About this file
GSA Request for Lease Proposals No. 36C24W26R0045 – Las Vegas, Nevada
This is a General Services Administration (GSA) Request for Lease Proposals (RLP) for warehouse space in Las Vegas, Nevada, on behalf of the Department of Veterans Affairs (VA). The Government seeks to lease a minimum of 60,000 to a maximum of 75,700 square feet of contiguous space on a single floor in a modern warehouse building within a defined area of consideration in Las Vegas. The space must include a minimum of 7,125 ABOA (Occupant Area) square feet of office and related space, with a minimum clear ceiling height of 30 feet. Specific physical requirements include bay width of 52 feet, bay depth of 60 feet, column spacing of at least 52 feet, and 12 loading docks measuring 10 feet tall with 200 square feet each. The Government requires 75 to 90 parking spaces, including five reserved spaces, all secured and lit. The lease term is 20 years with 10 years firm, after which the Government has termination rights in whole or in part upon 90 days' notice. Offers are due by 5:00 PM PDT on November 30, 2026, submitted via email to JohnPaul.Niega@va.gov, LeAnne.Jett@va.gov, and Nick@rangesd.com. The planned use is for bulk warehouse storage of general commodities, equipment, prosthetics/medical supplies, and associated receiving dock and staging functions, with potential hazardous materials requiring compliance with federal, state, and local environmental regulations.
The lease is fully serviced with a Tenant Improvement (TI) allowance of $25.00 per ABOA square foot. Offerors must provide pricing on GSA Form 1364WH and GSA Form 1217, clearly itemizing building shell rental, TI rate, Building Specific Amortized Capital (BSAC) rate, operating costs, and parking. All building improvements, lobbies, common areas, and core areas must be provided by the Lessor at the Lessor's expense. The Government will evaluate offers based on six equally-weighted technical factors (space layout and efficiency, site quality and location, parking layout and flexibility, maintenance and service response, past performance, and price) with technical factors significantly more important than price. Additional compliance requirements include ENERGY STAR certification or equivalent, seismic safety compliance per RP 8 standards, fire protection and life safety certifications, accessibility compliance, no asbestos-containing materials, flood plain avoidance, and environmental compliance. The offer must include scaled floor plans, parking plans, construction schedules, proof of financing or financial resources, SAM registration, proof of signing authority, and various other supporting documentation. There is no small business set-aside indicated for this procurement.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GSA TEMPLATE R101WH (07/20/2026)
GSA REQUEST FOR LEASE PROPOSALS
NO. 36C24W26R0045 Las Vegas, Nevada This Request for Lease Proposals ("RLP") sets forth instructions and requirements for proposals for a Lease described in the RLP documents. Proposals conforming to the RLP requirements will be evaluated in accordance with the Method of Award set forth herein to select an Offeror for award. The Government will award the Lease to the selected Offeror, subject to the conditions herein.
Offers due by 11/30/2026
In order to be considered for award, offers conforming to the requirements of the RLP must be received no later than 4:00 pm PST on the date above. See “Receipt Of Lease Proposals” herein for additional information.
The information collection requirements contained in this Solicitation/Contract, that are not required by regulation, have been approved by the Office of Management and Budget pursuant to the Paperwork Reduction Act and assigned the OMB Control No.
3090-0086.
GSA TEMPLATE R101WH (5/25)
TABLE OF CONTENTS
SECTION 1 STATEMENT OF REQUIREMENTS
1.01 GENERAL INFORMATION (WAREHOUSE) (JUL 2026)
1.02 AMOUNT AND TYPE OF SPACE, LEASE TERM, AND OCCUPANCY DATE (WAREHOUSE) (JUL 2026)
1.03 UNIQUE REQUIREMENTS (OCT 2021)
1.04 AREA OF CONSIDERATION (OCT 2021)
1.05 PARKING (WAREHOUSE) (JUL 2026)
1.06 LIST OF RLP DOCUMENTS (WAREHOUSE) (JUL 2026)
1.07 AMENDMENTS TO THE RLP (JUN 2012)
1.08 LEASE DESCRIPTION (WAREHOUSE) (JUL 2026)
1.09 RELATIONSHIP OF RLP BUILDING MINIMUM REQUIREMENTS AND LEASE OBLIGATIONS (OCT 2016)
1.10 PRICING OF SECURITY REQUIREMENTS (JUL 2026)
1.11 SECURITY LEVEL DETERMINATION FOR FACILITY HOUSING OTHER FEDERAL TENANTS (APR 2011)
1.12 AUTHORIZED REPRESENTATIVES (JUL 2026)
1.13 PLANNED USE BY GOVERNMENT (WAREHOUSE) (JUL 2026)
1.14 NORTH AMERICAN INDUSTRY CLASSIFICATION SYSTEM (NAICS) CODE AND SMALL BUSINESS SIZE
STANDARD (OCT 2023)
SECTION 2 ELIGIBILITY AND PREFERENCES FOR AWARD
2.01 EFFICIENCY OF LAYOUT (WAREHOUSE) (MAY 2014)
2.02 FLOOD PLAINS (JUL 2026)
2.03 INTENTIONALLY DELETED
2.04 SEISMIC SAFETY–—HIGH SEISMICITY (MAY 2025)
2.05 ASBESTOS (JUL 2026)
2.06 ACCESSIBILITY (SEP 2013)
2.07 FIRE PROTECTION AND LIFE SAFETY (SEP 2013)
2.08 ENERGY INDEPENDENCE AND SECURITY ACT (JUL 2026)
2.09 ENVIRONMENTAL CONSIDERATIONS (SEP 2013)
2.10 INTENTIONALLY DELETED
2.11 INTENTIONALLY DELETED
SECTION 3 HOW TO OFFER
3.01 GENERAL INSTRUCTIONS (JUL 2026)
3.02 RECEIPT OF LEASE PROPOSALS (SMALL) (JUL 2026)
3.03 PRICING TERMS (WAREHOUSE) (JUL 2026)
3.04 BUDGET SCOREKEEPING; OPERATING LEASE TREATMENT (APR 2011)
3.05 TENANT IMPROVEMENTS INCLUDED IN OFFER (WAREHOUSE) (JUL 2026)
3.06 INTENTIONALLY DELETED
3.07 OPERATING COSTS REQUIREMENTS INCLUDED IN OFFER (JUL 2026)
3.08 INTENTIONALLY DELETED
SECTION 4 METHOD OF AWARD
4.01 NEGOTIATIONS (JUL 2026)
4.02 HUBZONE SMALL BUSINESS CONCERN ADDITIONAL PERFORMANCE REQUIREMENTS (OCT 2023)
4.03 AWARD BASIS (JUL 2026)
4.04 INTENTIONALLY DELETED
4.05 PRESENT VALUE PRICE EVALUATION—WAREHOUSE SQUARE FOOT METHOD (JUL 2026)
4.06 AWARD (JUL 2026)
SECTION 5 ADDITIONAL TERMS AND CONDITIONS
5.01 MODIFIED RLP PARAGRAPHS (OCT 2016)
5.02 GSA REFERENCE
5.03 TENANT IMPROVEMENTS
5.04 FIXED RENT OFFERS
5.05 PROPOSAL COSTS
RLP NO. 36C24W26R0045, PAGE 1 GSA TEMPLATE R101WH (5/25)
SECTION 1 STATEMENT OF REQUIREMENTS
1.01 GENERAL INFORMATION (WAREHOUSE) (JUL 2026)
A. This Request for Lease Proposals (RLP) sets forth instructions and requirements for proposals for a Warehouse Lease described in the RLP documents. The Government will select an Offeror for award by evaluating proposals conforming to the RLP requirements in accordance with the Method of Award set forth below. The Government will award the Lease to the selected Offeror, subject to the conditions below.
