Attachment I RFP PR507071 Neptune Questions and Answers.pdf
PDF 54 KB Posted
- Solicitation number
- PR507071
- Issued by
-
Department of Energy
About this file
This is a Questions and Answers document for RFP PR507071 Neptune, issued by Oak Ridge National Laboratory (ORNL) on November 6, 2026. The document addresses six clarification questions regarding the Modular Hot Cell – Test Article Fabrication project, with the applicable Statement of Work confirmed as MHC-DS-SPEC-004-R0. Key technical clarifications include confirmation that the support stand shall be designed to QL-4 (Commercial Quality) standards to integrate with the Mechanical Cask Interface Assembly for testing and operation, while certain existing components are QL-3 rated. Regarding the flatness tolerance specification in Section B-B of .01 inches, ORNL confirmed that contractors may specify a regional application around the seal (such as 4 inches inward from the gasket groove to the plate edge) rather than applying it to the entire surface, provided this is documented via a seller deviation request form (Appendix C) post-award.
ORNL declined to provide several requested technical documents and drawings (MHC-AE-SPEC-115310, MHC-AE-SPEC-115311, and five specified drawings) prior to award, stating they are not required for proposal development but will be distributed post-award for reference purposes. Contractors are encouraged to submit specific information requests rather than broad document requests to obtain necessary details for proposal preparation. Additionally, ORNL indicated that foreign-national access restrictions regarding the SharePoint site, Controlled Unclassified Information, and export-control considerations for affiliated non-U.S. design resources are currently under review with the export control office and may impose restrictions on proposal development.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RFP PR507071 Neptune Questions and Answers – 11/6/2026
Question # Question ORNL Response 1 The RFP attachment list identifies the Statement of Work as MHC-DS-SPEC-005-R0, while the Quality Plan section of the RFP references MHC-DS-SPEC-004-R0. Can you confirm that 005 is the presiding SOW?
Confirmed. MHC-DS-SPEC-004-R0 Is the document number to the entire Modular Hot Cell – Test Article Fabrication SOW.
2 Section 3.4.2.1 of the SOW classifies the design as QL-4 (Commercial Quality), while Section 6 provides characteristic-verification guidance for QL-3. Could you confirm the applicable quality level for this effort?
Certain existing SSCs already designed are QL-3. The support stand shall be designed as QL-4 to integrate with the Mechanical Cask Interface Assembly allowing it to be tested and operated.
3 We anticipate using an affiliated non-U.S. design resource for a portion of the engineering and fabrication scope.
Could you clarify any restrictions on foreign-national access to the SharePoint site and Controlled Unclassified Information, and any export-control considerations we should account for?
This may be a point for restrictions and is currently under review with our export control office.
4 Request for the following documents: MHC-AE-SPEC- 115310
MHC-AE-SPEC-115311
The requested document package and associated specifications include information not required for the proposal development for this solicitation. If required post award they will distributed for reference only but, will not be shared at this time. If there is specific information missing that is driving you to these sections, please submit those individual questions and we will supply answers as soon as possible.
5 Request for the following drawings:
MMHC1SCHV08-P001
- MMHC1CAVE30-ASSY
- HMHC1SCHVAC-P003
- MMHC1CAVE00-P001
- MMHC1CAVE00-S300
- MMHC1CAVE00-S200
The requested document package and associated specifications include information not required for the proposal development for this solicitation. If required post award they will distributed for reference only but, will not be shared at this time. If there is specific information missing that is driving you to these sections, please submit those individual questions and we will supply answers as soon as possible
6 In the attached PDF extracted from the RFP, Section B-B specifies a flatness tolerance of .01. Does this tolerance apply to the whole surface indicated by datum A? Is it possible to instead specify a region around the seal that the flatness tolerance only applies to? E.g. 4 in. in from the gasket groove to the edge of the plate.
Yes it is possible to specify a region around the seal the flatness applies to. Please note this will need to be documented via seller deviation request form (Appendix C) post award.
File details come from the government source that posted it. Updated .