Range Elevation and Details-Attachment C.pdf

PDF 195 KB Posted

Attached to
EOD Proficiency Range
Solicitation number
S-24800-00015594
Issued by
Oregon

About this file

This is an architectural elevation and details drawing prepared for the Minnesota Air National Guard's 148th Civil Engineering Squadron at Duluth Air Base, dated June 2010, in support of an EOD (Explosive Ordnance Disposal) Training Range project. The drawing, designated A1-02, provides technical specifications and construction details for a concrete structure designed to withstand blast effects. Key design elements include a 50-foot clear radius perimeter without vegetation (approximately 7,750 square feet), concrete footings poured on undisturbed soil with reinforcement specifications, masonry anchor bolts configured at four bolts per foot of wall, and multiple layers of compacted materials including washed sand and gravel. The structure incorporates drainage provisions with 4-inch PVC drains at the center of each side, directed to daylight at existing grade, and requires 6-inch minimum treated lumber protection on the blast-side of concrete walls.

The technical specifications detail reinforcement requirements including #4 rebar spaced at 10 inches horizontally and 18 inches vertically with minimum 3-inch cover for all steel, compaction standards using walk-behind vibrating plate equipment with three passes, and undisturbed native material or compacted granular fill extending 12 inches above existing grade. The drawing was prepared by designer Solberg, with review and approval by Trolson, Castleman, and Solberg. This detailed elevation and sectional information serves as guidance for contractors bidding on construction or modification work related to the EOD Training Range project, establishing the precise dimensional and material requirements necessary for the blast-resistant structure.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

sheet number

Minnesota Air National Guard 148th Civil Engineering

4630 Mustang Drive Duluth, Minnesota 55811 sheet title

ELEVATION &

DETAILS

A1-02

19'

33'-8"

4'

23'-8"

8'-10" 2"

8"

6'-6"

6'

1'-6"

3" 2'

4 - #4 REBAR EVENLY SPACED,

PROVIDE MIN 3" COVER FOR ALL

STEEL. POUR FOOTINGS ON

UNDISTURBED SOIL.

MIN.

2" X 12" TREATED

LUMBER ON "BLAST

SIDE" OF CONCRETE WALLS

50' CLEAR RADIUS

W/O VEGETATION

(APP. 7,750 SQ.FT)

MASONRY ANCHOR BOLTS 12" X 8"

4 ANCHOR BOLTS PER FOOT OF WALL

6"

UNDISTURBED NATIVE

MATERIAL OR COMPACTED

GRANULAR FILL

12" ABOVE EXIST. GRADE

#4 REBARS SPACED @ 10" HORIZONTALLY

& 18" VERTICALLY. PROVIDE MIN

3" COVER FOR ALL STEEL.

PROVIDE 6" OF GRAVEL MATERIAL

OVER FABRIC OVER EXISTING GRADE.

FEATHER TO EXISTING EXISTING ROAD

SURFACE.

6'

EXIST. GRADE

WASHED COMPACTED SAND

(COMPACTION, WALK BEHIND

VIBRATING PLATE 18" WIDE, 3

PASSES)

WASHED COMPACTED SAND

(COMPACTION, WALK BEHIND

VIBRATING PLATE 18" WIDE, 3

PASSES), SAN ONLY NO GRAVEL

2 2

4'

4" PVC

DRAIN @

CENTER

OF EACH

SIDE, DRAIN

TO DAYLIGHT

TO EXISTING

GRADE

project title

Scale:

Design file no:

Drawing code:

Date: JUNE 2010

Designer:

Drawn by:

Reviewed by:

Checked by:

Submitted by:

SOLBERG

TROLSON

CASTLEMAN

SOLBERG

SOLBERG

Revisions:

REV NO. REVISIONDATECATEGORY

EOD TRAINING

RANGE

BCE PN: 012014

AutoCAD SHX Text

AutoCAD SHX Text A1-02

AutoCAD SHX Text

DETAIL

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

AutoCAD SHX Text A1-02

AutoCAD SHX Text

SECTION

AutoCAD SHX Text

NOT TO SCALE

Sheets and Views
A1-02 24x36

File details come from the government source that posted it. Updated .