B. The RLP documents include a lease template setting forth the terms and conditions of the Lease contemplated by this RLP. The RLP documents include a GSA Proposal to Lease Space (GSA Form 1364WH) on which Offeror must submit its offered rent and other price data, together with required information and submissions. The Lease paragraph titled "Definitions and General Terms" must apply to the terms of this RLP.
C. Offeror should not attempt to complete the lease template. Upon selection for award, VA will transcribe the successful Offeror's final offered rent and other price data as provided by Offeror in its GSA Form 1364WH into the GSA Form L201WH lease template, creating a completed Lease.
VA will transmit the completed Lease, including any appropriate attachments, to the successful Offeror for execution. Neither the RLP nor any other part of an Offeror's proposal must be part of the Lease except to the extent expressly incorporated therein. The Offeror should review the completed Lease for accuracy and consistency with his or her proposal, sign and date the signature page, initial each page of the Lease, and return it to the Lease Contracting Officer (LCO).
D. The Offeror's executed Lease must constitute a firm offer. The Lease is not a binding contract until the LCO executes the Lease and delivers a signed copy to the Offeror.
E. Offeror may not use Federal agency name(s) and/or acronym(s), e.g., General Services Administration, GSA, in the entity name that owns and/or leases the Space to VA. action required: leasing specialist to input the required ABOA SF
1.02 AMOUNT AND TYPE OF SPACE, LEASE TERM, AND OCCUPANCY DATE (WAREHOUSE) (JUL 2026)
A. The Government seeks a minimum of 60,000 to a maximum of 75,700 square feet of contiguous space on a single floor in a warehouse type building. The required space is to be measured and offered by Offerors in square feet in accordance with American National Standards Institute/Building Owners and Managers Association (ANSI/BOMA) Occupant Area (ABOA) square feet (SF), (hereinafter referred to as “ANSI/BOMA ABOA SF” or “ABOA SF”) of contiguous space within the area of consideration set forth below. Mezzanines are excluded from the area calculation of the size of the space. See section 2 of the lease for applicable ANSI/BOMA standards. The required space must be contiguous space located all on ground level. Also see Section 4 of this RLP for details on the calculation of the Present Value Price Evaluation– —Warehouse Square Foot Method that will determine the lowest priced offer. The space must have a minimum clear ceiling height 30 feet, 0 inches.
B. The space must be located in a modern quality building of sound and substantial construction in good condition and acceptable to the LCO. If not a new building, the offered space must be in a building that has undergone, or will complete by occupancy, modernization or adaptive reuse for the space in conformance with this RLP and the associated documents either attached to or incorporated by reference (and itemized in the paragraph entitled “List Of RLP Documents”). Unless specifically stated as tenant improvements (TI), the Lessor must perform all work at Lessor’s sole cost and expense.
C. Bay Width, Bay Depth, and Column Spacing.
1. Bay Width: 52’ 0” (the distance from one side of the bay to the other side of the bay in linear feet and inches)
2. Bay Depth: 60’ 0” (the distance from the front of the bay to the back of the bay in linear feet and inches)
3. Column Spacing: Columns must be at least 52’ 0” linear feet apart, measured from the nearest surface of each.
D. Floors and Floor Load. See lease Paragraph entitled FLOORS AND FLOOR LOAD–—SHELL (WAREHOUSE) in Section 3 of the Lease.
E. Automobile Parking: The government seeks a minimum 75 to a maximum of 90 parking spaces for automobiles, 5 of which must be marked as reserved for the exclusive use of the Government. All spaces must be secured and lit in accordance with the Security Requirements set forth in this Lease. The cost of this parking must be included as part of the rental consideration.
F. INTENTIONALLY DELETED
G. Delivery Route. At least one unobstructed route at least 36 inches wide having no steps or abrupt changes in level to connect all accessible elements, spaces, buildings, and courses of passage.
H. Loading Docks. (Also see the “LOADING DOCKS—SHELL (WAREHOUSE)” paragraph in Section 3 of the lease form).
Lessor must provide a minimum of 12 loading dock(s) for the exclusive use of the Government. The dock height and configuration must be 10 feet tall with a total area of 200 square feet each. All dock doors must include electronic openers as a part of Shell Rent unless otherwise specified in the Agency Special Requirements. Any other upgrades (e.g., security enhancements) to the dock doors must be considered to be Tenant Improvements.
I. Truck Turning Radius. At a minimum, a truck turning radius of 125 feet sized for WB-62 for all loading docks designed for such sized trucks.
One-way design for service traffic is preferred in order to avoid the need for large turning areas.
