project-1-201807524-91249-Tower-Cabin-Windows.pdf

PDF 162 KB Posted

Attached to
Repair Boiler Building 55350 and Plumbing Building 91249
Solicitation number
W9124A22R0012
Issued by

About this file

This document contains details for a federal solicitation to repair two buildings at an Army facility. The solicitation seeks bids to repair the boiler building numbered 55350 and the plumbing building numbered 91249 at an Army facility. The solicitation was issued by the Department of the Army Materiel Command Army Contracting Command located at Aberdeen Proving Ground. The solicitation provides few other details regarding the specific repair work required, pricing terms, response dates or other salient information.

View the file

Other files

File Type Posted
B08 Amedment 0001 Solicitation W9124A22R0012 (Released).pdf PDF
B08 Amedment 0001 Solicitation W9124A22R0012 (Conform Released).pdf PDF
project-1-Picture 13 Bldg 91249 Outside Ground.pdf PDF
project-1-picture 7 fourth floor Ladder.pdf PDF
project-1-Picture 11 outide wall of Bldg 91249 Leaders and Grounding.pdf PDF
B08 Solicitation W9124A22R0012 07-05-2022.pdf PDF
B08 Attachment 3 Wage Determination General Decision Number AZ20220023 06-10-2022 Building.pdf PDF
project-1-201809697-91249-historic asbestos testing.pdf PDF
B08 Attachment 1-SOO-combined-HUAC-FEE18018-8J-Bldg-55350-HIO32505-8J-Bldg-91249-30-JUN-2022.docx DOCX document
project-1-Picture 12 Bldg 91249 outside water valve.pdf PDF
project-1-picture 1 first floor conduit.pdf PDF
project-1-picture 6 third floor overflow drain.pdf PDF
project-1-223-25-360 Flight Control Tower.pdf PDF
project-1-Fort Huachuca 91249 Floor 01.pdf PDF
project-1-91249-Sample-Plan-Tower-Cabin-Windows.pdf PDF
project-1-picture 2 first floor ladder and telecom cable.pdf PDF
project-1-Picture 12 Bldg 91249 outside water valve (1).pdf PDF
project-1-91249-SP-ACM-LBP-Ext-Ladder.doc DOC document
project-1-picture 10 Sixth floor Bathroom.pdf PDF
project-1-201804690-91249-WC-1st-Floor-Equip-Rm-Tower-Cabin.pdf PDF
project-1-Picture 8 Fourth Floor Valves.pdf PDF
project-1-Fort Huachuca 91249 Floor 03.pdf PDF
project-1-Fort Huachuca 91249 Floor 06.pdf PDF
B08 Attachment 2 Past Performance Evaluation Questionnaire.docx DOCX document
project-1-BACT Testing.pdf PDF
project-1-Fort Huachuca 91249 Floor 04.pdf PDF
project-1-Combined Photos a.pdf PDF
project-1-Picture 3 Second floor conduit.pdf PDF
project-1-201910012-C EMGS.pdf PDF
project-1-Fort Huachuca 91249 Floor 05.pdf PDF
project-1-picture 4 second floor dry transformer.pdf PDF
project-1-picture 9 Fifth Floor Kitchen.pdf PDF
project-1-Fort Huachuca 91249 Floor 02.pdf PDF
project-2-223-25-361 Electromagnetic Test Facility.pdf PDF
project-1-91248 Utility Site Plan-91248 AREA GAS SEWER WATER.pdf PDF
project-1-Picture 5 third floor Water Heater.pdf PDF
project-1-20-001 Bldg 91249 LAAF Control Tower Egress HIO14201-7J.pdf PDF
project-1-201609924-91249-tower-stairs-breakroom floor.pdf PDF
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Client Job: 1-7395589 PO Number:91249

JobNumber: 201807524

Routing Number: -

# Samples: 2

PLMn

PLM The "New" Method; see below

Client:

Polarized Light Microscope (PLM) Analysis for Asbestos in Bulk Sample

Method and Analysis Information:

Each bulk sample is first dissected under a 7-30x magnification stereo-microscope. This examination is used to determine the general type of sample, how many and what type of layers it has, and initial estimates of fiber types and quantities. Second, liquid media mounts are made of each layer - such mounts may be of selected fibers (used solely for identification purposes) or may be representative of the layer as a whole (used for quantitation purposes). The mounts may be made in a synthetic Canadian balsam, one of several solvents, or in refractive index oils (media of known refractive index). Generally, a variety of different mounts are made: some optimized for fiber visibility, some optimized for fiber identification, and some optimized for fiber quantitation. The mounted slides are then examined at 50-400x magnification on a Nikon Labphot-pol microscope. Optical characteristics are used to identify each observed fiber type; the optical data are contained for each sample on its detail analysis sheet, attached.

Current EPA and NESHAP regulations designate a result of <=1 % asbestos as "negative" and >1 % asbestos as "positive". Samples containing layers that have been determined to be "positive" may have to be handled differently during a renovation or demolition than samples whose layers have been determined to be "negative."

