This is a Statement of Work for comprehensive maintenance and support of a Video Teleconferencing (VTC) and Audio/Visual (A/V) system located in building 1624, conference room 203, at Hanscom Air Force Base, MA. The system must support both classified and unclassified video teleconferencing with NIPR/SIPR Teams capabilities through a single CODEC with automated periods processing hardware. The contractor must evaluate existing equipment against current security and compliance standards governed by DISA Risk Management Executive (RME) Vendor Security Technical Implementation Guides (STIG) program and Unified Capabilities Requirements (UCR)-CORE document. All replacement parts must comply with DISA policy, and the system must maintain GVS comparability. The system is non-radio with no Wi-Fi, Bluetooth, or wireless communication methods enabled.

Key hardware upgrades include replacing the CISCO Precision 60 PTZ camera with a high-definition PTZ camera (QSC NC-20-60 recommended) that has two ports for SIPR GVS and SIPR TEAMS laptop app; replacing the VTC CODEC with a modern IP-based equivalent supporting Voice over IP audioconferencing; replacing the rack UPS with a Smart Online UPS featuring Double Conversion; replacing the single 32-inch operator display with two desktop-standard monitors; upgrading the control system to allow independent simultaneous display output on any room display; adding a white noise system with minimum two speakers at each door; and integrating SIPR Teams audio/video signal from a DoD SIPR laptop into the AV system, potentially requiring a third Freeport SCC unit. The contractor must provide comprehensive documentation including uncompiled CRESTRON source code on disc, signal flow diagrams for audio/video/control in PDF and large-format prints, and wiring schematics with clear labeling. The contract period of performance is 180 days from award, and the contractor must provide one-year warranty on all installed equipment and systems. Training must be provided to at least two Government individuals on system operation and new equipment functionality.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Work (Revised)

AFLCMC/ES VTC and A/V System Maintenance

1.0 Purpose

The purpose of this Statement of Work (SOW) is to secure a contractor to perform comprehensive maintenance and support for the Video Teleconferencing (VTC) and Audio/Visual (A/V) system located in building 1624, conference room 203, at 5 Eglin Street, Hanscom AFB, MA 01731. The contractor shall ensure the system remains fully functional through proactive maintenance, timely hardware replacement, on-call support, and user training.

2.0 Scope of Work

• Provide maintenance for a full audio visual and URL solution for one independent conference room that is capable of both classified and unclassified video teleconferencing (VTC) connectivity.

• Classified and unclassified VTC utilizes a single CODEC, automated periods processing hardware, and has NIPR/SIPR Teams capabilities. The purpose of CODEC is to encode and decode digital video and audio data so that it can be transmitted securely.

• Replacement parts to the VTC AV system shall comply with the established Defense Information Systems Agency (DISA) policy, Video Services Policy Security Technical Implementation Guide (STIG).

• The system will maintain GVS comparability and remain on the Defense Information Systems Agency (DISA) Approved Products List (APL) and be Joint Interoperability Test Command (JITC) approved.

• Video Teleconference equipment must be searched as both terms; VTC and Unified Capabilities Conferencing Systems (UCCS) in the following DISA APL:

https://aplits.disa.mil/processAPList.action.

The contractor's responsibilities include:

• Evaluating all existing A/V equipment against current security and compliance standards.

• Replacing or upgrading components as required to meet the specifications outlined in this SOW.

• Installing, integrating, programming, and testing all new equipment.

• Providing comprehensive documentation and user training.

3.0 Technical Requirements

3.1. System Security and Compliance

Governing Standards: Cybersecurity requirements will be governed by the DISA Risk Management Executive (RME) Vendor Security Technical Implementation Guides (STIG) program. Interoperability requirements will be identified by the Unified Capabilities Requirements (UCR)-CORE document.

(Please note: DISA APL has been sunset, so it is no longer the standard. Moving forward, cybersecurity requirements will transition to the DISA RME Vendor Security Technical Implementation Guides (STIG) program, while interoperability requirements will be identified by the Unified Capabilities Requirements (UCR)-CORE document and enforced through contractual provisions.)

• Prohibited Technology: The system is non-radio. No components shall be enabled for Wi-Fi, Bluetooth, or any other wireless communication method.

• Secure/Non-Secure Status: The existing secure/non-secure marquee indicators, both inside and outside the room, shall remain operational.

• UPS Replacement: The rack UPS needs to be replaced to meet AF compliance.

Smart Online UPS required to include Double Conversion feature, Utilizing current wall sockets and voltages in room 203.

