RFB 2024-08-09 Addendum 02 Soda Springs Park Playground.pdf

PDF 3 MB Posted

Attached to
RFB 2024-014 Manitou Springs Soda Springs Park Playground Improvements Construct
Solicitation number
RFB 2024-014
Issued by
El Paso County, Manzanola Town, Colorado

About this file

This document is Addendum 02 for the Soda Springs Park Playground Improvements project, issued by the City of Manitou Springs on August 28, 2024. The addendum provides updates and clarifications for the bid documents related to playground renovation, including new play equipment, grading, drainage, steps, handrails, concrete and crusher fines paving, decorative metal fencing, site furnishings, planting, and irrigation. The addendum incorporates responses to bidder questions and includes irrigation as-built drawings from phase 1, with no revisions to drawing sheets. Contractors are instructed to acknowledge receipt of this addendum on their bid form, and the addendum will be attached to the original Contract Documents dated March 22, 2024.

The document includes critical information for potential bidders, such as clarifications on permits (a Flood Plain Development Permit and Grading/Erosion Control Permit are required), utility locations, and project specifics. Key details from the bidder questions reveal that the contractor will be responsible for street closures and traffic control, playground equipment use zones have been calculated, and the city will contract third-party testing for concrete, form inspections, and compaction. The warranty period begins upon Substantial Completion, and the project includes specifics about existing site conditions, such as a concrete footer for the Mosaic Wall. The city has also clarified that the previously mentioned year of mowing maintenance has been removed, with only a 12-month warranty for planting and sod remaining.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SODA SPRINGS PARK PLAYGROUND PLAYGROUND IMPROVEMENTS

HCM Job No. 223108.00

ADDENDUM 02 009113.02 - 1

1. DOCUMENT 009113.02 – ADDENDUM 02

1.1 PROJECT INFORMATION

B. Project Name: Soda Springs Park Playground Improvements

1. Owner: City of Manitou Springs

2. Owner Project Number 2024-014

3. Landscape Architect: Hord Coplan Macht (HCM).

4. Landscape Architect Project Number: 223108

1.2 NOTICE TO BIDDERS

A. This Addendum is issued to all registered plan holders pursuant to the Instructions to Bidders and Conditions of the Contract.

B. Incorporate the following modifications, corrections, additions and /or deletions into the Drawings, Specifications, and Construction Documents issued for this project.

C. This Addendum is dated August 28, 2024, and will be attached to and become part of the Contract Documents dated March 22, 2024, and submitted with the Contract.

D. There have been occasions when the failure of a Contractor to acknowledge receipt of Addenda has cost him/her the award of a Contract. Please acknowledge receipt of this Addendum on the Bid Form.

1.3 ATTACHMENTS

A. This Addendum includes the following attached Documents and Specification Sections:

1. Response to Bidder Questions, dated 08.28.2024.

2. Irrigation As-builts from phase 1.

1.4 REVISIONS TO DRAWING SHEETS

A. N/A

END OF DOCUMENT 009113.02

8/28/2024

Contractor: # Reference: Question: Response:

These questions were received prior to the deadline for questions but were missed. Responses to outstanding questions are below.

1 Are any stormwater permits needed? Any other permits?

We have a Flood Plain Development Permit. The contractor will need to get

Grading/Erosion Control Permit through the City. The contract documents include erosion control drawings. Erosion control will be monitored by the City during construction.

2 Are utilities located along Park Avenue (in between sidewalk and park)? All known utilities are shown on the existing conditions.

3 Who is responsible for street closures/ traffic control? The contractor is responsible for this.

4 Are playground equipment use zones already calculated and accounted for? Yes, all use zones are accounted for on the drawings.

5 When does the warranty period begin for the project? The warranty period begins when Substantial Completion is approved.

6 Will there be testing for the concrete? Yes. The city will contract with a 3rd party for testing.

Will there be form inspections? Yes. The city will contract with a 3rd party for testing. The design team will also perform inspections

8 Will there be form Compaction testing?

Yes. The city will contract with a 3rd party for testing. The design team will also perform inspections

9 Can you confirm the existing Mosaic Wall attachment. Concrete footer or dirt base? The wall attachment is a concrete footer.

10 Can you confirm the footing size for the existing playground equipment to be removed? The foundation sizes of existing playground equipment are unknown.

For “Fix existing irrigation,” (on I-100) Is there known issues, and if so, can you describe them? Is there a SF area where there are issues with existing irrigation?

No known issues. Repair any damage to existing irrigation that may occur during construction.

12 Do you have as-builts of the existing irrigation? As-built drawings for irrigation for phase 1 are attached.

The spec calls out a years’ worth of mowing and other maintenance items. Can you confirm what the maintenance will cover and add a line item for this or direct us where to include the cost?

Please disregard the 1 year of mowing. There is only a 12 month warranty from date of planting completion for plants and sod.