The method of fiber identification and quantitation is the “Standard Operating Procedures for the Analysis of Asbestos in Bulk Samples using Polarized Light Microscopy”, Chapter 7 of the Quality Assurance and Management Manual. This SOP and its associated reporting have been designed to satisfy all requirements in both EPA Method 600/M4-82-020 (The Interim Method) and EPA Method 600/R-93/116 (The New Method). The Interim Method is the required method for AHERA (US EPA 40 CFR Pt. 763), but this method calls for the reporting of composited results of multi-layered samples that is no longer an acceptable reporting practice in most circumstances. Current EPA rules, such as NESHAP (US EPA 40 CFR Pt. 61), as well as NVLAP accreditation policies, call for separate reporting for each layer of multi-layered samples. The New Method contains the same procedures for identification and quantification of asbestos as does the Interim Method, except that multi-layered samples are reported to comply with the latest US

EPA rule. Fiberquant not only reports the asbestos content of each layer of multi-layered samples separately (satisfying current EPA and NVLAP reporting requirements), but Fiberquant also reports what percentage of the sample each layer comprises. Therefore, the results may be arithmetically composited to satisfy the reporting requirements of the Interim Method. The method of fiber quantitation is an estimation technique in which the analysts quantitation is routinely calibrated by reference quantitation standards, and which has been shown to be equivalent in precision and accuracy to point counting. Friability is estimated for the purposes of deciding when to point count. Friabilities determined in the field take precedence over those determined in the laboratory. Those sample layers which are friable and estimated by the analyst to contain <= 1% asbestos are point counted using 400 points. Such point counting is required by NESHAP (National Emission Standards for Hazardous Air Polutants, Nov. 1990) in order to rely on analytical results that are <= 1%. The coefficient of variation for the estimation quantitation technique is 100% in the range 0- 5%. This means that PLM analysis is not capable of conclusively determining whether a layer containing close to 1% asbestos is actually "positive" or

"negative". For this reason, Fiberquant refers to results where asbestos was detected but <= 1% as "borderline negative", and results where asbestos was >1 % but <= 2% as "borderline positive" to indicate the uncertainty in assigning a "positive" or "negative" label. In the sample summary, "ND" means that no asbestos was detected during the analysis. A "Tr" or "Trace" of asbestos reported is defined for our purposes as the detection of several asbestos fibers during the analysis; this level would be right at the limit of detection for the method. Trace is only reported on the analysis detail - in the summary a trace would be reported as <=1%. The limit of detection (the smallest % of asbestos that can be detected) varies greatly depending on the matrix in which the asbestos is found. As little as 0.001% asbestos can be detected in favorable samples, while detection in unfavorable samples may approach the detection limit of 1% stated in the method. During the analysis, the analyst, for Fiberquant identification purposes only, determines the "apparent sample type" and "apparent layer types." It must be emphasized that these types are only what is apparent. Often, different materials appear similar or identical after sampling, so the analyst may assign a type other than what was sampled.

Floor tiles present a special problem for PLM asbestos analysis. Floor tile can contain chrysotile fibers so thin that they cannot be resolved by optical methods. In such a case, we may observe a percentage of asbestos which is lower than the actual percentage, or not observe asbestos at all when some is present. For this reason, floor tiles reported as negative should be confirmed to be negative using transmission electron microscope

(TEM) analysis. Likewise, vermiculite insulation materials containing traces of asbestiform asbestos present a problem for routine PLM analysis - the amphiboles are sometimes present in trace amounts inhomogeneously distributed. For this reason, loose vermiculite samples reported as negative should be confirmed to contain no amphibole using hydroseparation techniques.

The samples were analyzed under the following ongoing quality assurance program: Blank samples are routinely analyzed to maintain contamination-free materials. Each analyst has at least a bachelor's degree in physical science, and has also completed extensive training specific to asbestos analysis for 1-3 months before being allowed to analyze client samples. Qualitative reference samples are routinely analyzed to assure that analysts can identify asbestos and asbestos-look-alike fibers. Quantitative reference samples are routinely analyzed to calibrate and characterize the

Method: EPA 600/R-93/116Rec: 8/17/2018

Report Date: 8/21/2018 Date Analyzed: 8/20/2018

Fiberquant Internal SOP:

EMCOR GOVERNMENT SVCS

CLARKSTON RD BLDG 30033

FT HUACHUCA, AZ

Office Phone: (520) 533-5906

FAX: (520) 533-3699

85613-0000

5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558

Fiberquant, Inc. Page 1 of 4

PLM Analysis Summary: Job Number: 201807524 1-7395589 estimation procedure. Microscope alignment is checked each day. Refractive index oils are calibrated at least quarterly. At least 10% of client samples are re-analyzed from scratch by a different analyst than the original, and any discrepancies are resolved for the sample and similar sample types before the results are reported. All quality checks performed for these samples were in control except as detailed in the "Analytical Notes" below. All analysts participate in interlab round robins and proficiency testing to assure competence. Fiberquant is accredited by NVLAP (Lab code #101031) for the analysis of bulk samples for asbestos using PLM. Accreditation does not imply endorsement by the EPA, any other United States governmental agency or any private agency or association. Each lab analysis refers only to the sample tested, and may not, due to the sampling process, be representative of the material sampled. This report may not be reproduced except in full, without the approval of Fiberquant Analytical

Services.

