RFB937000-02 - Bid Drawings.pdf

PDF 13 MB Posted

Attached to
DOC ISP Perimeter Fence Deterrent System Replacement
Solicitation number
RFB937000-01
Issued by
Jasper County, Fort Atkinson City, Iowa

About this file

The document is a set of bid drawings related to a Request for Bid (RFB) for the Perimeter Fence Deterrent System Replacement project at the Iowa State Penitentiary in Fort Madison, Iowa. The Iowa Department of Administrative Services is soliciting bids for this project, which involves the replacement of the existing perimeter fence deterrent system. The RFB reference number is 005-RFBCON-1007-2024, and the project is listed on the IMPACS Iowa Site. The bid submission deadline and other key dates are not provided in the document.

The bid drawings provide detailed technical information and specifications related to the perimeter fence deterrent system replacement, including item quantities, materials, and installation requirements. The document does not contain information about pricing terms, set-asides, incumbents, funding sources, or other salient commercial details.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

M A

R K

D A

T E

D

S

C R

I P

T I O

N

PROJECT NO:

DRAWN BY:

COPYRIGHT

DATE:

SHEET TITLE

101320

MAH

08/01/2024

2871 Heinz Rd. Suite B, Iowa City, IA 52240 T 319.855.4115 I F 319.351.0070 www.InnovativeEngineersInc.com

MEP ENGINEER

INNOVATIVE ENGINEERS, INC.

O U

T

F

O R

B

I D

IO

W

A D

EP

A

RT

. O

F A

D M

IN

IS

TR

A

TIV

E

SE

RV

IC

ES

C

EN

TR

A

L

PR

O C

UR

EM

EN

T

EN

TE

RP

RI

SE

S

(C

PE

HO

O V

ER

S

TA

TE

O

FF

IC

E

BU

IL

D

IN

G , L

EV

EL

E

A

ST

W A

LN

UT

D

ES

M O

IN

ES

, I A

-0

.0

DO

C

IS

P

PE

RI

M

ET

ER

FE

N C

E

DE

TE

RR

EN

T

SY

ST

EM

RE

PL

A

C

EM

EN

T

H

V E

F T

M

A D

I S

O N

I O

W

G00

COVER SHEET &

DRAWING

INDEX

PROJECT

LOCATION

DRAWING INDEX

GENERAL

G00 0 COVER SHEET AND DRAWING INDEX

ELECTRICAL & CONTROLS

E01 0 ELECTRICAL PLAN

E02 0 ENLARGED ELECTRICAL PLAN

E03 0 ELECTRICAL DETAILS

E04 0 ELECTRICAL NOTES & ONE-LINE DIAGRAM

E05 0 PROJECT PHOTOS

SHEET REV TITLE

N

IOWA STATE PENITENTIARYA

G00 NO SCALE

MOHAMMED N. ABU-HASAN

DEC. 31, 2025NO. 20081

ABUHASAN

N.

MOHAMMED

N

S

E

D

P

R

O

F

E S S

IO

N

A

L

E

N

G

I

N

E E

R

L

I C

E

I

O

W A

IOWA STATE PENITENTIARY

9370.00 DOC ISP PERIMETER FENCE

DETERRENT SYSTEM REPLACEMENT

ZONE 9

ZONE 10

ZONE 8

ZONE 7

ZONE 6

ZONE 5

ZONE 3

ZONE 4

ZONE 11

ZONE 12

ZONE 1ZONE 2

ZONE SEPARATION.

VERIFY EXACT LOCATION

IN THE FIELD (TYPICAL).

GENERAL ELECTRICAL DEMOLITION NOTES:

E.C. SHALL VERIFY THE EXISTING CONDITIONS AT THE

PROJECT SITE BEFORE SUBMITTING BID.

THE E.C. SHALL VISIT THE SITE TO VERIFY DEVICES

AND EQUIPMENT NOT SHOWN.

ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE

FOR HIS OWN DEMOLITION REMOVAL, CAPPING,

ABANDONING, DISCONNECTING OF EXISTING

ELECTRICAL EQUIPMENT AND MATERIAL. ALL

CUTTING, PATCHING, REPAIRING, REPLACEMENT

AND REFINISHING, SHALL MATCH THE EXISTING

CONSTRUCTION AS NEARLY AS POSSIBLE.

THE OWNER SHALL HAVE THE FIRST CHOICE TO

ACCEPT EXISTING DEVICES AND EQUIPMENT BEING

REMOVED AND NOT REUSED.

1.

SPECIFIC ELECTRICAL KEYED NOTES - DETAIL A :

EXISTING ZONE CONTROLLER CABINETS TO REMAIN. REFERENCE

DETAIL A/E03 FOR ADDITIONAL INFORMATION. (TYPICAL OF 6).

PROVIDE A NEW MAINTENANCE TERMINAL. GALLAGHER 6000

NETWORK CONTROLLER OR APPROVED EQUAL.