Soda Springs Park Playground

Improvements

Contractor Bidding Questions

GS

GS

GS

GS

GS

GS

GS

GS

GS

GS

GS

GS

GS

GS

GS

GS

GS

GS

GS

GS

GS

GS

GS

GS

GS

GS

TS

TS

TS

TS

TS

TS

TS

TS

TS

TS

IR

IR

W

MH

GS

GS

GS

GS

GS

GS

GS

GS

GS

GS

CO

CO

M

ANITOU AVE

FOUNTAIN CREEK

PARK AVE

M

F

R

11/2" 11/2"

11/2"

11/2"

A2

11 1"

A1

6 1"

A4

11 1"

A3

7 1"

A5

14 1"

A6

14 1"

CONSULTANT:

ISSUE:

OWNER:

PROJECT:

DRAWING INFORMATION:

DRAWN BY:

PROJECT NO:

SHEET TITLE:

APPROVED BY:

CHECKED BY:

SHEET OF

1 2 3 4 5 6

A

B

C

D

E

1 2 3 4 5 6

P 303.607.0977 www.hcm2.com

1800 Wazee Street

Suite 450

Denver, CO 80202 hord|coplan|macht

DATE: 10/23/2020

SEAL:

J O

B S

S

O D

A

S

P R

I N

G S

P

A R

K

D

R A

W I N

G S

L

C

D

B

I M

X

R E

F X

T

I T

L E

B L O

C K

D

W G

CITY OF MANITOU

SPRINGS

SODA SPRINGS PARK

DZ

DZ

220109.00

DZ

35 PARK AVENUE

MANITOU SPRINGS, COLORADO 80829

606 MANITOU AVENUE

MANITOU SPRINGS, COLORADO 80829

CIVIL ENGINEER:

COLLINS ENGINEERS, INC.

455 SHERMAN STREET

DENVER, COLORADO 80203

LIGHTING / ELECTRICAL ENGINEER:

AE DESIGN

1900 WAZEE STREET, SUITE 205

DENVER, COLORADO 80202

IRRIGATION DESIGN:

AVOCET IRRIGATION DESIGN

7114 WEST JEFFERSON AVENUE

LAKEWOOD, COLORADO 80235

No. Date Revision

I-101

IRRIGATION PLAN -

PHASE 1

1" = 10'-0"

A1

IRRIGATION PLAN - PHASE 1

0' 5' 10' 20' 30'

SCALE: 1" = 10'-0"

REMOVE EXISTING METER AT INDICATED LOCATION. INSTALL NEW 3/4" METER

ASSEMBLY WITHIN NEW PIT PER DETAIL. EXTEND 3/4" K COPPER AT 54" DEPTH TO

BACKFLOW PREVENTER LOCATION. INSTALL 3/4" STOP AND WASTE VALVE AT 54"

DEPTH IN PLAY PIT ADJACENT TO RETAINING WALL. WITHIN ELEVATED PLANTER

AREA INSTALL ONE 3/4" REDUCED PRESSURE BACKFLOW PREVENTER AND

ENCLOSURE, ONE 3/4" MANUAL DRAIN VALVE, ONE 1" FLOW SENSOR, ONE QUICK

COUPLING VALVE, ONE 1" MASTER VALVE AND EXTEND SCHEDULE 40 PVC MAINLINE

AS SHOWN. WORK SHALL CONFORM TO LOCAL CODE. FEES AND PERMITS

ASSOCIATED WITH WORK ARE TO BE OBTAINED AND PAID BY CONTRACTOR. FINAL

LOCATION OF BACKFLOW PREVENTER AND OTHER IRRIGATION EQUIPMENT SHALL

BE REVIEWED AND APPROVED BY OWNER'S REPRESENTATIVE PRIOR TO START OF

WORK.

REMOVE EXISTING CONTROLLER AND POST. RETURN CONTROLLER TO OWNER.

DISPOSE OF POST.

INSTALL RAIN BIRD ESP-LXMEF SERIES 12 STATION CONTROLLER WITHIN

ENCLOSURE AT SAME LOCATION. RECONNECT 120 VOLT ELECTRICAL POWER TO

CONTROLLER. ELECTRICAL POWER AND CONNECTION TO CONTROLLER IS BY

CONTRACTOR WITH WORK CONFORMING TO LOCAL CODE. FEES AND PERMITS

ASSOCIATED WITH WORK ARE TO BE OBTAINED AND PAID BY CONTRACTOR. FINAL

LOCATION OF CONTROLLER SHALL BE REVIEWED AND APPROVED BY OWNER'S

REPRESENTATIVE PRIOR TO INSTALLATION.

EXTEND EIGHT SPARE BLACK CONTROL WIRES WITH COMMON FROM CON-

TROLLER "A" TO INDICATED LOCATION. STUB WIRES IN VALVE BOX CON-

TAINING GATE VALVE.

CONNECT NEW MAINLINE TO EXISTING MAINLINE AT APPROX. LOCATION

SHOWN. EXTEND THREE RED CONTROL AND ONE WHITE COMMON WIRES

TO SAME LOCATION AND CONNECT TO EXISTING WIRING FOR THREE

EXISTING ELECTRIC VALVES.