3.2. Hardware and Equipment Upgrades

• Cameras: There are currently two cameras. A CISCO Precision 60 PTZ for SIPR & a recent QSC NC-20-60 PTZ for NIPR via Fiber.

• The CISCO camera may need to be replaced with High definition PTZ camera that has two ports. One for SIPR GVS and one for adding SIPR TEAMS laptop app. Recommend QSC NC-20-60 so, matches current NIPR camera in looks, specifications and functionality.

• Will consider alternate compatible business class PTZ camera’s that specifications are equivalent or better.

• CODEC: The VTC CODEC for the classified and unclassified system shall be replaced with a modern, compliant equivalent that supports IP-based connections and unclassified Voice over IP (VoIP) audioconferencing.

• All replacements must be a DISA approved product and compatible with the existing system. VTC unit can connect via Internet Protocol (IP)

• In addition, it has the ability for Voice over Internet Protocol (VoIP) connections for unclassified audioconferencing. The audioconferencing is programmed to be disabled for classified conferences.

• Operator Display Upgrade:

Note: Operator desk currently has one GFE furnished 32in ViewSonic computer display as that is the largest fit for console. It shall be replaced with two monitors of desktop standard viewing size or larger.

• Upgrade operator area display hardware & program configuration so, any display output can be shown on any room display independently and simultaneously.

• Ability to see Main desktop display presentations or communication apps and extended display separately simultaneously on front screens, that will mirror operator desk monitors.

• The ability for operators to work on local desktop displays will not be seen by attendees so the operator can research questions or check emails.

• Credenza: If current AV cabinet cannot properly be reconfigured to house all required equipment and ensure that the temperature does not exceed the device's maximum MFR operating temperature limits then, the contractor’s proposal will provide estimate for a new locking credenza on casters with built in racks. After Award of contract, the credenza design, material and color must be pre-approved by the Government ES POC prior to purchase. Shall have proper AC voltages and surge protection available where UPS is not utilized. Use existing AV racks for audio-visual equipment that can be locked in a rack system.

3.3. Control System and User Interface

• Touch Panels:

• If touch panel replacement is required for compatibility, new screens no smaller than 10 inches shall be installed. The existing design, coloring, and icon style of the touch panel interface shall not be changed without Government consent (21.5 in at Operator desk & 10.1in at conference table.)

• The ES logo on the touch panels must be updated, and the time display must be set to Eastern Standard Time. This feature should be user-friendly for future modifications.

• SIPR Teams Integration: The newly introduced SIPR Teams audio/video signal data will come from DoD SIPR laptop connected at operator console and shall be wired and programmed into AV rack/touch panel system.

• May require adding a (3rd Freeport SCC unit to current periods processing system.)

• Camera Control: The control system must allow the SVTC camera to be turned on/off and have its presets utilized without interrupting active service.

• White Noise System: One white noise system with a minimum of two white noise speakers mounted on the outside of each door, wired safely in/thru wall with the ability to turn on and off from inside the room. The volume level to the white noise is adjustable from inside the room, if able to automate into AV system. No Bluetooth, wireless, or Wi-Fi system/speaker exist or are allowed.

3.4. Cabling and Installation

• The contractor shall provide all cables, connectors, power strips, power supplies, and miscellaneous materials required for a complete installation. All wiring at the A/V desk must be professionally managed and bundled.

4.0 Contractor Deliverables

• System Documentation: The contractor shall produce and develop supporting documentation, diagrams, and artifacts for all system modifications and replacements.

• Source Code: Uncompiled CRESTRON source code shall be delivered in a DISC to the Government. (It should be uncompiled so that it can be edited in the future if you ever need to get the system updated with new components or add a capability like secure VTC etc.)

• Diagrams: Signal flow diagrams (for Audio, Video, and Control) and wiring schematics shall be provided in both PDF and large-format prints. All equipment and wiring must be clearly labeled. (Signal flow diagrams should include separate sheets for 1) AUDIO 2) VIDEO 3) CONTROL Coding (raw code). Wiring Schematics- Label equipment and wiring.

• Equipment Disposal: The contractor is responsible for the removal and disposal of all broken, unserviceable, or replaced components.

• Purchase and Install: All new equipment included as needed after receiving approval from the Government representative. The government will need to be informed if any equipment is backordered or will not arrive on time for installation.

• Training: The contractor shall provide training and orientation for at least two Government individuals on the use of all new equipment and system functionalities.

6.0 Period of Performance and Warranty

• Period of Performance: The contract PoP will be 180 days, commencing promptly after award.

• System Warranty: If replacement equipment or hardware is required, the contractor shall provide a one-year warranty on all equipment and systems installed, effective from the date of installation. This warranty applies to the base year and all exercised option years.

