Product Description for Exterior Dust Collection System_v2.docx

DOCX document 30 KB Posted

Attached to
AHEC DUST COLLECTION
Solicitation number
W91QF025QA015
Issued by

About this file

This document is a detailed Product Description for an Exterior Dust Collection System (EDCS) for the US Army Heritage and Education Center (USAHEC) fabrication shop. The system requires a wood dust collector capable of handling 3,895 CFM across 10 different woodworking machines, including a planer, jointer, band saw, sanders, chop saw, router table, table saw, and panel saw. The specification calls for a comprehensive dust collection solution that includes a wood dust collector similar to a 2500 Economy model, a single-zone spark detection and suppression system, rolled lip quickclamp ductwork, and a 12" gravity backdraft damper.

The procurement includes full installation services with electrical hookups, ducting installation, system startup, and onsite training. Additional requirements specify work during normal business hours (Monday-Friday, 0700-1630), obtaining Carlisle Barracks Department of Public Works permits, providing engineered and as-built drawings, constructing an 8' x 8' exterior concrete pad, and offering a 1-year warranty on parts. The solicitation is issued by the Department of the Army Materiel Command Mission and Installation Contracting Command at Fort Eustis, with the solicitation number W91QF025QA015, targeting compliance with International Building Code, National Electrical Code, International Mechanical Code, and National Fire Protection Association Code for combustible wood dust collection.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Purchase Description for USAHEC Exterior Dust Collection System (EDCS) USAHEC (Exhibit Fabrication Shop, Building 952) USAHEC is seeking to purchase an Exterior Dust Collection System (EDCS) that complies with International Building Code, National Electrical Code, International Mechanical Code and the National Fire Protection Association Code for collection combustible wood dust. The wood dust collection system will be connected to the following machines in USAHEC’s fabrication shop (building 952):

Item
Machine
Branch Duct Size
Estimated CFM
1
Planer
4”
350
2
Jointer
4”
350
3
Band Saw
(2) 4”
700
4
Wide Belt Sander
4”
350
5
Spindle Sander
4”
350
6
Belt/Disc Sander
4”
350
7
Chop Saw
5”
550
8
Router Table
4”
350
9
Table Saw
4”
350
10
Panel Saw
3”
195
Total CFM required to operate all machines simultaneously
3895

System Requirements:

1. Wood Dust Collector (Similar to 2500 Economy wood dust collection system with 10” 2500 CFM Blower, totally enclosed or similar model with like capacity)

2. Single Zone Spark Detection and Suppression/extinguishment System

3. All related plumbing and electrical hook ups

4. Rolled Lip, Quickclamp duct work

5. 12” gravity Backdraft Damper

6. Plumbing from Source to Suppression Nozzles Installation:

1. All related system installation, hook ups and materials to include, but not limited to:

a. Electrical hook up for collector and spark detection system

b. Wire up dust collector

c. Install all ducting and dust collector panel

d. Run wiring from dust collector panel top dust collector

e. Run 120 CV circuit for spark arrester panel

f. Wire alarm bell, siren and spark arresters

2. Provide onsite start up and balancing

a. Take airflow readings at connection to set and maintain proper velocity throughout the system

b. Provide onsite system training

c. Provide startup report to customer Additional Requirements:

1. Work will be done during normal business hours, Monday- Friday, 0700-1630. Work outside these hours require advance notice of 3 business days.

2. No work will be done on federal holidays.

All applicable:

1. Carlisle Barracks Department of Public Works approved permits, drawings and inspections

2. Engineered drawings including as built drawings upon completion

3. Electrical, hydraulic and air connections (wiring, piping, fittings)

4. Exterior concrete pad approximately 8’ x 8’, contractor is responsible for final measurements to meet code requirements

5. Freight, shipping and/or handling expenses

6. All necessary rental and lift equipment

7. 1 year Warranty on parts

8. Contractor will furnish all plant, material, and labor to install dust collection system in usable fashion in accordance with applicable codes and approval from Carlisle Barracks Department of Public Works.

File details come from the government source that posted it. Updated .