CONNECT NEW MAINLINE TO EXISTING MAINLINE AT APPROX. LOCATION

SHOWN. EXTEND ONE RED CONTROL AND ONE WHITE COMMON WIRES

TO SAME LOCATION AND CONNECT TO EXISTING WIRING FOR ONE EXIST-

ING ELECTRIC VALVES.

CORE DRILL (4" DIA.) EXISTING CONCRETE WALL AT 24" DEPTH OF COVER

(MEASURED FROM TOP OF SOIL WITHIN PLAY PIT AREA) TO ACCEPT INSTAL-

LATION OF NEW MAINLINE AND IRRIGATION WIRES.

RESTORE EXISTING LANDSCAPE AND IRRIGATION SYSTEM DAMAGED BY NEW

CONSTRUCTION TO ORIGINAL CONDITION AND TO THE SATISFACTION OF THE

OWNER.

UNLESS NOTED OTHERWISE

RD-12-S-P30-F W/ HE-VAN NOZZ.

NIBCO

SCHEDULE 40 SOLVENT WELD

100 PSI NSF - 1" DIA.

PEB SERIES

ESP-LXMEF SERIES W/

SCHEDULE 40 SOLVENT WELD

GPM

RAIN BIRD

FEBCO

RAIN BIRD

RAIN BIRD

RAIN BIRD

CONTROL VALVE SIZE

CONTROLLER & STATION NO.

ELECTRIC CONTROL VALVE

ELECTRIC CONTROLLER

QUICK COUPLING VALVE

BACKFLOW PREVENTER

PVC MAINLINE

825YA - 3/4"

3/4"

44 NP

WATER METER

POLYETHYLENE LATERAL

PVC SLEEVING

GATE VALVE

12 & 13

MODEL NO.SYMBOL MANUFACTURER DESCRIPTION DETAIL NO. COMMENTS

WR2-RFCRAIN BIRD WIRELESS RAIN/FREEZE SENSOR 11R

EFB-CP SERIES - 1" DIA.RAIN BIRD MASTER VALVE 3 & 12

3/4" DIA. MANUAL DRAIN VALVE 6

T113K - LINE SIZE

W/ CELLULAR IQ

COMMUNICATION

CARTRIDGE

F

M

FS-100B - 1" DIA.RAIN BIRD FLOW SENSOR 4 & 12

H10284N SERIES - 3/4" DIA.MUELLER CORP. STOP & WASTE VALVE 12

IQ4G-USA COMM. CARTRIDGE

RD-06-S-P45-F W/ R-VAN24 NOZZ.RAIN BIRD 1

RD-06-S-P45-F W/ R-VAN24-360 NOZZ.RAIN BIRD 1

HI-POP HEAD HEAD W/ SPEC'D NOZZ.

POP-UP HEAD W/ ROTARY NOZZ.

POP-UP HEAD W/ ROTARY NOZZ.

RAIN/FREEZE SENSOR - MOUNT ON LIGHT

POLE AT 10-12 FT. HT.

CONTRACTOR SHALL FIELD VERIFY PRESSURE AT BACKFLOW PREVENTER LOCATION

FOR EACH TAP PRIOR TO ORDERING MATERIALS OR STARTING ANY IRRIGATION

INSTALLATION AND NOTIFY CONSULTANT OF ANY DIFFERENCES FROM STATED

PRESSURE. IF CONTRACTOR FAILS TO NOTIFY CONSULTANT HE ASSUMES FULL

RESPONSIBILITY FOR ANY SYSTEM ALTERATIONS. EACH SYSTEM HAS BEEN

DESIGNED FOR A STATIC PRESSURE OF 180 PSI (PER CITY OF MANITOU SPRINGS).

LATERAL PIPING DIAMETERS SHALL INCLUDE 1". 3/4" AND 1 1/4" DIAMETER LATERAL

PIPE IS NOT ACCEPTABLE.

REFER TO IRRIGATION TECHNICAL SPECIFICATIONS FOR PLANTING AND IRRIGATION

LAY-OUT REQUIREMENTS, COORDINATION AND PRIORITIES.

VALVE BOXES SHALL BE LOCATED 36" MINIMUM FROM CENTERLINE OF ALL SWALES,

24" MINIMUM FROM EDGES OF ALL WALKS, CURBS, DRIVES AND OTHER HARD

SURFACE AREAS.

SEPARATE SLEEVE. IRRIGATION WIRE BUNDLE SHALL BE ROUTED IN SEPARATE

CONTRACTOR SHALL REPAIR OF REPLACE ANY EXISTING IRRIGATION EQUIPMENT,

TURF, PLANT MATERIAL OR SITE FEATURES DAMAGED DURING NEW INSTALLATION.

REPLACEMENT OR REPAIR OF DAMAGED EQUIPMENT OR MATERIAL SHALL BE

DETERMINED BY THE OWNER AND THE CONSULTANT.

REFER TO PLANTING PLAN FOR EXACT TREE LOCATIONS AND QUANTITIES, TREES

SHOWN ON IRRIGATION PLANS ARE APPROXIMATE.

