Poggio R-invent-BAAP_idraulica_fire suppression sys.xlsx

XLSX spreadsheet 21 KB Posted

Attached to
Testing and Inspection of Fire Suppression Systems for USAG-Italy Vicenza and Poggio Renatico (FE)
Solicitation number
W912PF24Q0080
Issued by

About this file

This document is an Excel spreadsheet that appears to contain information about the fire suppression systems in various rooms of a building in Poggio Renatico, Italy. The spreadsheet includes details such as the room number, type, and whether it has fire-rated doors, emergency exits, fire dampers, smoke/heat vents, fire extinguishers, hydrants, hose reels, sprinkler systems, and fire suppression systems. It provides specifics on the quantities, types, and weights of the fire suppression equipment in each room.

The related federal contract opportunity is a solicitation (W912PF24Q0080) for the testing and inspection of fire suppression systems for USAG-Italy facilities in Vicenza and Poggio Renatico. The Department of the Army Materiel Command Army Contracting Command is the issuing agency. The solicitation and related attachments provide the full details of the contract requirements.

View the file

Other files

File Type Posted
B08_24Q0080_AMD01_Released_20240617.pdf PDF
Poggio Renatico Site-inventario-elpro_elettrica_fire detection sys.xlsx XLSX spreadsheet
Longare-invent-BAAP_idraulica_fire suppression sys.xlsx XLSX spreadsheet
B08-SOL_W912PF24Q0080_Attachment2_SuitabilityKTR.pdf PDF
B08_SOL_W912PF24Q008_VI fire_RELEASED_20240528.pdf PDF
Report Example.xlsx XLSX spreadsheet
Longare Site-inventario_elettrica_fire detection sys.xlsx XLSX spreadsheet
Torri Site-inventario-elpro_elettrica_fire detection sys.xlsx XLSX spreadsheet
Lerino Site-inventario_elettrica_fire detection sys.xlsx XLSX spreadsheet
Del Din-invent_idraulica_fire suppression sys.xlsx XLSX spreadsheet
ASP7 Site-inventario_idraulica_fire suppression sys.xlsx XLSX spreadsheet
Ederle Site-inventario_elettrica_fire detection sys.xlsx XLSX spreadsheet
B08_SOL_W912PF24Q0080_ATTACHMENT 3_CERTIFICATION 52.222-56.pdf PDF
B08-SOL_W912PF24Q0080_Attachment1_Antimafia.pdf PDF
Ederle-invent_idraulica_fire suppression sys.xlsx XLSX spreadsheet
Del Din Site-inventario_elettrica_fire detection sys.xlsx XLSX spreadsheet
Villaggio-invent-BAAP_idraulica_fire suppression sys.xlsx XLSX spreadsheet
ASP7 Site-inventario_elettrica_fire detection sys.xlsx XLSX spreadsheet
Villaggio Site-inventario-elpro_elettrica_fire detection sys.xlsx XLSX spreadsheet
Torri-invent-BAAP_idraulica_fire suppression sys.xlsx XLSX spreadsheet
Lerino-invent-BAAP_idraulica_fire suppression sys.xlsx XLSX spreadsheet
Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Poggio Renatico (FE)

Room Number:
Numero della Stanza:Room Type:
Destinazione d'uso della stanza:False ceiling:
Controsoffitto:Raised floor:
Pavimento sopraelevato:Fire Rated Doors:
Porte tagliafuoco:Emergency exit:
Uscita di emergenza:Fire dampers:
Serrande tagliafuoco:Smoke and Heat Clearance Vents:
Evacuatori di fumo e calore:Fire extinguishers:
Estintori:Hydrants:
Idranti:Hose Reels:
Naspi:Sprinkler System:
Impianto di spegnimento ad acqua:Fire Suppression System:

Impianto di spegnimento a gas:

Q.tyREIpanic hwAlso emergencyQ.typanic hwQ.tyExtinguishing agentWeight [kg]classes
[#A #B etc.]n. headsn. heads in false ceilingsystem type
[W, D, M]n. headsn. cylindersWeight [kg]Extinguishing agent
Building:
Edificio:Floor:
Piano:Q.tàREImaniglioneAnche emergenzaQ.tàmaniglioneQ.tàEstinguentePeso [kg]classi
[#A #B etc.]n. ugellin. ugelli nel controsoffittotipo impianto [W, D, M]n. ugellin. bombolePeso [kg]Estinguente
1GF1BREAK RMYN----1N--1DRY CHEM14 lbsA-A-393---------
1GF-HALLWAY 1YN----1N---------------
1GF-HALLWAY 2YN----1N--2DRY CHEM14 lbsA-A-393---------
1GF2COMM RMYN---------------------
1GF3TOILETYN---------------------
1GF4LAUNDRYYN---------------------
1GF5TOILETYN---------------------
1GF6LOCKER RMYN---------------------
1GF7FITNESS RMYN---------------------
1GF8FITNESS RMYN---------------------
1GF9LOCKER RMYN---------------------
1GF10POST OFFICEYN---------------------
1GF11OFFICEYN---------------------
1GF12OFFICEYN---------------------
1GF13LOCKER RMYN---------------------
----3---3------------
-----3----3-ERROR:#VALUE!----------
2GF1CONFERENCE RMYN---------------------
2GF2OFFICEYN---------------------
2GF3OFFICEYN---------------------
2GF4COMPUTER RMYN---------------------
2GF5OFFICEYN---------------------
2GF6OFFICEYN---------------------
2GF7OFFICEYN---------------------
2GF8OFFICEYN---------------------
2GF9COMPUTER RMYN---------------------
2GF10STORAGEYN---------------------
2GF11TOILETYN---------------------
2GF12TOILETYN---------------------
2GF13SERVER RMYN----1Y--1CO25113B---------
2GF-HALLWAY 1YN----1N--1CO25113B---------
2GF-HALLWAY 2YN----1N--1POWDER634A 233B C---------
----3---3------------
-----3----3-ERROR:#VALUE!----------
3GF1STORAGEYN----1N---------------
3GF2TOILETYN---------------------
3GF3HALLWAYYN--------2POWDER634A 233B C---------
3GF4LOCKER RMYN---------------------
3GF5STORAGEYN---------------------
3GF6EMPTYYN---------------------
3GF7EMPTYYN---------------------
3GF8STORAGEYN----1N---------------
----2---2------------
-----2----2-ERROR:#VALUE!----------
generator roomGF1Locale GENN---------------------
---------------------
---------------------

TOTALS - - - - 8 - - - 8 - - - - - - - - - - - -

Consorzio ST - I°Sem. 2016/2017 &"Arial Black,Normale"&14&A

Pag. &P / &N

File details come from the government source that posted it. Updated .