J. INTENTIONALLY DELETED
RLP NO. 36C24W26R0045, PAGE 2 GSA TEMPLATE R101WH (07/20/2026)
K. INTENTIONALLY DELETED
L. The Government may provide vending machines within the Government's leased area under the provisions of the Randolph-Sheppard Act (20 USC 107 et. seq.). The Government will control the number, kind, and locations of vending facilities and will control and receive income from all automatic vending machines. Offeror must provide necessary utilities and make related alterations. The cost of the improvements is part of Tenant Improvement (TI) costs. The Government will not compete with other facilities having exclusive rights in the Building. The Offeror must advise the Government if such rights exist.
M. 20 Years, 10 Years Firm, with Government termination rights, in whole or in parts, effective at any time after the Firm Term of the Lease by providing not less than 90 days’ prior written notice.
N. Occupancy is required in accordance with the schedule outlined in the Schedule for Completion of Space paragraph under the Lease.
O. See loading dock requirements and other requirements in Section 3 of the Lease.
P. The space requirement identified in subparagraph “A” will include a minimum of 7,125 ABOA SF of office and related space.
1.03 UNIQUE REQUIREMENTS (OCT 2021)
The offered Building and/or Property must have the following features as a minimum requirement:
A. HVAC must be provided for the entire warehouse space and the temperature of this space must be maintained between 66 and 75 degrees Fahrenheit.
B. __________ C. __________
1.04 AREA OF CONSIDERATION (Oct 2021)
The Government requests offers of space in the area bounded as follows:
North: Beginning at the intersection of Speedway Blvd and N Hollywood Blvd, continuing on Speedway Blvd past E N Belt Rd to the intersection of Range Rd and I-215 N (Bruce Woodbury Beltway), continuing on I-215 N (Bruce Woodbury Beltway) and ending at the intersection of I-215 N (Bruce Woodbury Beltway) and N 5th St.
South: Beginning at the intersection of N 5th St and E Cheyenne Ave, continuing to the intersection of E Cheyenne Ave and Civic Center Dr, continuing on Civic Center Dr as it becomes E Alexander Rd, continuing onto Puebla St and Las Vegas Blvd N and ending at the intersection of Las Vegas Blvd N and N Hollywood Blvd.
East: Beginning at the intersection of Las Vegas Blvd N and N Hollywood Blvd, continuing on N Hollywood Blvd, and ending at the intersection with Speedway Blvd.
West: Beginning at the intersection of I-215 N (Bruce Woodbury Beltway) and N 5th St, continuing along N 5th St, and ending at the intersection with E Cheyenne Ave.
Buildings with Property boundary(ies) on the boundary streets are within the delineated Area of Consideration.
1.05 PARKING (WAREHOUSE) (JUL 2026)
A. INTENTIONALLY DELETED
B. INTENTIONALLY DELETED
C. See Lease (GSA Form L201WH) for additional parking provisions.
RLP NO. 36C24W26R0045, PAGE 3 GSA TEMPLATE R101WH (07/20/2026)
1.07 LIST OF RLP DOCUMENTS (WAREHOUSE) (JUL 2026)
A. The following documents are attached to and included as part of this RLP package:
DOCUMENT NAME NO. OF PAGES EXHIBIT
Lease No. 36C24W26L0052 (Template L201WH) 39 A
Agency’s Special Requirements 87 B
Security Requirements for Level II 9 C
GSA 3516, Solicitation Provisions 8 D
GSA 3517B, General Clauses 33 E
Proposal to Lease Space (GSA Form 1364WH) 5 F
GSA Form 1217, Lessor's Annual Cost Statement 3 G
GSA Form 12000-WH for Prelease Fire Protection and Life Safety Evaluation for a Warehouse Building (Part A or Part B) (See Section 3 for applicable requirements)
6 H
Seismic Offer Forms 8 I
DOL Wage Determination 13 J
FAR 52.204-24, Representation Regarding Certain Telecommunications and Video Surveillance Services or Equipment
4 K
Broker Project Exhibit 1 L
B. INTENTIONALLY DELETED
1.08 AMENDMENTS TO THE RLP (JUN 2012)
This RLP may be amended by notice from the LCO. Amendments may modify the terms of this RLP, or the terms, conditions, and requirements of the Lease contemplated by the RLP.
1.09 LEASE DESCRIPTION (WAREHOUSE) (JUL 2026)
A. Offeror must examine the Lease template included in the RLP documents to understand the Government's and the Lessor's respective rights and responsibilities under the contemplated Lease.
B. The Lease contemplated by this RLP includes:
1. The term of the Lease, and renewal option, if any.
2. Terms and Conditions of the Lease, including Definitions, Standards, and Formulas applicable to the Lease and this RLP.
3. Building Shell standards and requirements.
4. Information concerning the tenant agency's buildout requirements (“Special Requirements”), to be supplemented after award.
5. Security Requirements.
6. A description of all services to be provided by the Lessor.
C. Should the Offeror be awarded the Lease, the terms of the Lease must be binding upon the Lessor without regard to any statements contained in this RLP.
D. The Lease contemplated by this RLP is a fully serviced Lease. See RLP Paragraphs 3.03 and 3.07 for further details on financial responsibility for various Operating Expenses. Rent must be based upon a proposed rental rate per Rentable Square Foot (RSF), limited by the offered rate and the maximum ABOA SF solicited under this RLP. Although certain Tenant Improvement (TI) requirements information is provided with this RLP and will be incorporated into the Lease, the TIs to be delivered by the Lessor will be based on the final design to be developed after award of the Lease, which reflects the Agency’s full requirements. The Lessor must design and build the TIs and will be compensated for TI costs, together with design and project management fees to be set under the Lease. Although the TI requirements will not be developed fully until after award, Offerors must provide the allowance stated in the Tenant Improvement Allowance paragraph of the Lease.
E. Unless the Government prepares Design Intent Drawings (DIDs), after award the Lessor must prepare DIDs for the leased Space conforming to the lease requirements and other Government-supplied information related to the client agency’s interior build-out requirements. The Government will have the opportunity to review the Lessor's DIDs to determine that the Lessor's design meets the requirements of the Lease.
Only after the Government approves the DIDs and a final price for TIs is negotiated will the Lessor be released to proceed with buildout. The Lease also provides that the Government may modify the TI requirements, subject to the Lessor's right to receive compensation for such changes.
F. The security pricing process is described in a separate paragraph.
RLP NO. 36C24W26R0045, PAGE 4 GSA TEMPLATE R101WH (07/20/2026)
G. Upon completion and acceptance of the leased Space, the Space will be measured for establishing the actual annual rent, and the lease term must commence. In instances involving an incumbent Lessor where the Government commences the lease term pending completion of TI and/or BSAC alterations, the Government must withhold TI and/or BSAC rent pursuant to Section 1 of the Lease until such time as the TI and/or BSAC is completed and accepted by the Government. During the term of the Lease, rent will be adjusted for changes to the Lessor's operating costs and real estate taxes, pursuant to paragraphs set forth in the Lease.
H. Offerors are advised that doing business with the Government carries special responsibilities with respect to sustainability, fire protection and life safety, and security, as well as other requirements not typically found in private commercial leases. These are set forth both in the lease form and in the GSA 3517B, General Clauses and will be made part of the Lease.
1.10 RELATIONSHIP OF RLP BUILDING MINIMUM REQUIREMENTS AND LEASE OBLIGATIONS (OCT 2016)
The Lease establishes various requirements relating to the Building shell. Such requirements are not deemed TIs. There are certain Building requirements that are established as minimum requirements in this RLP. If the Lessor's Building does not meet the requirements at the time of award, the Lessor may still be awarded the Lease. However, as a condition of award, the Government will require Lessor to identify those Building improvements that will bring the Building into compliance with RLP requirements. Upon award of the Lease, completion of those Building improvements will become Lease obligations.
1.11 PRICING OF SECURITY REQUIREMENTS (JUL 2026)
A. The proposed Lease contains an attachment with the security requirements and obligations for the Building, which are based on the facility security level (FSL). The Federal Government determines the facility’s FSL rating, which ranges from FSL I to FSL IV. The FSL is based on client agency mix, required size of space, number of employees, use of the space, location, configuration of the site and lot, and public access into and around the facility.
B. INTENTIONALLY DELETED
C. There must be no charge to the Government for any items that already exist in the offered Building or facility.
1.12 SECURITY LEVEL DETERMINATION FOR FACILITY HOUSING OTHER FEDERAL TENANTS (APR 2011)
If an Offeror is offering Space in a facility currently housing a Federal agency, the security requirements of the facility may be increased and the Offeror may be required to adhere to a higher security standard than other Offerors competing for the same space requirement. If two or more Federal space requirements are being competed at the same time, an Offeror submitting on both or more space requirements may be subject to a higher security standard if the Offeror is determined to be the successful Offeror on more than one space requirement. It is incumbent upon the Offeror to prepare the Offeror’s proposal accordingly.
1.13 AUTHORIZED REPRESENTATIVES (JUL 2026)
With respect to all matters relating to this RLP, only the Government's LCO designated below must have the authority to amend the RLP and award a Lease. The Government must have the right to substitute its LCO by notice, without an express delegation by the prior LCO.
Lease LCO:
John Paul Niega
(775) 389-6616 JohnPaul.Niega@va.gov
As to all other matters, Offerors may contact the Alternate Government Contact designated below.
Alternate Government Contact:
LeAnne Jett
(916) 640-8426 LeAnne.Jett@va.gov
1.14 PLANNED USE BY GOVERNMENT (WAREHOUSE) (JUL 2026)
The Government must be entitled to use the space for any lawful purpose. However, the Government intends to initially use the space for bulk warehouse storage of general commodities, equipment, and prosthetics/medical supplies, including segregated storage of full and empty gas cylinders and flammable materials, with associated receiving dock, breakdown, and equipment prep/staging functions. Basic racking heights should be 20’ tall, 8’ wide and, 4’ deep minimum. Pallet types should be wood and plastic. Such use may involve the use of hazardous materials. The Government will agree in the Lease to use and maintain any hazardous materials in conformance with all applicable Federal, state, and local environmental regulations.
1.15 NORTH AMERICAN INDUSTRY CLASSIFICATION SYSTEM (NAICS) CODE AND SMALL BUSINESS SIZE STANDARD (OCT 2023)
A. The North American Industry Classification System (NAICS) code for this acquisition is 531120 (Exception).
B. The small business size standard for the applicable NAICS codes is found at HTTPS://WWW.SBA.GOV/DOCUMENT/SUPPORT-TABLE-SIZE-
STANDARDS.
https://www.sba.gov/document/support-table-size-standards
RLP NO. 36C24W26R0045, PAGE 5 GSA TEMPLATE R101WH (07/20/2026)
SECTION 2 ELIGIBILITY AND PREFERENCES FOR AWARD
2.01 EFFICIENCY OF LAYOUT (WAREHOUSE) (MAY 2014)
A. In order to be acceptable for award, the offered Space must provide for an efficient layout as determined by the LCO.
B. To demonstrate potential for efficient layout, GSA may request the Offeror to provide a test fit layout at the Offeror’s expense. The Government will advise the Offeror if the test fit layout demonstrates that the Government's requirement cannot be accommodated within the Space offered.
The Offeror will have the option of increasing the ABOA square footage offered if it does not exceed the maximum ABOA square footage in this RLP offer package. If the Offeror is already providing the maximum ABOA square footage and cannot house the Government's space requirements efficiently, then the Government will advise the Offeror that the offer is unacceptable.
C. Space offered must have a minimum column spacing of 52 feet 0 inches, an overall minimum width of 52 feet 0 inches, and an overall minimum depth of 60 feet 0 inches.
2.02 FLOOD PLAINS (JUL 2026)
A Lease will not be awarded for any offered Property located within a 1-percent-annual-chance floodplain (formerly referred to as 100-year floodplain) unless the Government has determined that there is no practicable alternative. An Offeror may offer less than its entire site in order to exclude a portion of the site that falls within a floodplain, so long as the portion offered meets all the requirements of this RLP and does not impact the Government’s full use and enjoyment of the Premises. If an Offeror intends that the offered Property that will become the Premises for purposes of this Lease will be something other than the entire site as recorded in tax or other property records the Offeror must clearly demarcate the offered Property on its site plan/map submissions and must propose an adjustment to property taxes on an appropriate pro rata basis. For such an offer, the Government may determine that the offered Property does not adequately avoid development in a 1-percent-annual-chance floodplain.
In addition, a Lease will not be awarded for any offered Property adjacent to a 1-percent-annual-chance floodplain, where such an adjacency would, as determined by the Government, restrict ingress or egress to the Premises in the event of a flood, unless there is no practicable alternative.
2.03 INTENTIONALLY DELETED
2.04 SEISMIC SAFETY–—HIGH SEISMICITY (MAY 2025)
In accordance with the Earthquake Hazards Reduction Act of 1977, the following apply:
A. The Government intends to award a Lease to an Offeror of a Building that is in compliance with the Seismic Standards. If an offer is received which is in compliance with the Seismic Standards and the other requirements of this RLP, then other offers which do not comply with the Seismic Standards must not be considered. If none of the offers is in compliance with the Standards, the LCO will make the award to the Offeror whose
RLP NO. 36C24W26R0045, PAGE 6 GSA TEMPLATE R101WH (07/20/2026)
offer meets the other requirements of this RLP and provides the best value to the Government, taking into account price, seismic safety and any other evaluation factors specified in this RLP.
B. An offered Building will be considered to be in compliance with the Seismic Standards if it meets one of the following condit ions:
1. The offer includes a representation that the Premises will be in a one-story Building of steel light frame or wood construction with less than 3,000 ABOA SF of space in the Building (Seismic Form D).
2. The offer includes a Seismic Certificate certifying that the Building is a Benchmark Building (Seismic Form A).
3. The offer includes a Seismic Certificate based on a Tier I Evaluation showing that the Building meets the Seismic Standards (Seismic Form B). The submission must include the checklists and backup calculations from the Tier 1 Evaluation.
4. The offer includes a Seismic Certificate based on a Tier 2 or Tier 3 Evaluation showing that the Building complies with the Seismic Standards (Seismic Form B). If the certificate is based on a Tier 2 or Tier 3 Evaluation, the data, working papers, calculations and reports from the evaluation must be made available to the Government.
5. The offer includes a commitment to retrofit the Building to satisfy all of the Basic Safety Objective requirements of ASCE/SEI 41 (Seismic Form C, Part 1). If the Offeror proposes to retrofit the Building, the offer must include a Tier 1 report with all supporting documents, a narrative explaining the process and scope of retrofit and a schedule for the seismic retrofit. The Offeror must provide a construction schedule, concept design for the seismic upgrade and supporting documents for the retrofit, including structural calculations, drawings, specifications, and geotechnical report to the Government for review and approval prior to award. The documentation must demonstrate the seismic retrofit will meet the seismic standards and be completed within the time frame required.
6. The offer includes a pre-award commitment to construct a new Building, using local building codes (Seismic Form C, Part 2).
C. The LCO may allow an Offeror to submit a Seismic Certificate after the deadline for final proposal revisions. However, the LCO is not obligated to delay award in order to enable an Offeror to submit a Seismic Certificate.
D. Definitions. For the purpose of this paragraph:
1. “ASCE/SEI 31” means the American Society of Civil Engineers standard, Seismic Evaluation of Existing Buildings. You can purchase ASCE/SEI from ASCE at (800) 548-2723 or by visiting HTTP://WWW.ASCE.ORG/PUBLICATIONS/.
2. “ASCE/SEI 41” means American Society of Civil Engineers standard, Seismic Rehabilitation of Existing Buildings. You can purchase ASCE/SEI from ASCE at (800) 548-2723 or by visiting HTTP://WWW.ASCE.ORG/PUBLICATIONS/.
1. “Benchmark Building” means a building that was designed and built, or retrofitted, in accordance with the seismic provisions of the applicable codes specified in Section 1.3.1 of RP 8.
2. Engineer” means a professional engineer who is licensed in Civil or Structural Engineering and qualified in the structural design of buildings. They must be licensed in the state where the property is located.
3. “RP 8” means “Standards of Seismic Safety for Existing Federally Owned and Leased Buildings ICSSC Recommended Practice 8 (RP 8),” issued by the Interagency Committee on Seismic Safety in Construction as ICSSC RP 8 and the National Institute of Standards and Technology as NIST GCR 11-917-12. RP 8 can be obtained from HTTPS://WWW.NIST.GOV/PUBLICATIONS/.
4. “Seismic Certificate” means a certificate executed and stamped by an Engineer on the appropriate Certificate of Seismic Compl iance form included with this RLP together with any required attachments.
5. “Seismic Standards” means the requirements of RP 8 Section 2.2 for Life Safety Performance Level in ASCE/SEI 31 or the Basic Safety Objective in ASCE/SEI 41, unless otherwise specified.
6. “Tier 1 Evaluation” means an evaluation by an Engineer in accordance with Chapters 2.0 and 3.0 of ASCE/SEI 31. A Tier 1 Evaluation must include the appropriate Structural, Nonstructural and Geologic Site Hazards and Foundation Checklists.
7. “Tier 2 Evaluation” means an evaluation by an Engineer in accordance with Chapter 4.0 of ASCE/SEI 31.
8. “Tier 3 Evaluation” means an evaluation by an Engineer in accordance with Chapter 5.0 of ASCE/SEI 31.
2.05 ASBESTOS (JUL 2026)
A. The Government requires space with no asbestos-containing materials (ACM), or with undamaged, nonfriable ACM. For purposes of this paragraph, “space” includes the 1) space offered for lease; 2) common building area; 3) ventilation systems and zones serving the space offered;
and 4) the area above suspended ceilings and engineering space in the same ventilation zone as the space offered. Notwithstanding the preceding, if no offers are received for such space, the Government may consider space with thermal system insulation ACM (e.g., wrapped pipe or boiler lagging), which is not damaged or subject to damage by routine operations.
B. ACM is defined as any material with a trace or more of asbestos quantity present.
C. Space with ACM of any type or condition may be upgraded by the Offeror to meet conditions described in sub-paragraph A by abatement (removal, enclosure, encapsulation, or repair) of ACM not meeting those conditions. If any offer involving abatement of ACM is accepted by the Government, the successful Offeror will be required to successfully complete the abatement in accordance with OSHA (29 CFR § 1910.1001, http://www.asce.org/publications/ http://www.asce.org/publications/ https://www.nist.gov/publications/standards-seismic-safety-existing-federally-owned-and-leased-buildings-icssc
RLP NO. 36C24W26R0045, PAGE 7 GSA TEMPLATE R101WH (07/20/2026)
29 CFR § 1926.1101), EPA (40 CFR Part 61 - National Emission Standards for Hazardous Air Pollutants and Part 763), state, and local regulations and guidance prior to occupancy.
D. Management Plan and Reinspection Report Submittals. If space is offered which contains ACM, the Offeror must submit a current asbestos-related management plan or operations and maintenance plan, along with a current asbestos re-inspection report (performed within the past 5 years) that includes a list of all ACM and their condition for acceptance by the Government prior to lease award. The management plan or operations and maintenance plan, and re-inspection report must conform to generally accepted industry practice in accordance with OSHA (29 CFR § 1910.1001, 29 CFR § 1926.1101), EPA (40 CFR Part 61 - National Emission Standards for Hazardous Air Pollutants and Part 763).
E. The Government reserves the right to review Offeror’s existing records for compliance.
2.06 ACCESSIBILITY (SEP 2013)
The Lease contemplated by this RLP contains requirements for Accessibility. In order to be eligible for award, Offeror must either:
A. Verify in the Lease proposal that the Building, offered Space, and areas serving the offered Space meet the Lease accessibility requirements, or
B. Include as a specific obligation in its Lease proposal that improvements to bring the Building, offered Space, and areas serving the offered Space into compliance with Lease accessibility requirements will be completed prior to acceptance of the Space.
2.07 FIRE PROTECTION AND LIFE SAFETY (SEP 2013)
The Lease contemplated by this RLP contains Building requirements for Means of Egress, Automatic Fire Sprinkler System, and Fire Alarm System. In order to be eligible for award, Offeror must either:
A. Verify in the Lease proposal that the Building in which Space is offered meets the Means of Egress, Automatic Fire Sprinkler System, and Fire Alarm System requirements of the Lease; or
B. Include as a specific obligation in its Lease proposal that improvements to bring the Building into compliance with Lease requirements will be completed prior to acceptance of the Space.
2.08 ENERGY INDEPENDENCE AND SECURITY ACT (JUL 2026)
A. The Energy Independence and Security Act (EISA) establishes requirements for Government leases relating to energy efficiency standards and potential cost-effective energy efficiency and conservation improvements.
B. Subject to the exceptions below, unless one of the statutory exceptions listed in sub-paragraph C below applies, GSA may award a Lease for a Building only if the Building has earned the ENERGY STAR® label conferred by the U.S. Environmental Protection Agency (EPA) within the most recent year prior to the due date for final proposal revisions. The term “most recent year” means that the date of award of the ENERGY STAR® label by EPA must not be more than 1 year prior to the due date of final proposal revisions. For example, an ENERGY STAR® label awarded by EPA on October 1, 2023, is valid for all lease procurements where final proposal revisions are due on or before September 30, 2024.
Notwithstanding the above, buildings that meet any of the following are considered as equivalent to having an Energy Star label in the most recent year, provided they achieve an ENERGY STAR® label within 18 months after occupancy by the Government:
1. All new Buildings being specifically constructed for the Government, provided they achieve an ENERGY STAR® label within 18 months after occupancy by the Government, and received the “Designed to Earn the Energy Star®” certification prior to construction;
2. All existing Buildings that have had an Energy Star® label but are unable to obtain a label in the most recent year (i.e., within 12 months prior to the due date for final proposal revisions) because of insufficient occupancy;
3. Newly built Buildings that have used Energy® Star’s Target Finder tool and either achieved a “Designed to Earn the Energy Star®” certification or received an unofficial score (in strict adherence to Target Finder’s usage instructions, including the use of required energy modeling) of 75 or higher prior to the due date for final proposal revisions and who are unable to obtain a label in the most recent year because of insufficient occupancy; or
4. An existing Building that is unable to obtain a label because of insufficient occupancy but that can produce an indication, through the use of energy modeling or past utility and occupancy data input into Energy Star’s® Portfolio Manager tool or Target Finder, that it can receive an unofficial score of 75 or higher using all other requirements of Target Finder or Portfolio Manager, except for actual data from the most recent year.
C. Subject to subparagraph D below, EISA allows a Federal agency to lease Space in a Building that does not have an ENERGY STAR® Label if:
1. No Space is offered in a Building with an ENERGY STAR® Label that meets RLP requirements, including locational needs;
2. The agency will remain in a Building it currently occupies;
3. The Lease will be in a Building of historical, architectural, or cultural significance listed or eligible to be listed on the National Register of Historic Places; or
4. The Lease is for 10,000 RSF or less.
RLP NO. 36C24W26R0045, PAGE 8 GSA TEMPLATE R101WH (07/20/2026)
D. If one or more of the statutory exceptions applies, and the offered Space is not in a Building that has earned the ENERGY STAR® Label within one year prior to the due date for final proposal revisions, Offerors are required to include in their lease proposal an agreement to renovate the Building for all energy efficiency and conservation improvements that it has determined would be cost effective over the Firm Term of the Lease, if any, prior to acceptance of the Space (or not later than one year after the Lease Award Date of a succeeding or superseding Lease). Such improvements may consist of, but are not limited to, the following:
1. Heating, Ventilating, and Air Conditioning (HVAC) upgrades, including boilers, chillers, and Building Automation System (BAS)/Monitoring /Control System (EMCS).
2. Lighting Improvements.
3. Building Envelope Modifications.
E. The term "cost effective" means an improvement that will result in substantial operational cost savings to the landlord by reducing electricity or fossil fuel consumption, water, or other utility costs. The term "operational cost savings" means a reduction in operational costs to the landlord through the application of Building improvements that achieve cost savings over the Firm Term of the Lease sufficient to pay the incremental additional costs of making the Building improvements.
F. Instructions for obtaining an ENERGY STAR® Label are provided at ENERGYSTAR.GOV (use “Portfolio Manager” to apply). The ENERGY STAR® BUILDING UPGRADE MANUAL and BUILDING UPGRADE VALUE CALCULATOR are tools which can be useful in considering energy efficiency and conservation improvements to Buildings.