CONTRACTOR SHALL COORDINATE INSTALLATION OF SLEEVING WITH INSTALLATION OF

CONCRETE FLATWORK AND PAVING. ALL SLEEVING IS BY CONTRACTOR UNLESS OTHERWISE

NOTED. UNLESS NOTED OTHERWISE ON IRRIGATION PLANS INSTALL SLEEVING BASED ON

SLEEVE SIZING GUIDE BELOW:

NOTE: EACH LENGTH OF SLEEVED PIPE SHOWN SHALL BE ROUTED THROUGH

SLEEVE/CONDUIT WITHOUT IRRIGATION PIPING

PIPE SIZE OR WIRE QUANTITY

TAP LOCATION/NUMBER

8.

9.

7.

5.

6.

4.

1-1/2" - 2" PIPING

1-25 CONTROL WIRES

3/4" - 1" PIPING

1-4" PVC SLEEVE

1-2" PVC SLEEVE

80 PSI

PRV SETTING AT METER

REQUIRED SLEEVE

1-2" PVC SLEEVE

REFER TO TECHNICAL SPECIFICATIONS AND CONSTRUCTION DETAILS FOR

INSTALLATION PROCEDURES.

ALL BASE INFORMATION HAS BEEN TAKEN FROM DRAWINGS PREPARED BY HORD

COPLAN MACHT.

1.

3.

2.

Know what's below before you dig.

Call

R

EXIST. MAINLINE

EXIST. MAINLINE

HAND-DIG IRRIGATION TRENCHES WITHIN DRIP LINES OF

EXISTING TREES (TYP.) - RE: TREE PROTECTION SPECS.

EXTEND THREE SPARE GREEN CONTROL WIRES WITH COMMON FROM CON-

TROLLER "A" TO INDICATED LOCATION. STUB WIRES IN VALVE BOX CON-

TAINING GATE VALVE.

SEE NOTE #10, THIS SHT.

SEE NOTE #10, THIS SHT.

SEE NOTE #10, THIS SHT.

BASE BID

BASE BID

BASE BID FOR DESIGNATED VALVES SHALL CONSIST OF SERVICE TEE, CAPPED 1"x12"

SCH. 80 PVC RISER NIPPLE, CONTROL WIRE EXTENDED FROM CONTROLLER AND

WHITE COMMON WIRES STUBBED IN 10" RD. VALVE BOX. REFER TO DETAIL #14.

ALTERNATE BID FOR DESIGNATED VALVE SHALL INCLUDE FULL INSTALLATION OF

ZONE PER DETAILS INCLUDING HEADS, LATERAL PIPING AND ELECTRIC VALVE.

10.

ALL IRRIGATION HEADS AND LATERAL PIPING WITHIN INDICATED TURF AREA ARE

A PART OF ALTERNATE NO. 1. REFER TO NOTE #10, THIS SHEET, FOR INFORMATION

PERTAINING TO TURF IRRIGATION VALVES.

BRASS BODY

BASE BID

W/ FLOW SENSING CAPABILITY

CONSULTANT:

ISSUE:

OWNER:

PROJECT:

DRAWING INFORMATION:

DRAWN BY:

PROJECT NO:

SHEET TITLE:

APPROVED BY:

CHECKED BY:

SHEET OF

1 2 3 4 5 6

A

B

C

D

E

1 2 3 4 5 6

P 303.607.0977 www.hcm2.com

1800 Wazee Street

Suite 450

Denver, CO 80202 hord|coplan|macht

DATE: 10/23/2020

SEAL:

J O

B S

S

O D

A

S

P R

I N

R

K

D

R A

W I N

G S

L

A

C

A D

B

I M

X

R E

F

X T

I T

L E

B L

O C

K D

W G

CITY OF MANITOU

SPRINGS

SODA SPRINGS PARK

DZ

DZ

220109.00

DZ

35 PARK AVENUE

MANITOU SPRINGS, COLORADO 80829

606 MANITOU AVENUE

MANITOU SPRINGS, COLORADO 80829

CIVIL ENGINEER:

COLLINS ENGINEERS, INC.

455 SHERMAN STREET

DENVER, COLORADO 80203

LIGHTING / ELECTRICAL ENGINEER:

AE DESIGN

1900 WAZEE STREET, SUITE 205

DENVER, COLORADO 80202

IRRIGATION DESIGN:

AVOCET IRRIGATION DESIGN

7114 WEST JEFFERSON AVENUE

LAKEWOOD, COLORADO 80235

No. Date Revision

I-102

IRRIGATION DETAILS

TO FINISH GRADE

NOTE: SET HEAD PERPENDICULAR

1/2" MIPxFIP SCH. 40 PVC ELL

APPLICABLE

CURB & GUTTER, SIDEWALK

OR HARD SURFACE WHERE

POP-UP SPRAY HEAD

POLYETHYLENE LATERAL PIPING W/ INSERTx1/2"

SET BOTTOM OF CAP AT GRADE

FIPT FITTING AND STAINLESS STEEL CLAMPS

3"