Job Analysis Notes:

Some results may have been calculated using client supplied data, such as volume or area sampled, for which Fiberquant assumes no liability for accuracy.

Sample Number Lab Number Apparent Sample Type * Positive Layer Yes or No

Layer Color Apparent Layer Type * Asbestos Results

Adhesive/caulk2018-07524- 191249-01 Positive Layer? NoSample # no asbestos detectedpaintblackLayer # 1 no asbestos detectedsealantgrayLayer # 2

Adhesive/caulk2018-07524- 291249-02 Positive Layer? NoSample # no asbestos detectedpaintoff-whiteLayer # 1 no asbestos detectedsealantbrownLayer # 2

* Apparent Sample Types and Apparent Layer Types are as they appeared to the analyst. Since many types of materials appear similar after sampling damage, the apparent type of material may not be the actual type of material.

5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558

Fiberquant, Inc. Page 2 of 4

PLM Analysis Details Job Number: 201807524 1-7395589

2018-07524- 191249-01 8/16/2018Lab Number Sample Sampled:

JCJAnalyzed By 8/20/2018

Homogeneous

Adhesive/caulk

No

RubberyOKAn?

2# Layers NoPos Layer?

Apparent Smp Type synthetic fiber (shr Fiber Identification:

Sample Analytical Note

Procedure: tweased apart using forceps. Procedure: dissolution of polymer matrix using solvent. Note: paint sample size was too small - analysis may not be representative of whole.

Fibers

Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per

Refractive Index Determinations synthetic fiber (shredded)

W A N N H + P

Non-Fibrous Components (in approx. decreasing order): polymer, filler, Condition:acceptable

Layers

# Layer Type % Color Friability

Percents of Each Fiber

Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6

1 0.5 n.d. - - - - -paint black 1

2 99.5 2-5% - - - - -sealant gray 1

100Total % 2-5% - - - - -Overall %

2018-07524- 291249-02 8/16/2018Lab Number Sample Sampled:

JCJAnalyzed By 8/20/2018

Homogeneous

Adhesive/caulk

No

RubberyOKAn?

2# Layers NoPos Layer?

Apparent Smp Type synthetic fiber (shr Fiber Identification:

Sample Analytical Note

Procedure: tweased apart using forceps. Procedure: dissolution of polymer matrix using solvent.

Fibers

Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per

Refractive Index Determinations synthetic fiber (shredded)

W A N N H + P

Non-Fibrous Components (in approx. decreasing order): polymer, filler, Condition:acceptable

Layers

# Layer Type % Color Friability

Percents of Each Fiber

Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6

1 1 n.d. - - - - -paint off-white 1

2 99 2-5% - - - - -sealant brown 1

100Total % 2-5% - - - - -Overall %

Fr=Friability: 1=very non-friable; 2= non-friable; 3=friable; 4=highly friable

Colors: B=black;BL=blue;BR=brown;CL=clear;G=Green;GY=gray;OR=orange;OW=off-white;PN=pink;PU=purple;R=red;TN=tan;W=white;Y=yellow;V=various

Fiber Morphology: A=fine fibers/bundles, white, sinewy, flexible; B=fine fibers/bundles, w-br, straight, broomed ends; C=fine fibers/bundles, blue, straight, broomed ends;

D=fine to coarse fibers, CL-B, brittle; E=coarse fibers,CL or dyed, striated; F=coarse fibers or splinters, W-BR, ribbon-like; G=lath-like or shards, low aspect ratio, may taper

Iso=isotropism - may be yes or no; Pleo=pleochroism - may be yes or no; Bi=birefringence - may be None, Low, Medium or High

Elg=sign of elongation - may be +, - or B (both); Ext=extinction - may be Parallel, Oblique, None or Undulating; Oil=medium used to for dispersion staining

Col Par=dispersion staining colors parallel to the fiber (fiber/halo): b/w=black/white; dg/py=dark gray/pale yellow; vg/y=violet gray/yellow; db/ly=dark blue/lemon yellow;

vb/g= vivid blue/gold; sb/o=sky blue/orange; pb/r=pale blue/red; gb/dr=gray blue/dark red; w/b=white/black. Col Perp=same only perpendicular to fiber.

RI Par=refractive index parallel to fiber; RI Perp=refractive index perpendicular to fiber

5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558

Fiberquant, Inc. Page 3 of 4

PLM Analysis Details Job Number: 201807524 1-7395589

21-Aug-18Analyst: JASON C. JEDINAK

Larry S. Pierce, Approved Accreditation Signatory

Printed:

21-Aug-18Original Print Date:

5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558

Fiberquant, Inc. Page 4 of 4

File details come from the government source that posted it. Updated .