G. If one or more of the statutory exceptions applies, and the offered Space is not in a Building that has earned the ENERGY STAR® Label within one year prior to the due date for final proposal revisions, the successful Offeror will be excused from performing any agreed-to energy efficiency and conservation renovations, and benchmarking with public disclosure (as provided in (I) below, if it obtains the ENERGY STAR® Label prior to the Government’s acceptance of the Space (or not later than one year after the Lease Award Date for succeeding and superseding leases).
H. If no improvements are proposed, the Offeror must demonstrate to the Government using the ENERGY STAR® Online Tools why no energy efficiency and conservation improvements are cost effective. If such explanation is unreasonable, the offer may be rejected.
I. As described in Section 3 of the Lease, successful Offerors meeting one of the statutory exceptions above must agree to benchmark and publicly disclose the Building’s current ENERGY STAR® score, using EPA’s Portfolio Manager online software application. See the Lease for additional details.
J. All new Buildings being specifically constructed for the Government must achieve the ENERGY STAR® Label within 18 months after occupancy by the Government.
2.09 ENVIRONMENTAL CONSIDERATIONS (SEP 2013)
A. The Government requests space with no known hazardous conditions or recognized environmental conditions that would pose a health and safety risk or environmental liability to the Government.
B. Upon request by the Government, Offeror must provide all known previous uses of the Building.
C. Offeror must indicate in its written offer any known hazardous conditions or environmental releases with/from the offered Space, Building or Property.
2.10 INTENTIONALLY DELETED
2.11 INTENTIONALLY DELETED
http://www.energystar.gov/BUILDINGS/FACILITY-OWNERS-AND-MANAGERS/EXISTING-BUILDINGS/EARN-RECOGNITION/ENERGY-STAR-CERTIFICATION http://www.energystar.gov/BUILDINGS/FACILITY-OWNERS-AND-MANAGERS/EXISTING-BUILDINGS/SAVE-ENERGY/COMPREHENSIVE-APPROACH/ENERGY-STAr http://www.energystar.gov/BUILDINGS/TOOLS-AND-RESOURCES/BUILDING-UPGRADE-VALUE-CALCULATOR
RLP NO. 36C24W26R0045, PAGE 9 GSA TEMPLATE R101WH (07/20/2026)
SECTION 3 HOW TO OFFER
3.01 GENERAL INSTRUCTIONS (JUL 2026)
A. Offeror must prepare a complete offer, using the forms provided with this RLP, and submit the completed lease proposal package to the Government as indicated below. The Government will evaluate the offers received as outlined below and further described in this section.
B. Offeror shall also submit with its offer the following:
SUBMITTAL RLP REFERENCE
GSA Form 1364WH—Warehouse Proposal to Lease Space 3.03 B
Lessor’s Annual Cost Statement (GSA Form 1217) 3.03 A
Authorization to Represent Ownership (required if Offeror is not the owner) 3.01 C
Conditional Commitment of Funds 3.01 D
Local Zoning Compliance 3.01 E
Ownership Evidence 3.01 F
Agreement to Acquire an Interest in Property (required if Offeror does not have vested interest in Property) 3.01 G
Signing Authority Proof 3.01 H
Conflict of Interest, if required 3.01 I
SAM Registration 3.01 J
Fire Protection and Life Safety 3.01 K
Legal Property Description and Tax ID 3.01 L
Parking Plan and Narrative, if required 3.01 M
Architectural Plans for Building Modernization, if required 3.01 N
Asbestos Submittals, i.e., management plan, reinspection report, if required 2.05 D
Scaled Floorplan of Offered Space(s) 3.01 O
Test Fit Layout (if requested by GSA) 2.01
Disclosure of any Known Hazardous Conditions or Environmental Releases with/from Offered Space, Building or Property, if required
2.09
Vending Facilities Statement 3.01 P
Amenities Evidence 3.01 Q
Energy Star or Other Efficiency Improvements Supporting Documentation 3.01 R
Evidence of Seismic Compliance 2.03 and/or 2.04
Construction Schedule 3.01 U
Evaluation Factor Submittal Documentation 4.03 C
Small Business Subcontracting Plan, if required for Other Than Small Business above the threshold (FAR 19.109(a)(1) (GSA Class Deviation RFO-2025-19))
1.13 & SAM
Registration
Hourly Overtime HVAC Rates, if applicable L201WH, Paragraph entitled
“HOURLY
OVERTIME HVAC
RATES”
Broker Project Exhibit Submittal(s) Exhibit L: Broker Project
C. Authorization to Represent Ownership. If the offeror is not the owner of the Property, authorization from the ownership entity to submit an offer on the ownership entity’s behalf.
D. Conditional Commitment of Funds. Satisfactory evidence of at least a conditional commitment of funds in an amount necessary to prepare the Space, including Shell, TI, and BSAC improvements. Such commitments shall be signed by an authorized bank officer, or other legally authorized financing official, and at a minimum shall state: amount of loan, term in years, annual percentage rate, and length of loan
RLP NO. 36C24W26R0045, PAGE 10 GSA TEMPLATE R101WH (07/20/2026)
commitment. Alternatively, if the Offeror is self-financing, Offeror must demonstrate, to the satisfaction of the LCO, that it has adequate financial resources to self-finance the necessary improvements, e.g., income statements, cash flow statements, balance sheets, three (3) months of bank statements showing sufficient on hand stable cash reserves to fund the improvements, letter from the entity’s financial officer.
E. Local Zoning Compliance. Evidence that the Property is zoned in compliance with local zoning laws, including evidence of variances, if any, approved by the proper local authority. If the current zoning is not in compliance, the Offeror must submit a plan and time schedule outlining how they will obtain all necessary zoning approvals prior to construction and how long the necessary zoning approvals will take.
F. Ownership Evidence. Evidence of ownership or control of Building or site. If the Offeror owns the Property being offered or has a long-term leasehold interest, the deed or lease must be submitted to the LCO evidencing the Offeror's stated interest in the Property and any encumbrances on the Property.
