUMBER

- DETAIL NUMBER ON SHEET

- SHEET NUMBER

TYPICAL ANNOTATIONS

A.F.F. - ABOVE FINISH FLOOR

EA - EXHAUST AIR

OA - OUTSIDE AIR (UNCONDITIONED)

RA - RETURN AIR

SA - SUPPLY AIR

N.I.C. - NOT IN CONTRACT

BOB - BOTTOM OF BEAM

BOD - BOTTOM OF DUCT

BOJ - BOTTOM OF JOIST

BOP - BOTTOM OF PIPE

BOS - BOTTOM OF STEEL

CL - CENTERLINE

DN - DOWN

DIA - DIAMETER

FT - FEET

HD - HEAD

HP - HORSEPOWER

KW - KILOWATT

PH. - PHASE

GC - GENERAL CONTRACTOR

MC - MECHANICAL CONTRACTOR

PC - PLUMBING CONTRACTOR

MFR - MANUFACTURER

NC - NORMALLY CLOSED

NO - NORMALLY OPEN

OFCI - OWNER FURNISHED,

CONTRACTOR INSTALLED

OFOI - OWNER FURNISHED,

OWNER INSTALLED

PD - PRESSURE DROP (FEET)

PSIA - POUNDS PER SQUARE INCH,

ATMOSPHERIC

RPM - REVOLUTIONS PER MINUTE

BTU/H - BRITISH THERMAL

UNITS PER HOUR

CFM - CUBIC FEET PER MINUTE

ACH - AIR CHANGES PER HOUR

GPM - GALLONS PER MINUTE

MBH - THOUSANDS OF BTUs PER HOUR

A - AMPS

MCA - MINIMUM CIRCUIT AMPACITY

MOCP - MAXIMUM OVER CURRENT PROTECTION

PSIG - POUNDS PER SQUARE INCH,

GAUGE

FPM - FEET PER MINUTE

DB - DECIBELS

DDC - DIRECT DIGITAL CONTROL

ESP - EXTERNAL STATIC PRESSURE

EAT - ENTERING AIR TEMPERATURE (°F)

LAT

EWT

LWT

- LEAVING AIR TEMPERATURE (°F)

- ENTERING WATER TEMPERATURE (°F)

- LEAVING WATER TEMPERATURE (°F)

NC - NOISE CRITERIA

RH - RELATIVE HUMIDITY

BMS - BUILDING MANAGEMENT SYSTEM

FDC - FIRE DEPARTMENT CONNECTION

FLA - FULL LOAD AMPS

TOB - TOP OF BEAM

TOD - TOP OF DUCT

TOP - TOP OF PIPE

TOS - TOP OF STEEL

UP - UP

V / VOLT. - VOLTAGE

TYP. - TYPICAL

TSP - TOTAL STATIC PRESSURE

VFD - VARIABLE FREQUENCY DRIVE

VTR - VENT THROUGH ROOF

TON - TON OF COOLING (12,000 BTU/H)

- PIPE ANCHOR

- PIPE GUIDE

- STEAM TRAP

##' - ##" - SPOT ELEVATION

(BOTTOM OF ELEMENT)

DEMOLISHED

E…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .