PWS Appendix 14 Confined Space Inventory JBER-R.pdf
PDF 86 KB Posted
- Solicitation number
- FA500020R0019
View the file
Other files
Show all 46
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
O rg an iz at io n
S ho p Ti tle
O ff ic e S ym bo l
U ni t A ss ig ne d
ID C
S P
T E va lu at io n D at e
Fa ci lit y
N um be r
R oo m N um be r
S pa ce
D es cr ip tio n
S pa ce im en si on s
E nt ry im en si on s
E ng ul fm en t
E nt ra pm en t
To xi ci ty
O xy ge n
D ef ic ie nc y
Fl am ab ili ty
C ur re nt
/P as t U se
A ct ua l/P ot en tia l
H az ar d
P er m it to ta ls
C la ss ifi ci at io n
(P er m it)
N on
-P er m it
To ta ls
C la ss ifi ca tio n (n on -P er m it)
N ot es
773 CES/CEOES BOMS Contractor Theater 9/10/2019 2 Auditorium Below Stage 25'x60' 3'x3' X X X Repairs Oxy. Deficiency/Electrical Exposures 1 Permit
773 CES/CEOES BOMS Contractor Chapel 9/9/2019 3 Boiler room Boiler room 20'x25'x5' deep
4'x5' Rectangle X X X Repairs
Oxy. Deficiency, Gas, Steam, CO, Tripping, Electrical, Hot water burns 1 Permit
773 CES/CEOES BOMS Contractor Battalion HQ 9/10/2019 618 Entire Building
Ceiling 3 foot crawl space
Entire Building X Repairs Entanglement 1 Permit Remove ceiling tiles for access
773 CES/CEOES BOMS Contractor Wilderness Inn 8/20/2019 647 Boiler room-crawl space
Crawl Space
20'x40'x4' tall 2'x2' X Repairs Oxy. Deficiency 1 Permit
773 CES/CEOES BOMS Contractor Wilderness Inn 8/20/2019 647 Above freezers
Air handler Room
Over 500 Sq Ft 3'x3' Repairs
Electrical exposure/moving equipment 1 Permit
773 CES/CEOES BOMS Contractor Gold Rush Inn 8/20/2019 655
Inside-above compu.
Room
Air handler Room 10'x15' 2'x2' Repairs
Electrical exposure/moving equipment/glycol burns 1 Permit
773 CES/CEOES BOMS Contractor MP Admin. 8/20/2019 656 Tunnels Mech room 20'x6'x5' high 3'x7' X X Repairs Electrical exposure 1 Permit
773 CES/CEOES BOMS Contractor Battalion HQ 9/10/2019 672
Ceiling 3 foot crawl space
Crawl Space
Entire Building 2'x2' X Repairs Entanglement 1 Permit
773 CES/CEOES BOMS Contractor Buckner PFC 8/26/2019 690 Tunnels
Mech System Tunnel
Entire Basement
From Mech Room X X Repairs Burns/Thermal hazards 1 Permit
773 CES/CEOES BOMS Contractor Vehicle Shed 8/28/2019 704 OWS Cellar Doors
Oil Water Separator 4.5'x4.5' 4'x4' X X X Repairs
Oxy. Deficiency/Chemical Hazard 1 Permit
773 CES/CEOES BOMS Contractor Boiler Out Bldg. 9/30/2019 722 Boiler area Boiler Pit 20' x 25' 3' x 3' X X X Repairs Oxy. Deficiency 1 Permit
773 CES/CEOES BOMS Contractor Laundry 9/8/2019 726 Basement Utilidor Rectangle Doors Repairs
Oxy. Deficiency/Thermal Hazard 1 Non-Permit
773 CES/CEOES BOMS Contractor Admin. 8/26/2019 730 Crawl space-tunnel
Crawl Space
Entire Building 3'x4' X X Repairs Thermal hazard 1 Permit
773 CES/CEOES BOMS Contractor Housing Maint.
Shop 8/28/2019 740
Outside- Drainage pit
Oil Water Separator 4.5'x4.5' 4'x4' X X X Repairs
Oxy. Deficiency/Chemical Hazard 1 Permit
773 CES/CEOES BOMS Contractor Vehicle Maint.
Shop 8/28/2019 750
Cellar doors oil water separator pit
Oil Water Separator 4'x4' 4'x4' X X X Repairs
Oxy. Deficiency/Chemical Hazard 1 Permit
773 CES/CEOES BOMS Contractor Vehicle Maint.
Shop 8/28/2019 756
Cellar doors oil water separator pit
Oil Water Separator 4'x4' 4'x4' X X X Repairs
Oxy. Deficiency/Chemical Hazard 1 Permit
773 CES/CEOES BOMS Contractor Vehicle Maint.
Shop 8/28/2019 778
Cellar doors oil water separator pit
Oil Water Separator 4'x4' 4'x4' X X X Repairs
Oxy. Deficiency/Chemical Hazard 1 Permit
773 CES/CEOES BOMS Contractor Vehicle Maint.
Shop 8/28/2019 784
Cellar doors oil water separator pit
Oil Water Separator 4'x4' 4'x4' X X X Repairs
Oxy. Deficiency/Chemical Hazard 1 Permit
773 CES/CEOES BOMS Contractor Vehicle Maint.
Shop 9/30/2019 798
Down stairs - Tunnel
Mech room tunnel 6'x6'x100' 6'x6' X Repairs
Entanglement/Thermal Hazard 1 Permit
773 CES/CEOES BOMS Contractor Engineering-Maint.
Shop 8/28/2019 974 Used oil pit
Oil Water Separator 6'x4' 4'x4' X X X Repairs
Oxy. Deficiency/Chemical Hazard 1 Permit
773 CES/CEOES BOMS Contractor Boiler Out Bldg. 9/9/2019 974A Pit Steam Line Pit
4'x4'x8' deep
4'x5' Rectangle X Repairs Steam Hazard 1 Permit
773 CES/CEOES BOMS Contractor Vehicle Maint.
Shop 8/28/2019 975
Oil Water Separator, Service pits
Oil Water Separator 4'x4' 4'x4' X X X Repairs
Oxy. Deficiency/Chemical Hazard 1 Permit
773 CES/CEOES BOMS Contractor Admin. Bldg. 8/26/2019 977 Pit-outside Sewer Cleanout 3'x3'8' deep 3'x3' X X Repairs Oxy. Deficiency 1 Permit
773 CES/CEOES BOMS Contractor Vehicle Maint.
Shop 8/28/2019 995 Steam Vault Steam Vault 4'x4' 3' Diameter X Repairs Steam Hazard 1 Permit
BOMS Contractor Compu. Training Facility 9/30/2019 47645
Boiler-room Pit-inside
Crawl Space
20'x40'x4' tall 2'x2' X Repairs Oxy. Deficiency 1 Non-Permit Monitor Atmosphere
Totals: 23 2