G. Agreement to Acquire an Interest in Property. If the Offeror does not yet have a vested interest in the Property, but rather has a written agreement to acquire an interest, then the Offeror shall submit a fully executed copy of the written agreement with its offer, together with a statement from the current owner that the agreement is in full force and effect and that the Offeror has performed all conditions precedent to closing, or other form of documentation satisfactory to the LCO prior to award. These submittals must remain current. The Offeror is required to submit updated documents as required.
H. Signing Authority Proof. As a condition of lease award, the Government will require one of the following forms of proof of signing authority before the Government executes the Lease:
1. Corporation. Copy of Articles of Incorporation and bylaws. In addition, a copy of the resolution, signed by the necessary directors of the corporation authorizing the corporate officer who will sign the lease to bind the corporation to the Lease.
2. Partnership. Copy of Partnership Agreement, Statement of Partnership, or Statement of Limited Partnership and evidence of authority of signatory to bind the partnership if not expressly authorized by the Partnership Agreement.
3. Limited Liability Company. Copy of the Articles of Organization and Operating Agreement. Also, evidence of the authority of the signing manager (if company is manager owned) or member (if the company is member managed) to sign, if not expressly authorized by the Articles of Organization and/or Operating Agreement.
4. Joint Venture. Copy of Joint Venture Agreement and evidence of authority of signatory to bind the Joint Venture to the Lease.
I. Conflict of Interest. If there is a potential for conflict of interest because of a single agent representing multiple owners, present evidence that the agent disclosed the multiple representation to each entity and has authorization from each ownership entity offering in response to this RLP package. Owners and agents in conflicting interest situations are advised to exercise due diligence with regard to ethics, independent pricing, and Government procurement integrity requirements. In such cases, the Government reserves the right to negotiate with the owner directly.
J. SAM Registration. The Offeror must have an active registration in the System for Award Management (SAM), via the Internet at HTTPS://WWW.SAM.GOV/SAM/ prior to the Lease Award Date. Offerors must be registered for purposes of “All Awards,” including completion of all required representations and certifications within SAM. This registration service is free of charge.
K. Fire Protection and Life Safety (FPLS). The Offeror must submit the FPLS Information in subparagraph 1, unless the Building meets either exemption in subparagraphs 2 or 3 below.
1. FPLS Submittal Information.
a. Completed GSA Form 12000-WH, Pre-lease Fire Protection and Life Safety Evaluation for a Warehouse Building (Part A or PART B, as applicable). The GSA Form 12000-WH contains two parts that must be completed depending on the area of the space the offeror proposes to lease to the Government. The offeror or an authorized representative must complete Part A when an offered space is less than 40,000 rentable square feet in area. Part A shall be completed by the Offeror or their authorized representative.
Part B must be completed when offered space is greater than or equal to 40,000 rentable square feet in area. The licensed fire protection engineer must complete Part B.
b. A copy of the previous year’s automatic fire sprinkler system maintenance record showing compliance with the requirements in NFPA 25 (if an automatic fire sprinkler system is installed in the Building).
c. A copy of the previous year’s fire alarm system maintenance record showing compliance with the requirements in NFPA 72 (if a fire alarm system is installed in the Building).
d. Scaled floor plan drawings (1/8-inch scale, minimum) of the space offered for government lease, and a floor plan of the building showing locations and dimensions of storage area. All plans submitted for consideration shall include the locations of all exits, aisles, and fire department access doors shall also be identified on the plans. The exits and fire department access doors in place or any proposed exits, aisles, and fire department access doors shall meet local code requirements for issuance of occupancy permits.
e. A valid Building Certificate of Occupancy (C of O) issued by the local jurisdiction. If the Building C of O is not available or the jurisdiction does not issue a Building C of O, provide either:
I. A report prepared by a licensed fire protection engineer with their assessment of the Building regarding compliance with all applicable local Fire Protection and Life Safety related codes and ordinances; or
II. For offers of new construction only, documentation indicating the Building Code (including edition) to which the Building is being constructed and a written commitment to meet all of the mandatory FPLS lease requirements in the Lease.
https://www.sam.gov/SAM/
RLP NO. 36C24W26R0045, PAGE 11 GSA TEMPLATE R101WH (07/20/2026)
2. If the offered Space is located on the 1st floor of the warehouse Building AND is 10,000 rentable square feet or less in area, AND the top of proposed storage is 12 feet in height or less, the Offeror is not required to submit to GSA the Fire Protection and Life Safety (FPLS) Submittal Information listed in sub-paragraph 1. However, the Offeror must submit a valid Building Certificate of Occupancy (C of O) issued by the local jurisdiction. If the Building C of O is not available or the local jurisdiction does not issue a Building C of O, a report prepared by a licensed fire protection engineer with their assessment of the offered space regarding compliance with all applicable local Fire Protection and Life Safety related codes and ordinances.
3. If the offered space is located on the 1st floor of the warehouse building, AND if the Offeror provides a Building Certificate of Occupancy obtained under any edition of the IBC, AND the offered space meets or will meet all the Lease requirements with regard to Means of Egress, Automatic Fire Sprinkler System, and Fire Alarm System prior to occupancy, the Offeror is not required to submit to GSA the Fire Protection and Life Safety (FPLS) Submittal Information listed in sub-paragraph 1.
L. Legal Property Description and Tax ID. The legal description of the Property and tax ID number associated with the Property, copies of prior year tax notices and prior year tax bills, as well as any other information (such as a fact sheet, 5” wide x 3” high or larger color photograph, site plan, location map, and tax parcel map) in case of multiple tax parcels for an offered Building, or multiple buildings on a tax parcel, and any other information that may affect the assessed value, in order for the Government to perform a complete and adequate analysis of the offered Property. The Offeror is to provide a detailed overview and documentation of any Tax Abatements on the Property as outlined in the “Rea l Estate Tax Adjustment” paragraph of the Lease.
M. Parking Plan and Narrative. A plan and short narrative as necessary to explain how the Offeror will meet the parking requirements.
N. Architectural Plans for Building Modernization. The architectural plans for modernization, if the offered Building is not a modern office Building.
O. Scaled Floorplan of Offered Space(s). Computer generated plans set to 1/8" = 1'-0" (preferred meeting sub-paragraphs 1 through 5 noted below:
1. All plans submitted for consideration shall include floor plan(s) for which Space is being offered and floor plan(s) of the floor(s) of exit discharge (e.g., street level(s)).