RFB936100-01 - Addendum 2.pdf

PDF 466 KB Posted

Attached to
DOC MPCF Building 20 (MWU) Elevator Replacement
Solicitation number
RFB936100-01
Issued by
Henry County, Iowa

About this file

This is Addendum #2 to Request for Bids RFB936100-01 issued by the Iowa Department of Administrative Services for the DOC MPCF Building 20 (MWU) Elevator Replacement project (DAS#9361.00) at Mount Pleasant Correctional Facility. The addendum, dated June 20, 2024, addresses clarifications and modifications to the original bidding documents and supersedes conflicting portions of the Request for Bids. Key clarifications include confirmation that the 100% revised drawing set uploaded to Beeline and Blue represents the correct specifications, guidance on sump pump schedule requirements for pit sizing and pump alarm specifications, and revisions to electrical drawings. The addendum modifies electrical drawings E000 and E201, including revisions to the light fixture schedule description and approved equivalents, changes to disconnect types for the ACCU-1 unit from FCU-1 to 30A/2P WP F, removal of keynote E05 from the I-LINE PANELBOARD with relocation to the EXISTING PANEL, addition of light fixture type L11C to the top of the elevator shaft, and revisions to multiple keynotes. All bidders are required to acknowledge receipt of this addendum in their Request for Proposal submissions, with failure to do so subject to disqualification.

The addendum includes detailed electrical symbols, general notes, and specifications requiring compliance with the National Electrical Code, state amendments, local codes, and ADA accessibility guidelines. All materials must be new with manufacturer guarantees and listing from nationally recognized testing laboratories. The contractor assumes full responsibility for coordination with all trades, verification of field conditions, and compliance with all contract documents, with variations reported to the engineer prior to work progression. The addendum provides a comprehensive lighting fixture schedule, electrical coordination schedule, and detailed keynotes addressing specific installation requirements including circuit breaker placement, disconnect specifications, conduit sizing and routing, fire alarm connections, and camera installations for the elevator system replacement.

View the file

Other files

File Type Posted
RFB936100-01 - Addendum 2.pdf PDF
RFB936100-01 - Bid Form.pdf PDF
RFB936100-01 - Project Manual.pdf PDF
RFB936100-01 - Drawings.pdf PDF
RFB936100-01 - Notice.pdf PDF
RFB936100-01 - Addendum 1.pdf PDF
1236690-event.pdf PDF
RFB936100-01 - Notice.pdf PDF
RFB936100-01 - Bid Form.pdf PDF
RFB936100-01 - Drawings.pdf PDF
RFB936100-01 - Addendum 1.pdf PDF
RFB936100-01 - Project Manual.pdf PDF
Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ADDENDUM #2

Project Name: DOC MPCF Building 20 (MWU) Elevator Replacement

DAS#9361.00

RFB936100-01

Addendum #2

Dated: June 20, 2024

This Addendum forms a part of the Request For Bids documents. This Addendum supersedes and supplements all portions of the original Request For Bids with which it conflicts.

ACKNOWLEDGE RECEIPT OF THIS ADDENDUM IN THE REQUEST FOR PROPOSAL. FAILURE TO

DO SO MAY SUBJECT TO DISQUALIFICATION.

1. Questions:

Q: Drawings that Brian Adams has and what is downloaded from Beeline and Blue are different – which set is the right one?

A: The 100% revised set has been uploaded to Beeline and Blue and are the correct set per addendum 1

Q: It is not specified what size of pit and a manufacturer A: See sump pump schedule on drawings.

Q: Did not see a spec on what they wanted for pump alarm? Can we quote the same as we did for b,c,d elevators?

A: See sump pump schedule on drawings.

2. Changes to the Drawings:

E000 – ELECTRICAL GENERAL INFORMATION

1. REVISE description and approved equivalent information in light fixture schedule.

2. REVISE disconnect type to 30A/2P WP F for ACCU-1 in lieu of FCU-1.

E201 – ELECTRICAL NEW WORK PLANS

3. REMOVE keynote E05 from I-LINE PANELBOARD.

4. ADD keynote E05 to EXISTING PANEL.

5. ADD another light fixture type L11C to top of elevator shaft.

6. REVISE keynotes E02, E04, E05, and E13.

3. Attachments:

Drawings E000, E201

END OF ADDENDUM

R

S

FS

TS

VFD

B

L

L S

FACP

FARP

FSCP

DR

FR

E

J

WALL MOUNTED LIGHT

EMERGENCY LIGHT

EXIT SIGN

LIGHT FIXTURE ON EMERGENCY CIRCUIT

SINGLE POLE SWITCH

3-WAY SWITCH

4-WAY SWITCH

PUSH BUTTON

DUPLEX RECEPTACLE

DOUBLE DUPLEX RECEPTACLE

BRANCH PANEL WITH CLEARANCE

(SURFACE OR RECESS MOUNTED)

TRANSFORMER

DISCONNECT SWITCH

VARIABLE FREQUENCY DRIVE

RELAY

CONDUIT CONCEALED IN WALL OR OVERHEAD

CONDUIT CONCEALED BELOW FLOOR

CONDUIT TRANSITION UP

CONDUIT TRANSITION DOWN

CONDUIT STUBBED OUT

BRANCH CIRCUIT HOME RUN

VOICE/DATA OUTLET (WALL OR CEILING)

# - QUANTITY OF RJ-45 JACKS/CABLES.

ONE, UNLESS SHOWN OTHERWISE

W - DENOTES WALL PHONE

SPEAKER (WALL OR CEILING MOUNT)

KEYNOTE (SEE SCHEDULE)E#

SPRINKLER FLOW SWITCH

SPRINKLER VALVE TAMPER SWITCH

AUDIO NOTIFICATION DEVICE - CEILING MOUNTED

B = BELL

C = CHIME

H = HORN

S = SPEAKER

AUDIO NOTIFICATION DEVICE - WALL MOUNTED

B = BELL

C = CHIME

H = HORN

S = SPEAKER

VISUAL NOTIFICATION DEVICE - CEILING MOUNTED

VISUAL NOTIFICATION DEVICE - WALL MOUNTED

AUDIO/VISUAL NOTIFICATION DEVICE -

CEILING MOUNTED

B = BELL

C = CHIME

H = HORN

S = SPEAKER

AUDIO/VISUAL NOTIFICATION DEVICE -

WALL MOUNTED

B = BELL

C = CHIME

H = HORN

S = SPEAKER

FIRE ALARM CONTROL PANEL

FIRE ALARM RELAY PANEL

FIRE SUPPRESSION CONTROL PANEL

DOOR HOLDER/HOLD OPEN

SMOKE DAMPER RELEASE

FIRE ALARM SHUT DOWN RELAY

SMOKE DETECTOR

HEAT DETECTOR

FIREFIGHTER PHONE

EMERGENCY EXIT SIGN

SPECIAL RECEPTACLE

(CEILING, WALL, AND FLOOR MOUNTED)

DIRECT POWER CONNECTION -

WALL AND EQUIPMENT

JUNCTION BOX

SYMBOL DESCRIPTION

SYMBOL DESCRIPTION

SYMBOL DESCRIPTION

SYMBOL DESCRIPTION

SYMBOL DESCRIPTION

SIMPLEX RECEPTACLE

DUPLEX RECEPTACLE ON EMERGENCY CIRCUIT

DOUBLE DUPLEX RECEPTACLE ON EMERGENCY CIRCUIT

RECEPTACLE ON DROP CORD (DUPLEX SHOWN)

RECEPTACLE ON CORD REEL (DUPLEX SHOWN)

J

ENCLOSED CIRCUIT BREAKER

DOOR SIGNAL - APARTMENT UNIT

BUZZER

D

BELL

CHIME

SYMBOL DESCRIPTION

LIGHTING/CONTROLS

GENERAL

POWER

COMMUNICATION/DATA

SECURITY

FIRE ALARM

ELECTRICAL SYMBOLS LEGEND

FUSED DISCONNECT SWITCH

EXAMPLE RECEPTACLE TAG

##" - MOUNTING HEIGHT AS INDICATED.