ADDITIONAL PROGRAMMING WILL BE REQUIRED BY ACCURATE

CONTROLS TO VIEW SEPARATION OF EXTERIOR AND INTERIOR FENCE

AT THE TERMINAL. COORDINATE WITH JEROME DAHLKE #

920-748-6603.

ZONE

INTERIOR

LINEAR FEET

EXTERIOR

LINEAR FEET

SALLYPORT

ELECTRICAL PLAN

SCALE 1/128" = 1' - 0"

A

E01

N

M A

R K

D A

S

C R

I P

T I O

N

PROJECT NO:

DRAWN BY:

COPYRIGHT

DATE:

SHEET TITLE

101320

MAH

08/01/2024

2871 Heinz Rd. Suite B, Iowa City, IA 52240 T 319.855.4115 I F 319.351.0070 www.InnovativeEngineersInc.com

MEP ENGINEER

INNOVATIVE ENGINEERS, INC.

O U

T

F

D

IO

W

A D

EP

A

RT

. O

F A

D M

IN

IS

TR

A

TIV

E

SE

RV

IC

ES

C

EN

TR

A

L

PR

O C

UR

EM

EN

T

EN

TE

RP

RI

SE

S

(C

PE

HO

O V

ER

S

TA

TE

O

FF

IC

E

BU

IL

D

IN

G , L

EV

EL

E

A

ST

W A

LN

UT

D

ES

M O

IN

ES

, I A

-0

.0

DO

C

IS

P

PE

RI

M

ET

ER

FE

N C

E

DE

TE

RR

EN

T

SY

ST

EM

RE

PL

A

C

EM

EN

T

E

F T

M

A D

I S

O N

I O

E01

ELECTRICAL

PLAN

A

E03

E02

FENCE ARRAY TO FENCE TO BE

CONFIGURED TO PROVIDE A

SEPARATION BETWEEN THE

INTERIOR AND EXTERIOR FENCE.

ALTERNATE-1. REFERENCE

DETAIL A/E03 FOR

ADDITIONAL INFORMATION.

THE SALLYPORT GATE IS THE ONLY ACCESS TO THE

WORK AREA BETWEEN THE FENCES AND ANY LIFTS OR

OTHER EQUIPMENT MUST FIT WITHIN THE DIMENSIONS

OF 95” WIDE BY 90” TALL

ENLARGED ELECTRICAL PLAN

A

E02

N

SCALE 1/16" = 1' - 0"

M A

R K

D A

S

C R

I P

T I O

N

PROJECT NO:

DRAWN BY:

COPYRIGHT

DATE:

SHEET TITLE

101320

MAH

08/01/2024

2871 Heinz Rd. Suite B, Iowa City, IA 52240 T 319.855.4115 I F 319.351.0070 www.InnovativeEngineersInc.com

MEP ENGINEER

INNOVATIVE ENGINEERS, INC.

O U

T

F

D

IO

W

A D

EP

A

RT

. O

F A

D M

IN

IS

TR

A

TIV

E

SE

RV

IC

ES

C

EN

TR

A

L

PR

O C

UR

EM

EN

T

EN

TE

RP

RI

SE

S

(C

PE

HO

O V

ER

S

TA

TE

O

FF

IC

E

BU

IL

D

IN

G , L

EV

EL

E

A

ST

W A

LN

UT

D

ES

M O

IN

ES

, I A

-0

.0

DO

C

IS

P

PE

RI

M

ET

ER

FE

N C

E

DE

TE

RR

EN

T

SY

ST

EM

RE

PL

A

C

EM

EN

T

E

F T

M

A D

I S

O N

I O

E02

ENLARGED

ELECTRICAL

PLAN

R K

D A

S

C R

I P

T I O

N

PROJECT NO:

DRAWN BY:

COPYRIGHT

DATE:

SHEET TITLE

101320

MAH

08/01/2024

2871 Heinz Rd. Suite B, Iowa City, IA 52240 T 319.855.4115 I F 319.351.0070 www.InnovativeEngineersInc.com

MEP ENGINEER

INNOVATIVE ENGINEERS, INC.

O U

T

F

D

IO

W

A D

EP

A

RT

. O

F A

D M

IN

IS

TR

A

TIV

E

SE

RV

IC

ES

C

EN

TR

A

L

PR

O C

UR

EM

EN

T

EN

TE

RP

RI

SE

S

(C

PE

HO

O V

ER

S

TA

TE

O

FF

IC

E

BU

IL

D

IN

G , L

EV

EL

E

A

ST

W A

LN

UT

D

ES

M O

IN

ES

, I A

-0

.0

DO

C

IS

P

PE

RI

M

ET

ER

FE

N C

E

DE

TE

RR

EN

T

SY

ST

EM

RE

PL

A

C

EM

EN

T

E

F T

M

A D

I S

O N

I O

E03

ELECTRICAL

DETAILS

EXISTING FENCE CONTROLLER CABINETS

NOT TO SCALE

E03

R K

D A

S

C R

I P

T I O

N

PROJECT NO:

DRAWN BY:

COPYRIGHT

DATE:

SHEET TITLE

101320

MAH

08/01/2024

2871 Heinz Rd. Suite B, Iowa City, IA 52240 T 319.855.4115 I F 319.351.0070 www.InnovativeEngineersInc.com

MEP ENGINEER

INNOVATIVE ENGINEERS, INC.