DOUBLE CLAMP 1 1/2" & 2" DIAMETER FITTINGS

30-60

DEGREES

(SPEARS BLUE 75 OR EQUAL)

PETROLEUM DISTILLATES TO ALL MALE-THREADED FITTINGS

APPLY NON-HARDENING THREAD SEALANT CONTAINING NO

1/2" PVC MIPTxBARB SWING PIPE FITTING

1/2" DIA. POLYETHYLENE SWING/FLEX PIPE - 8"-12"

1/2" PVC MIPTxBARB SWING PIPE FITTING

VALVE BOXES SHALL BE INSTALLED PARALLEL OR PERPENDICULAR

TO ADJACENT SIDEWALKS AND HARD SURFACES WHERE APPLICABLE

NOTE: DIAMETERS OF BALL VALVES, PVC FITTINGS AND NIPPLES

DUCTILE, GASKETED FITTING - REFER

SERVICE TEE - SOLVENT WELD PVC OR

SCH. 80 PVC NIPPLE - LENGTH AS

3/4" WASHED RIVER ROCK SUMP - FILL BOX TO

SHALL EQUAL ELECTRIC CONTROL VALVE DIAMETER

BOTTOM OF VALVE BODY

CONTROL WIRE BUNDLE

REQUIRED

TO SPECIFICATIONS

CENTER BOX OVER ASSEMBLY

PVC MIPTxINSERT ADAPTER

CONTROL/COMMON WIRING WITHIN VALVE

PROVIDE 12" CONTINUOUS COILS OF ALL SPARE

POLY LATERAL PIPING - SWEEP TO SPECIFIED DEPTH

REFER TO TECHNICAL SPECIFICATIONS.

LID WITH CONTROLLER & STATION #.

RECTANGULAR VALVE BOX. BRAND

PVC BALL VALVE - FIPTxFIPT

4"-5"

ELECTRIC CONTROL VALVE

BOX

FINISH GRADE

STAINLESS STEEL CLAMP - INSTALL TWO CLAMPS ON

1 1/2" & 2" DIA. FITTINGS

(SPEARS BLUE 75 OR EQUAL)

PETROLEUM DISTILLATES TO ALL MALE-THREADED FITTINGS

APPLY NON-HARDENING THREAD SEALANT CONTAINING NO

WATERPROOF WIRE SPLICE KIT - RE: SPECS.

ASSEMBLY.

NOTE: CENTER BOX OVER VALVE

BOTTOM OF VALVE AND PIPING

3/4" WASHED RIVER ROCK SUMP - ADD TO

RECTANGULAR VALVE BOX WITH

EXTENSION - BRAND "MV" INTO

VALVE BOX LID. REFER TO

TECHNICAL SPECIFICATIONS.

DIAMETER

FOR MANUFACTURER, MODEL # AND

REFER TO EQUIPMENT SCHEDULE

ELECTRIC MASTER CONTROL VALVE

FINISH GRADE

PRESSURE MAINLINE

SLIPxMIPT SCH. 40 PVC ADAPTER (2)

#14 AWG UFUL WIRES (MASTER VALVE

SOLENOID) - ONE BLUE, ONE GREEN -

EXTEND TO CONTROLLER - (RE: IRRIG.

36" COIL #14 AWG UFUL WIRING (SPARE

MASTER VALVE WIRE) - BROWN.

(SPEARS BLUE 75 OR EQUAL)

PETROLEUM DISTILLATES TO ALL MALE-THREADED FITTINGS

APPLY NON-HARDENING THREAD SEALANT CONTAINING NO

WATERPROOF WIRE SPLICE KIT - RE: SPECS

1" BRASS NIPPLE

LENGTH AS REQUIRED

3" OF BOTTOM OF QCV LID

SPECIFICATIONS.

LID. REFER TO TECHNICAL

BRAND "QC" INTO VALVE BOX

10" ROUND VALVE BOX

QUICK COUPLING VALVE

SUMP - FILL BOX TO WITHIN

3/4" WASHED RIVER ROCK

FINISH GRADE

3"

SOLVENT WELD OR GASKETED FITTING

REFER TO SPECIFICATIONS

PRESSURE MAINLINE SERVICE TEE -

1-1"x3" SCH.80 PVC NIPPLE

1" SCH.80 PVC FIPxFIP 90 ELL

1"x12" SCH.80 PVC NIPPLE

1" BRASS FIPxFIP 90 ELL

1" SCH.80 PVC FIPxFIP

1-1x3" SCH.80 PVC NIPPLE

90 ELL

(SPEARS BLUE 75 OR EQUAL)

PETROLEUM DISTILLATES TO ALL MALE-THREADED FITTINGS

APPLY NON-HARDENING THREAD SEALANT CONTAINING NO

APPLY NON-HARDENING THREAD SEALANT CONTAINING NO

PETROLEUM DISTILLATES TO ALL MALE-THREADED FITTINGS

(SPEARS BLUE 75 OR EQUAL)

SCH. 40 PVC MALE ADAPTER (TWO REQ'D.)

SHALL BE INSTALLED WITHIN FLOW SENSOR TEE.

SHALL BE EQUAL. NO REDUCER BUSHINGS, ADAPTERS, ETC.

DIAMETER OF FLOW SENSOR TEE AND "METER RUN" PIPING

MIN. UPSTREAM

10x PIPE DIA.

SHALL BE INSTALLED WITHIN "METER RUN" SEGMENT OF PIPING

NO FITTINGS INCLUDING REDUCER BUSHINGS, TEES, ELLS, ETC,

REFER TO PLANS FOR PIPE DIAMETER

METER RUN

DOWNSTREAM

5x PIPE DIA. MIN.

FINISH GRADE

PVC PRESSURE MAINLINE - REFER TO PLAN FOR

PE-89 CABLE

ALLOW REMOVAL OF SENSING UNIT FROM BOX

PROVIDE ADDITIONAL CABLE WITHIN BOX TO

FOR SIZE.

3/4" GRAVEL SUMP - 2 CU. FT.

FOR MAINTENANCE PURPOSES.

(SPEARS BLUE 75 OR EQUAL)

PETROLEUM DISTILLATES TO ALL MALE-THREADED FITTINGS

APPLY NON-HARDENING THREAD SEALANT CONTAINING NO

FLOW

AS REQUIRED. BRAND "FS" INTO VALVE BOX LID.

REFER TO TECHNICAL TO TECHNICAL SPECIFICATIONS

AND PREFORMED SUPER SERVISEAL SPLICE

DATA CABLE SPLICE CONSISTING OF WIRE NUTS

VALVE BOX SHALL NOT REST DIRECTLY ON FLOW

RECTANGULAR VALVE BOX WITH EXTENSIONS

KIT

FOR MANUFACTURER, MODEL & DIAMETER

SENSOR CABLE

FLOW SENSOR - REFER TO EQUIPMENT SCHEDULE

VALVE BOX SHALL NOT REST OF TOP OF FLOW SENSOR CABLE

EXTEND TO CONTROLLER PER PLAN NOTES

PVC PRESSURE MAINLINE

SEE TECHNICAL SPECIFICATIONS

3/4" WASHED RIVER ROCK SUMP

3/4"x4" PVC NIPPLE SCH. 80

3/4" MxF SCH.40 PVC 90 ELL

SOIL BLANKET COVERING SUMP

3/4" BRASS BALL CURB VALVE W/ SLOT-TYPE OPERATOR

FOR SUMP SIZE

4"

FINISH GRADE

3/4"x6" BRASS NIPPLE - LENGTH AS REQUIRED

3/4"xCL PVC NIPPLE SCH. 80 (2) 3/4" FxF SCH.80 PVC 90 ELL (2)

2" CL200 PVC ACCESS SLEEVE -

3/4" WASHED RIVER ROCK SUMP

TECHNICAL SPECIFICATIONS

THE LETTER "D" IN LID- REFER TO

10" ROUND VALVE BOX - BRAND

LENGTH AS REQUIRED

1 CU. FT.

2" VALVE MARKER

TO PROVIDE ADEQUATE CLEARANCE OF MAIN PIPING

(SPEARS BLUE 75 OR EQUAL)

PETROLEUM DISTILLATES TO ALL MALE-THREADED FITTINGS

APPLY NON-HARDENING THREAD SEALANT CONTAINING NO

MUELLER CO. #B-20287N SERIES

18"

BACKFILL MATERIAL (TYPICAL)

CONTROL WIRES

PVC MAINLINE

FINISH GRADE

18"

12"

HI-POP SPRAY HEAD LATERAL

6" SPRAY HEAD AND BUBBLER

LATERAL PIPING, DRIP

NOTE: REFER TO TECHNICAL SPECIFICATIONS

FOR MINIMUM TRENCH WIDTHS.

TUBING IN TURF OR SEED

REFER TO TECHNICAL SPECIFICATIONS

AREAS.

VALVE BOX. REFER TO

BRAND "GV" ON LID OF

3"

GATE VALVE W/ CROSS HANDLE

PVC PRESSURE MAINLINE

PRESSURE MAINLINE

AND CONTACT TOP OF

BOTTOM TO BE NOTCHED

6" CLASS 160 PVC SLEEVE

10" ROUND VALVE BOX

SCH. 40 PVC MALE ADAPTER (2) - SIZE

TECHNICAL SPECIFICATIONS.