IF OMITTED, 18" OR ABOVE COUNTER

XX - INDICATES RECEPTACLE CONFIGURATION:

XX

AC

GFI

HZ

IG

OC

USB

WP

XP

ABOVE COUNTER (COORDINATE HEIGHT)

GROUND FAULT CIRCUIT INTERRUPTER

HORIZONTALLY MOUNTED

ISOLATED GROUND

OCCUPANCY CONTROLLED

INTEGRAL USB CHARGER

WEATHERPROOF

EXPLOSION PROOF

XX

XX

FIRE ALARM - CONTINUED

MANUAL PULL STATION

ANN FIRE ALARM REMOTE ANNUNCIATOR

EMERGENCY POWER OFF

SURFACE MOUNTED RECEPTACLE, VARIES PER TYPE

MX MOTOR HORSEPOWER RATED SWITCH

F

L S

L

B

DH

S

E

J

DESCRIPTIONSYMBOL

POWER (CONTINUED)

SYMBOL DESCRIPTION

C CAMERA

1. ALL WORK SHALL BE IN CONFORMANCE WITH THE NATIONAL

ELECTRICAL CODE - LATEST EDITION ADOPTED BY THE STATE,

THE STATE AMENDMENTS, LOCAL/MUNICIPAL CODES AND

ORDINANCES, AND THE AUTHORITY HAVING JURISDICTION.

THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE

WITH THE ADAAG (AMERICANS WITH DISABILITIES ACT

ACCESSIBILITY GUIDELINES).

2. IT IS THE INTENT OF THESE DOCUMENTS TO COMPLY WITH

THE APPLICABLE CODES. WHERE DISCREPANCIES OCCUR,

NOTIFY THE ENGINEER/ARCHITECT IN WRITING FOR

INTERPRETATION. CORRECT ANY INSTALLATION THAT FAILS

TO COMPLY WITH THE CODES AND STANDARDS AT NO

ADDITIONAL COST TO THE OWNER.

3. CONTRACTOR SHALL PROVIDE ALL WORK NECESSARY

INCLUDING ALL LABOR, MATERIALS, PERMITS, TAXES, FEES,

INSPECTIONS, HARDWARE, AND COST FOR INSTALLATION FOR

A COMPLETE AND OPERATIONAL SYSTEM.

4. ALL MATERIALS FURNISHED BY THE CONTRACTOR SHALL BE

NEW, COMPLETE WITH MANUFACTURER’S GUARANTEE OR

WARRANTY AND SHALL BE LISTED BY A NATIONALLY

RECOGNIZED TESTING LABORATORY (NRTL).

5. COORDINATE ELECTRICAL INSTALLATION WITH ALL TRADES

PRIOR TO INSTALLATION. IF ELECTRICAL WORK INSTALLED

INTERFERES WITH OTHER TRADES AFTER INSTALLATION, THE

CONTRACTOR SHALL MAKE ALL NECESSARY CHANGES TO

CORRECT THE CONDITION AT NO ADDITIONAL COST TO THE

OWNER.

6. DRAWINGS ARE DIAGRAMMATIC. ALL DIMENSIONS SHOWN ARE

APPROXIMATE. CONTRACTOR SHALL VERIFY ALL FURNITURE,

MODULAR FURNITURE, AND EQUIPMENT LOCATIONS WITH

ARCHITECTURAL PLANS, ELEVATIONS AND REVIEWED SHOP

DRAWINGS. PRIOR TO MAKING THE ACTUAL ELECTRICAL

INSTALLATION THIS CONTRACTOR SHALL ADJUST

CONNECTION LOCATIONS TO ACCOMMODATE FURNITURE

AND/OR EQUIPMENT.

7. ALL ELECTRICAL PANELS WITH ANY BRANCH CIRCUIT/LOAD

REVISIONS (DEMOLITION OR NEW WORK) SHALL HAVE A NEW

TYPED UPDATED CIRCUIT DIRECTORY CARD INSTALLED INSIDE

THE DOOR OF THE ELECTRICAL PANEL. THE CONTRACTOR

SHALL VERIFY THAT ALL UNUSED CIRCUIT BREAKERS ARE

TURNED ‘OFF’ AND PROPERLY INDICATED AS ‘SPARE’ ON THE

NEW CIRCUIT DIRECTORY CARD. THE CONTRACTOR SHALL

INSTALL FILLER PLATES WHERE BREAKERS ARE REMOVED AS

PART OF THIS PROJECT OR HAVE BEEN REMOVED

PREVIOUSLY.

8. NO ENERGIZED CONDUCTORS SHALL BE EXPOSED AT

ANYTIME EXCEPT WHEN THE IMMEDIATE AREA IS UNDER THE

SUPERVISION OF A QUALIFIED ELECTRICIAN.

9. WHERE CONDUIT IS SURFACE MOUNTED TO A WALL AND RUN

VERTICALLY DOWN TO A SWITCH/OUTLET BOX, UTILIZE 1-HOLE

OR 2-HOLE CONDUIT STRAPS.

10. REFER TO THE ARCHITECTURAL DRAWINGS FOR LOCATIONS

OF BUILDING EXPANSION JOINTS. ALL CONDUITS CROSSING

EXPANSION JOINTS SHALL BE INSTALLED WITH EXPANSION

FITTINGS, UNLESS THE CONDUIT IS BELOW SLAB IN THE

COMPACTED GRANULAR FILL. EXPANSION FITTINGS SHALL BE

INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL

CODE, AND MANUFACTURE'S WRITTEN RECOMMENDATIONS.

11. PENETRATIONS THROUGH FIRE RATED WALLS BY DIVISION 26

CONTRACTOR SHALL BE SEALED WITH APPROPRIATE FIRE

PROOFING MATERIAL TO RESTORE FIRE RATING. REFER TO

ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS.

12. THE CONTRACTOR SHALL KEEP THE WORK AREA CLEAN OF

ALL DEBRIS ON A DAILY BASIS. ALL NEW MATERIALS AWAITING

INSTALLATION SHALL BE KEPT IN AREAS DESIGNATED BY THE

OWNER.

13. THESE DRAWINGS SHALL NOT BE SCALED TO OBTAIN

DIMENSIONS. REFER TO DIMENSIONED ARCHITECTURAL

FLOOR PLANS. IF THE DIMENSIONS CANNOT BE DETERMINED

BY THE INFORMATION GIVEN, CONTRACTOR SHALL CONTACT

THE ENGINEER FOR ADDITIONAL INFORMATION.

14. PERIODIC SITE OBSERVATION BY THE ENGINEER IS SOLELY

FOR THE PURPOSE OF DETERMINING IF THE WORK OF THE

CONTRACTOR IS PROCEEDING IN ACCORDANCE WITH THE

CONTRACT DOCUMENTS. THIS LIMITED SITE OBSERVATION

SHOULD NOT BE CONSTRUED AS EXHAUSTIVE OR

CONTINUOUS TO CHECK THE QUALITY OR QUANTITY OF THE

WORK, BUT RATHER PERIODIC IN AN EFFORT TO GUARD THE

OWNER AGAINST DEFECTS OR DEFICIENCIES IN THE WORK OF

THE CONTRACTOR.