O U

T

F

D

IO

W

A D

EP

A

RT

. O

F A

D M

IN

IS

TR

A

TIV

E

SE

RV

IC

ES

C

EN

TR

A

L

PR

O C

UR

EM

EN

T

EN

TE

RP

RI

SE

S

(C

PE

HO

O V

ER

S

TA

TE

O

FF

IC

E

BU

IL

D

IN

G , L

EV

EL

E

A

ST

W A

LN

UT

D

ES

M O

IN

ES

, I A

-0

.0

DO

C

IS

P

PE

RI

M

ET

ER

FE

N C

E

DE

TE

RR

EN

T

SY

ST

EM

RE

PL

A

C

EM

EN

T

E

F T

M

A D

I S

O N

I O

E04

ELECTRICAL

NOTES &

ONE-LINE

FENCE ZONE CONTROLLER ONE-LINE (CONTROL WIRING DIAGRAM IS SHOWN FOR REFERENCE ONLY)

NOT TO SCALE

A

E04

Controller

#2

F1

F2

F3

R1

R2

R3

Sync.

Controller

#1

Sync.

Bottom Channel

Top Channel

Interlace Chennel

F1

F2

F3

R1

R2

R3

Interlace Chennel

Lightning Diverter Typ.

Top Channel

Interlace Chennel

Bottom Channel

Top Channel

Interlace Chennel

Interlace Chennel

Top Channel

Interlace Chennel

Terminal Strip typ.

w i r e s t o t a l w i r e s t o t a l w i r e s t o t a l w i r e s t o t a l

Controller

#2

F1

F2

R1

R2

Sync.

Controller

#2

Bottom Channel

Top Channel

Interlace Chennel

F1

F2

R1

R2

Interlace Chennel

Lightning Diverter Typ.

Top Channel

Interlace Chennel

Bottom Channel

Top Channel

Interlace Chennel

Interlace Chennel

Top Channel

Interlace Chennel

Terminal Strip typ.

w i r e s t o t a l w i r e s t o t a l w i r e s t o t a l w i r e s t o t a l

Controller

#1

F1

F2

R1

R2

Sync.

Controller

#1

F1

F2

R1

R2

Controller

#2

F1

F2

R1

R2

Sync.

Controller

#2

Bottom Channel

Top Channel

Interlace Chennel

F1

F2

R1

R2

Interlace Chennel

Lightning Diverter Typ.

Top Channel

Interlace Chennel

Bottom Channel

Top Channel

Interlace Chennel

Interlace Chennel

Top Channel

Interlace Chennel w i r e s t o t a l w i r e s t o t a l w i r e s t o t a l w i r e s t o t a l

Controller

#1

F1

F2

R1

R2

Sync.

Controller

#1

F1

F2

R1

R2

Controller

#3

F1

F2

R1

R2

Sync.

Controller

#3

F1

F2

R1

R2

R K

D A

S

C R

I P

T I O

N

PROJECT NO:

DRAWN BY:

COPYRIGHT

DATE:

SHEET TITLE

101320

MAH

08/01/2024

2871 Heinz Rd. Suite B, Iowa City, IA 52240 T 319.855.4115 I F 319.351.0070 www.InnovativeEngineersInc.com

MEP ENGINEER

INNOVATIVE ENGINEERS, INC.

O U

T

F

D

IO

W

A D

EP

A

RT

. O

F A

D M

IN

IS

TR

A

TIV

E

SE

RV

IC

ES

C

EN

TR

A

L

PR

O C

UR

EM

EN

T

EN

TE

RP

RI

SE

S

(C

PE

HO

O V

ER

S

TA

TE

O

FF

IC

E

BU

IL

D

IN

G , L

EV

EL

E

A

ST

W A

LN

UT

D

ES

M O

IN

ES

, I A

-0

.0

DO

C

IS

P

PE

RI

M

ET

ER

FE

N C

E

DE

TE

RR

EN

T

SY

ST

EM

RE

PL

A

C

EM

EN

T

E

F T

M

A D

I S

O N

I O

E05

PROJECT

PHOTOS

MISCELLANEOUS PROJECT PHOTOS OF THE ZONES, WEATHER HEADS, ZONE WIRING, AND RAZOR WIRE.

NOT TO SCALE

E05

Sheets and Views
G00 3-22-2024-G00
Re-Bid ELECT_PLAN 7-29-2024-E01
Re-Bid ELECT_PLAN 7-29-2024-E02
Re-Bid ELECT_PLAN 7-29-2024-E03
Re-Bid ELECT_PLAN 7-29-2024-E04
Re-Bid ELECT_PLAN 7-29-2024-E05

File details come from the government source that posted it. Updated .