Appendix A: Current Equipment Inventory The following is a non-exhaustive list of equipment currently installed in the VTC/AV system.

The contractor is responsible for maintaining or replacing this equipment to meet the requirements of this SOW. Equipment is not required to be brand name, but must be equal in quality, function, compatibility with the overarching system, and meet the security standards set out in Section 2.0.

Approximate room 203 specifications:19’10” by 23’8”.

Item Item

ACE tower computer 7ft CAT6 SNAGLESS PATCH CBL BLUE

Viewsonic LCD 32inch 7ft CAT6 SNAGLESS PATCH CBL RED

Viewsonic IR REMOTE 7ft CAT6 SNAGLESS PATCH CBL ORNG

NEC class/unclass LCD CAT5E RJ45 MOD INLINE COUPLER

NEC signal boxes 3ft CAT6 SNAGLESS PATCH CBL BLUE

TACLANE 14ft CAT6 SNAGLESS PATCH CBL BLUE

Shure MXA910WH (discontinued) SMALL STATIC MOUNT 100X100

Video cabling (e.g., HDMI) K1 DESK MNT SINGLE DISPLAY 2L ARM BLK

NEC C981Q LED Front LCD XTM1/XSM1 FUSION WALL PLATE

QSC NC-20x60 PTZ cam Micro-Adjust Tilt Wall Mount X-Large

Cisco Precision 60 PTZ Cisco SX80 Codec, Precision 60 Cam, Touch 10

Dell laptop Latitude 5430 3-Series Control System

Crestron TP TSW1060NCBS Tabletop Kit for TSW-1060, Black Smooth

Crestron TP TSD2220B Digital Graphics Engine 100

Crestron AV# 3-series 21.5” HD Touch Screen Display, Black

CISCO SX80 codec Digital Graphics Engine 200 w/PinPoint™ UX & 4K DM 8G+® Input

Freeport SCC5 Net Ext panel 10.1” Touch Screen without Camera, Microphone, or PinPoint™

Freeport SCC5 Network switch MBU 125

Freeport SCC see FPMDVNS2ip HDMI Ultra 6' (1.8 m)

Freeport SCC see FPMDVNS2ip HDMI Ultra 12' (3.6 m)

Freeport RCI FPRCI1 DVC RGB-HD A

Secure switch fiber optic R B MVGA-A M-M 6' (1.8 m)

QSC core 110F 24 audio channels PS 1215 C 12VDC, 1.5A

Netgear M250 26G4XF POE+ DPM-HDF 4K PLUS

Netgear AV line M4250-10G2XF- Custom XTP II CrossPoint 1600

Extron XTP crosspoint 1600 XTP FT HD 4K MM

Extron AC XTP SFR HD 4K MM

Extron SMD702 70v amp HFX 100 Transmitter

Extron power amp XPA 2002 HFX 100 Receiver

GEIST power unit Media Player (Classified / Un Classified)

Extron HFX 100 Transmitter XPA 2002-70V, Amplifier

Extron HFX 100 Receiver Freeport Room Controller Isolator (RCI)

Extron XTP SFR HD 4k MM 2 Network IP MD-VNS System includes SCC5- Net Switch 2 SCC

Extron XTP SFR HD 4k MM Media Converter Package

Extron XTP SFR HD 4k MM Maint. Expansion Panel

Extron XTP SFR HD 4k MM Control 26C with Transformer. For use on a 70.7V or 100V D

NEC E221N-BK 21in AH-IPS LED 1SP UM SHELF,11.5"D, KIT

NEC E221N-BK 21in AH-IPS LED 1SP UM SHELF,11.5"D

JBL control26CT w/transformer CABINET COOL SYSTEM

Freeport FPMCG 16SP, CABINET FRAME RK,18D

Freeport FPMDVNSMEP 18"BOTTOM RUNNER SET

UPS Middle Atlantic 2200r 1SP UM SHELF,11.5"D, KIT

CFR Cabinet Frame Rack 16-18 MultiSync C981Q - 98” Slim LED LCD Public Display Monitor, 3

General Dynamics Taclane MultiSync E221N-BK, 21.5" AH-IPS LED backlit LCD Monitor

2M VS HIGH SPEED W/ETHERNET HDMI

CBL

8-Port Gigabit Switch, Managed, 4 ports PoE+, w/ one 1G

SFP

QSC core 110F Unified Core with 24 local audio I/O channels, 128x128 network

Shure MXA910WH Ceiling Array Microphone (White)x2

File details come from the government source that posted it. Updated .