15. THE INFORMATION CONTAINED ON THE ELECTRICAL

DRAWINGS IS IN ITSELF INCOMPLETE AND VOID UNLESS USED

IN CONJUNCTION WITH ALL OTHER DISCIPLINE DRAWINGS,

THE SPECIFICATIONS, TRADE PRACTICES, OR APPLICABLE

STANDARDS, CODES, ETC., AND SHALL BE CONSIDERED THE

CONTRACT DOCUMENTS AND WITH ALL THEREIN BY

REFERENCE, WHICH THE CONTRACTOR CERTIFIES

KNOWLEDGE OF BY SIGNING THE CONTRACT.

16. CONTRACTOR IS TO ASSUME FULL RESPONSIBILITY,

UNRELIEVED BY REVIEW OF SHOP DRAWINGS OR PERIODIC

OBSERVATION OF CONSTRUCTION, FOR COMPLIANCE WITH

THE CONTRACT DOCUMENTS, FOR DIMENSIONS TO BE

CONFIRMED AND CORRELATED ON THE JOB SITE AND

BETWEEN INDIVIDUAL DRAWINGS OR SETS OF DRAWINGS FOR

FABRICATION PROCESSES AND CONSTRUCTION TECHNIQUES

(INCLUDING EXCAVATION, SHORING, SCAFFOLDING, BRACING,

ERECTION, FORM WORK, ETC.), FOR COORDINATION OF THE

VARIOUS TRADES, AND FOR SAFE CONDITIONS ON THE JOB

SITE. VARIATIONS IN FIELD CONDITIONS RELATIVE TO THE

CONTRACT DOCUMENTS SHALL BE REPORTED TO THE

ENGINEER AS SOON AS THEY ARE FOUND. WORK SHALL NOT

PROGRESS UNTIL WRITTEN PERMISSION FROM THE ENGINEER

IS OBTAINED.

ELECTRICAL

A P

P R

O V

E D

B Y

D R

A W

N B

Y

IS

S

U E

D F

O R

IS

S

U E

D A

T E

P R

O J E

C T

N U

M B

E R

F

IE

L D

B O

O K

W

E S

T O

W N

P A

R K

W A

Y S

U

IT

E

W E

S T

D E

S M

O

IN

E S

IA

.2

.8

S

H

IV

E -H

A T

T E

R Y

.C O

M

BA D E

FC G

H

BA D E FC G H

Autodesk Revit 2023Autodesk Revit 2023

/1

/2

:2 :2

P

M

A u to d e s k D o c s /2

I A

D A

S

D O

C M

P C

F B ld g

E le v a to r R e p /2

-M

E P

-R .r v t

E L E

C T

R

IC

A L

G E

N E

R A

L

IN

F O

R M

A T

IO

N

B

ID

D

IN

G

F ie ld B o o k

E S

B F

G

/2

/2

E000

IA

D

A S

D

O C

M P

C F

B ld g

E le v a to r

R e p

Io w a D e p a rt m e n t o f

A d m in is tr a ti v e S e rv ic e s

C L

IE

N T

P R

O J E

C T

N U

M B

E R

D

A S

.0

E

W a s h in g to n S t, M t P le a s a n t, I A

1.

2.

CONNECT TO UNSWITCHED PORTION OF LIGHTING CIRCUIT.

PROVIDE WITH INTEGRAL OCCUPANCY AND DAYLIGHTING WIRELESS SENSOR.

SCHEDULE NOTES:

A.

B.

C.

D.

WHERE "OR APPROVED EQUIVALENT" IS LISTED IN THE MANUFACTURER COLUMN, FIXTURES MUST BE SUBMITTED AS A SUBSTITUTION FOR APPROVAL PRIOR TO BID SUBMISSION.

LISTED LUMENS ARE DELIVERED LUMENS. PROVIDE FIXTURE WITHIN +/- 5% OF LISTED LUMENS.

LIGHTING PRODUCTS SHALL BE PROVIDED THROUGH THE AUTHORIZED LIGHTING MANUFACTURER'S REPRESENTATIVE RESIDING WITHIN PROJECT LOCATION.