FINISH GRADE

TO EQUAL GATE VALVE DIAMETER

2"

OF 6" PVC ACCESS SLEEVE

FILL BOX TO WITHIN 2" OF TOP

3/4" WASHED RIVER ROCK SUMP -

UNDISTURBED SOIL

AND SOLID WEDGE DISC

(SPEARS BLUE 75 OR EQUAL)

PETROLEUM DISTILLATES TO ALL MALE-THREADED FITTINGS

APPLY NON-HARDENING THREAD SEALANT CONTAINING NO

8 FT.

CONTINUOUS #6 BARE COPPER GROUNDING WIRE

ROD & 10" ROUND VALVE BOX

5/8"x8 FT. COPPER-CLAD GROUNDING

MANUFACTURER"S RECOMMENDATIONS AND GROUND

PROTECTION FOR CONTROLLER IN ACCORDANCE WITH

CONTRACTOR TO GROUND AND PROVIDE SURGE

6"

1" PVC CONDUIT W/ SWEEP ELL - GROUND WIRE

3/4" PVC CONDUIT W/ SWEEP ELL - 120v SERVICE

3" PVC CONDUIT W/ SWEEP ELL - CONTROL WIRES

CONCRETE PAD

5"

1"

CONTROLLER ENCLOSURE - STRONG BOX

FINISH GRADE

SLOPE

0.5%

6"

18"

6"

ALL ELECTRICAL WORK TO CONFORM TO LOCAL CODE.

NOTES:

ROD(S) SHOWN. CONTROLLER GROUNDING SHALL

COMPLY W/ MANUFACTURER'S SPECIFICATIONS.

PLAN VIEW

PROVIDE 48" LENGTH OF ALL SPARE WIRES WITHIN

PEDESTAL, NEATLY COILED.

CADWELD GT1161G "ONE SHOT" WELD (GROUND ROD

CLAMP IS NOT ACCEPTABLE)

SB-18SS

CONTROLLER - REFER TO IRRIGATION EQPT. SCHEDULE

GFI RECEPTACLE WITHIN PEDESTAL

INSTALL A DISCONNECT SWITCH AND 120 VOLT

DISCONNECT SWITCH & RECEPTACLE

3/4" NON-METALLIC LIQUIDTITE CONDUIT W/ MALE

ADAPTERS (2) AND LOCK RINGS, WASHERS

CONTROL WIRES - NEATLY BUNDLE WIRING & SECURE

W/ LOCKING WIRE TIES

SENSOR TO BE ABOVE GUTTER AND/

WITHIN CONTROLLER PEDESTAL

NOTE: MOUNT RAIN SENSOR RECEIVER

SECURE BRACKET VIA WOOD SCREWS OR SIMILAR

RAIN BIRD WR2-RFC RAIN/FREEZE

BUILDING EAVE, FENCE POST, ETC.

OR ANY OBSTRUCTIONS

FINAL LOCATION OF SENSOR SHALL BE

APPROVED BY OWNER PRIOR TO

INSTALLATION.

PVC MAIN - TO IRRIG. SYSTEM (RE: PLAN)

(BACKFLOW DIA.xMAIN DIA.) - RE: PLAN

PROTECTIVE ENCLOSURE- REFER

TO DETAIL

CxM ADAPTER (TWO REQUIRED)

PREVENTER

REDUCED PRESSURE BACKFLOW

SCH. 40 PVC SxS REDUCER BUSHING

QUICK COUPLING VALVE - INSTALL

PER Q.C.V. DETAIL

MASTER VALVE (REFER TO DETAIL)

FLOW SENSOR (REFER TO DETAIL)

INSTALL PER DETAIL

3/4" MANUAL DRAIN VALVE -

BRONZE UNION - SWxSW

ADJUSTABLE CAST IRON STOP

GRAVEL SUMP

SOIL FILTER FABRIC COVERING

COPPER

RIGID

TYPE "K"

SCHEDULE

REFER TO IRRIGATION

PVC PRESSURE MAINLINE

12"

NOTE:

CONCRETE PAD PENETRATIONS TO BE 1"

LARGER THAN TUBING DIAMETER

6" THICK CONCRETE PAD LENGTH

AS REQUIRED 30" MIN. WIDTH

STOP AND DRAIN VALVE - LINE SIZE

3/4" WASHED RIVER ROCK SUMP - 2 CU. FT.

COPPER SERVICE LINE FROM WATER METER

EQEQ 12"BOX - TYLER OR EQUAL

UNLESS NOTED OTHERWISE.

EQUAL DIAMETER OF BACKFLOW PREVENTER

DIAMETER OF FITTINGS, NIPPLE AND TUBING SHALL

PAD DIMENSIONS

REFER TO ENCLOSURE DETAIL FOR CONCRETE

FINISH GRADE

TOP OF SLAB TO BE 1" ABOVE

DIA.

10x PIPE

DIA.

5x PIPE

X

STRONGBOX ENCLOSURE W/ POLAR BARRIER

EQ EQ

Y

CL

6" 6" 16"Y

EQ

1" 5"

CONCRETE PAD

PLAN

TOP SURFACE OF CONCRETE PAD SHALL

BE 1" ABOVE FINISH GRADE.

EQ

CL LC

PAD PENETRATIONS FOR BACKFLOW

PREVENTER RISERS TO BE 1" LARGER

THAN RISER DIAMETER

INSTALL ENCLOSURE ANCHORS AS PER MANUFACTURER'S

RECOMMENDATIONS.

