project-1-BACT Testing.pdf

PDF 199 KB Posted

Attached to
Repair Boiler Building 55350 and Plumbing Building 91249
Solicitation number
W9124A22R0012
Issued by

About this file

This document contains instructions for sampling and testing water for total coliform and E. coli bacteria. It outlines the proper procedures for collecting representative water samples, including using sterile sample bottles, removing aerators from taps, running water for several minutes before collecting, filling bottles without rinsing, keeping samples cool below 10 degrees Celsius, and delivering samples to an approved laboratory within 24 hours of collection.

The related federal contract opportunity is to repair Boiler Building 55350 and plumbing in Building 91249 for the Department of the Army Materiel Command Army Contracting Command located at Aberdeen Proving Ground.

View the file

Other files

File Type Posted
B08 Amedment 0001 Solicitation W9124A22R0012 (Released).pdf PDF
B08 Amedment 0001 Solicitation W9124A22R0012 (Conform Released).pdf PDF
project-1-Picture 13 Bldg 91249 Outside Ground.pdf PDF
project-1-picture 7 fourth floor Ladder.pdf PDF
project-1-Picture 11 outide wall of Bldg 91249 Leaders and Grounding.pdf PDF
B08 Solicitation W9124A22R0012 07-05-2022.pdf PDF
B08 Attachment 3 Wage Determination General Decision Number AZ20220023 06-10-2022 Building.pdf PDF
project-1-201809697-91249-historic asbestos testing.pdf PDF
project-1-201807524-91249-Tower-Cabin-Windows.pdf PDF
B08 Attachment 1-SOO-combined-HUAC-FEE18018-8J-Bldg-55350-HIO32505-8J-Bldg-91249-30-JUN-2022.docx DOCX document
project-1-Picture 12 Bldg 91249 outside water valve.pdf PDF
project-1-picture 1 first floor conduit.pdf PDF
project-1-picture 6 third floor overflow drain.pdf PDF
project-1-223-25-360 Flight Control Tower.pdf PDF
project-1-Fort Huachuca 91249 Floor 01.pdf PDF
project-1-91249-Sample-Plan-Tower-Cabin-Windows.pdf PDF
project-1-picture 2 first floor ladder and telecom cable.pdf PDF
project-1-Picture 12 Bldg 91249 outside water valve (1).pdf PDF
project-1-91249-SP-ACM-LBP-Ext-Ladder.doc DOC document
project-1-picture 10 Sixth floor Bathroom.pdf PDF
project-1-201804690-91249-WC-1st-Floor-Equip-Rm-Tower-Cabin.pdf PDF
project-1-Picture 8 Fourth Floor Valves.pdf PDF
project-1-Fort Huachuca 91249 Floor 03.pdf PDF
project-1-Fort Huachuca 91249 Floor 06.pdf PDF
B08 Attachment 2 Past Performance Evaluation Questionnaire.docx DOCX document
project-1-Fort Huachuca 91249 Floor 04.pdf PDF
project-1-Combined Photos a.pdf PDF
project-1-Picture 3 Second floor conduit.pdf PDF
project-1-201910012-C EMGS.pdf PDF
project-1-Fort Huachuca 91249 Floor 05.pdf PDF
project-1-picture 4 second floor dry transformer.pdf PDF
project-1-picture 9 Fifth Floor Kitchen.pdf PDF
project-1-Fort Huachuca 91249 Floor 02.pdf PDF
project-2-223-25-361 Electromagnetic Test Facility.pdf PDF
project-1-91248 Utility Site Plan-91248 AREA GAS SEWER WATER.pdf PDF
project-1-Picture 5 third floor Water Heater.pdf PDF
project-1-20-001 Bldg 91249 LAAF Control Tower Egress HIO14201-7J.pdf PDF
project-1-201609924-91249-tower-stairs-breakroom floor.pdf PDF
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Bac‐T Testing o In accordance with AR 200‐1 use of standard method 9221 B (Total Coliform) and 9221 F (Coliilert) o Samples taken in accordance with EPA Standards

Total coliform and E. coli (Escherichia coli) are used as indicator organisms for fecal or sewage contamination.

Detection of total coliform and E. coli in water, food or surfaces usually points to poor hygiene and possible presence of pathogenic organisms.

Proper procedures for collecting samples must be observed to ensure that the samples are representative of what is being tested, i.e., water, food or surfaces. A competent person shall perform sampling and deliver the samples to an approved Laboratory for testing.

To avoid unpredictable changes in the bacterial composition or concentration of the samples, analysis should be started as soon as possible after collection. The sample should be transported to the laboratory in a cooler containing ice or cooling packs. It is important that samples are protected from direct contact with the ice or cooling packs to prevent freezing during transport. If possible the interval between sample collection and the beginning of its analysis (i.e., holding time) should not exceed 24 hours. In remote areas, however, this may not be possible and up to 48 hours may be an accepted holding time. The implications of the extended holding time should be discussed with the laboratory.

Samples should be labelled so that they are easily identified. Complete the chain‐of‐custody form with the time, date, location, type of sample (e.g., raw water, building number/room number sink location), sampler’s name, and identification number, and any special instructions. If the holding time is more than 24 hours for whatever reason it is important to record the duration and temperature of storage, as this information should be taken into consideration when interpreting the results.

Instructions for sampling water for Total Coliform and Escherichia coli (E.coli) testing Proper sampling procedure is extremely important in obtaining accurate water testing results. It is recommend using the sample containers provided by the testing lab. Before you begin sampling, please read all of these instructions. Remember, do not remove the cap from the bottle until just before you are ready to sample.

1. Before collecting a sample for bacteriological analysis, you must first obtain a STERILE SAMPLE BOTTLE and the chain of custody.

2. Select a cold water tap that is used frequently, but avoid using the kitchen sink faucet if at all possible. If the sampling tap has a screen or an aerator, please remove it. If you are using an outside tap, disconnect any hoses or other attachments.

3. Run the cold water at a relatively high flow for 3 to 6 minutes to clear the line. Reduce the flow to a smooth‐flowing water stream so it doesn’t splash.

4. Carefully open the bottle, keeping hands away from the inside of the cap or the bottle rim. The white powder or tablet must remain in the bottle. DO NOT RINSE THE BOTTLE. Fill bottle to three‐quarters full. A minimum of 300 ml sample is required. If overfilled, DO NOT POUR OUT EXCESS.

5. Fill out the label attached to the bottle with the required information.

6. Complete the chain of custody form, fold it and put it in a plastic bag to prevent it from being damaged by the ice packs.

7. Your sample must be kept cool at all times and must be received by the laboratory within 24 hours (if possible) from the time of “collection”. All samples must be kept cold and brought to the laboratory in a cooler or on ice packs.

File details come from the government source that posted it. Updated .