SUBMITTALS SHALL BE PRODUCED AND SUBMITTED BY LOCAL AUTHORIZED LIGHTING MANUFACTURER'S REPRESENTATIVE. LETTERHEAD SHALL CONTAIN REPRESENTATIVES' CONTACT INFORMATION, PROJECT NAME, AND PROJECT LOCATION.

GENERAL NOTES:

LED DRIVER TYPES: STND = STANDARD DRIVER, DIM10 = 0-10V 10% DIMMING, DIM1 = 0-10V 1% DIMMING, DIMD = 0-10V DIM TO DARK, STEP = STEP DIMMING, NOND = NON-DIMMING, DALI = DIGITAL ADDRESSABLE LIGHTING INTERFACE, DMX = DIGITAL MULTIPLEX, LUTR = LUTRON HI-LUME

POE = POWER OVER ETHERNET, SDIM = STEP DIMMING

MOUNTING STYLES (MTG): RE-A = RECESSED (ACT), RE-G = RECESSED (GYP), RE-W = RECESSED (WALL), CL = CEILING SURFACE, PW = PERIMETER WALL, SP = SUSPENDED (AIR-CRAFT CABLE), ST = STEM, WL = WALL, WL-H = WALL HORIZONTAL, WL-V = WALL VERTICAL, UNV = UNIVERSAL, POLE = POLE, UC =

UNDER CABINET, TR = TRACK, GND = GROUND

CATALOG NUMBER SHALL NOT BE CONSIDERED COMPLETE AND MATERIAL SHALL NOT BE ORDERED BY MANUFACTURER AND CATALOG NUMBER ONLY. THE DESCRIPTION AND THE SPECIFICATIONS SHALL BE COORDINATED WITH THE CATALOG NUMBER TO DETERMINE THE EXACT MATERIAL AND ACCESSORIES TO BE ORDERED. THE FIRST MANUFACTURER LISTED IS THE BASIS FOR DESIGN. ALL LAMPS/LIGHT SOURCES FOR THIS PROJECT SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. ALL LIGHT FIXTURES SHALL BE PROVIDED WITH INTEGRAL DISCONNECT(S) FACTORY INSTALLED IN ACCORDANCE WITH NEC. REFER TO SPECIFICATIONS FOR SHOP DRAWING SUBMITTAL REQUIREMENTS AND ADDITIONAL INFORMATION.

LIGHTING FIXTURE SCHEDULE

TYPE DESCRIPTION LENS-LOUVER MTG LIGHTING OUTPUT/CCT DRIVER VOLT WATT BASIS OF DESIGN APPROVED EQUIVALENT NOTES

L11C 5" X 4" X 4' LED LENSED WALL MOUNT FIXTURE, POLYCARBONATE HOUSING,

SWITCHABLE LUMENS, SWITCHABLE CCT

FROSTED POLYCARBONATE LENS WL LED, 4000 LUMENS, 4000K STND 120 42 LITHONIA CSVT ILP VVT4, METALUX 4VT3-SL3C3

L11D 5" X 4" X 4' LED LENSED CEILING MOUNT FIXTURE, POLYCARBONATE

HOUSING, SWITCHABLE LUMENS, SWITCHABLE CCT

FROSTED POLYCARBONATE LENS CL LED, 4000 LUMENS, 4000K STND 120 42 LITHONIA CSVT ILP VVT4, METALUX 4VT3-SL3C3

2. --.

1. POWERED THROUGH OUTDOOR UNIT ACCU-1.

REMARKS:

MOCP SIZES SHOWN BELOW ARE FOR BIDDING PURPOSES ONLY. VERIFY

MOCP WITH EQUIPMENT NAME PLATE DATA PRIOR TO ORDERING

EQUIPMENT.

MINIMUM WIRE SIZE SHALL BE #12 AWG AND MINIMUM CONDUIT SIZE SHALL

BE 3/4".