PROVIDE OWNER WITH KEYED PADLOCK FOR ENCLOSURE

6" 6"

BFP MODEL/SIZE

FEBCO 825YA 3/4" & 1"

ENCLOSURE MODEL

SBBC-22ALI

X Y

22" 34"

NOTES

30"

BLANKET

NOTE: SET HEAD PERPENDICULAR TO

1/2" MALExBARB 90 ELBOW

1/2" MALExBARB ADAPTER

FIPT FITTING

POLY LATERAL PIPING W/ INSERTx1/2"

1/2" FLEX PIPE (24" MAX. LENGTH)

FINISH GRADE

12" HI-POP SPRAY HEAD

CURB AND GUTTER, SIDEWALK OR

HARD SURFACE WHERE APPLICABLE

SET BOTTOM OF CAP AT GRADE

6"

DOUBLE CLAMP 1 1/2" & 2" DIAMETER FITTINGS

SWING JOINT CONNECTION

SIDE INLET IS NOT TO BE UTILIZED FOR

(SPEARS BLUE 75 OR EQUAL)

PETROLEUM DISTILLATES TO ALL MALE-THREADED FITTINGS

APPLY NON-HARDENING THREAD SEALANT CONTAINING NO

10" ROUND VALVE BOX

FINISH GRADE

IRRIGATION WIRING (14 GA.)

1"x12" SCH. 80 PVC NIPPLE

1" SCH. 80 PVC CAP

PVC MAINLINE

SCH. 40 PVC SERVICE TEE (MAINLINE DIA.

x 1")

BASE BID CONFIGURATION AT DESIGNATED VALVE LOCATIONS SHOWN ON PLANS

EXISTING CONCRETE WALL - DEPTH

OF WALL IS NOT KNOWN

54" MIN.

PLAY PIT AREA

ENG. WOOD FIBER

TOP OF SOIL IN PIT

PIPING

LOOPED WHITE COMMON WIRE

STUBBED RED CONTROL WIRE (36" LENGTH)

CONSULTANT:

ISSUE:

OWNER:

PROJECT:

DRAWING INFORMATION:

DRAWN BY:

PROJECT NO:

SHEET TITLE:

APPROVED BY:

CHECKED BY:

SHEET OF

1 2 3 4 5 6

A

B

C

D

E

1 2 3 4 5 6

P 303.607.0977 www.hcm2.com

1800 Wazee Street

Suite 450

Denver, CO 80202 hord|coplan|macht

DATE: 10/23/2020

SEAL:

J O

B S

S

O D

A

S

P R

I N

R

K

D

R A

W I N

G S

L

A

C

A D

B

I M

X

R E

F

X T

I T

L E

B L

O C

K D

W G

CITY OF MANITOU

SPRINGS

SODA SPRINGS PARK

DZ

DZ

220109.00

DZ

35 PARK AVENUE

MANITOU SPRINGS, COLORADO 80829

606 MANITOU AVENUE

MANITOU SPRINGS, COLORADO 80829

CIVIL ENGINEER:

COLLINS ENGINEERS, INC.

455 SHERMAN STREET

DENVER, COLORADO 80203

LIGHTING / ELECTRICAL ENGINEER:

AE DESIGN

1900 WAZEE STREET, SUITE 205

DENVER, COLORADO 80202

IRRIGATION DESIGN:

AVOCET IRRIGATION DESIGN

7114 WEST JEFFERSON AVENUE

LAKEWOOD, COLORADO 80235

No. Date Revision

I-103

IRRIGATION DETAILS

MODEL #223-HP (SIZE TO MATCH METER) -

PRESSURE REDUCING VALVE TO BE WATTS

NO EQUALS.

GRADE WITHIN PLAY PIT AREA. ENG. WOOD

LID OF METER PIT TO BE 1/2" ABOVE FIN.

FIBER TO COVER LID.

Soda Springs Park Playground_Addendum 02
1. DOCUMENT 009113.02 – ADDENDUM 02
1.1 PROJECT INFORMATION
B. Project Name: Soda Springs Park Playground Improvements
1. Owner: City of Manitou Springs
2. Owner Project Number 2024-014
3. Landscape Architect: Hord Coplan Macht (HCM).
4. Landscape Architect Project Number: 223108
1.2 NOTICE TO BIDDERS
A. This Addendum is issued to all registered plan holders pursuant to the Instructions to Bidders and Conditions of the Contract.
B. Incorporate the following modifications, corrections, additions and /or deletions into the Drawings, Specifications, and Construction Documents issued for this project.
C. This Addendum is dated August 28, 2024, and will be attached to and become part of the Contract Documents dated March 22, 2024, and submitted with the Contract.
D. There have been occasions when the failure of a Contractor to acknowledge receipt of Addenda has cost him/her the award of a Contract. Please acknowledge receipt of this Addendum on the Bid Form.
1.3 ATTACHMENTS
A. This Addendum includes the following attached Documents and Specification Sections:
1. Response to Bidder Questions, dated 08.28.2024.
2. Irrigation As-builts from phase 1.
1.4 REVISIONS TO DRAWING SHEETS
A. N/A
Soda Springs Park Playground_Questions from Contractors ADD 2
Phase 1 IRRIGATION

File details come from the government source that posted it. Updated .