INCLUDE A SEPARATE, GREEN, CONDUCTOR IN ALL FEEDER AND BRANCH

CIRCUIT CONDUITS.

FLA - FULL LOAD AMPS

MCA - MIN. CIRCUIT AMPS

C/B - CIRCUIT BREAKER

VFD - VARIABLE FREQUENCY

DRIVE

WP - WEATHERPROOF

SPSW - SINGLE POLE SWITCH

DPST - DOUBLE POLE SINGLE

THROW SWITCH

F - FUSED

NF - NON-FUSED

MMS - MANUAL MOTOR STARTER

PWE - PROVIDED WITH EQUIPMENT

MAG - MAGNETIC STARTER

REC - RECEPTACLE

GENERAL NOTES: ABBREVIATIONS:

ELECTRICAL AND MECHANICAL COORDINATION SCHEDULE

PLAN MARK VOLTAGE PHASE FLA MCA MOCP HP WATTAGE KVA

CONDUIT AND WIRE

SIZE DISCONNECT TYPE REMARKS

ACCU-1 208 V 1 13.6 A 17 A 25 A - 2,828.8 W 2.8 W -- 30A/2P WP F --

FCU-1 208 V 1 0.5 A 0.6 A 0 A - 104 W 0.1 W -- --- 1

SP-1 120 V 1 9.8 A 12.3 A 0 A 1/2 1,180.8 W 1.2 W -- REC --

A D

D

/2 /2

A

D D

E N

D U

M

ADD

ADD

FACP

C

FR

SERVER ROOM

L11C 48"

48"

ELEVATOR

A

E02

L11C

E07

G6

E201

E09 E10

EXISTING

PANEL

E05

L11C

ELEVATOR

A

E01

E02

E07

G6

E201

E13

I-LINE

PANELBOARD

L11C

ELEVATOR

A

EXISTING SIEMENS

FIRE ALARM

CONTROL PANEL

E02

E07

G6

E201

L11C

ELEVATOR

A

E03

E02

E07

E08

G6

E201

ACCU-1

FCU-1

ELEVATOR

PENTHOUSE

A&B

E04

E06

G6

E201

E07

E11

E12

L11D E02

100' - 0"

FIRST FLOOR

100' - 0"

FIRST FLOOR

111' - 0"

SECOND FLOOR

111' - 0"

SECOND FLOOR

133' - 10"

ROOF

133' - 10"

ROOF

122' - 0"

THIRD FLOOR

122' - 0"

THIRD FLOOR

90' - 8"

BASEMENT

90' - 8"

BASEMENT

146' - 6"

PENTHOUSE ROOF

146' - 6"

PENTHOUSE ROOF

L11C L11C

L11C

L11C

L11C

L11D

A P

P R

O V

E D

B Y

D R

A W

N B

Y

IS

S

U E

D F

O R

IS

S

U E

D A

T E

P R

O J E

C T

N U

M B

E R

F

IE

L D

B O

O K

W

E S

T O

W N

P A

R K

W A

Y S

U

IT

E

W E

S T

D E

S M

O

IN

E S

IA

.2

.8

S

H

IV

E -H

A T

T E

R Y

.C O

M

BA D E

FC G

H

BA D E FC G H

Autodesk Revit 2023Autodesk Revit 2023

/1

/2

:1 :0

P

M

A u to d e s k D o c s /2

I A

D A

S

D O

C M

P C

F B ld g

E le v a to r R e p /2

-M

E P

-R .r v t

E L E

C T

R

IC

A L N

E W

W O

R K

P L A

N S

B

ID

D

IN

G

F ie ld B o o k

E S

B F

G

/2

/2

E201

IA

D

A S

D

O C

M P

C F

B ld g

E le v a to r

R e p

Io w a D e p a rt m e n t o f

A d m in is tr a ti v e S e rv ic e s

C L

IE

N T

P R

O J E

C T

N U

M B

E R

D

A S

.0

E

W a s h in g to n S t, M t P le a s a n t, I A

N

01/8" = 1'-0"A3

BASEMENT ELECTRICAL PLAN

12'

N

01/8" = 1'-0"A5

FIRST FLOOR ELECTRICAL PLAN

N

01/8" = 1'-0"E3

SECOND FLOOR ELECTRICAL PLAN

12'

N

01/8" = 1'-0"E4

THIRD FLOOR ELECTRICAL PLAN

12'

N

01/8" = 1'-0"E6

ROOF POWER PLAN

12'

KEYNOTES

KEY NOTE

E01 PROVIDE AND INSTALL A 110A/3P SHUNT-TRIP

CIRCUIT BREAKER IN EXISTING SQUARE D I-LINE

PANELBOARD FOR NEW ELEVATOR. PROVIDE AND

INSTALL 3#3, #6 GROUND IN 1-1/4" CONDUIT.

E02 CONNECT NEW LIGHT FIXTURES TO SPARE CIRCUIT

BREAKER IN EXISTING PANEL LOCATED IN THE

BASEMENT.

E03 ROUTE (2) CAT 6 DATA CABLES TO ELEVATOR

LOCATION FROM EXISTING SERVER ROOM LOCATION.

COORDINATE EXACT CONNECTION LOCATION WITH

ELEVATOR MANUFACTURER.

E04 PROVIDE AND INSTALL NEW 200A/3P DISCONNECT

WITH 110A FUSES FOR NEW ELEVATOR. PROVIDE AND

INSTALL A 30A DISCONNECT WITH 20A FUSE FOR

ELEVATOR CAB LIGHTING.

E05 PROVIDE AND INSTALL NEW 25A/2P CIRCUIT BREAKER

IN EXISTING PANEL FOR NEW PENTHOUSE

CONDENSING UNIT. PROVIDE AND INSTALL 2#10, #10

GROUND IN 3/4" CONDUIT. CONDUIT FROM PANEL TO

CONDENSING UNIT SHALL NOT BE ROUTED THROUGH

ELEVATOR SHAFT.

E06 INDOOR UNIT IS POWERED BY OUTDOOR UNIT.

E07 INSTALL OWNER SUPPLIED HEAT DETECTOR TO BE

USED DURING CONSTRUCTION. ONCE PROJECT IS

FINISHED, INSTALL SMOKE DETECTOR AS SHOWN.

E08 PROVIDE AND INSTALL 1" CONDUIT AND CAT6 CABLE

FROM CAMERA HEAD END IN SERVER ROOM TO

ELEVATOR EQUIPMENT ROOM FOR ELEVATOR CAB

CAMERA. COORDINATE EXACT LOCATION WITH

OWNER.

E09 CONNECT TO EXISTING RECEPTACLE CIRCUIT IN

ELEVATOR SHAFT.

E10 RECEPTACLE FOR SUMP PUMP CONTROL PANEL.

CONNECT TO SPARE CIRCUIT IN EXISTING PANEL

ACROSS THE CORRIDOR.

E11 CONNECT FIRE ALARM RELAY TO ELEVATOR

CONTROLLER, SEE SPECIFICATION FOR MORE

INFORMATION.

E12 PROVIDE FIRE ALARM CONNECTION TO ELEVATOR

FOR RECALL FUNCTION.

E13 PROVIDE AND INSTALL #4 GROUND WIRE FROM I-LINE

PANELBOARD TO UPSTREAM MAIN SWITCHBOARD

LOCATED APPROXIMATELY 50FT DOWN THE

CORRIDOR. COORDINATE LOCATION OF MAIN

PANELBOARD WITH OWNER.

01/4" = 1'-0"G6

ELEVATOR SHAFT SECTION VIEW

6'

A D

D

/2 /2

A

D D

E N

D U

M

ADD

ADD

ADD

ADD

ADD

ADD

ADD